OPERATING INSTRUCTIONS COP-IE, COP-I, COP-E (ANSI 50,51,50N,51N)

Similar documents
OPERATING INSTRUCTIONS COP-F (ANSI 81O/81U)

EARTH LEAKAGE RELAY. User Manual - Issue 1.0

DIGITAL ALARM UNIT Model ALU-AP

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

M15051) INSTRUCTION MANUAL

Operating Manual RCM420

Carbon Monoxide Transmitter

Moulded case circuit brakers

Index Arc Guard Systems. Arc Guard Systems. Arc Guard Systems Industrial Automation Supply - Tel:

Tips how to use the MAS Web tool

CSP-204 CSP-208 CSP-104 CSP-108

La Marche Manufacturing Company Option 46 Series. Digital Combined Accessory Package. Installation and Operation Manual

CTT8 TEMPERATURE MONITOR DEVICE

DPR-145 TEMPERATURE PROTECTION RELAY. DPR-145 User Manual V-2.0 ( ) PT100 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT VDC SUPPLY -1-

CMD420 / CMD421 Series

CommStat 4. Controller for Redundant Telecom HVAC Systems PRODUCT DATA SHEET. Features and Benefits

MTRA-FSP Level Control Relay. Installation & Operation Manual

Analog Room Pressure Monitor RPC Series

ORP (mv) Controller Model: ORP-XP2. UP DOWN ENTER Time & Date Main Menu Alarm Reset

MO n : 12JMC rév A

Smart Temp. Model

UC700 EMERGENCY TRANSFER SYSTEM SPECIFIER S HANDBOOK. 40 Dale Street West Babylon, NY Ph: Fx:

Series Temperature Controller Instruction Sheet

1 Dimensions Installation Mains/boosted cold water inlet Connection to the system Drain Dimension for fixing 6

FCR 05, FCR 07. Power factor correction controller. User and service manual

AC&R Controller RWR Basic Documentation VR2002 for water to water heat pump units

eed quality electronic design USER s MANUAL

Soft Starter Centrifugal Pump Soft Starter Series

03.03.mmm REV.2 09/01

Eswa DC-1. Thermostat for Floor Heating

SAPCON SMART-SSI. Continuous Speed Indicator. Users Manual. . Introduction. . General Description. . Principle of Operation. .

SAS803WHL-7 Thermostat for floor heating

RE-PR3-E-27 3-Phase Panel Mount 27kW

Spa Touch Control Panel with BP2100, BP6013 spa controllers. (Spa Owner s Manual insert)

RSWT. Three phase AC pumps and ventilators soft starter. Benefits. Description

DC VOLTMETER DCV-10 / 10A / 10C / 10S / 10CS / 11 / 11A / 11C / 11S / 11CS. A4741 / Rev.1

Alarm Control Panel WIC-16Z4P WIC-5Z2P. User Instructions

1.7. Insulation fault evaluators EDS460/490 EDS461/491

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

EXPERT TRI-STAR. Temperature controller. User s Manual

Instructions for the fan motor control system with integrated wiring terminals SILVER C

CLEANROOM MONITOR CR3A Network - Installation Instructions

Spa Touch Control Panel with 2000, 2100 controllers. (Spa Owner s Manual insert)

EKC 347 Liquid Level Controller REFRIGERATION AND AIR CONDITIONING. Manual

CommStat 4 Controller

BE1-50/51B with S1 Case or FT-11 sized Case and Cover For non-retrofit applications, see Product Bulletin UHD.

MC200. Users Instructions. HEATING DIVISION Hort Bridge Ilminster, Somerset TA19 9PS Tel: Fax:

1F Non-programmable Electronic Digital Heat Pump Thermostat INSTALLATION AND OPERATION INSTRUCTIONS

DKG-108 POWER FACTOR CONTROLLER

1.7. Insulation fault evaluators EDS460/490 EDS461/491

B-40/B-41 Modulating Temperature Controller

VAMP 120 & 121. Arc flash detection units. Product picture

FPS MANUAL FEEDER PROTECTION SYSTEM

Remote NAC Power Supply D7038

Memcom Emergency Telephone

ISOMETER IR1575. Insulation monitoring device for unearthed AC/3(N)AC systems up to 480 V and DC systems up to 480 V

MST-1. Varifan USER S MANUAL MST-1 ADJUST. 9 per day HI F2. DIFF on off TIMER. reduc.

Emotron DCM Control Unit

Current-Input-Module (CIM) MOTOR PROTECTION UNIT QUICK REFERENCE ESC. December 19, 2006 Revision 0 MAIN MENU. ²Messages Ñ. Metering Ñ.

Room thermostats with LCD for wall mounting

Cat. N. Cat. N (s) 1. DESCRIPTION - USE 3. OVERALL DIMENSIONS. Technology : 4. PREPARATION - CONNECTION 2. PRODUCT RANGE

TEC2100 Series Networked Thermostats

Pakton Technologies Pty Ltd ABN Ferrier Road, Narangba Qld 4504

Operating instructions Safety-monitoring module SRB 302X3. 1 About this document

Product Manual SZ1145

CommStat 6. Controller for Redundant HVAC Systems PRODUCT DATA SHEET

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

1S25. Arc Fault Monitor 4 Zones, 8 Sensors. Features. Introduction. ARC Fault Protection

FPU-32 MANUAL FEEDER PROTECTION UNIT

MYRIAD TRIPLEX PUMP CONTROLLER INSTRUCTION MANUAL

EasyTronic III MANUAL SERVICE

Dryer Controller M720

Passive infrared ceiling sensor

TC515 and TC600 Installation Manual. a Winters company

ISOSCAN EDS460/490 EDS461/491. Insulation fault locators with control and display function for EDS systems (insulation fault location systems)

7SG17-Rho 3 Multifunction Protection Relays Answers for energy

VAMP 120 & 121. Arc Flash Protection Units. Arc Protection. Customer benefits

TEC210x-2 Series Networked Thermostats

Varlogic NRC12. Power factor controller. User manual

User Manual. Dryer Controller M720

MTDPC. (also known as MTPC) INSTALLATION AND OPERATION MANUAL MultiTrode Pump Controller

AQ 100 Series. Arc Flash Protection System

DGC-1000 DIGITAL GENSET CONTROLLER

To operate the 5207 you can use either the built-in touchpad or the Model 5230 Remote Annunciator.

SALES SUPPORT DOCUMENT

Product Manual SZ1144

REMOTE CONTROL FOR CHILLER MYCHILLER

Products and systems

BU: EPBP GPG: DIN Rail Products Devices for the permanent control of insulation on 24 V supply lines for medical locations SELVTESTER-24

EARTH FAULT METER MD-08

How to Map and Test Phase Peak Demand and Load Current Alarms for Single Phase Tripping

Software Version 2.01 LEVEL MONITOR MODEL 220

38-SDMS-03 SPECIFICATIONS FOR LV DIGITAL PANEL METERS

Installation Manual Tracker 221

Tri-Stack Smart System

SENTINEL D - Fault Passage Monitoring

BSR Addressable Fire Detection control panel. Installation operation manual

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

ICS Regent. Fire Detector Input Modules PD-6032 (T3419)

Model A2100 Series Annunciator

Transcription:

OPERATING INSTRUCTIONS COP-IE, COP-I, COP-E (ANSI 50,51,50N,51N) MRM PROCOM Pvt Ltd An ISO-9001-2008 certified organization Works: Plot No. 20-21, Sector 59, Phase II, Faridabad, Haryana -121004 Ph: 0129-4700400 (10 lines)email: pankajgupta@mrmprocom.com, Web: www.mrmprocom.com

Cat_COP-IE,I,E-Ver 1.7-19-11-14 Page 2/10

INDEX 1. Introduction 2. Protection, Supervision Salient features 3. Contacts 4. Front Panel Switch 5. Setting Procedure 6. Parameter Mode 7. External Alarm Contact 8. Set Blocking Function 9. Reset Auto / Manual 10. Terminal Description 11. Model Selection Chart 12. Technical Specification 13. Connection Diagram Cat_COP-IE,I,E-Ver 1.7-19-11-14 Page 3/10

1.0 Introduction 16 Bit RISC, state of art, microcontroller based System. Fundamental measurement of all measured parameters with 1% accuracy of measured value (Not full scale) Backlit LCD Display for easy reading and parameter settings. No need to consult the manual while programming the unit. All system parameters are user programmable All the inputs such as AC voltage and auxiliary voltage are completely isolated Fast Fourier Transformation to extract fundamental components of current and voltage to avoid spurious tripping Housed in 92X92mm Din Standard housing. 2.0 Protection, Supervision Salient Features Three Phase Over current Protection (COP-IE, COP-I) Three Phase Short Circuit Protection (COP-IE, COP-I) Earth Fault Protection (COP-IE, COP-E) High set earth fault protection (COP-IE, COP-E) Display and Measurement Display of R,Y,B Phase Current, Display of neutral / earth current Salient Features Wide range SMPS auxiliary supply (supply range from 50 to 300 VAC/DC Or 8-35 VDC) Digital fast Fourier transformation. Selectable display of current in primary or secondary value Two digital inputs for external reset and external blocking. One common trip contact Three programmable alarm contact Selectable auto / manual scroll of measurement 3.0 Output Contact Four NO contact Contacts are available, one is reserved for tripping function, three are programmable for alarm function. Trip (NO Contact) Alarm 1 (NO Contact) Alarm 2 (NO Contact) Alarm 3 (NO Contact) 4.0 Front Panel Switch COP-IE/I/E has four switch provided on its front panel. Switch can have more than one functions assigned to them. The table below describes the operation of these S.No. Switch Symbol Switch Function Description 1 Next Normal operation mode: In this mode this scrolls the displayed parameters. Programming Mode: It is used to select the next parameter to be programmed. 2 Increment Programming Mode It s used to increment value of the selected parameters. 3 - Decrement Programming Mode It s used to decrement value of the selected parameters. 4 R Reset In manual reset option this Key is used to reset the faults LED and Contact output In it is used to reset the LED indication. 5 R & Programming Mode Entry Press R Key and than press while the R Key is pressed to enter the programming mode. Cat_COP-IE,I,E-Ver 1.7-19-11-14 Page 4/10

5.0 Setting Procedure COP has provision to program the operating parameters. Press R & switch simultaneously. The LCD shall display, Parameter Mode To enter parameter setting mode press. To go to next menu press. The LCD shall display Set Alarm. This menu can be entered by pressing. To go to next menu press. The LCD shall display Set Blocking. This menu can be entered by pressing. 6.0 Parameter Mode Sl..No Display Explanation of parameter Factory setting Setting Range Setting step 1 I > in I/In Desired over current value in % of the 0.80 0.1-2.5 I/In 0.05I/In rated current 2 I > Def Time Definite time delay in seconds, will be 10 Sec 0.01 150 Sec 0.01 Sec valid only when definite time characteristic is selected 3 I > Time Multiplier Inverse time multiplier, will be valid only when Inverse time characteristic is selected 0.3 0.01-1.50 0.01 4 I > Characteristic Time delay characteristic for Over current 5 I > > in I/In Desired short circuit values in % of the rated current. 6 I >> Def Time Definite time delay in seconds, will be valid only when definite time characteristic is selected 7 I e> in I/In Desired Earth fault value in % of the rated current 8 I e> Def Time Definite time delay in seconds, will be valid only when definite time characteristic is selected 9 I e> Time Multiplier Inverse time multiplier, will be valid only when Inverse time characteristic is selected DEFT DEFT, Extreme inverse, Very Inverse, Normal Inverse 0.6, Normal inverse 1.3, Normal Inverse 3.0 2.0 0.5-12.0 I/In 0.1 I/In 2.0 0.03 20 Sec 0.01 Sec 0.20 0.05-2.5 I/In 0.05I/In 10 Sec 0.03 150 Sec 0.01 Sec 0.3 0.01-1.50 0.01 Cat_COP-IE,I,E-Ver 1.7-19-11-14 Page 5/10

10 I e> Characteristic Time delay characteristic for Earth fault current 11 I e> > in I/In Desired earth fault high set value in % of the rated current 12 I e>> Def Time Time delay setting for earth fault high set 13 CT Ratio Ratio of current transformer, Rated CT Primary current / Rated CT Secondary current DEFT DEFT, Extreme Inverse, Very Inverse, Normal Inverse 0.6, Normal inverse 1.3, Normal Inverse 3.0 1.0 0.3-4.0 I/In 0.1 I/In 0.6 0.02 20 Sec 0.01 Sec 100 1-2500 1 14 Reset Delay Delay time for resetting the trip 1 0.1-20 Sec 0.1 Sec. contact, after fault clearance. 15 Dis I in Pri/Sec Selection of Current display in primary values or secondary values Primary Primary/Secondar y 16 Disp Auto Scroll Measurement display auto scroll or manual scroll selection Auto Scroll On Auto Scroll On / Auto Scroll off 17 Trip Reset Reset type for tripped LED indication Manual Auto / Manual 7.0 External Alarm Contact Alarm Contact 1,2 & 3 can be programmed / activated on different protection functions e.g. for activating alarm 1 on over current, set 1. By default no alarm is active. If the alarms are required, they have to be programmed at the time of installing the relay. The protections on which alarms can be programmed are: Protection Function Protection Symbol Activated Alarm, Remark default setting Over Current I > 0 No Alarm activated on I > Short Circuit I >> 0 No Alarm activated on I >> Earth Fault Low set Ie > 0 No Alarm activated on Ie > Earth Fault High set Ie >> 0 No Alarm activated on Ie >> 8.0 Set Blocking Function Group of Selected protection function can be disabled on activation of blocking input (By externally shorting terminal 7 and 8)e.g. If. I >> and I >> are programmed as enabled for blocking input then on shorting terminal 7 and 8 and High set over and under voltage protection will be blocked/disable. Protection Function Protection Blocking enable/ Remark Symbol Disable default setting Over Current I > Disable Blocking function is disable Short Circuit I >> Disable Blocking function is disable Earth Fault Low set Ie > Disable Blocking function is disable Earth Fault High set Ie >> Disable Blocking function is disable Cat_COP-IE,I,E-Ver 1.7-19-11-14 Page 6/10

9.0 Reset Auto / Manual User can programme COP-I either as auto reset or manual reset relay. Auto Reset : The trip contact will reset automatically after Reset Delay, Indication will reset automatically after clearance of fault and expiry of reset delay. Manual Reset : The trip contact will reset automatically after Reset Delay, Indication will reset after pressing the reset button. 10.0 Terminal Description Terminal Number Description 1 Not Connected 2 Not Connected 3 Not Connected 4 Not Connected 5 CT Earth Current 6 CT Earth Current 7 Common for external reset and blocking 8 External Block 9 External Reset 10 Auxiliary Supply 11 Auxiliary Supply 12 Not Connected 13 Trip NO Contact 14 Trip NO Contact 15 Alarm 1 NO 16 Alarm 2 NO 17 Alarm 3 NO 18 Common terminal for Alarm 1,2 & 3. 19,20 R Phase CT 21,22 Y Phase CT 23,24 B Phase CT 11.0 Model Selection Chart Type Protection Rated Current Auxilliary Voltage COP IE : Overcurrent, short circuit, Earth Fault & 1 : Secondary 1A L: 8-35 VDC high set in earth fault 5 : Secondary 5A H: 50-300 VAC/DC I : Overcurrent & Sort circuit E : Earth fault & high set in earth fault 12.0 Technical specification AC voltage withstand 330 VAC, Continuously, (Phase to neutral) Frequency Range 40-70 Hz Rated Current 1A /5A Current withstand 4 times rated current Measurement Accuracy Voltage & Current ± 2% Frequency ± 0. 05 Hz. Surge 1.2/50Usec 2.5KV Auxiliary Voltage 8-35V/DC OR 50-300 V AC/DC Contact Rating 230 VAC, 5A Cut out Dimensions 90mm X 90mm Depth 120mm Cat_COP-IE,I,E-Ver 1.7-19-11-14 Page 7/10

13.0 Connection Diagram COP-IE- 3 Phase Over curent, short circuit and earth fault protection Cat_COP-IE,I,E-Ver 1.7-19-11-14 Page 8/10

COP-I Over-Curent and Short Circuit Protection COP-E Earth Fault Protection Cat_COP-IE,I,E-Ver 1.7-19-11-14 Page 9/10

It is our endeavour to constantly upgrade our products, hence specifications are subject to change without any notice. Cat_COP-IE,I,E-Ver 1.7-19-11-14 Page 10/10