PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

Similar documents
PRODUCT DATA COMFORT 600 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 800 m 3 /h

PRODUCT DATA COMBI 300 POLAR BY NILAN. Ventilation with passive & active heat recovery. Active heat recovery. Passive heat recovery.

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

PRODUCT DATA COMFORT 300 TOP BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 325 m 3 /h

PRODUCT DATA COMFORT 1200 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 1400 m 3 /h

PRODUCT DATA COMFORT 5000 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 5300 m 3 /h

PRODUCT DATA VPL 15 TOP M2 BY NILAN. Ventilation & active heat recovery. Active heat recovery. Comfort heating. Comfort cooling.

PRODUCT DATA VPL 28 BY NILAN. Ventilation & active heat recovery. Active heat recovery. Comfort heating. Comfort cooling.

PRODUCT DATA COMPACT S BY NILAN. Sanitary hot water production. Passive heat recovery. Comfort heating. Ventilation < 375 m 3 /h. Active heat recovery

PRODUCT DATA COMFORT 302 TOP BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 345 m 3 /h

PRODUCT DATA VP 18 BY NILAN. Sanitary hot water production. Heating. Active heat recovery. Comfort heating. Ventilation < 300 m 3 /h.

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

VENTILATION = WELL-BEING

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

Comfortable indoor climate regardless of the season

Technical specifications

eco PREMIUM ENERGY RECOVERY UNIT» Technical instruction

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

Air Handling Unit. REC Temovex Blue 4 NEW! Experts on indoor climate in low-energy houses

PRODUCT DATA COMPACT P RANGE BY NILAN. Heating. Sanitary hot water production. Ventilation < 300 m 3 /h. Passive heat recovery.

VEX100 series Air handling units with cross-flow heat exchanger

Installation Instruction

TECHNICAL INFORMATION HCV 4 - HCV 5 - HCH 5 - HCH 8 Demand-controlled home ventilation

Air handling unit. REC Temovex 400S-EC-RS. Experts on indoor climate in low-energy houses

Swegon CASA W130. Ventilation unit with counter-flow plate heat exchanger HOME VENTILATION

TSEK VHR EC HEAT RECOVERY UNITS

USER MANUAL CTS700 TOUCH BY NILAN. Compact P / Compact P Polar (English)

MAXI CENTRALIZED VENTILATION WITH HEAT RECOVERY

AIR HANDLING UNITS RIS P EKO 3.0. New range - 5 sizes, 20 models! Efficient EC. E f f i c i e n c y up to 94%! E x t r e m e l y low height! fans!

Technical Information HXV - HRV Ventilation

TopMaster Air Handling unit. Technical data

39HX. High-efficiency dual-flow air handling unit PRODUCT SELECTION DATA. Plug & play unit (built-in control) Class A+ across entire range

The new Xcell EC High Efficiency Range Fresh air pure and simple

CONTENT: VEX308 Decentralised ventilation VEX308

VERSO Air Handling Units

GLOBAL LP. Ceiling-mounted ventilation unit with plate heat exchanger

panel filters with filtering class G4. Supply filter F7 can be supplied with the few models.

panel filters with filtering class G4. Supply filter F7 can be supplied with the few models.

Series VUT PW EC. wool internal heat and sound-insulating layer for VUT PE/PW 350, 600, 1000 units and 50 mm for VUT PE/PW 200, 3000 units.

Zehnder ComfoAir 550. Ventilation unit

Technical Information HCV - HCH Demand-controlled home ventilation

User manual. CTS 602 by Nilan VPL 15 VPL 15 TOP. Version: 9.02, Software-version: 2.21

VERSO Air Handling Units

Adsolair 56/58. Comfort air conditioning unit with double plate heat exchanger and adiabatic evaporative cooling system

CLIMASTER ZCF AIR HANDLING UNITS

Energy-efficient heat source provides comfort in large rooms

Swegon CASA R120. Ventilation unit with rotary heat exchanger HOME VENTILATION

User's Guide. CTS6000 control panel

Operation and maintenance instructions

KOMFORT EC DB Suspended heat recovery air handling units

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

Eco Active H E A T R E C O V E R Y S Y S T E M S. Heat Recovery Penthouse Turret. W: T:

User manual. User manual. CTS 600 by Nilan. Comfort Comfort Version: 10.00, Software-version: 2.30

Heat and energy recovery ventilators

KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S. Heat and Energy Recovery Ventilators

Homepage > Products > Decentralised ventilation systems > Vertical units > Type FSL-V-ZAB/SEK FSL-V-ZAB/SEK

FLOWAY. Floway Range. The dual-flow air handling unit with heat recovery guaranteeing an Economical and Durable solution. use.

SOFTWARE MANUAL CTS700 TOUCH BY NILAN. Compact P / Compact P Polar GEO (English)

Ventilation in balance

Suxess Compact Top HEALTHY INDOOR ENVIRONMENT WITH ENERGY EFFICIENT VENTILATION

Fresh air unit ALB. ALB it s simple and so easy! Air supplied through a heater and filter in a single unit.

AHU N : Range: VERSO VERSO. Heat Recovery Air Handling Units. Plug & Play Energy Saving Smart Design Reliable & Safe

CI/SfB (57.5) November 2008

Series VENTS VUT R WH ЕС

MAKING MODERN LIVING POSSIBLE. Installation Guide. Danfoss Air Units.

Adconair 76. Comfort air conditioning unit with counterflow plate heat exchanger. AIR VOLUME FLOW: 2,600 23,600 m³/h

for a considerable reduction of the supply air temperature which, in turn, reduces the air conditioning

Endura Delta. Demand- and app-controlled ventilation system with heat recovery

CTS 602 by Nilan. Compact P. Compact P Sun. Compact P Cool. Compact P Cool Sun. Version: 5.00, Software-version: 2.11

Small Room Heat Recovery Ventilation

Installation instruction

VERSO DOMEKT. Residential ventilation units m³/h. Non residential ventilation units m³/h

RoofVent Design Handbook

Heat Recovery ventilation Dee Fly Cube 550 Field of application Description Advantages Range Technical details Installation Remote controls Servicing

VENTILATION WITH HEAT RECOVERY

MRXBOXAB-ECO-LP1 100% Typical Installation. (including opposite handed versions)

InspirAIR Home RESIDENTIAL AIR PURIFICATION

EC L2. and humidity sensors. All units are supplied tested and ready to install.

Sentinel Demand Energy Recovery Ventilation

Series. Suspended air supply units with the air capacity up to 4100 m 3 /h in the sound- and heat-insulated casing with the water heater

FRESHBOX 100. Single-room heat recovery unit. Air flow up to 59 CFM Heat recovery efficiency up to 96 %

DEMAND-CONTROLLED HOME VENTILATION

TopVent Design Handbook

MRXBOXAB-ECO4 100% and Opposite Handed version. Typical Installation

290 on. 286 on. Comfortable climate with pre-heated, filtered supply air. Fresh air boxes ALB WW MODEL WITH WARM WATER HEATING

Flexit air handling units C2 and UNI 2, 3,4

MRXBOXAB-ECO3 MRXBOX-ECO3

MRXBOXAB-ECO2 MRXBOX-ECO2

Flexit air handling units UNI 2, 3 og 4

Lo-Carbon Sentinel Kinetic Horizontal

VEX250H with rotary heat exchanger and EXact control system

Auxiliary Equipment and Accessories

OVERVIEW and SYSTEM GUIDE. Swegon CASA. Residential ventilation for optimal operating economy and the greatest comfort.

CONTENT: VEX300C Ceiling units VEX320C/330C

PRODUCT DATA NILAIR BY NILAN. Air distribution. Domestic. Ventilation

Silencer Preheater unit Electric post-heating unit Water circulated post-heating unit CO 2 sensor %RH sensor Pressure difference switch LON converter

TECHNICAL SPECIFICATION

TopMaster Air Handling Unit

RIS V EKO A1/L2 RIS 700 V E L EKO 3.0 AIR HANDLING UNITS. Application

User Manual. Vanvex Optima 180 Domestic Hot Water. Version

Transcription:

PRODUCT DATA COMFORT 40 BY NILAN Ventilation & passive heat recovery Domestic Passive heat recovery Ventilation < 40 m /h

COMFORT 40 Product description The Comfort 40 is an energy-efficient ventilation unit with heat recovery for homes and smaller commercial buildings with a ventilation requirement of up to 40 m /h. This unit has been thoroughly tested, with improvements being continually made during its manufacture for more than years. These have focused on low energy consumption, easy user operation and maintenance. The Comfort 40 is a compact unit which can be ordered as a left- or right-handed model. The Comfort 40 is factory tested and ready for use. Installation and commissioning must be performed by an authorised electrician. The large door provides easy access for changing filters and cleaning the unit. Counterflow heat exchanger made of polystyrene, which has a higher temperature efficiency than aluminium exchangers. The unit comes with a clear and user-friendly operating panel. The modern CTS 02 control panel runs Modbus communication. Intelligent humidity sensors provide an option for controlling the ventilation as required, based on the average air humidity in the home. A CO 2 sensor can be purchased as an accessory. The powder-coated condensate drain prevents the formation of acid water and allows the condensate to be drained away. The efficient fans are powered by energy-saving EC motors. They provide a constant air volume with a four-step adjustment. Filter monitor with timer G4 filters are supplied as standard, but it is also possible to buy a F pollen filter as an accessory. Prepared for an integrated or external water heating element. The automatic bypass damper makes the outdoor air bypass the heat exchanger when heat recovery is not required, thereby saving energy. Bypass cooling as an option. 2

COMFORT 40 BY NILAN Technical specifications Dimensions (W x D x H) 00 x 0 x 40 mm Supply voltage 20 V (±0 %), 0/0 HZ Weight (*) 2/. kg Max. input/power (*) 0 W/2.9 A Plate type casing Aluzinc steel plate Tightness class IP Heat loss casing (*2) 4 W/-4 W Standby power 4 W Heat exchanger type Polystyrene counterflow heat exchanger Power consumption (*&) 980 kwh/year Fan type EC, constant volume Ambient temperature -20/40 C Filter class Standard G4 Duct connections Ø 200 mm Condensate drain PVC, Ø 20. mm External leakage (*) < 0.2 % Internal leakage (*4) < 2. % *. kg is without side plates and exchanger. * 2 4 W: Outdoor air temperature -2 C. Fitting location -2 C. Extract air temperature 20 C (room). -4 W: Outdoor air temperature -2 C. Fitting location 20 C. Extract air temperature 20 C (room). * At ± 20 Pa and 40 m /h according EN 08/EN 4-. * 4 At ± 00 Pa and 40 m /h according EN 08/EN 4-. * Input without heating element (accessory). * Power consumption on continuous operation for system with SFP value.000 J/m at 400 m /h. Dimensional drawing Left model Ø200 00 0 00 0 Ø200 00 Ø0 200 40 4 40 2 4 2 4 2 40 9 9 4 4 0Ø 200 0 Ø200 40 4 2 4 9 2 40 Right model 4 00 9 4 00 9 4 All dimensions are in mm. Connections : Fresh air 2: Supply air : Extract air 4: Discharge air : Condensate drain : Electric and water heating : Primary side (heat exchanger)

PLANNING DATA Nilan units are tested in accordance with the valid standards of accredited independent test institutes. Capacity p t,ext (Pa) Capacity of standard unit as a function of q v and P t, ext. 0 SFP values according to EN 4- are for standard units with G4 filters and without heating element. 00 20 200 SFP values comprise the unit s total power comsumption incl. control. 0 00 000 J/m Max Pa Conversion factor: J/m = W/m /h 00 0 800 J/m 0 20 00 0 400 40 00 0 0 80 90 00 0 20 0 40 0 q v (m /h) q v (l/s) η t (%) Temperature efficiency Temperature efficiency for units with counterflow heat exchanger according to EN08 (dry). 00 98 9 94 92 Temperature efficiency EN08: ɳ t = (t supply air-t fresh air)/(t extract air-t fresh air) 90 88 8 84 82 80 0 0 00 0 200 20 00 0 400 40 q v (m /h) 0 20 40 0 80 00 20 q v (l/s) Sound data Sound data for q V = 00 m /h and P t, ext = 00 Pa according to EN 94-2 for surfaces and EN for ducts. Sound output level L WA drops with falling air volume and falling back pressure. Sound output level L pa at a given distance will depend on acoustic conditions in the place of installation. Sound output level (L WA ) Octave band Hz Surface db(a) Supply air db(a) Extract air db(a) 29 8 2 40 40 20 4 00 4 2 000 40 9 22 2000 29 8 22 4000 8000 4 4 Total ±2 db(a) 48 44 4

COMFORT 40 BY NILAN Capacity - Heating element (accessory) Electrical heating surface The electrical heating surface is fitted in the air inlet duct at a distance of min. 2 x duct diameter from the system s fresh air inlet connection pipe (normally min 20 mm.) and connected to the CTS 02 control panel and power supply. Electric heating element can be ordered for the Comfort 40, with an output of.0 kw (20V). Water heating element for internal fitting The water heating element is designed to be built into the system and must be connected to the primary heating supply and the CTS 02 control. The water heating element includes copper pipes and aluminium fins. Capacities can be seen in the table below. Capacity water heating element Water side Air side Temperature input/output [ C] Flow [m /h] Pressure drop [kpa] Output [kw] Flow [m /h] Temperature before WHE* [ C] Temperature after WHE* [ C] Pressure drop over WHE* [Pa] 0.0. 0. 00 4 2 40/0 0.. 220. 0.4 8.. 0 29. 0.8. 2.0 00 2.9 9 0.0.. 00 48. 2 0/40 0.09.8 2.0 220 4. 0..9 2.8 0 40 0. 0.. 00. 9 0.04 0.8.28 00. 2 0/40 0.0 2. 2.4 220 4. 0.09 4..24 0 4. 0.2. 4.2 00 40. 9 * Water heating element.

AUTOMATION CTS02 Control The Comfort 40 is controlled using its CTS 02 operating panel, featuring a wide range of functions, e.g., menu-controlled operation, weekly programme settings, filter monitor with timer, fan speed adjustment, summer bypass (free cooling), post-heating element control, error messages etc. The CTS 02 comes with factory settings, including a default setting which can be customised to operational requirements to achieve optimum operation and utilisation of the system. The operating panel must be placed in a dry, frost-free location, at least. m above floor level and at least 0. m from any corner. Avoid placing the panel on an external wall or in areas in direct sunlight. Operating instructions for the CTS 02 can be found in a separate user manual supplied with the unit. Functional diagram T8 T T0 4 T4 T9 T2 T 2 TC Connections : Fresh air 2: Supply air : Extract air 4: Discharge air : Condensate drain : Electric and water heating Automation T2/T: Supply air sensor T9/TC: Heating element frost protection T: Extract air sensor T4: Discharge air and defrost sensor T8: Fresh air sensor T0: Room sensor

COMFORT 40 BY NILAN Functional overview Standard - Accessories levels The control function is divided into levels: User/Service/Factory with various options at each level Weekly plan User option The unit has weekly programmes (with a factory setting of off ) Programme : for working families Programme 2: for stay-at-home families Programme : for businesses There is also an option for you to set your own weekly programme. This allows you to override the operating mode in the main menu via an external potential-free contact or PIR sensor. Alarms Alarm log featuring the last alarms. Filter monitor Filter monitor with timer (factory setting of 90 days). Adjustable to 0/90/80/0 days. Bypass Bypassing the outdoor air reduces heat recovery, enabling the desired supply air temperature to be maintained spring, summer and autumn. Air quality Allows you to choose whether to switch humidity sensors and/or CO 2 sensors on and off. /- Humidity control Allows you to set a higher or lower ventilation step in the case of high/low air humidity. CO 2 control Allows you to set a higher or lower ventilation step in the case of a high/low CO 2 level. - Air exchange Allows you to select a low ventilation step in the case of low outside temperatures and air humidity. Defrost function Temperature-based automatic function for defrosting the heat exchanger. Frostprotection Temperature control Room low In case of failing heating system, the unit is turned off to avoid further cooling with a risk of the water heating coil frost bursting. Allows you to select the temperature sensor which will control the unit. T ROOM (panel sensor) T0 EXT (fitted in a representative extraction valve) T EXHAUST (extract air) Stops the unit at a low room temperature. Hereby is cooling of the home avoided in case of a failing central heating system. Standard set to OFF. Can be set from to 20 degrees and is controlled by: T ROOM (panel sensor) T0 EXT (fitted in a representative extraction valve) T EXHAUST (extract air) Room control Allows you to set the regulator to control the room temperature. Air volume Fire alarm Allows you to set four ventilation steps. Supply air and extract air are set individually. Step < 2% - Step 2 < 4% - Step < 0% - Step 4 < 00% This allows you to connect fire-detecting thermostats, smoke detectors and other fire alarm contacts. In case of an alarm, smoke dampers are closed and the unit stops. Joint alarm Outlet for joint alarm Constant pressure control Allows control from both the extract air and supply air side. - Cooling Intake air control External heating element External electric heating element Via bypass. This allows you to choose whether to run the system at a higher or the highest ventilation step during cooling. The weekly programme has an option for setting cooling at night. Allows you to set the regulator to control the intake air temperature/supply air (only available if the control unit has been configured for a supply-heating element). Temperature sensor T is an supply air sensor Integrated frost protection for external water heating element Motorised valve and circulation pump control unit Temperature sensor T is an supply air sensor Overheating protection Delayed start-up There is a possibility for a delayed start-up by the fans, when a closing damper is installed. Expansion PCB Allows you to make additional connections, e.g. User option 2 overrides User option (e.g. connecting an EM box) Up to 00 W direct Can give the signal for external heating if the defrost function is used Switching the central heating system on/off Reset Allows you to restore the factory settings. Manual test Allows you to test the unit s functions manually. Language Option for setting the relevant language (Danish/Finnish/Norwegian/Swedish/German/English/ French). - - -

COMMUNICATION External communication The CTS 02 control unit communicates by default with Modbus RTU RS48 communication. A CTS system using this form of communication can easily be connected to the unit. Nilan units have an open Modbus communication, i.e. not only can the unit be monitored, but its operation can also be set in the same way as it can via the operating panel. CTS / Computer Konverter Modbus The protocol is set up by default for a Modbus RTU 0 address, but can be set to a value between and 24. A Modbus converter allows you to connect one or more units to a computer to monitor and control the unit. OPERATION Intelligent humidity control Nilan s humidity control automatically adapts to the needs of the family or the building. The intelligent CTS 02 control unit does not need to have a set level input for air humidity (RH) to control the air exchange. By using the integrated humidity sensor, the control unit calculates the average level itself for the last 24 hours. The average level provides a basis for deciding whether to change the air exchange if the air humidity fluctuates. This ensures that the unit always runs at its most efficient, based on the actual air humidity level and not on a theoretical one. Immediately change in % of RH 0 9 8 4 2 Reduced ventilation Forced ventilation Normal ventilation This helps save energy because it automatically adapts to the requirements in the home. Whether a large family or a single person is living in the building has a considerable influence on how much humidity is produced. The unit also adjusts automatically to summer and winter level. 0 20 0 40 0 0 0 80 90 00 Average RH (the last 24 hours) If the air humidity changes by more than -0% in relation to the average level, the unit responds with a higher rate of air exchange accordingly. At an air humidity below 0% is reduced ventilation stp activated (adjustable between and 4%) 8

OPERATION COMFORT 40 BY NILAN Frost protection All ventilation units with a counterflow heat exchanger will ice up if the outdoor temperature is below freezing for a prolonged period. ɳt[%] The extracted air condenses when it is cooled down during heat recovery. The high temperature efficiency will slowly turn the condensate to ice, which will block up the counterflow heat exchanger unless action is taken to remedy this. Consideration must be given to whether the unit s operation can be protected during a lengthy period of frost or whether it is acceptable to decrease its operation. Temperature efficiency With pre-heater Defrost function t Außen > - C t Außen < - C In homes which are occupied at night, it would be advisable to protect the unit against frost when the outdoor temperature is coldest by using a pre-heating element. On the other hand, if the ventilation is for an office, it may be acceptable to decrease the operating level at night. Operation Ice building Defrost Ice building Defrost The energy used for the preheating is not wasted, as it ensures a constant high temperature efficiency Frost protection Normal operation No Outdoor temperature < - C After 0 min. Yes Pre-heater installed Yes No Normal operation secured until outdoor temp. < -2 C Defrost function starts when: Outdoor temp < C (T8) Discharge air < C in min. When outdoor temp. < -2 C reduced air volume. Bypass damper opens 2. The intake motor switches off. Warm extracted air will flow through the heat exchanger 4. The ice is melting Defrosting stops when: Discharge air > C (T4) 9

ACCESSORIES CO 2 -sensor With a CO 2 -sensor installed, the ventilation speed can be pre-programmed with CTS02 to run at a higher ventilation steps when CO 2 reaches high level in the extract air. CO 2 -level is programmable. Water heating element incl. regulation The supply temperature can always be raised to the required level using a water heating element. The water heating element is designed to be built into the unit and must be connected to the primary heating supply. Supplied with two-way adjustment valve, temperature sensor and frost thermostat. Electrical heating surface incl. regulation When you fit an electrical heating surface, you can raise the fresh air temperature to the desired level at any time. The electrical heating surface is supplied ready to fit into the fresh air duct and, for easy fitting, the device is pre-fitted with all the required sensors. Electrical pre-heating element (Frost protection) An electrical pre-heating element heats up the outdoor air before it enters the unit. This avoids having to defrost the unit, resulting in a loss of power. There are temperature sensors supplied to be fitted in the ducts. EM-box An EM-box allows heat recovery from the air from the range hood and thereby helps to heat the supply air. The EM-box is equipped with a special filter which efficiently cleans the range hood air of fat particles and thereby protects the system. Expansion PCB The expansion PCB provides additional functions for the CTS 02 control unit, e.g., controlling the EM box (see list of functions on page ). Pollen filter F A pollen filter in class F can be fitted in the unit. The pollen filter is fitted with the G4 plate filter. Installation kit The installation kit comprises of four vibration absorbers and a water trap for the condensation outlet. The water trap can be ordered separately. Heating cable To protect the condensation outlet against frost, a metre-long self-regulating heating cable can be ordered. 0

DELIVERY AND HANDLING COMFORT 40 BY NILAN Transport and storage Comfort 40 comes in factory packaging that protects it during transport and storage. Comfort 40 must be stored in a dry place in its original packaging until installation. The packaging should only be removed immediately prior to installation. Installation conditions During installation, future service and maintenance should be taken into account. We recommend a minimum gap in front of and behind the unit of 0 cm. The unit must be installed level for the sake of the condensate drain. The condensate drain requires clearance of min. 2, cm under the drain nozzle. Min. 0 cm Min. 2, cm Installation of electric heating element Electric heating elements (accessories) are fitted in the duct. The fitter should ensure that there is a safe distance of at least cm between the electric heating element and any inflammable material. The heating element must be insulated using fire-resistant insulation material. The electric heating element must be connected by an authorised electrician. Min. cm Electric pre-heating element with temperature sensor Electric heating element Min. 40 cm Min. 40 cm

INFORMATION FROM A TO Z Nilan develops and manufactures premium-quality, energy-saving ventilation and heat pump solutions that provide a healthy indoor climate and low-level energy consumption with the greatest consideration for the environment. In order to facilitate each step in the construction process from choosing the solution through to planning, installation and maintenance we have created a series of information material which is available for download at www.nilan.dk. Brochure General information about the solution and its benefits. Product data Technical information to ensure correct choice of solution. WWW.NILAN.DK Nilan A/S Nilanvej 2 822 Hedensted DEnmark Tel. 4 2 00 Fax 4 2 2 nilan@nilan.dk www.nilan.dk Installation instructions Detailed guide for installation and initial adjustment of the solution. Visit us at www.nilan.dk to find out User manual Detailed guide for regulation of the solution to ensure optimum day-to-day operation. more about our company and solutions, download further information and find your nearest dealer. Drawings Tender documents and D drawings are available to download for planning purposes. Ver. 2.0-204.2 Nilan A/S assumes no responsibility for any errors or omissions in the printed information material or for loss or damage that may follow from the use of such published materials - whether such loss of damage is caused by errors or inexpediencies in the material or otherwise. Nilan A/S reserves the right without prior notice to change products and information material. All trademarks are the property of Nilan A/S. All rights reserved.