How to Diagnose a TXV Failurek

Similar documents
Checking the Charge on a Heat Pump in the Winter

Negative Superheat? Time to Check Your Tools

Instructors: Contact information. Don Reynolds Doug McGee Factory Tech Support

The Saturation process

SECTION 7 AIR CONDITIONING (COOLING) UNIT 41 TROUBLESHOOTING

Otherwise, you can continue reading the file on the following pages.

Before I start on this one At HVAC School we focus on a wide range of topics, many of them are very basic. My experience as a trainer for over 16

Table of Contents. Service Procedures. Service Procedures. Measuring Superheat (4) Measuring Subcooling (5) Airflow Calculation (6-8)

To accomplish this, the refrigerant fi tis pumped throughh aclosed looped pipe system.

Warm Case Troubleshooting Guide 9/18/2014

Everything You. NEED to KNOW. TXV does this by keeping the coil supplied

USING THE P-T CARD AS A SERVICE TOOL

Technical Training Associates Presents. Commercial Refrigeration Equipment Servicing Part 1

Some of these procedures need to be performed to conform to requirements of the Clean Air Act.

Refrigeration Systems and Accessories

Pressure Enthalpy Charts

Sporlan Valve Division Parker Hannifan/CIC Group

Energy Use in Refrigeration Systems

RTP Technical Bulletin

HVAC/R Refrigerant Cycle Basics

Superheat charging curves for technicians

For an administrative fee of $9.97, you can get an un-locked, printable version of this book.

Class 1: Basic Refrigera0on Cycle. October 7 & 9, 2014

MASS. MARITIME ACADEMY

Determining Real Time Performance of Residential AC Systems. Presented at the RESNET Conference San Antonio, TX February 28, 2006

EXPANSION VALVES. See Red Dot Catalog Also. * 2 ton valves - all other valves are 1 1/2 ton (1) Includes M1 Adapter 71R8050 EX02280

SECTION 8 AIR SOURCE HEAT PUMPS UNIT 43 AIR SOURCE HEAT PUMPS

A Treatise on Liquid Subcooling

AIR CONDITIONING. Carrier Corporation 2002 Cat. No

Installation Manual BCS2000/3000

SEVEN STEPS TO EFFECTIVE PRE- SEASON COOLING CHECKUPS

Refrigeration Basics from a Brewery Perspective

B. A. T. Basic Appliance Training

Fundamentals of Refrigeration Part 2 Refrigeration 1

10/4/2013. The Changing State of Refrigerants

HVAC Service Technicians Training Center

Installation Manual BCS 1000/1500

G&F Manufacturing Service Manual Version 2.0 April 2010

Section 1: Theory of Heat Unit 3: Refrigeration and Refrigerants

Technical Development Program. COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler

Air Conditioning Components

Published by the California Building Performance Contractors Association

Often fellow technicians, co-workers and field personnel CHARGE REFRIGERANT DETERMINING PROPER SYSTEM

Math. The latent heat of fusion for water is 144 BTU s Per Lb. The latent heat of vaporization for water is 970 Btu s per Lb.

Motor Vehicle Air Conditioning (MVAC) System operation and the refrigerant cycle

Calhoon MEBA Engineering School. Study Guide for Proficiency Testing Refrigeration

Vehicle Level Heating and Air Conditioning Description and Operation A/C System - Manual. A/C System - Manual

Technical Bulletin (TB-0037)

THERMOSTATIC EXPANSION VALVES Part 2

SECTION 2 SAFETY, TOOLS AND EQUIPMENT, SHOP PRACTICES UNIT 10 SYSTEM CHARGING

Service Step by Step Trouble-Shooting Check-List

UNITED STATES MARINE CORPS ENGINEER EQUIPMENT INSTRUCTION COMPANY MARINE CORPS DETACHMENT 686 MINNESOTA AVE FORT LEONARD WOOD, MISSOURI

Refrigeration/Troubleshooting Manual

Figure 17-1 Residential air conditioner (Image courtesy of Bryant Heating & Cooling Systems)

SERVICE ASSISTANT OVERVIEW FDSI Online Training

Thomas J Kelly. Fundamentals of Refrigeration. Sr. Engineering Instructor Carrier Corporation. August 20, Page number: 1.

Instruction Manual DIGITAL MANIFOLD FOR HVAC/R SYSTEMS

Electrical Problems. Fuse(s) blow or circuit breaker trips. Does the unit use circuit breakers or fuses? Replace with correct fuse(s)

DEALER SERVICE BULLETIN

What Is Liquid Subcooling?

INSTRUCTION MANUAL 4-WAY BALL VALVE Digital Manifold

THERMOSTATIC EXPANSION VALVES Part 1

Mortex INSTALLATION INSTRUCTIONS AIR CONDITIONING & HEAT PUMP INDOOR COILS

CAUTION. Check Equipment and Job Site. Clearance Requirements. Unpack Unit

DAVE DEMMA REDUCING ELECTRICAL CONSUMPTION

Application and Installation Bulletin for Master-Bilt Refrigeration Superheat Controller Kit Assembly(A ), 120/208/240/1/60, R404A, LT/MT APPS

R Series Cooling Manual

ThermoSaver TM Hot Gas Defrost System

Case 15 Refrigeration System for Chemical Fertilizer Plant Ammonia Storage

INSTALLATION AND MAINTENANCE INSTRUCTIONS 4SCU16LT Series Split System Air Conditioner WARNING

HVAC Fundamentals & Refrigeration Cycle

R.A.S.E.R.S System. Installation Guide

System Considerations for Refrigerant Blends with Temperature Glide

Head Pressure Control Valves

Installation Manual for ETI AVS Series and NON-ETI Air Handlers with SC or SD Compressor Units and R-410A Refrigerant

MYSTICOOL Max Valve System with Xstream and A.R.M.E.D. Technology Service & Installation Instructions Page 1

XSTREAM Valve System With A.R.M.E.D. Technology Service & Installation Instructions Page 1

Figure 1: Schematic of internal heat exchanger vapor-injection cycle

June 2001 / BULLETIN Way Valves. The right solenoid valve for any job.

Event #1 Brazing. In this event you will demonstrate how to:

SECTION 7 AIR CONDITIONING (COOLING) UNIT 40 TYPICAL OPERATING CONDITIONS

SECTION 7 AIR CONDITIONING (COOLING) UNIT 40 TYPICAL OPERATING CONDITIONS UNIT OBJECTIVES

Owners Manual Refrigerated Air Dryer MHT SERIES

SEA FROST BAITFREEZER 110-VOLT AIR-WATER Twin Valve

HEAT PUMPS. Carrier Corporation GT72-01 Cat. No

SECTION 5 COMMERCIAL REFRIGERATION UNIT 21 EVAPORATORS AND THE REFRIGERATION SYSTEM UNIT OBJECTIVES 3/22/2012 REFRIGERATION

Basic Principals of Air conditioning By Dr. Esam Mejbil Abed

WCH5**4. Product Specifications

ME 410 MECHANICAL ENGINEERING SYSTEMS LABORATORY MASS & ENERGY BALANCES IN PSYCHROMETRIC PROCESSES EXPERIMENT 3

30GT FLOTRONIC AIR-COOLED CHILLERS

Performance Automotive Air Conditioning

TECHNICAL GUIDE HIGH EFFICIENCY, STANDARD ECM VERTICAL WALL MOUNT AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: EWX*18-36

INSTALLATION INSTRUCTIONS HOT GAS BYPASS SYSTEM DESIGN MANUAL

A/C-HEATER SYSTEM - MANUAL

Installation Instructions

WineZone Ceiling Mount Ductless Split 15

Installation Instructions

Eclipse Technical Training CME686 CME810 CP686 CP886 CP1086

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS UNIT OBJECTIVES UNIT OBJECTIVES 3/22/2012

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

Transcription:

How to Diagnose a TXV Failurek There has been much written and many jokes made about the misdiagnosis of TXV (Thermostatic expansion valves) and rightly so. This article will cut straight to the point to help those of you who may still need a bit of clarification and hopefully, we will save the lives of a few TXVs and the pocketbooks of some customers.

Q: What is a TXV? A: A TXV (TEV) is a type of metering device. The metering device s job is to create a pressure drop from the liquid line into the evaporator which will result in refrigerant boiling (changing from liquid to vapor) through the majority of the evaporator coil. This low temperature boiling absorbs heat from the space or product being cooled. Q: How does a TXV Function? A: A TXV measures the temperature an ⴷ 㕱甀 m 愀愀瀀 res the presheat

Q: How do they fail? A: A TXV may fail either too far open or too far closed. Too far open is also called overfeeding and it means that boiling refrigerant is being fed too far through the evaporator coil, this would show up in low superheat. If the TXV fails closed it can be said to be underfeeding which means not enough boiling refrigerant is fed through the evaporator coil and superheat will be too high at the evaporator outlet. These failures can and do occur, but they are usually caused by contaminants or moisture in the system that have worked their way to the valve and are ait to stick or become restricted. Anotherare aofaaavalve failure isaaarubaoutaon bulb tube and an external equalizer without a core depressor installed on a port that has a Schrader core in place. Whenaaavalve isaoverfeedingathe firstathingatoarheck isabulb insulation, placement and strapping. If the numbing isn t properly sensing the suction line it can lead to the valve remaining too far open.

Q: Why are they misdiagnosed so often? A: TXV s are often incorrectly condemned in cases of low evaporator airflow or load. This happens because techs will find a system with low suction pressure and assume that means it is low on refrigerant. They will then start to add refrigerant and the TXV will respond by closing further the more refrigerant is added. The tech will see that the suction isn t increasing and they will conclude that the TXV is failed. This occurs because the tech is paying too much attention t suction pressure without considering the other readings. Q: What is the correct way to diagnose a TXV? A: First take all of your refrigerant readings as well as your liquid line and suction temperature at both ends. This means superheat, subcooling, suction saturation (evaporator coil

temp) and liquid saturation (condensing temp). For a TXV to do what it is supposed to you need a full line of liquid before the TXV, this means you need at least 1 of subcooling in theory but in reality, you will want to make sure that you have the factory specified subcooling which is usually around 10. In refrigeration, we do this same thing by looking for a clear sight glass. On a split system checking the subcool outside and then confirming there is no big temperature difference inside to out is a great way to ensure that kinked lines or plugged line driers aren t an issue. The next thing that a TXV needs is enough liquid pressure to have the required pressure differential. This amount of required pressure differential will vary a bit based on the valve but usually, we want to see a 100 PSI minimum difference between the liquid line pressure and the desired evaporator pressure. If the head pressure drops too low due to low ambient conditions this can come into play and impact the ability of the valve to do its job. Once this is all confirmed then it is simply a matter of checking the superheat at the end of the evaporator. Most A/C systems will be maintaining 6-14 of superheat at the evaporator outlet. If it is in that range then the valve isn t bad, it s doing its job. If it is lower than 6 of superheat at the evap outlet then it could be overfeeding (double check your thermometer and gauges) and if the superheat is well above 14 at the evaporator outlet, with the proper subcool and liquid pressure entering then you have a failed closed (underfeeding valve). Keep in mind that some valves will have a screen right before the valve and this can be the cause of the restriction rather than the valve. You can intentionally freeze the coil and try to see the freezing point or use thermal imaging to help spot if it s the valve or the screen. When you find the point of temperature you find the point of pressure drop, just remember that the TXV is DESIGNED to provide a pressure to maintain a

set superheat.