Bevent Rasch BSKC6. - Fire /06/17

Similar documents
Bevent Rasch RABC-VAV. - Fire /03/2018

Bevent Rasch. FIDm. - Fire /11/2018

Bevent Rasch. FIDs. - Fire /05/18

ESAR SMOKE CONTROL DAMPER» TECHNICAL CATALOGUE

Fire damper ETPR Instructions for Installation, Operation and Maintenance 10/2016

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

KOMFORT EC DB Suspended heat recovery air handling units

MAXI CENTRALIZED VENTILATION WITH HEAT RECOVERY

Fire/Smoke damper EKO-SRBG2

Circular Fire Damper Cartridge

BSK-RPR Fire Damper. Additional operating instructions according to

Type FKS-EU COMPACT DIMENSIONS, IDEAL FOR RESTRICTED SPACES. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FKS-EU

TopMaster Air Handling unit. Technical data

Type FK-EU FOR DIVERSE APPLICATIONS. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FK-EU

VL120. Multi blade smoke evacuation damper 120' C-NT-V24-A 01/2016

BKA-EN Fire Damper. Additional operating instructions according to

Fire damper DESIGN GENERAL FIRE CELL DIVISION DISTRIBUTION OF RESPONSIBILITIES FIRE PROTECTION DOCUMENTATION HAGAB FIRE DAMPER DESIGN

TEKNISK DOKUMENTATION VENTILATION BG BURCHARTH A/S

TURBO HOODS. Product Brochure

European Technical Assessment ETA 17/1007 of 02/05/2018

LX-5 FIRE DAMPER. EI 120 (ve ho i o) S EN A1:2010. Damper tightness class: 4 EN 1751:2002. Casing tightness class: C. Fulfils requirements

Type FKRS-EU COMPACT DIMENSIONS, IDEAL FOR RESTRICTED SPACES. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FKRS-EU

eco PREMIUM ENERGY RECOVERY UNIT» Technical instruction

CONDOR. Supply air ceiling QUICK FACTS

CHILLED BEAM CASSETTE IQ STAR LYRA

HOTEL CHILLED BEAM IQ STAR SILENCIA

TECHNICAL SPECIFICATION

Series VENTS VUT R WH ЕС

KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S. Heat and Energy Recovery Ventilators

Fire dampers. For diverse applications

DUCTGARD. Duct Mounting Smoke and Fire Control Dampers

CUMULUS CUMULUS. Key figures. Construction. Function Integrated chilled beams

INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL

Smoke Master SMIA Compact pressurisation and smoke exhaust system

Smoke Fire Damper Interface (230V)

Swegon CASA W130. Ventilation unit with counter-flow plate heat exchanger HOME VENTILATION

Air handling unit. REC Temovex 400S-EC-RS. Experts on indoor climate in low-energy houses

ROOFMASTER STEF-HT ROOF FAN

Bruksanvisning Directions for use

CE-marked ESAD - Smoke Control Duct System Installation instructions 08/2013

Smoke extract fan SMHA HATCH

UV-TURBO HOODS. Product Brochure

Orion-PTV LØV-R with Sirius

290 on. 286 on. Comfortable climate with pre-heated, filtered supply air. Fresh air boxes ALB WW MODEL WITH WARM WATER HEATING

Technical Data. Dimensions

Orion-LØV LØV-R with Sirius

GLEC exhaust FAN. Air Comfort. Air movement. Duct & Box Fans

Swegon CASA R120. Ventilation unit with rotary heat exchanger HOME VENTILATION

AXIS-QA G TUBO-M/MZ AXIAL FANS. Axis / Tubo OPERATION MANUAL

ML/MLT. User s Manual 17E-30E. Desiccant dehumidifiers ML17E-MLT30E with electric heater for reactivation

Air Handling Unit. REC Temovex Blue 4 NEW! Experts on indoor climate in low-energy houses

ADAPTER FOR VENTILATION DUCT BWP-143A-SS (STAINLESS STEEL)

Orion-LØV LØV-R with Sirius

Technical Data. Dimensions

AIR HEATING UNIT HEATMASTER ACJB INSTALLATION, OPERATION, MAINTENANCE AND SPARE PARTS

Gas-fired unit heaters for indoor installation

Heat Recovery Unit HERU. web-version

for a considerable reduction of the supply air temperature which, in turn, reduces the air conditioning

F17W44_MFB_F_EN INSTALLATION INSTRUCTIONS

Orion-Opus LØV-R with Sirius

Type TDF-SilentAIR WITH VERY LOW SOUND POWER LEVEL FOR COMFORT ZONES, WITH FIXED AIR CONTROL BLADES

SmartShelter Room. Technical Description. Version 1.1 Jul. 2017

INSTALLATION OPERATION & MAINTENANCE INSTRUCTION HEAT RECOVERY UNITS VHR MODELS

COMPACT Air & Heat. Contents

INLINE CENTRIFUGAL FAN. Centro-M OPERATION MANUAL

iq Star LYRA II chilled beam cassette

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

CONFIGURABLE CROSS-FLOW HEAT RECOVERY UNITS ENERGY-BOX HE

Homepage > Products > Decentralised ventilation systems > Vertical units > Type FSL-V-ZAB/SEK FSL-V-ZAB/SEK

TopMaster Air Handling Unit

Homepage > Products > Grilles and Diffusers > Ceiling diffusers > Design ceiling swirl diffusers > Type ADD. Type ADD

IRBB Inert gas damper

Beck. The differential pressure transmitter for air

Ionisation single-tube smoke detector for duct mounting

Direct Vent Training & Installation Instructions for Venting 40/50 gallon models Telescoping Vent Kit (standard)

Fresh air unit ALB. ALB it s simple and so easy! Air supplied through a heater and filter in a single unit.

HEAT RECOVERY AIR HANDLING UNIT

Operating Manual MS220KA and MSR220KA

Smoke Damper Interface (230V)

Fire Damper Interface (230V)

Kezdőlap > Termékek > Tűz és füst elleni védelem > Füstmentesítő csappantyúk > Típus EK-EU. Típus EK-EU

Type UB-2502A and UB-3002A Forced-Air Heater

Roof top SPACE RPC 450Z R407C M011

Extraction systems for the electronic industry. Soldering workstations Soldering smoke extraction systems

QAF63.2-J QAF63.6-J. Frost detectors. for use on the air side

VA 150 A, VA 150 P WINDOW EXTRACT FAN. Installation and Wiring Instructions V/1/50Hz

Product Data Sheet 4114 N/17HH-218. The engineer's choice

Technical data Chimney fans, controllers & accessories in systems for multiple heating appliances

Ceiling swirl diffusers

Ceiling swirl diffusers

INSTALLATION AND SERVICE MANUAL

TKM 50 HE. High efficiency in air treatment

Customer id 2452 Project 1152 Unit 189 ACON From Inspection Side. Unit name AHU-22 R.05 Supply air EU m³/sec Exhaust air

Fire Damper Interface (24V)

SPXA / SPXA-HP Series Single Package Vertical Unit Straight Cool and Heat Pump 3/4 through 2 tons, up to 10 kw Electric Heat

INSTALLATION AND SERVICE MANUAL

FRESHBOX 100. Single-room heat recovery unit. Air flow up to 59 CFM Heat recovery efficiency up to 96 %

ELECTRONIC FIREPLACE DAMPER

Schueco Fire and Smoke Protection Systems

PRODUCT DATA COMBI 300 POLAR BY NILAN. Ventilation with passive & active heat recovery. Active heat recovery. Passive heat recovery.

Transcription:

Bevent Rasch - Fire - BSKC6 19/06/17 Fire resistance class EI60/EI60S Sizes from 100 mm to 630 mm Prefitted safety actuator 24V or 230V Low weight Easy installation CE-marked building product according to 15650:2010 Available in MagiCAD www.bevent-rasch.com

EI60 Quick facts Fire resistance class EI60/EI60S Sizes from 100 mm to 630 mm Prefitted safety actuator 24V or 230V Low weight Easy installation CE-marked building product according to 15650:2010 Available in MagiCAD Use Damper in combination with walls or floor systems for fire separation of heating, ventilation and air conditioning installations in buildings. In accordance with the harmonised European standard EN 15650:2010. In designs according to associated documents, installation instructions and when the damper is used in combination with smoke detectors and monitoring system (MRB), or the like, the spread of fire/combustion gases is prevented. No further action against the spread of fire/combustion gases is required. Performance EC certificate according to EN 15650:2010 402-CPD-SC0900-13 Installation BSKC6 is installed in fire cell separating walls or floor systems, alternatively in horizontal insulated ducts going through fire cell separating building elements, according to the adjoining installation instructions. Should not be installed outdoors or in damp areas. BSKC6 is always supplied with an electric safety actuator with spring return complete with thermal sensor with pushbutton for local manual operating test. The sensor disconnects the power to the actuator if the temperature exceeds 72 C inside or outside the damper. 24V actuators are always used in connection with the MRB monitoring system. Dampers can also be supplied with electric actuator 230V. Note that the BSKC6 damper is always supplied with an actuator. Activation According to Boverket s Building Regulations smoke detectors must be verified according to SS-EN 54-7 to activate dampers. The mandatory thermal sensor closes the damper at 72 C according to ISO 10294-4. Classification of fire resistance according to EN 13501-3 EI60 (ve ho i < > o) S For complete classification, see the Declaration of Performance. 2 BORÅS Tel +46 (0)33-23 67 80 STOCKHOLM Tel +46 (0)8-54 55 12 70

EI60 Control and monitoring When the damper is used to prevent the spread of fire and combustion gases it must be closed via impulses from the smoke detector. This must be fitted in the ventilation duct in the proximity of the damper or in another suitable location. Smoke detectors are monitored by means of Rasch s MRB system or the like. The MRB monitoring system also performs automatic operating checks on the damper every 48 hours and is designed so that faults are indicated immediately and the damper closes. See www.bevent-rasch.com for further details. Size Ø100-630 mm. Design BSKC6 is supplied complete with factory mounted, maintenance-free, 24V electric safety actuator with thermal sensor featuring built-in signal contacts to indicate the damper position. Spiral duct connections. Specification Example: - 400-1 - 1 Size, nom. diameter ØD mm Material Galvanized sheet steel = 1 Stainless AISI 3041 EN 1.4301 = 2 Stainless AISI 316L EN 1.4404 = 3 Electric 24V with thermal sensor = 1 Electric 230V with thermal sensor = 3 Electric 24V incl. RCTU = 5 Note. Factory fitted actuator always included. Material and surface finish Casing and components of galvanized steel sheet according to environmental class C3. Fabric seals. EPDM spiral duct connections. Blade and casing of solid fire protection materials. Accessories BRMK Installation kit BRTO Wire mesh grille RCKB Connection box RCDU MRB system, max 2 dampers RCBK4 MRB system, max 4 dampers RCMU8 MRB system, max 8 dampers RCKD/-RD Smoke detectors RCTU/RCTC MRB3 system, max 236 dampers BORÅS Tel +46 (0)33-23 67 80 STOCKHOLM Tel +46 (0)8-54 55 12 70 3

EI60 Dimensions and weight max 90 max 55 max 200 Ød Ød +105 100 257 A Size Ød 100 125 160 200 250 315 400 500 630 A 35 75 125 190 Weight, incl, actuator, kg 3,4 3,7 4,3 5,0 6,0 7,2 10,6 13,0 17,0 - damper sizes BLF-T is supplied to damper sizes Ø100-315 mm. BF-T is supplied to damper sizes Ø400-630 mm. Wiring diagram N L1 1 2 M Electrical data (values in brackets refer to 230V) type BF... BLF... Sizing, max... 10 VA (12.5 VA) 7 VA (7 VA) Running time: motor opening, max... approx. 120 s 40-75 s - spring return, max... approx. 20 s Protection class... IP 54 Power supply... 24V~ ±20%, 50/60Hz 24V= ±10% (220-240V~, 50/60Hz) Ambient temperature... -30 to +50 C Safety temperature... -30 to +75 C (24 hrs. guaranteed safety) Tripping temperature thermal sensor... 72 C End position contacts - load 300 mw... min 1 ma/5v=, max 100 ma/250v~ After exceeding the above values it applies: - load > 300 mw... min 100 ma, max 3 A/250~ Sound level when opening approx 45 db(a) Sound level when closing approx 62 db(a) Chart indicates in the de-energized state 1 2 3 4 5 6 5 C 80 O BAE72-S Tf1 Tf2 Thermal sensor 4 BORÅS Tel +46 (0)33-23 67 80 STOCKHOLM Tel +46 (0)8-54 55 12 70

EI60 Size chart Total pressure drop, Pa 200 100 50 40 30 20 Sound power level L Wt, db Size 100 125 160 200 250 315 400 500 50 db 60 db 55 db 70 db 65 db 630 45 db 10 10 20 30 40 50 100 200 300 500 1000 2000 3000 10.000 Air flow, l/s Sound data Correction of sound power level, L Wok, in octave band L wok = L w + K ok Correction, K ok Size Ø mm Centre Frequency Hz 63 125 250 500 1000 2000 4000 8000 100-4 -6-7 -12-17 -24-26 -33 125-5 -5-8 -14-22 -25-27 -35 160-5 -4-8 -13-17 -20-28 -34 200-3 -6-10 -14-15 -19-27 -40 250-1 -11-15 -20-22 -23-29 -37 315-2 -8-11 -12-13 -19-23 -29 400-2 -8-14 -12-15 -22-30 -41 500-2 -8-13 -13-15 -21-28 -36 630 0-15 -23-23 -28-35 -41-48 Tol. ± db 2 3 4 4 6 7 9 9 BORÅS Tel +46 (0)33-23 67 80 STOCKHOLM Tel +46 (0)8-54 55 12 70 5

EI60 Installation instruction Supporting construction (wall or floor) in fire resistance class EI60. Damper s fire resistance class: EI60 (ve ho i <-> o) S. EC certificate 0402-CPD-SC0900-13 Option 1 Option 2 Seal acc. to section 3 Seal with fire stopping sealant, e.g. Intumex AN (Possible protective grille, see section 5) Seal with fire stopping sealant, e.g. Intumex AN Protective grille, see section 5 Fastening lugs Plug and screw M8x40 mm in concrete. d+40 Min. thickness 125 mm Brackets Concrete wall or drywall panel insulated with mineral wool 40kg/m3 or equivalent fire class EI60 Fastening lugs Metal anchor 6x50 mm Min. thickness 95 mm Seal acc. to section 3 Protective grille, see section 5 Brackets Floor structure in lightweight concrete or equivalent fire class EI60 d+40 Options 1 and 2 1. Install and join the damper in the ventilation duct that ends at the wall or floor face (after the lead-through). 2. The damper is secured flat and tight using fire stopping sealant (Intumex AN) against the wall/floor structure with the fastening lugs, which are opened out. 3. Sealing is carried out by caulking with mineral wool, min 40 kg/m 3. 4. Use brackets to fasten the duct to the wall. 5. If fire damper is not connected to the duct system, fit non-combustible grilles designed for the damper on the unconnected sides. The minimum distance between the damper blade in the open position and the grille is 50 mm. 6. Install the thermal sensor with the sensor body in the air flow without obstructing the movement of the damper blade. 7. Install the duct system according to applicable requirements. Minimum distance between dampers must be 200 mm. Minimum distance to joist structure/wall must be 75 mm. 6 BORÅS Tel +46 (0)33-23 67 80 STOCKHOLM Tel +46 (0)8-54 55 12 70

EI60 Installation instruction Installation in horizontal duct. Damper s fire resistance class: EI60 (ve i < > o) S. EC certificate 0402-CPD-SC0900-13 Max. 1000 mm Seal acc. to section 2 Support of duct, see section 5 Insulation equivalent to fire resistance class of the supporting construction d+40 Brackets Seal with fire stopping sealant, e.g. Intumex AN (Possible protective grille, see section 3) 13-0184_ENG / June 2017 mediacad.se 1. Install the damper in the duct. 2. going through supporting construction, is fastened using brackets. Seal according to applicable requirements, such as caulking with mineral wool, min 40 kg/ m 3 and fire stopping sealant. 3. If fire damper is not connected to the duct system, fit non-combustible grilles designed for the damper on the unconnected sides. The minimum distance between the damper blade in the open position and the grille is 50 mm. 4. Install the thermal sensor with the sensor body in the air flow without obstructing the movement of the damper blade. 5. is fastened/supported according to applicable requirements. 6. Insulate the duct according to applicable requirements using instructions from the insulation supplier, min. 80 mm and 55 kg/m 3. Note that insulation must cover the damper. Minimum distance between dampers must be 200 mm. Minimum distance to joist structure/wall must be 75 mm. The damper spindle may be installed in any position. BORÅS Tel +46 (0)33-23 67 80 STOCKHOLM Tel +46 (0)8-54 55 12 70 7