CONTROL PANELS. Tech Data Sheet D01688GB1 10/2012 Fire Detection. Control Panels of the FX 3NET (ALC) Fire Detection System

Similar documents
FX NET FIRE DETECTION SYSTEM Installation and commissioning manual

Esmi Sense FDP Fire detection panel with ALC2 loop controller

SOUNDER BASES AND SOUNDER BEACON BASES

FX FIRE DETECTION SYSTEM

Intellia Sounder Bases and Sounder Beacon Bases

FX NET. Advanced fire protection

AP200 SERIES INTELLIGENT ALARM DEVICES

ZXSe Range Data Sheet

AP200 SERIES INTELLIGENT ALARM DEVICES

Excel-EN Conventional Fire Control Panel

Fire control panel detect 3004 plus and accessories

Intelligent addressable fire alarm control panel

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

ZXSe Range. Fire Safety. Analogue addressable fire alarm control panel KEY FEATURES. Panel Features

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

FX FIRE ALARM SYSTEM (ALC) Planning Instructions

Fire control panels FC360

Labkotec Ice Detector

Different types of Fire Alarm System

FC722 Fire control panel

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

Wireless Fire & Security Solutions. Fire Product Showcase

FC700A Fire detection control unit

Multi-Gas-Controller MGC2

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM

FireNET Plus Wiring Instructions

MINERVA. Marine. Fire Detection. MX T2000 Panel Range. Features: MINERVA Marine Panel Range

Fire control panels FC726 FC726-XA

Advanced FireAlarm Panel 1-4Loop

System 800 Addressable Fire Detection & Alarm System

FC724 Fire control panel

NETWORK FIRE ALARM CONTROL PANEL. Features S7010 S :111

CONVENTIONAL FIRE CONTROL PANELS FS 5100 and FS 5200

FC722 Fire control panel

Intelligent Single Loop Fire Alarm Control Panel

Intelligent 2 & 4 Loop Fire Alarm Control Panels

Components Brochure DX CONNEXION

SUPREMATouch Modular Fire & Gas Detection System

DXc Control Panels. DXc1. DXc2. DXc4. Single Loop Control Panel, 230Vac, 2 sounder circuits. Dims 260 x 390 x 147mm (H x W x D)

INTELLIGENT FIRE ALARM CONTROL PANEL

Sinteso TM product catalog.

Control Panels. Control Panels for Commercial Applications. Control panels provide the central processing

Solution F2. Fire Alarm Control Panels one step ahead.

FC724 Fire control panel

FC330A-ECO Auto-addressing analogue 1-Loop fire detection panel

FC330A-ECO1 Auto-addressing analogue 1-Loop fire detection panel

Wireless Fire & Security Solutions. Fire Product Showcase

Synova TM product catalog.

CATALOG NUMBER. Features. Description

DUAL MONITORED INPUT/OUTPUT UNIT BN-305

NETWORK FIRE ALARM CONTROL PANEL. Features

For Complete Fire and Gas Solutions

APPLICATION DATA SHEET

Dräger Polytron 7000 Fixed gas detector

Process & TeMPerATUre UniversAl input DigiTAl MeTers

SI120 Guarto Easy I. Alarm system. Fire & Security Products

Technical Speci fications 220V AC 50Hz or 110V AC 60Hz Accessories operational voltage. 2x 12V / 7Ah sealed lead acid gel batteries

Dräger REGARD -1 Control System

PolyGard Single Point Controller SPC-X3-20XX for refrigerant gases and vapours

Fire Detection Systems Product Catalogue (Version )

ORENA BRAND CONVENTIONAL (ORENA Brand) CE

On the job around the clock 24/7: Fire detection systems

Addressable and Conventional Fire Protection

Fire and Gas Monitoring Panel ST7-HV

SUPREMATouch. Modular Fire & Gas Detection System

SCC Inc. Master Panel. Specifications. Document No. TS 2010 February 11, Product Description. Sample Specification

Fire Extinguishing Control Panel INSTRUCTION MANUAL. Revision 8/ Instruction Manual Page 1 Revision 8/01.17 of 63

Vigilant MX4428 Fire Alarm System

IQ8Control C Fire Alarm Panel

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 PRODUCT OVERVIEW

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description

FEC400 Series. Installation Manual

FC723 Fire control panel

Intelligent Security & Fire Ltd

ADR Analog Addressable Fire Alarm Control Panel. Technical Manual. Control Panels. 3000En. En pdf

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description

Basic Fire Alarm SystemTraining. Arman Alnasar

561-MB256 plus. Intruder alarm control panel. Performance features

MINERVA MX. 800 Series Ancillary Equipment

four Vigilon Compact Analogue Addressable Fire Detection & Alarm System 4/1

Intelligent Addressable Fire Alarm System

ECC-50/100C. Emergency Command Center

AE-CU Adaptive Escape Routing for Emergency Lighting. From static to adaptive escape routing

/8 DIN Level Indicator

IGD.CO.UK

Touchpoint Pro Flexible Gas Control System

Healthy. Atmosphere. for Pigs and Poultry. for a

Interactive Fire Control Panel IFS7002 four signal loops Instruction Manual

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3

Installation, Operating and Maintenance Manual

Extension Module. Fig.1

Touchpoint Plus. A whole new control experience

GPS or DCF 77. DTS Masterclock

System-X offers a variety of alarm interfaces suitable for different applications. The possibilities are:

Protec. Protec Algo-Tec TM 6500 Interactive Digital Addressable Fire Control System with Algo-Tec 6600 Bridging Network. Fire Detection - Addressable

FIRElux Emergency Lighting

Water Detection Controllers

Transcription:

Tech Data Sheet D01688GB1 10/2012 Fire Detection CONTROL PANELS Control Panels of the FX 3NET (ALC) Fire Detection System The FX 3NET intelligent fire detection and alarm system and panels from Schneider Electric have a modular construction and provide new features f efficient and reliable fire safety. The control panels are FX 3NET, FXL 3NET, FXM 3NET and FXS 3NET. The full range of Schneider Electric s intelligent and conventional detects can be connected to the system. A versatile built-in control logic enables easy control of both passive as well as active fire protective equipment and even a three-stage alert and evacuation alarm. The system is compatible with other fire detection equipment, such as the fireman s panel FMPX, zone led panel ZLPX, alarm delay panel DAPX, communication protocol repeater REPX and multipurpose MCOX, as well as alarm management system ESGRAF. The system also provides an OPC communication interface, which enables integration to the building management system. FX 3NET and FXL 3NET control panel Panel installation The FX panel is installed on a surface with the display at a height of approximately 170 cm. The wall has to be strong enough to suppt the weight of the panel and the batteries. Connections See overleaf f general overview of the connections of FX 3NET panels. FXM 3NET control panel Cable entries are from behind, from above and from below. Commissioning and Configuration The system can be started after the jumper settings are verified. F customer/site specific settings and entry of alarm texts, a PC and licensed software WinFX3Net is used. F further infmation, see the FX 3NET Installation and Commissioning Guide. FXS 3NET user interface

Tech Data Sheet D01688GB1 Fire Detection 2 Technical data of the FX 3NET panels Control panels FX 3NET FXL 3NET FXM 3NET FXS 3NET Product code 0070 3600 0070 3700 0070 3800 0070 3814 Dimensions (h*w*d) [mm] 578 x 425 x 130 328 x 425 x 130 328 x 417x79 Weight (fully equipped, excl. batteries) 11 kg 12 kg 6 kg 4.4 kg IP Rating IP30 Operating ambient temperature +5 +40 C Stage ambient temperature 0 +50 C Maximum ambient humidity 95% RH Back frame material sheet steel Cover material plastic Cover colour bluish grey Mains supply voltage 230 VAC ±10% / 50... 60Hz Mains supply power 160 VA 80 VA NA Operating voltage range 21... 30 Vdc Maximum current consumption in standby condition 1.0 A @ 24 Vdc 0.5 A @ 24 Vdc 0.5 A @ 24 Vdc Maximum current consumption in alarm condition 4.0 A @ 24 Vdc 2.2 A @ 24 Vdc 1.0 A @ 24 Vdc Applied standards EN54-2 EN54-4 EN54-2 Schneider Electric reserves the right to make modifications.

Tech Data Sheet D01688GB1 Fire Detection 3 Construction of the FX 3NET panels Base units Card slot options UI2 place options Battery space Control panels Note FX 3NET FXL 3NET FXM 3NET FXS 3NET FX-UI2 user interface 1 1 1 1 FX-MC2 master 1 1 1 1 FX-PSA power supply - - 1 - Note 1 FX-PSB power supply 1 1 - - Note 1 Card slots 5 9 2 1 Note 2 s 1 4 pcs together - FX-ALCA, 1 Intellia loop - FX-ALCB, 2 Intellia loops - FX-CLC, 16 conventional loops Control units 1 4 pcs together - FX-IOC - FX-OCA REPX-OB protocol repeater MCOX-OB logic control unit ZLPX-IC Display units - FX2-LB32 panel display units - FX-LB80 zone display units Batteries 2 pcs 12 V/17 Ah - 2 pcs 12 V/12 Ah Note 3 Note 4 - Note 5 Note 1 Note 1 Note 2 Note 3 Note 4 Note 5 FXS requires a power feed from an FXM, FX FXL panel. Available power from that panel may restrict the current consumption of the FXS panel. Card slots are f ALCA, ALCB, CLC, IOC, OCA, REPX-OB, MCOX-OB and ZLPX-IC option boards. s are optional. The maximum number of loop s is 1 in FXS, 2 in FXM and 4 in FX and FXL. Only 1 display unit per panel. The FX-LB80 is used in the UK. Batteries of the FXL 3NET panel are installed in a separate FX BAT cabinet.

Tech Data Sheet D01688GB1 Fire Detection 4 FX 3NET and FXL 3NET panel external connections Serial (RS485) communication with other FX panels (2 pcs) Serial (RS485/RS232) communication with INFO/FMPX/MCOX/DAPX/REPX/ZLPX Serial (RS232) communication with printer maintenance tool (PC) Ethernet connection, : Future option Master FX-MC2 USB connection, maintenance tool (PC) Fire Alarm Router Equipment (Alarm transmitter) Fault Warning Router Equipment (Alarm transmitter) Fire Alarm Output Power supply output 24 VDC, sht circuit protected, 500 ma Monited output (Bells, sounders, beacon), 500 ma Fault in Fire Alarm Router Equipment (Alarm transmitter) Fault in Fault Warning Router Equipment (Alarm transmitter) REPX-OB MCOX-OB ZLPX-IC External communication (not in ZLPX-IC) FX-ALCA, FX-ALCB pcs FX-ALCA: One addressable detection circuits, with 126 addresses FX-ALCB: Two addressable detection circuits, each 126 addresses FX-ALCA: One power supply outputs 24 VDC, sht circuit protected, 500 ma FX-ALCB: Two power supply outputs 24 VDC, sht circuit protected, 500 ma each FX-CLC pcs Input/output FX-IOC pcs F each FX-CLC: 16 Conventional detection circuits, function configurable Clean contact signal inputs (4 pcs), function configurable Clean contact relay outputs (2 pcs), max 30 VDC / 1.0 A, function configurable Monited relay outputs (4 pcs), max 500 ma each, function configurable Power supply outputs 24 VDC (2 pcs), sht circuit protected, 500 ma each Output FX-OCA pcs Clean contact relay outputs (16 pcs), max 30 VDC/ 1.0 A, function configurable Note! Power supply FX-PSB Power supply outputs 24 VDC (2 pcs), sht circuit protected, 4 A each 230 VAC / 50 Hz / 160 VA Battery 24 VDC (max 68 Ah) The maximum total load of the panel is 1.0 A in nmal condition and 4.0 A in alarm condition. The maximum number of ALCA, ALCB, CLC, IOC, OCA, REPX-OB, MCOX-OB and ZLPX-IC boards is 5 in FX and 9 in FXL.

Tech Data Sheet D01688GB1 Fire Detection 5 FXM 3NET panel external connections Serial (RS485) communication with other FX panels (2 pcs) Serial (RS485/RS232) communication with INFO/FMPX/MCOX/DAPX/REPX/ZLPX Serial (RS232) communication with printer maintenance tool (PC) Ethernet connection, : Future option Master FX-MC2 USB connection, maintenance tool (PC) Fire Alarm Router Equipment (Alarm transmitter) Fault Warning Router Equipment (Alarm transmitter) Fire Alarm Output Power supply output 24 VDC, sht circuit protected, 500 ma Monited output (Bells, sounders, beacon), 500 ma Fault in Fire Alarm Router Equipment (Alarm transmitter) Fault in Fault Warning Router Equipment (Alarm transmitter) REPX-OB MCOX-OB ZLPX-IC External communication (not in ZLPX-IC) FX-ALCA, FX-ALCB pcs FX-ALCA: One addressable detection circuits, with 126 addresses FX-ALCB: Two addressable detection circuits, each 126 addresses FX-ALCA: One power supply outputs 24 VDC, sht circuit protected, 500 ma FX-ALCB: Two power supply outputs 24 VDC, sht circuit protected, 500 ma each FX-CLC pcs Input/output FX-IOC pcs F each FX-CLC: 16 Conventional detection circuits, function configurable Clean contact signal inputs (4 pcs), function configurable Clean contact relay outputs (2 pcs), max 30 VDC / 1.0 A, function configurable Monited relay outputs (4 pcs), max 500 ma each, function configurable Power supply outputs 24 VDC (2 pcs), sht circuit protected, 500 ma each Output FX-OCA pcs Clean contact relay outputs (16 pcs), max 30 VDC/ 1.0 A, function configurable Note! Power supply FX-PSA Power supply outputs 24 VDC (2 pcs), sht circuit protected, 2 A each 230 VAC / 50 Hz / 80 VA Battery 24 VDC (max 34 Ah) The maximum total load of the panel is 0.5 A in nmal condition and 2.2 A in alarm condition. The maximum number of ALCA, ALCB, CLC, IOC, OCA, REPX-OB, MCOX-OB and ZLPX-IC boards is 2.

Tech Data Sheet D01688GB1 Fire Detection 6 FXS 3NET panel external connections Serial (RS485) communication with other FX panels (2 pcs) Serial (RS485/RS232) communication with INFO/FMPX/MCOX/DAPX/REPX/ZLPX Serial (RS232) communication with printer maintenance tool (PC) Ethernet connection, : Future option Master FX-MC2 USB connection, maintenance tool (PC) Fire Alarm Router Equipment (Alarm transmitter) Fault Warning Router Equipment (Alarm transmitter) Fire Alarm Output Power supply output 24 VDC, sht circuit protected, 500 ma Monited output (Bells, sounders, beacon), 500 ma Power supply input 24 VDC (2 pcs) from an FX, FXL FXM panel, separately monited f low voltage Fault in Fire Alarm Router Equipment (Alarm transmitter) Fault in Fault Warning Router Equipment (Alarm transmitter) REPX-OB MCOX-OB ZLPX-IC External communication (not in ZLPX-IC) FX-ALCA, FX-ALCB pcs FX-ALCA: One addressable detection circuits, with 126 addresses FX-ALCB: Two addressable detection circuits, each 126 addresses FX-ALCA: One power supply outputs 24 VDC, sht circuit protected, 500 ma FX-ALCB: Two power supply outputs 24 VDC, sht circuit protected, 500 ma each FX-CLC pcs Input/output FX-IOC pcs F each FX-CLC: 16 Conventional detection circuits, function configurable Clean contact signal inputs (4 pcs), function configurable Clean contact relay outputs (2 pcs), max 30 VDC / 1.0 A, function configurable Monited relay outputs (4 pcs), max 500 ma each, function configurable Power supply outputs 24 VDC (2 pcs), sht circuit protected, 500 ma each Note! Output FX-OCA pcs Clean contact relay outputs (16 pcs), max 30 VDC/ 1.0 A, function configurable The FXS 3NET panel requires a power feed from an FX 3NET, FXL 3NET FXM 3NET panel. The maximum number of ALCA, ALCB, CLC, IOC, OCA, REPX-OB, MCOX-OB and ZPLX-IC boards is 1.

Tech Data Sheet D01688GB1 Fire Detection 7 0832 Pelco Finland Oy P.O. Box 415, 02601 Espoo Finland 09 F FX 0832-CPD-1082 Issue 4 F FXL 0832-CPD-1083 Issue 3 F FXM 0832-CPD-1084 Issue 3 EN 54-2:1997/AC:1999/A1:2006 EN 54-4:1997/AC:1999/A1:2002/A2:2006 Options: 7.8; 7.9.1; 7.10.3; 7.11; 7.12.2; 7.13; 8.3; 8.4; 8.9; 9.5; 10 Control and indicating equipment f fire detection and fire alarm systems f buildings FX, FXL, FXM Other technical data: 66571764: installation and commissioning 66571774: operation manual 66571758 (SLC), 66571761 (ALC): system planning (held by the manufacturer )