PRODUCT DATA VP 18 BY NILAN. Sanitary hot water production. Heating. Active heat recovery. Comfort heating. Ventilation < 300 m 3 /h.

Similar documents
PRODUCT DATA VPL 15 TOP M2 BY NILAN. Ventilation & active heat recovery. Active heat recovery. Comfort heating. Comfort cooling.

PRODUCT DATA VPL 28 BY NILAN. Ventilation & active heat recovery. Active heat recovery. Comfort heating. Comfort cooling.

PRODUCT DATA COMFORT 600 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 800 m 3 /h

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

PRODUCT DATA COMBI 300 POLAR BY NILAN. Ventilation with passive & active heat recovery. Active heat recovery. Passive heat recovery.

PRODUCT DATA COMPACT S BY NILAN. Sanitary hot water production. Passive heat recovery. Comfort heating. Ventilation < 375 m 3 /h. Active heat recovery

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

PRODUCT DATA COMFORT 300 TOP BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 325 m 3 /h

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

PRODUCT DATA COMFORT 1200 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 1400 m 3 /h

PRODUCT DATA COMFORT 5000 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 5300 m 3 /h

PRODUCT DATA COMFORT 302 TOP BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 345 m 3 /h

PRODUCT DATA NILAIR BY NILAN. Air distribution. Domestic. Ventilation

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

Technical specifications

VENTILATION = WELL-BEING

Comfortable indoor climate regardless of the season

PRODUCT DATA COMPACT P RANGE BY NILAN. Heating. Sanitary hot water production. Ventilation < 300 m 3 /h. Passive heat recovery.

Installation instruction

Air Handling Unit. REC Temovex Blue 4 NEW! Experts on indoor climate in low-energy houses

Installation instruction

Installation instruction

CTS 602 by Nilan. Compact P. Compact P Sun. Compact P Cool. Compact P Cool Sun. Version: 5.00, Software-version: 2.11

eco PREMIUM ENERGY RECOVERY UNIT» Technical instruction

USER MANUAL CTS700 TOUCH BY NILAN. Compact P / Compact P Polar (English)

Air handling unit. REC Temovex 400S-EC-RS. Experts on indoor climate in low-energy houses

Eco Active H E A T R E C O V E R Y S Y S T E M S. Heat Recovery Penthouse Turret. W: T:

THE ROAD TO A HEALTHY INDOOR CLIMATE

Swegon CASA W130. Ventilation unit with counter-flow plate heat exchanger HOME VENTILATION

User Manual. Vanvex Optima 180 Domestic Hot Water. Version

User manual. CTS 602 by Nilan VPL 15 VPL 15 TOP. Version: 9.02, Software-version: 2.21

LZT High efficiency air to water heat pumps with E.V.I. compressors

MAXI CENTRALIZED VENTILATION WITH HEAT RECOVERY

SOFTWARE MANUAL CTS700 TOUCH BY NILAN. Compact P / Compact P Polar GEO (English)

User manual. User manual. CTS 600 by Nilan. Comfort Comfort Version: 10.00, Software-version: 2.30

LZA High efficiency air to water heat pumps with HP compressor

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

NIBE F470 A + Complete heat pump unit that provides heating, hot water, ventilation, heated supply air and heat recovery. Exhaust air heat pump

KOMFORT EC DB Suspended heat recovery air handling units

MRXBOXAB-ECO-LP1 100% Typical Installation. (including opposite handed versions)

Installation Instruction

TURBO HOODS. Product Brochure

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

VERSO DOMEKT. Residential ventilation units m³/h. Non residential ventilation units m³/h

AIR HANDLING UNITS RIS P EKO 3.0. New range - 5 sizes, 20 models! Efficient EC. E f f i c i e n c y up to 94%! E x t r e m e l y low height! fans!

Operation and maintenance instructions

Largo & Allegro. Air Compressors LARGO & ALLEGRO

CRIMSON & CRIMSON MAX

Product Line Introduction. Karl Zhang Technical support engineer

VEX100 series Air handling units with cross-flow heat exchanger

Rollair. Air Compressors. Rollair 15-40E

Largo & Allegro. Air Compressors. Largo & Allegro 31-90

Ducted inverter reverse cycle air conditioning

INSTALLATION INSTRUCTIONS

EC L2. and humidity sensors. All units are supplied tested and ready to install.

FLOWAY. Floway Range. The dual-flow air handling unit with heat recovery guaranteeing an Economical and Durable solution. use.

VERSO Air Handling Units

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

Swegon CASA R120. Ventilation unit with rotary heat exchanger HOME VENTILATION

39HX. High-efficiency dual-flow air handling unit PRODUCT SELECTION DATA. Plug & play unit (built-in control) Class A+ across entire range

TopMaster Air Handling unit. Technical data

KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S. Heat and Energy Recovery Ventilators

AHU Plus. DX Air Handling Units

Rollair. Air Compressors. Rollair 40 to 125 and Rollair 40 V to 125 V

MRXBOXAB-ECO3 MRXBOX-ECO3

Premium Efficiency Heat Recovery Unit. D-AHU Modular L. Air Handling Units

MRXBOXAB-ECO2 MRXBOX-ECO2

Ventilation in balance

Heat and energy recovery ventilators

VERSO Air Handling Units

Adconair 76. Comfort air conditioning unit with counterflow plate heat exchanger. AIR VOLUME FLOW: 2,600 23,600 m³/h

GLOBAL LP. Ceiling-mounted ventilation unit with plate heat exchanger

Zehnder ComfoAir 550. Ventilation unit

EXPLORER HEAT PUMP WATER HEATER. A+ in READY Smart heat pump

VENTS VUT R TN H ЕС VENTS VUT R TN EH ЕС

DVU-HP. Integrated Reversible Heat Pump System

OVERVIEW and SYSTEM GUIDE. Swegon CASA. Residential ventilation for optimal operating economy and the greatest comfort.

CZT CZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSIONS ACCESSORIES

Installation, operation and maintenance guide for window models

TSEK VHR EC HEAT RECOVERY UNITS

Flexit air handling units C2 and UNI 2, 3,4

MRXBOXAB-ECO4 100% and Opposite Handed version. Typical Installation

Aqua 1 plus Air-water heat pumps for domestic hot water production

Horizontal rotor heat recovery ventilation unit RH 5. Vertical rotor heat recovery ventilation unit RV 9

Silencer Preheater unit Electric post-heating unit Water circulated post-heating unit CO 2 sensor %RH sensor Pressure difference switch LON converter

TECHNICAL INFORMATION HCV 4 - HCV 5 - HCH 5 - HCH 8 Demand-controlled home ventilation

w Outdoor Unit w Hydro Indoor Unit w Hot Water Tank *** Projected Availability Q ***

Adsolair 56/58. Comfort air conditioning unit with double plate heat exchanger and adiabatic evaporative cooling system

MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR) NEW ECO RANGE

Technical description. Atec.

UV-TURBO HOODS. Product Brochure

DUCTED AIR CONDITIONER RANGE YOUR COMFORT ZONE.

VEX250H with rotary heat exchanger and EXact control system

Leading edge reverse cycle air conditioning. Ducted and ceiling cassette

Breathe Fresh Air at Home

AIR HANDLING UNITS ver B

Divacondens D Plus Atmospheric condensation wall-mounted boilers, with instant domestic hot water production

RIS V EKO A1/L2 RIS 700 V E L EKO 3.0 AIR HANDLING UNITS. Application

The new Xcell EC High Efficiency Range Fresh air pure and simple

Transcription:

PRODUCT DATA VP 18 BY NILAN Domestic Active heat recovery Ventilation < 300 m 3 /h Comfort heating Comfort cooling Sanitary hot water production Heating

ACTIVE HEAT RECOVERY VP 18 ventilates the home via an active heat recovery function that recovers the energy in the hot air that is extracted from the home, transferring it to the supply air. The center of a ventilation system with active heat recovery is a heat pump that, in general terms, comprises of an evaporator and a condenser. The energy in the hot air extracted from the home is taken up by the evaporator before the air is led outdoors. The condenser then transfers the energy from the evaporator to the cold air intake before it is streamed into the home, thereby eliminating the heat loss. up to 90% of the heat, the heat pump utilises 100% of the heat, both to heat the supply air and to produce hot water. In the summer, the process is reversed from heating to cooling, so that the system cools the fresh summer air flowing into the home. The VP 18 system can cool the air in relation to the outdoor temperature. Due to the low air exchange, VP18 cannot be compared with air conditioning. Besides cooling the air intake, humidity is reduced, ensuring a good comfort level, even with a high indoor temperature. Compared to a counterflow heat exchanger, which recovers Central heating system (only VP 18 EK) The heat from VP 18 EK is used for space heating via a waterborne central heating system (radiators or floor heating system). Supply air Fresh, filtered, temperate air is blown into every room of the home, ensuring a healthy and pleasant indoor climate, 24 hours a day. Extract air The used, moist air is extracted from the home via ceiling valves in all wetrooms, as well as the kitchen. 2

VP 18 BY NILAN Discharge air When the VP 18 system has recovered the heat from the outlet air, the used, moist air is extracted from the home. Fresh air Via an air valve in the home s facade or roof, fresh air is drawn in from the outdoors and channelled to the VP 18 system. VP 18 The unit regulates air flows, heat recovery, production of hot water and any heating of the home that is required. It can be located in a utility or technical room. Sanitary hot water VP 18 recovers the heat from the extracted air and uses it to produce hot water. 3

VP 18 Product description The VP 18 unit is designed for installation in utility or technical rooms and is suitable for homes with an air exchange requirement of up to 300 m 3 /h. The unit combines ventilation with active heat recovery, production of hot water and comfort heating, in one compact, space-saving solution. VP18 VP 18 is the obvious choice for homes with limited space, as it does not require more space than an ordinary wall cabinet. This should be compared to solutions with separate ventilation, heating and hot water installations, which can soon fill up a utility or technical room. A B C D E F G L A 57 db 0 db 2015 812/2013 Dimensional drawing 600 600 600 600 VP 18 = 2000 VP 18 EK = 2200 Connections 1: Fresh air 2: Supply air 3: Extract air 4: Discharge air VP 18 VP 18 EK 4

VP 18 BY NILAN Time-controlled filter change alarm. Easy filter access by opening the top front panel with the help of two finger screws. There is plenty of space to replace filters and to vacuum clean the filter space. Intelligent moisture control. Adapts ventilation to the home s current humidity level. See page 12. CO 2 -sensor can be purchased, for further demand management. A clear, user-friendly operating panel is included. Heating pump with hermetically sealed cooling circuit, for production of hot water and active heat recovery. Hermetically-sealed cooling circuit. The modern CTS 602 control runs Modbus communication. The efficient fans are powered by energysaving EC motors. They provide a constant air volume with a four-step adjustment. The cooling circuit is driven by a reliable piston compressor. Reversible cooling circuit that can also cool the air intake in the summer up to 10 C, with simultaneous hot water production. A powder-coated condensation tray prevents the formation of acid water, leading out the condensation water. VP 18 has an integrated water lock. Electrically monitored sacrificial anode and corrosion protection. 1.5 kw electrical completion. For high hot water consumption where the heating pump cannot cope. 180 l hot water tank. 2 layers of glass enamelling to ensure a long lifetime. The hot water tank is foam-insulated, giving good insulation and saving energy. Attractive white-painted front with large front panels, giving easy access to service the system. Automatic anti-legionella. 5

PLANNING DATA Technical specifications Dimensions (W x D x H) VP 18 600 x 600 x 2000 mm Dimensions (W x D x H) VP 18 EK 600 x 600 x 2200 mm External leakage (*1) < 1,4% Internal leakage (*2) < 1,1% Weight 150 kg Supply voltage 230 V (±10 %), 50/60 HZ Plate type casing Aluzinc steel plate, white powder coating RAL9016 Max. input/power 2,2 kw/ 9,5 A Compressor type Piston compressor Tightness class IP31 Refrigerant R134a, 1000 g Standby power 3 W Fan type Filter class Duct connections Condensate drain EC, constant rotation Standard G4 Ø160 mm PVC, Ø 20 1,5 mm Ambient temperature -20/40 C * 1 At ± 250 Pa and m 3 /h according to EN 308/EN 13141-7. * 2 At ± 100 Pa and m 3 /h according to EN 308/EN 13141-7. Capacity SHW tank Supplementary electrical heating (sanitary hot water) 180 L 1,5 kw Sanitary connection dimension 3/4 Hot water production Consumer profile, water heater L (large) Energy efficiency class Energy efficiency for water heating - average climate Annual electricity consumption - average climate A 118 % Temperature settings on the thermostat 10-65 C Sound power level L WA The water heater can function outside peak load periods (Smart-grid) Guidelines for assembly, installation and maintenance Energy efficiency for water heating - cold climate Energy efficiency for water heating - warm climate Annual electricity production - cold climate Annual electricity consumption - warm climate 57 db(a) No See installation instructions 118 % 118 % A B C D E F G L 57 db A VP18 0 db 2015 812/2013 6

VP 18 BY NILAN Capacity Capacity of standard unit as a function of q v and P t, ext. SFP values according to EN 13141-7 are for standard units with G4 filters and without heating element. SFP values comprise the unit s total power comsumption incl. control. Conversion factor: J/m 3 = W/m 3 /h 3600 P t ext [Pa] 400 300 Max Pa 200 1000 J/m 3 100 800 J/m 3 0 50 100 150 200 250 300 350 400 450 q v [m 3 /h] q v [l/s] 20 40 60 80 100 120 Heat output supply air Heat output Q c [W] as a function of q v [m 3 /h] and outdoor air temperature t 21 [ C]. In accordance with EN 14511, t 11 =21 C (extract air) Heat output is the contribution to room heating added to the fresh air via VP 18 to the supply air. The ventilation loss is the heat output that is lost without heat recovery at the given volume flow air. [W] 2200 Heat Varmeeffekt output 2000 1800 1600 1400 1200 1000 200 m 3 /h 140 m 3 /h 90 m 3 /h 800-5,0 0,0 5,0 10,0 [C ] Outdoor Udetemperatur temperature 7

PLANNING DATA COP (air-air) Heat output factor COP [-] supply air as a function of outdoor temperature t 21 [ C] and volume flow q v [m 3 /h] in accordance with EN14511 at a room temperature t 11 = 21 C [-] 4,0 3,5 3,0 220 m 3 /h COP 2,5 140 m 3 /h 2,0 90 m 3 /h 1,5-5,0 0,0 5,0 10,0 [C ] Außentemperatur Udetemperatur Tapped water Tapped volume in litres V max [L] from VP 18 tank as a function of tapped temperature t [C ] and tank temperature at 40, 50 and 60 C [L] 350 300 250 60 C 200 40 C 50 C 150 35 37,5 40 42,5 45 [ºC] 8

VP 18 BY NILAN COP (air-water) Heat output factor COP [-] and heat output Qw for sanitary hot water as a function of the volume flow q v [m 3 /h] at a tank temperature of 41 C and room temperature t11 = 20 C, outdoor temperature t21 = 20 C in accordance with EN 255-3. 1200 4,00 1100 3,80 1000 3,60 Effekt [W] Output [W] 900 800 Effekt 3,40 3,20 COP 700 3,00 600 COP 2,80 500 50 2,60 100 150 200 250 Volumenstrøm Airflow [m3/h] luft [m 3 /h] Sound data Sounddata is for qv = 210 m 3 /h and Pt, ext = 100 Pa in accordance with EN 9614-2 for surface and EN 5136 for ducts. Sound output level LWA drops with falling air volumes and falling back-pressure. At a given distance, the sound pressure level LpA will depend on the acoustic conditions at the installation site. Sound output level (L wa ) Octave band Hz Surface db(a) Supply air db(a) Extract air db(a) 63-51 38 125-59 46 250-66 51 500-61 41 1.000-56 31 2.000-54 28 4.000-47 20 8.000-40 13 Total ±2 57 69 53 9

AUTOMATION CTS 602 Control The VP 18 is controlled using its CTS 602 operating panel, featuring a wide range of functions, e.g., menu-controlled operation, weekly programme settings, filter monitor with timer, fan speed adjustment, summer bypass (free cooling), post-heating element control, error messages etc. The CTS 602 comes with factory settings, including a default setting which can be customised to operational requirements to achieve optimum operation and utilisation of the system. The operating panel must be placed in a dry, frost-free location, at least 1.5 m above floor level and at least 0.5 m from any corner. Avoid placing the panel on an external wall or in areas in direct sunlight. Operating instructions for the CTS 602 can be found in a separate user manual supplied with the unit. External communication The CTS 602 control unit communicates by default with Modbus RTU RS485 communication. A CTS system using this form of communication can easily be connected to the unit. Nilan units have an open Modbus communication, i.e. not only can the unit be monitored, but its operation can also be set in the same way as it can via the operating panel. CTS / Computer Converter Konverter Modbus The protocol is set up by default for a Modbus RTU 30 address, but can be set to a value between 1 and 247. A Modbus converter allows you to connect one or more units to a computer to monitor and control the unit. 10

VP 18 BY NILAN Functional overview Standard - Accessories 3 levels The control function is divided into 3 levels: User/Service/Factory with various options at each level Weekly plan User option 1 User option 2 The unit has 3 weekly programmes (with a factory setting of off ) Programme 1: for working families Programme 2: for stay-at-home families Programme 3: for businesses There is also an option for you to set your own weekly programme. This allows you to override the operating mode in the main menu via an external potential-free contact or PIR sensor. With an Expansion PCB mounted, allows you to make additional connections, e.g. User option 2 overrides User option 1 (e.g. connecting an EM box) Up to 500 W direct Output relai Switching the central heating system on/off Alarms Alarm log featuring the last 16 alarms. Datalog Possible to log data. Kapacity 46.000 logs Adjustable between 1 and 120 minutes If OFF, only events and alarms are logged Filter monitor Filter monitor with timer (factory setting of 90 days). Adjustable to 30/90/180/360 days. Bypass Bypassing the outdoor air reduces heat recovery when heat recovery are not needed. Air quality Allows you to choose whether to switch humidity sensors and/or CO 2 sensors on and off. /- Humidity control Allows you to set a higher or lower ventilation step in the case of high/low air humidity. Summer/Winter operation Possible to set operation for summer and vinter Winter low Allows you to select a low ventilation step in the case of low outside temperatures Defrost function Temperature-based automatic function for defrosting the heat exchanger. Frostprotection Temperature control Room low Air volume Legionella control In case of failing heating system, the unit is turned off to avoid further cooling with a risk of the water heating coil frost bursting. Allows you to select the temperature sensor which will control the unit. T15 ROOM (panel sensor) T10 EXT (fitted in a representative extraction valve) T3 EXHAUST (extract air) Stops the unit at a low room temperature. Hereby is cooling of the home avoided in case of a failing central heating system. Standard set to OFF. Can be set from 1 to 20 degrees and is controlled by: T15 ROOM (panel sensor) T10 EXT (fitted in a representative extraction valve) T3 EXHAUST (extract air) Allows you to set four ventilation steps. Supply air and extract air are set individually. Step 1 < 25% - Step 2 < 45% - Step 3 < 70% - Step 4 < 100% One weekday can be chosen where the sanitary water temperature is raised to 65 C (e.g. Monday between 1 am to 6 am). External firealarm Possible to connect the unit to external firealarm. Joint alarm Outlet for joint alarm Constant pressure control Allows control from both the extract air and supply air side. - Cooling Intake air control External heating element External electric heating element Via bypass or heat pump. The heat pump has a reversible circuit, which means that the units circuit is reversed and the unit cools, rather than heating, the supply air. It is possible to choose whether the unit is to run a higher or highest ventilation stage during cooling. Via a weekly plan night cooling can be set up. Allows you to set the regulator to control the intake air temperature/supply air (only available if the control unit has been configured for a supply-heating element). Temperature sensor T7 is an supply air sensor Integrated frost protection for external water heating element Motorised valve and circulation pump control unit Temperature sensor T7 is an supply air sensor Overheating protection Delayed start-up There is a possibility for a delayed start-up by the fans, when a closing damper is installed. Reset Allows you to restore the factory settings. Manual test Allows you to test the unit s functions manually. Language Option for setting the relevant language (Danish/Finnish/Norwegian/Swedish/German/English/ French). - - - 11

ACCESSORIES Water heating element incl. regulation The supply temperature can always be raised to the required level using a water heating element. The water heating element is designed to be built into the duct and must be connected to the primary heating supply. Supplied with two-way adjustment valve, temperature sensor and frost thermostat. Electrical heating surface incl. regulation When you fit an electrical heating surface, you can raise the fresh air temperature to the desired level at any time. The electrical heating surface is supplied ready to fit into the fresh air duct and, for easy fitting, the device is pre-fitted with all the required sensors. EM-box An EM-box allows heat recovery from the air from the range hood and thereby helps to heat the supply air. The EM-box is equipped with a special filter which efficiently cleans the range hood air of fat particles and thereby protects the system. Pollen filter F7 A pollen filter class F7 can be fitted in the unit. The pollen filter is fitted with the G4 plate filter. Expansion PCB The expansion PCB provides additional functions for the CTS 602 control unit, e.g., controlling the EM-box (see list of functions on page 11). 12

VP 18 BY NILAN DELIVERY AND HANDLING Transport and storage VP 18 comes in factory packaging that protects it during transport and storage. VP 18 must be stored in a dry place in its original packaging until installation. The packaging should only be removed immediately prior to installation. Installation conditions During installation, future service and maintenance should be taken into account. We recommend a minimum gap in front of and behind the unit of 60 cm. The unit must be installed level for the sake of the condensate drain. Installation of electric heating element Electric heating elements (accessories) are fitted in the duct. The fitter should ensure that there is a safe distance of at least 15 cm between the electric heating element and any inflammable material. The heating element must be insulated using fire-resistant insulation material. The electric heating element must be connected by an authorised electrician. Electric heating element Min. 25 cm 13

VP 18 VARIANTS Solutions The flexible VP 18 series features four different units that can meet any need for ventilation and hot water - from the basic to the more advanced levels. VP18 VP 18 VP 18 is the basic model, with active ventilation of up to 300 m 3 /h and production of hot water in a 180-l tank. This system is described on the preceding pages. A B C D E F G L 57 db A 0 db 2015 812/2013 VP 18 cooling/solar Select VP 18 with cooling and solar function, for cooling of the supply air and if there is a need for extra hot water, e.g. a spa bath. Cooling function A newly built house will be well-sealed and insulated, making it is easy to keep warm, but during hot spells it may be difficult to keep the home cool. The VP 18 cooling function operates via the reversible cooling circuit that can cool the outdoor air by up to 10 C. This is not the same as air conditioning, however, but when the supply air is cooled down, the level of humidity in the home will decrease, making the indoor climate more comfortable. Solar function With the help of an extra heating element, the unit can be connected to a solar panel, oil, gas or other fuel source, to increase the production of hot water. 14

VP 18 BY NILAN VP 18 EK VP 18 EK is a VP 18 unit with a built in 9-kW electrical boiler that is connected to a waterborne central heating system, for electrical heating of the home. One of the big advantages of the VP 18 EK is that it does not require pipes buried in the ground, or the installation of an air extraction heat pump, as in the case of traditional heat-pump based heating solutions. Heat output Supply voltage Fuse size (3 x 230 V) Fuse size (3 x 400 V) Weight Standby power Pressure expansion vessel 9 kw 3 x 230V / 3 x 400V 16A 16A 21 kg 2W 10 l Control CTS 602 VP 18 EK Cooling/solar With VP 18 EK cooling/solar, all solutions are gathered in one unit. Ventilation, hot water and central heating are combined in one unit that does not take up more space than an ordinary wall cabinet. This should be compared to solutions with separate ventilation, heating and hot water installations, which can soon fill up a utility or technical room. Model EK 9 kw EK 9 Condensing boiler No A A A Low temperature boiler No B C D E D B1 boiler No F G Cogeneration space heater No Combination heater No 0 db 9 kw 2015 811/2013 Item Symbol Value Unit Item Symbol Value Unit Rated heat output Prated 8,914 kw Seasonal space heating energy efficiency ŋ s 40 % At rated heat output and high-temperature regime P 4 8,914 kw At rated heat output and high-temperature regime ŋ 4 40 % Other items Standby heat loss P stby 0,0864 kw 15

COMPACT P BY NILAN INFORMATION FROM A TO Z Nilan develops and manufactures premium-quality, energy-saving ventilation and heat pump solutions that provide a healthy indoor climate and low-level energy consumption with the greatest consideration for the environment. In order to facilitate each step in the construction process from choosing the solution through to planning, installation and maintenance we have created a series of information material which is available for download at www.nilan.dk. ONE SYSTEM COUNTLESS FEATURES Heating Hot water Passive heat recovery Compact P Comfort cooling Brochure Active heat recovery Ventilation Comfort heating Compact ventilation and heating solution on only 0.5 m 2 General information about the solution and its benefits. WWW.NILAN.DK Nilan A/S Nilanvej 2 8722 Hedensted Denmark Tel. 45 76 75 25 00 Fax 45 76 75 25 25 nilan@nilan.dk www.nilan.dk Product data Technical information to ensure correct choice of solution. Installation instructions Detailed guide for installation and initial adjustment of the solution. User manual Detailed guide for regulation of the solution to ensure optimum day-to-day operation. Visit us at www.nilan.dk to find out more about our company and solutions, download further information and find your nearest dealer. 600 VP 18 = 2000 Drawings Tender documents and 3D drawings are available to download for planning purposes. 600 Ver. 3.01-2015.11 Nilan A/S påtager sig intet ansvar for eventuelle fejl og mangler i trykt informationsmateriale eller for tab eller skader som følge af det publicerede materiale, hvad enten dette skyldes fejl eller uhensigtsmæssigheder i materialet eller andre årsager. Nilan A/S forbeholder sig ret til uden forudgående varsel at foretage ændringer af produkter og informationsmaterialer. Alle varemærker tilhører Nilan A/S, og alle rettigheder forbeholdes.