MiNI SWIMMING POOL HEAT PUMP UNIT. Installation & Instruction Manual

Similar documents
SWIMMING POOL HEAT PUMP UNIT Installation & Instruction Manual Duratech - series

Harmo Powerpack Horizontal Units Installation & instruction manual

SWIMMING POOL HEAT PUMP UNIT Installation & Instruction Manual

SWIMMING POOL HEAT PUMP UNIT. Installation & Instruction Manual

SWIMMING POOL HEAT PUMP UNIT. Installation & Instruction Manual

SWIMMING POOL HEAT PUMP UNIT POMPA DI CALORE PER PISCINA

SWIMMING POOL HEAT PUMP UNIT POMPA DI CALORE PER PISCINA. Installation & Instruction Manual - p. 1 Manuale di Installazione e d'uso p.

SWIMMING POOL HEAT PUMP UNIT ECO - series. Installation & Instruction manual

SWIMMING POOL HEAT PUMP UNIT. Installation & Instruction Manual

SWIMMING POOL HEAT PUMP UNIT. Installation & Instruction Manual

Instruction manual Harmo PAC ZVWX1017/1022/1032/1041/1055/1056/1061

SWIMMING POOL HEAT PUMP UNIT

Swimming Pool Heat pump Instruction manual Harmo PAC series (Type ZVWX1017, ZVWX1023, ZVWX1033, ZVWX1042, ZVWX1052, ZVWX1057, ZVWX1062)

THERMOTEC INVERTER SWIMMING POOL HEAT PUMP

SWIMMING POOL HEAT PUMP UNIT. Installation & Instruction Manual

OWNER S MANUAL. Vintage Classic HEAT COOL models. Proudly Made in the USA

WATER COOLED WATER HEAT PUMP. Installation & Instruction Manual

OWNER S MANUAL. Models: AC110, AC125, AC150 made from 2003 through Proudly Made in the USA

Astral Pool Residential Heat Pump

Pool & Spa The Duratech Heat Pumps

Pool & Spa The Duratech Heat Pumps

OWNER S MANUAL. Vintage Signature Series models: AC750, AC1050, AC1100, AC1250, AC1500, AC1750. Proudly Made in the USA.

Owner s Manual PRINTED IN CANADA 05/2009

SWIMMING POOL HEAT PUMP

OWNER S Manual PRINTED IN CANADA 10/2009

OWNER and INSTALLATION MANUAL

INSTALLATION AND USER MANUAL

Installation Manual Compac 6/8

INSTALLATION AND USER MANUAL

G&F Manufacturing Swimming Pool Heat Pump Install & Operations Manual

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

This manual should be maintained in legible condition and kept adjacent to the heat pump or in a safe place for future use.

Owner s Manual for Swimming Pool Heat Pump

SWIMMING POOL HEAT PUMP UNIT

Air Source Water Chiller and Heat Pump

Warning: 230V / 1ph / 50Hz V / 3ph / 50Hz. Remarks: Make sure that you have enough power. (See page 15 Cable table)

HP50HA ABG Heat Pump

Installation and Instruction Manual

MACH N-407 Heat Pump Air-Cooled Chiller

SWIMMING POOL HEAT PUMP UNITS. Installation & Instruction Manual EU - series

Swedish design and manufacture since 1967

INSTALLATION AND USER MANUAL

Swimming Pool Heat Pump

Hydro-S Heat pump 230V black type 12horizontal. Swimming Pool HeatPump UserandServicemanual

SWIMMING POOL HEAT PUMP Owners Manual

INSTALLATION AND USER MANUAL

INSTALLATION, OPERATION AND MAINTENANCE

Contents. Specifications. Description SV HP 55 SV HP 90. Specifications Warnings Introduction Overview... 4

SWIMMING POOL & SPA HEAT PUMPS OWNERS OPERATIONAL MANUAL

ASTRALPOOL HEAT PUMP CATALOGUE

FORCE SERIES SWIMMING POOL HEAT PUMP INSTALLATION AND OPERATION MANUAL PLEASE READ THIS MANUAL CAREFULLY BEFORE INSTALLING OR OPERATING THE UNIT

Index. Index. Heatseeker Nova Inverter Heat Pump. Heatseeker Nova Inverter Heat Pump. supremeheating.com.au

CHILLER. Model CH3000. Operator s & Installation Manual

Check that connection to main board is clean and sound at J8

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

OPERATION AND MAINTENANCE MANUAL ELC-810 AUTOMATIC WATER LEVEL CONTROLLER. AquatiControl Technology

Call us today! (800)

MAC N-407 Air-Cooled Chiller

G&F Manufacturing Service Manual Version 2.0 April 2010

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

MAC-120HE-03 Air-Cooled Chiller

Owner s Manual & Installation Guide. Model 525S Model 525TI Model 650TI Model 650SC Model 700TI

INSTALLATION MANUAL. G&F Manufacturing 7902 Interstate Court North Fort Myers, Florida

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

C&H NORDIC Commercial 4 SERVICE MANUAL

HT V2 HT Split

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

TECHNICAL, OPERATING & INSTALLATION MANUAL TC 15, 33, 52 AIR COOLED PACKAGED WATER CHILLERS

SECTION PACKAGED COMPRESSOR AND CONDENSER UNITS

Product Data. Features/Benefits. OMNIZONE 50BRN,BZN Water-Cooled and Remote Air-Cooled Indoor Self-Contained Systems. 5 to 20 Nominal Tons

Installation and operating instructions. Temperature difference controller 6 inputs, 3 outputs, integrated data logger for SD card

DynaPack. Vertical Packaged Air Conditioner Featuring Gas Heat/Electric Cooling Designed to Serve Multi-Family Applications

SECTION SPLIT-SYSTEM AIR-CONDITIONERS

USER S MANUAL HSC-14/18/24/24A

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh AIR CONDITIONERS 13ACXN PRODUCT SPECIFICATIONS

Quick Start Guide. For product manuals and further installation / operation procedures visit

OACS Outdoor Air-Cooled Central Chillers

OPERATING MANUAL AIR CONDITIONER DUCT TYPE. ART Series KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N

SPA HEATER INSTALLATION, OPERATION AND MAINTENANCE

MODULAR AUTOMATIC GRANULAR ICE FLAKER

Inverter Swimming Pool Heat Pump

CONTENTS SAFETY PRECAUTIONS. En-1 DANGER! CAUTION!

1. Information before installation General terms of delivery, storage and transport

Liebert CSU3000 Chiller

User Operation Manual

R410A. AIR CONDITIONER DUCT TYPE / ART Series OPERATING MANUAL. REFRIGERANT This Air Conditioner contains and operates with refrigerant R410A.

Hi - Wall Split Systems 12K - 18K - 24K

SERVICE MANUAL UNI SPLIT SERIES. ASC-xxBI, ASD-xxBI, ASF-xxBI, ASGE-xxBI, ASGE-xxBI-3

T-Series Air Conditioner T15 Model

Freeze Protection Thermostat TRACON MODEL GPT 3 Installation and Operation Manual

ECO RANGE INVERTER HEAT PUMPS

Call us today! (800)

FOR THE RECORD. You should record the model and serial numbers, which can be found on the back of the unit, for future reference.

.2 Section Waste Management and Disposal.

40KMC KMQ

CH250 AND CH251 CHILLERS

Swimming Pool Heat Pump

User s Information and Installation Instructions

FLOOR CONSOLE/ UNDER CEILING DUAL TYPE. ABT Series FUJITSU GENERAL LIMITED AIR CONDITIONER OPERATING MANUAL P/N

Transcription:

MiNI SWIMMING POOL HEAT PUMP UNIT Installation & Instruction Manual

5.Maintenance and inspection 5.1 Maintenance To check the water supply device and the releaser often. You should avoid the condition of no water or air enter into system, or that will influence unit's performance and reliability. You should clear the water filter regularly to avoid unit's damage by filter's jam. There should be dry, sanitary and ventilation around the units. To clean the side heating exchanger regularly for keeping good heating exchanging and saving energy. To check the operation of every process in the u nit, the operation pressure of the refrigerant system. You should maintain or change it in time. To check the power supply and cable connection often, there is abnormal action or bad smell about the electrical component. If there is, please maintain or change it in time. Please discharge all water in the water pump and water system lest freeze the water pump or water system. You should discharge the water at the bottom of water pump if the units will stop for long time. And you should check the units thoroughly and fill the system with water fully before power on the units again. 5.2 Ordinary malfunctions and solution malfunction Pilot lamp Reason resolution contents 1.PREFACE 2.SPECIFICATION 2.1 PERFORMANCE DATA OF SWIMMING POOL HEAT PUMP UNIT 2.2THE DIMENSION FOR SWIMMING POOL HEAT PUMP UNIT 3. INSTALLATION AND CONNECTION 3.1 INSTALLATION OF SYSTEM 3.2 SWIMMING POOL HEAT PUMPS LOCATION 3.3 HOW CLOSE TO YOUR POOL? 3.4 SWIMMING POOL HEAT PUMPS PLUMBING Normal working on 3.5 SWIMMING POOL HEAT PUMPS ELECTRICAL WIRING Evaporator sensor failure Evaporator sensor failure Flow switch failure Power supply connections wrong High pressure Low pressure E1 1 flash 2 flash 3 flash 4 flash 5 flash Thermostat probe fault. The sensor is open or short circuit No water/little water in water system. Wrong connections or lack of connection High pressure switch action Low pressure switch action Check or change the sensor Check or change the sensor Check the water flow volume, water pump is failure or not Check connections of power cable Check through each pressure switch and return circuit Check through each pressure switch and return circuit 3.6 INITIAL STARTUP OF THE UNIT 3.7 WIRING DIAGRAM 4.USAGE 4.1 FUNCTIONS OF TEMP.CONTROLLER. 5.MAINTENANCE AND INSPECTION 5.1 MAINTENANCE 5.2 ORDINARY MALFUNCTION AND SOLUTION 11

1. Preface 4.Usage 4.1 Functions of temp.controller. In order to provide our customer with high quality, high reliability and excellent flexibility, The produces have been produced by strict producing standard. This manual includes all necessary information about installation, debugging, discharging and maintenance. Please read this manual carefully before you open or maintain the unit. The unit must be installed by professional personnel. The Warranty must be in line with following terms: The company will be not in charge of someone injured or unit wrecked that caused by improper installation, debugging, unnecessary maintenance and do not obey the manual. The unit just can be opened by our maintenance centre personnel or our authorized company. The operation and maintenance must be executed strictly according to the stated time and frequency. Use our spare parts only. The repair will be out of validity automatically if disobeying any terms that listed as above. Swimming Pool Heat Pump Unit, which can heat the swimming pool water and keep the temperature steady. Indoor unit can adopt hidden (semi-hidden) type to assort with elegant and luxury house, so, it has been used widely. This type has following characteristics: 1 Durable The heating exchanger is made of PVC& titanium tube which can against the chlorine or such erodent. 2 Flexible installation You can choose that install the water unit outdoor or indoor. 3 Quiet operation Unit was made of high efficient rotary/ scroll compressor and low noise fan motor, which guarantee units' quiet operation. 4 Advanced controlling Micro-computer controlling, all operation parameter can be set, and all operation status can display on the wire controller,you can also choose remote controlling. 5 Large working scale The ambient temperature is as low as -10 under heating mode. Up key: Scrolls through the menu items Increases the values. Down key: Scrolls through the menu items Decreases the values. Fnc key: ESC function(exit). Set key: Accesses the setpoint. Accesses the menus. Confirms the commands. MACHINE STATUS MENU To access the Machine Status menu Press and quickly release the set key. If alarms are not present, the label Set appears. By using the Up and Down keys you can scroll through the other folders in the menu: -Pb1:probe 1 value folder; -Set:setpoint setting folder. ATTENTION: If the temperature value be set to T degree, the stop point of the unit will be T-2 degree and restart point will be T+2 degree. 1 10

3. Installation And Connection 3.7 Wiring diagram SWIMMING POOL HEAT PUMPWIRING DIAGRAM CONTROLLER 1 2 3 6 7 8 9 t` AC-N t` T1 ALARM Sw1 OFAN Sw2 Sw3 4WV Sw4 FLOW SW. COMP ALARM LAMP RK Sw5 AC-L Sw6 PASRW010 K C S R C1 L N TO POWER SUPPLY 220VAC/50Hz Y/G 2.Specification 2.1Performance data of Swimming Pool Heat Pump Unit for mono-bloc type UNIT Model Heating Capacity kw BTU/h Heating Power Input kw Running Current(Cooling/Heating) A Power Supply V/Ph/Hz Compressor Quantity Compressor Fan Quantity Fan Power Input W Fan Rotate Speed RPM Fan Direction Noise db(a) Water Connection mm Water Flow Volume 3 m /h Water Pressure Drop(max) kpa Unit Net Dimensions(L/W/H) mm Unit Shipping Dimensions(L/W/H) mm Net Weight/ Shipping Weight kg PASRW010 3.0 13500 0.8 3.6 220-240/1/50 1 Rotary 1 30 850 horizontal 50 32 1.5 10 760/320/540 890/345/590 28/31 Measurement conditions: Heating Outdoor air temp: 24 /19,Inlet water temp:27 9 2

2. Specification 2.2The dimension for Swimming Pool Heat Pump Unit- Monobloc Unit Model:PASRW010 498 285 320 760 Vertical vision 3. Installation And Connection 3.6 Initial startup of the Unit NOTE- In order for the unit to heat the pool or spa, the filter pump must be running to circulate water through the heat exchanger. Start up Procedure - After installation is completed, you should follow these steps: 1. Turn on your filter pump. Check for water leaks and verify flow to and from the pool. 2. Turn on the electrical power supply to the unit, then press the key ON/OFF of wire controller, It should start in several seconds. 3. After running a few minutes make sure the air leaving the top(side) of the unit is cooler (Between 5-10 degrees F) 4. With the unit operating turn the filter pump off. The unit should also turn off automatically, If not, readjustment of flow switch is required. 5. Allow the unit and pool pump to run 24 hours per day until desired pool water temperature is reached. When the water-in temp. Reach setting, The unit just shuts off. Unit will now automatically restart (as long as your pool pump is running) when the pool temperature drops more than 2 centigrade below set temperature. 539 Horizontal vision Water Flow Switch - the unit is equipped with a flow switch that turns it on when the pool pump is running and shuts it off when the pump shuts off. This switch is the same type used in all gas pool heaters and is factory adjusted for normal pool installations. If the pool water level is more than a few feet above or below the thermostat knob of the unit, your dealer may need to adjust it at initial startup. Time Delay- The unit is equipped with a 3 minute built-in solid state restart delay included to protect control circuit components and to eliminate restart cycling and contactor chatter. This time delay will automatically restart the unit approximately 3 minutes after each control circuit interruption. Even a brief power interruption will activate the solid state 3 minute restart delay and prevent the unit from starting until the 5 minute countdown is completed. Power interruptions during the delay period will have no effect on the 3 minute countdown. 3 8

3. Installation And Connection 3.5 Swimming Pool Heat Pumps Electrical Wiring NOTE: Although The unit heat exchanger is electrically isolated from the rest of the unit, it simply prevents the flow of electricity to or from the pool water. Grounding the unit is still required to protect you against short circuits inside the unit. Bonding is also required The unit has a separate molded -in junction box with a standard electrical conduit nipple already in place. Just remove four screws and the front panel, feed your supply lines in through the conduit nipple and wire-nut the electric supply wires to the three connections already in the junction box. (four connections if three phase) To complete electrical hookup connect Heat pump by electrical conduit, UF cable or other suitable means of the proper size wire (as permitted by local electrical codes) to a dedicated AC power supply branch circuit equipped with the proper circuit breaker, disconnect or time delay fuse protection. Disconnect - A disconnect means (circuit breaker, fused or unfused switch) should be located within sight of and readily accessible from the uni, This is common practice on commercial and residential air conditioners and heat pumps. It prevents remotely energizing unattended equipment and permits turning off power at the unit while the unit is being serviced. 3. Installation And Connection 3.1 Installation of system Installation Heat Pump & Chlorinator Pressure-type Chlorinator or Brominator Check-valve Filter P-trap Check-valve In-line Chlorinator or Brominator Chlorinator Water Pump Pool Filter Water Pump P-trap P-trap Check-valve Chlorinator Pool A bypass is recommended for most installtions.with the bypass only a part of the water flow will pass through the heat exchanger. 7 4

3. Installation And Connection 3.2 Swimming Pool Heat Pumps Location The unit will perform well in any outdoor location provided three (3) things are present - 1. Fresh Air - 2. Electricity - 3. Pool filter piping The unit may be installed virtually anywhere outdoors. For Indoor Pools Consult the Factory. Unlike a gas heater it has no draft or pilot light problem in a windy area. DO NOT place the unit in an enclosed area with a limited air volume where the unit discharge air will be recirculated. or close to shrubs which can block air inlet These locations rob the unit of a continuous source of fresh air which reduces it efficiency and may prevent adequate heat delivery. 3. Installation And Connection 3.4 Swimming Pool Heat Pumps Plumbing The Swimming Pool Heat Pumps exclusive full flow titanium heat exchanger requires no special plumbing arrangements or bypass. The water pressure drop is less than 10kPa at max. Flow rate. Since there is no residual heat or flame temperatures, The unit does not need copper heat sink piping. PVC pipe can be run straight into the unit. Location: Connect the unit in the pool pump discharge (return) line downstream of all filter and pool pumps, and upstream of any chlorinators, ozonators or chemical pumps. Standard model have slip glue fittings which accept 1.5" (1")Schedule 40(25) PVC pipe for connection to the pool or spa filtration piping. By using a 2"(1.5") schedule 40 (25)sleeve or coupler you can plumb 2"(1.5") straight into the unit. Give serious consideration to adding quick coupler fitting at the unit inlet and outlet to allow easy draining of unit for winterizing and to provide easier access should servicing be required. Air inlet CONTROLLER FROM PUMP (inlet) TO POOL (outlet) AIR DISCHARGE Air outlet CONDENSER DRAIN FIELD POWER SUPPLY CONN EXCHANGER DRAIN 3.3 How Close To Your Pool? Normally, the pool heat pump are installed close together and within 25 feet of the pool. The longer the distance from the pool, the more heat loss from the piping. Since most of the time the piping is buried, the heat loss is minimal for runs of up to 50 feet (50 feet to and from the pump = 100 feet total) unless the ground is wet or the water table is high. A very rough estimate of heat loss per 100 foot is 2500 BTU/hr for every 10 F difference in temperature between the pool water and ground surrounding the pipe, which translates to about 3% to 5% increase in run time. Condensation: Since the Heat pump cools down the air about 6-10 F, water may condense on the fins of the horseshoe shaped evaporator. If the relative humidity is very high, this could be as much as several gallons an hour. The water will run down the fins into the basepan and drain out through the barbed plastic condensation drain fitting on the side of the basepan. This fitting is designed to accept 3/4" clear vinyl tubing which can be pushed on by hand and run to a suitable drain. Many people have mistaken the condensation for a water leak inside the unit. NOTE: A quick way to verify that the water is condensation is to shut off the unit and keep the pool pump running. If the water stops running out of the basepan, it is condensation. AN EVEN QUICKER WAY - TEST THE DRAIN WATER FOR CHLORINE - if the is no chlorine present, then it's condensation. 5 6