AMVM97 (B) / ACVM97 (B)

Similar documents
GCVC96 (B) Two-Stage, Variable-Speed ECM Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

GCVC96 (B) Two-Stage, Variable-Speed ECM Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

GMVC96 (B) Two-Stage, Variable-Speed ECM Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

ComfortNet -Compatible

GMSS96 / GCSS96. Single-Stage, Multi-Speed Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

GMSS96 / GCSS96 Single-Stage Multi-Speed Gas Furnace

GMSS96 / GCSS96. Single-Stage, Multi-Speed Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

GMSS92 / GCSS92. Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE. Heating Input: 40, ,000 BTU/h

GMSS92 / GCSS92. Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE. Heating Input: 40, ,000 BTU/h

GME8. Two-Stage Convertible, Multi-Speed ECM Gas Furnace 80% AFUE. Heating Input: 60, ,000 BTU/h

GMH95/GCH9 MULTI-POSITION, DUAL$AVER CONVERTIBLE, MULTI-SPEED GAS FURNACE

GMVC96. Two-Stage, Variable-Speed ECM Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

ADSH8. Two-Stage Convertible. Heating Input: 40, ,000 BTU/h

DM80HE. Two-Stage Convertible Multi-Speed ECM Gas Furnace 80% AFUE. Heating Input: 60, ,000 BTU/h

TECHNICAL MANUAL. GMH95 40" 95% Gas Furnace

GME8 80% AFUE. Multi-Position, TwinComfort. Heating Input: 60, ,000 BTU/h

80% AFUE. Multi-Position, Dual$aver. Heating Input: 70, ,000 BTU/h

TECHNICAL MANUAL. ADVC8/AMVC8 GMVC8 80% Gas Furnace Units

TECHNICAL MANUAL. ADVC8/AMVC8 GMVC8 80% Gas Furnace Units

GMS95 GAS $AVER PRODUCT SPECIFICATIONS 95% AFUE. Multi-Position, Single-Stage/Multi-Speed Gas Furnace. Heating Capacity: 46, ,000 BTUH

GMS9/GCS9 SERIES 93% AFUE

TECHNICAL MANUAL. ACVC9/AMVC95 GCVC9/GMVC95 90% UP TO 96% Gas Furnace Units

ACNF Series Ceiling-Mount Air Handlers 1½ to 2½ Tons

AVPTC. Air Handler 1½ to 5 Tons

GKS9 40" 90% Gas Furnaces

AVPTC. Air Handlers 1½ to 5 Tons

TECHNICAL MANUAL. AMS8 33-3/8" Gas Furnace Units 80% AFUE, Single Stage, Multi-Speed, Upflow Horizontal

ASUF Series. Multi-Position, Multi-Speed ECM-Based Air Handler 1½ to 5 Tons. Contents. Product Features

AVPTC. Multi-Position, Variable-Speed ECM Based Air Handler with Internal TXV ComfortNet Compatible 1½ to 5 Tons. Contents.

MBVC. Variable-Speed, ComfortNet - Compatible Modular Blowers. Cooling Capacity: 18,000-60,000 BTU/h

AVPTC Multi-Position, Internal Txv

DVPVC. Multi-Position, Variable-Speed Air Handler. Comfortnet - Compatible ECM-based Inverter-tuned Internal TXV

H9MPV. 2- Stage Variable Speed 90. Flexibility. Quality. Comfort. Efficiency. Service (7/2004)

TECHNICAL MANUAL. GMS8 33-3/8" Gas Furnace Units 80% AFUE, Single Stage, Multi-Speed, Upflow Horizontal

T9MPV. 2- Stage Variable Speed 90. Flexibility. Comfort. Efficiency. Quality. Service (05/2006)

AVPTC Multi-Position, Internal Txv

FG7T (C and L Series)

MBVC. Multi-Position, Variable-Speed ECM-Based, Modular Blower ComfortNet Compatible. Contents. Product Features

ARPT Series. Multi-Position. 2 to 5 Tons. Internal TXV, Multi-Speed PSC Motor

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS

Series Two- Stage Multi-position Gas Furnaces. Ruud Achiever Plus. R96T- Series 96% A.F.U.E. * Input Rates from 40 to 115 kbtu [11.72 to 33.

AVPTC Multi-Position, Internal Txv

ASUF Series. Multi-Position. Air Handler 1½ to 5 Tons

TECHNICAL MANUAL. GMS8 33-3/8" 80% Gas Furnace Units 80% AFUE, Single Stage, Multi-Speed, Upflow Horizontal

DVPEC. Multi-Position, Variable-Speed air handler. Comfortnet Compatible ECM-based Internal EEV, Inverter-tuned 2 to 5 Tons

TECHNICAL GUIDE. Acclimate MODELS: FL9S GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW SINGLE STAGE FURNACES 92% AFUE

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace

VNE GAS FURNACE 2- STAGE VARIABLE SPEED UPFLOW/HORIZONTAL

TECHNICAL MANUAL. GMH8 39" 80% Gas Furnace 80% AFUE, 2-Stage (Convertible), Multi-Speed, Upflow/Horizontal

Technical Information

LRP14HP/LRP14DF/LRP14AC/LRP14GE/LRP16GE/LRP16HP SERIES UNITS

AEPF. 1½ to 5 Tons. Contents Nomenclature... 2 Product Specifications... 3 Dimensions... 4 Wiring Diagram... 6 Accessories... 7

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama ! WARNING

TECHNICAL SPECIFICATIONS

Upflow/Horizontal Left Downflow/Horizontal Right Condensing, Direct Vent Gas-Fired Furnace FREEDOM 90 SINGLE STAGE

T9MPV SmartComfort VS90 Product Specifications

TZ96MDP SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to kw] (All Models 96% A.F.U.E. )

Wt. Lbs Model Number (BTUH) Hz

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace

TECHNICAL SPECIFICATIONS

TZ96MDV SERIES Model with Input Rates from 60 to 100 kbtu [17.58 to kw] (All Models 95% A.F.U.E. )

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH S9V2B080U4-SUB-1-EN. February 2016 S9V2B080U4PSAA TAG:

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 40,000 BTUH S9V2B040U3-SUB-1-EN. February 2016 S9V2B040U3PSAA TAG:

ASUF Series. Multi-Position. Air Handler 1½ to 5 Tons

RG7D 1-Stage Heat Series

MULTI POSITION GAS FURNACE

SLP98UHV WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

KG6TE Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

80% Variable Speed, Two Stage Heating Furnace. Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa)

W92P- SERIES Models with Input Rates from 40 to 115 kbtu [11.72 to kw] (92% A.F.U.E. )

XC80 TUD2B060ACV32A TUD2B080ACV32A TUD2C080ACV42A TUD2B100ACV32A TUD2C100ACV52A TUD2D120ACV52A TUD2D140ACV52A

FG6T(C,L) Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

Submittal. Downflow Two Stage Condensing Gas Fired Furnace 100,000 BTUH S9V2C100D4-SUB-1-EN. March 2016 S9V2C100D4PSAA TAG:

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH S9V2B080U3-SUB-1-EN. February 2016 S9V2B080U3PSAA TAG:

Cooling Capacity CFM in. w.c. (125 Pa)

TZ95MSX SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to kw] (All Models 95% A.F.U.E. )

TECHNICAL INFORMATION MANUAL

Rheem Classic Series Multi-position Gas Furnaces

ARPT Series. Multi-Position. 1½ to 5 Tons. Internal TXV, Multi-Speed PSC Motor

ACNF Series. Ceiling-Mounted Air Handlers 1½ to 2½ Tons

Rheem Prestige Series Communicating Two-Stage Variable Speed Upflow/Horizontal Gas Furnace

Multi-Position Gas Furnaces

Downflow/Horizontal Condensing, Gas-Fired Furnace XB 90 PUB. NO

Upflow/Horizontal Condensing, Gas-Fired Furnace XB 90 PUB. NO

TSTAT0101SC Recommended (order separately)

Rheem Classic Plus Series Two Stage Multi position Gas Furnaces

Ruud Achiever Plus Series Multi-position Gas Furnaces

MULTI POSITION GAS FURNACE

FORM NO. G REV. 4 Supersedes Form No. G Rev. 3

Rheem Prestige Series Communicating Two Stage Variable Speed Multi position. Gas Furnaces

Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace XR 80

G71MPP WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

GAS FURNACES. Communicating Furnace Thermostat. FORM NO. G Supersedes Form No. G RHC-TST550CMMS MID HIGH

TECHNICAL GUIDE MODELS: P*DH GAS-FIRED CONDENSING / HIGH EFFICIENCY DOWNFLOW / HORIZONTAL FURNACES 91 AFUE DESCRIPTION WARRANTY FEATURES

KG6RC Series TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

Upflow/Horizontal 2-Stage, Communicating Variable Speed Gas Furnace Platinum SV

TECHNICAL GUIDE SINGLE PIECE VARIABLE SPEED AIR HANDLERS DESCRIPTION FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS FEATURE MODELS: AVG24 THRU 60*(C)

TSTAT0101SC Recommended. Cooling Capacity CFM in. w.c. (125 Pa)

Transcription:

(B) / (B) Heating Input: 60,000 0,000 BTU/h Modulating, Variable-Speed EM Gas Furnace Up to 98% AFUE ontents Nomenclature... Product Specifications... Dimensions... 4 flow Specifications... 6 Wiring Diagram... Accessories... Standard Features Integrated communicating omfortbridge Technology ommissioning and diagnostics via on board Bluetooth with the oolloud phone and tablet application Heavy-duty stainless-steel tubular heat exchanger Stainless-steel secondary heat exchanger Self-calibrating modulating gas valve auto-configure for each installation Durable Silicon Nitride igniter Quiet variable-speed induced draft blower Self-diagnostic control board with constant memory fault code history output to a dual 7-segment display olor-coded low-voltage terminals with provisions for electronic air cleaner Efficient and quiet variable-speed airflow system gently ramps up or down according to heating or cooling demand Multiple continuous fan speed options offer quiet air circulation Auto-omfort and enhanced dehumidification modes available All models comply with alifornia 40 ng/j Low x emissions standard For installation in alifornia s South oast Quality Management District (SAQMD) only: This furnace does not meet the SAQMD Rule 4 ng/j x emission limit, and thus is subject to a mitigation fee of up to $40. This furnace is not eligible for the SAQMD lean Furnace Rebate Program: www.leanfurnacerebate.com. abinet Features Designed for multi-position installation: : upflow, horizontal left or right : downflow, horizontal left or right ertified for direct vent (-pipe) or non-direct vent (-pipe) Easy-to-install top venting with optional side venting onvenient left or right connection for gas and electrical service abinet air leakage (QLeak) % Heavy-gauge steel cabinet with durable finish Fully insulated heat exchanger and blower section tight solid bottom or side return with easy-cut tabs for effortless removal in bottom air-inlet applications * omplete warranty details available from your local dealer or at www.amana-hac.com. To receive the Lifetime Heat Exchanger Limited Warranty, the Lifetime Unit Replacement Limited Warranty (in both cases good for as long as you own your home), and the 0-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is not required in alifornia or Québec. SS- www.amana-hac.com /8 Amana is a trademark of Maytag orporation or its related companies and used under license to Goodman ompany, L.P., Houston, Texas. Supersedes 9/8

Nomenclature A M V M 97 060 B N ** 4,6 7,8,9 0,4 Brand A - Amana Brand Engineering Major / Minor Revisions * Not used for inventory control. onfiguration x M - Upflow/Horizontal N - Low x - Downflow/Horizontal abinet Width Motor B - 7½ - " V - Variable Speed EM/omfortBridge D - 4½" E - Multi-Speed EM S - Single Speed Maximum - 800 4-600 Gas Valve - 00-000 M - Modulating - Two- Stage MBTU/h S - Single Stage 060-60,000 BTU/h 080-80,000 BTU/h AFUE 00-00,000 BTU/h 97-97% AFUE 96-96% AFUE 0-0,000 BTU/h 9-9% AFUE www.amana-hac.com SS-

Product Specifications 0804NB 00NB 0DNB 0804NB 00NB Heating Data High Fire Input¹ 60,000 80,000 80,000 00,000 0,000 60,000 80,000 80,000 00,000 High Fire Output¹ 8,800 77,600 78,400 97,000 6,400 8,00 77,600 77,600 97,000 Low-Fire Steady-State Input¹ 0,000 40,000 40,000 0,000 60,000 0,000 40,000 40,000 0,000 Low-Fire Steady-State Output¹ 9,400 8,800 9,00 48,00 8,00 9,00 8,800 8,800 48,00 AFUE² 98 97 98 97 97 97 97 97 97 Temperature Rise Range ( F) - 6 0-60 - - 6-6 - 6-6 - 6-6 Vent Diameter³ " - " " - " " - " " - " " - " " - " " - " " - " " - " No. of Burners 4 4 6 4 4 irculator Blower Available A @ 0." ESP. -. -. - 4 - -. -. -. - 4 - Size (D x W) " x 8" " x 8" " x 0" " x 0" " x " " x 8" " x 8" " x 0" " x 0" Horsepower @ 07 RPM ½ ½ ¾ ½ ½ ¾ Speed VS EM VS EM VS EM VS EM VS EM VS EM VS EM VS EM VS EM Electrical Data Min. ircuit Ampacity⁴ 8.8 8.8.6.4.4 8.8 8.8.6.4 Max. Overcurrent Device (amps)⁵ 0 0 0 Shipping Weight (lbs) 8 4 44 7 7 44 46 ¹ Natural Gas BTU/h ² DOE AFUE based upon Isolated ombustion System (IS) ³ Installer must supply one or two PV pipes: one for combustion air (optional) and one for the flue outlet (required). Vent pipe must be either " or " in diameter, depending upon furnace input, number of elbows, length of run and installation ( or pipes). The optional ombustion Pipe is dependent on installation/code requirements and must be " or " diameter PV. ⁴ Minimum ircuit Ampacity = (. x irculator Blower Amps) + ID Blower amps. Wire size should be determined in accordance with National Electrical odes. Extensive wire runs will require larger wire sizes. ⁵ Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size. May use fuses or HAR-type circuit breakers of the same size as noted. Notes All furnaces are manufactured for use on VA, 60 Hz, single-phase electrical supply. Gas Service onnection ½" FPT Important: Size fuses and wires properly and make electrical connections in accordance with the National Electrical ode and/or all existing local codes. For bottom return: Failure to unfold flanges may reduce airflow by up to 8%. This could result in performance and noise issues. For servicing or cleaning, a 4" front clearance is required. Unit connections (electrical, flue and drain) may necessitate greater clearances than the minimum clearances listed above. In all cases, accessibility clearance must take precedence over clearances from the enclosure where accessibility clearances are greater. SS- www.amana-hac.com

Dimensions 8¾ Intake " Pipe Left-Side Drain Trap Exterior Holes 6½ ¾ ⅝ enter Dimple For Alternate Intake Pipe " OD Hole High-Voltage Standard Gas Supply Location A B ⅞ ¾ ¾ Vent/ Flue Pipe " PV Right-Side Drain Trap Exterior Holes High-Voltage Alternate Gas Supply 6½ 9½ Alternate Vent/ Flue Location ¾ 4½ 4 ½ 9¼ 9⅝ 4⅞ ⅞ 6½ ⅛ 9⅝ 9¼ ⅜ LEFT SIDE VIEW Low-voltage ⅞ ⅜ ½ ondensate Drain Trap Exterior onnection (Right or Left Side) ¾ PV FRONT VIEW D Unfolded Flanges E Folded Flanges ⅞ Low-Voltage ⅞ ⅜ ½ RIGHT SIDE VIEW Unfolded Flanges ½ Folded Flanges Model W D H A B D E Return 7½" 8⅞" 4½" 7½" 6" ⅞" ⅛" ⅝" 7½" 8⅞" 4½" 7½" 6" ⅞" ⅛" ⅝" 0804NB " 8⅞" 4½" " 9½" 7⅞" 6" 7½" 00NB " 8⅞" 4½" " 9½" 7⅞" 6" 7½" 0DNB 4½" 8⅞" 4½" 4½" " 0⅞" 9⅜" 0⅞" Minimum learances to ombustible Materials Position Sides Rear Front Bottom Flue Top Upflow 0" 0" " 0" " Horizontal 6" 0" " 0" 6" = If placed on combustible floor, the floor MUST be wood ONLY. 4 www.amana-hac.com SS-

Dimensions ½ 8¼ Vent/Flue Pipe " PV 6½ ½ B Return Intake Pipe PV ⅝ ⅜ Top View ⅝ ⅞ A B ⅝ ½ ⅞ 6½ 8¼ Alternate Vent/ ½ Low-Voltage 4 Low-Voltage Alternate Gas High-Voltage 4½ ⅛ Alternate Gas Supply 4¾ ⅛ 4⅞ 4¾ 4⅛ 6⅞ ⅜ ⅜ 6⅞ Drain Trap Holes Standard Drain Trap 8¾ ½ ½ D Unfolded Flanges E Folded Flanges Front View High-Voltage ⅝ Right Side Exterior Drain Trap Holes 8⅛ Unfolded Flanges 0⅛ Folded Flanges Right-Side View Return Model W D H A B D E 7½" 8⅞" 4½" 7½" 4⅝" 4" 4½" ⅝" 7½" 8⅞" 4½" 7½" 4⅝" 4" 4½" ⅝" 0804NB " 8⅞" 4½" " 8⅛" 7½" 8" 9½" 00NB " 8⅞" 4½" " 8⅛" 7½" 8" 9½" Minimum learances to ombustible Materials Position Sides Rear Front Bottom Flue Top Downflow 0" 0" " N 0" " Horizontal 6" 0" " 0" 6" = If placed on combustible floor, the floor MUST be wood ONLY. N = For installation on non-combustible floors only. A combustible floor sub-base must be used for installations on combustible flooring. SS- www.amana-hac.com

flow Data MODEL/TEMP RISE RANGE (MID RISE) * -6 (40) * 0-60 (4) 0804NB* - (40) 00NB* -6 (0) 0DNB* -6 (0) RISE RISE RISE RISE RISE Recommended cfm for 00% firing rate & expected temperature rise Lowest recommended cfm for 00% firing rate & expected temperature rise Maximum cfm for 00% firing rate & expected temperature rise 07 0 440 0 760 4 780 0 90 80 6 00 60 0 80 6 670 6 400 9 60 44 760 4 00 4 00 49 TE: Low Heat = High Heat X.7. Low Heat Temperature Rise Is Expected to Equal High Heat Temparatue Rise ± % 040F040-A * ooling Speed * ooling Speed. 600 40. 600 40 800 60 800 60. 000 700. 000 700 00 840 00 840 MAX,400 MAX,60 0804NB* ooling Speed 00NB* ooling Speed 800 60 800 60. 000 700 00 840 00 840 4 600 0 4 600 0 000 400 MAX,760 MAX,00 0DNB* ooling Speed 800 60 00 840 4 600 0 000 400 MAX,00 All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed. For most jobs, about 400 per ton when cooling is desirable. Do not operate above. w.c. ESP in heating mode. Operating between. and.8 w.c. is tabulated for cooling purposes only. Minimum Filter Sizes 0804NB 00NB 0DNB Filter Sizes (in²) (Qty) () 6 x (side or bottom) () 0 x (bottom) or () 6 x (side) Note: Other size filters of equal or greater dimensions may be used. Filters may also be centrally located. 6 www.amana-hac.com SS-

flow Data MODEL/TEMP RISE RANGE (MID RISE) * -6 (40) * -6 (0) 0804NB* -6 (0) 00NB* -6 (0) RISE RISE RISE RISE Recommended cfm for 00% firing rate & expected temperature rise Lowest recommended cfm for 00% firing rate & expected temperature rise Maximum cfm for00% firing rate & expected temperature rise 080 0 440 0 40 0 800 0 80 6 00 6 00 6 80 6 400 8 0 46 760 4 00 4 TE: Low Heat = High Heat X.7. Low Heat Temperature Rise Is Expected to Equal High Heat Temparatue Rise ± % 040F040-A * ooling Speed * ooling Speed. 600 40. 600 40 800 60 800 60. 000 700. 000 700 00 840 00 840 MAX,400 MAX,60 0804NB* ooling Speed 00NB* ooling Speed 800 60 800 60. 000 700 00 840 00 840 4 600 0 4 600 0 000 400 MAX,760 MAX,00 All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed. For most jobs, about 400 per ton when cooling is desirable. Do not operate above. w.c. ESP in heating mode. Operating between. and.8 w.c. is tabulated for cooling purposes only. Minimum Filter Sizes Filter Sizes (in²) (Qty) () 0 x 0 or () 6 x (top return) 0804NB 00NB () 4 x 0 or () 0 x (top return) Note: Other size filters of equal or greater dimensions may be used. Filters may also be centrally located. SS- www.amana-hac.com 7

Temperature Rise Range hart 00 90 80 70 60 0 40 0 0 0 BTU BTU/h OUTT Output vs TEMPERATURE Vs. Temperature RISE Rise hart HART 600 700 800 900 000 00 00 400 600 800 000 00 400 FMULAS BTU BTU/h OUTT Output = = x.08 x x Rise RISE RISE Rise = = Formulas BTU BTU/H OUTT Output.08 x.08 0 40 0 60 70 80 90 00 0 0 0 40 0 OUTT Output BTU/h BTU/HR x,000 x 000 TEMPERATURE Temperature Rise RISE 8 www.amana-hac.com SS-

Wiring Diagram TES: YL HOT SURFAE IGNITER IRUIT ONNET MODULATING GAS VALVE (ITERODGERS) YL LOW FIRE PRESSUR E SWITH 0 7 4 AUTO RESET AUXILIARY LIMIT ONTROL 4 8 FS 9 6 EA TWO-STAGE INTEGRATED ONTROL MODULE. SET HEAT ANTIIPAT ON ROOM THERMOSTAT AT 0.7 AMPS.. MANUFATURER'S SPEIFIED REPLAEMENT PARTS MUST BE USED EN SERVIING.. IF ANY OF THE IGINAL WIRE AS SUPPLIED WITH THE FURNAE MUST BE REPLAED, IT MUST BE REPLAED WITH WIRING MATERIAL HAVING A TEMPERATURE RATING OF AT LEAST 0$. USE OPPER ONDUTS ONLY. 4. UNIT MUST BE PERMANENTLY GROUNDED AND ONFM TO N.E.. AND LOAL ODES. 4 4 GR MANUAL RESET ROLLOUT LIMIT ONTROLS (SINGLE ONTROL ON 40 kbtu) AUTO RESET PRIMARY LIMIT ONTROL BURNER OMPARTMENT OWER OMPARTMENT EM MTR HARNESS AUX IN AUX OUT FUSE A 4 RR IRULAT OWER ID OWER TWO-STAGE PRESSURE SWITH ASSEMY HIGH FIRE PRESSURE SWITH FRONT OVER PRESSURE SWITH. TO REALL THE LAST 6 FAULTS, MOST REENT TO LEAST REENT, DEPRESS SWITH F ME THAN SEONDS ILE IN STANDBY ( THERMOSTAT INTS) U V W DATA A EAK OFF TABS 6. HUMIDIFIER INSTALLATION OPTIONS: USE HUM TERMINAL TO RUN HUMIDIFIER DURING HEAT ALL (OMMUNIATING LEGAY MODES). USE HUM-IN AND HUM-OUT TERMINALS TO RUN HUMIDIFIER DURING HEAT ALL ( OMMUNIATING MODE LEGAY MODE) INDEPENDENTLY FROM HEAT ALL (OMMUNIATING MODE ONLY - SETUP IS DONE WITHIN OMMUNIATING THERMOSTAT) TERM BIAS BIAS GN YL TX RX VDD R TX RX TR MV TH LINE R TERM BIAS INDUED DRAFT OWER GN T EAK OFF TABS BIAS YL MOB_PE IGN -N IND -N IND -LO IND -HI IGN LEFT ENTER RIGHT STATUS ODE RAT NA SAT R G W Y DH Y 40 VA INDUT OIL (ON SOME MODELS) YL TRANSFMER FLAME SENS 4 VA VA HASSIS GROUND GN JUNTION BOX OWER OMPARTMENT DO SWITH (OPEN EN DO OPEN) WARNING: DISONNET POWER BEFE SERVIING. WIRING TO UNIT MUST BE PROPERLY POLARIZED AND GROUNDED. INTEGRATED ONTROL MODULE 4V THERMOSTAT ONNETIONS TO VA/ Ø /60 HZ POWER SUPPLY WITH OVERURRENT PROTETION DEVIE R Y W G TO R FUSE A TO MIRO TO MIRO DO SWITH INDUT OIL (ON SOME MODELS) LINE HUM-OUT LINE HUM EA TO +VD (6) HUM-IN IGN FS TH (4) AUTO RESET AUXILIARY LIMIT ONTROLS HLO (0) PSO (7) PS () PS () () TR () HIGH FIRE PRESS. SWTIH (4) + VD () RX () TX () INTEGRATED ONTROL MODULE OL ODES: LOW VOLTAGE (4V) PINK OWN LOW VOLTAGE FIELD ITE HI VOLTAGE (V) UE GRAY HI VOLTAGE FIELD RED YL YELLOW JUNTION ANGE TERMINAL RPLE INTERNAL TO GN GREEN INTEGRATED ONTROL AK PLUG ONNETION GR DISONNET () () L JUNTION BOX INDO AIR IRULAT WR ELETRONI AIR LEANER TO VA/ Ø /60 HZ POWER SUPPLY WITH OVERURRENT PROTETION DEVIE L N ID WR HOT SURFAE IGNITER FLAME SENS VA 4 VA WARNING:DISONNET POWER BEFE SERVIING. WIRING TO UNIT MUST BE PROPERLY POLARIZED AND GROUNDED. INDO AIR IRULAT WR N 40 VA TRANSFMER MANUAL RESET ROLLOUT LIMIT ONTROLS FRONT OVER PRESSURE SWITH FIELD FIELD SPLIE DISONNET EQUIPMENT SWITH (TEMP.) IGNITER SWITH (PRESS.) OVERURRENT PROT. DEVIE AUTO RESET PRIMARY LIMIT ONTROL LOW FIRE PRESS. SWITH 4 GAS VALVE INTEGRATED ONTROL MODULE High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. Wiring is subject to change. Always refer to the wiring diagram on the Warning unit for the most up-to-date wiring. 040F048-A SS- www.amana-hac.com 9

Accessories Model Description 0804NB 00NB VENT- oncentric Vent Kit (") VENT- oncentric Vent Kit (") RF0004 Drain Kit -Horizontal Left Vertical Flue EFR0 External Filter Rack with 6 x Permanent Filter 070K00000S Flush Mount Vent Kit - " or " 070K0000S Flush Mount Vent Kit - " AFE8-60A Fossil Fuel (Dual Fuel) Kit LPLP0 Low LP Gas Pressure Switch LPM-0 LP onversion Kits HAMFK-0 High Altitude Kit Notes Indicates available for this model For installation in anada, gas furnaces are certified only to 4,00'. 0DNB Model Description 0804NB VENT- oncentric Vent Kit (") VENT- oncentric Vent Kit (") FSB7 Downflow Sub-Base 7." --- --- FSB Downflow Sub-Base " --- --- 070K00000S Flush Mount Vent Kit - " or " 070K0000S Flush Mount Vent Kit - " AFE8-60A Fossil Fuel (Dual Fuel) Kit LPLP0 Low LP Gas Pressure Switch LPM-0 LP onversion Kits HAMFK-0 High Altitude Kit Notes Indicates available for this model For installation in anada, gas furnaces are certified only to 4,00'. 00NB Amana is a registered trademark of Maytag orporation or its related companies and used under license to Goodman ompany, L.P. All rights reserved. Our continuing commitment to quality products may mean a change in specifications without notice. 08 Goodman ompany, L.P. Houston, Texas 0 www.amana-hac.com SS-