PRODUCT DATA COMFORT 1200 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 1400 m 3 /h

Similar documents
PRODUCT DATA COMFORT 5000 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 5300 m 3 /h

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

PRODUCT DATA COMFORT 600 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 800 m 3 /h

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

PRODUCT DATA COMBI 300 POLAR BY NILAN. Ventilation with passive & active heat recovery. Active heat recovery. Passive heat recovery.

PRODUCT DATA COMFORT 300 TOP BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 325 m 3 /h

PRODUCT DATA VPL 15 TOP M2 BY NILAN. Ventilation & active heat recovery. Active heat recovery. Comfort heating. Comfort cooling.

PRODUCT DATA VPL 28 BY NILAN. Ventilation & active heat recovery. Active heat recovery. Comfort heating. Comfort cooling.

PRODUCT DATA COMPACT S BY NILAN. Sanitary hot water production. Passive heat recovery. Comfort heating. Ventilation < 375 m 3 /h. Active heat recovery

PRODUCT DATA COMFORT 302 TOP BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 345 m 3 /h

PRODUCT DATA VP 18 BY NILAN. Sanitary hot water production. Heating. Active heat recovery. Comfort heating. Ventilation < 300 m 3 /h.

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

Comfortable indoor climate regardless of the season

VENTILATION = WELL-BEING

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

Installation Instruction

eco PREMIUM ENERGY RECOVERY UNIT» Technical instruction

VEX100 series Air handling units with cross-flow heat exchanger

Air Handling Unit. REC Temovex Blue 4 NEW! Experts on indoor climate in low-energy houses

Technical specifications

AIR HANDLING UNITS RIS P EKO 3.0. New range - 5 sizes, 20 models! Efficient EC. E f f i c i e n c y up to 94%! E x t r e m e l y low height! fans!

Air handling unit. REC Temovex 400S-EC-RS. Experts on indoor climate in low-energy houses

User manual. CTS 602 by Nilan VPL 15 VPL 15 TOP. Version: 9.02, Software-version: 2.21

Operation and maintenance instructions

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

39HX. High-efficiency dual-flow air handling unit PRODUCT SELECTION DATA. Plug & play unit (built-in control) Class A+ across entire range

panel filters with filtering class G4. Supply filter F7 can be supplied with the few models.

Swegon CASA W130. Ventilation unit with counter-flow plate heat exchanger HOME VENTILATION

PRODUCT DATA COMPACT P RANGE BY NILAN. Heating. Sanitary hot water production. Ventilation < 300 m 3 /h. Passive heat recovery.

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

User's Guide. CTS6000 control panel

Fresh air unit ALB. ALB it s simple and so easy! Air supplied through a heater and filter in a single unit.

GLOBAL LP. Ceiling-mounted ventilation unit with plate heat exchanger

Energy-efficient heat source provides comfort in large rooms

TSEK VHR EC HEAT RECOVERY UNITS

USER MANUAL CTS700 TOUCH BY NILAN. Compact P / Compact P Polar (English)

The new Xcell EC High Efficiency Range Fresh air pure and simple

panel filters with filtering class G4. Supply filter F7 can be supplied with the few models.

User manual. User manual. CTS 600 by Nilan. Comfort Comfort Version: 10.00, Software-version: 2.30

TECHNICAL INFORMATION HCV 4 - HCV 5 - HCH 5 - HCH 8 Demand-controlled home ventilation

CONTENT: VEX308 Decentralised ventilation VEX308

Zehnder ComfoAir 550. Ventilation unit

TopVent Design Handbook

FLOWAY. Floway Range. The dual-flow air handling unit with heat recovery guaranteeing an Economical and Durable solution. use.

Installation instruction

MAXI CENTRALIZED VENTILATION WITH HEAT RECOVERY

TopMaster Air Handling unit. Technical data

Small Room Heat Recovery Ventilation

CLIMASTER ZCF AIR HANDLING UNITS

Series VUT PW EC. wool internal heat and sound-insulating layer for VUT PE/PW 350, 600, 1000 units and 50 mm for VUT PE/PW 200, 3000 units.

Technical Information HCV - HCH Demand-controlled home ventilation

CONTENT: VEX300C Ceiling units VEX320C/330C

Lo-Carbon Sentinel Kinetic Horizontal

KOMFORT EC DB Suspended heat recovery air handling units

VERSO Air Handling Units

Series. Suspended air supply units with the air capacity up to 4100 m 3 /h in the sound- and heat-insulated casing with the water heater

Technical Information HXV - HRV Ventilation

Series VENTS VUT R WH ЕС

VERSO Air Handling Units

MRXBOXAB-ECO-LP1 100% Typical Installation. (including opposite handed versions)

VEX350 / VEX360 Air handling units with counter flow heat exchangers

VEX250H with rotary heat exchanger and EXact control system

AHU N : Range: VERSO VERSO. Heat Recovery Air Handling Units. Plug & Play Energy Saving Smart Design Reliable & Safe

CTS 602 by Nilan. Compact P. Compact P Sun. Compact P Cool. Compact P Cool Sun. Version: 5.00, Software-version: 2.11

VERSO DOMEKT. Residential ventilation units m³/h. Non residential ventilation units m³/h

Silencer Preheater unit Electric post-heating unit Water circulated post-heating unit CO 2 sensor %RH sensor Pressure difference switch LON converter

VEX280H with rotary heat exchanger and EXact control system

Heat and energy recovery ventilators

IN LINE MIXED FLOW DUCT FANS AND ELECTRIC HEATER TD-MIXVENT HEATING System

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

UNITES TERMINALES ET MINI CTA FIDJI

GHE GHE. Dehumidifiers for radiant cooling systems with heat recovery VERSIONS ACCESSORIES

Homepage > Products > Decentralised ventilation systems > Vertical units > Type FSL-V-ZAB/SEK FSL-V-ZAB/SEK

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

Adconair 76. Comfort air conditioning unit with counterflow plate heat exchanger. AIR VOLUME FLOW: 2,600 23,600 m³/h

MRXBOXAB-ECO4 100% and Opposite Handed version. Typical Installation

Adsolair 56/58. Comfort air conditioning unit with double plate heat exchanger and adiabatic evaporative cooling system

Installation instruction

Sentinel Demand Energy Recovery Ventilation

TopMaster Air Handling Unit

RIS V EKO A1/L2 RIS 700 V E L EKO 3.0 AIR HANDLING UNITS. Application

EC L2. and humidity sensors. All units are supplied tested and ready to install.

Eco Active H E A T R E C O V E R Y S Y S T E M S. Heat Recovery Penthouse Turret. W: T:

MRXBOXAB-ECO3 MRXBOX-ECO3

HEAT RECOVERY VENTILATION UNIT DESCRIPTION. FANS s Plug fans. s Direct drive continuous current motors with electronic switching

MRXBOXAB-ECO2 MRXBOX-ECO2

User Manual. Vanvex Optima 180 Domestic Hot Water. Version

Technical manual MARK WTW AIRSTREAM _R01

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CI/SfB (57.5) November 2008

PRODUCT DATA NILAIR BY NILAN. Air distribution. Domestic. Ventilation

RoofVent Design Handbook

Swegon CASA R120. Ventilation unit with rotary heat exchanger HOME VENTILATION

Technical Information. Ventilation

Heat recovery unit RDKS

Heat Recovery Unit HERU. web-version

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

MRXBOX90 - WHOLE HOUSE HEAT RECOVERY UNIT

Heat Recovery Units. Heat Recovery 1

290 on. 286 on. Comfortable climate with pre-heated, filtered supply air. Fresh air boxes ALB WW MODEL WITH WARM WATER HEATING

Transcription:

PRODUCT DATA COMFORT 00 BY NILAN Ventilation & passive heat recovery Commercial Passive heat recovery Ventilation < 00 m /h

COMFORT 00 The Comfort 00 is a ventilation unit suitable for central ventilation of residential buildings, schools, offices and business facilities with a ventilation requirement of up to 00 m /h. Every component has been carefully selected with a view to unsurpassed quality and each component is tested throughout the entire production process, as are the finished units before leaving the factory. This quality control reflects our high standards, which not only exceed market requirements but also take them several steps further. Modulating bypass An automatic bypass valve directs the fresh air past the heat exchanger when waste heat recovery is not necessary, thus conserving energy. Automatic control The Comfort 00 is supplied with an integrated CTS 0 control, which is operated by the enclosed control panel. The modern CTS 0 control communicates Modbus RTU RS8. A CTS system using this type of communication can easily be connected to the device. Filters The Comfort 00 is supplied with bag filters. An M filter in the air exhaust and an F7 filter for fresh air are supplied as standard. The CTS 0 control has a built-in timer controlled alarm for change of filter. It is possible to install a pressure controlled filter monitor (accessorie). Doors The large doors allow easy access for the changing the filters, as well as for servicing of the unit. Frost protection An electric heater can be purchased for frost protection. This prevents the formation of ice in the counterflow heat exchanger in the event of long periods of frost.

COMFORT 00 BY NILAN Counterflow heat exchanger Heat recovery is achieved by two counter flow heat exchangers made of highly corrosion resistant marine aluminium. The counterflow heat exchangers have an energy efficiency of more than 80% and prevent odours being transferred from the extracted air to the supply air. The CTS 0 control allows for cooling recovery. Plug fans The two fan sections consist of energy-efficient EC motors with built-in motor controllers operated by a 0-0V signal. The efficient fan wheels haverear facing impellers and are extremely quiet. Construction The Comfort 00 is housed in a strong frame structure of Aluzinc with 0 mm insulation. Base The Comfort 00 is delivered with a robust, built-in base. Heating elements External water or electric heating elements, regulated by the CTS 0 control, can be purchased. Pressure control The extraction and/or supply fan can be operated with the aid of a pressure transmitter. The water-heating surface can be built into the unit.

COMFORT 00 Technical specifications Dimensions (W x D x H) Weight 8 x 8 x 970 mm 0 kg Min. Airvolume 00 m /h Max. Airvolume 00 m /h Power consumption Power supply Max. phase Standby power Plate type casing Heat exchanger type Filter class Duct connections Condensate drain 00W 0 V (±0 %), 0/0 HZ A W Aluzinc steel plate Aluminium counterflow heat exchanger Standard bagfilters M Extract air and F7 Fresh air Ø mm PVC, Ø 0. mm External leakage underpressure (*) <. % External leakage overpressure (*) <. % Internal leakage (*) <.90 % Tightness class IP * At ± 0 Pa and 00 m /h according EN 08/EN -7. * At ± 00 Pa and 00 m /h according EN 08/EN -7. * At ± 00 Pa and 00 m /h according EN 08/EN -7. Motor and motor control Motor type Motor class in accordance with IEC 00-0 Voltage input Current overload protection Control signal with third party control system EC-Engine IE (Premium efficiency) x 0 V Built-in 0-0 V DC Fluid temperature (air) -0 / 0 C Ambient temperature (operating) -0 / 0 C

COMFORT 00 BY NILAN Functional diagram T TC T9 T/T7 T7 T0 T8 T Connections : Fresh air : Supply air : Extract air : Discharge air : Condensate drain : Electric and water heating Automation T/T7: Supply air sensor T9/TC: Heating element frost protection T: Extract air sensor T: Discharge air and defrost sensor T8: Fresh air sensor T0: Room sensor

PLANNING DATA Nilan units are tested in accordance with the valid standards of accredited independent test institutes. Capacity Capacity of standard unit as a function of q v and P t, ext. SFP values according to EN -7 are for standard units with M-filter in extract air, F7-filter in fresh air and no heating element. SFP values comprise the unit s total power comsumption incl. control. Conversion factor: J/m = W/m /h 00 P t ext [Pa] 00 00 00 00 00 J/m 800 J/m 00 00 J/m 00 000 J/m 0 00 00 00 800 000 00 00 00 800 000 00 0 00 0 00 0 00 0 00 q v [m /h] q v [l/s]

COMFORT 00 BY NILAN Temperature efficiency Temperature efficiency for unit with counterflow heat exchanger according to EN08 (dry). Temperature efficiency EN08: ɳ t = (t supply air-t fresh air)/(t extract air-t fresh air) η t (%) 00 9 90 8 80 7 70 0 00 00 00 800 000 00 00 00 800 000 0 00 0 00 0 00 0 00 0 00 q v [m /h] q v [l/s] Sound data Sound data for q V = 00 m /h and P t, ext = 0 Pa according to EN 9- for surfaces and EN for ducts. Sound output level L WA drops with falling air volume and falling back pressure. Sound output level L pa at a given distance will depend on acoustic conditions in the place of installation. Sound output level (L WA ) Oktavband Hz Surface db(a) Supply air db(a) Extract air db(a) Fresh air db(a) Discharge air db(a) 8 8 9 7 8 0 9 8 00 9 0 7.000 7 7.000 7 7 0 7.000 8 7 7 9 Total ± db(a) 77 7 9 77 7

CN CN CN CN CN 7 8 9 0 7 8 CN 7 8 9 0 CN CN CN CN CN 7 8 9 0 7 8 CN 7 8 9 0 CN7 CN7 CN0 RS RS R R R R R7 R8 CN8 CN9 CN0 CN CN CN7 CN R9 R0 R R CN CN7 CN0 RS RS R R R R R7 R8 R9 R0 R R CN8 CN9 CN0 CN CN CN CN PLANNING DATA Heating elements (accessory) Water heating element (for internal fitting) Entreprenøren skal sørge for frostsikring af rørinstallationen Mixer Forslag circuit til blandekreds proposal 70 C 0 C CTS Brugerpanel CTS C C P P=0kPa Safety Sikkerhedsafbryder switch ESC ENTER OFF ON T The operating panel must be placed in a dry, frost-free location. Y Power Strømforsyning supply N 0V 0Hz max. xa T0 (accessory) can be mounted in a extraction valve or duct max. m C M C Switch Kontakt for for brugervalg user choise (Tilbehør) (accessory) B B T/T7 Extract air T0 IF T CTS B T9 Supply air Fresh air T8 T Discharge air UF T/T7: Supply air sensor T9: Heating element frost protection T: Extract air sensor T: Discharge air and defrost sensor T8: Fresh air sensor T0: Room sensor Electrical heating element (duct mounted) CTS Brugerpanel CTS The operating panel must be placed in a dry, frost-free location. ESC ENTER OFF ON T Strømforsyning N Power 0V 0Hz supply max. xa Safety Sikkerhedsafbryder switch Power supply Strømforsyning T0 (accessory) can be mounted in a extraction valve or duct Switch Kontakt for for brugervalg user (Tilbehør) choise (accessory) B B T/T7 Extract air T0 IF T CTS 0, m m T7 Supply air Fresh air T8 T Discharge air UF 8

COMFORT 00 BY NILAN Capacity - Heating element (accessory) Electrical heating surface The electrical heating surface is fitted in the air inlet duct at a distance of min. x duct diameter from the system s fresh air inlet connection pipe (normally min 00 mm.) and connected to the CTS 0 control panel and x 00 V supply. The electrical heating surface can supply up to kw of heat. Water heating element for internal fitting The water heating element is designed to be built into the system and must be connected to the primary heating supply and the CTS 0 control. The water heating element includes copper pipes and aluminium fins. Capacities can be seen in the table below. Capacity water heating element Water side Air side Temperature input/output [ C] Flow [l/h] Pressure drop [kpa] Output [kw] Flow [m /h] Temperature before WHE* [ C] Temperature after WHE* [ C] Pressure drop over WHE* [Pa]..8 00 9.. 0.. 00 7.7 8. 0/0 9..9 800..0 8.. 000.7 8.7 9 8.0.7 00.0. 0 9.. 00...8. 00 0.0. 88.9. 00 7. 8. 0/0.. 800..0 0..0 000. 8.7 90..7 00.. 8 7. 7. 00.. 07.0.7 00.9. 0.7.8 00 9. 8. 70/0 8..8 800 7..0 9.0. 000. 8.7. 7. 00.0.. 8. 00.9. * Water heating element. 9

AUTOMATION CTS0 Control The Comfort 00 is controlled using its CTS 0 operating panel, featuring a wide range of functions, e.g., menu-controlled operation, weekly programme settings, filter monitor with timer, fan speed adjustment, summer bypass (free cooling), post-heating element control, error messages etc. The CTS 0 comes with factory settings, including a default setting which can be customised to operational requirements to achieve optimum operation and utilisation of the system. The operating panel must be placed in a dry, frost-free location, at least. m above floor level and at least 0. m from any corner. Avoid placing the panel on an external wall or in areas in direct sunlight. Operating instructions for the CTS 0 can be found in a separate user manual supplied with the unit. External communication The CTS 0 control unit communicates by default with Modbus RTU RS8 communication. A CTS system using this form of communication can easily be connected to the unit. Nilan units have an open Modbus communication, i.e. not only can the unit be monitored, but its operation can also be set in the same way as it can via the operating panel. CTS / Computer Konverter Modbus The protocol is set up by default for a Modbus RTU 0 address, but can be set to a value between and 7. A Modbus converter allows you to connect one or more units to a computer to monitor and control the unit. 0

COMFORT 00 BY NILAN Functional overview Standard - Accessories levels The control function is divided into levels: User/Service/Factory with various options at each level Weekly plan There is an option for you to set your own weekly programme. User option This allows you to override the operating mode in the main menu via an external potential-free contact or PIR sensor. Alarms Alarm log featuring the last alarms. Filter monitor Filter monitor with timer (factory setting of 90 days). Adjustable to 0/90/80/0 days. Pressure controlled filter monitor Bypass It is possible to purchase Comfort 00 with a pressure controlled filter monitor - Bypassing the outdoor air reduces heat recovery, enabling the desired supply air temperature to be maintained spring, summer and autumn. Air quality Allows you to choose whether to switch humidity sensors and/or CO sensors on and off. - Humidity control Allows you to set a higher or lower ventilation step in the case of high/low air humidity. - CO control Allows you to set a higher or lower ventilation step in the case of a high/low CO level. - Air exchange Allows you to select a low ventilation step in the case of low outside temperatures and air humidity. Defrost function Temperature-based automatic function for defrosting the heat exchanger. Frostprotection Temperature control Room low In case of failing heating system, the unit is turned off to avoid further cooling with a risk of the water heating coil frost bursting. Allows you to select the temperature sensor which will control the unit. T ROOM (panel sensor) T0 EXT (fitted in a representative extraction valve) T EXTRACT (extract air) Stops the unit at a low room temperature. Hereby is cooling of the home avoided in case of a failing central heating system. Standard set to OFF. Can be set from to 0 degrees and is controlled by: T ROOM (panel sensor) T0 EXT (fitted in a representative extraction valve) T EXHAUST (extract air) Room control Allows you to set the regulator to control the room temperature. Air volume Fire alarm Allows you to set four ventilation steps. Supply air and extract air are set individually. Step < % - Step < % - Step < 70% - Step < 00% This allows you to connect fire-detecting thermostats, smoke detectors and other fire alarm contacts. In case of an alarm, smoke dampers are closed and the unit stops. Joint alarm Outlet for joint alarm Constant pressure control Allows control from both the extract air and supply air side. - Cooling Intake air control External heating element External electric heating element Via bypass. This allows you to choose whether to run the system at a higher or the highest ventilation step during cooling. The weekly programme has an option for setting cooling at night. Allows you to set the regulator to control the intake air temperature/supply air (only available if the control unit has been configured for a supply-heating element). Temperature sensor T7 is an supply air sensor Integrated frost protection for external water heating element Motorised valve and circulation pump control unit Temperature sensor T7 is an supply air sensor Overheating protection Delayed start-up There is a possibility for a delayed start-up by the fans, when a closing damper is installed. Expansion PCB Allows you to make additional connections, e.g. User option overrides User option (e.g. connecting an EM box) Up to 00 W direct Can give the signal for external heating if the defrost function is used Switching the central heating system on/off Reset Allows you to restore the factory settings. Manual test Allows you to test the unit s functions manually. Language Option for setting the relevant language (Danish/Finnish/Norwegian/Swedish/German/English/ French). /- - - -

OPERATION Frost protection All ventilation units with a counterflow heat exchanger will ice up if the outdoor temperature is below freezing for a prolonged period. ɳt[%] With pre-heater The extracted air condenses when it is cooled down during heat recovery. The high temperature efficiency will slowly turn the condensate to ice, which will block up the counterflow heat exchanger unless action is taken to remedy this. Consideration must be given to whether the unit s operation can be protected during a lengthy period of frost or whether it is acceptable to decrease its operation. Temperature efficiency Operation Ice building Defrost Ice building Defrost function Defrost t Außen > - C t Außen < - C In homes which are occupied at night, it would be advisable to protect the unit against frost when the outdoor temperature is coldest by using a pre-heating element. On the other hand, if the ventilation is for an office, it may be acceptable to decrease the operating level at night. The energy used for the preheating is not wasted, as it ensures a constant high temperature efficiency Frost protection Normal operation No Outdoor temperature < - C After 0 min. Yes Yes Pre-heater installed No Normal operation secured until outdoor temp. < - C Defrost function starts when: Outdoor temp < C (T8) Discharge air < C in min. When outdoor temp. < - C reduced air volume Eftervarmeflade monteret Ja Nej. The heating element goes up in operation. The bypass damper is opened and leads the outdoor air past the heat exchanger. Warm exhaust air is blown through the heat exchanger. The ice melts. Bypass damper opens. The intake motor switches off. Warm extracted air will flow through the heat exchanger. The ice is melting Defrosting stops when: Discharge air > 7 C (T)

DIMENSIONAL DRAWING COMFORT 00 BY NILAN Right model Fresh air Discharge air 00 00 0 97 970 97 8 Ø 00 0, 90 8 87 Condensation drain 00,, 90 00 97 970 87 97 Supply air 970 Extract air

ACCESSORIES Top cover If Comfort 00 is going to be installed outside, it is possible to order a top cover which protects the unit against rain and snow. Pressure transmitter The extraction and/or supply fan can be operated with the aid of one or two pressure transmitters. Water heating element incl. regulation The supply temperature can always be raised to the required level using a water heating element. The water heating element is designed to be built into the unit and must be connected to the primary heating supply. Supplied with two-way adjustment valve, temperature sensor and frost thermostat. Electrical heating surface incl. regulation When you fit an electrical heating surface, you can raise the fresh air temperature to the desired level at any time. The electrical heating surface is supplied ready to fit into the fresh air duct and, for easy fitting, the device is pre-fitted with all the required sensors. Electrical pre-heating element (Frost protection) An electrical pre-heating element heats up the outdoor air before it enters the unit. This avoids having to defrost the unit, resulting in a loss of power. There are temperature sensors supplied to be fitted in the ducts. Expansion PCB The expansion PCB provides additional functions for the CTS 0 control unit, e.g., controlling the EM-box (see list of functions on page 7). Installationset Vibration absorbers and a water trap for the condensation outlet. Heating cable To protect the condensation outlet against frost, a metre-long self-regulating heating cable can be ordered.

DELIVERY AND HANDLING COMFORT 00 BY NILAN Transport and storage Comfort 00 comes in factory packaging that protects it during transport and storage. Comfort 00 must be stored in a dry place in its original packaging until installation. The packaging should only be removed immediately prior to installation. Installation conditions 87 During installation, future service and maintenance should be taken into account. We recommend a minimum gap in front of and behind the unit of 9 cm. The unit must be installed level for the sake of the condensate drain. The condensate drain requires clearance of min., cm under the drain nozzle. 8 Service clearance (unit shown from above) 90 Installation of electric heating element Electric heating elements (accessories) are fitted in the duct. The fitter should ensure that there is a safe distance of at least cm between the electric heating element and any inflammable material. The heating element must be insulated using fire-resistant insulation material. The electric heating element must be connected by an authorised electrician. Min. cm Electric pre-heating element with temperature sensor Electric heating element Min. cm Min. cm

00 0 87 INFORMATION FROM A TO Z Nilan develops and manufactures premium-quality, energy-saving ventilation and heat pump solutions that provide a healthy indoor climate and low-level energy consumption with the greatest consideration for the environment. In order to facilitate each step in the construction process from choosing the solution through to planning, installation and maintenance we have created a series of information material which is available for download at www.nilan.dk. Brochure General information about the solution and its benefits. Product data Technical information to ensure correct choice of solution. WWW.NILAN.DK Nilan A/S Nilanvej 87 Hedensted Danmark Tlf. 7 7 00 Fax 7 7 nilan@nilan.dk www.nilan.dk Installation instructions Detailed guide for installation and initial adjustment of the solution. Visit us at www.nilan.dk to find out User manual Detailed guide for regulation of the solution to ensure optimum day-to-day operation. more about our company and solutions, download further information and find your nearest dealer. Drawings Tender documents and D drawings are available to download for planning purposes. 8 90 970 00 Ver..0-07.09 Nilan A/S assumes no responsibility for any errors or omissions in the printed information material or for loss or damage that may follow from the use of such published materials - whether such loss of damage is caused by errors or inexpediencies in the material or otherwise. Nilan A/S reserves the right without prior notice to change products and information material. All trademarks are the property of Nilan A/S. All rights reserved.