DRAWING SCHEDULE TAB REQUIREMENTS BY EQUIPMENT TYPE TYPE OF EQUIPMENT DESCRIPTION COMPONENT TAB REQUIREMENTS

Similar documents
SHOE PALACE HUNTINGTON PARK M.200

Project General Notes DESCRIPTION ABBREVIATIONS AIR CONDITIONER ABOVE FINISHED FLOOR BALANCING DAMPER

HWC NOTES: CONTRACTOR SHALL REFER TO ARCHITECTURAL DRAWINGS FOR MOUNT HEIGHTS AND SPECIAL MOUNTING INSTRUCTION AND LIMITATIONS.

LAV FCO WCO NOTES: CONTRACTOR SHALL REFER TO ARCHITECTURAL DRAWINGS FOR MOUNT HEIGHTS AND SPECIAL MOUNTING INSTRUCTION AND LIMITATIONS.

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Plumbing Standards

GRILLE, REGISTER AND DIFFUSER SCHEDULE

COMcheck Software Version Interior Lighting Compliance Certificate


University of Rochester October 17, 2008 Brooks Landing Business Center


EXHAUST FAN SCHEDULE

HVAC LEGEND HVAC ABBREVIATIONS PLUMBING LEGEND PLUMBING ABBREVIATIONS PRELIMINARY NOT FOR CONSTRUCTION

GENERAL PLUMBING NOTES

Mechanical/Plumbing Specification

Technical Assignment 3 11/15/04. Executive Summary

GENERAL PLUMBING NOTES 6. ALL RISES AND DROPS IN PIPING ARE NOT NECESSARILY SHOWN

REFRIGERANT PIPING (LINE SET) CONDENSATE DRAIN PIPING SIDE WALL RETURN GRILLE AIR DEVICE TYPE AND SIZE SIDE WALL SUPPLY GRILLE CONNECT TO EXISTING

PLUMBING STEAM PIPING RADIATION SYMBOLS ABBREVIATIONS GENERAL NOTES T CSW HSW HSWR NPW G A D WW GM WM HOT WATER HOT WATER RETURN HOT W

DESIGN STANDARDS SECTION PLUMBING FIXTURES AND EQUIPMENT. 1.3 Wall hung toilet room fixtures. Urinals for handicapped may be stall type.

JAMES P. KISSANE, ARCHITECT

FAARM-Underground Facility. Conceptual Design Review. Mechanical Systems. Dunham Associates, Inc.

SECTION PLUMBING FIXTURES AND TRIM. A. Types of plumbing fixtures required for the project include the following:

MONROE MIDDLE SCHOOL SCHOOL

Heat Recovery Units. EXTERNAL STATIC REQUIRED (in.h2o) (Pa) MOTOR (Bhp/Hp) (bkw/kw) SPEED (rpm)

R7DA Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units

Florida Department of Transportation

Mechanical System Description

DESIGN STANDARDS SECTION Toilet rooms and utility rooms to have floor drains at lowest point.

AIR HANDLING UNITS ASSET REFERENCE: DESIGN AHU 1 AHU 2

ADDENDUM #2. BIDS CLOSE TUESDAY, May 8, 2018 at 1:00 p.m. (C.D.T.)

Product Data. FF1DNA, FF1DNE Fan Coil Units. Sizes 018 thru 030 FEATURES/BENEFITS

SECTION SPECIFICATION FOR HI-VELOCITY FAN COIL SYSTEMS

Ventilation Requirements Schedule SCHEDULE BASED ON IMC 2009

HVAC Project Westmoreland County Courthouse. 2 N. Main Street Greensburg, Pa SITE SITE NORTH NORTH. Elevation. Mark. Section. Mark.

ASHRAE 90.1 EFFICIENCY PACKAGE AIR CONDITIONER UNIT MBtuh

System Components with ` Emphasis on Packaged Rooftop Application and Installation. Jerry Cohen President Jacco & Assoc.

Genevieve Melody Elementary School

A. Section Joint Sealants: Seal fixtures to walls and floors.

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

EXIST 54"x64"x3" CONCRETE HOUSEKEEPING PAD. RL RL RL RL RS RS RS RS ROUTE REFRIGERANT PIPING UNDER OVERHANG ABV.

CHAPTER IV AIR DISTRIBUTION AND BALANCE

Josefa Ortiz De Dominguez Elementary School

SECTION DUCTWORK

SECTION AIR DUCT ACCESSORIES


SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED

Civil Engineering Building

Agustin Lara Elementary Academy

Technical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ)

48GS HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS

50HS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP UNITS W/OPTIONAL ELECTRIC HEAT

PLUMBING FIXTURES, TRIM, AND SUPPORTS

Ho-Chunk Gaming THUNDERBIRD ENGINEERING, INC. MILWAUKEE: (414) MADISON: (608)

Cabinet Features Heavy-gauge, galvanized-steel cabinet with UV-resistant powder-paint finish Full Perimeter Rail Sloped drain pan

Edward Jenner Elementary Academy of the Arts

Architectural Alliance Incorporated MDP CONSULTING ENGINEERS, INC N 11th Street Beaumont, TX 77702

Fan Power in 90.1 & IECC

Modular Heating & Ventilating Unit Model IGX-HV

DCC Commercial. Submittal Data Form. 7½ - 12½ Ton Packaged Air Conditioners Up to 11.3 EER Cooling Capacity: 88, ,000 BTU/h

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series

15 SEER, PACKAGE AIR CONDITIONING UNITS, 2-5 TONS Single Phase, 208/230 V, 60 Hz COOLING

PAR5. Product Specifications

THIS IS A DESIGN GUIDE NOT A SPECIFICATION. Montgomery County Public Schools Facilities Guide DIVISION 15 MECHANICAL

Technical Development Program

Joseph Brennemann Elementary School

SECTION PLUMBING

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.

Tighe&Bond. Groton Heights School Mechanical Evaluation. 1 Existing Conditions. 1.1 Water Service Entrance

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

COMcheck Software Version Mechanical Compliance Certificate

A. All fixtures shall meet the requirements of ANSI A117.1, ANSI Z124.2 and the State of Texas Accessibility Standards (TAS).

Mechanical Inspection Plumbing

DCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners

Outside Air Requirements... SOLVED!

DESIGN STANDARDS SECTION Toilet rooms and utility rooms to have floor drains at lowest point.

HU, HCF, HCR Unit Heaters Technical Guide

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise VAV Terminal Units Full Spec. Prepared by: Phone Number: Prepared for:

Unico Training. Class for R E Michel Salesmen

50TM COMBINATION HEATING/COOLING UNITS

Advance Release September 2009

CORRALES INTERNATIONAL SCHOOL TENANT IMPROVEMENT 5500 WILSHIRE AVE NE ALBUQUERQUE, NM 87113

DCG Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners

SEQUENCE OF OPERATION FOR ALC CONTROL AIR SOURCE HEATPUMP RECIRCULATION AIR WITH ECONOMIZER

Product Data. Features/Benefits. 50HX High Efficiency Single-Packaged Heat Pumps. 2 to 5 Nominal Tons

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

TECHNICAL SPECIFICATIONS

City of Duluth Festival Center 04/25

MID MICHIGAN COMMUNITY COLLEGE HARRISON CAMPUS Harrison, Michigan 2015 MASTER PLAN

John Palmer Elementary School

CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L2EU NOMINAL TONS

Charles W Earle Elementary School

48GS(N) STANDARD EFFICIENCY 48GX(N) HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING ELECTRIC COOLING UNITS

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS

CLIMATAIR PENTHOUSE AIR HANDLING SYSTEMS

G101 SCHOOL AIR CONDITIONING UPGRADE - PROJECT #3 SUNSET ELEMENTARY COOLING UPGRADE 2014 NORTH 250 WEST SUNSET, UTAH 84015

Dates of Construction Construction Start 2/28/1999 Date of Completion 4/2000 Occupancy 5/2000

SEQUENCE OF OPERATION FOR ALC CONTROL AIR SOURCE HEATPUMP 100% OUTSIDE AIR

JH Series Installation

Now In Production JULY 2008

Indirect Gas-Fired Make-Up Air

Transcription:

DRAWING SCHEDULE NUMBER TITLE M0-1 MECHANICAL NOTES AND LEGEND M1-0 MECHANICAL FLOOR PLAN M4-0 MECHANICAL SCHEDULES M4-1 MECHANICAL LOAD CALCULATIONS M5-0 MECHANICAL DETAILS M8-0 TCS BASYS CONTROLS DRAWINGS AND SEQUENCE OF OPERATION P1-0 PLUMBING PLAN, NOTES, AND LEGEND P1-1 PLUMBING PLAN, RISERS, AND SCHEDULES P5-0 PLUMBING DETAILS F1-0 FIRE SPRINKLER PLAN MPF13-0 MECHANICAL SPECIFICATIONS MPF13-1 MECHANICAL SPECIFICATIONS MPF13-2 MECHANICAL SPECIFICATIONS TYPE OF EQUIPMENT RTU UH, EWH EF or F Ductwork Diffusers DESCRIPTION COMPONENT TAB REQUIREMENTS Rooftop Unit Unit Heater, Electric Wall Heater Exhaust Fan or Fan (any type) TAB REQUIREMENTS BY EQUIPMENT TYPE Entering Air Temp Heater DX Cooling Coil Heating Mode At each branch and/or fitting Airflow at each Diffuser with referenced Mechanical drawing(s) Airflow EAT LAT LAT Supply Air CFM Minimum Outside Air CFM 100% Open Economizer Airflow CFM HP RPM External Static Pressure (+/-) Voltage/Phase Amps LAT HP Voltage/Phase Amps Duct Size Duct CFM Duct Velocity CFM CFM HP External Static Pressure (+/-) RPM Voltage/Phase NOTE: REFER TO SPECIFICATIONS FOR ADDITIONAL INFORMATION AND REQUIREMENTS AS RELATED TO TEST AND BALANCE. Fan Electrical Electrical

AIR DISTRIBUTION DEVICE SCHEDULE MARK MANUFACTURER MODEL TYPE NECK SIZE FACE SIZE FRAME FINISH MATERIAL ACCESSORIES (L" X W" OR (L" X W") TYPE DIAMETER") SD-1 (1) (1) PLAQUE FACE 12" 24 X 24 (1) (1) STEEL PFS, DMPR REMARKS RD-1 (2) (2) PLAQUE FACE 12" 24 X 24 (2) (2) STEEL PFS, DMPR TG-1 (3) (3) WALL TRANSFER GRILLE 48 X 12 - (3) (3) STEEL - RG-1 (3) (3) WALL RETURN GRILLE 12 X 12 - (3) (3) STEEL - EG-1 (3) (3) WALL EXHAUST GRILLE 8 X 8 - (3) (3) STEEL - SR-1 (4) (4) DUCT SUPPLY GRILLE 33 X 6 - (4) (4) STEEL DMPR SR-2 (4) (4) DUCT SUPPLY GRILLE 21 X 6 - (4) (4) STEEL DMPR SR-3 (4) (4) DUCT SUPPLY GRILLE 13 X 6 - (4) (4) STEEL DMPR SR-4 (5) (5) DUCT SUPPLY GRILLE 16 X 6 - (5) (5) STEEL DMPR SR-5 (5) (5) DUCT SUPPLY GRILLE 18 X 6 - (5) (5) STEEL DMPR SR-6 (5) (5) DUCT SUPPLY GRILLE 14 X 6 - (5) (5) STEEL DMPR SR-7 (5) (5) DUCT SUPPLY GRILLE 6 X 6 - (5) (5) STEEL DMPR EG-2 (6) (6) EXHAUST GRILLE 8 X 8 - (6) (6) ALUMINUM DMPR ACCESSORIES: REMARKS: PFS-PLASTER FRAME DMPR- DAMPER EXT-LINDAB AIR EXTRACTOR AS-PRICE AIR SCOOP KEY MARK MANUF MODEL FRAME ACCESSORIES FINISH REMARKS NOTE TYPE DAMPER PLASTER FRAME KRUEGER PLQ 23 PRN-100 5HCF23 BRITISH WHITE FOUR WAY BLOW PATTERN (1) SD-1 PRICE SPD 31 VCR-7 AMF B12 TITUS OMNI 3 AG-75 TRM 26 KRUEGER PLQ 23 PRN-100 5HCF23 BRITISH WHITE (2) RD-1 PRICE SPD 31 VCR-7 AMF B12 TITUS OMNI 3 AG-75 TRM 26 KRUEGER S85 SURFACE - - BRITISH WHITE (3) TG-1/RG-1/EG-1 PRICE 535 SURFACE - - B12 TITUS 25RL SURFACE - - 26 (4) (5) SR-1/SR-2/ SR-3 SR-4/SR-5/ SR-6/SR-7 (6) EG-2 LINDAB RGS-3 DUCT EXT - GALVANIZED 'EXT' IS THE AIR EXTRACTOR - - - - - - - - - - - - KRUEGER 880H DUCT OBD - BRITISH WHITE ONLY USE FOR RECTANGULAR DUCTWORK PRICE 520L DUCT D - B12 ONLY USE FOR RECTANGULAR DUCTWORK TITUS 300RL DUCT AG-15-26 ONLY USE FOR RECTANGULAR DUCTWORK - - - - - - - - - - - - TITUS 50F SURFACE AG-15 PFA 26 OPTIONAL CORE; 1/2''x1/2''x1'' FAN SCHEDULE ELECTRICAL OPER MARK MFR MODEL CFM S.P. H.P. VOLT/PH/HZ WT REMARKS (IN W.G.) (WATTS) (LBS) EF-1 LOREN COOK 70 SQN-B 170 0.625 1/4 120/1/60 80 1,2 EF-2 BROAN QTXE150 150 0.100 (51.3) 120/1/60 12 3 REMARKS: 1 PROVIDE WITH FACTORY MOUNTED DISCONNECT SWITCH AND BACKDRAFT DAMPER. 2 EXHAUST FAN TO BE CONTROLLED THRU SCENE 2 CONTROLLER. REFER TO ELECTRICAL DRAWINGS. 3 EF SHALL RUN 24-7 AT CONSTANT SPEED. OUTSIDE AIR REQUIREMENTS ROOM ROOM UNIT GROSS FMC - 2010 FMC - 2010 ZONE ACTUAL PURPOSE CLASSIFICATION SERVED FLOOR AREA OA RATE/ DEFAULT PEOPLE OA RATE/ AIR TOTAL SYSTEM OUTSIDE REMARKS AREA REQUIREMENTS OCCUPANCY REQUIREMENTS DISTRIBUTION OA REQ'D NUMBER AIR (SQ. FT.) (CFM/SF) (CFM) (#/1000 S.F.) (# PEOPLE) (CFM/PER.) (CFM) EFFECTIVENESS (CFM) (CFM) 1.00 DISPLAY AREA SALES RTU-1 178 0.12 21 15 3 7.5 20 0.8 52 RTU-1 450 1.01 SALES AREA#1 SALES RTU-1 1,295 0.12 155 15 19 7.5 146 0.8 376 RTU-2 820 1.02 SALES AREA#2 SALES RTU-2 1,537 0.12 184 15 23 7.5 173 0.8 447 RTU-3 460 1.03 SALES AREA#3 SALES RTU-2 1,251 0.12 150 15 19 7.5 141 0.8 364 1.04 FITTING AREA DRESSING ROOMS RTU-3 522 0.12 63 15 8 7.5 59 0.8 152 1.05 MANAGERS OFFICE OFFICES RTU-3 82 0.06 5 5 2 5.0 10 0.8 19 1.06 STOCKROOM STORAGE ROOM RTU-3 1,834 0.12 220 - - - - 0.8 275 1.07 TOILET #1 TOILET ROOMS - 68 - - - - - - 0.8-1.08 TOILET #2 TOILET ROOMS - 68 - - - - - - 0.8-1.09 JANITORS CLOSET STORAGE ROOM RTU-3 10 0.12 1 - - - - 0.8 2 TOTAL 6,845 TOTAL 1,685 TOTAL 1,730 ELECTRIC UNIT HEATER SCHEDULE HEATING ELECTRICAL MARK MFR MODEL CAPACITY INPUT AMPS VOLT/PH/HZ REMARKS (BTU/HR) KW UH-1 QMARK MUH074 25,600 7.5 9.0 480/3/60 1 REMARKS: 1.) PROVIDE WALL MOUNTED THERMOSTAT AND INTEGRAL DISCONNECT SWITCH. CONTROL DAMPER SCHEDULE UNIT INLET PRIMARY AIR MARK MANUFACTURER MODEL SIZE SIZE MAX MIN REMARKS (CFM) (CFM) CD-1 YOUNG'S REGULATOR 2075-12" 550 140 1,2 REMARKS: 1 FURNISH WITH #T-312-CE THERMOSTAT AND #30-35 TRANSFORMER. 2 PHONE #(440)-232-9700 FOR LOCAL REPRESENTATIVE.

PLUMBING SCHEDULE FIXTURE VALVE/FAUCET CONNECTIONS ELECTRICAL MARK DESCRIPTION MFR MODEL MFR MODEL WASTE VENT CW HW VOLTAGE PHASE REMARKS WATTS WC-1 LAV EWH FCO FD WATER CLOSET AMERICAN CADET - - 4" 2" 3/4" - - - - 1, 10, 11 HANDICAP STANDARD #2467.016, WHITE LAVATORY AMERICAN LUCERNE AMERICAN RELIANT 3 1-1/2" 1-1/2" 1/2" 1/2" - - - 2, 3, 12 STANDARD #0355.012.020 STANDARD #7385.003.002_LH WATER HEATER BOSCH ES4 - - - - 3/4" 3/4" 120 1 1440 4 TANK TRONIC 3000 T 4-GALLON FLOOR CLEAN JAY R. SMITH SERIES 4000 TO - - - - - - - - - 9 OUT SUIT FLOOR FINISH FLOOR DRAIN JAY R. SMITH 2005A-PO5O - - 3" 1-1/2" - - - - - 8 MOP SINK FIAT #MSB-2424 AMERICAN UTILITY 3" 1-1/2" 3/4" 3/4" - - - 5 MS PRODUCTS STANDARD #8354.112.004 ELECTRIC ELKAY EZTL8C - - 1-1/2" 1-1/2" 1/2" - 120 1 325 6 EWC WATER COOLER TWO LEVEL WALL CLEAN JAY R. SMITH 4532S - - - - - - - - - 7 WCO OUT REMARKS: 1 PROVIDE WITH BEMIS MANUFACTURING MODEL 1955SSC STANDARD WHITE OPEN FRONT SEAT LESS COVER. 2 PROVIDE WITH JR SMITH #0700 FLOOR MOUNT LAVATORY CARRIER. 3 PROVIDE WITH TRUEBRO LAV GUARD MODEL #102 FOR TRAP AND SUPPLY PROTECTION. 4 PROVIDE WITH A WATTS PLT-5 2.1 GALLON POTABLE WATER EXPANSION TANK (ET). INSTALL BOTTOM OF HEATER MINIMUM 7'-0" A.F.F.. 5 PROVIDE WITH FIAT PRODUCTS VINYL BUMPERGUARD #E-77-AA. 6 PROVIDE WITH DEARBORN 17GA. TRAP, TRAP ADAPTER AND ANGLE STOP. 7 CAST IRON CLEANOUT TEE WITH STAINLESS STEEL ROUND COVER. PLUG TO BE GAS AND WATER TIGHT. 8 FLOOR DRAIN TO BE PROVIDED WITH TRAP SEAL DEVICE (TS), PROSET TRAP GUARD, SURE SEAL TRAP SEALER OR EQUAL. 9 PROVIDE POLISHED NICKLE BRONZE COVER WITH ZARB-1470-A CLEANOUT PLUG. 10 PRESSURE ASSISTED TANK-TYPE. 11 FURNISH RIGHT HAND AND LEFT HAND MODELS AS REQUIRED PER ADA. 12 PROVIDE WITH MIXING VALVE, AMERICAN STANDARD MODEL #605XTMV1070.