Domestic hot water (DHW) The substation can be supplied with connection pipes for DHW cylinder on the supply or return line.

Similar documents
Instructions. VX Solo II. 1.0 Table of contents

Instructions for installation and use Akva Lux II VX substations 1. Contents

60 C water temperature ensures thermal disinfection during hot water production

Akva Lux TDP-F District heating flat station for direct heating and domestic hot water systems

HW 22 District heating substation for indirect heating and domestic hot water systems

Akva Vita TDP-F District heating flat station for direct heating and domestic hot water systems

Akva Lux VX District heating substation for indirect heating and domestic hot water systems

T. +44 (0) E.

ModuSat TP. Energy. Heat Interface Units

Operating Guide. Termix Compact 28 VX-FI / HWP / HWS. 1.0 Table of Contents. 1.0 Table of Contents

Akva Vita TDP District heating flat station for direct heating and domestic hot water systems

ModuSat TP. Energy. Heat Interface Units

WL Instantaneous water heater

a Danfoss Platform for Flensburg Secondary Network

FHM-Cx Mixing Shunts for Floor Heating

VXi. Indirect, fully insulated district heating subtations Akva Lux II VXi, VXi Solo. Fully insulated for very low heat losses.

Data Sheet. Compact Mixing Shunt for Floor Heating, FHM-Cx. Application:

ThermoDual Domestic hot water charging system

Reno Exchange of gas boilers.

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)

Installation and operation manual for mixing modules FH-MJB and FH-MJC

Design & Product Guide. Danfoss FlatStations.

FHM-Cx Mixing Shunts for Floor Heating

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)

Technical paper Hydraulic balance in a district cooling system

Contact person RISE Date Reference Page Björn Folkeson P03675B 1 (11) Energy and circular economy

heat interface units A BOILER WITHOUT A FLAME HIU Single PHE options

Akva Vita Instantaneous water heater

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)

Operating Guide. Termix Solar A+/B+ 1.0 Table of Contents. 1.0 Table of Contents

MAKING MODERN LIVING POSSIBLE. Akva Lux II TDP-F. Instructions for installation and use. Danfoss District Energy

CALEFFI. SATK wall-mounted heat interface unit Fitted for connection to DHW storage. SATK40 series 01216/14 GB

Metering systems 0548EN April 2014

SATK wall-mounted Heat Interface Unit (HIU) Instantaneous domestic hot water production

Hydraulic balance in a district cooling system

MAKING MODERN LIVING POSSIBLE. Akva Vita II TD & S Akva Lux II / Akva Les II TD & S. Instructions for installation and use. Danfoss District Energy

AVTI Multifunctional self - acting controller

TA-COMFORT-S. Prefabricated units Heating interface unit for surface heating and hot water services

The ECL Comfort 110 is a universal 1-circuit controller for use in district heating substations and district heating systems as well as boilerbased

Valves, controls + systems. Local and district heating technology. Innovation + Quality. Product range. for improved.

Danfoss prefabricated floorheatingunit Type FH-G/FH-GS/FH-GR/FH-GRS

Wall-mounted substation PKL-113

Installation Guide. Termix Distribution unit. 1.0 Table of Contents. 1.0 Table of Contents

30% Safe. Take lead on your project with an efficient system concept. Technical handbook Danfoss EvoFlat systems from A-Z. evoflat.danfoss.

Temperature controller for steam (PN 25) AVT / VGS - external thread

30% Take lead on your project with an efficient system concept. lower energy.

ThermoClean Domestic water heating system with legionella growth prevention through thermal disinfection

1 valve needed instead of 3 for pressure, flow and zone control of water-based heating systems.

Systems for central heating

Herz York Direct Heat Interface Unit

ECL Comfort V a.c. and 24 V a.c.

Installation Guide DSA 1 MINI. Contents

SATK 30 heat interface unit

ECL Comfort V a.c. and 24 V a.c.

Technical paper Selection of district heating house stations

CS TSV MIX-REGULUS CS TSV MIX REGULUS. Installation and Operation Manual CS TSV MIX REGULUS PUMP STATION - for boilers and heating systems

CS TSV MIX REGULUS PUMP STATION - for boilers and heating systems

Cylinders for Domestic Purposes Heat Pumps

Temperature controller AVT with safety temperature monitor STM / VGS for steam (PN 25)

CALEFFI. Set point thermostatic regulating unit. 182 series 01190/18 GB. replaces dp 01190/15 GB

CALEFFI. Thermostatic regulating unit for heating systems. 166 series 01238/17 GB. replaces dp 01238/15 GB. Function

TA-COMFORT-S. Prefabricated units Heating interface unit for surface heating and hot water services

T. +44 (0) E.

IDEA CAMPUSENERGY2017 February Miami, FL

Packaged Instantaneous Domestic Hot Water Generator Energy Source: Boiler Water

manifold, for radiators

Technical data. Danfoss DHP-A

Technote. Frese AquaHeat HW - DH. Application. Design. Features and Benefit. Operation. Optional.

LK Heat Exchanger Pack 10 -n

RA 2000 Series RA 15/6T & TB Conversion Valve

ACCREDITED. Product range Code A2L Pre-assembled set point temperature regulating unit with manifolds and box, with UPM3 Auto L pump

Stored Water District Heating Interface Units. Heat Interface Units

THERMAL STORE MAINS PRESSURE SYSTEM

Solar heating systems

The solutions are here The choice is yours...

RA15/6T & TB Conversion Valve

80HMA. Comfort Module Range for Monobloc Heat Pumps. Compact comfort module. DHW management possibility. Multi zone option control.

UK-specific appendix to Installation instructions DHP-A DHP-A Opti DHP-AQ Maxi DHP-H DHP-H Opti DHP-H Opti Pro DHP-L DHP-L Opti DHP-L Opti Pro

Brazed heat exchanger XB

Installation, Operation and Maintenance Instructions for Electric Storage Calorifier

INSTRUCTIONS REHAU PRO-BALANCE MIXING MODULE

TURBINE OIL FILTRATION AND DEHYDRATION UNIT - technical documentation - MODEL T1250

Installation, Operation and Maintenance Instructions Thermaflow E Plate Heat Exchanger Package OM013

HERZ Differential Pressure Control Valve 4002

heat interface units A BOILER WITHOUT A FLAME

Technical Product Guide

RADIANT PANEL SYSTEM CONTROL QUICK GUIDE

Product range Code HE1 Connection and energy management compact unit without anti-condensation valve

Indirect Expansion. USER MANUAL FOR OPERATORS AND PLUMBERS HEAT INTERFACE UNITS

Meibes Heat Interface Unit (HIU) A2RXE Instantaneous Hot Water & Space Heating

Installation, Operation and Maintenance Instructions Electric Flow Heater OM009

union swing check valve spring loaded check valve purging valve pressure relief valve relief valve metered balancing valve

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model EGIS - AS. R EN - Edition 03-01/03/2008

Balancing & Control. Frese PV Compact. Differential Pressure Control Valve

New Zip AquaFlo. Stainless steel cylinders for mains pressure hot water

HERZ Regulating valve 4002

Vortex 15/21 Utility and Outdoor Module Vortex Combi 21 and Outdoor Vortex Combi 21

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model COMBI A. R EN - Edition 09-23/09/2011

VHX Valve Sets with RAX Thermostatic Sensor for Designer Radiators & Bathroom Towel Rails

V2, V4 and V8 Thermostats Self-acting Temperature Controls I GB-1. Characteristics. Applications. Function. Design

Transcription:

MAKING MODERN LIVING POSSIBLE VX Solo II Substation for single-family, semi-detached and terraced houses as well as flats District heating substation for indirect heating. With connection pipes for W cylinder. Designed for wall-mounting with pipes connection in top or bottom Application The VX Solo II is a substation featuring high performance and simple operation. The VX Solo II is especially suitable for two-pipe systems and systems with floor heating. District heating () The substation is prefabricated with interconnecting components such as fitting piece and sensor pockets for insertion of a heat meter mounted in the return pipe, as well as strainer, ball valves and pockets for pressure gauges. As a standard the substation is supplied with fitting piece for mounting of heat meter in the return pipe. Heating () The heating side consists of a stainless steel plate heat exchanger, manometer, thermometers, expansion vessel and circulation pump(s) and the heating temperature is controlled by an self-acting thermostatic valve or an electronic temperature controller with an outdoor temperature sensor, in combination with an actuator. Depending on substation s application, different heat exchangers dimensioned for central or floor heating can be used. As an option the substation can be equipped with a thermostat with safety monitor. Domestic hot water (W) The substation can be supplied with connection pipes for W cylinder on the supply or return line. Construction All pipes are made of stainless steel. The connections are made by nuts and gaskets. The substation offers variable connection possibilities, as connection of pipes can be established both in the top or in the bottom of the substation. The VX Solo II can be delivered with white-lacquered steel cover, with door. Variants VX Solo II is available in various variants. The circuit diagram and the technical data on the back page illustrates VX Solo II HWS with 1 heating circuit and secondary connection for W cylinder, however, variants with 2 heating circuits, mixing loop and primary connection for cylinder are also available. Enclosed application sheet illustrates the available variants. FeATURES AND BENEFITS Substation for single-family houses Indirect heating, - one or two heating circuits Selfacting or electronic control of heating () temperature Connections for W cylinder on supply or return line Pipes connection in top or bottom of substation = Savings in installations costs Pipes and heat exchanger made of stainless steel, connections with EPDM gaskets. Minimized risk of lime scale and bacteria formation Electrical wiring from factory - Plug & Play Capacity: 20-30 kw / 15 kw FH districtenergy.danfoss.com

VX Solo II Circuit diagram example, VX Solo II HWS (ECL 210/A237) - 1 circuit + sec. connection for W cylinder 1 Plate heat exchanger, with 8 Circulation pump, 8A Circulation pump, cylinder 11 Safety valve, 3 bar ½ 12 l 24 Fitting piece for heat meter 3/4 x 25 Controller Danfoss ECL210/A237 28 Immersion sensor ESMB 29 Danfoss actuator AMV 150 integrated control valve AHQM limit Reurn Design specifications: Nominal pressure (prim/sec.): PN 16 / PN 3 Max. supply temperature: 120 C (design temp.) Min. ΔP: See capacity examples Brazing material (X): Copper Weight incl. cover: 46 kg (incl. packing) Cover: White-lacquered steel Dimensions (mm): Without cover: H 861 W min. 510*/max. 525** D 365 With cover: H 861 W 550 D 381 * Units with insulated plate heat exchanger type XB06H-1 26. ** * Units with insulated plate heat exchanger type XB06H-1 40. Electrical supply: Connections sizes: :, W cylinder: 230 V AC G ¾ ET (ext. thread) G ¾ ET (int. thread) 550 1 2 3 4 5 top view 6 41 780 40 861 Wall Connections: 1. District heating () supply 2. District heating () return 3. Heating () return 4. Heating () supply 5. W cylinder supply 6. W cylinder return Cover, white-lacquered steel, with door Electronic controller Danfoss ECL310 Safety function - safety thermostat + actuator Connection of pipes can be established in the top or in the bottom of the substation Pipe Mounting of heat meter (supplied by customer) Supplementary fitting set for change of fitting piece size ¾ x to fitting piece size 1 x 190 mm Heating: Capacity examples Heating capacity Plate heat exchanger circuit primary [ C] circuit sedondary [ C] Pressure loss primary* [kpa] Pressure loss (only sec. side of heat exchanger) [kpa] Danfoss Redan A/S District Heating Omega 7, Søften DK-8382 Hinnerup Denmark Tel.: +45 87 43 89 43 Fax: +45 87 43 89 44 redan@danfoss.com www.redan.danfoss.dk Flow rate primary ([l/h] Flow rate secondary [l/h] 20 XB06H-1 26 75/44 40/65 35 6.0 555 688 20 XB06H-1 26 80/49 45/70 35 6.0 555 688 20 XB06H-1 26 90/51 50/70 29 8.5 441 860 30 XB06H-1 40 75/44 40/65 55 6.0 842 1032 30 XB06H-1 40 80/49 45/70 55 6.0 832 1032 30 XB06H-1 40 90/51 50/70 40 9.0 662 1290 * Heat meter not incl. VL.GP.O3.02 Danfoss 08/2014 DKR

VX Solo II District heating substation for indirect heating and connection pipes for primary or secondary connnection of W cylinder VX Solo II (T C) 1 circuit, primary connection for W cylinder 1 Plate heat exchanger,, with 4 Differential pressure controller AVPL 8 Circulation pump 11 Safety valve 17 Air vent 24 Fitting piece for heat meter 3/4 x 30 Self-acting thermostatic valve T C 200/VS2 - RAVK 25-65/VMA thermostatic actuator for temperature control of W cylinder. H801 x W 510*/max. 525** x D 345 mm H801 x W 550 x D 381 mm VX Solo II H, ECL 210/A230 1 circuit. 1 Plate heat exchanger 8 Circulation pump 11 Safety valve 25 Controller Danfoss ECL 210/A230 29 Danfoss actuator AMV VL.GP.O3.02 Produced by Danfoss Redan A/S 08.2014 3

VX Solo II - District Heating Substation for indirect, with primary or secondary connection for W cylinder VX Solo II H2, ECL210/A260 2 circuits 1 Plate heat exchanger,, with 8 Circulation pump 10 Circulation pump FH 11 Safety valve 25 Controller Danfoss ECL 210/A260 29 Danfoss actuator AMV, 33 Danfoss actuator AMV, FH Floor limit Floor VX Solo II HWP, ECL 210/A237 1 circuit, primary connection for W cylinder 1 Plate heat exchanger,, with 4 Differential pressure controller with flow limitation AVPB-F 8 Circulation pump 11 Safety valve 25 Controller Danfoss ECL 210/A237 29 Danfoss actuator AMV, 30 2-way valve VS2 limit - RAVK 25-65/VMA thermostatic actuator for temperature control of Wcylinder. VL.GP.O3.02 Produced by Danfoss Redan A/S 08.2014 4

VX Solo II - District Heating Substation for indirect, with primary or secondary connection for W cylinder VX Solo II HWP, ECL210/A247 1 circuit, primary connection for W cylinder 1 Plate heat exchanger,, with 8 Circulation pump 11 Safety valve 25 Controller Danfoss ECL 210/A247 28 Immersion sensor Danfoss ESMB 29 Danfoss actuator AMV, 31 Danfoss actuator AMV, 32 Danfoss flow controller with limit VX Solo II H2WP, ECL210/A260 2 circuits, primary connection for W cylinder 1 Plate heat exchanger,, with 4 Differential pressure controller with flow limitation AVPB-F 8 Circulation pump 10 Circulation pump FH 11 Safety valve 24 Fitting piece for heat meter 3/4 x 25 Controller Danfoss ECL 210/ A260 29 Danfoss actuator AMV, 30 2-way valve VS2 33 Danfoss actuator AMV, FH, FH circuit, circuit 99 Thermostatic valve for W - RAVK 25-65/VMA thermostatic actuator for temperature control of W cylinder. H861 x W 650 x D 365 mm H861 x W 700 x D 381 mm limit limit FH FH VL.GP.O3.02 Produced by Danfoss Redan A/S 08.2014 5

VX Solo II - District Heating Substation for indirect, with primary or secondary connection for W cylinder VX Solo II H2WP, ECL310/377 2 circuits, primary connection for W cylinder 1 Plate heat exchanger,, with 8 Circulation pump 10 Circulation pump FH 11 Safety valve 25 Controller Danfoss ECL 310/377 28 Immersion sensor ESMB 29 Danfoss actuator AMV, 30 Flow controller with integrated control valve AHQM 31 Danfoss actuator AMV, 32 Flow controller with integrated control valve AHQM 33 Danfoss actuator AMV, FH, FH circuit, circuit H861 x W 650 x D 365 mm H861 x W 700 x D 381 mm limit limit FH FH VX Solo II HWS, ECL210/A237 1 circuit, secondary connection for W 1 Plate heat exchanger,, with 8 Circulation pump 8A Circulation pump, W 11 Safety valve 25 Controller Danfoss ECL 210/A237 28 Immersion sensor Danfoss ESMB 29 Danfoss actuator AMV, limit, circuit VL.GP.O3.02 Produced by Danfoss Redan A/S 08.2014 6

VX Solo II - District Heating Substation for indirect, with primary or secondary connection for W cylinder VX Solo II HWS, ECL210/A247 1 circuit + mixing loop, secondary connection for W cylinder 1 Plate heat exchanger,, with 8A Circulation pump, W 10 Circulation pump 11 Safety valve 25 Controller Danfoss ECL 210/A247 28 Immersion sensor Danfoss ESMB 29 Danfoss actuator AMV 33 Danfoss actuator AMV, circuit limit Radiator heating/ Floor heating VX Solo II H2WS, ECL210/A267 2 circuits + mixing loop, secondary connection for W cylinder 1 Plate heat exchanger,, with 8 Circulation pump 8A Circulation pump, W 10 Circulation pump FH 11 Safety valve 24 Fitting piece for heat meter 3/4 x 25 Controller Danfoss ECL 210/ A267 28 Immersion sensor Danfoss ESMB 29 Danfoss actuator AMV, 33 Danfoss actuator AMV 57 Safety temperatue monitor, circuit H861 x W 650 x D 365 mm H861 x W 700 x D 381 mm limit Floor Floor VL.GP.O3.02 Produced by Danfoss Redan A/S 08.2014 7

VL.GP.O3.02 Produced by Danfoss Redan A/S 08.2014 8