New LAE controller for Plug-in cabinets

Similar documents
TABLE OF CONTENTS. 1. Technical specifications of the appliance 2

0LLCD003EN STANDBY NORMAL INFO MENU INFO DATA SETUP MENU PARAMETER VALUE. Not Product Air Display scale Operating Temper. (sim.

COMMERCIAL REFRIGERATORS, STAINLESS STEEL PRODUCTS OPERATING INSTRUCTIONS

Service Manual. LC125 Meatwell with LDU15 Controller (Feb 04 till July 09) then AT1-5 Controller (July 09 onwards)

TRUE TEMPERATURE CONTROLS SEQUENCE OF OPERATION

Environmental Management Policy for Service Manuals and Duets.

PRO A CABINET & COUNTER

BSD SERIES REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

Service Manual. Slimline Range With LF28 Controller ISO ISO 9001

Original Service Manual

ER52 - Evaporator Controller

FlexDrawer. Original Service Manual. FFC6-2, 3-1, 4-2 & 2-1 Models. FD2-10 Controller & LCD5S Display. English

Original Service Manual

Service Manual. Slimline Range with FD2-10 Controller ISO ISO 9001

Service Manual. EPrem Cabinets & Counters with FD2-10 Controller ISO ISO 9001

BLG-HGP Model Bottom Mounted Full-Length Swing Glass Door Freezer Merchandisers

Maintenance Manual VCS

EC 6-295P220S001. smart guide 2 OPERATION. 2.1 How to turn the instrument ON/OFF. If you have to turn the instrument ON/OFF:

Multideck Display Cabinets

DIMENS. MIN TYPICAL MAX A 71.0 (2.795) 71.0 (2.795) 71.8 (2.826) B 29.0 (1.141) 29.0 (1.141) 29.8 (1.173)

BS-316. Gas detection control panel up to 16 inputs. Installation operation manual

Thermometers and temperature controllers

COMMERCIAL REFRIGERATORS, STAINLESS STEEL PRODUCTS REFRIGERATORS OPERATING INSTRUCTIONS

ER65 - Mini Rack Controller Electronic Refrigeration Line

User Guide. OPTYMA TM Control Three-phase AK-RC 103

DFZ. Cabin Control Description and operation

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS for HOAM and VOAM Open Air Merchandisers

SERVICE MANUAL REFRIGERATION

Lubrication cycle IP Enclosure Rating. 110 VAC, 220/230 VAC (50/60 Hz) Alarm Fault Relay Contacts. IP-55 (Liquid tight connector)

Installation & Operations Manual for. BLG-HGP Model Bottom Mounted Full-Length Swing Glass Door Freezer Merchandisers. 6/17 Rev.

1 NORMS AND REGULATIONS Guarantee norms: Environmental notes: Identification:... 15

URS-1 SERVICE AND PARTS MANUAL SERIAL NUMBERS: UP TO

Refrigeration and Air Conditioning Technical leaflet. Electronic controller EKC 201 and EKC 301

Updated: 17/03/2010 ELECTROLUX. CAREL ir33. Quick reference Handbook. Ver. 1.1 Eng. Pag.1/12

Label Displayed temperature Pb1 if the P4 parameter is set to 0, 1 or 2, room temperature if the P4 parameter is set to 3, incoming air temperature

INSTRUCTIONS AK-CC 250A

DFZ. In Cab Control Description and Operation

CAREL IR33+ CONTROLLER

SAS6000UTK-7 UNIVERSAL THERMOSTAT

MODEL URS-1: FACTORY RETROFIT PROGRAM

CAREL CONTROLLER. Programming Instructions HOW TO CHANGE LEVEL 1 CONTROL SETTINGS HOW TO CHANGE LEVEL 2 CONTROL SETTINGS

Instructions of use and maintenance page 2 Electric and refrigerating diagrams page 3 Manual of the thermostat page 4 Spare parts page 6

MINITOP Refrigerated Self-Service Display underneath

Dixell Installing and Operating Instructions release 7.0

Rieger. Industrievertretungen GmbH. Vertrieb durch: Ihr Anbieter für Geräte im Bereich Labor, Mikrobiologie und Industrie. Wir sind für Sie da:

DPC-1 Programmable digital thermostat with communication Versión 2.0. Technical Information. Ref: N

Ocean Breeze Model QU700 Programmable Digital Touchscreen Climate Control

Installation & Operations Manual Master-Bilt Products 908 Highway 15 North New Albany, MS Phone: (800)

Installation & Operations Manual. Master-Bilt Products 908 Highway 15 North New Albany, MS Phone: (800) /17 Rev.

OMNITOP Refrigerated Display with Ventilated Cooling

Ice Cream Cabinet mod. La Rossa

PARAGON Commercial Refrigeration Controls

Installation & Operations Manual Master-Bilt Products 908 Highway 15 North New Albany, MS Phone: (800)

Ocean Breeze Model QU700 Programmable Digital Touchscreen Climate Control

User manual CLIMATIC 200/400 - Controller. Providing indoor climate comfort

User Guide ems25plus. Page 1. Normal operation. Product interface

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

REMOTE CONTROL FOR CHILLER MYCHILLER

Bottle cooler controllers Solutions for static, ventilated and open coolers

CTT8 TEMPERATURE MONITOR DEVICE

ER65-DRW Controller. Heating Applications. Product Bulletin. Heating Controller

Capacity controller for water chiller AK-CH 650

ELECTRONIC AIR CONDITIONING CONTROL

Modular Standard HP Chiller 1/4 screw compressor with Carel driver

INSTRUCTION FOR THE USER THC V E OIL BLU

SAS6000UTK-7-WIFI OPERATING INSTRUCTION

Sapphire Series TSVW & TWWS Chillwater Digital Thermostats

BASIC 700 OPERATOR MANUAL

Installation, Operating and Maintenance Manual

QTFX-LF900 Low-Level Fog Machine User Manual

EasyTronic III MANUAL SERVICE

Installation & Operations Manual. Master-Bilt Products 908 Highway 15 North New Albany, MS Phone: (800) REV: LN PN

ENERGY LIGHT USER S GUIDE ENERGY LIGHT USER S GUIDE

Flopurge TS. Operation Manual

EVF815 Installer manual ver. 2.0 Code 144F815E204 EVF815

3/15 Rev B

Janfire Pellet Burner Boiler. for single / double burner management (Version 1.1)

SERVICE MANUAL REFRIGERATION

EVF818 Installer manual ver. 1.0 Code 144F818E104 EVF818. Split execution controller for temperaturecontrolled

BSR Addressable Fire Detection control panel. Installation operation manual

T-SERIES FREEZER / REFRIGERATOR SWING & SLIDE DOOR

WATER HEATER ELECTRONIC CONTROLLER USER MANUAL

MLCFC HMI NAVIGATION MANUAL

SLV CONTROLLER 105N46XX SERIES

Refrigerated air dryers

ZSC100 Gas Detection and Alarm System Controller

Temperature + Humidity (%RH) Control & Recording System with 8 / 16 Channel Mapping. Touch Panel PPI

XWA11V-KIT Walk-In Temp / Door /Alarm / Light Module with Mounting Box and Wiring

DIGITAL ALARM UNIT Model ALU-AP

TPOne-B. Electronic Programmable Room Thermostat. Installation Guide. Danfoss Heating

Smart Temp. Model

HP727S. Single speed swimming pool heat pump controller Operation manual TABLE OF CONTENTS

CONTROL DEVICE SLIDETRONIC HD

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

Refrigerator KE T

Telephone Helpline: (Australia) Blast Chiller / Freezer. Instruction Manual. Model DN492-A DN494-A

technical bulletin Control Link RSC Installation Instructions

Follett Performance Plus

Operating instructions Page 12

Menvier Fire System MF9300

Transcription:

From: Lonardi [MC] To: Price-list owners Ref.: P-6.006/01 Date: 19/03/01 New LAE controller for Plug-in cabinets Dear Sirs, with the aim of a continuous improvement we are going to introduce our new LAE electronic controller in our plug-in cabinets: CRONOS IT2000X GLYCOS PROTEUS PLUS The reason that drive us to make this change is the better performance of LAE controller compared with EC 10 controller actually assembled in plug-in cabinets. LAE performance The advantage of LAE controller depends on some additional features as: Easy to use consolle that integrates all electrical and electronic switches in one compact board. Possibility to use the third probe that monitors the running temperature inside the cabinet (not in air suction or air intake). Intelligent management program that reduces power consumption because it is possible to use a day and a night setting in order to optimise the use of night covers or sliding doors (where available). Criosbanc Product Management page 1/2

Ref.:P-6.006/01 date: 19/03/01 Easy maintenance of the controller as it is composed of two easy replacing parts; the consolle and an electric/electronic integrated circuit connected each other and with the cabinet components with faston wiring easy to replace and to connect. For additional information about LAE controller see Product Info P-1.002/00(56). Timing of LAE introduction The start of production of LAE electronic controller is planned for beginning of week 18 (30 th April 2001) and deliveries will follow after end of stock. Note also that will be issued a price-list update as the codes of these cabinets will change. Best regards Gian Lonardi Criosbanc Product Management page 2/2

EC LAE CONTROL PANEL THE BUTTONS ON THE CONTROLLER ALLOW: - Turning the controller on or off ("ON" led off, "OFF" led alight). - Turning the cabinet hood lights on ("ON" led alight, "OFF" led off); - passing from a parameter to the previous one; - reducing the value associated with the parameter; - turning the lights on under the middle shelf (optionals) ("ON" led alight, "OFF" led off); - passing from a parameter to the following one; - increasing the value associated with the parameter; - activating manual defrosting; - turning the demisting ventilator on ("ON" led alight, "OFF" led off). This is used when the cabinet is positioned in a very damp area, which could cause the formation of condensation on the glass; - returning to the display function; - visualising the value associated with the chosen parameter; - accessing the parameter menus. THE LIGHTED LEDS INDICATE: - Compressor working; - Belly section ventilation working; - Defrosting working. The control panel is fitted with a user interface, which contains a three-figure display and a keyboard with five function buttons. NORMAL WORKING STATUS During normal working, the display shows the actual temperature inside the cabinet. USER PROGRAMMING STATUS On installation, the user needs only programme the working temperature for the cabinet. To set this function, the user must depress the button and then "SEL" appears on the display. Using the buttons and the given value can be increased or decreased until the desired value is reached. To terminate the operation, release the button. The working temperature to set on the electronic chart must coincide with the temperature indicated by the manufacturer of the goods displayed (see recommended conservation temperature printed on the product packaging). GB - Cod. 72004200 Pag. 1/2 MC - 06/02/2001

NUMBER OF DAILY DEFROSTINGS The number of daily defrostings is equally divided throughout the 24 hours. Defrosting time depends on the temperature after defrosting, which is checked by a probe connected to the control panel. However, defrosting time cannot exceed a maximum time, which is controlled by the electronic chart and varies depending on the defrosting version used: - defrosting by blocking refrigeration: 4 cycles maximum duration 60 minutes (Cronos e Glycos). - electrical defrosting (optional Cronos): 4 cycles maximum duration 30 minutes (Cronos) and 35 minutes (Proteus Plus). When immediate defrosting is required, button must be pressed once and then again until the "df" abbreviation appears. Press and keep depressed followed by. During the defrosting cycle, the display shows the last temperature taken before beginning the cycle. ALARM STATUS The controller allows checking that the thermostat is working correctly, the periodic signal for condenser cleaning, besides the functional and anomaly alarms of the T1, T2 and T3 probes. When an alarm is set off, the controller activates the specific relay and signals the anomaly, by flashing the relative LED, ALR appears on the display and a sound alarm is set off. If a new alarm occurs, press button, the ALR indication can be removed permanently, the buzzing silenced and the cause of the alarm can be seen. The indications on the display are: - A L low temperature; - A H high temperature; - A C condenser cleaning; - A 1 anomaly with probe T1 (delivery); - A 2 anomaly with probe T2 (evaporator); - A 3 anomaly with probe T3 (suction). By pressing button, the buzzer is silenced after which, if the alarm continues, it is activated periodically for 20 seconds every hour until the alarm ceases. This is valid for all alarms, except the condenser cleaning alarm. The alarm led and relay are always activated while the alarm persists. IF THE CONTROLLER IS TURNED OFF OR PUT IN STANDBY, THE COUNTERS AND ALARMS ARE ZEROED. However, if any sort of alarm persists, the user must contact the nearest service centre. THERMOMETER (OPTIONAL) Battery cover WARNING. The thermometer is fed by a D357H 1.5V battery supplied as standard. If it is off on installation: extract the thermometer from the appropriate support place under the shelf and gain access to the battery by unscrewing the rear cover and removing the insulation (film or piece of paper) placed behind the battery to prevent running down. Thermometer rear view GB - Cod. 72004200 Pag. 2/2 MC - 06/02/2001

SETTING THE LAE CONTROLLER PARAMETERS PARAMETERS: The password must be entered to view and/or change any of the parameters. ENTER PASSWORD: The display must be working normally (showing the cabinet temperature); press button once, followed by button repeatedly until "Pc" is displayed; press and keep pressed button (code "00" is displayed) press button rrepeatedly until the access code (password) "250" is displayed, release the button ; the first parameter to be modified is displayed. CHANGING THE PARAMETERS: With buttons and the parameter menu can be viewed; when the parameter to be changed is displayed, press and keep pressed button,, this parameter change is accessed and using buttons and, the displayed value can be increased or reduced until the desired value is reached; release the button, the controller automatically passes to the following parameter. EXIT FROM THE DISPLAY OR PARAMETER CHANGE TAKES PLACE BY PRESSING BUTTON OR AFTER 30 SECONDS WITHOUT THE KEYBOARD BEING USED. GB - Cod. 72003960 Pag. 1/1 MC - 02/10/2000

PARAMETERS TABLE FOR CABINET WITH LAE CONTROL PANEL CRONOS To modify the configuration parameters use the password=250 72004040 72004050 aut.defrost elec.defrost SPL Minimum set allowed C/ F -10-10 SPH Maximum set allowed C/ F 15 15 SP Main set point C/ F 2 2 HY Main thermostat delay C/ F 2 2 NSP Night set point C/ F 3 3 NHY Night thermostat delay C/ F 3 3 DFR Defrosting frequency n 4 4 DLI Defrosting end temperature C/ F 12 12 DTO Maximum defrosting duration min 60 30 DTY Defrosting type (OFF/ELE/GAS) OFF ELE DRN Dripping time min 2 2 DDY Display control during defrosting min 10 10 FDC Fan control during defrosting (END/THS/CON) CON CON FRT Fan delay after defrosting C/ F 50 50 ATL Lower alarm threshold C/ F -7-7 ATH Upper alarm threshold C/ F 10 10 ATD Temperature alarm delay min 60 60 ATI T1/T3 control alarm probe T1/T3 T1 T1 ACL Condenser cleaning interval time weeks 0 0 CRT Compressor stop min 4 4 CDC Security cycle 0,,,10 5 5 HEA Heating function starting Yes/No NO NO NGT Night function starting Yes/No NO NO T2 T2 probe starting Yes/No YES YES T3 T3 probe starting Yes/No YES YES TDI Display selection T1/T3 T1 T1 SCL Display scale C/ F C C OS1 T1 probe correction C/ F 0 0 OS2 T2 probe correction C/ F 0 0 OS3 T3 probe correction C/ F 0 0 ADR Peripheral unit address 0,,,255 0 0 U.M. GB - Cod. 72004040 Pag. 1/1 MC - 29/11/2000

LEGEND FOR THE PLUG IN ELECTRICAL DIAGRAMS Terminals 6 to 8 = contact output N.O. MAX. 2A (remove jumper from terminals 5 and 6) Terminals 8 to 10 = refrigeration output 230V 50Hz 1PH+N MAX. 2A Electric panel. Lighting ballast box. Control dash-board. Display case length. Lamps/ballast rated electrical powers. Rated power referred to 230 Vac 50 Hz mains supply. Refrigeration outlet max. 2A AC3. Presence and features of electrical components or user elements. 230 Vac 50 Hz supply, 1PH+N+Gnd. Refrigerated unit control electric wiring diagram. 8-11 = N.O. clean contact refrigerator outlet (remove cable 32 in terminals 10 and 11). 8-9 = 230 Vac 50 Hz refrigeration outlet, max. 6A AC1. AA Open angle. AC Closed angle. A31 Control card for refrigerated unit. A58 Display card. A67 Speed change for motor-driven fan. B15 Control level water switch. B23 Evaporator temperature probe. B24 Room temperature probe. D00 Compressor 2 delaying device. D14 Timer. E00 Upper lighting. E02 Anterior front apron lighting - optional. E03 Interim shelf lighting. E10 Condenser unit. F0G A31 card primary fuse. F00 Refrigeration outlet fuse. F03 Fuse for R34-E00-E03-R11. F05 Fuse for auxiliaries M66-M111-M112. F001 Compressor 1 fuse. F002 Compressor 2 fuse. F4A1 Compressor 1 high pressure pressure switch. F4A2 Compressor 2 high pressure pressure switch. K00 Remote switch for refrigeration outlet. K001 Compressor 1 remote switch. K002 Compressor 2 remote switch. L0_ Fluorescent lamp ballast. M011 Motor driven compressor n 1. M012 Motor driven compressor n 2. M111 n 1 Condenser unit fan. M112 n 2 Condenser unit fan. M66 Evaporator motor driven fans. R-C Anti-noise filter. GB - Cod. 72000240 Pag. 1/2 VD - 07/11/97

R11 Evaporator defrost resistance element. R34 Anti-fog resistance element. R37 Re-evaporation water heater. S4B Night temperature thermostat (only with night cover) remove the cable that is between terminals 4 and 5. S4I Safety heater thermostat. S44 End-defrost thermostat. S13 Anti-fog resistance element switch. S17 Display case lighting switch. S19 Display case supply switch. S45 Temperature thermostat. S171 Line n 1 light switch. S172 Line n 2 light switch. T3A Controller supply transformer for refrigerated unit. V0 Fluorescent lamp. W00 Flat. XA Terminal block for to be earth-wire wiring. X2C 2 poles terminal. X2I Insulation derivation terminal. X00 User connector terminal board. X00_1 Display case supply terminal box. X00_2 Terminal box for defrost resistance element outlet and condenser unit or solenoid valve. L-N = refrigeration outlet. 220 Vac 50 Hz max. 2A (AC3). X40 Power supply connection for re-evaporatin water heater. X50 Plug for the re-evaporatin water heater. X60 Display case supply plug. Connect to mains 220/230 Vac 50 Hz. Y13 Liquid line solenoid valve. Y15 Hot-gas defrost solenoid valve. GB - Cod. 72000240 Pag. 2/2 VD - 07/11/97