Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Similar documents
Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Dräger Polytron 8200 CAT Detection of flammable gases and vapors

Dräger Polytron 8310 IR Detection of flammable gases and vapour

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Dräger Polytron 5720 IR Toxic Gas Detection

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Dräger Polytron 8100 EC Detection of toxic gases and oxygen

Dräger Polytron 8100 EC Detection of toxic gases and vapors

Dräger Polytron 5720 IR Detection of carbon dioxide

Dräger Polytron 8720 IR Detection of carbon dioxide

Dräger Polytron 8000 Stationary gas detector (EC)

Dräger Polytron 8200 Stationary gas detector (CatEx)

Dräger Polytron 8310 Stationary gas detector (DSIR)

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

Dräger Polytron 8000 Stationary gas detector (EC)

Dräger PIR 3000 Detection of flammable gases and vapours

Dräger Polytron 7000 Fixed gas detector

Dräger Polytron Pulsar 2 Detection of flammable gases and vapours

Dräger PointGard 2100 Detection of toxic gases and vapours

Dräger REGARD -1 Control System

Dräger X-am Dräger X-am 7000: Modular, rugged and waterproof.

Dräger PIR 7200 Detection of toxic gases and oxygen

Dräger PIR 7200 Toxic Gas Detection Transmitter

Dräger PIR 7000 Flammable Gas Detection

Dräger Polytron 7000 Detection of toxic gases and oxygen

Dräger X-am Dräger X-am 3000: Designed for the harshest industrial environments.

Dräger REGARD -1 Control System

Catalytic Bead DrägerSensor Sensors for Fixed Gas Detectors

Dräger Polytron Pulsar 2 Open Path Gas Detector

Dräger X-am 2500 Multi-Gas Detection

Dräger Flame 2350 (UV&IR) Flame Detection

Dräger Flame 2500 (IR3) Flame Detection

Dräger Flame 2100 (UV) Flame Detection

Dräger Polytron Pulsar 2 Detection of flammable gases and vapours

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

Dräger REGARD -1 Control System

Dräger Flame 2100 Flame Detection

Dräger Flame 2370 (UV&IR) Flame Detection

Dräger QuadGard Control System

Dräger Flame 2700 (Multi-IR) Flame Detection

Dräger X-am 2500 Multi-Gas Detector

Dräger PEX 3000 Flammable Gas Detection

Dräger X-am 7000 Multi-Gas Detection

Dräger Polytron SE Ex Fixed Gas Detector

Dräger X-am 5600 Personal Monitor Multi-Gas Detection Device

Catalytic Bead DrägerSensors for Fixed Gas Detectors

Dräger X-am 5000 Multi-Gas Detection

ULTIMA XL/XT Series Gas Monitors. [ Ultimate Features Extreme Design ]

Dräger Flame 2500 Flame Detection

Dräger REGARD 3900 Series Control System

S5000 Gas Monitor. GMS5000.com

Dräger X-am 5000 Multi-Gas Detector

ULTIMA X5000. MSAX5000.com

Sieger Apex. Flexibility that meets your requirements

Dräger X-am 5000 Multi-Gas Detection

OLC(T) 100 FIXED GAS DETECTOR

Sensepoint. Fit For Purpose Flammable, toxic and Oxygen versions available High performance, low cost Suitable for new and retro fit applications

Zareba Sensepoint Pro

IR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance

The SharpEye 40/40I (IR3) Flame Detection

Dräger GS01 (wireless) Detection of flammable gases and vapours

OLCT 700 & 710. Certifications FIXED GAS DETECTION. Better detection. Better protection.

Dräger Pulsar 7000 Series Detection of flammable gases and vapours

Xgard. Fixed detectors For flammable, toxic or oxygen gases

PrimaX IR Gas Transmitter Designed for Reliable Performance in Extreme Conditions

Model D12-IR. Digital Gas Transmitter...

GS01 (wireless) Detection of flammable gases and vapours

Dräger X-am 7000 Multi-Gas Detection

3M Oldham OLCT 100. Description. Fixed Gas Detector

SUPREMATouch. Modular Fire & Gas Detection System

INFRARED PRODUCTS FOR MONITORING SMOKELESS FLARES, PILOTS, AND FLAME INTENSITY

Electrochemical DrägerSensor Sensors for Fixed Gas Detectors

Electrochemical (EC) DrägerSensors for Fixed Gas Detectors

The SharpEye 40/40R (IR) Flame Detection

The SharpEye 40/40L4-L4B (UV/IR) Flame Detection

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Certifications. The Fixed Gas Detection People

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Aluminium or Stainless Steel version

P R O D U C T D ATA S H E E T

OLCT 100 DETECTION DE GAZ FIXE. Certifications. Better detection. Better protection. Detection of Combustible, Toxic or Oxygen gases

Dräger Flame 5000 Flame Detection

The SharpEye 40/40M (Multi IR) Flame Detection

The SharpEye 40/40I (IR3) Flame Detection

SIL 2. Ultima X Series Gas Monitors CERTIFIED

Gas cylinder scale Model GCS-1

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

Dependable Solutions for Gas Detection

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

Danfoss gas detection unit Type GD Heavy Duty

SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System

Sensepoint. Fit For Purpose Flammable, toxic and oxygen versions available High performance, low cost Suitable for new and retro fit applications

Dräger Polytron 5200/53X0. Instructions for Use

Dräger Pac 6000 Single-Gas Detector

Pac Ex 2. Elegant and smart Explosive hazards and lack or surplus of oxygen under control

OPTIBAR DP 7060 Supplementary Instructions

Dräger Polytron (approved as type P3S) Transmitter for electrochemical Sensors. Instructions for Use. ST eps

Dräger Flame 5000 Flame Detection

ST More than the sum of their components GAS DETECTION SYSTEMS

Transcription:

Dräger Polytron 5200 CAT Detection of flammable gases and vapours The Dräger Polytron 5200 CAT is a cost-effective explosion-proof transmitter for the detection of flammable gases in the lower explosion limit (LEL). It uses a catalytic bead DrägerSensor Ex DD that will detect most flammable gases and vapours. A 3-wire 4 to 20 ma analogue output with relays makes it compatible with most control systems. Menu control Backlit display LED status display D-32407-2011 DrägerSensor Ex DD

02 Dräger Polytron 5200 CAT Benefits Fast and stable the DrägerSensor Ex DD The latest generation-type DD gas sensor is based on a proven catalytic bead principle. Innovative dual active elements result in good long-term zero stability. Dräger has raised the bar for poison resistance yet again. Its long service life ensures that ownership costs remain low. Performance measurement has also been improved. The innovative gas inlet enables the sensor to detect gas within a matter of seconds. Same design, same operating principles Polytron 5200 belongs to the Dräger Polytron 5000 series. All transmitters in this series have the same design and user interface. This allows for uniform operation with reduced training and maintenance requirements. The backlit display shows status information clearly with quick access to functions using a non-intrusive magnetic wand. The gas concentration and measurement unit are displayed during normal operation. Coloured LEDs (green, yellow and red) provide additional alarm and status information. Three relays for controlling external equipment The Dräger Polytron 5200 can also be supplied with three integrated relays upon request. This enables you to use it as an independent gas detection system with two adjustable concentration alarms and one fault alarm. Audio alarms, signal lights or similar devices can thus be controlled locally without an additional cable between the transmitter and central controller. Safe, robust housing for every application The Polytron 5200 features a Class I, Div. 1 rated explosion-proof enclosure made from aluminum or stainless steel, making it suitable for a wide range of environmental conditions. A protection type e version includes a convenient docking station that allows installation in hazardous atmospheres without running conduit (where approved). Make the impossible possible with the remote sensor An available remote sensor condulet housing allows the sensor to be installed up to 30 metres (100 feet) away from the Polytron transmitter. The sensor splash guard with integrated tubing nipple enables one person to perform a full calibration of a remote mounted sensor from the transmitter.

Dräger Polytron 5200 CAT 03 System Components Dräger REGARD 3900 The Dräger REGARD 3900 is a standalone, self contained control system for the detection of Toxic, Oxygen and Ex hazards. The control system is fully configurable between 1 and 16 channels, depending upon the type and quantity of input/output boards installed. ST-335-2004 D-27777-2009 Dräger REGARD -1 The Dräger REGARD -1 is a standalone, self contained single channel control system for the detection of Toxic, Oxygen and Ex hazards. The control system is fully configurable for a single input from either a 4 to 20 ma transmitter or a Dräger Polytron SE Ex measuring head. Accessories Docking station The docking station is included with all transmitters in the Polytron 5000 and Polytron 8000 series for protection type e, increased safety. This also facilitates pre-assembly. D-15035-2010

04 Dräger Polytron 5200 CAT Accessories Splash guard The Splash guard protects the sensor against splash water and dirt. D-85345-2013 D-85369-2013 Duct mount kit The duct mount kit enables gas monitoring inside ventilation ducts while keeping the transmitter outside.

Dräger Polytron 5200 CAT 05 Technical Data Dräger Polytron 5200 CAT Type Gases Measuring ranges Display Electrical data Environmental conditions (see sensor data sheet) Housing Approvals* Explosion-proof / flameproof enclosed transmitter ( d ) or combined with increased safety ( d/e ) flammable gases and vapours DD LC 0 to 100% LEL 0 to 10% LEL Backlit graphic LCD; 3 Status LEDs (green/yellow/red) Signal output analogue Power supply Power consumption (max.) Relay specification (option) Temperature Pressure Humidity Transmitter housing Sensor housing Enclosure protection type Cable entry point Approx. dimensions (H x W x D) Weight, approx. Normal operation Maintenance Fault 10 to 30 V DC, 3-wire w/o relay, non-remote 4 to 20-mA Constant 3.4-mA or 4-mA ±1 ma 1 Hz modulation; (adjustable) < 1.2 ma 95-mA at 24 V w/ relay, remote 145-mA at 24 V 2 alarm relays and 1 fault relay, single-pole two-way contact 5 A @ 230 VAC, 5 A @ 30 VDC, resistance-bound -40 to 80 C (-40 to 176 F) without relay -40 to 70 C (-40 to 158 F) with relay 20.7 to 38.4 inch Hg / 700 to 1,300 mbar 0 to 100% RH, non-condensing Epoxy coated copper-free aluminum or SS316 L stainless steel 303 Stainless steel NEMA 4X & 7, IP65/66/67 3/4 NPT threads or M20 cable gland w/o docking station 11.0" x 5.9" x 5.1" / 280 x 150 x 130 mm w/ docking station 11.0" x 7.1" x 7.5" / 280 x 180 x 190 mm Aluminium w/o docking station SS316 L w/o docking station Aluminium w/ docking station SS316 L w/ docking station UL Class I, Div 1, Groups A, B, C, D; Class II, Div 1, Groups E, F, G; Class I, Zone 1, Group IIC; T-Code T6/T4 CSA Class I, Div 1, Groups A, B, C, D; Class I, Zone 1, Group IIC; T-Code T6/T4 IECEx ATEX CE markings Performance approval (for DD sensor only) CSA C22.2 No. 152 4.9 lbs / 2.2 kg 8.8 lbs / 4.0 kg 7.7 lbs / 3.5 kg 11.9 lbs / 5.4 kg Ex db IIC T6/T4 Gb, -40 Ta +40/+80 C; d version Ex db e IIC T6/T4 Gb, -40 Ta +40/+80 C; e version Ex tb IIIC T80/130 C Db II 2G Ex db IIC T6/T4 Gb, -40 Ta +40/+80 C; d version II 2G Ex db e IIC T6/T4 Gb, -40 Ta +40/+80 C; e version II 2D Ex tb IIIC T80/130 C Db ATEX (Directive 2014/34/EU) Electromagnetic Compatibility (Directive 2014/30/EU) Low Voltage (Directive 2014/35/EU) BVS 15 ATEX G 001 X

06 Dräger Polytron 5200 CAT Technical Data * All docking station versions are ATEX/IECEx approved Ordering Information Dräger Polytron 5200 CAT Dräger Polytron 5200 CAT DD d A 83 44 150 Dräger Polytron 5200 CAT DD d A relay 83 44 151 Dräger Polytron 5200 CAT DD e A (incl. Docking Station) 83 44 154 Dräger Polytron 5200 CAT DD e A relay (incl. Docking Station) 83 44 155 Dräger Polytron 5xx0 Kit (Custom configuration e. g. stainless steel housing) 83 44 500 Accessories Magnetic wand 45 44 101 Pipe bracket 45 44 198 Duct mounting kit 68 12 725 IR Connection Kit Polytron 5000/8000 45 44 197 PolySoft 83 23 405 PolySoft premium 83 23 411 Splash guard 68 12 510 Gassing adaptor PE incl. tubing 45 09 314 Viton calibration adaptor 68 10 536 Stainless steel process adaptor for DD 68 12 470 Stainless steel process adaptor for LC 68 12 465 Viton is a DuPont registered trademark. 90 41 367 16.06-3 HQ PP Subject to modifications 2016 Drägerwerk AG & Co. KGaA

Thank you for reading this data sheet. For pricing or for further information, please contact us at our UK Office, using the details below. UK Office Keison Products, P.O. Box 2124, Chelmsford, Essex, CM1 3UP, England. Tel: +44 (0)330 088 0560 Fax: +44 (0)1245 808399 Email: sales@keison.co.uk Please note - Product designs and specifications are subject to change without notice. The user is responsible for determining the suitability of this product.