Pipo Communications. Model ST-888. DTMF ANI/ENI Display Decoder

Similar documents
ALARM SYSTEM USER S MANUAL Rev

MODEL ZAC ZONE ANNUNCIATOR/CONTROLLER DESIGNED FOR ZONE ANNUNCIATION AND MONITORING

HRX Technical Manual. Version 1.2

Mark 25 Ultrapure Water Conductivity Analyzer

Model RC-10 INSTRUCTION MANUAL

OPERATOR S MANUAL MODEL AP15/AP15-1/AP15-2 PC-ALARM PANEL

A1UL PERS. Personal Emergency Response System. For Technical Support Please Contact Your Service Provider Or Distributor

Elite 64 Version 64 Zone Controller Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand

USER MANUAL FOR OPERATING SYSTEM

Table of Contents SECTION PAGE

Alarm Tone Generator Model AG17

ProTalk. Expander. Operating Manual Model B1292. July 28, 2009 Rev. 1.01

The Challenger Version 8 User Guide

Elite 16D Version 16 Zone Controller Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand

3226 Trunk Port FXO Doorphone

AGRI-ALERT 9600 ALARM SYSTEM USER MANUAL

1126 Series Ceiling Mount PIR Motion Detector

Operating instructions 2-channel code lock. Item No

ADE Gen4. Speech Dialler Engineering Information. Description. Features

Installation Instructions. Fire Command Center/Fire Alarm Annunciators D1256/D1257

PERS-3600 PERSONAL EMERGENCY REPORTING SYSTEM INSTALLATION & OPERATION INSTRUCTIONS

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE

MAMI MULTI BASE STATION

Refrigerator/Freezer Guard Models VM605, VM605E. Property Guard Models VM610, VM610E. Temperature Monitor and Alarm

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

Installation and ZONES: Operation Manual. Model: ON STI-34108

Operating instructions SENTRI4 Control panel based Fire detection and alarm system

Voice Board. Installation and Programming Guide. Runner 4/8,PowerWave 4/8/16 &, Elite64. Add-on Board For Storing Recorded Voice Messages

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

UNC100 Integra Manual

OPERATION MANUAL MODEL LC2000 COPYRIGHT 2017 PNEUMERCATOR CO., INC EXPRESSWAY DRIVE NORTH HAUPPAUGE, NY 11788

Long Range Radio Alarm Transmitter

P2267 NETWORK INTERFACE

Computer Room Guard Model VM Manual and Installation Instructions

ETSA380MF SHOWN WARNING. shall be used ONLY on approved vehicles. It is the sole responsibility of the user of these devices to ensure compliance.

GSM SMS Controller GSM SMS Alarm Unit S130 S140 S150. User Manual

TECHNICAL. Add Time Controlled Alert Tones and Emergency Tones to Your Paging System CTG-1. Clock Controlled Tone Generator

EnviroCom I Desktop Environmental Monitoring System Owner's Manual

Section 9 System Operation

Control Panel. 1.0 GENERAL SCOPE OF WORK Introduction... 2

Long Range Radio Alarm Transmitter

SC-F3G User Manual 1.0

TrueCom. Building Communications Systems 5115-Series , Area of Rescue Communications System. Description

Long Range Radio Alarm Transmitter

OUT TO WALLJACK. Input

AUTOMATION. Operator s Manual RST Series Web Enabled Input Module. Rev. A2, 1/12

PTE0705 Electric Fence Monitor

8VHU*XLGH K4254V3 6/01

Preface. Thank you for purchasing our GSM Security Alarm System ( The System )! The System will keep your home and property safe around the clock.

Any additional devices linked to the system ET08 (computer, sensors, relays etc.) must be approved by LST EN standard.

GSM RFID VOICE Alarm System

D1255RB/D1256RB/D1257RB

DS9400 Series. Release Notes for Firmware V2.07. Fire Alarm Control Panel

1. Introduction. 2. Product overview

Agri-Alert 800EZe. Alarm System. Alarm. System in Standby. Burglary Armed. Online (phone) Green = zone activated Amber = zone bypassed.

Table of Contents SECTION PAGE SECTION 1 INTRODUCTION Description Features Models... SECTION 2 RS-232 COMMUNICATIONS...

ZX1e ZX2e ZX5e. Document No Issue 01 user manual

Alarm Panel [ PRELIMINARY HARDWARE MANUAL ] USER MANUAL. v1.0a. May 7, 2008 D-OC-UM

AVCOM System Installation Instructions

FL500 Modbus Communication Operating Manual. Order No.: /00. MSAsafety.com

FI6000 INSTRUCTION MANUAL. Thank you for choosing another quality product from Amperes Electronics. Fire Alarm Interface

READ ME FIRST DIY WIRELESS ALERT. Driveway Alert Kit. Instruction Manual

Thank you for choosing Ideal Security s Home Security System with Telephone Dialer.

VDS2510 Installation Manual

Figure 1. Proper Method of Holding the ToolStick. Figure 2. Improper Method of Holding the ToolStick

Instructions manual. By-alarm. By-alarm Manager software

Fire Command Keypad. XR5 User s Guide

VPS3 Installation Manual

Contents. Glossary

P1195 DUAL TOURNIQUET MONITOR

Multi-Graphic MCPB & Series 115B, 2223R, & 2233R

All-In-One Wireless Security System V3.2 Programming Guide. Model # MG6130 / MG6160

Instruction Manual Model Backup Switch, 1 for 8

The Kryos LN2 Liquid Level Control & Cryogenic Temperature Control

Wireless Keypads LKP(E)S8M Series

ENGINE MONITOR VOTT MODEL: YEAR WARRANTY

Installation and Operation Manual. Model: STI TRIGGERED OUTPUT PLUG 12VDC, 75mA, 3 SEC. EMBOSSED PROGRAMMING

Installation & Operation Manual March 2017 Rev. 4.1

Powerwave Series. Technical Manual

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

User s Guide. CN616 Series 1 4 DIN Economical 6-Zone PID Temperature Controllers. Shop online at omega.com SM

Crypto-Lock. Model CC-8521B Updated 7/17. Access Control System. MONITEQ, Inc. INSTRUCTION MANUAL

External Wireless Sounder

HRX3000. Technical Manual

Fire detection and alarm system Operating instructions

Agri-Alert 800 EZe Alarm System Owner s manual

Solution-16/ Solution-16 Safecom Installation Manual ISSUE 2.10

NookBox Installation Guide Keypad. Installation Guide. NookBox Keypad (P / E )

TECHNICAL. Voice Alarm Dialing or Store Caster Announcements from up to Eight Inputs. K-2000-DVA Multi-Input Voice Dialer/Announcer

PERMACONN PM1030 Includes DI300. Installation Manual

Static Pressure Control

EIA-232D Protocol And Data Formats for the AFP-200 Fire Alarm Control Panel

_5120_School_Intercom_Rack_Spec.doc 09/21/04

Independent Zone Control (I.Z.C.)

ICP-CC488 ICP-CC488 EN. Control Panel. User s Guide

Advantium 16 System Monitor

To activate using remote control: press [ ] key once. To activate using keyboard: on panel keyboard [ ] keys once.

ACCURATE ELECTRONICS INC PO BOX SW HALL BLVD BEAVERTON OR USA FAX

BID SPECIFICATIONS FOR (NAME OF ENTITY) COMMUNITY OUTDOOR WARNING SIRENS

STORM PRO Model # - C-4014, C Storm Pro- Instruction Manual V.2. This instruction manual serves as a guide for the Storm Pro.

Transcription:

Pipo Communications Model ST-888 DTMF ANI/ENI Display Decoder 1516 Cassil Place Hollywood, California 90028-7106 Phone: 323-466-5444 Fax: 323-466-1520 www.pipo.cc Manual # 68-9888 May 1, 2002 Rev. 5/02 DESCRIPTION The ST-888 Mobilecall Display Decoder is a desktop console for use in DTMF Automatic Number Identification (ANI) and Emergency Number Identification (ENI) applications. It is designed for installation at a dispatch office or other control point to decode and display incoming identification signals from mobile and other units equipped with Pipo Communications Model ST- 804A or similar ANI encoders. During normal operation, an encoded message is transmitted every the mobile operator keys the radio microphone. The message (or sequence) contains the identification (ID) number of the transmitter. Upon receipt at the dispatch office or control point, the ST-888 decodes the message and displays it on a numerical read-out for positive identification of the sending unit without the need for voice call signs. The ST-888 can be used with a variety of DTMF digit rates and message lengths. All setup and configuration requirements for the ST-888 are handled via a serial I/O port of a PC using Selectone s Product Manager, a Microsoft Windows based program. The ST-888 also has a parallel output port to drive a printer. Incoming messages from sending units may be printed along with the date and of receipt. If the incoming sequence is an alarm report (ENI sequence), the word ALARM is added to the printout. The ST-888 may be operated with almost any power supply within the operating voltage specification range. Because of our comprehensive warranty policy, you should not have to consider field repair. However, if repair is unavoidable, all parts are clearly identified in the board diagram and circuit schematic. Most parts used in the ST-888 are readily available through local component distributors. SETUP AND CONFIGURATION Before operation is possible all operating parameters must be configured through Selectone Program Manager, available in both Windows and DOS versions. Setup and configuration details are documented in the HELP area of this program. Though setup and configuration involves the most detailed documentation for this product, it is quite probable that it may only be used OPERATING SPECIFICATIONS PARAMETER SPECIFICATION Operating Voltage:... 13.6Vdc ± 20% Operating Current:... <50mAdc at all operating voltages Signalling Format:... DTMF (16 available characters) Sequence Length:... ANI or ENI prefix plus 1 to 8 ID digits Signalling Input Level:... 30mVrms to 2.5Vrms (composite) Twist Acceptance:... -8 to +4 db if lesser tone is > 30mVrms Noise Tolerance:... -12dB referenced to lower amplitude tone Decode Bandwidth:... ± 2.3% of nominal DTMF frequency Signalling Input Impedance:... >50K balanced Digital Rate: Manual:... 0.5 to 10 Digits/Sec. 80mS min. tone on 5 Digits/Sec.:... 4 to 10 Digits/Sec. 80mS min. tone on 10 Digits/Sec.:... 8 to 16 Digits/Sec. 45mS min. tone on 15 Digits/Sec.:... 11 to 20 Digits/Sec. 30mS min. tone on 20 Digits/Sec.:... 14 to 22 Digits/Sec. 25mS min. tone on Speaker Mute:... Form C Relay Energizes on receipt of DTMF Alarm Output:... Open collector Serial Port:... Standard RD-232C configured for DCE Serial Baud Rate:... 1200 baud, 8 bits 1 stop bit, no parity Dimensions:... 80 W x 4.3 D x 1.7 H 20.32cm x 10.92cm x 4.32cm Specifications are subject to change without notice. once in the product life. Using the HELP area as the primary documentation vehicle insures prompt availability of corrections or updates. After the initial purchase, updates are available at no charge via Pipo Communications web site at www.pipo.cc. OPERATION When power is applied to the ST-888, the version of the firmware is displayed for four seconds. If the MEMORY RECALL switch is pressed during the the version is displayed, the serial number of the unit is displayed. This information should be available if it is necessary to call Selectone for technical assistance.

If the lithium cell for the of day clock is low, LO CELL is displayed instead of the version of the firmware and the sounder is activated for four seconds. The ST- 888 will operate normally but printout of the and date may be incorrect. The lithium cell, BT1, should be replaced and, if necessary, the and date set using the Program Manager software. Replacement lithium cells may be ordered from Selectone but it is a standard CR2032 coin cell which should be readily available locally. NOTE: When a printer is connected to the model ST- 888, observe the following precautions: Always apply power to the ST-888 before applying power to the printer. If power is applied to the printer before the ST-888, the ST-888 will not initialize properly and will be inoperative. If this occurs, restore normal operation by preforming the following steps in the order shown: 1. Remove power from both the printer and the ST-888. 2. Apply power to the ST-888. 3. Apply power to the printer after power is applied to the ST-888. ANI - AUTOMATIC NUMBER IDENTIFICATION When the ST-888 receives an ANI sequence from a mobile unit equipped with a DTMF ANI encoder such as the ST-804, it decodes the sequence and displays it as the sending unit s identification number. The internal sounder will be heard momentarily, if enabled. Incoming ANI sequences are evaluated for speed and sequence length. Sequences may be sent manually or automatically with speeds ranging from less than 1 digit per second for manual encoders to 20 digits per second for automatic encoders. Sequence lengths may be two to eight digits in length, not counting the start prefix digit. Both speed and sequence length must be selected during configuration. Automatically sent sequences will be rejected if they contain more or less digits than the programmed length. When in the Manual Data Rate, sequences must contain at least the number of digits programmed as the sequence length to be accepted, but they are not rejected if they are over length. Instead, digits received after the selected sequence length are ignored. Only the characters received after the start prefix are displayed. The configuration of the unit determines whether each ANI sequence continues to be displayed until replaced by a new sequence, or blanks after the period selected during configuration. ENI - EMERGENCY NUMBER IDENTIFICATION ENI sequences follow the same validation requirements as an ANI sequence. When an alarm sequence is received, the display flashes to indicate that it is an alarm sequence on display. Display blanking, if enabled, does not blank the display. The internal buzzer and external alarm, if used, sound and the unit will not accept normal ANI sequences until manually reset. If a printer is connected to the ST-888, the alarm sequence printout will include the word ALARM after the date. ALARM RESET After receipt of an alarm report, pressing the ALARM RESET switch on the front panel returns the unit to normal operation. If a printer is used, ALARM RESET and the and date is printed. If a second alarm sequence is received before the first has been reset, the first is pushed into the memory stack and the new one is displayed. When the alarm is reset, the buzzer sounds at twice the previous rate (one quarter second on, one quarter second off) to indicate that one or more alarms in the memory stack were not acknowledged by resetting. Pressing the ALARM RESET switch a second silences the buzzer (this causes a TIME message to be printed, if a printer is used). ANI/ENI MEMORY AND RECALL Whenever a displayed sequence is replaced by a new sequence, it is moved into the memory storage stack. The memory capacity is eight sequences, not including the most recent sequence which is on display. When the memory is full (i.e., eight sequences have been stored), a new sequence pushes the FIRST-IN (or oldest) sequence out of memory, and each sequence steps down one position with the LAST-IN (or newest) being the first sequence in the memory stack. Pressing the MEMORY RECALL switch, then releasing it scans through the memory. Each the switch is pressed and released, the next sequence in memory will be displayed, starting with the last in. The entire memory may be examined with return to the real- display by pressing the switch one more. Alarm messages stored in memory will flash when displayed. During memory display, a decimal point is added to the display at the far left. The decimal is a counter to indicate the position of the sequence in memory. The last-in sequence is indicated with the decimal at the far left. Each the switch is pressed the decimal moves progressively to the right with the first-in (oldest) sequence indicated by the decimal at the right. The decimal blanks out when the display returns to the real- display. A pause of five seconds or more between pressing the MEMORY RECALL switch will cause the memory display to out and the unit will return to the real- display. A new ANI sequence received while scanning the memory immediately returns the unit to real-, and the new ANI sequence will be 2

displayed. TIME OF DAY The clock setting can be checked at any by pressing and holding the ALARM RESET switch when the internal alarm buzzer is not active. The will be displayed in 12-hour or 24-hour format on the ST-888. If the unit is set for 12-hour format, the leftmost decimal point indicates PM. The printer, if used, will print TIME [ date]. This can be used as an event marker and annotated as appropriate. If the ALARM RESET switch is pressed while the leftmost decimal point is on, the of day clock is retarded to the previous minute. (Example, if the clock is at 09:45:40, it will go to 09:45:00. If the ALARM RESET is pressed while the second decimal point from the left is on, the of day clock is advanced next minute. (Example, if the clock is 09:45:40, it will go to 09:45:59. If the ALARM RESET switch is pressed while the third decimal point from the left is on, the of day clock is retarded by one hour. This function is disabled in the hour between midnight and 1 AM to prevent corrupting the date. If the ALARM RESET switch is pressed while the fourth decimal point from the left is on, the of day clock is advanced by one hour. This function is disabled in the hour between 11 PM and midnight to prevent corrupting the date. ELECTRICAL INTERFACE The following section describes all wires on the interface cable for the ST-888. The connector pin numbers are shown in brackets [] and the wire colors are shown in parentheses (). [1] (BROWN) Negative (-) Supply GND. [9] (LIGHT BLUE) (-) Supply GND [2] (RED) Signalling audio input balanced input. Connect to GND for unbalanced input. [10] (PURPLE) Signalling audio input [3] (ORANGE) Not used [11] (GRAY) (-) Supply GND [4] (PINK) External alarm. Open collector saturates to (- ) supply during alarm condition. [12] (WHITE) Receiver mute relay N.O. For speaker muting during ANI/ENI sequences. [5] (YELLOW) Receiver mute relay N.C. For speaker muting during ANI/ENI sequences. [13] (BLACK) Receiver mute relay common. For speaker muting during ANI/ENI sequences. [6] (DARK GREEN) (-) Supply GND [14] (BROWN/BLACK) Not used [7] (LIGHT GREEN) Not used [15] (RED/BLACK) (+) Supply 13.6 Vdc [8] (DARK BLUE) (+) Supply 13.6 Vdc ± 20% Note: The /date function in the ST-888 is Y2K compatible. TEST MODE If both the MEMORY RECALL and ALARM RESET switches are pressed for 4 seconds, the unit will enter the test mode. While in test mode the unit will display every DTMF digit as it is received. While in test mode, all other functions are disabled. To exit test mode and return to normal operation, again press both switches for four seconds. NOTE: Test mode is for system trouble shooting only. No timing or sequence length checking is done so the unit is prone to false detection of digits. INSTALLATION Interface to the host radio equipment is made using a supplied cable connected to the DB15 RADIO INTER- FACE CONNECTOR on the rear of the ST-888. The following table details the connector pinout, and connections. Contact Pipo Communications for additional details. WARRANTY POLICY All of Pipo Communications products are guaranteed to meet or exceed published performance specifications and are warranted against defects in material and workmanship for a period of two (2) years from date of purchase. Third party equipment such as radios, power supplies, antennas, etc., carry the factory warranty of their respective manufacturers. All warranty repairs must be performed by Pipo Communications. Any unauthorized repair attempted by the customer, alteration or modification of the equipment, damage by external sources, or removal or alteration of the serial number label or date code, will void the warranty. Specifically excluded from this warranty are batteries, fuses, lamps, and damage caused by lightning, power surges, or mechanical abuse. Equipment for repair may be returned to the factory without prior written authorization; however, a note must be sent with the packing list briefly describing the nature of the defect. Repairs must be shipped freight prepaid and will be returned freight prepaid. Shipments should be directed to: 3 Pipo Communications Attn: Repair Department 1516 Cassil Place Hollywood, California 90028-7106

Schematic - ST-888 Display Decoder

Schematic - ST-888 Display Decoder

ST-888 Component Locator Pipo Communications 1516 Cassil Place - Hollywood, CA 90028-7106 - U.S.A. Phone: 323-466-5444 - Fax: 323-466-1520 www.pipo.cc