Micro and Mini Torch. Zones: 0, 1, 2, 20, 21 and 22. Product Overview. Features & Benefits. Certifications

Similar documents
ATEX. Wolf Safety Lamp Company. The widest range of portable ATEX lighting approved for use in explosive atmospheres

distributed by Sole Agent in Great China Universky (Jiangsu) Technologies, Inc. Phone: Fax:

ATEX. Wolf Safety Lamp Company. Includes NEW LinkEx LED. The widest range of portable ATEX lighting approved for use in explosive atmospheres

Wolf Safety Lamp Company HAZARDOUSAREA PORTABLE & TEMPORARY LIGHTING POWER DISTRIBUTION

INTRINSICALLY SAFE LIGHTING RANGE

Trusted worldwide since 1989 INTRINSICALLY SAFE RANGE

INERIS 01ATEX0060 (standard) TR CU (marking upon request, ordering code to be required)

NexLED. Ex e LED BULKHEAD. Features. Standard Specification. International Approvals. NexLED with Exit Sign kit

ARRAN LED LED FLOODLIGHT. Standard Specification. Features

60W Flameproof LED Emergency Linear Fixture V AC - (2) 30W LED Lamps - ATEX/IECEx

GRP Flameproof Combination Signal db(a) / 5 Joule Series YL6S

Multiple Status Indicators Series MEXE, MS25, MS35, MS45, MS55

EVL-B - Zone 1, 2, 21, 22 - Replaces traditional discharge lamps more than 400W - Saves in energy, maintenance and installation

Hazardous Areas - EXPLOSIONPROOF SOLENOIDS

Low Profile Clean Room 150W LED Light - 2x2 Lay-In Troffer C1D1 - C2D2 - ISO 14644/FS-209E

High Quality LED Lighting!

Guide for hazardous areas

Weighing Solutions for Hazardous Areas FULL COMPLIANCE WITH ATEX DIRECTIVE

FLASHLIGHT ANSI STANDARDS

Integrated Solutions Low Voltage Systems

HDL106 LED LUMINAIRES. For Harsh & Hazardous Environments.

High bay LED lighting fixture

Illumination unit For sight glass level indicator Model LGI

Light with a System. PARAT LIGHTING PARAT LIGHTING CONTENT QUICK PRODUCT FINDER PARALUX PARASNAP PARAT X-TREME. Safe lighting for professional users:

INSTRUCTION MANUAL (ATEX / IECEx)

PRODUCT OVERVIEW. Light fittings, boxes & custom built control panels for explosive atmospheres

40W Explosion Proof LED Light Fixture - C1D1, C2D1-2x2 Lay-in Troffer - ATEX/ISO Rated

Gas leak detectors. For a quick overview. testo testo testo testo gas detector testo 316-Ex

OPTIBAR P 1010/2010 C Supplementary instructions

CCA-03EX. - Easy installation - Low energy consumption - New COB LED technology - Zone 1, 2, 21, 22. Directional LED spotlights

ATEX, NOMENCLATURE AND CODING

Dräger X-am 2500 Multi-Gas Detection

Inspection Light LED 6149/2. Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN

Gas cylinder scale Model GCS-1

UL HAZARDOUS LOCATIONS SERVICES

Intrinsically Safe Solutions

25W Explosion Proof Surface Mount LED Light - C1D1-2 - C2D1-2 - Aluminum Frame V AC

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

We measure it. testo 316-Ex CH 4 testo 316-1

Gas leak detectors. For a quick overview. testo testo testo testo gas detector testo 316-Ex.

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

ATEX Explained A brief Introduction

Airo Wireless Intrinsically Safe White Paper. Written By: David Schmitt

Technical Data. General specifications. Rated operating distance s n 5 mm

Specification Sheet. Certificates. Features. Application. Anti-Explosive Lamp

ATEX, NOMENCLATURE AND CODING

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

Dräger X-am 7000 Multi-Gas Detection

INSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations

Officine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0

Certification Supplement Manual

Distributed by ECO LIGHT PRODUCT OVERVIEW. Hazardous Area Luminaires

DB4 Range - SPEAKERS - Up to 25 Watts

DTS Light fittings for explosive atmospheres

FLASHLIGHT ANSI STANDARDS

PERSONAL COMBUSTIBLE GAS DETECTOR

of Conformity IECEx Gert f cate Test Safe

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 236

EJBX. Ex d. AISI 316L stainless steel. - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67

Dräger Polytron 5700 IR Detection of flammable gases and vapours

ATM Lighting sp. z o.o

ATEX. Tough controls for tough environments. ia.danfoss.com. Brochure Controls. Danfoss controls - designed and approved for hazardous areas

Dräger X-am Dräger X-am 3000: Designed for the harshest industrial environments.

ATM Lighting sp. z o.o

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

5 yr. Vitalite Rotating Warning Light. Models 121 and 121A LIGHT DUTY VEHICULAR LIGHT

Guide to Hazardous Location Approvals:

CO warning instruments and gas spillage detectors

Guide to Hazardous Location Approvals: MICRO SWITCH Hazardous Area Limit Switches

Celebrating YEARS Manufacturers of Visual & Audible Signalling Devices. NEW Exd

INSTRUCTION MANUAL. D2xB1XH1 & D2xB1XH2 Xenon Beacons For use in Hazardous Locations

INSTRUCTION MANUAL (ATEX / IECEx)

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

Erik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories

VERSAFLOW VORTEX Supplementary instructions

Safety instructions VEGADIF DF65.GX*****H/Z/P/F***** IECEx BVS

OPTIBAR DP 7060 Supplementary Instructions

300W Low Profile Clean Room LED Light - LED Signal Light - C1D1 - C2D2 - ISO 14644/FS-209E Rated

208W Explosion Proof Low Profile LED - Emergency Backup - 27,040 Lumens - C1&2 D1&2 - ATEX /IEC

Products for the area

4) Intrinsic Safety Certification

D O M E S T I C LED. Lighting C O M M E R C I A L

CHALLENGER 66 INDUSTRIAL

Report No EC. 1 Windsor Dials, Windsor, Berkshire, UK. SL4 1RS ATEX CERTIFICATION REPORT. Electronstandart-pribor

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Dräger X-am 2500 Multi-Gas Detector

Explosion Proof Light - Base Stand Mount - 16 Inch Watt LED - Class I Div 1 C&D

33 Watt Low Voltage LED Fixture for Hazardous Location Lighting - Low Profile Linear Fixture - C1D2

LED NEW FB-SERIES LED NEW-SF FIXTURE LED NEW-SD FLOODLIGHT LED NEW-SD STREET. LED Explosion-proof Platform Light. LED Tri-proof Light

300W EXP LED Light - 35,000 Lm - 3' Cart Mount - Quick Change Mount - C1D1-100' 16/3 SOOW- EXP Plug

Dräger X-am 5000 Multi-Gas Detection

500 Watt High Mast (Stadium) LED Light - 60,000 Lumens Outdoor Rated

PRODUCT DATA SHEET ilh8

Certification Supplement Manual

standards: standards:

IR1xxx Series 1, IR2xxx Series 1 Miniature Infrared Gas Sensors for Hazardous Areas and Intrinsic Safety in Mining

PROTÉGÉ ZM SINGLE GAS MONITOR

EN54-5, ATEX and IECEx approved Highly durable Automatic reset after cooling Range of alarm temperatures

XLFE-4/1. Borosilicate glass globe

Compact, robust crimping tool. suitable for a variety of noninsulated. terminals. Also features a cable cutter and spring return.

Transcription:

Micro and Mini Zones: 0, 1, 2, 20, 21 and 22 Product Overview Features & Benefits The Micro and Mini es use high-tech light sources to give impressive performance with a compact size, designed for easy pocket storage, and are CE marked to the ATEX Directive and IECEx certified for safe use in potentially explosive gas, vapour, mist or dust atmospheres, where a T4 or T5 temperature class permits. All models are approved to Group I for use in mining applications. The LED models; M-10 Micro, M-40 and M-60 Minis are approved as Category 1 equipment for use in Gas Zones 0, 1 and 2, and Dust Zones 20, 21, 21 and the M-20 Xenon Mini is approved as Category 2 equipment for use in Gas Zones 1 and 2. The M-10 Micro has a single white 5mm Nichia LED light source and is powered by four alkaline LR44 button cells, giving an impressive beam with a two hour duration from a very compact size. The M-20 Mini uses a Xenon filament bulb powered by two LR03 AAA cells, giving an excellent narrow beam of light with good range and up to 2.3 hours duration. The M-40 Mini has a cluster of three white 5mm Nichia LEDs, and the M-60 Mini uses a single high power Cree LED giving remarkable light output; both products are powered by three alkaline LR1 N cells giving up to ten hours of usable light with the M-40 and up to 3.5 hours* of usable light with the M-60. All supplied with cells. ATEX and IECEx Certified T4/T5 temperature class Ultra small size Lightweight, ergonomic design Proven impact resistance Single handed switching Switch protection shroud Integral pen style pocket clip IP67 water and dust tight Gas and Dust Approval (M-20 Not Dust approved) Group I Mining Approval Certifications The Micro and Mini es have an ergonomic design and are constructed from high quality thermoplastic resin, with excellent impact and chemical resistance and the polycarbonate lens is set-back within the lens ring to minimise risk of damage. All models have a lanyard hole (M- 10 Micro supplied with neck cord), an integral pocket clip for secure retention and to prevent roll on a flat surface, and a push-button for single-handed switching, which is shrouded to guard against accidental operation. All models are certified IP67, sealed against water/dust ingress. NSN codes 6230-99-1823546 - M-60MOD

Technical Specification Product Reference M-10 M-20 M-40 M-60 Product Description LED Micro Xenon Mini LED Mini 1W LED Mini Code Industrial Gas I M1/II 1GD Ex ia I Ma/IIC T5 Ga I M2/II 2G Ex ib I Mb/IIC T4 Gb I M1/II 1GD Ex ia op is I Ma/IIC T4 Ga I M1/II 1GD Ex ia op is I Ma/IIC T4 Ga +40 C) Dust Ex ia IIIB T95 C Da IP67 N/A Ex ia op is IIIB T125 C Da IP67 Ex ia op is IIIB T130 C Da IP67 Mining I M1 Ex ia I Ma IP67 I M2 Ex ib I Mb IP67 I M1 Ex ia I Ma IP67 I M1 Ex ia op is I Ma IP67 Type of Protection ia ib ia Area of Class (Gas) Zones 0, 1 & 2, Zones 1 & 2, Zones 0, 1 & 2, Gas Group IIC Gas Group IIC Gas Group IIC Temp. Class (Gas) T5 T4 Ambient Temp. -40 C to + 50 C -40 C to + 40 C -40 C to + 50 C Area of Class (Dust) Zone 20, 21 & 22, Dust Group IIIB Zone 20, 21 & 22, Dust Group IIIB Max Surface Temp. (Dust) 95 C 125 C 130 C Certification Baseefa06ATEX0084X - IECEx BAS 06.0023X Enclosure Impact Resistant Thermoplastic Lens Polycarbonate Beam Type Medium Spot Narrow Spot Medium Spot

Light Source Part No. - M-201 - - Type 1x5mm LED White (Nichia) Xenon Filled Filament Bulb 3 x 5mm LED White (Nichia) 1 x High Power Cree LED Rating - 2.3V 0.3A - 1 Watt Output 30 cd 15 lm 3 x 30 cd Up to 107 lm Life 25,000 hrs 30 hrs 25,000 hrs Power Source Part No. M-102 (4 pack) M-202 (2 pack) M-402 (3 pack) Type LR44 Primary Cells to IEC60086 LR03 Primary Cells to IEC60086 LR1 Primary Cells to IEC60086 Volts 4 x 1.5V 2 x 1.5V 3 x 1.5V Light Duration Up to 2 hrs Up to 2.3 hrs Up to 10 hrs 1.5-3.5 hrs* Ingress Protection IP67 to EN60529:1992 Weight (incl. cells) 25g 60g *M-60 battery duration/light output is dependent on battery make and type. All information has been gathered under laboratory conditions, the user must regard the values given as approximate. Changes may be made to the above specification without notification, details are available on request. Product Dimensions Light Output M-10 Spot Beam (approx. 13 ) Peak luminous intensity at 2.5m 8 lux M-20 Spot Beam (approx. 6 ) Peak luminous intensity at 2.5m 100 lux M-40 Spot Beam (approx. 18 ) Peak luminous intensity at 2.5m 15 lux M-60* Spot Beam (approx. 8 ) Peak luminous intensity at 2.5m 275 lux

Version: SL011 Issue 11 DF498 Wolf Safety Lamp Company, Saxon Road Works, Sheffield, S8 0YA, UK T: +44 (0) 114 255 1051 F: +44 (0) 114 255 7988 E: info@wolfsafety.com www.wolfsafety.com