FIRE/SMOKE BARRIER FUNDAMENTALS

Similar documents
3/6/2018. Design Tips For Fire and Smoke Barriers. Professional Development Hours (PDH) Certificates. Copyright Materials

NFPA 45 NFPA 211 NFPA 1600

LABELING OF FIRE-RATED GLAZING STUDY GROUP REPORT TO CTC MEETING CHICAGO, IL - OCTOBER 13-14, 2011 CODE CHANGES

2012 International Fire Code Significant Changes. IFC Background. Purpose IBC and 2012 NFPA 101 Significant Means of Egress Changes

ICC CODE TECHNOLOGY COMMITTEE Area of Study Labeling of Fire Rated Glazing

BUILDING CODE OF THE CITY OF NEW YORK. New York City Department of Buildings 4 June 2007

Presented by: Bill Lauzon, PE Lauzon Life Safety Consulting, LLC Web: Lauzon-LSC.com

Defend In Place 2012 IFC Overview of Institutional Occupancies

Objectives. To review updated IBC and fire test requirements when designing for life safety.

JOINT COMMISSION PREPAREDNESS / STATEMENT OF CONDITIONS DRAWINGS WSSHE SOUTHWEST CHAPTER NOVEMBER 19, 2015

Building Codes & Standards for Healthcare. Healthcare Construction Certificate - Level 1

Code Technologies Committee Report Elevator Lobby Group A changes: Elevator Lobby

THE 2012 EDITION OF THE LIFE SAFETY CODE HOSPITAL EDITION SESSION #6

COMPLIANCE ALTERNATIVES

PERFORMANCE COMPLIANCE METHODS

NFPA 101, 2012 EDITION IMPACT ON NEW AND EXISTING HEALTH CARE FACILITIES

FIRE-RESISTANCE-RATED CONSTRUCTION A Primer on IBC Chapter 7

COMPLIANCE ALTERNATIVES

For the Florida Building Commission And the Fire Code Advisory Council

Barrier Management Symposium An Executive Summary

PERFORMANCE COMPLIANCE METHODS

1 of 4 10/26/2015 1:58 PM. Committee Input No NFPA [ Section No ]

Building & Fire Code Academy. Building Better With Our Greatest Resource Education. Welcome!

Code Technologies Committee Report Fire Rated Glazing Group A changes: Fire rated glazing

Taming the Health Care Building Codes NFPA vs. The International and Chicago Building Codes JENSEN & HALSTEAD LTD.

DUCT SYSTEMS CHAPTER 6

Public. Mike Free Health. State of Alabama Department of

F, T, L and W Ratings - What are the Code & Testing Requirements?

2018 NICET Code Transition Changes

Public Health Fax: Web Site:

Fire and Life Safety Committee

The Residences at Christina Landing Wilmington, DE

Common Building Code Misinterpretations

2018 International Fire Code. Add new text as follows:

PERFORMANCE COMPLIANCE METHODS

FIRE SAFETY UPGRADING CONSIDERATIONS for EXISTING SENIOR CITIZEN LODGES

AD HOC HEALTHCARE COMMITTEE MEANS OF EGRESS WORK GROUP APPROVED CODE CHANGE DRAFTS CODE GROUP B MOE COMMITTEE

Agency for Health Care Administration

January 1, 2014 Mandatory Effective Date

AHC Meeting #7 July 12-13, Occupancy WG Report

The Physical Environment Portal: Module 5, LS Leadership

CODE TECHNOLOGIES COMMITTEE NURSING CARE FACILITIES WORK GROUP APPROVED CODE CHANGE DRAFTS CODE GROUP B

Balloting Version First Draft NFPA 101 Life Safety Code Proposed 2015 Edition

Preview of the MA Building Code (780 CMR) 9 th edition

Date: February 22, 2005 Kimbalton DUSEL, Pre-S-2 Submittal CNA0402 PRELIMINARY CODE REVIEW. International Plumbing Code Edition

Fire Rated Door Assemblies: Compliant Designs

Agency for Health Care Administration

REPORT HOLDER: SMOKE GUARD, INC. 287 NORTH MAPLE GROVE ROAD BOISE, IDAHO EVALUATION SUBJECT:

Following are code change proposals submitted through Adhoc Health from General study group and related changes. General. Position.

PROPOSED Houston Amendments to the 2015 International Building Code

2012 International Building Code Errata (Portions of text and tables not shown are unaffected by the errata)

IBC Committee Responsibility Matrix January 2017

2012 B.C. Building Code Compliance Review (Division B Part 3)

DUCT SYSTEMS CHAPTER 6

FIRE PROTECTION KEY DESIGN CONCEPTS IN HEALTHCARE FACILITIES Scott Twele, Aman Shah Steven Dannaway. AIA Healthcare Group

Agency for Health Care Administration

Chapter Nursing Homes

THE 2012 EDITION OF THE LIFE SAFETY CODE NURSING HOME EDITION SESSION #4

DUCT SYSTEMS CHAPTER 6

Building Description Applicable Codes & Standards Prescriptive Requirements. Performance Based Design

Questions related to specific materials, methods, and services will be addressed at the conclusion of the presentation.

Agency for Health Care Administration

Are there any policies regarding outlets that contain USB ports?

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT NO 68 (ENGLISH AND PHILOSOPHY)

MECKLENBURG COUNTY FIRE MARSHAL S OFFICE

SECTION ELEVATOR FIRE RATED SMOKE CONTAINMENT SYSTEM

SPECIAL DETAILED REQUIREMENTS BASED ON USE AND OCCUPANCY

WORKSHEET 2-1 THE MANITOBA RESIDENTIAL OCCUPANCY FIRE RISK INDEX FIRE SAFETY PARAMETER VALUES

NFPA 101 Code Update from 2012 Edition to the 2015 Edition

Nevada State Board of Architecture, Interior Design & Residential Design May 1, 2013

NFPA 101 and NFPA 99, 2012 Editions Code Update. where art meets engineering

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST FIRE ALARM SYSTEM INSTALLATION

Open to Below: A Discussion of Allowed Floor Openings. Jay A. Ierardi, Ph.D., P.E., LEED AP. Kevin S. Hastings, P.E., LEED AP

Agency for Health Care Administration

PROPOSED CODE CHANGES FOR REVIEW BY THE FIRE CODE ACTION COMMITTEE

The one-half hour seminar in module 2 that follows, will complete the remainder of chapter 3, building planning, already begun in module 1.

Changes to NFPA 101A 2013 Edition for Health Care Facilities

2. The Group F occupancy has have an a combined occupant load of 500 or more above or below the lowest level of exit discharge.

CHAPTER 7 ALTERATIONS LEVEL

Module 7. Control of Smoke & Highlights of Code Requirements

ROP MEETING MINUTES. 2. Introduction of Attendees. The following committee members and guests were in attendance. TECHNICAL COMMITTEE MEMBERS PRESENT

Moreno Valley Fire Department Fire Prevention Bureau. New and Existing Fire Alarm & Signaling Systems Guideline

DEALING WITH FIRE SAFETY

SPRINKLER PROTECTION OF COMBUSTIBLE CONCEALLED SPACES WITH LESS THAN 6 BETWEEN OPPOSITE FACES IN CAVITY.

Report on First Revisions with Statement June 2014 NFPA 101

2007 CBC & CFC Residential Care Facility Requirements (24 hour care only)

First Aspen Federal Regulation Set: K LSC 2000 Health Existing

Agency for Health Care Administration

C. None (No sprinkler system) K3 E. NUMBER OF BEDS CERTIFIED FOR MEDICAID

SCHULTE & ASSOCIATES Building Code Consultants 880D Forest Avenue Evanston, IL fpeschulte.

Recommended Amendments to the 2015 International Existing Building Code North Central Texas Council of Governments Region

Fire Safety Evaluation of Existing Manufactured Educational Building Covered by Section 423 of the Florida Building Code

CTC Meeting #27 JUNE 17 18, 2013 NIST report on the Charleston sofa store fire

BCAC Egress Work Group

1) Height Limit: About seven stories

BCBC 2012 CHANGES TO PART 3

Report to Adhoc Health Code change proposal regarding locking arrangements From John Woestman, BMHA

Life Safety Crosswalk

FIRE INSPECTORS GUIDELINES FOR PLAN REVIEWS AND INSPECTIONS OF NEW CONSTRUCTION / ADDITIONS AND CHANGE OF OCCUPANCY

Life Safety Damper Installation ASHRAE St Louis Chapter Feb. 9,2015. Peter McDonnell, PE, LEED AP BD+C McClure Engineering

Transcription:

FIRE/SMOKE BARRIER FUNDAMENTALS William E. Koffel, P.E., FSFPE President Koffel Associates, Inc. www.koffel.com wkoffel@koffel.com Expertly Engineering Safety From Fire

OBJECTIVE Identify the different types of barriers used in buildings on higher education campuses Identify the key characteristics for each barrier Continuity Protection of openings List at least three strategies that can be used to improve a barrier management program

TYPES OF WALL ASSEMBLIES Exterior walls Fire walls Fire barriers Fire partitions No such assembly in NFPA Smoke barriers Smoke partitions

FIRE TESTED WALL ASSEMBLIES In accordance with ASTM E119/UL263 Resist passage of heat and hot gases Structural integrity during the test fire Have something left at the end of the test

FIVE POINTS Required fire-resistance rating Continuity Openings and penetrations Types of materials Structural robustness

FIRE BARRIERS Fire barriers are used in the following applications: Fire area separations Mixed occupancy separations Incidental use areas Hazardous area separations Exit enclosures Shaft enclosures Horizontal exits Corridor walls NFPA only

CONTINUITY 33

SUPPORT Supported by construction with the same fireresistance rating as the fire barrier Some exceptions Vary between NFPA and ICC

SUMMARY OF FIRE BARRIERS Issue Required Fire-Resistance Rating Required continuity Openings Types of materials Robustness of structural system Requirement Depends upon specific use Floor/ceiling below to deck above General: Aggregate glazing area (or width) <25% wall area/length; maximum size 120 sf. Specific: Rules based on use of barrier As required for the type of construction If load bearing, fire tested with load

FIRE PARTITIONS Fire partitions are used in the following applications: Dwelling units separations Sleeping units in Group R-1, R-2 and I-1 Tenant separation in covered malls Exit access corridor walls Elevator lobby separation Remember, NFPA does not use this phrase

SUMMARY OF FIRE PARTITIONS Issue Required Fire-Resistance Rating Required continuity Openings Types of materials Robustness of structural system Requirement 1 hour, with exceptions, depending on use. For corridors see Table in Chapter 10 IBC only Floor/ceiling below to deck above or tight to underside of fire-resistance rated assembly. Supported by fireresistance rated construction, except in corridors, tenant, and guestroom separations in Types IIIB and VB construction 20 minutes (w/o hose stream) for corridors 45 minutes for all others As required for the type of construction If load bearing, fire tested with load

SMOKE BARRIERS Smoke barriers are used in the following applications: Group I-2 Group I-3 Areas or refuge Other specific applications

SUMMARY OF SMOKE BARRIERS Issue Required Fire-Resistance Rating Required continuity Openings Types of materials Robustness of structural system Requirement 1-hour with the exception that a construction of a minimum 0.1 thick steel in Group I-3 buildings is allowed Horizontal: Vertical: Outside wall to outside wall Floor to slab or deck above, continuous through interstitial spaces Supporting construction may be required based upon the applicable codes 20 minutes but not a true fire door in NFPA 101 Smoke- and draft-controlled doors tested in accordance with UL 1784 IBC only As required for the type of construction If load bearing, fire tested with load

SMOKE PARTITIONS Smoke partitions are used in the following applications: Corridor walls in Group I-2 IBC only Sprinkler protected hazardous areas NFPA

SUMMARY OF SMOKE PARTITIONS Issue Required Fire-Resistance Rating Required continuity Openings Types of materials Requirements Not required (unless otherwise required) Floor/ceiling below to deck above or tight to underside of ceiling membrane in ceiling membrane designed to limit passage of smoke - Difference between NFPA/ICC for ceiling tiles Windows: Sealed to resist free passage of smoke Doors: No louvers Air leakage rated (UL 1784) IBC??? Self closing, or automatic closing by smoke detectors As required for the type of construction Robustness of structural system If load bearing, fire tested with load.

LS DRAWING INFORMATION

LS DRAWING INFORMATION A legend that clearly identifies features of fire safety Areas of the building that are fully sprinklered (if the building is partially sprinklered) Locations of all hazardous storage areas Locations of all rated barriers Locations of all smoke barriers Suite boundaries, including the size of the identified suites both sleeping (max 10,000 sq ft) and non-sleeping (max 10,000 sq ft) Locations of designated smoke compartments Locations of chutes and shafts Any approved equivalencies or waivers

SUCCESSFUL STRATEGIES BUILD IT CORRECTLY Thorough plan review process Contractor qualifications Commissioning systems and buildings o NFPA 3, NFPA 4, ASHE documents o Complete code compliance documentation while contractor still on site Use of certified inspectors or special inspectors

BUILD IT CORRECTLY!!

SUCCESSFUL STRATEGIES Make sure all rehabilitation work is done correctly Refer to previous slides Above ceiling work permits Means to identify approved individuals Proper identification Labels Marking Life Safety Drawings

ADDITIONAL RESOURCES Visit www.koffel.com for links to a LinkedIn Life Safety Code Discussion Group NFPA www.nfpa.org/### ASHE

QUESTIONS AND DISCUSSION Expertly Engineering Safety From Fire