Sierra Series 900 Single & Dual Channel System. Instruction Manual

Similar documents
Analox 1000 Series. User Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

Sierra Model 951 Digital Flo-Box. Instruction Manual Part Number IM-951 Revision A 09-05

Model 4001 Series Single Channel Controller

Pioneer-R16 Gas Monitor Operator s Manual

CP CP

MODEL 8143 SIGNAL SELECTOR INSTALLATION AND OPERATION MANUAL

OPERATION & MAINTENANCE MANUAL GUARDIAN SPACE PRESSURE MONITOR WITH REMOTE AUXILLARY ALARM

Rectifier RC-series. Manual RC-series English MA doc. Manual Wall and 19 English

Instruction Manual WARNING

GTA 4100R. Dual Processor, Dual Channel Controller Card. Part Number R. Manual Revision v6.30 (updated 10 November 2009)

ABOUT THIS DOCUMENT AND THE DOCUMENT STRUCTURE WE USE

Modus Model DA General Eastern Low Differential Pressure Alarm Controller

HALOGUARD IR MULTI-POINT, COMPOUND SPECIFIC MONITOR INSTRUCTION MANUAL

MAINTENANCE & TROUBLESHOOTING GUIDE LEAK ALARM CHANNEL DRY OIL WATER AUX ALARM HIGH LOW CRITICAL WATER TANK LEVEL ALARM MODEL LDE-740 ADVANCE PAPER

Flopurge TS. Operation Manual

OG5000 Ozone Generator Model OG5000B-A. User Manual

Greentrol Automation, Inc.

Across-the-Line SERIES MP300 Combined Manual and Automatic

ESSEX ENGINEERING CORPORATION

Automatic Humidity Controller. Model 512 (Revision C) Operating Manual

Table of Contents SECTION PAGE SECTION 1 INTRODUCTION Description Features Models... SECTION 2 RS-232 COMMUNICATIONS...

S/601 Controller Installation Manual

Revision: None DCN No. First Issue Date: November 30, 1998 Product: Standard DCT, 120-volts

tcm100, tcm101 Series Temperature Control Modules and PTS100, PTS100/3 Pipe Temperature Sensors Operations Manual

User s Manual. TIGER S EYE E-Series Mark V Jockey. TIGERFLOW Systems, Inc Mint Way Dallas, Texas

STATUS ALARM ALARM HISTORY POWER HISTORY RESET

Controllers. Instruction Manual WARNING

DICKSON KT6 DICKSON. Temperature Chart Recorder. Specifications. Product. Display Symbols. Information & Operating. Contents:

Rev Pulse Modulating Anti- Sweat Control (PMAC II) Installation and Operation Manual

Datasheet: K-22 LO Sensor

Soft Start Series MP700 Solid State, Reduced Voltage

STATUS ALARM HISTORY ALARM RESET

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

Installing the Cisco ONS FAP-4 Fuse Alarm Panel

ACSI MODEL 1410 POWER SUPPLY INSTALLATION INSTRUCTIONS

Float Battery Chargers Unfiltered SCR and Filtered SCRF Series Single Phase Input / Three Phase Input

ph COOLING TOWER CONTROLLER

Table of Contents SECTION PAGE

4100U City and Relay Cards Installation Instructions

INSTRUCTION MANUAL and DETAILED PRODUCT SPECIFICATION TRIPLEX PUMP CONTROL SYSTEM MODEL NUMBER CPC-3. M336 Rev F. November 21, 2000.

ACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F

INTRODUCTION / TABLE OF CONTENTS

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

Axiom Technologies L.L.C Telephone: Pennbright Dr., Suite 220 Fax: XP7 USER S MANUAL

Flow Level Pressure Temperature. Rugged tactile response keys. Try the all new Fluidwell Configurator at:

SERIES VAC Microprocessor-Based Direct Spark Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION. Export Information (USA)

EKC 347 Liquid Level Controller REFRIGERATION AND AIR CONDITIONING. Manual

Pump-Up Controller MODEL 4062

HALOGUARD TM IR MONITOR (OPTIONAL) FOUR or EIGHT POINT SCANNER INSTRUCTION MANUAL

Carbon Monoxide Transmitter

DIESEL ENGINE CONTROL UNIT DCU USER S MANUAL - N-2000 Lillestrøm, Norway Tel: (+47) Fax: (+47)

English. Series. Installation and Use Manual

Analog Room Pressure Monitor RPC Series

LC2200 Level Controller Installation and Maintenance Instructions

D3000. Installation & Setup Guide

Public Safety DAS Annunciator Panel

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

GasScanner 4C. Four Channel Monitor. Operator s Manual. MINT-0280-XX Rev. A 02/25/08

Web Site: Forums: forums.parallax.com Sales: Technical:

OVEN INDUSTRIES, INC.

Software Version 2.01 LEVEL MONITOR MODEL 220

Pump-Down Controller MODEL 4052

Speed and Frequency Seite 1 von 7

Table of Contents. Page Quick Set-up Instructions 1. Theory of Operation 2. Specifications 3. TM 1003W Controls and Connections 4

MODEL 5100 VOTING LOGIC MODULE

RK Carbon Monoxide Transmitter Operator s Manual

Thermo Scientific Ramsey TM Series Sensing Speed Conditions on Rotating Shafts and Machinery

ANALOX SENSOR TECHNOLOGY LTD ANALOX DD1101 INSTALLATION & OPERATION MANUAL

RE-PR3-E-27 3-Phase Panel Mount 27kW

Instructions Oxygen Controller R8471C 2.1 8/

Securitron Magnalock Corporation S. 51 st St., Ste. 102 Phoenix, AZ Phone: (800) MAGLOCK

ENERGY LIGHT USER S GUIDE ENERGY LIGHT USER S GUIDE

Web Site: Forums: forums.parallax.com Sales: Technical:

Instructions R8471J Gas Controller for use with Model OPECL Open Path Eclipse IR Gas Detector 1.1 1/

Series DCT1000DC Dust Collector Timer Controller Specifications Installation and Operating Instructions

Eldex Column Heater. Operator s Manual

PS6 SERIES. Installation PS6 SERIES. Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option

SCR/SCRF SERIES. Industry s First Choice for Time-Tested Proven Reliability FLOAT BATTERY CHARGERS. Single-Phase Input

Sentry LIQUID LEVEL GAUGE MODEL 200 or 200C OWNER MANUAL REV 1.7 SEPT08 PAGE 1 OF 12

AC300WR 300 WATT REDUNDANT HF-20A CHASSIS POWER SUPPLY/SYSTEM MONITOR TECHNICAL MANUAL

APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES

MODEL 8144-RD CLOCK SELECTOR/DISTRIBUTION AMPLIFIER INSTRUCTION MANUAL. SPECTRACOM CORPORATION 95 Methodist Hill Drive, Suite 500 Rochester, NY 14623

ECO N DATE DESCRIPTION OF CHANGE CHG

Ramsey Series Motion Monitoring Systems Accurate Sensing of Speed Conditions on Rotating Shafts and Machinery

MS-4012/4024 and CMS-4012/4024. Instruction Manual for the. Fire Alarm Control Panels

B-40/B-41 Modulating Temperature Controller

Beacon 110 Gas Monitor Operator s Manual

RKA-LEL Sample Draw Combustible Gas Detector

1040 Gas Monitor INSTALLATION AND OPERATING INSTRUCTIONS AMC-1040 WITH INTEGRAL ELECTROCHEMICAL SENSOR

Model OEM-2 INSTRUCTIONS FOR USE

Ethernet General Purpose

Instruction Manual Model L2 RF Switch

STATUS ALARM ALARM HISTORY POWER HISTORY RESET

WM3000 WIRELESS MODULES

Revision November 2013 JVA Technologies. Ethernet General Purpose IO Technical Manual

Flostop TS D7E and A8E. Operation Manual

DC200 Digital Dispenser Operating Manual

S AFETY SYSTEMS TECHNOLOGY Mill Creek Drive, Suite 215 Laguna Hills, California 92653, USA Tel (949) Fax (909)

Mark 25 Ultrapure Water Conductivity Analyzer

Transcription:

Series 240/24 Instruction Manual Table of Contents Sierra Series 900 Single & Dual Channel System Instruction Manual Part Number IM-90-07/05 Revision D. 5 Harris Court, Building L Monterey, CA 93940 (83) 373-0200 (800) 866-0200 Fax (83) 373-4402 http://www.sierrainstruments.com Sierra Instruments b.v. Bolstoen 30A 046 AV Amsterdam The Netherlands +3(0)20-64580 Fax +3(0)20-64585 IM-24-C 0-

CUSTOMER CAUTION RE: OXYGEN SERVICE Sierra Instruments, Inc., is not liable for any damage or personal injury, whatsoever, resulting from the use of Sierra Instruments mass flow meters or controllers for oxygen gas. Although Sierra cleans its mass flow meters and controllers prior to shipment, we make no claim or warranty that their cleanliness renders them safe for oxygen service. The customer must clean Sierra Instruments mass flow meters or controllers to the degree required for the customer s oxygen flow applications. COPYRIGHT SIERRA INSTRUMENTS 994 No part of this publication may be copied or distributed, transmitted, transcribed, stored in a retrieval system, or translated into any human or computer language, in any form or by any means, electronic, mechanical, manual, or otherwise, or disclosed to third parties without the express written permission of Sierra Instruments. The information contained in this manual is subject to change without notice. TRADEMARKS Side-Trak TM and Flo-Box TM are trademarks of Sierra Instruments Inc. Page 6

. Introduction... 2. Locating System Electronics... 2 TABLE OF CONTENTS 3. Front Panel Functions... 3 3. Channel Selection... 3 3.2 Reading Flow Value... 3 3.3 Flow Setpoint Display and Adjustment... 3 3.4 High/Low Alarm Display and Adjustment... 3 3.5 Totalize (Mass Flow Integration) Function... 4 3.5 3.5. Reset Totalize Function... 4 4. Rear Panel Connections... 5 4. Power Line and Fuse... 5 4.2 20-Pin Connectors for Sierra Flow Meters/Controllers... 5 4.3 26-Pin I/O Connector... 5 4.4 4.3. Flow Value Output 0-5 VDC and 4-20 ma... 5 4.4 4.3.2 Valve Off/Purge/Monitor... 5 4.4 4.3.3 High/Low Flow Alarm Outputs... 6 4.4 Automatic/Manual Setpoint Selection... 6 5. Maintenance... 7 5. Display Adjustment... 7 5.2 Zen and Span Adjusted... 7 5.3 Factory Service... 7 Appendix A: Specifications... 8 Appendix B: Back Panel Connector, 20-Pin... 9 Appendix C: Back Panel Connector, 26-Pin...0 Appendix D: Alarms for System Electronics... Appendix E: Wiring Guide...2 Appendix F: Ratio Control Option...3 Page 5

The Sierra Instruments, Inc. Single and Dual Channel System Electronics is a highly integrated systems solution to flow measurement and control. INTRODUCTION One or two independent flow meters or controllers can be operated simultaneously. Linear operation with LCD readout is standard. The back panel connectors provide outputs of 0-5 VDC and 4-20 ma and are 0-00% analogs of the flow range. Both voltage and current outputs are simultaneously available. Flow setpoint for flow controllers is from either the front panel adjustment potentiometers or a remote source via the back panel I/O interface. These potentiometers are only available on system electronics which have a C as part of the model number (i.e., 902C). Side-Trak mass flow controllers also incorporate valve purge/ monitor/off functions which are accessible from the back panel I/O connector. Each channel has an optional high and/or low alarm (open collector) output. The alarm adjustment pots are located inside the system electronics box and can be read on the front panel display during adjustment. An optional built-in totalizer on single channel configurations displays the total mass flow. The electronic totalizer is highly immune to power line interruptions. The power supply is a linear (non-switching) laboratory quality unit capable of easily supplying power to 2 channels simultaneously. Page

The System Electronics should be located in a room-temperature location which is dry and dust-free. Use cable lengths in accordance with the guidelines given with your transducer. Excessive cable lengths will impair operation of both the System Electronics and the transducer. 2 LOCATING SYSTEM ELECTRONICS Extremes of temperature and direct sunlight should be avoided. Choose a location which allows the readout to be easily viewed. Page 2

System Electronics s front panel controls provide ease of operation. To get the most benefit from a Sierra Instruments, Inc. System Electronics, read these instructions before attempting operation. On dual channel units, the rotary switch labeled Channel Select determines which channel is displayed. 3 FRONT PANEL FUNCTIONS 3. Channel Selection The flow value is normally read from the LCD Display. Readout is usually in engineering units and is indicated on the label. 3.2 Reading Flow Value System Electronics toggles between flow reading and flow setpoint by the switch labeled SET/READ. When in the READ mode, the display shows flow value as above. When in the SET mode, the display shows the current setpoint value in the same units as the READ mode. 3.3 Flow Setpoint Display and Adjustment (Controllers Only) For each channel, there is an optional high alarm and/or low alarm. Each alarm output is active whenever the flow is above or below the preset value, respectively. All alarm outputs are OPEN COLLECTOR NPN and sink current to COMMON. If driving a relay, a reverse polarity protection diode must be connected across the coil. See appendix D for additional information regarding the alarms. 3.4 High/Low Alarm Display and Adjustment When the flow is below the low alarm set value, the low alarm is active. (Alarm is ON). When the flow value is greater than the high alarm set value, the high alarm is active. (Alarm is ON). The alarm adjustments are located internally. The front bezel must first be removed by unscrewing the four black screws holding it in place, then sliding the top cover out to expose the main printed circuit board. See the drawing in Appendix G giving the location of the alarm component. The alarm display is activated using internal switches. These switches are located near the front panel. The switch labeled ALM or NORM shows the alarm setting on the front panel display. The toggle switch labeled HI/LO selects whether the high or low alarm is displayed. This switch must be held at the ALM position while adjusting the alarm point with the switch in the ALM position, the LCD display will show the alarm value. The alarm adjustment potentiometers are located toward the rear of the main PCB. As you face the front of the unit, Channel is on the right and Channel 2 is on the left. The high alarm pots are marked R29 and the low alarm pots are marked R33. Page 3

As the potentiometer is rotated the appropriate alarm setpoint is varied from zero to the full scale flow value and displayed in the front LCD display. The totalize option records the total mass flow. This value is indicated on the front panel electronic counter and is therefore immune to power line interruptions. 3.5 Totalize (Mass Flow Integration) Function Counter has battery back-up that uses two.5 alkaline N size cells. The totalizer reading may be reset to all zeros by depressing the button next to the totalizer display window. 3.5. Reset Totalize Function Page 4

The AC power line connector (or power entry module) is located on the back panel. A cordset is supplied with the System Electronics and is compatible with wall outlets in the USA. Be sure System Electronics is wired for the proper power mains voltage, either 5 VAC, 60 Hz or 230 VAC, 50/60 Hz, as indicated on the label. If you wish to change the receptacle configuration, you may use any standard CEEE 22 cordset to accomplish this. The fuse is an integral part of the AC power connector. To remove the fuse, turn the front panel power switch OFF then remove the cordset from the back panel power connector. With the cordset removed, a small door built into the back panel power connector can now be flipped out exposing the fuse holder. In USA System Electronics there is a single gray fuse holder which can be unclipped and pulled out by hand. The fuse is an AGC type 3 amp rating. Replacement fuses are widely available. 4 REAR PANEL CONNECTIONS 4. Power Line and Fuse The back panel has two 20-pin headers labeled Channel and Channel 2. Each channel is set-up for a specific transducer. Be sure that the serial number on the side of the transducer agrees with the rear panel label. Normally, cables are prewired and the entire system is set-up at the factory. Pin assignments are given in Appendix B. 4.2 20-Pin Connectors for Sierra Flow Meters/Controllers CAUTION! Do not plug a transducer into the wrong channel, as flow values may be extremely inaccurate and/or damage may result to system electronics and transducer. The 26-Pin I/O Connector on the back panel is the means to access many of the System Electronics functions such as flow outputs, valve override and monitoring, etc. The following section covers these functions in detail. Refer to Appendix B for pin assignments. 4.3 26-Pin I/O Connector The 26-pin I/O connector provides two analog outputs for each channel. One provides a 0-5 VDC LINEAR analog of the flow value referred to common. The other supplies a 4-20 ma LINEAR analog of the flow value referred to +5 VDC. Both outputs are always present for all channels. Refer to Appendix B for pin assignments. 4.3. Flow Value Output 0-5 VDC and 4-20 ma The 26-pin I/O connector has connections for Side-Trak controller systems to drive the valve fully closed or fully open. Also, the voltage across the valve may be monitored to help in valve adjustment. If the VALVE OFF pin for a channel is connected to common, the valve is closed regardless of setpoint. This pin is TTL compatible. Refer to Appendix C for pin assignments. 4.3.2 Valve Off/Purge/Monitor (Side-Trak Controllers Only) Page 5

The VALVE PURGE function is activated by the VALVE TP (test point) pin. When this pin is connected to common, the valve is fully open regardless of setpoint. This pin must source 50 ma of current when driven to common. If a voltmeter is connected between this pin and 5 VDC, the voltage across the valve coil may be read. Refer to Appendix C for pin assignment. The 26-pin connector has two optional alarm outputs per channel. One is active when the flow drops below a preset value (low alarm). The other is active when the flow increases above a preset value (high alarm). All alarm outputs are open collector. Maximum current is 00 ma per alarm. Maximum standoff voltage is 30 VDC. 4.3.3 High/Low Flow Alarm Outputs CAUTION! If a relay is being driven by an alarm, A protection diode must be connected across the relay coil with reversed polarity. A high and low alarm may be connected in parallel to make a window alarm. Whenever the flow is inside of the window defined by the two alarms, the alarm is inactive (OFF). If the flow is outside of the window, the alarm is active (ON). See Appendix D for suggested alarm configurations. There are two plastic programming jumpers plugged into a header on the back panel. For each channel they determine whether the 0-5 VDC setpoint input comes from the front panel pots (MANUAL) or from the 26-pin I/O connector (AUTOMATIC). These jumpers are easily changed in the field simply by unpluging them and moving them to the other position. The system will not function as a control box for mass flow controllers without these jumpers. 4.4 Automatic/Manual Setpoint Selection (Controllers) Page 6

Normally each System Electronics is carefully set-up at Sierra Instruments and needs no maintenance. Individual transducers may need periodic maintenance. Refer to transducer manuals for the proper procedure. 5 MAINTENANCE The full scale value of the display can be adjusted using the Display Adjustment Potentiometers, R49 for Channel and R48 for Channel 2. To adjust the span valve of the display, connect a precision 5 VDC input to pin 3 or a 20 ma input to pin 9 on the 20 pin connector for the appropriate channel. Adjust the corresponding potentiometer to change the span to the desired full scale value. 5. Display Adjustment The location of the decimal point can be changed using jumpers located at J5 J7. There is one set of jumper connectors for each channel. The following identifies the jumper number and decimal point location: J 7 digit (xx,x) J 6 2 digit (x,xx) J 5 3 digit (,xxx) The Zen and Span Adjustment Potentiometers (R2 and R6) are factory adjustments used to set the individual meter to the system electronics. Sierra recommends that these potentiometers not be adjusted in the field. Consult with Sierra s Customer Service Department at (408) 373-0200 for assistance. 5.2 Zen and Span Adjusted In the unlikely event of System Electronics malfunction, please contact our sales engineers or customer service at (800) 866-0200 outside California, or (408) 373-0200 inside California. Ship all systems to: 5.3 Factory Service Sierra Instruments, Inc. 5 Harris Court, Bldg. L Monterey, CA 93940 Attention: Service Department Be sure to include complete return shipping instructions. IT IS NOT POSSIBLE TO DELIVER PARCELS TO A POST OF- FICE BOX. In order to minimize the possibility of damage in shipment, the system should be shipped in its original packing carton. If the original carton is not available, follow this packing procedure: ) place bail in front of the unit to protect the front panel; 2) leave rear panel header latches open; 3) pad all sides. Page 7

GENERAL System Electronics Powers/Reads up to two transducers. Flow, Setpoint, High Alarm, and Low Alarm directly displayed in engineering units. (Linear models). Outputs 0-5 volts and 4-20 ma for each channel. Valve control functions of Close/Purge/Monitor. Built-in 0 turn precision setpoint potentiometers. Totalizers (optional) mass flow. APPENDIX A Specifications INPUT POWER 5 VAC ± 0% 230 VAC ± 0% (optional) OUTPUT POWER +5 VDC @.25 A 5 VDC @.90 A OUTPUT HUM AND NOISE Less than.05 Volts RMS AMBIENT TEMPERATURE RANGE At full rated power: 0-45 C. At half rated power: 0-60 C. RELATIVE HUMIDITY 0-50% non-condensing DISPLAY 3 2 digit LCD in engineering units or 0-00% analog. CONTROLS Power ON/OFF. Channel Select (two channel configurations). Total mass flow reset (with totalizer only). One or two precision 0 turn Setpoint pots as required (for controllers only). INPUTS 0-5 VDC and 4-20 ma for each channel (jumper selected on PCB). OUTPUTS 0-5 VDC and 4-20 ma for each channel. 0-5 VDC is referred to common. 4-20 ma is referred to +5 VDC. ALARMS (Optional) Low Alarm and High Alarm open collector output for each channel. Able to sink 00 ma to common. Stand-off voltage 30 VDC. Independently set by internal pushbuttons/pots. Uses front panel display to show alarm points. TOTALIZER Totalizer has 6-digit capacity. DIMENSIONS 3"H x 9"W x "D (without rack mounting ears) WEIGHT 7 pounds Page 8

KEY A B C D E F G H I J APPENDIX B Back Panel Connector Pin Assignments; 20-Pin Transducer Connector 2 3 4 5 6 7 8 9 0 (View of connector from back of enclosure) PIN NO. FUNCTION PIN NO. FUNCTION A Setpoint Output to Chassis Ground Controllers 2 Common B Common 3 0-5 Volt Signal from C Common Transducer D Valve Test Point 4 +5 VDC Supply from (Avail. I/O Connector) System Electronics to Transducers E RED Connection (Factory Use Only) 5 BLACK Connection (Factory Use Only) F 5 VDC supply from System Electronics 6 No Connection to Transducers 7 No Connection G No Connection 8 +5 VDC Supply from H High Alarm Output System Electronics to (Avail. I/O Connector) Transducers I Low Alarm Output 9 4-20 ma Signal from (Avail. I/O Connector) Transducer J Valve Off 0 Common (Avail. I/O Connector) Page 9

KEY A B C D E F G H I J K L M APPENDIX C Back Panel Connector Pin Assignments; 26-Pin I/O Connector 2 3 4 5 6 7 8 9 0 2 3 (View of connector from back of enclosure) PIN NO. FUNCTION PIN NO. FUNCTION A Channel, 0-5 Volt Common Linear Output 2 Common B Channel 2, 0-5 Volt Linear Output 3 Common C Channel, Automatic 4 Common Setpoint Input D Channel 2, Automatic 5 Channel Valve Test Setpoint Input Point E Channel, 4-20 ma 6 Channel 2 Valve Test Linear Output Point F Channel 2, 4-20 ma Linear 7 5 Power Supply Output 8 5 Power Supply G +5 VDC Power Supply 9 Channel Valve Off H +5 VDC Power Supply Input I Common 0 Channel 2 Valve Off Input J Common Channel 2 Totalizer K Channel Totalizer (pulse train output) (pulse train output) 2 Channel Low Alarm L Channel High Alarm Output Output (open collector) 3 Channel 2 Low Alarm M Channel 2 High Alarm Output Output Page 0

The alarms are a normally, open collector transistor outputs; that is, a transistor is used as a switch to ground. A High alarm means that if the flow signal is higher than the alarm trip setting, the transistor will be turned on. Conversely, a Low alarm activates the transistor when the flow signal is lower than the alarm trip setting. Sierra products usually incorporate a means of configuring the output as either a high alarm or low alarm. System Boxes contain both. APPENDIX D Alarms for System Electronics It is necessary to limit the current flow through the transistor to 00 ma maximum. The Standoff Voltage is set at 30 VDC. This means that the transistor can safely withstand 30 VDC on it s collector while in the off state. Voltages greater than this may cause failure of the transistor. (See Section 3.4 for specific instructhe alarm levels.) Following are several examples of commonly used alarm circuits: Relay Interface +5 +5 00mA MAX Alarm Out common Optional External Power Supply +5 23456789023456 NO NC COM PS Window Alarm Alarm output: LED will light if either high or low alarm is activated to indicate flow is outside preset high and low limits. High Alarm Low Alarm +5 K LED Alarm on actuates relay Simple Indicator Light Isolated Open Collector Output +5 LED K +5 MOC8020 Note: See IM for Back Panel Connection & Pin Numbers. Page

APPENDIX E Wiring Guide Page 2

Ratio Control Option Appendix F The constant ratio-control option ( -RC in the model code), provides the user with the ability to set and maintain an exact ratio of gas flow between two (or more) mass flow controllers (MFCs). The control box accomplishes this by scaling the setpoint to the slave controller(s) from the output of the master controller. Thus, even though the ratio can be initially set up without flow, actual operation of the slaves will not occur until a gas flow is established through the master. If the master inadvertently stops flowing (the gas runs out), the slave(s) will close. Thus this feature provides a constant ratio control when gas is flowing correctly, and a safety shut off for the slaves if the master gas runs out.. Channel one is typically set up as the master channel and should be cabled to the master controller (see the label on the control box to confirm that channel one matches the range of the master controller) 2. Channel two is typically set up as a slave channel (the channel that you want to follow the master) and should be cabled to the slave controller. If more than one slave is being used, additional channels may be set up at the factory. (It is convenient but not necessary to scale the slave channel(s) in percentage rather than actual engineering units) 3. With the front-panel switch in the Normal position, each channel of the box will function independently to supply command signals to the separate controllers. In the Ratio position, channel one will be the master and the slave channel(s) will follow the lead of the master, using its output signal to establish a setpoint(s). 4. If the constant-ratio feature is to be activated: a. Begin with the front panel switch in the Normal position. (Flow is not needed at this point though it can be done with or without it the controllers don t even need to be connected to the cables) b. Switch the channel dial to channel two (the slave channel). Calculate the percentage at which you want this slave controller to follow the master. With the Set/Read switch in the set position, dial in the flow that corresponds to this percentage. Example #: The master is scaled for a flow of 0-350, and the slave is also scaled for 0-350. You desire to have the slave follow the master at a 00% flow ratio. In Normal mode, switch the Set/Read to Set and dial in a setpoint of 350 to channel two (it makes no difference what channel one is doing at this point). Since the two controllers are scaled the same, they will always flow the same rate. Example #2: If you desire channel two to follow the master at a ratio of 30%, set channel two to 05 (30% of it s full scale range). Example #3: The master is scaled for a flow of 0-350, and channel two scaled for percentage (0-00). If you desire channel two to follow the master at 65% of the slave s capacity, set channel two to 65. Example #4: Master channel scaled for 0-350, slave scaled for 0-200. You want the slave to follow at 40% of its own capacity. In Normal mode, set channel two to 0.4 X 200, or 80. Now, when the master is flowing 350, the slave will flow 80, and when the master is reduced to a flow of 75, the slave will reduce to a flow of 40. c. Switch the Normal/Ratio switch to Ratio. Now, your ratio feature is scaled and the box is ready to use for a constant ratio application.

d. Turn off the power switch on the front of the box, attach the cables and the controllers (if you haven t already done so), and turn the power on. e. Apply gas pressure to the inlet of the controllers per the operating pressure listed on the labels. f. Box settings: Set/Read to Set, Normal/Ratio to Ratio, Channel knob to Channel (the master channel), and the jumpers (on the back of the box) in the Manual position. g. Dial in the desired flow to control the master controller. The slave(s) will follow at the preset ratio. To see the flows, switch the Set/Read switch to Read and monitor channel one and channel two, confirming that the slave is following the master at the pre-set ratio.