Heat recovery unit RDKS

Similar documents
TopMaster Air Handling unit. Technical data

Swegon CASA R120. Ventilation unit with rotary heat exchanger HOME VENTILATION

HEAT RECOVERY UNIT MINIMASTER RDKS INSTALLATION, OPERATION, MAINTENANCE AND SPARE PARTS

eco PREMIUM ENERGY RECOVERY UNIT» Technical instruction

MAXI CENTRALIZED VENTILATION WITH HEAT RECOVERY

for a considerable reduction of the supply air temperature which, in turn, reduces the air conditioning

KOMFORT EC DB Suspended heat recovery air handling units

FRESHBOX 100. Single-room heat recovery unit. Air flow up to 59 CFM Heat recovery efficiency up to 96 %

AIR HEATING UNIT HEATMASTER ACJB INSTALLATION, OPERATION, MAINTENANCE AND SPARE PARTS

KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S. Heat and Energy Recovery Ventilators

Heat recovery unit RDKS. Technical instructions for installation, operation and maintenance

Swegon CASA W130. Ventilation unit with counter-flow plate heat exchanger HOME VENTILATION

ROOFMASTER STEF-HT ROOF FAN

Series VENTS VUT R WH ЕС

HOTEL CHILLED BEAM IQ STAR SILENCIA

CPD COOKER HOOD TECHNICAL DATA

Swegon CASA R85. Ventilation unit with rotary heat exchanger HOME VENTILATION

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

Air handling unit. REC Temovex 400S-EC-RS. Experts on indoor climate in low-energy houses

Air Handling Unit. REC Temovex Blue 4 NEW! Experts on indoor climate in low-energy houses

HEAT RECOVERY UNIT VILLAMASTER RDAF INSTALLATION, OPERATION, MAINTENANCE AND SPARE PARTS

FRESHBOX 100. Single-room heat recovery unit. Air capacity up to 100 m³/h Heat recovery efficiency up to 96 %

MRXBOXAB-ECO-LP1 100% Typical Installation. (including opposite handed versions)

TECHNICAL SPECIFICATION

Unit heater with accessories

PRODUCT DATA COMFORT 5000 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 5300 m 3 /h

TECHNICAL SPECIFICATION

66 on. Central ventilation system ZLS-DV EC according to DIN Central ventilation system ZLS EXTRACT AIR FIRE PROTECTION OUTSIDE AIR

PRODUCT DATA COMFORT 302 TOP BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 345 m 3 /h

PRODUCT DATA COMBI 300 POLAR BY NILAN. Ventilation with passive & active heat recovery. Active heat recovery. Passive heat recovery.

Zehnder ComfoAir 550. Ventilation unit

PRODUCT DATA COMFORT 600 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 800 m 3 /h

MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR) NEW ECO RANGE

iq Star LYRA II chilled beam cassette

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

VIESMANN VITOVENT 300-F Mechanical ventilation system with heat recovery

TopMaster Air Handling unit. Installation instructions

Flexit air handling units C2 and UNI 2, 3,4

Series. Suspended air supply units with the air capacity up to 4100 m 3 /h in the sound- and heat-insulated casing with the water heater

AIR HANDLING UNITS ASSET REFERENCE: DESIGN AHU 1 AHU 2

VENTS VUT R TN H ЕС VENTS VUT R TN EH ЕС

Series VUT PW EC. wool internal heat and sound-insulating layer for VUT PE/PW 350, 600, 1000 units and 50 mm for VUT PE/PW 200, 3000 units.

Contents. Technical Description of the Air Handling Unit General, Specification Function, Functional Sections

MRXBOXAB-ECO4 100% and Opposite Handed version. Typical Installation

panel filters with filtering class G4. Supply filter F7 can be supplied with the few models.

MRXBOXAB-ECO3 MRXBOX-ECO3

FLOWAY. Floway Range. The dual-flow air handling unit with heat recovery guaranteeing an Economical and Durable solution. use.

MRXBOXAB-ECO2 MRXBOX-ECO2

PRODUCT DATA COMFORT 300 TOP BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 325 m 3 /h

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

Flexit air handling units UNI 2, 3 og 4

PRODUCT DATA COMPACT S BY NILAN. Sanitary hot water production. Passive heat recovery. Comfort heating. Ventilation < 375 m 3 /h. Active heat recovery

GOLDTM. Air Handling Units with Built-in Control Equipment that offer Economical Operation.

SINGLE-ROOM VENTILATION. for schools and public spaces

CUMULUS CUMULUS. Key figures. Construction. Function Integrated chilled beams

Series VENTS MPA...W. Supply units with the air capacity up to 6500 m 3 /h in the compact sound- and heat-insulated casing with water heater

COMPACT Air & Heat. Contents

Bevent Rasch. FIDs. - Fire /05/18

PRODUCT DATA COMFORT 1200 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 1400 m 3 /h

Models Vallox 096 MC R Vallox 096 MC L. Document D2609 MANUAL. Valid from Type Updated Manual.

DOMEKT. Heat Recovery Air Handling Units

panel filters with filtering class G4. Supply filter F7 can be supplied with the few models.

Home Solutions for Residential Ventilation

Fresh air unit ALB. ALB it s simple and so easy! Air supplied through a heater and filter in a single unit.

SAVE gives great indoor climate and saves energy

TURBO HOODS. Product Brochure

UV-TURBO HOODS. Product Brochure

290 on. 286 on. Comfortable climate with pre-heated, filtered supply air. Fresh air boxes ALB WW MODEL WITH WARM WATER HEATING

TopMaster Air Handling Unit

Axial fans The right fan for every house

DX SYSTEM HEAT RECOVERY ENHANCED BY DEMAND CONTROLLED VENTILATION

Residential Heat Recovery Ventilation. REHVA European Guidebook No 25

TopVent Design Handbook

SAM. Small Air Handling. VES SMALL AIR HANDLERS part of a complete range of innovative, flexible products from the HVAC experts

Technical documentation. ComfoAir XL The latest generation of ventilation units with heat recovery

Energy saving ventilation Air handling units (Catalogue no. 2) Industrial and commercial ventilation. (Catalogue no. 1)

Lo-Carbon Sentinel Kinetic Horizontal

CI/SfB (57.5) November 2008

39HX. High-efficiency dual-flow air handling unit PRODUCT SELECTION DATA. Plug & play unit (built-in control) Class A+ across entire range

Ventilation unit Zehnder ComfoAir 200

Instructions for use

Healthy, comfortable and energy-efficient ventilation

RoofVent Design Handbook

OVERVIEW and SYSTEM GUIDE. Swegon CASA. Residential ventilation for optimal operating economy and the greatest comfort.

Framework is anodised aluminium with airtight door seals and manual door catches which can be tool locked in position.

Heat Recovery Air Handling Units

GLOBAL LP. Ceiling-mounted ventilation unit with plate heat exchanger

EASYAIR COMPACT DEVICE THE EASY WAY OF AIR HANDLING.

ESAR SMOKE CONTROL DAMPER» TECHNICAL CATALOGUE

MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR)

CONDOR. Supply air ceiling QUICK FACTS

PRODUCT DATA VPL 28 BY NILAN. Ventilation & active heat recovery. Active heat recovery. Comfort heating. Comfort cooling.

Smoke Control Ducts and Dampers For Single Compartment Applications. Fulfilling new requirements for EN product standards for CE Marking

ROOFTM. roof products. Roof products for a complete ventilation system HOME VENTILATION

WHHR125DC - Aera. Whole House Mechanical Ventilation with Heat Recovery - MVHR

MODBUS RS485. » Technical instructions. Air Comfort. Housing ventilation

Silencer Preheater unit Electric post-heating unit Water circulated post-heating unit CO 2 sensor %RH sensor Pressure difference switch LON converter

PRODUCT DATA VPL 15 TOP M2 BY NILAN. Ventilation & active heat recovery. Active heat recovery. Comfort heating. Comfort cooling.

Orion-LØV LØV-R with Sirius

GLEC exhaust FAN. Air Comfort. Air movement. Duct & Box Fans

Transcription:

Heat recovery unit RDKS Heat recovery unit RDAS is based on our RDAR unit and develops this further. The unit has a rotary heat exchanger with stepless speed control. This allows for very precise temperature control, resulting in higher accuracy of the desired supply air temperature. In addition, a function which automatically limits the rotary heat exchanger s moisture recovery at high levels of humidity in the indoor air, is available as an optional extra. The RDKS unit is equipped with the Fläkt Woods control system Curo, supplemented by a graphic control panel Curo Touch or a simpler membrane panel Curo Basic. The unit is primarily intended for housing units and smaller commercial premises, and should be located in a warm space. It does not require draining, which is an advantage, particularly when replacing older units. RDKS, which can be supplied in a right-hand or left-hand design, has all connections at the top and is designed to be mounted on a wall. As the unit is located in a kitchen it is teamed with a cooker hood, CPDJ or CPTJ. The cooker hood has a forced air damper which opens during cooking. Basic flow in the kitchen is provided using a separate exhaust air valve. RDKS is delievered with 2 m connection cable for control panel. Energy savings RDKS is an energy-efficient heat recovery unit which substantially reduces energy consumption. Savings are achieved because the fans are driven by modern, high-efficiency EC-motors where measurements point to an energy consumption of just 50% - 60% of the corresponding figure for conventional AC motors. In addition, RDKS is equipped with a rotary heat exchanger with a temperature efficiency of up to 83%. RDKS 0 20 40 60 80 100 120 140 160 l/s Product facts Efficiency up to 83% Automatic limit on moisture recovery Variable speed rotary heat exchanger Supply and exhaust air flows 20-65 l/s Recommended for residential areas of up to 155 m 2 Filter up to class F7 High-efficiency EC motors Individually adjustable fans Does not require draining Easy to install Easy to service Graphic control panel Curo Touch (optional) Modbus communication VVS AMA Standard code QAB Product code example: RDKS-1-1-1-2-0-0-1 Heat recovery unit RDKS with post-heating, moisture control and standard filter. Fläkt Woods 9299 GB 2013.11 1 We reserve the right to make changes

Description, materials, technical data Casing The outer and inner casing is made of galvanised steel with an intermediate layer of 15 mm expanded polystyrene insulation. Screws are used to lock the unit door. Fans Fans are driven by very quiet and energy-efficient EC motors. These are easy to remove for service and main te nance. The speed of the fans can be adjusted steplessly independently of each other. Supply air fan 300 200 100 65 70 L wa db(a) Heat exchanger The heat exchanger is a rotary heat exchanger made of aluminium and it has a temperature efficiency of up to 83%. It has stepless speed control and is controlled automatically by the built-in control unit. The unit is also equipped with automatic defrosting. The heat exchanger is easy to remove for cleaning. In systems with a unit in the kitchen, the air from the cooker hood bypasses the heat exchanger to avoid transfer of odours. Pre-heater and Post-Heater The unit has space for built-in electric pre-heater and post-heater. In areas where the design external temperature (DUT5) is lower than 25 C the unit should be supplemented with a pre-heater. The pre-heater is controlled by the external temperature. The unit postheater controls the supply air temperature. The unit can easily be fitted with a pre-heater and post-heater retrospectively. Filter The unit is fitted with class M5/G3 filters as standard. Filters up to class F7 are available as accessories. Sound The sound power level L w in octave bands to duct is calculated by adding the correction factor (including relevant sign) to the sound pressure level L wa reading in diagram 1. Sound path - Octave bands, mid-frequency Hz correction, db 63 125 250 500 1000 2000 4000 8000 Supply air & extract air +7 +8 +3 5 6 11 19 25 Exhaust air & outdoor air 2 6 7 19 26 40 40 40 Surroundings +8 +12 +7 +1 2 13 18 19 The sound pressure level Lp 10A is shown for a room with a 10 m 2 sound absorption area. To obtain the real sound level, the following db(a) values (including signs) are added to the reading from the diagram. Room area Normally furnished room Heavily furnished room 5 m 2 +2 db(a) +7 db(a) 10 m 2 0 db(a) +4 db(a) 15 m 2-1 db(a) +1 db(a) p s, Pa Diagram 1. a) Supply air fan, setting potentiometer (V) b) Sound to duct, L wa, for supply air fan c) Filter M5 Exhaust air fan p s, Pa 50 40 30 300 200 100 50 40 30 55 L p10a, db(a) 20 10 20 30 40 50 60 70 q, l/s Diagram 2. a Exhaust air fan, setting potentiometer (V) b) Sound to kitchen, Lp 10A, from unit with closed forced air damper in the cooker hood c) Filter G3 25 60 6 5 20 10 20 30 40 50 60 70 q, l/s 30 10 d) If RDKS is installed between two kitchen cabinets together with a front door, the sound level to the surrounding area is reduced by 1-2 db. 5 35 7 6 8 40 7 9 8 10 9 Fläkt Woods 9299 GB 2013.11 2 We reserve the right to make changes

Dimensions and weight, electrical data, control equipment Dimensions and weight Fan control 32 380 Three operating modes can be selected via the control panel (accessory): AWAY is used when nobody is at home for a longer period in order to save energy HOME is used for normal ventilation flow 600 FORCED is used when there is a greater need for ventilation (it will automatically revert after 120 minutes). 595 Weight: 40 kg The fan speeds can be adjusted steplessly, independently of each other through one of our control panels (optional). The values read from Curo Basic with flashing LEDs and Curo Touch in plaintext. 183 265 285 78 240 203 115 70 A F 595 U RDKS-1 Outdoor air right, supply air right T 203 240 70 115 83 188 Temperature control The control unit controls the rotary heat exchanger and any post-heating devices to maintain the set temperature. The supply air temperature is adjusted towards the desired setpoint value in two steps. First, using energy recovery from the rotary heat exchanger, and, if this is not enough, using the post-heater. The electric post-heater is only activated if the rotary heat exchanger is operating. During cold periods, when frost may form in the impeller, the control unit takes care of defrosting. This occurs when the external temperature falls below 10 C. 188 83 U T 595 A RDKS-2 Outdoor air left, supply air left F 78 183 265 285 Cooling recovery In the summer, if the exhaust air is cooler than the outdoor air, the rotary heat exchanger starts to recover cooling from the cooler exhaust air. This primarily applies if there is some form of refrigeration machine in the house. Connection (female) T F U A Diameter 125 100 100 125 Control equipment Supply air Exhaust air 1) Outdoor air 1) Extract air 1) Increased to Ø125 as soon as the space allows. Electrical data Voltage: 230V, single phase 50 Hz. Code Fan motors Preheater Afterheater Rated output Rated output Rated output, W electric, W electric, W electric, W 1) w cooker hood RDKS 2 x 83 500 500 1170 1210 1) Rated output applies when both preheater and afterheater are installed. Packaging The unit is delivered in a cardboard box. Mounting brackets for fixing the unit to a wall, as well as installation, operation and maintenance instructions are included. The unit is equipped with an electronic control unit, which is located behind the protective panel and, among other things, controls the operation of the fans, the rotary heat exchanger, and any electric heaters. Moisture control (optinal) The function will automatically limit the rotary heat exchanger moisture recovery at high levels of humidity in the indoor air. Humidity control can also be ordered in retrospect for completion, with the product code: RDKZ- 51-1. Ethernet connection (optinal) The Ethernet connection can be used to connect the unit to an existing network. RDKS has a built-in Webserver which makes it possible to surf into the unit and read and change certain values. For instance, fan speeds and temperatures. The connection can also be used for connecting the unit to a superior system via Modbus TCP/IP. Alarm The control panel (accessory) has an alarm indicator. This indicates when it is time to change the filter. Fläkt Woods 9299 GB 2013.11 3 We reserve the right to make changes

Product code, accessories Product code Heat recovery unit with rotary heat exchanger Connection (a) 1 = Outdoor air right, supply air right 2 = Outdoor air left, supply air left Electric battery (b) 1 = Post-Heater only 2 = Pre-Heater and Post-Heater Moisture control (c) 1 = With Filter Supply air/exhaust air (d) 2 =M5 bag filter/g3 filter pad Air quality control (e) Ethernet connection (f) 5 = With Generation (g) 1 Accessories Front cover Material (b) 3 = White lacquer 4 = Stainless Extension unit towards the ceiling (c) 1 = With (+300 mm) Height (d) 6 = 600 7 = 700 Generation (e) 1 Extension cable for control panel Version (b) 1 = 6-pole flat cable Length (cc) 10 = 10 metres 25 = 25 metres RDKS-a-b-c-d-e-f-g RDKZ-14-b-c-d-e RDKZ-43-b-cc-d Control panel Curo Basic Control panel Curo Touch Filter G3 filter pad Filter M5 bag filter Filter F7 bag filter Accessories Control panel Curo Basic - RDKZ-41-1 External control panel for wall mounting. The fan speed can be set to three operating modes: AWAY, HOME and FORCED. The panel also shows filter alarm. Control panel Curo Touch - RDKZ-41-3 External control panel for wall mounting. The control panel is used to adjust fan speeds, CO 2 control and operating speeds which are shown i plaintext. The control panel also shows alarm, etc. NOTE! Control panel is required for adjustment of fans. Dual wall vent RDKZ-26 The dual wall vent is intended to take in outdoor air and transport away exhaust air from heat recovery units fitted in residential buildings. It is installed on an external wall. The outdoor air is taken in from below, while the exhaust air is blown straight out. Both openings are fitted with netting. The netting across the exhaust air opening is easy to remove for inspection and cleaning if necessary. Air intake BSDB-20 RDKZ-41-1 RDKZ-41-3 RDKG-99-14 RDKG-99-15 RDKG-99-16 Electric battery for adding retrospectively RDKR-99-03 (suitable both as a pre-heater or post-heater) Cooker hood for RDKS-1-b-c-d-e-f-1 Cooker hood for RDKS-2-b-c-d-e-f-1 Cooker hood for RDKS-1-b-c-d-e-f-1 Cooker hood for RDKS-2-b-c-d-e-f-1 Combined hood Air intake Ventilation hood Duct insulation ø 100 Duct insulation ø 125 Silencer Moisture control Ethernet connection CPDJ-b-cc-d-1-f CPDJ-b-cc-d-2-f CPTJ-a-bb-c-1-e CPTJ-a-bb-c-2-e RDKZ-26-000 BSDB-20-012 CBAE-12-111 RDKZ-45-010 RDKZ-45-012 BDER-70-012-100 RDKZ-51-1 RDKZ-53-5 Is intended for fitting on an external wall. The intake consists of a box in which an external wall grille is fitted as rain cover. It therefore does not need to be in a location protected from rain. Generation (d) 1 Fläkt Woods 9299 GB 2013.11 4 We reserve the right to make changes

Accessories, cont Ventilation hood CBAE-12 Is intended for the exhaust air from the heat recovery unit. It should be connected using metal ducting or a flexible steel hose. Duct insulation RDKZ-45 Is intended for thermal insulation of ducts which convey cold air through heated spaces. The duct insulation comprises fire-proof polyethylene cellular plastic. The insulation thickness is 15 mm and the length is 1 metre. Duct insulation is fitted from the end of the duct. Silencer BDER-70 Rectangular silencer for duct diameter 125 mm. L x W x H = 1000 x 265 x 190. Mid-frequency, Hz Sound attenuation at 63 125 250 500 1000 2000 4000 8000 BDER-70-012-100 19 18 26 43 51 47 48 43 Fläkt Woods 9299 GB 2013.11 5 We reserve the right to make changes