TECHNICAL SPECIFICATION

Similar documents
TECHNICAL SPECIFICATION

Silencer Preheater unit Electric post-heating unit Water circulated post-heating unit CO 2 sensor %RH sensor Pressure difference switch LON converter

Vallox INSTRUCTIONS FOR USE AND MAINTENANCE. Compact. Supply and extract air ventilation with heat recovery

TopMaster Air Handling unit. Technical data

Models Vallox 096 MC R Vallox 096 MC L. Document D2609 MANUAL. Valid from Type Updated Manual.

TECHNICAL SPECIFICATION

Air heater/cooler in combination with ground source heat pump

Fresh air unit ALB. ALB it s simple and so easy! Air supplied through a heater and filter in a single unit.

eco PREMIUM ENERGY RECOVERY UNIT» Technical instruction

Swegon CASA W130. Ventilation unit with counter-flow plate heat exchanger HOME VENTILATION

290 on. 286 on. Comfortable climate with pre-heated, filtered supply air. Fresh air boxes ALB WW MODEL WITH WARM WATER HEATING

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

Heat recovery unit RDKS

KOMFORT EC DB Suspended heat recovery air handling units

145SE. Vallox. Operating, maintenance and technical instructions

Technical Data OPA 101, 150, 180. Ducted Three Phase Packaged Air Conditioner kw 18.5 kw. Extra Long Life Epoxy Coated Outdoor Coil

AIR HEATING UNIT HEATMASTER ACJB INSTALLATION, OPERATION, MAINTENANCE AND SPARE PARTS

TopMaster Air Handling unit. Installation instructions

FLEXIT S4 X/TT - A4 X/TT S7 X/TT - A7 X/TT

PRODUCT DATA COMFORT 600 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 800 m 3 /h

MAXI CENTRALIZED VENTILATION WITH HEAT RECOVERY

Series VUT PW EC. wool internal heat and sound-insulating layer for VUT PE/PW 350, 600, 1000 units and 50 mm for VUT PE/PW 200, 3000 units.

Air Handling Unit. REC Temovex Blue 4 NEW! Experts on indoor climate in low-energy houses

DUCTIMAX 2-8 kw. Medium available static pressure ducted hydronic units. Duct unit DUCTIMAX

TECHNICAL MANUAL FOR AIR-COOLED CONDENSING UNITS MTE

Technical Data Ducted Three Phase Split System Air Conditioner

Flexit air handling units C2 and UNI 2, 3,4

096SE. Vallox. Operating, maintenance and technical instructions

STR-600 Impact Dryer

IN LINE MIXED FLOW DUCT FANS AND ELECTRIC HEATER TD-MIXVENT HEATING System

Vallox Oy. manufactures. over LOW POWER EFFICIENCY Specific electrical

TopMaster Air Handling Unit

Vallox Oy. manufactures ventilation units Vallox TSK Multi 80 MC. over Vallox TSK Multi 80 MC

Series VENTS VUT R WH ЕС

panel filters with filtering class G4. Supply filter F7 can be supplied with the few models.

CUMULUS CUMULUS. Key figures. Construction. Function Integrated chilled beams

panel filters with filtering class G4. Supply filter F7 can be supplied with the few models.

HEAT RECOVERY AND HEAT AND HUMIDITY RECOVERY AIR HANDLING UNIT

USER MANUAL. Frigate HRV 120 SR Frigate ERV 120 SR. Heat (energy) recovery ventilation unit

Flexit air handling units UNI 2, 3 og 4

HEAT RECOVERY AIR HANDLING UNIT

Primo Hotel. General. Indoor climate units for hotel rooms

Supply air unit VEKA Installation & Maintenance

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

TURBO HOODS. Product Brochure

INSTRUCTION MANUAL FOR OIL BURNER MODELS

PRODUCT DATA COMFORT 300 TOP BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 325 m 3 /h

TECHNICAL MANUAL YEFB HIGH PRESSURE DUCTED UNIT

Swegon CASA R120. Ventilation unit with rotary heat exchanger HOME VENTILATION

GLOBAL LP. Ceiling-mounted ventilation unit with plate heat exchanger

Series. Suspended air supply units with the air capacity up to 4100 m 3 /h in the sound- and heat-insulated casing with the water heater

ELFODuct MP. Technical Bulletin. New generation horizontal and vertical built-in water-source ductable terminal for medium and large systems

CHH - Active Chilled Beam. Halton CHH. Active Chilled Beam

JSI-UV canopy - Ultraviolet and cyclonic filters, and supply air JSI-UV hoods Product Description Lights and filters

USER S MANUAL. Heat Recovery Ventilator. Vents Brig HRV 200 Vents Brig HRV 300

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

Packaged air conditioning unit condensed by air model RTC 07L to 30L. Technical information. Ref.: N

INSTRUCTION MANUAL FOR OIL BURNER MODELS

RIS V EKO A1/L2 RIS 700 V E L EKO 3.0 AIR HANDLING UNITS. Application

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED

MODEL: BV400 Part No:

42AM. Air heaters PRODUCT SELECTION DATA

DX SYSTEM HEAT RECOVERY ENHANCED BY DEMAND CONTROLLED VENTILATION

Series VENTS MPA...W. Supply units with the air capacity up to 6500 m 3 /h in the compact sound- and heat-insulated casing with water heater

Technical Guide. Installation, Operation and Care. EP E series 7 step electric boilers 26 and 42 kw

DESIGN & TECHNICAL MANUAL

PRODUCT DATA COMFORT 5000 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 5300 m 3 /h

> ENGLISH VERSION. Instructions HERU 50 HERU / utg 2

KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S. Heat and Energy Recovery Ventilators

Framework is anodised aluminium with airtight door seals and manual door catches which can be tool locked in position.

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

KN-KWL 110 SE-EC Kontrollierte Wohnraumlüftung KN

TEMSPEC INC. VERTICAL FAN COIL UNIT MODELS TVA, TVE, TVS

Ventilation Unit Zehnder ComfoAir 350

VERSO Air Handling Units

Bruksanvisning Directions for use

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE

That allows for installation of a lowresistance ducts system directly from the appliance. CONSTANT FLOW FANS

Vertical Stack Fan Coil Units Models: TVA, TVE, TVS

SAM. Small Air Handling. VES SMALL AIR HANDLERS part of a complete range of innovative, flexible products from the HVAC experts

Heat Recovery Unit HERU. web-version

HEATING AND VENTILATION

Application guide FLATAIR - FLCK/FLHK. Providing indoor climate comfort

Compact Horizontal Air-Air Heat Pump Model RTH 07L to 30L. Technical information. Ref.: N

TSEK VHR EC HEAT RECOVERY UNITS

LTR-3-EC LTR-3-ECE PLANNING, INSTALLATION AND OPERATION INSTRUCTIONS

Vertical Air Handler Unit

TEVHR. Heat Recovery Ventilator

PRODUCT DATA COMFORT 1200 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 1400 m 3 /h

Adsolair 56/58. Comfort air conditioning unit with double plate heat exchanger and adiabatic evaporative cooling system

Air to Air Heat Exchanger

Technology for life. Unit heater LH

CONTENT: VEX308 Decentralised ventilation VEX308

Residential Heat Recovery Ventilation. REHVA European Guidebook No 25

VIESMANN VITOVENT 300-F Mechanical ventilation system with heat recovery

Novenco Air Handling Units. Climaster ZCP June 2005

UV-TURBO HOODS. Product Brochure

HEAT RECOVERY UNITS TSEK. Mech-Elec, 41, Hawthorn Road, Western Ind. Est., Dublin 12 Tel:

Homepage > Products > Decentralised ventilation systems > Vertical units > Type FSL-V-ZAB/SEK FSL-V-ZAB/SEK

AIR HANDLING UNITS ASSET REFERENCE: DESIGN AHU 1 AHU 2

Transcription:

VALLOX-product code: HVAC code: 358500 L 35850 R 79076 L 79077 R SOUND ATTENUATOR (OPTIONAL) IVALLOX 252 WATER OPERATED POST- HEATING UNIT (OPTIONAL) ELECTRICAL POST-HEATING UNIT (OPTIONAL) ELECTRICAL PREHEATER (OPTIONAL) TECHNICAL SPECIFICATION Fans Supply air 2x230 W A Discharge air 2x230 W A Heat recovery Heat recovery bypass Preheater Electric post-heating unit Water post-heating unit Filters Supply air Discharge air PRESSURE DIFFERENCE SWITCH (OPTIONAL) Power supply 230 V, 50 Hz, (230 V / 400 V) 3,9 A (+preheater 0,9 A) Protection class IP 34 Weight/basic unit Ventilation adjustment options Options 20 dm 3 /s 00 Pa 230 dm 3 /s 00 Pa 2 heat recovery cells, η>70 % Manual or remote monitoring control 2,5 kw A 2,5 kw A Approx. 5kW EU 3 EU 7 EU 3 EU 5 20 kg manual control (manual control unit) remote monitoring control sound attenuator preheater electric post-heating unit water post-heating pressure difference switch unit MANUAL CONTROL CENTER REMOTE MONITORING CONNECTION

OPERATING PRINCIPLE OF THE VENTILATION UNIT Models: L R removes contaminated air and replaces it with filtered and heated outdoor air. Efficient filtering of outdoor air (EU3 + EU7) prevents harmful particles from entering the ductwork and rooms via the unit. Good filtering of discharge air (EU3 + EU5) diminishes the contamination of the unit and ensures effective operation of heat recovery and the discharge air fans. Clogging of the filters and the ductwork can be monitored if the unit is equipped with pressure difference switches. With efficient 2-step heat recovery, most of the heat of contaminated discharge air can be transmitted to outdoor air coming inside. The efficiency of the heat recovery cells is approx. 70%, or 75...80% if supply air fan heat is taken into account. If outdoor air does not get sufficiently warm in the heat recovery cells, it is possible to use an (optional) heating unit operated by water or electricity. In the summertime, needless heating of outdoor air can be avoided with the heat recovery bypass function, operated either manually or by remote control. The automatic defrosting of the heat recovery cells intermittently stops the supply air fans when the temperature of discharge air goes under the pre-set threshold value. To avoid or to decrease the stopping of the supply air fans, supply air can be heated with an electrical preheater. If the unit is equipped with a preheater, defrosting starts when outdoor air temperature goes below ca. -5/-25 C (max./min. supply air stream). Without preheating, the operation starts when outdoor air temperature falls below ca. -5 C. can be operated with the manual control unit contained in the delivery. With the manual control unit, you can select the min. or max. ventilation power, and stop the unit. The control unit also features a heat recovery bypass switch. The manual control unit cannot be used in remote monitoring control. In remote monitoring, you can stop the unit, and adjust three different power positions (min, half, max). Heat recovery bypass can also be controlled in remote monitoring. Control voltage in remote monitoring is 24 VAC. The unit gives potential-free signals of operation modes of the selected power positions and the optionally installed pressure difference switches of the ductwork. The unit can supply control voltage (24VAC) to separate damper motors of the outdoor air and extract air ducts. This control voltage is switched off when the unit is stopped. The function can be used in both manual and remote monitoring control. The separate damper motors are not included in the delivery. 8 2 5 4 3 -L A B C D 370 60 + (Door and insulation 55 mm) = OUTDOOR AIR = SUPPLY AIR = DISCHARGE AIR = EXTRACT AIR Sound attenuator unit 3 Installed above the unit * detachable inner coupling 9 A B 2370 C 2 000 370 87 VALLOX M 252-R 665 222 Ø250 4Pcs.l A B C D D * 282 7 6 4 = EXTRACT AIR = DISCHARGE AIR = SUPPLY AIR = OUTDOOR AIR 220 220 00 222 0 220 87 220 Main parts 2 3 4 5 6 7 8 9 0 Optional equipment 2 3 4 Supply air fans Discharge air fans Heat recovery cells Heat recovery bypass Supply air filter EU7 Discharge air filter EU5 Discharge air filter EU3 Outdoor air filter EU3 Post-heating unit water operated or electrical Preheater electrical Pressure difference switch unit 00 87 222 282 222 87 Condensing water reservoir Condensing water outlet Electrical connection lead-throughs Ø 250 Pcs. Internal outlet collar 2

FAN CAPACITY PERFORMANCE Measuring Points Supply air Discharge air Pressure loss in ducts. Total pressure Suositeltava Recommended toiminta-alue operating range T Model L Measuring points after the outlet collar. Fan curves indicate the total pressure available for duct losses. P Fan speeds Control voltage V Air flow l/s Input power W Volume flow rate Fan curves: P = discharge air fan, T = supply air fan 2 3 4 5 6 7 8 90 00 0 30 40 60 200 230 80 95 0 35 50 75 205 230 200 230 275 350 390 450 590 675 with Sound Attenuator FAN CAPACITY with Sound Attenuator Measuring Points Supply air Discharge air Pressure loss in ducts. Total pressure Recommended operating range Model L Measuring points after the outlet collar. Fan curves indicate the total pressure available for duct losses. Fan speeds Control voltage V Air flow l/s Input power W Volume flow rate Fan curves: P = discharge air fan, T = supply air fan 2 3 4 5 6 7 8 90 00 0 30 40 60 200 230 74 85 99 27 43 70 206 220 200 230 275 350 390 450 590 675 3

SOUND VALUES Sound power levels in the ducts measured in accordance with the standard ISO/DIS 535:995. Sound pressure levels in the room (0 m 2 sound absorption) determined according to the regulation 4873/53/84 issued by the Finnish Ministry of Environmental Affairs Hz 63 Medium 25 frequency 250 of the 500 octave 000 band, 2000 Hz 4000 8000 L w, db L w A db(a) L p A, db(a) Sound power level from VALLOX to supply air ducts by octave band L w, db CONTROL POSITION / AIR FLOW 4 6 38 l/s 69l/s 76l/s 62.0 55.0 48.0 36.0 38.5 28.5 20.0 63.0 44.0 65.5 60.0 55.5 44.5 43.5 38.5 30.0 20.0 66.5 50.5 68.0 63.5 6.0 49.5 47.0 45.0 35.0 27.0 70.0 55.5 Sound power level coming from VALLOX through the envelope to the rooms where the unit has been installed CONTROL POSITION / l/s 78/85 33 4 29/39 L p A = A-weighted sound pressure level (0 m 2 sound absorption) 40 6 66/76 44 8 208 l/s 69.5 67.0 64.5 54.5 50.0 50.0 39.5 32.0 72.0 59.0 8 22/27 47 Sound power level from VALLOX to discharge air ducts by octave band L w, db CONTROL POSITION / AIR FLOW 4 6 4 l/s 79/s 85 l/s 63.0 59.0 47.5 36.5 36.0 28.0 5.5 64.5 45.0 68.5 66.0 57.0 43.5 43.5 38.5 28.5 8.5 70.5 53.5 72.0 68.5 6.0 48.0 48.0 45.0 34.0 27.0 74.0 57.0 8 226 l/s 74.5 72.0 66.0 52.0 49.5 49.5 38.0 3.0 77.0 6.0 Hz Sound power level from VALLOX to supply air ducts by octave band L w, db CONTROL POSITION / AIR FLOW 77 l/s Medium frequency of the octave band, Hz 63 25 250 500 000 2000 4000 8000 L w, db 55.0 52.0 33.0 8.0 3.5 4.0 57.0 6.0 57.5 40.5 27.5 6.0 62.5 63.0 60.0 46.5 35.0 25.0 9.0 65.0 66.5 62.5 50.5 4.5 32.0 27.0 5.5 68.0 L w A db(a) 35.5 4.0 44.5 48.0 Sound power level coming from VALLOX through the envelope to the rooms where the unit has been installed CONTROL POSITION / l/s 74/82 Sound power level from VALLOX to discharge air ducts by octave band L w, db CONTROL POSITION / AIR FLOW L p A, db(a) 32 38.5 43 46.5 with Sound Attenuator L w A, db(a) 36-* 42.5-* 47-* 50.5-* L w A = A-weighted sound pressure level * = difference between sound power level and pressure level when unit location and total absorption area are taken into account (in a classroom, for instance, t.ex. L w A -* = 2 db) 24 4 33 l/s 4 3/38 6 69l/s 6 67/75 8 209 l/s 8 208/22 80/s 55.5 53.5 34.0 57.5 37.0 4 35 l/s 59.5 59.0 43.0 25.5 7.0 62.5 42.5 6 67 l/s 63.0 62.5 48.0 3.0 24.5 20.5 65.5 46.5 VALLOX 252 8 204 l/s 67.0 65.0 5.5 36.5 30.0 27.0 8.5 69.0 49.5

Pressure Loss in the Water Radiator WATER RADIATOR PERFORMANCE The recommended area of operation is ruled. Determined for 00% water. Total pressure loss kpa Radiator + valve (KVS.0) Radiator Water flow dm 3 /s dm 3 /h Water Radiator Output Temperature of water entering the radiator (tv) 70 C Temperature of air entering the radiator (ti)5 C Water flow dm 3 /s Temperature of water entering the radiator (tv) 55 C Temperature of air entering the radiator (ti)5 C Water flow dm 3 /s Total output of the radiator kw Air flow dm 3 /s Total output of the radiator kw Air flow dm 3 /s Cooling of water in the radiator C Cooling of water in the radiator C 5

CONTROL DIAGRAM - MANUAL CONTROL Control Diagram - MANUAL CONTROL UNIT Distribution Panel 2x6A if equipped with a preheater Internal electrical and control connections Post-heating unit, electric Preheater, electric Sound attenuator Manual control unit VENTILATION ZONE 26

DESCRIPTION OF OPERATION - MANUAL CONTROL UNIT Control of Operation The ventilation unit can be stopped by the fan speed switch on the manual control unit. Fan Speed Adjustment The users can control the fan capacity of the ventilation unit in two steps using the speed selection switch on the manual control unit (H) in the ventilation zone. Supply Air Temperature The control / adjustment center of the unit directs the operation of the post-heating unit (LP2) on the basis of the measuring data on the sensor of the TS2 temperature thermostat, aiming at keeping supply air temperature at the temperature value set with the TS2 thermostat (0...25 C). Heat Recovery Bypass Heat recovery can be bypassed using the Summer / Winter switch on the manual control unit (H). When the switch is in the Winter position, heat recovery is on. The Summer position bypasses heat recovery and deactivates the preheater (LP), if used, and the post-heating unit (LP2). Parts List Heat Recovery Defrosting The TS5 temperature thermostat directs the operation of the preheater (LP) on the basis of the measurement data supplied by the temperature sensor, preventing the risk of freezing and the stopping of the supply air fan (TF). If the capacity of the preheater (LP) is not sufficient, or if there is no preheater, the TS defrosting thermostat of the heat recovery cells stops the TF supply air fan on the basis of the measuring data on the temperature sensor, thereby preventing the heat recovery cell from freezing. As soon as the risk of frosting passes, the fan restarts automatically. The threshold temperature for defrosting (-2...+6 C) and the difference area (2 C) can be set on the thermostat. Overheating Protection of the Heating Unit Overheat protection thermostats TZ and TZ2 monitor the surface temperature in the LP and LP2 heating units. If surface temperature exceeds the threshold, overheat protection is triggered and power supply to the heating unit is stopped. The TZ overheating protector is reset automatically, and the TZ2 protector manually. Damper Motors of the Outdoor and/or Extract Air Ducts The spring return damper motors (24VAC) that may be installed outside the ventilation unit, in the outdoor or extract air ducts, can be controlled with control voltage (24 VAC) coming from the ventilation unit: when the ventilation unit is stopped, also the control voltage fed from the unit is stopped. Code Name Technical details Equip- Delivery (factory settings in parentheses) Note! ment responsibility FG Damper motor Automatic heat recovery bypass 24V, 2W, 8Nm Standard X IU H Manual control unit Fan speed adjustment, control of heat recovery bypass Standard X IU LP Preheater Electric radiator 2.5kW Options IU LP2 Post-heating unit Electric radiator 2.5kW Options IU LTO Heat recovery cells 2-step, = 70 % Standard X IU LTO2 PF Discharge air fan qv = 230 dm3/s (00Pa) Standard X IU SU Filter Supply air EU7, discharge air EU5 Standard X IU TS Temperature thermostat Discharge air temperature Heat recovery defrosting Adjustment range -2...6 C (2) Standard X IU TS2 Temperature thermostat Supply air temperature Standard X IU Post-heating, electric TS5 Temperature thermostat Discharge air temperature Preheating, electric Adjustment range -0...8 C (2) Standard X IU TF Supply air fan qv = 20 dm3/s (00Pa) Standard X IU TZ Overheat protector of the electric radiator Automatic reset (+60 C) Included in LP / LP2 IU TZ2 Overheat protector of the electric radiator Manual reset (+95 C) Included in LP / LP2 IU FGU Damper motor Damper motor in the outdoor air duct (spring return) 24VAC IU FGJ Damper motor Damper motor in the extract air duct (spring return) 24VAC IU 7

CONTROL DIAGRAM VKL - MANUAL CONTROL UNIT Control Diagram VKL MANUAL CONTROL UNIT Distribution Internal electrical and control connections Post-heating unit (water circulation) Preheater, electric Sound attenuator Manual control unit VENTILATION ZONE 2 8

DESCRIPTION OF OPERATION VKL MANUAL CONTROL UNIT Control of Operation The ventilation unit can be stopped by the fan speed switch on the manual control unit. Fan Speed Adjustment The users can control the fan capacity of the ventilation unit in two steps using the speed selection switch on the manual control unit (H) in the ventilation zone. Supply Air Temperature A regulating valve (not included in the delivery) directs the operation of the LP2 post-heating unit on the basis of the measurement data given by the thermostat sensor in the supply air duct. The aiming is to keep supply air temperature at the temperature value set with the regulating valve (0...25 C) Heat Recovery Bypass Heat recovery can be bypassed using the Summer / Winter switch on the manual control unit (H). When the switch is in the Winter position, heat recovery is on. The Summer position bypasses heat recovery and deactivates the preheater (LP), if preheating is used. Parts List Heat Recovery Defrosting The TS5 temperature thermostat directs the operation of the preheater (LP) on the basis of the measurement data supplied by the temperature sensor, preventing the risk of freezing and the stopping of the supply air fan (TF). If the capacity of the preheater (LP) is not sufficient, or if there is no preheater, the TS defrosting thermostat of the heat recovery cells stops the TF supply air fan on the basis of the measuring data on the temperature sensor, thereby preventing the heat recovery cell from freezing. As soon as the risk of frosting passes, the fan restarts automatically. The threshold temperature for defrosting (-2...+6 C) and the difference area (2 C) can be set on the thermostat. Overheating Protection of the Heating Unit Overheat protection thermostats TZ and TZ2 monitor the surface temperature in the LP heating unit. If surface temperature exceeds the threshold, overheat protection is triggered and power supply to the heating unit is stopped. The TZ overheating protector is reset automatically, and the TZ2 protector manually. Damper Motors of the Outdoor and/or Extract Air Ducts The spring return damper motors (24VAC) that may be installed outside the ventilation unit, in the outdoor or extract air ducts, can be controlled with control voltage (24 VAC) coming from the ventilation unit: when the ventilation unit is stopped, also the control voltage fed from the unit is stopped. Code Name Technical details Note! Equip- Delivery (factory settings in parentheses) ment responsibility FG Damper motor Automatic heat recovery bypass 24V, 2W, 8Nm Standard X IU H Manual control unit Fan speed adjustment, control of heat recovery bypass Standard X IU LP Preheater Electric radiator 2.5kW Options IU LP2 Post-heating unit Water radiator 5kW, 70/50 C Options IU LTO Heat recovery cells 2-step, = 70 % Standard X IU LTO2 PF Discharge air fan qv = 230 dm3/s (00Pa) Standard X IU SU Filter Supply air EU7, discharge air EU5 Standard X IU SV Regulating valve Self-operating radiator thermostat Not included in the ventilation unit delivery TS Temperature thermostat Discharge air temperature Heat recovery defrosting Adjustment range -2...6 C (2) Standard X IU TS5 Temperature thermostat Discharge air temperature Preheating, electric Adjustment range -0...8 C (2) Standard X IU TF Supply air fan qv = 20 dm3/s (00Pa) Standard X IU TZ Overheat protector of the electric radiator Automatic reset (+60 C) Included in LP / LP2 IU TZ2 Overheat protector of the electric radiator Manual reset (+95 C) Included in LP / LP2 IU FGU Damper motor Damper motor in the outdoor air duct (spring return) 24VAC IU FGJ Damper motor Damper motor in the extract air duct (spring return) 24VAC IU 9

CONTROL DIAGRAM REMOTE MONITORING CONTROL Control Diagram REMOTE MONITORING CONTROL Distribution Panel 2x6A if equipped with a preheater Internal electrical and control connections Post-heating unit, electric Pressure unit Preheater, electric Pressure unit Sound attenuator Remote monitoring center of the property Alarm Operation mode Control Measurement Adjustment VENTILATION ZONE 20

DESCRIPTION OF OPERATION DIAGRAM REMOTE MONITORING CONTROL Control of Operation If needed, the ventilation unit can be stopped by controlling the contactors in the unit (Min., /2, Max.) or by controlling power supply via the contactor in the distribution panel. Fan Speed Adjustment The ventilation unit can feed control voltage (24VAC) to the remote monitoring center, and the remote monitoring center can then direct the fan capacity of the ventilation unit in three steps according to the control signal (24VAC) received by the Min., /2, and Max. contacts in the connection box. Remote monitoring receives potential free operation mode information on the mode selected (Min., /2, Max.). Supply Air Temperature The control / adjustment center of the unit directs the operation of the post-heating unit (LP2) on the basis of the measuring data on the sensor of the TS2 temperature thermostat, aiming at keeping supply air temperature at the temperature value set with the TS2 thermostat (0 25 C). Heat Recovery Bypass With the help of control voltage (24VAC) fed from the ventilation unit to the remote monitoring center and its control functions, the heat recovery bypass function can be directed according to the control signal (24 VAC) received by the NC contact in the connection box. When heat recovery bypass is activated, the preheater (LP), if used, and the post-heating unit (LP2) are deactivated. Parts List Heat Recovery Defrosting The TS5 temperature thermostat directs the operation of the preheater (LP) on the basis of the measurement data supplied by the temperature sensor, preventing the risk of freezing and the stopping of the supply air fan (TF). If the capacity of the preheater (LP) is not sufficient, or if there is no preheater, the TS defrosting thermostat of the heat recovery cells stops the TF supply air fan on the basis of the measuring data on the temperature sensor, thereby preventing the heat recovery cell from freezing. As soon as the risk of frosting passes, the fan restarts automatically. The threshold temperature for defrosting (-2 +6 C) and the difference area (2 C) can be set on the thermostat. Overheating Protection of the Heating Unit Overheat protection thermostats TZ and TZ2 monitor the surface temperature in the LP and LP2 heating units. If surface temperature exceeds the threshold, overheat protection is triggered and power supply to the heating unit is stopped. The TZ overheating protector is reset automatically, and the TZ2 protector manually. Damper Motors of the Outdoor and/or Extract Air Ducts The spring return damper motors (24VAC) that may be installed outside the ventilation unit, in the outdoor or extract air ducts, can be controlled with control voltage (24 VAC) coming from the ventilation unit: when the ventilation unit is stopped, also the control voltage fed from the unit is stopped. Alarms The PDS and PDS2 pressure difference switches monitor the pressure difference on the supply and discharge air sides. If the pressure difference grows too large because of dirty filters or clogged ducts, remote monitoring receives potential free operation mode information from the unit. Code Name Technical details Equip- Delivery (factory settings in parentheses) Note! ment Responsibility FG Damper motor Automatic heat recovery bypass 24V, 2W, 8Nm Standard X IU LP Preheater Electric radiator 2.5kW Options IU LP2 Post-heating unit Electric radiator 2.5kW Options IU LTO Heat recovery cells 2-step, = 70 % Standard X IU LTO2 PDS Pressure difference switch Adjustment range 0...500Pa (420) Pressure guard for supply air Options IU PDS2 Pressure difference switch Adjustment range 0...500Pa (420) Pressure guard for discharge air Options IU PF Discharge air fan qv = 230 dm3/s (00Pa) Standard X IU SU Filter Supply air EU7, discharge air EU5 Standard X IU TS Temperature thermostat Discharge air temperature Heat recovery defrosting Adjustment range -2...6 C (2) Standard X IU TS2 Temperature thermostat Supply air temperature Post-heating, electric Standard X IU TS5 Temperature thermostat Discharge air temperature Preheating, electric Adjustment range -0...8 C (2) Standard X IU TF Supply air fan qv = 20 dm 3 /s (00Pa) Standard X IU TZ Overheat protector of the electric radiator Automatic reset (+60 C) Included in LP / LP2 IU TZ2 Overheat protector of the electric radiator Manual reset (+95 C) Included in LP / LP2 IU FGU Damper motor Damper motor in the outdoor air duct (spring return) 24VAC IU FGJ Damper motor Damper motor in the extract air duct (spring return) 24VAC IU

CONTROL DIAGRAM VKL REMOTE MONITORING CONTROL Control Diagram VKL MANUAL CONTROL UNIT Distribution Panel Internal electrical and control connections Post-heating unit, water Pressure switch Pressure Preheating electric switch Sound attenuator REMOTE MONITORING CONTROL CENTER OF THE PROPERTY Alarm Operation mode Control Measurement Adjustment Ventilation zone 22

DESCRIPTION OF OPERATION VKL REMOTE MONITORING CONTROL UNIT Control of Operation If needed, the ventilation unit can be stopped by controlling the contactors in the unit (Min., /2, Max.) or by controlling power supply via the contactor in the distribution panel. Fan Speed Adjustment The ventilation unit can feed control voltage (24VAC) to the remote monitoring center, and the remote monitoring center can then direct the fan capacity of the ventilation unit in three steps according to the control signal (24VAC) received by the Min., /2, and Max. contacts in the connection box. Remote monitoring receives potential free operation mode information on the mode selected (Min., /2, Max.). Supply Air Temperature A regulating valve (not included in the VALLOX 252 delivery) directs the operation of the LP2 post-heating unit on the basis of the measurement data given by the thermostat sensor in the supply air duct. The aiming is to keep supply air temperature at the temperature value set with the regulating valve (0 25 C). Heat Recovery Bypass With the help of control voltage (24VAC) fed from the ventilation unit to the remote monitoring center and its control functions, the heat recovery bypass function can be directed according to the control signal (24 VAC) received by the NC contact in the connection box. When heat recovery bypass is activated, the preheater (LP), if used, and the post-heating unit (LP2) are deactivated. Parts List Heat Recovery Defrosting The TS5 temperature thermostat directs the operation of the preheater (LP) on the basis of the measurement data supplied by the temperature sensor, preventing the risk of freezing and the stopping of the supply air fan (TF). If the capacity of the preheater (LP) is not sufficient, or if there is no preheater, the TS defrosting thermostat of the heat recovery cells stops the TF supply air fan on the basis of the measuring data on the temperature sensor, thereby preventing the heat recovery cell from freezing. As soon as the risk of frosting passes, the fan restarts automatically. The threshold temperature for defrosting (-2 +6 C) and the difference area (2 C) can be set on the thermostat. Overheating Protection of the Heating Unit Overheat protection thermostats TZ and TZ2 monitor the surface temperature in the LP heating unit. If surface temperature exceeds the threshold, overheat protection is triggered and power supply to the heating unit is stopped. The TZ overheating protector is reset automatically, and the TZ2 protector manually. Damper Motors of the Outdoor and/or Extract Air Ducts The spring return damper motors (24VAC) that may be installed outside the ventilation unit, in the outdoor or extract air ducts, can be controlled with control voltage (24 VAC) coming from the ventilation unit: when the ventilation unit is stopped, also the control voltage fed from the unit is stopped. Alarms The PDS and PDS2 pressure difference switches monitor the pressure difference on the supply and discharge air sides. If the pressure difference grows too large because of dirty filters or clogged ducts, remote monitoring receives potential free operation mode information from the unit. Code Name Technical details Equip- Delivery (factory settings in parentheses) Note! ment Responsibility FG Damper motor Automatic heat recovery bypass 24V, 2W, 8Nm Standard X IU LP Preheater Electric radiator 2.5kW Options IU LP2 Post-heating unit Water radiator 5kW, 70/50oC Options IU LTO Heat recovery cells 2-step, = 70 % Standard X IU LTO2 PDS Pressure difference switch Adjustment range 0...500Pa (420) Options IU Pressure guard for supply air PDS2 Pressure difference switch Pressure guard for discharge air Adjustment range 0...500Pa (420) Options IU PF Discharge air fan qv = 230 dm 3 /s (00Pa) Standard X IU SU Filter Supply air EU7, discharge air EU5 Standard X IU SV Regulating valve Self-operating radiator thermostat Not included in the ventilation unit delivery TS Temperature thermostat Discharge air temperature Heat recovery defrosting Adjustment range -2...6 C (2) Standard X IU TS5 Temperature thermostat Discharge air temperature Preheating, electric Adjustment range -0...8 C (2) Standard X IU TF Supply air fan qv = 20 dm 3 /s (00Pa) Standard X IU TZ Overheat protector of the electric radiator Automatic reset (+60 C) Included in LP / LP2 IU TZ2 Overheat protector of the electric radiator Manual reset (+95 C) Included in LP / LP2 IU FGU Damper motor Damper motor in the outdoor air duct (spring return) 24VAC FGJ Damper motor Damper motor in the extract air duct (spring return) 24VAC IU IU 3

MOUNTING INSTRUCTIONS A (Door and insulation 55 mm) B C D 4 pcs Location of VALLOX The unit is mounted indoors, in a place where temperature does not fall below +0 C. The unit shall be mounted in a place where the sound pressure level coming through the envelope is not acoustically disturbing (storerooms, halls, utility rooms, and in some cases rooms where people spend a lot of time, such as classrooms). The unit is equipped with an adjustable socle. If the unit is mounted on a wall, keep in mind the weight of the unit (90kg) and vibration damping. The unit is splash-proof (IP34), so it can also be mounted in a damp room. IP L A = OUTDOOR AIR B = SUPPLY AIR C = DISCHARGE AIR D = EXTRACT AIR -R A = EXTRACT AIR B = DISCHARGE AIR C = SUPPLY AIR D = OUTDOOR AIR 2 3 4 4 3 Sleeves with draught-limiters (PK 6) Condensing water outlet Condensing water reservoir Socle Example of Pipe Connections VKL DN 5 2 Thermostat valve R/2" for radiator VALLOX Duct Connections The unit has four Ø 250 inner fittings equipped with rubber rings. The inner fittings can be detached and replaced with another type of fitting, such as bends. Fix the ducts steadily and tightly to the outlets. (Note! Aggregatets modeller L/R.) En eventuell isolering av kanalerna utförs enligt ventilationsplanen. VALLOX Condensing Water Connections The water condensing from discharge air going through the unit can be removed from the bottom tank in two ways. When discharge air humidity is great, as in the bathroom, the condensing water is led via the screw-type hose coupling and through the condensing water outlet (water seal and hose) delivered with the unit to the floor drain. When discharge air humidity is low, as in an office, condensing water can be led via the screw-type hose coupling to the condensing water reservoir delivered with the unit. The reservoir is placed under the bottom tank by pushing it to the rails on the socle. In this case, a separate condensing water outlet is not used. NOTE! If a condensing water reservoir is used, it must be inspected sufficiently often. As the screw-type hose coupling is located almost in the middle of the unit, the unit has to be located in a horizontal position. VALLOX Pipe Connections If the unit is equipped with a water post-heating unit, the unit has to be connected to the hot water circuit with copper tubes 5/3. The water circulation post-heating unit can be controlled with a thermostat valve R /2" equipped with a separate sensor. The valve is installed in the return water pipe, and the sensor in the supply duct outside VALLOX. Because of the risk of freezing in the heating unit, it is recommended to use a pipe connection as shown in the figure (A). NOTE! THE REGULATING VALVE IS NOT INCLUDED IN THE DELIVERY. VALLOX Pressure Difference Switches If the unit is equipped with pressure difference switches that monitor the pressure difference in the supply and / or discharge air ducts, their correct values have to be set after the ducts and the related air terminal devices (such as valves and grilles) have been mounted and adjusted. For further details, see the Instructions for using. Regulating valve Drainage Heating unit with water circulation Figure A 24

SOUND ATTENUATOR General The sound attenuator is a duct silencer that should be mounted on top of VALLOX 252 M. The attenuator includes a cover that can be opened, enabling the cleaning of the attenuator without detaching the ducts. The sound attenuator unit also features detachable attenuation segments in supply and discharge air ducts. 4 Ø 250 external fittings enable the laying of ducts straight from the unit by using bends etc. The top of the attenuator unit incorporates lead-in sealings for the lead-through tubes of cables and for the supply and return water pipes of a water heating unit, if one is used. The weight of the sound attenuator unit is 05kg including the door, and 82kg without the door. 5

MOUNTING INSTRUCTIONS FOR THE SOUND ATTENUATOR Mounting NOTE! BEFORE MOUNTING, CHECK THE MODEL OF (L or R). Detach the door of the sound attenuator. (See the adjoining picture.) Detach the sleeves equipped with draught limiters (see the figure, item D). Cut through the lead-in sealings for the cable sleeves at the bottom of the extract duct of the sound attenuator unit (no isolation inside). NOTE! VALLOX 252 model L or R. (See the figure.) If VALLOX 252 is equipped with a water heating unit, also detach the sound attenuation segment located in the supply air duct of the unit. NOTE! VALLOX 252 model L or R. (See the figure.) Lift the sound attenuator unit on top of VALLOX 252. Make sure that the cable sleeves go through. (See the figure, item D.) Mount the lead-through cable tubes (included in the delivery), pushing them through the lead-in sealings on top of the sound attenuator unit, and screwing them to the cable sleeves. (See the figure, item C.) Lay the cables to be connected through the lead-through tubes to the connection box inside VALLOX 252. If a water heating unit is used, lead the supply and return pipes (not included in the delivery) of the heating unit through the lead-in sealings on top of the sound attenuator unit and VALLOX 252, and connect them to the supply and return water outlets with a straight fitting, for instance. (See the figure, items A and B.) Mount the sound attenuation segment in place. Carefully fix the door of the sound attenuator in place. Fix the ducts steadily and tightly to the outlets. If ducts are to be isolated, do so following the ventilation plan. Supply and return water pipe Ø5/3 2 pcs Straight fitting MS5 2 pcs Supply and return water pipe Ø5/3 2 pcs Lead-in sealings for supply and return water pipes 2 pcs Sound attenuator unit (Note! Vallox model) Duct fitting Ø250 4 pcs Lead-through tubes for cables 3 pcs Supply and return water outlet 2 pcs Sound attenuation segment Lead-in sealing for cable lead-through tube 3 pcs Lead-in sealing for cable sleeve 3 pcs (bottom) Lead-through tubes for cables 3 pcs VALLOX 250 L (Note! model) Sleeve equipped with draught-limiter 3 pcs Cable sleeve 3 pcs 26

MOUNTING INSTRUCTIONS VALLOXs Electrical Connections The unit is connected permanently to the electrical power network. The connection box is located inside the unit, next to the extract air duct outlet. The cables to be connected are led to the unit through the sleeves with draughtlimiters and the cable sleeves located beside the extract air duct outlet. Mounting Detach the upper door of the unit (screw M8x70, 5 pcs). Detach the cover of the connection box (screw 3.5x9.5, 2 pcs). Mount and fasten the cables needed to the terminal block following the connection instructions. The external wiring diagram is included in these instructions, and it is also found inside the cover of the connection box. The internal wiring diagram is included in these instructions, and it is also found on the cover of the fuse box inside the unit. Installation of the Manual Control Unit The control panel that comes with the unit is in a surface mounting case. The manual control unit can also be flush mounted in a double gang box (U 7.2 ENSTO). The manual control unit cannot be used in connection with remote monitoring control. Connection to Remote Monitoring The ventilation unit is connected to remote monitoring according to the wiring diagrams attached. ONLY AN AUTHORIZED PERSON MAY PERFORM ELECTRICAL CONNECTIONS! BEFORE CONNECTING THE CABLES, MAKE SURE THAT THEY HAVE BEEN DISCONNECTED FROM THE MAINS SUPPLY! OUTDOOR AIR TO THE UNIT SUPPLY WATER TO THE RADIATOR RETURN WATER FROM THE RADIATOR -L SUPPLY AIR FROM THE UNIT DISCHARGE AIR TO THE UNIT CONNECTION CABLE Remote monitoring Manual control CONNECTION CABLE Duct damper motor FEEDER CABLE Distribution panel EXTRACT AIR GOING OUT ELECTRICAL CONNECETIONS The manual control unit cannot be used in connection with remote monitoring control. Selection of Control Voltages for Capacity Modes (Min., /2 and Max.) BEFORE SELECTING CONTROL VOLTAGES, MAKE SURE THAT THE UNIT HAS BEEN DISCONNECTED FROM THE MAINS SUPPLY! If needed, the factory settings for adjusting fan capacity modes (Min., /2 and Max.) can be modified. The factory setting for the Min. mode control voltage is 90V. You can modify the control voltage by moving the conductor between contact 3 of the K2 contactor and the transformer to the desired voltage (00V, 0V, 30V, 40V, 60V, 200V, and 230V). Manual control unit The factory setting for the /2 mode control voltage is 40V. You can change the control voltage by moving the conductor between contact 4 of the K3 contactor and the transformer to the desired voltage (90V, 00V, 0V, 30V, 60V, 200V, and 230V). The factory setting for the Max. mode control voltage is 230V. You can change the control voltage by moving the conductor between contact 3 of the K contactor and the transformer to the desired voltage (90V, 00V, 0V, 30V, 40V, 60V, and 200V). 7

INTERNAL WIRING DIAGRAM TF = Supply air fan 2x230W PF = Discharge air fan 2x230W C = Capacitor 6mF FG = Damper motor TR = Transformer 230V 4A/24V 25VA TS = Defrosting thermostat for heat recovery cells + 2oC (adjustable) TS2 = Thermostat for post-heating unit +5oC...25oC TS5 = Thermostat for preheater +4oC (adjustable) K = Contactor max. speed K2 = Contactor min. speed K3 = Contactor /2 speed K4 = Contactor, disconnection of the heating units for heat recovery bypass S = Service switch (door switch) LP = Preheater 2,500W (optional) LP2 = Post-heating unit 2,500W (optional) TZ = Overheating protector +60oC TZ2 = Overheating protector +95oC (manual reset) PDS = Supply air duct pressure difference switch (optional) PDS2 = Discharge air duct pressure difference switch (optional) F = Fuse 4A F2 = Fuse.6A 28

EXTERNAL ELECTRICAL CONNECTIONS - MANUAL CONTROL DISTRIBUTION PANEL POS. 2 STATUS POS. MAX. /2 MIN. STATUS NC 24VAC MAX. /2 MIN. N / 24VAC L0 L L N - NOTE! When the unit is equipped with a PREHEATER and an ELECTRIC POST-HEATING UNIT, a separate 6A power supply is needed for THE PREHEATER. 5x0.5 ÖPVC-OZ OR SIMILAR NOTE! When the unit is equipped with a PREHEATER and a POST-HEATING UNIT WITH WATER CIRCULATION, the L and L on the terminal block are connected.. In this case, THE PREHEATER DOES NOT NEED a separate power supply. SUMMER WINTER CAM SWITCH DAMPER MOTOR 24VAC FOR OUTDOOR OR EXTRACT AIR DUCT MANUAL CONTROL UNIT 9

EXTERNAL ELECTRICAL CONNECTIONS VALLOX 252 REMOTER MONITORING CONTROL External Electrical Fan capacity control Control voltage 24VAC for the Min. mode Control voltage 24VAC for the /2 mode Control voltage 24VAC for the Max. mode Control voltage 24VAC for remote monitoring Heat recovery bypass control Heat recovery active = 24VAC Heat recovery deactivated = 0VAC Operation mode information on fan capacity modes Entering operation mode information on capacity modes Operation mode information on the Min. mode Operation mode information on the /2 mode Operation mode information on the Max. mode Operation mode information from the pressure difference switch Operation mode information from Pos. (discharge air duct) Entering operation mode information for Pos. and Pos. 2 Operation mode information from Pos. 2 (discharge air duct) REMOTE MONITORING 2x0.5 ÖPVC-OZ OR SIMILAR NOTE! When the unit is equipped with a PREHEATER and an ELECTRIC POST-HEATING UNIT, a separate 6A power supply is needed for THE PREHEATER. DISTRIBUTION PANEL POS. 2 STATUS POS. MAX. /2 MIN. STATUS NC 24VAC MAX. /2 MIN. N / 24VAC L0 L L N - NOTE! When the unit is equipped with a PREHEATER and a POST-HEATING UNIT WITH WATER CIRCULATION, the L and L on the terminal block are connected. In this case, THE PREHEATER DOES NOT NEED a separate power supply. DAMPER MOTOR 24VAC FOR OUTDOOR OR EXTRACT AIR DUCT Vallox Oy FIN-32200 Loimaa Finland Tel: +358 2 7636 300 Fax: +358 2 763 539 Internet: www.vallox.com.09.85e/3.0/pdf