Chapter 7 Troubleshooting

Similar documents
Chapter 8 Troubleshooting

Chapter 8 Troubleshooting

Daily maintenance and checks

Thermal Shock Chambers TSA Series

Chapter 7 Checks and Maintenance

Thermal Shock Chamber TSE 11

Compact Ultra Low Temperature Chamber

Performance. TCC-150 provides uniform temperature load, and highlyrepeatable temperature change rate. Conformity to JEDEC JESD22-A104-B standard test

Faster Temperature (& Humidity) Chamber

Chapter 5 Inspection and maintenance

Operating Functions Temperature Parameters

Elmatik AS, Türi 9, Tallinn Estonia tel tel fax

SPECIFICATIONS for AIR CONDITIONING CONTROLLER ZONE CONTROL

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA

4. ALIGNMENT AND ADJUSTMENTS

Utility. High performance by special glass. Supports high-temperature, high-humidity testing

Liquid to Liquid Thermal Shock Chamber TSB 21 TSB 51

Chapter 5 Checks and Maintenance

Trouble Shooting Guide FAA, 3-phase (D3631)

Elmatik AS, Türi 9, Tallinn Estonia tel tel fax

Trouble Shooting Guide PWA, 3-phase (D10571)

4. Alignment and Adjustments

Electrical Problems. Fuse(s) blow or circuit breaker trips. Does the unit use circuit breakers or fuses? Replace with correct fuse(s)

Trouble Shooting Guide RAA, 1-phase (D3627)

Trouble Shooting Guide PAA, 1-phase (D3731)

Installation Instructions / User s Manual TSTAT0406 and TSTAT0408

Elmatik AS, Türi 9, Tallinn Estonia tel tel fax

OWNER S MANUAL HIGH WALL INVERTER. (English) (BSHVD1S SERIES)

KSD-35 DR11 KUE-35 DVN11

Instructions manual DEHUMID HP50

INSTALLATION AND USER MANUAL

Series of all-purpose physical and chemical environmental cabinets meeting the diverse needs of laboratories and research facilities.

KTIR AIR CONDITIONER SERIES TROUBLESHOOTING

- 1 - Updated on 18 March, 2010

- 1 - Updated on 18 March, 2010

Chapter 5 Inspection and maintenance

Environmental Stress Chamber AR series

Freightliner Refrigerator Troubleshooting Guide For (TJ18F) (TJ22F) (TJ18FP3)

OWNER S MANUAL HIGH WALL INVERTER. (English) (MSHVD1S SERIES)

SPECIFICATIONS Power Requirements: V, 9.5A, 60Hz V, 5.8A, 50Hz Including 2A for internal convenience outlet.

Operation Manual (Version 1.5.1)

Owner s Manual Super-Slim Four-Way Cassette

Owner s Manual. Middle Static Pressure Duct Type MEU-18MPH2 MEU-24MPH2 MEU-36MPL2 MEU-48MPL2 MIDDLE STATIC PRESSURE DUCT TYPE AIR CONDITIONER

Tempco Part Number PCT30006 Temperature Control Enclosure with Relay Output for Tote Tank Heating Applications

Part 3 Troubleshooting

(PD[ $LU 'U\HU 5 ( ) 5, * ( 5 $ 7 ( ' 7 < 3 ( & ( 6 6 ( ' $, 5 ' 5 < ( 5 6 ('5&) ದ ('5&) Instructions Manual

Faster Temperature (& Humidity) Chamber

Thermal Shock Chambers

DUCTED AIR CONDITIONER. Owner s Manual. KD Series KD24. Kaden Owner s Manual 1

PR-L2466W- PA. Operating Instructions. High Performance Refrigerator PR-L2466W-PA

Thermal Shock Chambers

Platinous. temperature. and humidity. chambers. Top Quality Design. With an Easy-to-use. Touch-Screen. Programmer

RSES Technical Institute Training Manual 2 72 hours, 72 NATE CEHs, 7.2 CEUs

POLAR TEMP FARM MORTALITY UNIT OPERATION MANUAL

π H-6621 INDUSTRIAL DEHUMIDIFIER WARNINGS SPECIFICATIONS uline.com WATER REMOVAL ELECTRICAL REQUIREMENTS BUILT-IN ELECTRICAL SAFETY

Operation Manual. (Version 1.5.1)

THERMAPHASE INSTALLATION AND OPERATING INSTRUCTIONS

Tempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications

TABLE OF CONTENTS FOR YOUR SAFETY

Refrigeration System with a Capillary Tube and a Thermostat

NO. 15FD-742 ISSUED: AUG. 10, 2007 REVISED: SEP. 30, 2013 HOSHIZAKI SELF-CONTAINED CRESCENT CUBER KM-30A KM-35A KM-50A KM-75A MODEL SERVICE MANUAL

53 KNL / 53 QNL OWNER S MANUAL

TCW 2000 Ice liner refrigerator and freezer PIJ

Service Manual & Installation Manual

User instructions DHP-AT

A/C-HEATER SYSTEM - MANUAL

Fast Track Troubleshooting

INSTRUCTION MANUAL (UNIT APPEARANCE MAY VARY FROM IMAGE) BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS.

REFRIGERATOR SAFETY. Your safety and the safety of others are very important.

Wine Cooler. Model No. MCWC16MCG MCWC30MCG. CAUTION: Read and follow all safety rules and operating instructions before first use of this product.

Technicians Manual Single Compressor

Polar Air Dryer. Instructions Manual PDRCF PDRCF R E F R I G E R A T E D T Y P E C O M P R E S S E D A I R D R Y E R S

User Manual

Troubleshooting & Reference

DC50X2 Models 50 Pound Stacked Commercial Dryer. Troubleshooting,Fault Codes, and Schematics. Starting serial number Part # /13

Tissue-Tek TEC Plus Cryo Console OPERATING MANUAL

TABLE OF CONTENTS REFRIGERATOR-FREEZER. Model No. NR-BN34FX1 Model No. NR-BN34FW1

Model:DKG610(V)/650(V) Model:DKG810(V)/850(V)

ARTIFICIAL INTELLIGENCE TEMPERATURE CONTROLLER

Double Door Over 70. Service Manual. Models: F NMTZH 821 F T F NMTZH 822 F T

DEHUMIDIFIER INSTRUCTION MANUAL

Table of Contents. Service Procedures. Service Procedures. Measuring Superheat (4) Measuring Subcooling (5) Airflow Calculation (6-8)

TEMPERATURE CONTROL MODULE MODEL R3-TC2

SPLIT TYPE ROOM AIR CONDITIONER. WALL MOUNTEDtype INVERTER. Models Indoor unit Outdoor unit AOU 9RLFW1 AOU12RLFW1 ASU 9RLF1 ASU12RLF1 R410A

SERVICE MANUAL FOR MODEL RM-49

Model No. GB-PAC-08E4. 8,000 BTU Portable Air Conditioner Operating Instructions

UNDERCOUNTER LABORATORY REFRIGERATORS and FREEZERS Installation, Operation and Maintenance Instructions

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 870 SERIES INDUSTRIAL CONTROL PANELS

Container Refrigeration

MANUAL FOR AIR COOLED INDUSTRIAL CHILLERS MODEL: UCS-10A

User Manual. Commercial Chest Freezer User s Manual 360CF5, 360CF8, 360CF14, 360CF18

Instruction Manual. Refrigerated Air Dryer

User Manual. Commercial Reach-In Refrigerators: RF-1D, RF-2D, RF-3D. Commercial Reach-In Freezers: FZ-1D, FZ-2D

JBL2088HES JBL2088HES0, JBR2088HES JBR2088HES0, JFC2089HEP JFC2089HEP0, JFC2089HES JFC2089HES0, JFC2089HPF JFC2089HPF0, JFC2089HPY JFC2089HPY0

CAUTION. No-Load Performance, Controls in Normal Position

SECTION 7 AIR CONDITIONING (COOLING) UNIT 41 TROUBLESHOOTING

Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes

CAREFULLY READ THESE INSTRUCTIONS BEFORE USING SAFETY PRECAUTIONS USE OF EXTENSION CORDS

INSTRUCTION MANUAL. Model Number: DX K Wine Cooler BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS.

OWNER S MANUAL. High-Wall Fan Coil Unit CONTENTS

Transcription:

Chapter 7 Troubleshooting This chapter explains equipment trouble and how to remedy it. When trouble is detected by one of the self-check features, the trouble is displayed on the instrumentation panel display and a trouble buzzer is sounded. For trouble undetected in self-checks and misoperation which can be easily mistaken as trouble, see "7.2 Before You Call for Service". This chapter also includes trouble information for options. 135

7.1 Alarm and Action DANGER ELECTRIC SHOCK! Before working on the power circuits on the primary side of the main power switch (breaker), shut OFF primary power supply and check the line is dead. Also, take measures to prevent accidental charging. Working with primary power supply ON runs the risk of electric shock. Shut OFF power from the main power switch (breaker) BEFORE detaching the electric parts compartment panel or the mechanical parts compartment panel. The TSA Series is equipped with a buzzer that sounds when trouble occurs as well as self-check features which display the trouble on the instrumentation panel display. Displayed alarm codes and their content are given in the alarm table on the following pages. Remedy trouble as described therein. For trouble which is undetected in self-checks, see "7.2 Before You Call for Service". If the trouble cannot be remedied after taking the prescribed action, contact the place of purchase or ESPEC CORP. When an Alarm Occurs The chamber will be in one of the below states when an alarm occurs. Procedure 1. When trouble occurs with the chamber or controller, the Alarm screen appears on the display. 136

2. Press an entry under Alarm Name. A screen will appear with information on the Contents, Cause and Action to be taken to remedy the trouble. 3. Try correcting the trouble as explained in the troubleshooting information. However, if instructed to call for service or if the action you take fails to remedy the problem, contact the place of purchase or ESPEC CORP. 137

Alarm Table Table 7.1 Alarm table PHASE REVERSED HI STAGE TEMP. LOW STAGE TEMP. HI STAGE DISCHARGE TEMP. LOW STAGE DISCHARGE TEMP. H-TEMP. BOX CIRCULATOR 1 FAILURE H-TEMP. BOX CIRCULATOR 2 FAILURE L-TEMP. BOX CIRCULATOR 1 FAILURE L-TEMP. BOX CIRCULATOR 2 FAILURE Reverse or misaligned phase was detected in primary (3-phase) power supply. The high stage refrigerator temperature switch or motor protector The low stage refrigerator temperature switch or motor protector A temperature outside of the specified range was detected on the temperature controller channel (Ai-10ch) that monitors the high stage compressor discharge pipe temperature. The chamber A temperature outside of the specified range was detected on the temperature controller channel (Ai-11ch) that monitors the low stage compressor discharge pipe temperature. The chamber The thermal relay of high temperature chamber circulator 1 The thermal relay of high temperature chamber circulator 2 The thermal relay of low temperature chamber circulator 1 The thermal relay of low temperature chamber circulator 2 Primary power supply is not correctly connected to the The compressor/motor may have overheated. Compressor surface temperature may have dropped. The compressor/motor may have overheated. Compressor surface temperature may have dropped. The high stage compressor discharge pipe temperature is higher than specified. Possible causes include compressor trouble, refrigeration circuit trouble, and refrigerant leak. The low stage compressor discharge pipe temperature is higher than specified. Possible causes include compressor trouble, refrigeration circuit trouble, and refrigerant leak. Set the power key in the OFF position followed by main power switch (leakage breaker). Check power supply phase and connection. within allowable ranges, there is sufficient space above/behind the chamber and power supply voltage is not fluctuating. within allowable ranges, there is sufficient space above/behind the chamber and frost does not build up on the evaporator. within allowable ranges, there is sufficient space above/behind the chamber and power supply voltage is not fluctuating. within allowable ranges, there is sufficient space above/behind the chamber and power supply voltage is not fluctuating. Cool the air circulator and resume Cool the air circulator and resume Frost buildup may have caused overload. Defrost chamber and resume Frost buildup may have caused overload. Defrost chamber and resume 138

OVERHEAT PROTECTOR TRIP OVERCOOL PROTECTOR TRIP AMB TEMP.CIRCULAT OR FAILURE TEST AREA DOOR OPEN TEST AREA DOOR OPEN TEST AREA DOOR OPEN LOW AIR SUPPLY PRESSURE AIR SUPPLY CIRCUIT DOWN WATER SUSPENSION RELAY TRIP HI STAGE PRESSURE The (operating panel) overheat protector has activated. The (operating panel) overcool protector has activated. The thermal relay of the ambinet temperature air circulator Test area door switch has Testing has been suspended. Test area door switch has Testing has not started. Test area door switch has Dry mode has not started. Air supply pressure has dropped below the specified level. The chamber is still running. Test area temperature rose above the overheat setting. Test area temperature dropped below the overcool setting. The door was opened during chamber operation. The door was opened during chamber operation. The door was opened during chamber operation. Air supply pressure may be low due to long period of disuse or air supply may be off. Air supply pressure has Air supply is OFF or supply dropped below the specified pressure is low. level without recovering. The cooling water was not Cooling water of refrigerator supplied in the water-cooled is not supplied. specification. The high stage refrigerator high/low pressure switch Condenser pressure may be high or vapor pressure low. Check to assure the setting of the overheat protector is set at least 10 C higher than the setpoint high temperature. If overshoot is greater than setting, lower the preheat temperature. resume Check to assure the setting of the overcool protector is set at least 10 C lower than setpoint low temperature. If undershoot is greater than setting, raise the precool temperature. resume resume Close door securely and press the CLR key on the ALARM screen to clear the alarm. Then, press RESUME on Operation Mode Selection screen to resume Close door securely and press the CLR key on the ALARM screen to clear the alarm. Then, press START TEST on Operation Mode Selection screen to start Close door securely and press the CLR kye on the ALARM screen to clear the alarm. Then, press DRY MODE on Operation Mode Selection screen to resume Check air supply. If an air compressor is built-in, check to see if it is running properly and pressure rises. After appropriate treatment, press the CLR key to clear the alarm. Then press the START TEST on Operation Mode Selection screen to start Check air supply. If an air compressor is built-in, check to see if it is running properly and pressure rises. If everything is OK, there may be an air leak. Call for check for cooling water supply to the refrigerator. within allowable ranges, the condenser or strainer are not clogged, and there is sufficient space above/behind the If the problem is elsewhere, set the power key in the OFF position and call for 139

LOW STAGE PRESSURE CONDENSER FAN FAILURE HI STAGE OVERCURRENT LOW STAGE OVERCURRENT H-TEMP. BOX ABS. HIGH LIMIT TEMP. L-TEMP. BOX ABS. HIGH LIMIT TEMP. L-TEMP. BOX ABS. LOW LIMIT TEMP OVERHEATING (TEST AREA) OVERCOOLING (TEST AREA) CIRCUIT BREAKER TRIP The low stage refrigerator high/low pressure switch Condenser fan thermal relay tripped because of fan overheating. The thermal relay of high stage refrigerator The thermal relay of low stage refrigerator The temperature inside the h-temp. box has risen above the absolute high limit. The temperature inside the l-temp. box has risen above the absolute high limit. The temperature inside the l-temp. box has dropped below the absolute low limit. Test area temperature rose above overheat protection alarm. Test area temperature dropped below overcool protection alarm. The circuit breaker has FROSTED OVER The evaporator is frosted over. The chamber has stopped to protect the refrigeration system. Condenser pressure may be high or vapor pressure low. The fan has overheated. The compressor/motor may be overloaded or The compressor/motor may be overloaded or air flow due to excess of specimens and inadequate damper operation due to low air pressure. air flow due to frost buildup and inadequate damper operation due to low air pressure. air flow due to excess of specimens and large undershoot due to low precool target. within allowable ranges, the condenser or strainer are not clogged, and there is sufficient space above/behind the If the problem is elsewhere, set the power key in the OFF position and call for check for condenser clogging by dust. Check ambient temperature is within allowable ranges, there is sufficient space above/behind the chamber and power supply voltage is not fluctuating. Check ambient temperature is within allowable ranges, there is sufficient space above/behind the chamber and power supply voltage is not fluctuating. Check specimen quantity and air pressure. Resume Check air pressure. Stop test for a while and defrost the Resume Check specimen quantity and precooling target. To prioritize recovery time over amount of undershoot, change overcool protection alarm setting in test pattern. Check specimen quantity and air pressure. air flow due to excess of Resume specimens and inadequate damper operation due to low air pressure. Check specimen quantity and precooling air flow due to excess of target. specimens and large To prioritize recovery time over amount of undershoot due to low undershoot, change overcool protection precool target. alarm setting in test pattern. Possible causes include errors in refrigerator, air circulator and condenser fan (air-cooled spec.). Resume Excessive frost buildup is Manually defrost the chamber, reset the preventing proper number of Defrost Cycle, or select the refrigeration operation. auto defrost mode. Defrost Cycle is not properly set or precooling lasts too long. 140

PATTERN SETTING TIME INVALID OUT OF ALLOWABLE OPE. RANGE AI-CH0 AI-CH1 AI-CH2 AI-CH3 AI-CH5 AI-CH6 AI-CH7 AI-CH8 AI-CH9 Invalid time setting was detected in the data of Pattern operation that was going to start. The execution of Pattern operation Temperature setting value outside of allowable operating range was detected in the operating data to be started. The room temperature compensation input to the Display shows [---] as process values. The test area upstream input to the The test area downstream input to the The specimen temperature input to the The chamber The H-temp. box input to the The L-temp. box input to the channel (Ai-7ch) of channel (Ai-8ch) of channel (Ai-9ch) of Invalid time setting is included in the data of Pattern operation. Temperature setting value outside of allowable operating range is included in the operating data. Check the time setting of Pattern operation data. The alarm can be cleared by pressing the CLR key on the ALARM screen to clear the alarm. If the same alarm occurs, call for call for connected to the RTD controller board or RTD (100 ohm) is an open or short circuit on the SCP-220 board. connected to the TD connected to the TD connected to the Ai-3 connected to the Ai-5 connected to the Ai-6 connected to the Ai-7 connected to the Ai-8 connected to the Ai-9 terminal on the SCP-221 141

AI-CH10 AI-CH11 COMMUNICATIO N 1 COMMUNICATIO N 2 STT EXPOSURE TIME (WARNING) 1 2 OVERHEATING channel (Ai-10ch) of The chamber channel (Ai-11ch) of The chamber The instrumentation detected communication trouble between the CPU board and display board. The instrumentation detected communication trouble between the display board and temperature controlling unit. With STT ON, specimen temperature did not reach the set point within the forced step shift time, so the process has shifted to the next exposure. Disconnection of the specimen temperature input to the detected. The chamber is continuing the test using the remaining specimen temperature input. Disconnection of the specimen temperature input to the detected. The chamber is continuing the test using the remaining specimen temperature input. Disconnection of all specimen temperature inputs to the controllers was detected. The chamber is continuing the test. The specimen overheat alarm The chamber connected to the Ai-10 terminal on the SCP-221 connected to the Ai-11 terminal on the SCP-221 Communication error between the CPU board and display board. Communication error between the display board and temperature controlling unit. Too many specimens are loaded resulting in longer time to reach the set point or exposure shift time is set too short. connected to the Ai-3 (ANALOG) controller, there is connected thermocouple, or the specimen temperature input connector is not connected to the terminal correctly. connected to the Ai-4 (ANALOG) controller, there is connected thermocouple, or the specimen temperature input connector is not connected to the terminal correctly. The specimen temperature input connectors are not connected to the terminals correctly. air flow due to an excess of specimens, overshoot due to a high preheat temperature, and inadequate damper operation due to low air pressure. If the same alarm occurs again, call for If the same alarm occurs again, call for Set the main power switch OFF and ON to resume Set the main power switch OFF and ON to resume Check the specimens and the set point. Press CLR on the ALARM screen to clear the alarm. After stopping operation, check connection of the specimen temperature measuring thermocouple and the specimen temperature input connector. Press the POWER key to turn power to the instrumentation OFF and resume After stopping operation, check connection of the specimen temperature measuring thermocouple and the specimen temperature input connector. Press the POWER key to turn power to the instrumentation OFF and resume Check connection of the specimen temperature input connector and the specimen temperature sensor setting of 'Sensor Offset / Setting.' Press the POWER key to clear the alarm and resume Check specimen quantity, preheat temperature and air pressure. 142

OVERCOOLING OFF OFF Shortage of cooling water The specimen overcool alarm The chamber All specimen temperature inputs used for the test were Testing All specimen temperature sensors are set to OFF. Testing Disconnection of all specimen temperature inputs to the controllers was detected. The chamber is continuing the test. air flow due to an excess of specimens, overshoot due to a high precool temperature, and inadequate damper operation due to low air pressure. The specimen temperature input connector is not connected to the terminal correctly or there is no valid specimen temperature sensor. All specimen temperature sensors are set to OFF. The specimen temperature input connectors are not connected to the terminals correctly. All specimen temperature All specimen temperature sensors are set to OFF. The sensors are set to OFF. chamber is continuing the test. Cooling capacity (condenser) is trouble. Continuous operation may cause damage on the Shortage of cooling water or water temperature of cooling water is too high. Check specimen quantity, precool temperature and air pressure. Check connection of the specimen temperature input connector and the specimen temperature sensor setting of 'Sensor Offset / Setting.' Press the POWER key to turn power to the instrumentation OFF and resume Check the specimen temperature sensor setting of 'Sensor Offset / Setting.' Press the POWER key to turn power to the instrumentation OFF and resume Check connection of the specimen temperature input connectors. Press CLR on the ALARM screen to clear the alarm. Check the specimen temperature sensor setting of 'Sensor Offset / Setting.' Press the CLR on the ALARM screen to clear the alarm. If the same alarm occurs again, call for Remedial action: Press the POWER key to turn off. clean the strainer to have enough water supply. If the same alarm occurs again after remedial action, call for 143