AFIREFENIX SZ1-K 0,6/1 kv PH120 (AS+)

Similar documents
IEC UNE DESIGN. 1. Conductor. 2. Insulation. Cross-linked polyethylene (XLPE) 3. Outer sheath. Flexible PVC, black colour.

600/1000V XLPE Insulated, LSZH Sheathed, Double steel tape Armoured Power Cables (3 Cores)

600/1000V SR Insulated Flexibles Control Cables (2-4 Cores & Multicores)

High Performance LSZH Fire Resistant Cable

PRODUCT CATALOGUE Norröna

Classification Report

600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (Multicore)

The Quality Connection. BETAflam Fire Resistant Safety Cables

DELTA Classification Report

OIL & GAS INDUSTRY OTHER INDUSTRIES

Üntel is ready for CPR

CPR: EUROCLASSIFICATION & TESTS FOR CABLES

New European Cable Testing and Classification

Construction Products Regulation (CPR) and BS 6701

fire resistant cables

FIRE RESISTANT CABLES

Belcom Cable excellence engineered through quality. CPR Construction Products Regulation

Flame Retardant Overall Screened Instrumentation Cables (multicore)

Traction Cable Radox 3 GKW

Caledonian Flame Retardant Coaxial Cables

FIRE RESISTANT CABLES FP400

Havells Fire Survival Cables

Double insulated, electron-beam cross-linked, halogen free photovoltaic wire sunlight resistant. Single conductor, flame retardant insulation.

Table of Contents. TELE-FONIKA KABLE SA (DMCC Branch). 4 TELE-FONIKA Kable Group 6 FLAME-X 950 SERIES 1 11 FLAME-X 950 SERIES 2

UK Direction BS7671 BS 8492 BS /01/2018

SPECIAL ELECTRICAL AND OPTICAL CABLES

FUMEGUARD TM QUALITY APPROVED CABLES. Cables Limited MADE IN IRELAND SINCE 1934 IDH CABLES LIMITED LOW SMOKE HALOGEN FREE CABLES

BS FP600 achieves the maximum 120 minute rating under the BS test conditions, which is required for fire fighting applications.

White paper. Construction Product Regulations* by Multimedia Connect. Which cables are concerned by these new regulations?

Catalogue Power Cables

STANDARDS INSTALLATION. Certificate No 077m

Caledonian Fire resistant Coaxial Cables

CONTENTS. Introduction Customer Service BS codes of practice BS Fire Performance Cable Selection Guide... 7

The Quality Connection. BETAflam safety cables for highest demands

IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission

Cable technology for highest safety requirements

OFFSHORE CABLES. Top Cable Central Headquarters. Leonardo Da Vinci, number Rubí (Barcelona) Spain

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Additional reaction to fire classification report No H

GUARDIANTM QUALITY APPROVED CABLES. Cables Limited MADE IN IRELAND SINCE 1934 IDH CABLES LIMITED MECHANICALLY PROTECTED CABLES

FIRE RESISTANT CABLES FP300

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red

WHAT MAKES PRYSMIAN CABLES DIFFERENT?

Total Fire Solutions. Includes BS 8519 and the updated BS :

INTRODUCTION. Our diverse range of world-class Specialty Insulated Wires and Cablesinclude: LV Cables -

Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design.

Fire alarm cables. for highest safety requirements TRADITION INNOVATION PASSION

CONSTRUCTION PRODUCTS REGULATION MOLEX CES COPPER AND FIBRE CABLE

Wires, Cables, Cords and Adhesive Tapes

Power Cables. Introduction 3 RV 4 RVMV 5 RVSV 6 RVFV 7. ELECWIRES 2 Page

All Prysmian FP400 cables are manufactured under an ISO 9001 Quality System certified by BASEC and LPCB.

Photovoltaic Cables EN H1Z2Z2-K

DNVGL-CP-0401 Edition February 2016

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red

BS /1000V XLPE Insulation LSZH Sheath Cables

Electrical test. Determining resistance of conductors by means of using DC four-wire connection measurement

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Data sheet OpDAT universal cable 1x24 OM4 - bend insensitive

PHOTOVOLTAIC CABLES. Photovoltaic Cable 2000V/1500V Photovoltaic Cable 2000V/1000V

SAS Security and Alarm Safety Cables

LSOH Flexible Cables

Reaction to fire classification report No C

THE TRUE FIRE SURVIVAL CABLE

FIRE PERFORMANCE CABLE

Construction Products Regulation (CPR)

ENHANCED FIRE PERFORMANCE CABLE

Reaction to fire classification report No C-rev.1

DNVGL-CP-0399 Edition March 2016

DNVGL-CP-0402 Edition February 2016

(Notices) EUROPEAN COMMISSION

Firetuf Cables ZERO HALOGEN, LOW SMOKE (0HLS ) CABLE

GUCN. Central Loose Tube Cables Universal Indoor / Outdoor - Corrugated Steel Tape Armor (CST) A/I-DQ(ZN)(SR)H Full Rodent Protection v13.

Firetuf Cables ZERO HALOGEN, LOW SMOKE (0HLS ) CABLE

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

Lloyd s Register Type Approval System Test Specification Number 3

CORRIGENDA. (Publication of titles and references of harmonised standards under Union harmonisation legislation)

Catalogue Telecommunication Cables INTRODUCCIÓN

Introduction.

Energy Division Heat-shrinkable joints for halogen-free, flame-retardant and fire-resistand cables up to 1 kv

GCRG. Multi Loose Tube Cables Universal Indoor / Outdoor A/I-DQ(ZN)BH Improved Rodent Protection v7.0. Ordering Information.

(Publication of titles and references of harmonised standards under Union harmonisation legislation) (Text with EEA relevance) (2017/C 298/02)

REACTION TO FIRE OF CABLE SYSTEMS. G. DENCHE* N. GENERÓ O. RODRIGUEZ Red Eléctrica de España S.A.U. Grupo General Cable Sistemas

AFUMEX LSX LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 PRODUCT DATASHEET & APPLICATIONS GUIDE KEY BENEFITS:

Data sheet OpDAT breakout cable 12x1 OM4 - bend insensitive, class Dca s1 d1 a1

BT Cables Technical Seminar CIBSE South Wales Region. Nov 17

LV FIRE RESISTANT CABLES

AFUMEX LSX BASEC APPROVED LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 PRODUCT DATASHEET & APPLICATIONS GUIDE KEY BENEFITS:

BS EN : Measurements Of Smoke Density Of Electric Cables. WF Report Number. Date: 17 th November Test Sponsor:

Fire Resistant Cables

Author Owner Issue Authority Name: Gordon MacKenzie Title: Senior Engineer Engineering Design and Standards

CMZH Low Smoke 0-Halogen Flame- Retardant Mass Transit Tag

Single core cables with reduced wall thickness

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

BS EN :2004. Test On Electric And Optical Fibre Cables Under Fire Conditions. WF Report Number. Date: 14 th November 2008.

System Circuit integrity in the event of fire. Safety cables and systems from a pro. Cabling Solutions

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

outdoor and indoor campus backbone, building backbone (riser) FDDI, Gigabit Ethernet and ATM Easy to install direct burial halogen-free

BS EN :2004. Test On Electric And Optical Fibre Cables Under Fire Conditions. WF Report Number. Date: 14 th November 2008.

Transcription:

Page 1 / 7 Construction and tests. Standards: UNE 211025 Compliance with the Low Voltage Directive (LVD): 2014/35 / EU Construction Products Regulation (CPR) - Regulation (EU) Nº 305/2011: Reaction to fire - Cca-s1b,d1,a1 Certified by AENOR (Nbr. 042/001093 - UNE 211025 Product range: From 1 to 5 cores. From 1,5 up to 300 2 ) PH120 Resistance to fire (EN 50200, EN 50362, IEC 60331-2, IEC 60331-1 120 minutes) RoHS compliant 1. TECHNICAL FEATURES 1.1. Technical designation 1.2. Rated Voltage Uo/U/Um =0,6 / 1 / 1,2 kv C.A 1,5 kv C.C. / Umax= 1,8 kv C.C 1.3. Maximum Conductor Temperatures Normal operation 90ºC Short circuit (5 seconds max.) 250ºC 1.4. Voltage test. Alternate current 3,5 kv (5 minutes) 1.5. Fire Performance. Standard - Resistance to fire: EN 50200, EN 50362, IEC 60331-1 & 2 (PH120 - At least 120 minutes, 842 ºC) (These cables keep the electrical supply and the integrity of the circuits & equipment although they are affected directly by the fire, at least 120 minutes at 830-870 ºC). - Reaction to fire: C ca -s1b,d1,a1 (EN 50575:2014+A1:2016) Flame retardant: EN 60332-1-2; IEC 60332-1 (H 425 ) Fire retardant: EN 50399 (flame source: 20,5 kw; Fs 2 m) Low heat generation: EN 50399 (flame source: 20,5 kw) Total heat released: THR 30 MJ Maximum value of the heat released: Peak HRR 60 kw Indication of heat increase: FIGRA 300 W/s Low production and opacity of emitted smokes (s1b): s1: Total smoke production (TSP) 50 m 2 & Peak value of smokes released (Peak SPR) 0,25 m 2 /s s1b: s1 + 60% < Transmittance < 80 % (UNE EN 61034-2; IEC 61034-2) Low production of flaming droplets (d1): d1: No flaming droplets/particles persisting longer than 10' occurs within 1200'. (EN 50399 - flame source:20,5 kw): Low acidity and conductivity of the emitted gases: a1: ph 4,3 conductivity < 2,5 µs/ (EN 60754-2; IEC 60754-2) DoP: MC1000SZ1K Range classified: 1x(1,5... 240 2 ) / 2x(1,5... 35 2 ) / 3x(1,5... 70 2 ) / 4x(1,5... 120 2 ) / 5G(1,5... 95 2 ) For more information, please check out "CPR/DoP" section in our website www.miguelez.com. *The packaging labels of these cables include the CE marking according to the CPR Regulation ((UE) Nº 305/2011) articles 8 and 9. Other performances: Fire retardant: UNE EN 60332-3-24 / IEC 60332-3-24 (cat. C) Halogen free. Low emission of toxic gases: UNE EN 50267-2-1 / IEC 60754-1 In case of fire, the emission of hydro-chlorate acid is lower to 0.5%. Fluor<0,1%

Page 2 / 7 2. CABLE DESCRIPTION. 2.1. Construction. Based on standard UNE 211025 Conductor. Flexible, annealed, plain copper conductor, class 5 according to IEC 60228; UNE EN 60228;. Special cross-linked, halogen free compound (silicone) acc. to EN 50363-1. Core. Assembly of conductors. In multicore cables, the cores are cabled helically. Filler Extruded filler for multicore cables. The materials are suitable for the operating temperature of the cable and compatible with the insulating and sheathing material. Oversheath Halogen free material based on a thermoplastic polyolefin type ST8 acc. to International standard IEC 60502-1 & Polyolefin Z1 according to the requirements of Spanish standard UNE 21123-4. Sheath colour: orange. 2.2. Design. Silicone Conductor Copper Class 5 Oversheath Polyolefin Z1, Halogen free type ST8 2.3. Marking. This cable is marked with the initials (AS+) = High Security reinforced cable AENOR MIGUELEZ SZ1-K 0,6/1kV PH120 (AS+) NXS YY 90ºC clase Cca-s1b,d1,a1 EN 50575 X,x mts Where: N = Number of cores X = X or G. X= without G/Y conductor; G=with G/Y conductor S = Cross sectional area in 2 YY = Last two digits of the year of manufacture X,x m = Meter marking *The packaging labels of these cables include the CE marking according to the CPR Regulation ((UE) Nº 305/2011) articles 8 and 9.

Page 3 / 7 3. APPLICATIONS. 3.1. Installation. Fixed installation 3.2. User Guide. cables are recoended for all those installations in which it is necessary to keep the integrity of the circuits and equipment although they are affected directly by the fire. Adequate for non-autonomous security circuits and service circuits with a centralised autonomous source (alarm circuits, signalling and emergency lighting systems, acoustic signalling, smoke extractors, water pumps for fire extinction). It is specially indicated their use in public concurrence places (airports, museums, malls and shopping centres, schools, hospitals, cinemas, hotels, sports stadiums...), and in general, whenever an important fire risk exists or it s required a low smoke emission and corrosive gazes in case of fire (i.e.: Railway and roadway tunnels, canalisations with bunched cables, vertical canalisations in buildings ). Cables are suitable for transport and distribution of electrical energy in fixed facilities. 3.3. Installation methods 1 Surface mounted (directly installed or on cable trays, cable ladders, cleats, brackets or in cable ducting (conduit,), pipes or similar closed systems)). In the case the cable is installed on cable brackets or cleats, the horizontal distance between cleats should not surpass 20 times the overall diameter of the cable. The distance is also valid between points of support in case of laying on cable racks or inside cable trays. The maximal distance between supports will never be greater than 80 cm under any circumstances. Embedded (in cable ducting). In building voids and cavities (directly or on cable trays, cable ladders, in cable ducting). Buried in ground (in conduit) In case of separate laying of single-core cables, cleats made of plastics or cleats consisting of non-magnetic metals must be used. Cables and bundles of cables are to be tightened in such a way that damages in form of indentation marks by pressure caused by heat expansion are avoided. Lowest temperature for cable laying and installation: Lowest temperature of cable during installation is 0ºC under normal conditions of care. This temperature is valid for the cable itself and not for the environment. If possible, the temperature of the cable shall be raised before laying, e.g. in a heated building, to facilitate handling and reduce the risk of damages. Minimum bending radius: D= Overall diameter of the cables () MINIMUM BENDING RADIUS D 50 5 D D > 50 6 D D= Overall diameter of the cables () Bending nearby the temperature limits should be carried out extra carefully. Maximum pulling force: The maximum pulling force must not exceed: F = 50 x S (N), where "S" is the cross-sectional area of the conductors ( 2 ) and 50 N/ 2 is the permissible tensile stress for cables with copper conductors (if the traction force is applied on the conductors) F = 5 x D 2 (N), where D = overall diameter of the cable (). (if the traction force is applied on the outer sheath) 1 It must be respected the methods of installation established by the standards and regulations that will affect each individual case. The user must be careful with the chosen installation method and accessories in order to assure the same safety warranties and fire performance than the cable.

Page 4 / 7 4. DIMENSIONAL CHARACTERISTICS 5. Cross sectional area thickness Overall Ø Weight Max. Electrical resistance at 20ºC D.C. ² kg/km Ω/km 1x1,5 0,8 6,2 54 13,3 1x2,5 0,8 6,4 67 7,98 1x4 1,0 7,4 93 4,95 1x6 1,0 8,0 110 3,3 1x10 1,0 9,0 160 1,91 1x16 1,0 9,9 218 1,21 1x25 1,2 11,7 314 0,78 1x35 1,2 12,9 416 0,554 1x50 1,4 14,7 575 0,386 1x70 1,4 16,5 780 0,272 1x95 1,6 19,0 1.010 0,206 1x120 1,6 20,3 1.240 0,161 1x150 1,8 23,0 1.560 0,129 1x185 2,0 24,9 1.872 0,106 1x240 2,2 28,0 2.465 0,0801 1x300 2,4 29,4 2.890 0,0641 Weight and overall diameter values are approximate and subject to normal manufacturing tolerances NOTE: In blue color, products with reaction to fire classification.

Page 5 / 7 Cross sectional area thickness Overall Ø Weight Max. Electrical resistance at 20ºC D.C. ² kg/km Ω/km 2x1,5 0,8 9 105 13,3 2x2,5 0,8 9,8 140 7,98 2x4 1 12 223 4,95 2x6 1 13,2 277 3,3 2x10 1 14,8 389 1,91 2x16 1 17 547 1,21 2x25 1,2 20,6 805 0,78 2x35 1,2 25 1.084 0,554 2x50 1,4 26,5 1.511 0,386 2x70 1,4 29,5 1.997 0,272 2x95 1,6 33,6 2.618 0,206 3G1,5 0,8 9,5 125 13,3 3G2,5 0,8 10,3 170 7,98 3G4 1 12,7 260 4,95 3G6 1 14 350 3,3 3G10 1 15,7 500 1,91 3x16 1 18,1 670 1,21 3x25 1,2 21,9 1.172 0,78 3x35 1,2 26,4 1.577 0,554 3x50 1,4 30,3 2.215 0,386 3x70 1,4 34 2.955 0,272 3x95 1,6 35,9 3.860 0,206 Weight and overall diameter values are approximate and subject to normal manufacturing tolerances NOTE: In blue color, products with reaction to fire classification.

Page 6 / 7 Cross sectional area thickness Overall Ø Weight Max. Electrical resistance at 20ºC D.C. ² kg/km Ω/km 4G1,5 0,8 10,3 160 13,3 4G2,5 0,8 11,3 210 7,98 4G4 1 13,8 310 4,95 4G6 1 15,3 415 3,3 4G10 1 17,2 692 1,91 4x16 1 19,9 1.100 1,21 4x25 1,2 24,1 1.260 0,78 4x35 1,2 29,1 1.960 0,554 4x50 1,4 33,4 2.600 0,386 4x70 1,4 38,1 3.505 0,272 4x95 1,6 43,5 4.558 0,206 4x120 1,6 49 5.740 0,161 4x150 1,8 50,1 7.771 0,129 4x185 2 52,6 8.602 0,106 4x240 2,2 59,2 11.165 0,0801 5G1,5 0,8 11,2 190 13,3 5G2,5 0,8 12,5 245 7,98 5G4 1 15,2 380 4,95 5G6 1 16,7 500 3,3 5G10 1 19 720 1,91 5G16 1 21,9 1.070 1,21 5G25 1,2 26,6 1.580 0,78 5G35 1,2 32 2.360 0,554 5G50 1,4 37,1 3.260 0,386 5G70 1,4 42 4.250 0,272 5G95 1,6 48 5.400 0,206 Weight and overall diameter values are approximate and subject to normal manufacturing tolerances NOTE: In blue color, products with reaction to fire classification.

Page 7 / 7 5. COLORS (Core Identification) The identification of the conductors is according to the standard HD 308 S2. 2x - brown and blue 3x - brown, black and gray 3G - brown, blue and yellow / green 4x - brown, black, gray, blue 4G - brown, black, gray, yellow / green 5G - brown, black, gray, blue, yellow / green