LOCAL EXTRACTION Pure advantages. The ideal extractor for light industry and laboratory environments.

Similar documents
ALUMINUM REPAIR CERTIFICATION EQUIPMENT. Eliminate hazardous aluminum dust with a Eurovac system. BODY REPAIR CERTIFICATION EII Wet Mix Dust Collector

PERMA arm. Extraction arm. The lowest pressure loss

A hood is installed at the tip of every suction element to make sure of an efficient extraction. You can choose between different versions.

F17W44_MFB_F_EN INSTALLATION INSTRUCTIONS

Extraction systems for the electronic industry. Soldering workstations Soldering smoke extraction systems

Optimal work climate with open doors. Industrial air curtains Model IndAC

The Silent Range Pure Elegance & Tranquillity. The widest range of ultra quiet silent fans

Equipment guide for local exhaust ventilation (LEV)

HD 5/11 C Plus. Automatic pressure cut-off. Pump technology

Clean Air Laminar Flow Ceiling CG 3 A CLEAN AIR WORLD. Draft-free, comfortable room climate. Minimal, undisruptive noise level

DOMEKT ReCU 400VE(W)CF-EC-C4 Series Air Handling Units Installation and Maintenance Service Manual

Fume extraction system FEC.

Operating Instructions

User s Manual MATRIX A MATRIX S MATRIX A. Filtro de aspiración Movil Matrix Tel.

Technical Catalog laboratory furniture system

The green and friendly entrance. Comfort air curtains Model CA 2

Cold water HD 9/18-4 ST

Factory & Hospital hygiene, Chap 21(7 th edition) Principles of GMP, Chap 23 (8 th edition )

ATEX instruction for APP / PAH PAHT G 2-90 / PAH Tech

Fans for Life! CA-TD0708. The World s Leading Producer of Air Movement Products

Halton Rex 600 Basic R6B - Active chilled beam

Cold water compact class HD 5/11 C. Standard accessories: Trigger gun Extended highpressure. Technical data

Technical Catalog laboratory furniture system

Gas heaters and convectors ROBUR

D. NEMA Compliance: Provide electric motors and components which comply with NEMA standards.

4 Storage cabinets SCALA

hp Dust Collector With Vacuum Attachment

Vacuum Hose Reel 881 Ex

CREATING A CLEANER ENVIRONMENT EAZIFLO FUME CAPTURE SYSTEM

BRIZA_038. EC MOTOR Briza Hybrid: High performance technology

Contents. Technical Description of the Air Handling Unit General, Specification Function, Functional Sections

Units for suspended ceilings

1. Oxygen Master 2. Oxygen Sensor 3. Oxygen Refresh Stand-Alone 4. Touch button controls 4. Oxygen Refresh Built-In 5.

Safety vacuum cleaner with automatic filter cleaning system, 42 l, class L

analytical laboratory clear amber bottles clear bottles

A. Codes and Standards that are Standard at the University:

CERAMIC PUMPS FGP. Horizontal Liquid Ring Pumps Solid and gas-tight silicate ceramic for gases and vapours.

HasconWing. Fixed or variable airfoil profile axial impellers

Axial flow fan AXICO ANTI-STALL

XPert Balance and Bulk Powder Enclosures

Air distribution systems. Opticlean OC-Q...

Domestic & Commercial Fans

Secuflow laboratory fume cupboards

Technical Catalog laboratory furniture system

Sentry Air Systems, Inc.

Güntner Info GVX. with microox technology kw. Always a step ahead: microox condenser system with maximum installation flexibility

HD 7/11-4 Cage Classic

CUMULUS CUMULUS. Key figures. Construction. Function Integrated chilled beams

Secuflow laboratory fume cupboards

Safety vacuum cleaner with automatic filter cleaning system, 30 l, class L

ovens line elettrodrago for bread and pastry

Technical Catalogue laboratory furniture system

Phenomena up close. Demonstration fume cupboards. Special features

FILTERCUBE 2N We set air in motion

CERAMIC PUMPS FGP. Horizontal Liquid Ring Pumps Solid and gas-tight silicate ceramic for gases and vapours.

HD 6/13 C. Compact, high performance pressure washer with unique stand-up or lay-flat operating positon and large carry handle. 3 Accessory storage

RFE PLUS RFCE PLUS. Electric Radiator with Digital Control & Programmer. 430mm High Conservatory Electric Radiator with Digital control & Programmer

Aluminium Curtain Tracks

Puri-Drall PDK. Puri-Clean PCK. Puri-Inlet PEK. HEPA filter air outlet with pull-down outlet element

The power of ventilation

BTBa. FLUSHLINE Ventilated chilled beam for cooling, heating and ventilation. BTBa

OPERATING INSTRUCTIONS. HELIOS SAFE INDUSTRY ATEX 1500 Watt COD. EHSAFE Watt COD. EHSAFE20

our contribution for Sealless Magnetic Coupled, Heavy Duty Side-Channel Pumps environmental protection Type SCM PN40

Models SCA and SCB. ceiling-mount cartridge dust collectors. Model SCA. Model SCB

TRS 292, ST ST-97

Purge Ventilation Unit. Product Manual. ventilation systems TP625

INSTALLATION FB T: +44 (0) F: +44 (0) E: W:

Twin radial blower DRG 1200 with oval resistor, 12 and 24 Volt versions

Technical Ventilation

B. HI Compliance: Design, manufacture, and install pumps in accordance with HI "Hydraulic Institute Standards."

Twin radial blower DRG 1200

THIN PROFILE CENTRIFUGAL FAN COIL UNITS SLIM

Cold water compact class HD 5/15 C

L a b o r a t o r y E q u i p m e n t C a t a l o g

Technical Catalogue laboratory furniture system

WOLF VENTILATION SYSTEM PRICE LIST

Axial fans The right fan for every house

Air distribution systems. Opticlean OC-Q... DS 4136 E /1

Fume Extraction Workstation

DOMEKT ReGO 400VE(W)-B Series Air Handling Units Installation and Maintenance Service Manual

WHY SULLAIR? For more information on the IHI-Sullair joint venture, please visit 2,000th IHI-Sullair centrifugal

FULL RANGE of products for the protection of boilers and water heating loops SLUDGE FILTERS FDM-1P / FDM-2 / FDM-3

High pressure cleaning heads cleanliness all around

Pipe Support Systems

Safety vacuum drying oven for flammable solvents

Cold water compact class HD 5/17 C

Operating Instructions

WHHR Midi & Midi Lite

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

Contents. How to choose Recovery Ventilation type?...3. How do HRV, ERV and TRV Systems work?...4. Types of installations...5. VUT 200 H mini...

G Installation manual Solitude - dmev unit

CONDOR. Supply air ceiling QUICK FACTS

HDS 5/11 UX. Entry-level, highly portable hot water pressure cleaner with integrated hose reel. Integrated hose reel. Innovative upright design

Air handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation

HD 5/12 C Plus. Compact, high performance pressure washer with unique stand-up or lay-flat operating positon and large carry handle.

EHH SERIES DRAW THROUGH FAN COILS CFM

Filters & Centrifugal Separators

FAN ENGINEERING. Sealing of Fan Housings

ECV SP GUE ALO CAT ICAL TECHN

Pulse Jet Baghouse ASTEC PULSE JET BAGHOUSE. for Asphalt Facilities

Transcription:

The ideal extractor for light industry and laboratory environments. With its optimal design, the mm FUMEX ME has a very low pressure drop, which provides many valuable benefits. - Low pressure drop saves energy. - Air flow noise is reduced. - Lower pressure drop is achieved without selecting a larger diameter extractor. - Lower pressure drop allows the ME to be combined with additional extraction systems. To further facilitate maneuvering of the extractor, the models 1650 and 1900 are equipped with a pulling gas spring as standard and the models 2100 and 2650 with two pulling gas springs. An easy-to-grip handle facilitates the maneuverability of the extractor. Unique design and stable mounting brackets make the Fumex ME your best choise. Support for designing an effective system can be found on page 5, and at www.fumex.com where you will find our design tool and CAD drawings. The Fumex range also includes fans, accessories, automatic control and filters suitable for local extraction. LOCAL EXTRACTION Pure advantages

Always choose a low pressure drop Lowest possible pressure drop is a quality aspect that always should be considered. With its uniquely designed joint construction, Fumex ME combines maximum flexibility with low pressure drop. The air passes through the joints without creating unnecessary turbulence, thus producing an energy-saving low pressure drop and a quieter working environment. Recommended air flow The recommended air flow for a Ø100 arm is 200-300 m³/h, See table and diagram. Activity Air flow Laboratories 200-300 m 3 /h 55-80 l/s Light industry 300 m 3 /h 80 l/s Static pressure drop (Pa) 400 300 200 100 50 100 150 200 250 300 350 400 450 500 Air flow (m 3 /h) Static pressure drop is measured in accordance with ISO standard 5167-1. Optimal capture For optimum benefit from the local extractor, it is important to use the flexibility of the extractor to get as close to the contaminant as possible. A good rule of thumb would be a distance of 2 3 times the diameter of the extractor tube. At the recommended air flow, the extractor will provide high efficiency even if disturbances are generated in the surroundings. 0-300 mm Unique benefits The Fumex ME s joints have a patented friction design that, combined with the large joint diameter and single grip handle, provide a secure, position-stable arm with smooth adjustments. All without the need to apply excessive force or use tools on the adjusting knob. Joints with reinforced ends and ball bearings moderate the friction and allow the arm to be moved up and down while maintaining stability and function. Handle for easy adjustment A steady and easily accessible handle, that provides easy adjustment, is fitted as a standard on all models of Fumex ME Ø100 mm.

One arm. All options. Fumex ME has a complete range of accessories to suit every situation, enabling you to create the optimal extractor for the evacuation of hazardous airborne gases and particulates. PP version Used primarily for evacuating very corrosive contaminants in high concentrations, e.g. in certain laboratories and in the pharmaceutical and chemical industries. Standard version Suitable for evacuating most types of airborne contaminants, e.g. in laboratories, schools, hospitals, the pharmaceutical industry, nail salons and light industrial applications. ATEX version Suitable for evacuating airborne contaminants where there is a requirement for an ATEXclassified environment, e.g. in laboratories, the chemical and petrochemical industries, gas distribution, and the paint and pharmaceutical industries.

MET for ceiling and wall mounting, 3 joints Standard Size (mm) Gas spring Weight MET 1150-100 450 350 100 0 4,9 MET 1350-100 550 450 100 0 5,4 MET 1650-100 750 550 100 1 5,9 MET 1900-100 1000 550 100 1 6,4 MET 2100-100 1000 750 100 2 6,9 MET 260 135 125 B MET 2650-100 1300 1000 100 2 7,4 A PP Size(mm) Gas spring Weight MET 1150-100PP 450 350 100 0 4,9 MET 1350-100PP 550 450 100 0 5,4 MET 1650-100PP 750 550 100 1 5,9 MET 1900-100PP 1000 550 100 1 6,4 MET 2100-100PP 1000 750 100 2 6,9 MET 2650-100PP 1300 1000 100 2 7,4 MET for ceiling or wall mounting, excluding bracket MTI or MVK-125. ATEX Size (mm) Gas spring Weight MET 1150-100EX 450 350 100 0 4,9 MET 1350-100EX 550 450 100 0 5,4 MET 1650-100EX 750 550 100 1 5,9 MET 1900-100EX 1000 550 100 1 6,4 MET 2100-100EX 1000 750 100 2 6,9 MET 2650-100EX 1300 1000 100 2 7,4 Pressure drop 600 500 58dB(A) Static pressure drop (Pa) 400 300 200 46 52 100 41 50 100 150 200 250 300 350 400 450 500 Air flow (m 3 /h) Static pressure drop is measured in accordance with ISO standard 5167-1. Noise level is measured in accordance with ISO standard 3743. Indicated sound level refers to sound pressure level.

MEB for table mounting, 3 joints Standard Size (mm) Gas spring Weight MEB 1150-100 450 350 100 0 4,9 MEB B MEB 1350-100 550 450 100 0 5,4 A MEB 1650-100 750 550 100 1 5,9 MEB 1900-100 1000 550 100 1 6,4 PP Size (mm) Gas spring Weight MEB 1150-100PP 450 350 100 0 4,9 MEB 1350-100PP 550 450 100 0 5,4 MEB 1650-100PP 750 550 100 1 5,9 260 MEB 1900-100PP 1000 550 100 1 6,4 ATEX Size (mm) Gas spring Weight MEB 1150-100EX 450 350 100 0 4,9 MEB 1350-100EX 550 450 100 0 5,4 135 125 134 Ø 6 (4X) 119 MEB 1650-100EX 750 550 100 1 5,9 MEB 1900-100EX 1000 550 100 1 6,4 Reach at recommended installation height The following installation heights and sideways displacement relative to the work area are recommended for optimal extraction: Recommended installation height Designation H (mm) MET 1150-100 1700-2000 MET 1350-100 1900-2200 MET 1650-100 2000-2300 MET 1900-100 2200-2500 MET 2100-100 2300-2500 MET 2650-100 2300-2500 MET 2650 MET 2100 MET 1900 MET 1650 MET 1350 MET 1150 MET 2650 MET 2100 MET 1900 MET 1650 MET 1350 MET 1150 500 1000 1500 S 500 1000 1500 2000 900 2000 H 500 1000 1500 2000 2500 2500 Recommended side displacement radius, relative to work area 900 Designation S (mm) MET 1150-100 300-600 MET 1350-100 400-700 MET 1650-100 500-800 MET 1900-100 700-800 MET 2100-100 700-900 MET 2650-100 900-1300 MET2650 MET2100 MET1900 MET1650 MET1350 MET1150 Working radius Maximum radius

Hoods 90 260 Ø 250 METAL HOOD The metal hood is used when working in corrosive environments and for capturing hot gasses and dust splatter. Metal hoods can be fitted with work lighting. MEM 251-100 PP, EX 510 Standard/PP: EX Powder-coated aluminium Powder-coated aluminium 110 295 Ø 350 DOME HOOD The clear dome hood is suitable for lighter gasses with a wider dispersal of contaminants without blocking the user s vision. MEK 351-100 PP,EX 610 Standard: PP EX PMMA Polypropylene, transparent PEEL black 180 360 Ø 500 DOME HOOD The clear dome hood is suitable for lighter gasses with a wider dispersal of contaminants without blocking the user s vision. MEK 500-100 PP,EX 735 Standard: PP EX PMMA Polypropylene, opaque PEEL black 470 590 SQUARE HOOD The square hood is suitable for placing above gases with a high lift, or adjacent to the work surface for contaminants with no lift or low lift all this without interfering with the work. MESH 500-100 1125 Standard: PETG 560 250 120 375 187,5 200 FLAT SCREEN HOOD The flat screen hood is designed to maximise the working area without obscuring the object from the user. The flat screen hood gives the best suction effect for table and bench tasks. Temp. range: -15 C to +80 C MEPH 375-100 PP,ES, EX 625 Standard: PP EX PETG Polypropylene PEEL black PROTECTIVE GRILL Protective grill to be monted in joints. Prevents objects being sucked into the system. MESG-100 EX 12 Standard, EX: EN 1.4436

Brackets All Fumex laboratory extractors have as standard a full swivel that allows 360 of rotation without the need to add special sleeve couplings. Both ceiling and wall brackets have a special squareshaped profile in anodised aluminium to provide a stylish and stable installation. This aluminum profile also allows both the wall and ceiling brackets to be custom tailored at the job site. MTI MTI CT The MTI ceiling bracket The ceiling bracket functions as a simple and stable duct for outgoing air, avoiding the need for expensive ducting and additional holes through false ceilings. On request, the MTI can be supplied in lengths exceeding 2 m. Dimensions Weight (mm) Standard L (kg) MTI 500-125 500 4,90 MTI 750-125 750 5,80 MTI 1000-125 1000 6,75 MTI 1250-125 1250 7,65 MTI 1500-125 1500 8,60 MTI 1750-125 1750 9,50 MTI 2000-125 2000 10,40 Static pressure drop (Pa) 40 35 30 25 20 15 10 5 Air flow (L/s) 20 40 60 80 100 120 140 MTI-125 100 200 300 400 500 Air flow (m 3 /h) Ø10(x4) 250 220 L Ø125 150 134 The MTF ceiling bracket Ceiling bracket, for fitting through beams. The attachment plate is adjustable for the entire length of the aluminium profile. If required, the aluminium profile can be cut during fitting. Ø10 (x4) Ø125 Dimensions Weight (mm) Standard L (kg) MTF-125 1000 5,50 As well as the standard design, the MTI/MTF is available in an ATEX (EX) version. 5 The ceiling brackets can be supplied with an epoxy-coated exterior in all lengths up to 3 m (L). For aggressive environments, we recommend epoxy coating on the interior and exterior up to 1.25 m (IL). 250 220 1000 60 134 The MTI CT escutcheon plate Escutcheon plate, used with the MTI ceiling brackets for stabilization and to cover ducting in false ceilings. Weight Standard (kg) MTI CT-125 0,125 205 245 As well as the standard design, the escutcheon plate is available in an ATEX (EX) version. Ø 10 (4X) 3 MVK wall bracket Wall brackets can be special ordered in custom horizontal and vertical lengths. Weight Standard (kg) MVK-125 2,5 120 96 200 175 Ø 10 (4X) 232 Ø125 150 60 As well as the standard design, the bracket is available in an ATEX (EX) version.

20180620 description Friction joints Ball bearing-equipped adjustable friction joints in polypropylene (PP), with guide ring in low friction-treated rubber. Support springs and other component parts in zinc-plated steel or stainless steel. Tubes Made from thin-walled anodised aluminium or from polypropylene. Air-tight damper supplied as standard. ME Standard The standard ME version has polypropylene joints and anodised aluminium tubes. The standard ME version is suitable for evacuating most types of airborne contaminants, e.g. in laboratories, schools, hospitals, the pharmaceutical industry, hairdressing salons and light industrial applications. Delivery Ceiling- Supplied assembled, excluding hood. The MTI or MET MTF ceiling brackets should be ordered separately. Wall- MET Table- MEB Supplied assembled, excluding hood or suction nozzle. MVK-125 wall bracket should be ordered separately. Supplied assembled, with attachment plate for table fitting, excluding hood. The MBF flexible table bracket should be ordered separately. ME PP Polypropylene joints and tube version. All metallic parts that are in contact with the air flow are made of stainless steel. The PP version of the ME is used primarily for evacuating very corrosive contaminants in high concentrations, e.g. in certain laboratories and in the pharmaceutical and chemical industries. When using a PP extractor fitted to a ceiling, we recommend that you order the MTI ceiling bracket with an internal epoxy coating. ME ATEX Conductive polypropylene joints and tubes. All metallic parts that are in contact with the air flow are made of stainless steel. Static electricity is diverted to a separate earth connection. All steel supporting parts are lined in a conductive powder coating. The product meets the requirements of category 2 of the ATEX directive (94/9/EC) for gases and dust. The ATEX version of the ME is suitable for evacuating airborne contaminants where there is a requirement for ATEX-classified products, e.g. laboratories, the chemical and petrochemical industries, gas distribution, and the paint and pharmaceutical industries. Verkstadsvägen 2, 931 61 Skelleftea, Sweden Tel : 0910-361 80, Fax: 0910-130 22 www.fumex.com info@fumex.se