EXICALL EN70 EXICALL EN70MR EXICALL EN70-ATEX

Similar documents
EasyAlarm ELEVATOR LEITRONIC AG

EA-MINI / EA-MINI-V. LEITRONIC AG Swiss Security Systems

EXICALL EN70MR EXICALL EN70-ATEX (upright version EXICALL EN70MR) (horizontal version EXICALL EN70MR)

LEITRONIC AG Swiss Security Systems EasyAlarm ELEVATOR

User instructions EasyAlarm CONTROL

ANEP S-BOX EMERGENCY TELEPHONE FOR ELEVATORS.

Memcom Emergency Telephone

HELPY QUICK-TL GSM INTL

Memcom + Emergency Telephone

ANEP BOX - TA EMERGENCY TELEPHONE AND INTERCOM SYSTEM FOR LIFTS EMERGENCY TELEPHONE FOR LIFTS.

IC60 Sintony 60 Intrusion Control Panel

HELPY CONTROLLER QUICK GUIDE

PERMACONN PM1030 Includes DI300. Installation Manual

AUTODIALER SYSTEM FOR LIFTS MANUAL HELPY 2W-V

The Windcrest Remote Alarm for Passenger and Goods Lifts with Optional BS EN81-28 & BS EN81-70

Solution F2. Fire Alarm Control Panels one step ahead.

Basic Installation Manual

The EN54 Part 2 & 4 Fire System

16 Zone Voice Evacuation VA & PA Sound System

ADE Gen4. Speech Dialler Engineering Information. Description. Features

DIVA8MG2. Compact PAVA System Master Unit. DIVA8 System

Any additional devices linked to the system ET08 (computer, sensors, relays etc.) must be approved by LST EN standard.

Lifeline Vi Clever, not complicated

BENTEL SECURITY reserves the right to modify the technical features of this product without prior notice.

Octalarm-T: the latest in future-proof industrial alarm diallers

AT60 AUTO DIALLER User Guide

University. NewVoice. San Francisco Paris Geneva Zurich Linz Mainz Shanghai Brisbane Hong Kong São Paulo Dubai

Specialists in communications for the elevator industry

Security Alarm Systems

Health Care. NewVoice. San Francisco Paris Geneva Zurich Linz Mainz Shanghai Brisbane Hong Kong São Paulo Dubai

The complete wirefree security alarm solution

DESCRIPTION INSTALLATION

DigiPlus INSTRUCTION MANUAL

Call stations and extensions

AVCOM System Installation Instructions

SI120 Guarto Easy I. Alarm system. Fire & Security Products

DL150 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

SeCom. Combining communication and security in retirement- and nursing homes

SMS GSM Alarm Messenger

Instructions manual. By-alarm. By-alarm Manager software

IRIS Touch Firmware Enhancements and Additions from Version to Version

AIS-Module 400. Installation Manual. AIS-Module for: AS 40P, AS 4000, AS 100 IT

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

DSE ELECTRONIC SIRENS Advantages & Functions

Upgrade of PSTN network Alarm System

Voice Board. Installation and Programming Guide. Runner 4/8,PowerWave 4/8/16 &, Elite64. Add-on Board For Storing Recorded Voice Messages

Preface. Thank you for purchasing our GSM Security Alarm System ( The System )! The System will keep your home and property safe around the clock.

Elemec3. Networked Public Address and General Alarm System (PA/GA)

All tested. Easy Series Intrusion Control Panel Making security easy featuring wlsn* * wireless Local SecurityNetwork

4.2. Characteristics. handset

MG Partition 64-Zone Wireless Console with GPRS/GSM Version 1.6. Section Programming Guide

AD1000EN-1R configured to operate as a DG1000

ProCom The App for Alarm Systems in the Protect Series Operating Manual

EN ASTRO-PA/GA System. ASTRO-PAGA Digital IP Public Address & General Alarm SYSTEM for INDUSTRIAL SAFETY APPLICATIONS

ATSTORM v2. The sensor with FCES technology is connected to the interface with a communication cable.

NON-MONITORED EMERGENCY CALL SYSTEMS

AlertWave. visiplex. From a Public Address System to an Emergency Communication System... The AlertWave system advantages:

OPEN THE DOOR TO INNOVATION. 2N ELEVATOR SYSTEMS - Emergency communication devices for any lift.

All-In-One Wireless Security System V3.2 Programming Guide. Model # MG6130 / MG6160

SAFETY AT SCHOOLS. We supply sound, not equipment. the integration of intercom and voice alarm systems makes schools safe.

USER & INSTALLATION GUIDE

TYDOM 315. * _Rev.2* GSM domotics transmitter. 1. Presentation

English. Doro CareIP Mobile. User Guide

SeCom Combining communication and security in retirement- and nursing homes

ELECTRICAL COMPONENTS REMOTE LIFT ALARM

IRIS Touch 400 & 600 Range Installation Manual. Honeywell Galaxy Range. Version 2.0

telecommunication systems

Public Services. NewVoice. San Francisco Paris Geneva Zurich Linz Mainz Shanghai Brisbane Hong Kong São Paulo Dubai

IEC Electroacoustic EMERGENCY WARNING SYSTEM. for a maximum of system security 79

SOLUTIONS FOR SENIOR CARE FACILITIES BUSINESS COMMUNICATION SERVERS

GLOBAL. InstallatIon & operation manual

SP40S-D. Kingfisher Company, inc. Features: Description:

Architectural and Engineering Specification for a. Flash / Flare

TELECOMMUNICATION. Telecommunication. Wireless Phone

IRIS Touch 200 Range Dialler Installation Manual. Version 1.4

GAI-Tronics Systems NEW! Elemec3 Digitally Controlled PA and General Alarm system PA/GA

Safety is individual! Flexible alarm dialler bébétel / EasyAlarm LEITRONIC AG. Baby monitorin Home security Personal security Technical alarm

DualCom GradeShift UDL QUICK GUIDE & INSTRUCTION MANUAL

Remote switching machines with a SMS text from your mobile phone! Remote Monitoring your assets in the worldwide by your mobile Phone!

FIRElux Emergency Lighting

Firefighter Lifts 81-72

Products compliant with the following standards and regulations: EN81/70, EN 81/28 and EN 81/72. Lead-free manufacturing. Reduced energy consumption

DIY kit alarm system. Model LYD 118 New Launch Touch Screen GSM Alarm System

Sentient. Downloader Manual D4854

QUICKFIT INSTALL HOOK-UP SHEET FOR ESL KIT REV 1.17 OP

600 Range Dialer Installation Manual. Version 1.0

Application Notes for Configuring NovaLink NovaAlert SIP with Avaya IP Office Issue 1.0

OPERATOR S MANUAL MODEL AP15/AP15-1/AP15-2 PC-ALARM PANEL

N-8000 SERIES IP INTERCOM SYSTEM

"VOICE OF SECURITY: Trends In Intercom, Public Address, and Mass Notification Emergency Communications

Security designed for your lifestyle

Warranty: 12. The dialer shall be covered by a two (2) year warranty covering parts and labor performed at the Factory.

1. User features of the GSM dialer

SAFEPATH Mass Notification System (SPMNS)

Control Panel. 1.0 GENERAL SCOPE OF WORK Introduction... 2

Esmi Sense FDP Fire detection panel with ALC2 loop controller

Voice Module Installation Guide. For use with ProSYS 16, ProSYS 40, ProSYS 128

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

The Ultimate, Digital Public Address & Voice Alarm System FLEXIBILITY UNLIMITED

1. Introduction. 2. Product overview

Transcription:

LEITRONIC AG Swiss Security Systems ELEVATOR EMERGENCY DIALLER EXICALL EN70 EXICALL EN70MR EXICALL EN70-ATEX Issue: 18 August 011

1. Door phone (EXICALL EN70) EN81-70 emergency button Center> 90cm (<110 cm) from the cabin floor! Portrait: 1. Button from bottom Landscape: 1. Button from left Incoming line (PSTN) or GSM interface Optional: 30V AC Supply 10.. 35 V DC 8.. 0 V AC System-Interface (K1) Separated alarm contact K1 (K) Output to activate Video/Light (K3) Output door-opener 3 Telephone line Control wires/ Supply wires

. Elevator call (EXICALL EN70) Machine room Incoming line (PSTN) or GSM interface Cabin Emergency LED-light on cabin top or inside panel frame EN81-70 emergency button Center> 90cm (<110 cm) from the cabin floor! Portrait: 1. Button from bottom Landscape: 1. Button from left External button Misuse protection Supply 10..35V DC or 8..0 V AC! Optional sub-unit: EA-LMK Pit System-contact Connection to external alarm server (filtered alarm) Connection to Help is coming lamp Telephone line Control wires/ Supply wires

3. Elevator with machine room intercom (EXICALL EN70MR) MR-phone Incoming line (PSTN) or GSM interface Modem Machine room Cabin Emergency LED-light on cabin top or inside panel frame EN81-70 emergency button Center> 90cm (<110 cm) from the cabin floor! Portrait: 1. Button from bottom Landscape: 1. Button from left External button Misuse protection Supply 10..35V DC or 8..0 V AC! Optional sub-unit: EA-LMK Pit System-contact Connection to external alarm server (filtered alarm) Connection to Help is coming lamp Telephone line Control wires/ Supply wires Communication to machine room phone

4. Elevator with Fire Brigade - SET (EXICALL EN70MR+FWS-Set) Modem Machine room Incoming line (PSTN) or GSM interface Cabin Emergency LED-light on cabin top or inside panel frame Pit EN81-70 emergency button Center > 90cm (<110 cm) from the cabin floor! Portrait: 1. Button from bottom Landscape: 1. Button from left External button Misuse protection Supply voltage 10..35V DC With back-up! Optional sub-unit: EA-LMK System-contact Connection to external alarm server (filtered alarm) Connection to Help is coming lamp Fire-brigade mode: Supply: 8-35V DC Fire brigade entry Telephone line Control wires/ Supply wires Communication to remote-units

5. ATEX-Elevator / Fire brigade solution optionally Cabin Main-unit Emergency button Sub-unit on top in the cabin below cabin of the cabin EXICALL EN70-ATEX NT-ATEX LMK-ATEX 1 4+Shielding L 3m Terminal 4 4 3 I/O Tel 1 Fire brigade entry point Remote-unit LMK7B-ATEX Activate fire brigade mode: Power both remote-units Activate machine-room mode: Power remote-unit in machine room only 1 The mode switch has to conform to ATEX Machine room Outside ATEX area Remote-unit LMK7B-ATEX Supply 10 7 VDC 4 PSTN 1 X_LINE X_EARTH ATEX-AB 11.038 X_MR X_AMT 1

6. Module Description EXICALL EN70 This is the alarm unit located on top of the cabin in a protected area. The alarm unit includes full hands free communication using the integrated loudspeaker and microphone. EXICALL EN70 is available in to version (upright or horizontal) EXICALL EN70MR This unit includes an additional telephone interface to establish hands free communication with the machine room phone simply by lifting the handset see Machine room solution/ Fire brigade-solution under system prosperities. EXICALL EN70MR is available in to version (upright or horizontal) EA-LMK Sub-Unit EA-LMK is equipped with speaker and microphone to provide full hands free communication inside the cabin. It has a pluggable screw terminal to connect the emergency button. EA-LMK70B (EN 81-70) Sub-Unit EA-LMK70B is similar to EA-LMK but includes additional terminal: a) to supply alarm unit by 8..35 V DC from the control system or from the emergency light b) to connect the yellow and green indicator according to EN 81-70 c) integrated amplifier Machine room telephone Used in combination with Exicall EN70MR or EN70-ATEX. wire intercom to the cabin Fire brigade solution according to EN81-7 1 Set placed in machine room (MR) (integrated into IP- Box): Remote-unit EA-LMK7B-WG 1 Set placed in fire brigade entrance (FBR): Remote-unit EA-LMK7B-WG GSM interface (alarm transmission over GSM network) Supply voltage: 30 VAC / 50 Hz, 1 V / 1. Ah battery Connectors: Tel, Output : Operation, Output: Emergency light EXICALL EN70MR-ATEX ATEX-Version of EXICALL EN70MR LMK-ATEX ATEX-Version of sub-unit EA-LMK LMK7B-ATEX ATEX-Version of remote-unit EA-LMK7B-WG For machine room or fire-brigade solution

7. System Properties Highly Integrated Open System The elevator customer is free to choose the alarm centre because the alarm unit can be used as hands free dialler with clear voice instructions to any called party or alarm centre or as an alarm dialler with protocol exchange with a machine or PC. Share Telephone Line (Cost Reduction) Up to eight alarm units can share a single telephone line without additional equipment. During dialling in you can select the desired alarm unit simply by entering the corresponding pin code. Alarm Prioritization (Option PLUS) It is possible to share the telephone line (PSTN) between EXICALL EN70 and a telephone, fax or modem due to the automatically alarm prioritization. Therefore the costs of a second line can be saved. The alarm prioritization interface is included inside the alarm unit so no external components are necessary. Large Range of Accessories A large range of extension units (Microphone / Speaker) provide full hands free communication on a second location i.e. inside the cabin. The fire brigade interface allows three-point communication. Optional radio interface allows integrating radio sensors to adapt to individual applications. Reliable Platform The EXICALL platform is already in use in more than 1 000 locations. Self test Functions Various self test functions such as line test, battery test and periodic test call (= routine call according to EN81-8) make a high reliable system and serve determining the sources of problem during the installation process. Voice Guided User Interface The voice guidance permits a simple use of the system. In case of emergency the alarm unit announces the cause of the alarm followed by the individually up-spoken announcement (e.g. the location) so that the alarm centre is immediately informed where the call comes from. PIN-Code The pin code prevents from of unauthorized access (local programming or dial-in). It also can be used to identify the alarm unit during telephone connection in clear voice (using DTMF #) or as DTMF sequence (using DTMF A). Remote Access (Dial-in) The alarm or service centre can call back the alarm units either directly or with a two-step dialling in procedure. After identification by pin code it is possible or to establish a hands free communication with the cabin or to program the alarm number or change the individual announcement. Ways to Identify Alarm Units The identification ensured by the individually up-spoken announcement text, by the pin code announcement in clear voice (elevator number/asset number) or as DTMF sequence or using standard alarm protocol (Call centre / ADEMCO Point-ID).

Individual Configurations The varieties at attitude and configuration options permit to adapt the system to your needs, i.e. adjust activation time for emergency button, hands free volume, connection timeout and many more. Busy tone Detection The integrated busy tone detection allows to forward the alarm call to a next programmed telephone number avoiding unnecessary delay. Thus no valuable time is lost in the case of emergency. Misuse Protection The misuse protection circuit prevents from false alarm i.e. if the cabin door opens within the adjusted timeout. Installation test A special test mode facilitates the installation and debugging process of the wiring. All input signals are announced thereby: "Sensor 1//3 activated or deactivated". Intelligent Machine Room Communication Lifting the handset of the machine room telephone connects automatically with the cabin. If you press key 0 at the machine room telephone you get an external line (same function as in a hotel exchange). If the EasyAlarm needs the telephone line in order to set off an emergency call, the machine room telephone will be disconnected. Additionally the engine room telephone rings with an arriving call. Fire brigade communication (EN81-7) o Key switch activates fire brigade mode. o Standby: Microphone in the cabin is active (Speak); Machine room and fire brigade location are in listening mode. o If Speak -Button is pressed the microphone of this location is active (Speak) and the other locations are in listening mode ISDN, DECT, GSM The connection to an ISDN telephone system is possible, if an analogue interface is available (i.e. for fax). The telephone connection can be provided also via a GSM or DECT terminal. Alarm Centre Management The alarm unit supports the standard alarm protocol ADEMCO POINT-ID. Thus the alerting can be made to any alarm centre. The management program WinMOS can handle the 7-hour routine calls on a standard PC avoiding heavy installation and costs ( section 7). Standards EXICALL EN70 is conforming to European regulation EN81-70:003 and EN81-8.

8. Call Centre Solution Hardware The management software runs on a standard PC with ISDN interface. No expensive auxiliary equipment is needed! Management Software The management program WinMOS is based on the Windows platform. With WinMOS you: 1. can handle and log emergency calls (automatic identification of the location). can automatically dial back into the cabin 3. can administrate test calls (every 7h according to EN81-8) 4. get online help during possible interactions 5. Remote configuration for Leitronic units: EasyAlarm, Exicall ENxx Dialling numbers PIN-Code Dialling-in Periodical test interval 5