CT CABINET AND UTILITY METERING WELL AND BOOSTER PUMP CONTROL 12"x12" WIREWAY 200A MCB 200A, 120/208V, 3Ø, 4W BOARD TVSS CIA ALARM 400A, DOUBLE-THROW SWITCH PORTABLE GENERATOR CONNECTION ENCLOSURE EXISTING UNIT HEATER TO BE REMOVED. TYPICAL FOR 2. REMOVE ASSOCIATED CONDUIT AND WIRE BACK TO BOARD AND LABLE SPARE. LIGHT FIXTURE TO BE REMOVED. TYPICAL FOR 2. REMOVE ASSOCIATED CONDUIT AND WIRE BACK TO BOARD. ELECTRICAL DEMOLITION PLAN SCALE: 1" = 1' - 0" N REMOVE AND RELOCATE ALL ELECTRICAL WIRING IN OR ON WALLS BEING REMOVED EXISTING BOOSTER PUMPS FLOOD LIGHTS TO BE REMOVED. REMOVE ALL CONDUIT AND WIRE BACK TO SOURCE. LIGHT SWITCH TO BE REMOVED LIGHTS FIXTURE TO BE REMOVED. REMOVE ALL CONDUIT AND WIRE BACK TO SOURCE. LEGEND SYMBOL DESCRIPTION WORK TO BE REMOVED EXISTING NEW WORK T THERMOSTAT MD MOTORIZED DAMPER EXHAUST FAN #1 UH-1 UNIT HEATER #1 CIRCUIT HOMERUN (120V) TO BOARD CIRCUIT HOMERUN (208V/1Ø) TO BOARD 120/208V 3Ø 4W BOARD GFI GROUND FAULT INTERRUPT S SINGLE-POLE SWITCH # MOTOR, # INDICATES HORSEPOWER 30/- DISCONNECT SWITCH ENCLOSED CIRCUIT BREAKER WP WEATHERPROOF MCB MAIN CIRCUIT BREAKER DUPLEX RECEPTACLE MOTOR STARTER NOTE: ALL WORK IS NEW UNLESS NOTED OTHERWISE. ELECTRICAL DEMOLITION PLAN AND LEGEND E-1
N DUPLEX TRANFER PUMPS UH-1 5 5 LE ULTRASONIC LEVEL SENSOR A A A WELL AND BOOSTER PUMP CONTROL 12"x12" WIREWAY BAG FILTERS 200A CIRCUIT BREAKER EXISTING BOOSTER PUMPS 200A, 120/208V, 3Ø, 4W BOARD CT CABINET AND UTILITY METERING SIX (6) TRAIN ION EXCHANGE FILTRATION SYSTEM. NO ELECTRICAL REQUIREMENTS, ALL INSTRUMENTS BATTERY OPERATED. TVSS 60A ENCLOSED CIRCUIT BREAKER FOR DUPLEX TRANSFER PUMP CONTROL CIA ALARM GFI T GFI EXIT S S 48" AFF 400A, DOUBLE-THROW SWITCH FAN STARTER PORTABLE GENERATOR CONNECTION ENCLOSURE NOTE: PROVIDE QTY. 5, 50' LENGTHS OF PORTABLE GENERATOR CABLE. CABLES SHALL BE COLOR CODED BLACK, RED, BLUE, WHITE AND GREEN (208V, 3Ø, NEUTRAL AND GROUND). CABLE SHALL BE #4/0, TYPE W, 600V, COPPER CABLE RATED 400A, TERMINATED WITH FEMALE AND MALE SERIES 16 CAM-LOCK CONNECTORS. AS MANUFACTURED BY LEX PRODUCTS. B GFI WP NOTES: 1. PROVIDE 2 #12, 1 #12 GND, TYPICAL FOR EACH 120V AND 208V, 1Ø CIRCUIT HOMERUN FROM EQUIPMENT TO BOARD. 2. REUSE EXISTING 20A/1P CIRCUIT BREAKER FOR NEW LIGHTING. 3. PROVIDE 3-20A/1P CIRCUIT BREAKERS FOR AND RECEPTACLE CIRCUITS. 4. PROVIDE 3-20A/2P CIRCUIT BREAKERS FOR UNIT HEATER CIRCUITS. 5. EXTERIOR LIGHTING CIRCUITS ARE SHOWN DIAGRAMATICALLY, ALL CONDUIT AND WIRE SHALL BE RUN INTERNAL TO THE BUILDING. ELECTRICAL INSTALLATION PLAN SCALE: 1" = 1' - 0" LIGHTING FIXTURE SCHEDULE TYPE LAMPS WATTS MOUNTING VOLTAGE FIXTURE MANUFACTURER AND CATALOG NUMBER REMARKS A 39W LED CEILING 120V LITHONIA FEM4 LED LOW-PROFILE AND GASKETED 4,000 LUMENS, 4100 K, FROSTED LENS B 19W LED WALL 120V LITHONIA TWS LED WALL LUMINAIRE 1017 LUMENS, 5000 K, PHOTOCELL, DARK BRONZE LITHONIA OFLR 9 P DUSK-TO-DAWN C 32W LED WALL 120V 2067 LUMENS, PHOTOCELL, BRONZE FLOODLIGHT, 3 ADJUSTABLE HEADS EXIT LITHONIA ECR LED M6 COMBINATION EMERGENCY LIGHTING AND EXIT, 120V, RED LETTERING. E-2 ELECTRICAL INSTALLATION PLAN C UH-3 UH-2 DUPLEX TRANSER PUMP CONTROL C 500 GALLON RECEIVING TANK MD
DUPLEX TRANSFER PUMP SCHEMATIC DIAGRAM TRANSFER PUMPS TAP EXISTING FEEDER FOR DUPLEX TRANSFER PUMP CONTROL. PROVIDE POLARIS INSULATED SPLICE KITS AS REQUIRED. 5 5 3 #10 1 #10 GND ULTRASONIC LEVEL SENSOR (500 GALLON RECEIVING TANK) 4-750 AL + GND 12"x12" WIREWAY 4 #6 1 #10 GND 1"C FACTORY CABLE, 400A 120/208V 3Ø, 4W INCOMING UTILITY SERVICE 400A CT CABINET 400A DOUBLE-THROW SWITCH (MAIN DISCONNECT) 60A/3P UTILITY METER PAN CIA ALARM ALARM MONITORING NOTES: 1. CONTRACTOR TO ENGAGE THE SERVICES OF THE TOWN'S ALARM MONITORING COMPANY TO MODIFY EXISTING ALARM TO ACCEPT NEW INPUTS. 2. CONTACT "CIA" COMMERCIAL INSTRUMENTS & ALARMS, INC. 845-896-9500. M 200A/3P DUPLEX TRANSFER PUMP CONTROL PORTABLE GENERATOR CONNECTION ENCLOSURE WELL AND BOOSTER PUMP CONTROL 14 #14 COMMON ALARM PUMP 1 FAILURE PUMP 2 FAILURE HIGH LEVEL ALARM LOW LEVEL ALARM 4 SPARE #14 PORTABLE GENERATOR NOTE: TOWN OWNED PORTABLE EMERGENCY GENERATOR IS 110KW STANDBY RATED MULTIQUIP MODEL DCA125SSJU4I WHISPERWATT MQ POWER SERIES. 110KW GENERATOR CAPACITY MATCHES 400A, 208V SERVICE SIZE TO CARRY 200A ALL BUILDING LOADS. 120/208V 3Ø, 4W BOARD EXHAUST FAN SCHEMATIC DIAGRAM T THERMOSTAT 2 #14 MD MOTORIZED DAMPER 2 #12 1 #12 GND BOARD NOTES: 1. PROVIDE SIZE 00, 120V ENCLOSED MOTOR STARTER WITH H-O-A SWITCH. 2. PROVIDE OVERLOAD HEATERS, SIZE AS REQUIRED. 3. THERMOSTAT SHALL BE WIRED TO AUTO MODE. 4. PROVIDE HONEYWELL, MODEL T4051B, 120V LINE VOLTAGE THERMOSTAT FOR COOLING APPLICATION. 2 #12 1 #12 GND CAULK ALL AROUND WITH SILICONE SEALANT PRIOR TO INSTALLING BUSHING FLANGED TYPE SEALING BUSHING AS SPECIFIED GROUT OPENING WITH NON-SHRINK GROUT CONDUIT CONCRETE WALL OR FOUNDATION LINK SEAL IS ACCEPTABLE CORE DRILLED HOLE INSTALL O-Z GEDNEY CABLE WATER TIGHT SEALS IN EACH CONDUIT THAT PENETRATES BUILDING WALL TYPICAL SLEEVE DETAIL FOR EXISTING WALL PENETRATION ELECTRICAL DIAGRAMS AND DETAILS E-3
EXISTING UNIT HEATER TO BE REMOVED. TYPICAL FOR 2. MECHANICAL DEMOLITION PLAN SCALE: 1" = 1' - 0" N LEGEND SYMBOL DESCRIPTION WORK TO BE REMOVED EXISTING NEW WORK T THERMOSTAT MD MOTORIZED DAMPER ESP EXTERNAL STATIC PRESSURE DENOTES EXHAUST FAN #1 UH-1 DENOTES UNIT HEATER #1 NOTE: ALL WORK IS NEW UNLESS NOTED OTHERWISE. MECHANICAL DEMOLITION PLAN M-1
16"x16" LOUVER BDD UH-1 SEE DETAIL DRAWING M-3 SEE DETAIL DRAWING M-3 FAN AND LOUVER ASSEMBLY TO BE MOUNTED 90" AFF MECHANICAL INSTALLATION PLAN SCALE: 1" = 1' - 0" N T UH-3 M-2 MECHANICAL INSTALLATION PLAN UH-2 12"x10" LOUVER SEE DETAIL DRAWING M-3 MD
PLYWOOD WALL AND VINYL PLYWOOD WALL AND VINYL 2" X 4" WOOD STUD SUPPORT CONNECTED TO 2" X 6" VERTICAL WOOD BEAMS CAULK ALL AROUND (TYP.) CLIP ANGLE FIXED LOUVER WITH DRAINABLE BLADES ALUMINUM BIRD SCREEN FURNISH WITH LOUVER BIRD SCREEN CAULK ALL AROUND (TYP.) CLIP ANGLE SCREW FASTENER (TYP.) 2" X 4" WOOD STUD SUPPORT CONNECTED TO 2" X 6" VERTICAL WOOD BEAMS PLYWOOD WALL AND VINYL 2" X 4" WOOD STUD SUPPORT CONNECTED TO 2" X 6" VERTICAL WOOD BEAMS LOUVER DETAIL FIXED LOUVER DETAIL UNIT NO. CFM ESP (WG) WEIGHT (LBS) FAN RPM POWER (W) MOTOR HP V/P/Hz EXHAUST FAN SCHEDULE ARRANGEMENT TYPE MFR & MODEL NO. REMARKS 712 0.1 42 1550 0.094 0.05 120/1/60 DIRECT DRIVE PROPELLER COOK 10S15D UNIT HEATER SCHEDULE UNIT NO. kw AMPS ELECTRICAL WEIGHT MFR & MODEL NO. REMARKS UH-1 3 15 208/1/60 27 QMARK MUH0381 UH-2, UH-3 1.5 208/1/60 18.5 QMARK 2548W ELECTRIC UNIT HEATER SUPPORT DETAIL (TYP.) FLOOR SLAB ±7'-0" UNIT HEATER WALL BRACKET ANCHOR TO WALL ±20 1/2" EXTERIOR WALL ROOF FAN COLLAR SUPPORT FROM PLENUM 16 GAUGE S.S. SHEET PLENUM TO EXTEND THROUGH WALL 2"x2"x 4" 1 S.S. ANGLE ALL SIDES PATCH WALL LINTEL 12"x12" ACCESS DOOR (HINGED) FIXED LOUVER MOTOR MOUNTED ON VIBRATION ISOLATOR. WIRE MESH INLET GUARD BACKDRAFT DAMPER 14" MIN. PATCH EXISTING WALL TO MATCH LOUVER AND SLEEVE OPENING SIZE (TYP.) WALL 2"x2"x1/4" S.S. WELDED ANGLE FRAME FOR SUPPORT NOTE: ALL ANGLES AND FASTENERS TO BE 316 S.S. PROPELLER FAN MOUNTING DETAIL DETAILS AND SCHEDULES M-3