Wireless Smart Metering LAN-WMBUS-M. Wireless MBUS, door and window sensor. With optional glass break accessory.

Similar documents
Smart Wireless Devices LAN-WMBUS-M. Wireless MBUS, door and window sensor. With optional glass break accessory.

RAE Systems. Using the MeshGuard. Protection Through Detection

USER MANUAL COMBOX.L ATEX. Long Range Low Power Wireless Logger For The High-Risk ATEX Conditions

Universal Sensor. Installation Guide. t: f: e: w: uk.tunstall.com Version: V2.97 (421V0R1.

User manual. ABB i-bus EIB. Zone Terminal MT/S Intelligent Installation System ABB STOTZ-KONTAKT

SonoSelect and SonoSafe Energy Meters

WIRELESS NETWORK USER MANUAL MHz RFT-868-PIR Wireless Passive Infrared Sensor

GSM RFID VOICE Alarm System

Smart Wireless Sensor

Badge Reader BR Installation Guidelines. Product Summary

E529 Smart Digital Thermostat Product Guide

KNX module for smoke alarm devices Dual/VdS and Q-Label (Order no )

Smartphone Application Development Guide for BatteryMole Bluetooth Battery Monitoring System for Automobiles (BMBT)

1117RX Series - 8 & 16 Zone Wireless 868MHz Radio Duress/Panic Alarm System For Bank Santander Branches

Added password for IP setup page : Password must be in IP format!

SmartDial. Wireless. User Manual. -en_gb language A004. Document in original

A1UL PERS. Personal Emergency Response System. For Technical Support Please Contact Your Service Provider Or Distributor

MAMI MULTI BASE STATION

1126 Series Ceiling Mount PIR Motion Detector

Modbus TCP/IP Option Instruction Manual

CU-IQ MANUAL 1. DESCRIPTION Radio Control Panel CU-IQ

Telemetry Communications Device. Installation Guide. Interface for the Emizon managed network. Issue 1: February 2008

Options Specification

Consultant Specification AGILE Wireless Fire Detection System

ATS1235 Advanced Wireless DGP on 868 MHz AM Installation Sheet

Smart Wireless Sensor

OPERATOR S MANUAL MODEL AP15/AP15-1/AP15-2 PC-ALARM PANEL

SYSTEM ENHANCEMENT MODULE

Fratech Multipath-IP

FlameGard 5 MSIR HART

ST325. Thermostat. The ST325TX can be used with any of these receivers RXBC605 RXST625 RXRT505 RXVBC605 RXWBC MHz

DD15 Interface Module Product Guide

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

POP_ Smoke Detector

DTSX200 Communications(Modbus) Guide

Applications: 27. NETIChome mobile ios 28. NETIChome mobile Android. NETIChome basic elements

DeLaval activity meter system Instruction Book

The Leading Enterprise Internet of Things Solution. Wireless 0-20 ma Current Meters. General Description. Features of Monnit ALTA Sensors

POP_ Smoke Detector

Ei600ZW Z-Wave Module for 10 Year Smoke Sensor with Siren

installation & operation manual

80 CHANNELS WIRELESS RECEIVER WITH LCD DISPLAY M1.1.1-Hx.x-F1.1-ENG [AN] [SPV] MADE IN ITALY INSTALLATION AND USE MANUAL

Be prepared for Sigfox RF & Protocol Tests

The WAVE Plus Instant Notification System for Schools and Colleges

Wireless Call Point ( )

Wireless Internal Siren System Installation Guide

Operation Guide DQR-100U

Dec Wirsbo CoSy Radio. Installation and Operating Instructions

SRT321 User and Installation Instructions

MEDI-MINDER USER MANUAL

RS485 MODBUS Module 8AI

status AW1 WiFi Alarm System Printed in China PA : AW1-UM-EN-V1.0 User Manual 2016 Chuango. All Rights Reserved.

FW-SIREN2EXT -8/9F FW-SIREN2CP -8/9F

IC60 Sintony 60 Intrusion Control Panel

Heating is great when you control it. USER MANUAL. Wireless Programmable Room Thermostat. Model No.: LS Scan for App

SMOKE User Manual. NE v2.0

FieldServer Driver - Serial FS McQuay Microtech Open Protocol

WatchDog Wireless Crop Monitor Operation Manual

Panel XT210/610/ Description. Supervised Wireless Technology

Tinytag Plus LAN Data Logger with Temperature & Relative Humidity Probe (-25 to +85 C/0 to 100% RH) Standalone. Tinytag Connect

Sentrol. ShatterPoint Glassbreak Sensor. Installation Instructions DESCRIPTION. Models (3 Volt) (6 Volt) STEP 1 MOUNTING

SHEPHERD. Smart solutions to protect and manage what matters the most to you

EW 40 Wireless Fan Control

Model: RT310i. Smartphone Controlled Thermostat. Installation Manual

RF-KNX / TP-KNX MEDIA COUPLER CO KNX 002

The Genesis. Wireless PIR System. Se t t i n g n e w s t a n d a r d s f o r P I R d e t e c t i o n. BS8418 Compliant

Product Recall Notification TX-4200 Wireless Personal Panic Device

DD205RF/TX Detector Installation Sheet

Wireless Door Detector

X64 Wireless Training

SC-F3G User Manual 1.0

Instruction Manual Water Sensor

Overview. Wireless Overview QLD NSW VIC Fundamentals. Operation. Features.

FlameGard 5 UV/IR HART

The Leading Enterprise Internet of Things Solution. Wireless Duct Temperature Sensors. General Description. Features of Monnit ALTA Sensors

Construction of Wireless Fire Alarm System Based on ZigBee Technology

2 x CR123A Lithium batteries. White night-light LED. Blue alarm LED - also glows behind the lens. Ambient light sensor behind lens.

ABAX two-way wireless system

ESD Product Information

Z-Wave Network Inclusion/Exclusion/Reset

VTI MODEL itc5000 HEAT TRACING CONTROL SYSTEM OPERATIONS MANUAL

Figure 1. Proper Method of Holding the ToolStick. Figure 2. Improper Method of Holding the ToolStick

USER MANUAL FOR OPERATING SYSTEM

LA5579 Wireless Siren Operation Manual

The Leading Enterprise Internet of Things Solution. Wireless Thermocouple Sensors. Features of Monnit ALTA Sensors. General Description

Open Source Home Security System

>WIRELESS> ALARM SYSTEM CR200

PERMACONN PM1030 Includes DI300. Installation Manual

RAy SNMP. Application notes.

PROGRAMMABLE 7-DAY RF THERMOSTAT

Jon Longtin Department of Mechanical Engineering SUNY Stony Brook

Fratech Multipath-IP STU

PHILIO TECHNOLOGY CORPORATION

Description Supervised Wireless Technology PRODUCT SPECIFICATION SHEET

IM20-ZWAVE Magnetic Contact User Guide

600 Range Dialer Installation Manual. Version 1.0

CBI-064. User Manual. Caddx to KNX-BUS Interface

T4000 Security Communicator

10 Year Smoke Detector and Siren

System Guide.

Transcription:

Wireless Smart Metering LAN-WMBUS-M Wireless MBUS, door and window sensor. With optional glass break accessory. The LAN-WMBUS-M (I/A) (G)/(E)- is a activity sensor for detecting for example openings/closing of windows, doors etc. It can also be used for counting the number of openings in a certain timeframe. The sensor can be ordered in different configurations see the product matrix for more details. The devices have the following features. Wireless MBUS EN13757-3/4:2013 Standard. S, T and C- mode are supported. Superb antenna design and high output power for long range. Onboard Magnet sensor. Possibility to connect external wired magnet detector (E) Possibility to connect external wired glass break detector (G) Values can be send instantaneous (I) or accumulated (A). Sabotage detection if sensor is opened or removed from wall. AES 128 encryption. CBC Mode 5 OMS compliant. Very long battery lifetime, up to 14 years. Depending on how many openings, and MBUS-mode. Wide operating temperature range - 20 to +55 degree C. (other temperatures upon request) Plug & Play. Works right out the box, no complex installation needed. Low battery alarm. Available with optional high quality battery.

Product description The device is made up of a sensor and a magnet. Whenever the magnet is removed or returned to the sensor a message is sent (I-variant). The number of passages can also be accumulated and the total number of passages is transmitted in even intervals (A- Accumulated). Is also possible to further enhance the device by connect an external magnet detector through cabling (E-variant) or connect it to Lansen Glass Break device (G). Product Matrix Article Number External External Inputs interface LAN-WMBUS-M - - LAN-WMBUS-ME Magnet 2 LAN-WMBUS-MG GlassBreak 1 SE-301 05

Radio characteristics Frequency Chiprate S-Mode 868.3 MHz T-Mode 868.95 Mhz C-Mode 868.95 Mhz S-Mode 32.378 kcps T-Mode 100 kcps C-Mode 100 kcps Datarate S-Mode Chiprate /2 T-Mode Chiprate x 2/3 C-Mode Chiprate RF output power Antenna Transmission intervals accumulated values Retransmission 12dBm Integrated 15 minutes (other intervals are also available). 30 seconds during the first 4 minutes after powerup. 3 times for alarm (sabotage, Alarm) 2 times for other messages. Power and battery Power consumption Battery type Max 40 ma, SAFT LS 14500 3.6 V - AA Primary Li-SOCL2 (recommended) Max operating voltage 3.6V Minimum operating voltage 2.8V Lifetime Typical more than 10 years. W-MBUS Info Header type EN13757-3 APPLAYER LONG TRANSPORT HEADER (0X72) Encryption AES 128 CBC (mode 5) Sensor type Low battery warning Manufacture code 0x1D Door and Window device. Yes LAS (standard, other code if requested) SE-301 05

-A and -I variant Accumulated value. Example: 012345678912 DATA_FIELD_BCD_12_DIGIT; H.C.A Number of openings detected 12 BCD digits, instantiations accumulated value from the power up of the device Data is sent using H.C.A. That is unconverted data value. 0x0E 0x6E 0x01,0x23,0x45,0x67,0x89,0x12 Sabotage Detected Message. The sabotage message is always sent in two ways: Sabotage using Error Flag message. The message is only sent when the status of sabotage is changed. X->don t care that is not affected by the changed alarm condition. 0x02; (DIF field 2 byte integer) 0xFD; (VIF Extension table) 0x17; (VIFE Error flags binary manufacture specific 16 bits) (2 bytes) Sabotage detected.xxxx1 (Bit 0) Sabotage restored.xxxx1 (Bit 0) Sabotage using the manufacture specific status-byte in EN13757-3 APPLAYER LONG TRANSPORT HEADER (0X72). The bit is set to 1 as long as sabotage is detected. Sabotage detected 1 (Bit 5) Sabotage restored 0 (Bit 5) Low battery Low battery is sent using the power low bit in the status-byte in EN13757-3 APPLAYER LONG TRANSPORT HEADER (0X72) EN 13757-3:2013 Table 7 Coding of the status field Battery low 1 (Bit 2) Battery OK 0 (Bit 2) -I Only variant Alarm sent etc using the following encoding if any of the 3 alarm status have changed. The current status of the all 3 alarm ports are sent. X->don t care, that is not affected by the changed alarm condition. Alarm message is sent using Error Flag message as soon as the alarm status is changed. 0x02; (DIF field 2 byte integer) 0xFD; (VIF Extension table) 0x97; SE-301 05

. 0x1D; (VIFE Error flags binary 16 bits) (2 bytes) Alarm detected (door opened) XXXXXX1XX (Bit2) -> Any Reed are IN alarm condition (any door open) Alarm restored (door closed) XXXXXX0XX (Bit2) -> Reeds are NOT in alarm condition (all doors closed) Examples: X is don t care and is not affected by the change in alarm condition.. Operating conditions Storage temperature Operating temperature, Relative moisture - 55 to + 85 gr C -20 to + 55 gr C (other temperature upon request) Less than 95% non-condensing Casing Colour Dimensions Material White 25,5 x 105 x 22 mm ABS Conformity EMC EN 301489 Safety EN 60950 Radio EN 300 220 SE-301 05

Features for easier installation. Red LED indication when sabotage is detected Red LED indication when sabotage is restored When: When the device is opened or removed from the wall. (sabotage is detected) What: The LED flashes for 4 seconds at 4 Hz. Why: In order to verify that the sabotage detection is working. When: When the device is closed or placed against the wall again(sabotage is restored) What: The LED flashes for 2 seconds at 1 Hz. Why: In order to verify that the sabotage is restored and the device is closed and mounted correctly. Red LED indication of Alarm. When: When the magnet is removed from the device the red led is lit. This only apply to the first 4 minutes of operation (after battery is inserted) What: The LED is lit during alarm condition (door is opened) and turned off again after the magnet is placed nearby the device again ( door is closed) Why: In order to verify that the magnet and device is correctly mounted and is working as intended. Changelog Revision 1.1 Changed the packet type for sabotage and Alarm to better Martin 2015-10-12 comply with the Alarm message in the MBUS standard. The Hallberg new version is used in software version 2 of the LAN- WMBUS-M. Corrected the physical size of the device. Added information for the RED led during alarm condition. Changed device type from 0x1B to 0x1D SE-301 05