T1 Monitor/Module Default Settings

Similar documents
DPM4 Bedside Monitor Default Settings

T1 BEDSIDE MONITOR GUIDELINE

Passport 12m and Passport 17m BEDSIDE MONITOR GUIDELINE 5.21 Software Version NAME: HOSPITAL: DATE: VALIDATOR: Performed

Alarm and Measurement Default Settings

DPM Summary of Features and Benefits

PATIENT MONITORING SYSTEMS

PATIENT MONITORING SYSTEMS

BeneVision Central Monitoring System. Quick Reference Guide

PATIENT MONITORING SYSTEMS

Patient Alarm Messages

HeartStart XL+ Configuration Worksheet

Instructions for Use Vista 120

Multi-Parameter Patient Monitor

OMNI TOUCH SCREEN PATIENT MONITOR

Omni (K) PATIENT MONITOR

PM-9000 Express Portable Patient Monitor

1 Appendix - Product Specifications

Vitalmax 4000 CL Product Specifications

User s Guide. Cardell Touch Veterinary Vital Signs Monitor. For Models:

T1 Patient Monitor. Operator s Manual

Avalon Fetal Monitor

Addendum to the Instructions for Use

Veterinary Portable Multi-parameter Patient Monitor. Operation Manual

Configuration Settings Appendix

5/ 5i/ 5c/ 7/ 7i/ 7c/ 5 elite/ 5i elite/ 5c elite/ 7 elite/ 7i elite/ 7c elite

MRI Patient Monitoring System (Model )

imec8 Vet Portable Multi-Parameter Veterinary Monitor Operator s Manual

Propaq LT Outline Train the Trainer

Clinical Information Center Pro v5 (CIC Pro)

Multiparameter. er Monitor DM

cpm 12/cPM 8 Patient Monitor Operator s Manual

Product Specifications

B40 Patient Monitor. Affordable clinical excellence. Advanced clinical parameters. Ease of use for fast decision-making. Performance and reliability

PAT I E N T M O N I TO R I N G N E T W O R K

GE Healthcare. Dash Variable-Acuity Monitoring

Central Monitor. Central Monitoring System. Intuitive, Reliable, Flexible CNS-9601K. Shown with options

Patient Monitor CM400PC Monitoring Module

BM3VET User Manual Code Veterinary Monitor Rev. 2.4

Multi-parameter Veterinary Monitor. User Manual

M8000VET /M9000VET Veterinary Monitor User s Manual

Meditec M700 Series Patient Monitors

Capnostream 20p Bedside Capnography Monitor. The only integrated, complete picture of oxygenation and ventilation 1

Atlas Monitor Outline Train the Trainer

Infinity M300 Patient Worn Monitoring

INSTRUCTIONS FOR USE. IntelliVue Patient Monitor. MP5 Release G.0 with Software Revision G.0x.xx. Patient Monitoring

Menntor X7 Specification

OPERATOR S MANUAL. Patient Monitor M20. EU representative TECNOMED 2000 S.L. Valencia, Madrid Spain

Revision History WARNING

INSTRUCTIONS FOR USE. IntelliVue X2. Multi-Measurement Module Release G.0 with Software Revision G.0x.xx. Patient Monitoring

Manufacturer s Responsibility Only under the following circumstances will manufacturer be responsible for the safety, reliability and performance of t

Multi-parameter Patient Monitor STAR8000H. User Manual

OPERATOR S MANUAL. NPB-4000/4000C Patient Monitor

PM Portable Multi-parameter Patient Monitor. Operation Manual

GE Healthcare. Quick Guide. Dash 2500 Patient Monitor

HeartStart XL+ User Training Workbook. Model No

BeneVision TM80 Telemetry Monitor

SOFTWARE VERSION 8.5 FAQs

General Skills. yes. Device controls, buttons, indicators, and connectors

Transport Pro Patient Monitor Operator s Manual Software Version 2.1

L505. Patient monitor user manual. Technology that doesn t miss a beat. Tel:

QAM.L L550 series. Patient Monitor Manual QAM.L

M9500 Patient Monitor User s Manual

Operating Instructions. Passport _PPV ops color.indd 1

Infinity M300+ Telemetry

GE Healthcare Healthcare Systems 9900 Innovation Drive Wauwatosa, WI USA

THE CLINICAL CONNECTION

SERVICE MANUAL YM6000 Patient Monitor

The information in this document is subject to change without notice.

SPECIFICATION FOR MULTIPARAMETER MONITOR

End-Tidal CO2 User Guide CAPNO3 T NIBP. SpO2. Ver Charmcare Co., Ltd.

740 SELECT. Multi-Parameter Monitor

BeneView T5/ BeneView T8. Patient Monitor. Operator s Manual

SECTION L MONITORING EQUIPMENT

P/N: Release Date: January 2012 Copyright EDAN INSTRUMENTS, INC All rights reserved.

BEDSIDE MONITORING Dash 3000/4000 V5

"It's Alarming Simple Steps To Reduce Nuisance Alarms

ARGUS LCM. Patient monitor ARGUS LCM and ARGUS LCM PLUS. Service Handbook. Art. no.: rev.: d

www. szcomen. com COMEN - SHARE WITH THE WORLD

Accutorr 7. Vital Signs Monitor. Operator s Manual

Nellcor Bedside SpO 2 Patient Monitoring System, PM100N

B40/B20 Patient Monitor User's Guide. English E (Paper) 21 November General Electric Company. All rights reserved.

VS2000V Veterinary Vital Signs Monitor Operation Manual

İndex SUCTION UNIT... PATIENT MONITOR HOLTER SYSTEM... 7

DPM 4 Patient Monitor. Operator s Manual

Vital Signs Monitor. Operator s Manual

Quick start guide. English

Central Monitor CNS Shown with options

HBP Patient Monitor. Operator s Manual. EU representative OBELIS S.A Bd. Général Wahis, Brussels, Belgium.

SECTION L MONITORING EQUIPMENT

Ultraview SL2400 With Wireless-LAN-Option

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless testing requires power.

ncompass 8100H Series Vital Signs Monitor Operator s Manual

Checkout Procedure Manual

Ultraview SL Command Module Parameter Set ECG NIBP TEMP IP CO SpO2 Options SL Command Module: A B Our goals are simple:

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless testing requires power.

PM-9000Vet Veterinary Portable Multi-Parameter Patient Monitor. Operator s Manual

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless testing requires power.

SERVICE MANUAL. Patient Monitor M30. EU representative TECNOMED 2000 S.L. Valencia, Madrid Spain

OMNI. Patient Monitor USER S MANUAL

HOLTER RECORDER Product parameters

Transcription:

Hospital, City, ST Department Clinical/Sales/Service Representatives Date Software Version Signature,Title Maintenance System time Date format: Time format: 12 24 Manage Config Department: General Select default: Load latest Load specific User config: User config: User config: User Maintenance Facility Room Change Pt Loc Monitor name Visit # Dept Bed On Off Language: English On Off Units Ht In Cm CVP mmhg kpa cm/h2o Wt Lbs Kg CO2 mmhg kpa % ST mm mv O2 mmhg kpa % Pressure mmhg kpa Temp F C Network Setup Select CMS Off On Central station setup: Network Encryption On Off Alarm Setup Min Alarm Vol ECG Lead off level Low Med High Alarm Pause SpO2 sensor off level Low Med High Alarm Sounds ISO Mode1 Mode2 IBP sensor off level Low Med High High Interval Lethal Arr off Disable Enable Med Interval Extended arrh Disable Enable Low Interval Alarm light on Alarm Reset On Off Reset Other Bed s alarms On Off Alarm delay Alarm reset by other bed On Off ST alarm delay Other bed disconnect On Off Latching Alarms: Lethal Visual Audible Reminder Interval 1 min 2min 3min High Visual Audible Reminder tone On Off Re-alarm Medium Visual Audible Low Visual Audible Vtach Latch lock: Disable Enable Others Wave line Thin Med Thick SpO2 tone: Mode1 Mode 2 Outdoor Mode Manual Auto Clear CMS IP at start up On Off ECG standard: AHA Notch Freq 60 50 Data transfer: USB Off Transfer data length: 1h 2h 4h 8h all Maintenance Central Hypervisor Panorama Network setup: HR alarm delay On Off Dock Setup Work Mode: Dock Host Network type: Use Current T1 Use Current Dock Config-influenced settings: Param switch On Presence mode: Broadcast HL7 Compatibility On Off Multicast Off P/N: 002-08-30039 Rev B Page 1 of 9

Alarm Setup See Configurations Review Group: Standard Other Graphic Trends Zoom: 3min 15min 30min 90min 3h 6h 12h 24hr Waves: 1 2 Group: Standard Other Tabular Trends Interval: 5s 30s 1min 5min 10min 15min 30min 1hr 2hr 3hr NIBP Full Disclosure Saved waves: Beat Annotation On Off Screen Setup Key Volume (1-10) Brightness (1-10) Screen Layout (Normal/Big Numeric Setup--see Configurations) *12 Lead Setup Filter: Diagnostic ST 12 Lead Report Setup Measurement Color Setup White Gray 1-3 Red, 1-3 Orange, 1-3 Yellow. 1-3 Green, 1-3 Cyan, 1-3 Blue, 1-3 Purple, 1-3 Night Mode: Baseline Drift: On Off Tachy High Brady Low QTc Formula: Hodges Bazett Fridericia Framingham Waveform Layout: Standard Cabrera Format: 12x1 6x2 3x4+1 Median Complex: On Off Measurements: On Off Interpretation: On Off Interp Summary: On Off Parameter Color default Adu Ped Neo ECG SPO2 P1 P2 Resp *CO2 NIBP Temp Brightness Volume: Alm QRS Key NIBP End tone: On Off Stop NIBP: Print Setup ECG Reports Normal End of Case Yes No Tabular Trends Reports Amplitude 5mm 10mm 20mm 5mm 10mm 20mm Sweep 25mm/s 50mm/s 25mm/s 50mm/s Auto Interval On Off On Off 12 Lead 12x1 6x2 3x4+1 12x1 6x2 3x4+1 Normal End of Case Yes No Back 30min 1hr 2hr 3hr 6hr 12hr 24hr 48h 72hr 96hr Auto All Spacing 1min 5min 10min 15min 30min 1hr 2hr 3hr NIBP Auto 30min 1hr 2hr 3hr 6hr 12hr 24hr 48h 72hr 96hr Auto All 1min 5min 10min 15min 30min 1hr 2hr 3hr NIBP Auto Report layout Parameter oriented Time oriented Parameter oriented Time oriented Select Currently displayed Standard group Currently displayed Standard group parameters P/N: 002-08-30039 Rev B *Optional Page 2 of 9

Graphic Trends Reports Realtime Reports Back T1 Monitor/Module Default Settings Normal End of Case Yes No 30min 1hr 2hr 3hr 6hr 12hr 24hr 48h 72hr 96hr Auto All 30min 1hr 2hr 3hr 6hr 12hr 24hr 48h 72hr 96hr Auto All Paginal Time 3hr 6hr 12hr 24hr All 3hr 6hr 12hr 24hr All Report layout Parameter oriented Time oriented Parameter oriented Time oriented Currently displayed Standard group Currently displayed Standard group Select parameters Sweep Select Wave Normal End of Case Yes No 12.5mm/s 25mm/s 50mm/s Auto 12.5mm/s 25mm/s 50mm/s Auto Current Current Select waves List: Select waves List: Print Setup Mark Event Waveforms Parameters ECG Setup Printer Paper Size A4 Letter Print Both Sides On Off Wave 1 Wave 2 Wave 3 Alm Source ECG1 ECG2 ECG1Gain ECG2Gain Filter Diagnostic Monitor Surgery ST Arrhythmia analysis See alarm setup ST analysis On Off QT analysis On Off Formula: Lead All Single: Others QRS Vol (0-10) Lead Set Adu: Auto 3 5 12 Ped: Neo: ECG Display Normal Full screen Half screen Notch Filter Off Weak Strong Paced No Yes Pacer Reject On Off Pace Rate(40-100) Smart Lead Off On Off QRS Threshold Resp Setup Apnea Delay Adu: 10 15 20 25 30 35 40 Ped: Neo: Resp Lead Adu: I II Auto Ped: Neo: Gain Sweep 3mm/s 6.25mm/s 12.5mm/s 25mm/s 50mm/s RR Source Auto ECG CO2 Detection mode Auto Manual P/N: 002-08-30039 Rev B *Optional Page 3 of 9

Parameter s cont d SpO2 Setup Massimo Nellcor Avg time (sec): 2-4 4-6 8 10 12 14 16 Sat Sec: 0 10 25 50 100 Sensitivity Mode: High Normal NIBP Simul On Off PR source SpO2 IBP Art Auto Alm source HR PR Auto Beat vol (0-10) NIBP Setup Initial Pressure Adu: Ped: Neo: Interval Adu: Manual 1m 2m 2.5m 3m 5m 10m 15m 20m 30m 1h 1.5h 2h 3h 4h 8h Ped: Neo: End tone On Off Clock On Off Venipuncture Adu: Ped: Neo: P1 Setup P2 Setup *CO2 Setup Label Scale Auto Manual Upper Lower Filter 8Hz 12.5Hz 20Hz 40Hz Sensitivity High Med Low PPV On Off Source: Label Scale Auto Manual Upper Lower Filter 8Hz 12.5Hz 20Hz 40Hz Sensitivity High Med Low PPV On Off Source: Apnea Delay Adu: 10 15 20 25 30 35 40 Ped: Neo: BTPS Comp On Off O2 Comp Sidestream N2O Comp Des Comp Flow Rate 70 100 120 150 (ml/min) Oridion Max Hold Single 10 20 30 Op mode Standby Measure Wave type Draw Fill Scale mmhg kpa % RR source Auto ECG CO2 Auto Standby Off 15min 30min 60min P/N: 002-08-30039 Rev B *Optional Page 4 of 9

Configuration Name T1 Monitor/Module Default Settings (Adu) Alarm Setup: Alarm report attached Parameter *On/Off High Low Level Record Other *On/Off High Low Level Record HR/PR *ST I Ext Tachy *ST II Ext Brady *ST III QTc *ST avr ΔQTc *ST avl Resp *ST avf SpO2 *ST V1 Desat *ST V2 NIBP-S *ST V3 NIBP-D *ST V4 NIBP-M *ST V5 T1 *ST V6 T2 *EtCO2 TD *FiCO2 P1-S P1-D P1-M P2-S P2-D P2-M *Arrhythmia On/Off Level Rec *Arrhythmia On/Off Level Rec *Arrhythmia Threshold Asystole Bigeminy PVC s High VT/VFib Trigeminy Extreme Tachy VTach Tachy Tachy (HR High) *VBrady Brady Brady (HR low) *Extreme Tachy *PNP Extreme Brady *ExtremeBrady *PNC Asys delay PVC s/min Missed Beat Multi PVC R on T *Nonsust VT VTach rate *Run PVCs Vent Rhythm VTach PVCs Couplet *Pause Pause time Multi PVC *AFib VBrady rate *PVC Irr Rhythm VBrady PVCs Others Alm Vol (1-10) High: Alm Vol + 0 1 2 Reminder Vol High Med Low Record length 8s 16s 32s Apnea delay Tech delay Off 5s 10s 15s Vtac Latching On Off P/N: 002-08-30039 Rev B *Optional Page 5 of 9

Configuration Name T1 Monitor/Module Default Settings (Ped) Alarm Setup: Alarm report attached Parameter *On/Off High Low Level Record Other *On/Off High Low Level Record HR/PR *ST I Ext Tachy *ST II Ext Brady *ST III QTc *ST avr ΔQTc *ST avl Resp *ST avf SpO2 *ST V1 Desat *ST V2 NIBP-S *ST V3 NIBP-D *ST V4 NIBP-M *ST V5 T1 *ST V6 T2 *EtCO2 TD *FiCO2 P1-S P1-D P1-M P2-S P2-D P2-M *Arrhythmia On/Off Level Rec *Arrhythmia On/Off Level Rec *Arrhythmia Threshold Asystole Bigeminy PVC s High VT/VFib Trigeminy Extreme Tachy VTach Tachy Tachy (HR High) *VBrady Brady Brady (HR low) *Extreme Tachy *PNP Extreme Brady *ExtremeBrady *PNC Asys delay PVC s/min Missed Beat Multi PVC R on T *Nonsust VT VTach rate *Run PVCs Vent Rhythm VTach PVCs Couplet *Pause Pause time Multi PVC Irr Rhythm VBrady rate *PVC *AFib VBrady PVCs Others Alm Vol (1-10) High: Alm Vol + 0 1 2 Reminder Vol High Med Low Record length 8s 16s 32s Apnea delay Tech delay Off 5s 10s 15s Vtac Latching On Off P/N: 002-08-30039 Rev B *Optional Page 6 of 9

Configuration Name Alarm Setup: Alarm report attached Parameter *On/Off High Low Level Record Other *On/Off High Low Level Record HR/PR *ST I Ext Tachy *ST II Ext Brady *ST III QTc *ST avr ΔQTc *ST avl Resp *ST avf SpO2 *ST V1 Desat *ST V2 NIBP-S *ST V3 NIBP-D *ST V4 NIBP-M *ST V5 T1 *ST V6 T2 *EtCO2 TD *FiCO2 P1-S P1-D P1-M P2-S P2-D P2-M *Arrhythmia On/Off Level Rec *Arrhythmia On/Off Level Rec *Arrhythmia Threshold Asystole Bigeminy PVC s High VT/VFib Trigeminy Extreme Tachy VTach Tachy Tachy (HR High) *VBrady Brady Brady (HR low) *Extreme Tachy *PNP Extreme Brady *ExtremeBrady *PNC Asys delay PVC s/min Missed Beat Multi PVC R on T *Nonsust VT VTach rate *Run PVCs Vent Rhythm VTach PVCs Couplet *Pause Pause time Multi PVC Irr Rhythm VBrady rate *PVC *AFib VBrady PVCs Others Alm Vol (1-10) High: Alm Vol + 0 1 2 Reminder Vol High Med Low Record length 8s 16s 32s Apnea delay Tech delay Off 5s 10s 15s Vtac Latching On Off P/N: 002-08-30039 Rev B *Optional Page 7 of 9

Screen Setup Choose Screen Normal Screen Setup T1 Monitor/Module Default Settings Normal Big Numerics ECG 7 Lead Full Wave 1 ECG 1 Wave 2 T1 Wave 3 Wave 4 Parameters Big Numerics Param 1 Param 3 Parameters All On Switch Parameters-- see above External Display Normal Screen Setup Param 2 Param 4 19 Display On except (List): Wave 1 ECG 1 Wave 2 Wave 3 Wave 4 Wave 5 Wave 6 Wave 7 Parameters Quick Keys First Page Second Page Display Screen Power Locked OSD Locked P/N: 002-08-30039 Rev B *Optional Page 8 of 9

Mindray DS USA, Inc. Document Revision DESCRIPTION: T1 Default Settings DOCUMENT NO: 0002-08-30039 REVISION: B SHEET 9 of 9 REV. CR NO. & DESCRIPTION LETTER EFF. DATE A CR 42661 Original Release as Rev A 01/29/2016 B CR 44320 Update to Rev B P/N: 002-08-30039 Rev B *Optional Page 9 of 9