Simply safe. Transponder-coded safety switch CET with guard locking

Similar documents
Simply safe. Transponder-coded safety switch CET with guard locking

Connection of CET4-AR to safety relay PNOZ s5

Connection of CET4-AR to safety relay PNOZ X3.10P

Connection of CES-AP to safety relay PNOZ s4.1 Content

SPECIALISTS IN SAFETY ENGINEERING FOR THE PACKAGING INDUSTRY.

Connection of CET4-AP to Siemens ET 200S

More than safety. Operating Instructions Safety Switch CET.-AS-...-CB-... (Multicode)

Multifunctional Gate Box MGB. More than safety.

ATEX Safety Switches. More than safety.

Examples for Use of the MGB Inputs and Outputs

One giant leap for safety: AZM400.

Original operating instructions Safety switch with guard locking AC901S AC902S

Safety in system: Protection for man and machine Innovations 2016/2017

Non-contact, coded safety switches PSEN

SAFEMASTER PRO. The configurable safety system versatile and extendable. Our experience. Your safety.

Automation at first hand. years

Basics of Safety Applications

ISIS SAFETY SYSTEM Installation guide

Danfoss gas detection unit Type GD Heavy Duty

Functional Safety of Machinery Presented by Greg Richards Manufacturing in America 02/22-23/2017

Bernstein product overview

Preventa safety modules

Basics of Safety Applications

AM1 alarm module. RESOL AM1 alarm module * * Mounting Connection Function. Manual

Machine Guarding and Safety

Outdoor Condensing Unit - ZX Range. High Efficiency In Compact Design

SAFEMASTER STS. The key to more safety. Our experience. Your safety.

Protective system controls, automatic burner control units, burner control units. Industrial & Commercial Thermal. 6 Edition 06.

Outdoor Refrigeration Unit - ZX Range High Efficiency In Compact Design

Sensing light curtain as per DIN 18650/EN 16005

Security Considerations for Secure Workplaces

Product overview. Alarm indicator, operator and display panels

LIGHT CURTAINS. Measuring and switching light curtains for a wide variety of applications.

1.7 A-ISOMETER IRDH575. RoHS. Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

Rotary Screw Compressors. ASK Series With the world-renowned SIGMA PROFILE Flow rate 0.79 to 4.65 m³/min, Pressure 5.5 to 15 bar.

Datasheet - MZM 100 ST-SD2PREM-A

UniVario Industrial Fire Detectors Versatile in Application

Hands On: Introduction to Safety Workshop Presented by Robert Jones Manufacturing in America March 14-15, 2018

ThermoControl 0 C - 10 C - 20 C - 30 C

TOOLS 8000 SOFTWARE FOR THE ENTIRE LIFE CYCLE OF YOUR FIRE DETECTION SYSTEMS

Operating instructions Safety-monitoring module SRB 302X3. 1 About this document

Datasheet - MZM 100 B ST2-SD2PREM-A

Danfoss gas detection Controller unit

Clino Guard. Intelligent Life Care. Solutions for safe and efficient care

Sensing light curtain as per DIN 18650/EN 16005

Operating instructions Safety-monitoring module SRB 302X3. 1. About this document. Content

Controllers, Indicators & Set Point Programmers

Machinery Safety. Safety Relays Safety Switches

Steam and Condensate Technology. Solutions which are brilliant in their simplicity. combined with a first-class design & consultancy service.

Sprecher + Schuh Motor Control and Protection Products

Underfloor Heating and Cooling Controls RELIABLE, ENERGY EFFICIENT CONTROLS FEATURING UNIQUE

Why Should You Invest In An Access Management System?

GEZE SAFETY TECHNOLOGY. GEZE SecuLogic EMERGENCY EXIT SYSTEMS SAFETY ON ESCAPE AND RESCUE ROUTES BEWEGUNG MIT SYSTEM

Transponder reader TECHNICAL SHEET (White) (Magnesium)

Clino System 99. Intelligent Life Care Integrated Communication Systems for Care Provision

Selection Guide. Logic: From basic to programmable network controllers» Safety Components. Output: Safety relays, servo systems, and inverters

Danfoss gas detection units

Datasheet - MZM 100 ST2-1P2PWREM-A

Burner control unit BCU 370

designed for rail 5000 Series

For Complete Fire and Gas Solutions

FACTORY AUTOMATION. INSTRUCTION MANUAL Interrogation data set for welding tongs NBN3-FXA-3E2-2V1

Electronic steam boiler controls

Refrigerant valves. Valves for precise control and optimum energy efficiency in refrigeration systems. Answers for infrastructure.

PROTECT SRB 200EXi-1A

Safety Sensor Eden AS-i Machine safety - Jokab Safety products

Operating Instructions for Limit switch Model: NBK-R NBK-RM NBK-RT NBK-RA

Datasheet - AZM ZRK 24 VAC/DC Solenoid interlock / AZM 170

AE-CU Adaptive Escape Routing for Emergency Lighting. From static to adaptive escape routing

The next generation thermometer from the global leader

GMA Panels with double busbar

CONDAIR EL. Electrode boiler steam humidifier Easy maintenance with replaceable cylinders. Humidification and Evaporative Cooling

Clino Guard. Safety without Compromise

PROFIBUS-PA Display RID 261 PROFIBUS-PA

SAFETY INTERFACES SAFETY INTERFACES AND RELAYS

Mastering challenges. Opening communication channels. Redefining flexibility. R100 Series Small Photoelectric Sensors

SCC Inc. TS Series. Technical Instructions. Document No. TS 5000 February 12, TS CE Combustion Enclosures with LMV3.

The Right Temperature, Always THS Series Modular Thermostats

WAGO-I/O-SYSTEM 750 Explosion Protection via Intrinsic Safety

TD Series Temperature Transmitter with Local Display. One-piece sanitary construction 2-wire electronics High accuracy

ETC. Echo Control Series ORDERING INFORMATION. Unison Echo Lockout Station. Related EchoConnect Power Supplies GENERAL INFORMATION

A stack full of solutions Wood-processing

NEW. Product news 2017/2018 Simple. Inspiring. Efficient. Digital time switches top3. Smart Home System LUXORliving. Motion detector theluxa R

Weishaupt dual fuel burners Sizes 30 to 70 Version 1LN (NO X -reduction on gas operation) 1/2003 CA

TA-Compact-P. Giving you MORE by giving you LESS

Product Training Module: Limitless Wireless Operator Interface WOI Series. Copyright 2012 Honeywell International Inc. All rights reserved.

Branching and Connection Box AAB. Operating manual AAB EN11. GTE Industrieelektronik GmbH

Datasheet - AZM ZRK 24 VAC/DC

Process air cooler series DV

Recalibrate the way you look at gas detection

PROCESS AUTOMATION PROTECTING YOUR PROCESS THE DEFINITION FOR INTRINSIC SAFETY K-SYSTEM K-SYSTEM THE MOST TRUSTED NAME.

RFID Non-contact switches are designed to monitor hinged, sliding or removable guard doors. RFID technology provides increased tamper resistance.

All tested. Easy Series Intrusion Control Panel Making security easy featuring wlsn* * wireless Local SecurityNetwork

Effective, efficient response for emergency situations Risk Management

A magazine full of solutions. Machine tools

the next generation thermometer from the global leader

SensaGuard TM Integrated Latch Installation Instructions

Single Source for Machine & Process Safeguarding Solutions

Safety, Productivity and Risk Assessment Services For Industry

LZR -FLATSCAN SW SAFETY SENSOR FOR FULL- AND LOW-ENERGY AUTOMATIC SWING DOORS. Visit website for available languages of this document.

Transcription:

Simply safe. Transponder-coded safety switch CET with guard locking

Safety switch CET The CET combines a mechanical guard locking with an electronic coded actuator. Versatile The CET is used in securing safety doors of machines and installations for the protection of persons and processes. Thanks to the guard locking function with guard lock monitoring, the CET is also ideal in case of overtravelling machine movements. Its very robust metal housing allows the CET to be used in the harshest environmental conditions. It achieves a locking force of 6,500 N in the locked state, which is particularly advantageous for large and heavy doors. In the version with double insertion slide, the CET is perfect for use with swing doors and rotary tables. Simple function The CET is mounted on the fixed part of the safety guard, and the actuator with its spring-loaded plunger and transponder on the moving part. When the safety guard is closed, the plunger of the actuator is guided into a recess via the insertion slide of the CET. The recess also contains the read head. It detects the safety guard in closed position and in locked position. The internal evaluation electronics or an external evaluation unit releases the safety circuit when the safety guard is locked. A start button and a feedback loop can be optionally integrated. PL e EN ISO 13849 Category 3 EN ISO 13849 Category 4 EN 14119 Different coding levels Unicode coding Each CET actuator has a unique code and significantly surpasses the requirement in EN ISO 14119 for a type 4 switch with high coding level. The uniquely coded actuator is specifically assigned to the safety switch via a teach-in operation. As such bypassing the safety guard using another actuator of the same type is effectively prevented. In this way the requirement in the standard for effective protection against tampering is met. If a fault occurs, a new actuator can be taught-in at any time. On teaching-in the new actuator the previous actuator automatically ceases to be valid. Multicode coding For applications in which an actuator with a high coding level is not necessary, it is of course possible to use a multicode safety switch. The actuator is not specifically assigned to the safety switch here. It is only checked whether or not the actuator is a valid actuator. Easy compliance with standards Thanks to the combination of mechanical guard locking and transponder technology, the safety switch grants a maximum level of safety. Performance Level e (PL e) and Category 3 or 4 (depending on the install - ation position) according to EN ISO 13849 are achieved with one CET. The CET also obviously meets the requirement from EN 14 119 for monitored guard locking. Installation position Achievable category and PL according to EN ISO 13849-1 Installation position Achievable category and PL according to EN ISO 13849-1 Head upward Head downward or horizontal 3 / PL e 4 / PL e

Types of guard locking Two different types of guard locking are used with the CET. Mechanical guard locking: guard locking by spring force. Release by applying voltage to the guard locking solenoid (closed-circuit current principle). Electrical guard locking: guard locking by solenoid force. Activation of guard locking by applying voltage to the guard locking solenoid (open-circuit current principle). Door monitoring output (available for variants with integrated evaluation electronics) This allows the position of the safety door (open/closed) to be recognized. Simple bus connection with AS-Interface In the version CET-AS, the safety switch can be either directly connected in the control cabinet or operated on the AS-i bus via a coupling module. The wiring is thus no longer required. All information of the CET is provided to the control system via the AS-i bus. Comprehensive, well-thought-out accessories Whether it be mounting plates for simple attachment, various unlocking and release aids, assembled cabling or various bolt systems, the comprehensive range of accessories offers maximum flexibility for integration and assembly. Lockout mechanism prevents activation of the guard locking. To do this, the lockout mechanism is attached to the CET actuator. In locking position, the lockout mechanism can be secured with up to three locks. Emergency unlocking allows to unlock the CET manually. Mechanical key release allows authorized personnel to operate the mechanical release in certain situations. Mounting plates and bolt system for the simple mounting of the CET on profiles.

CET system families Matched to specific customer requirements, EUCHNER offers four connection and wiring concepts: CET-AX Consists of a read head and an actuator. Evaluation takes place via separate CES-AZ evaluation units. CES-AZ 1...2 CES-AZ 1...4 Type of evaluation: - Evaluation unit CES-AZ Maximum number of read heads 1...4 CET-AP Consisting of a safety switch with internal evaluation electronics and an actuator. The CET-AP is suitable only for separate operation. Safe PLC Safety relay Type of evaluation: - Safe control system - Safety relay Maximum number of switches 1 CET-AR Consisting of a safety switch with internal evaluation electronics and an actuator. The CET-AR can be connected in series (up to 20 units). CES-AR Safe PLC Safety relay Type of evaluation: - Evaluation unit CES-AR - Safe control system - Safety relay Maximum number of switches 1...20 CET-AS AS-i monitor Consisting of a safety switch with internal evaluation electronics and an actuator. The CET-AS is suitable for direct connection to the AS-i bus. AS-i coupling module Type of evaluation - AS-i Safety at work Maximum number of switches 1...31

CET in detail Plunger for releasing the guard locking Recess with integrated read head Actuator made of rustproof steel with integrated transponder Mechanical guard locking with 6,500 N Sturdy insertion slide of rustproof steel permits use on large and heavy doors Actuating head adjustable in four directions for use on doors hinged on the right or left Escape release (optional) for releasing the guard locking from within the danger area without tools Mechanical release for releasing the guard locking with the aid of a tool Detailed diagnostic function via LEDs Slim design, ideal for space-saving installation Front wire release (Bowden) (optional) permits remote release of the guard locking via a pull rope Different connection options (M12, M23, AS-i) simplify wiring work Robust die-cast metal housing, ideally suited for harsh environments Sturdy double insertion (optional) slide made of rustproof steel for use on swing doors or rotary tables

www.euchner.com Securing two hinged doors The advantages of CET at a glance Combination of mechanical guard locking and transponder technology Guard locking with guard lock monitoring Suitable for process protection and the protection of personnel, even in case of overtravelling machine movements Uniquely coded actuator Effective protection against tampering Category 4 / PL e with one switch Plug connectors mean little wiring effort High locking force up to 6,500 N Robust metal housing for harsh environment Also suitable for heavy doors High degree of protection IP67 Actuator with large freedom of movement No precise door adjustment necessary Securing a sliding door Securing a hinged door 114133-08-09/17 Subject to technical modifications; no responsibility is accepted for the accuracy of this information. EUCHNER GmbH + Co. KG TA EUCHNER GmbH + Co. KG Kohlhammerstraße 16 70771 Leinfelden-Echterdingen Germany Tel. +49 711 7597-0 Fax +49 711 753316 info@euchner.de www.euchner.com