Similar documents
Ho-Chunk Gaming THUNDERBIRD ENGINEERING, INC. MILWAUKEE: (414) MADISON: (608)

REFLECTOR PANS FOR HINGED ELEMENTS CONNECTOR BLOCK KIT TRIM RINGS FOR ABOVE PANS CONNECTOR BLOCK RANGE CORD REFLECTOR PANS FOR PLUG-IN ELEMENTS

DRAWING SCHEDULE TAB REQUIREMENTS BY EQUIPMENT TYPE TYPE OF EQUIPMENT DESCRIPTION COMPONENT TAB REQUIREMENTS

UNIVERSITY OF ROCHESTER DESIGN STANDARDS NOVEMBER 1, 2013

Construction Standards Page Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

ELECTRICAL SYMBOLS AND ABBREVIATIONS NOT ALL SYMBOLS, DEVICES OR ABBREVIATIONS MAY BE USED

FIRE ALARM: BY OTHERS, IF REQUIRED.

FIRE ALARM: BY OTHERS, IF REQUIRED.

1.1 This section applies to air handling units for HVAC Systems.

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units

Special Provision No. 682S27 June This Special Provision refers to the following standards, specifications or publications:

GARCIA GALUSKA DESOUSA Consulting Engineers

HVAC LEGEND HVAC ABBREVIATIONS PLUMBING LEGEND PLUMBING ABBREVIATIONS PRELIMINARY NOT FOR CONSTRUCTION

Installation Instructions

Industrial Space Heating Direct Gas-Fired Heating. Greenheat 50/50 Recirculation

CATALOG OF REPLACEMENT PARTS

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

Direct Fired Heater Model AD Specification

A. General: Refer to paragraph entitled "SUBMITTAL" in Section Include the following data:


Explosion Proof Light Watt Metal Halide - Class 1 Div 1 & Class 2 Div 1

AIR HANDLING UNITS Vibration Isolation Air Filtration Equipment Ductwork.

SECTION AIR DUCT ACCESSORIES

SECTION PANELBOARDS Painting Wire and Cable Overcurrent Protective Devices.

Vanilla Box Design Criteria

LIGHT LEVEL REQUIREMENTS MINIMUM ACCEPTABLE FOOT CANDLES

RS Chimney Fan For Gas & Oil Applications. Installation & Operating Manual USA CAN

Direct Gas-Fired Make-Up Air

Port of Portland Conveying Equipment Guidelines

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

Linear Floor Heaters

CLIMATAIR PENTHOUSE AIR HANDLING SYSTEMS

Technical Manual. VFD / Cabinet Heater Upgrade 110 VAC Heater to 12 VDC Heater. Provided by: Chart Inc.

M001. Revenue Services ISSUED FOR CONSTRUCTION SEPTEMBER. 2, East State Parkway Schaumburg, Illinois Do Not Scale Drawings

.4 Do complete installation in accordance with latest Electrical Bulletins of the local inspection authority.

SECTION (15833) - HVAC POWER VENTILATORS

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

SUBMITTAL SCHEDULE & DATA

TECHNICAL SPECIFICATIONS

Leviton Combination Switch And Tamper Resistant Outlet Wiring Diagram

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

Modular Supply Make-Up Air Unit

UNIT HEATER CATALOG. Form C-UH-0516 COMMERCIAL/INDUSTRIAL HEATERS RESIDENTIAL GARAGE HEATERS. FUEL Natural Gas Propane Fuel Oil

CR1 Series Triton Corrosion Resistant Washdown Heaters

SECTION PANELBOARDS. A. Drawings and general provisions of the Contract, including General and Supplementary Conditions, apply to this Section.

McQuay. Roofpak Roof Mounted Air Handler Draw- Through. RDS Size: 900 Vintage: B. Last Manufactured: 1998

FX5 Series Explosion-Proof Electric Air Heaters

Building Division 201 SE 3 rd STREET (Second Floor) OCALA, FL Phone: (352) BUILDING CODE GUIDELINES FOR ELECTRICAL INSPECTIONS

DEMOLITION GENERAL NOTES As-built conditions have been determined from Record Drawings (if they exist), field investigations (accessible areas and

JFT Flight Machine. JFT Flight Machine. Models. Options. Standard Features. JFT Flight Machine

ENGINE GENERATORS AND ACCESSORIES

LABGARD NU-602 CLASS II TYPE A2 ANIMAL HANDLING BIOLOGICAL SAFETY CABINET

Electrical Design Guidelines Table of Contents

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION EXHAUST FANS

SECTION (15820) - AIR DUCT ACCESSORIES

SPXA / SPXA-HP Series Single Package Vertical Unit Straight Cool and Heat Pump 3/4 through 2 tons, up to 10 kw Electric Heat

OWNER S MANUAL MODULAR DIRECT CONNECTED TILTING STEAM JACKETED KETTLE

BUILDER S PRE-INSPECTION CHECKLIST

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) For FVO-400TRLT INDIRECT FIRED HEATER TRAILER

3000 Series Fan Forced Ceiling Heater Series Commercial Fan Forced Ceiling Heater

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

SWP. (Models SWP08 through SWP20) IMPORTANT! Read before proceeding! OPERATION & MAINTENANCE MANUAL

Electricity Unit Notes. Agriculture Mechanics I

Installation Instructions. (Applicable to all front door models)

SPXB / SPXB-HP Series Single Package Vertical Unit Straight Cool and Heat Pump 3/4 through 2 tons, up to 10 kw Electric Heat

SPXR-A / SPXR-HP-A Series Single Package Vertical Unit Straight Cool and Heat Pump 3/4 through 2 tons, up to 10 kw Electric Heat

TYPICAL CPA SPECIFICATIONS

FT1000 ENERGY RECOVERY WITH BLOWER DRYER FLIGHT-TYPE DISHWASHER

IMPORTANT WARNINGS IMPORTANT SAFETY INSTRUCTIONS

Model UDAP. Power Vented, Low Static Axial Fan Commercial/Industrial Unit Heaters DESCRIPTION STANDARD FEATURES OPTIONAL FEATURES - FACTORY INSTALLED

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

HVAC Equipment Access Equipment Location

SECTION AIR HANDLING UNIT

COMMON WORK RESULTS FOR ELECTRICAL: Basic Electrical Materials Methods

CABINET PARTS REFRIGERATOR

Models. Options. Standard Features. LoH 2 O

SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED

SECTION DUCTWORK

SPECIFICATION DELETED SECTION CENTRIFUGAL HVAC FANS

MXn RACK OVEN SPARES MANUAL MACHINE NO.FG164

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES

SECTION KITCHEN HOOD AND DUCT FIRE SUPPRESSION SYSTEM

TABLE LIGHTING POWER DENSITIES FOR BUILDING EXTERIORS ASHRAE Uncovered Parking Areas. Building Grounds. Walkways 10 feet wide or greater

Technical Manual Binair Monobloc Heat Pump

CABINET PARTS REFRIGERATOR. For Models: ED25PQXFW00, ED25PQXFN00 (White) (Almond) Litho In U.S.A. (mdg) 1. Part No

INSTALLATION INSTRUCTIONS

A. American National Standards Institute (ANSI) : Establishes requirements applicable to certifying direct gas-fired heaters.

VentZone Systems VentZone Zoned IAQ with Heat Recovery Kits

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

Electric Floor Warming Systems Installation and Operation Instructions. Mat Heating Systems and Cable Heating Systems. UL Listed for USA and Canada

Library stacks and records storage 150 LB/SF live load

B.C.S. Shop Heaters 26, 30 & 36 (36 shown)

High Plume Blowers Suggested Specification Section (Master Format 1996) Suggested Specification Section (Master Format 2004)

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

CABINET PARTS For Model: ED5GTGXNQ14, ED5GTGXNB14 (White) (Black)

Cabinet Unit Heaters Steam / Hot Water

breeze easytm model # F100-1W

TECHNICAL SPECIFICATIONS

HVAC HEATING PRODUCTS

DARTMOUTH COLLEGE DESIGN March 15, 2003 & CONSTRUCTION GUIDELINES

Transcription:

CT CABINET AND UTILITY METERING WELL AND BOOSTER PUMP CONTROL 12"x12" WIREWAY 200A MCB 200A, 120/208V, 3Ø, 4W BOARD TVSS CIA ALARM 400A, DOUBLE-THROW SWITCH PORTABLE GENERATOR CONNECTION ENCLOSURE EXISTING UNIT HEATER TO BE REMOVED. TYPICAL FOR 2. REMOVE ASSOCIATED CONDUIT AND WIRE BACK TO BOARD AND LABLE SPARE. LIGHT FIXTURE TO BE REMOVED. TYPICAL FOR 2. REMOVE ASSOCIATED CONDUIT AND WIRE BACK TO BOARD. ELECTRICAL DEMOLITION PLAN SCALE: 1" = 1' - 0" N REMOVE AND RELOCATE ALL ELECTRICAL WIRING IN OR ON WALLS BEING REMOVED EXISTING BOOSTER PUMPS FLOOD LIGHTS TO BE REMOVED. REMOVE ALL CONDUIT AND WIRE BACK TO SOURCE. LIGHT SWITCH TO BE REMOVED LIGHTS FIXTURE TO BE REMOVED. REMOVE ALL CONDUIT AND WIRE BACK TO SOURCE. LEGEND SYMBOL DESCRIPTION WORK TO BE REMOVED EXISTING NEW WORK T THERMOSTAT MD MOTORIZED DAMPER EXHAUST FAN #1 UH-1 UNIT HEATER #1 CIRCUIT HOMERUN (120V) TO BOARD CIRCUIT HOMERUN (208V/1Ø) TO BOARD 120/208V 3Ø 4W BOARD GFI GROUND FAULT INTERRUPT S SINGLE-POLE SWITCH # MOTOR, # INDICATES HORSEPOWER 30/- DISCONNECT SWITCH ENCLOSED CIRCUIT BREAKER WP WEATHERPROOF MCB MAIN CIRCUIT BREAKER DUPLEX RECEPTACLE MOTOR STARTER NOTE: ALL WORK IS NEW UNLESS NOTED OTHERWISE. ELECTRICAL DEMOLITION PLAN AND LEGEND E-1

N DUPLEX TRANFER PUMPS UH-1 5 5 LE ULTRASONIC LEVEL SENSOR A A A WELL AND BOOSTER PUMP CONTROL 12"x12" WIREWAY BAG FILTERS 200A CIRCUIT BREAKER EXISTING BOOSTER PUMPS 200A, 120/208V, 3Ø, 4W BOARD CT CABINET AND UTILITY METERING SIX (6) TRAIN ION EXCHANGE FILTRATION SYSTEM. NO ELECTRICAL REQUIREMENTS, ALL INSTRUMENTS BATTERY OPERATED. TVSS 60A ENCLOSED CIRCUIT BREAKER FOR DUPLEX TRANSFER PUMP CONTROL CIA ALARM GFI T GFI EXIT S S 48" AFF 400A, DOUBLE-THROW SWITCH FAN STARTER PORTABLE GENERATOR CONNECTION ENCLOSURE NOTE: PROVIDE QTY. 5, 50' LENGTHS OF PORTABLE GENERATOR CABLE. CABLES SHALL BE COLOR CODED BLACK, RED, BLUE, WHITE AND GREEN (208V, 3Ø, NEUTRAL AND GROUND). CABLE SHALL BE #4/0, TYPE W, 600V, COPPER CABLE RATED 400A, TERMINATED WITH FEMALE AND MALE SERIES 16 CAM-LOCK CONNECTORS. AS MANUFACTURED BY LEX PRODUCTS. B GFI WP NOTES: 1. PROVIDE 2 #12, 1 #12 GND, TYPICAL FOR EACH 120V AND 208V, 1Ø CIRCUIT HOMERUN FROM EQUIPMENT TO BOARD. 2. REUSE EXISTING 20A/1P CIRCUIT BREAKER FOR NEW LIGHTING. 3. PROVIDE 3-20A/1P CIRCUIT BREAKERS FOR AND RECEPTACLE CIRCUITS. 4. PROVIDE 3-20A/2P CIRCUIT BREAKERS FOR UNIT HEATER CIRCUITS. 5. EXTERIOR LIGHTING CIRCUITS ARE SHOWN DIAGRAMATICALLY, ALL CONDUIT AND WIRE SHALL BE RUN INTERNAL TO THE BUILDING. ELECTRICAL INSTALLATION PLAN SCALE: 1" = 1' - 0" LIGHTING FIXTURE SCHEDULE TYPE LAMPS WATTS MOUNTING VOLTAGE FIXTURE MANUFACTURER AND CATALOG NUMBER REMARKS A 39W LED CEILING 120V LITHONIA FEM4 LED LOW-PROFILE AND GASKETED 4,000 LUMENS, 4100 K, FROSTED LENS B 19W LED WALL 120V LITHONIA TWS LED WALL LUMINAIRE 1017 LUMENS, 5000 K, PHOTOCELL, DARK BRONZE LITHONIA OFLR 9 P DUSK-TO-DAWN C 32W LED WALL 120V 2067 LUMENS, PHOTOCELL, BRONZE FLOODLIGHT, 3 ADJUSTABLE HEADS EXIT LITHONIA ECR LED M6 COMBINATION EMERGENCY LIGHTING AND EXIT, 120V, RED LETTERING. E-2 ELECTRICAL INSTALLATION PLAN C UH-3 UH-2 DUPLEX TRANSER PUMP CONTROL C 500 GALLON RECEIVING TANK MD

DUPLEX TRANSFER PUMP SCHEMATIC DIAGRAM TRANSFER PUMPS TAP EXISTING FEEDER FOR DUPLEX TRANSFER PUMP CONTROL. PROVIDE POLARIS INSULATED SPLICE KITS AS REQUIRED. 5 5 3 #10 1 #10 GND ULTRASONIC LEVEL SENSOR (500 GALLON RECEIVING TANK) 4-750 AL + GND 12"x12" WIREWAY 4 #6 1 #10 GND 1"C FACTORY CABLE, 400A 120/208V 3Ø, 4W INCOMING UTILITY SERVICE 400A CT CABINET 400A DOUBLE-THROW SWITCH (MAIN DISCONNECT) 60A/3P UTILITY METER PAN CIA ALARM ALARM MONITORING NOTES: 1. CONTRACTOR TO ENGAGE THE SERVICES OF THE TOWN'S ALARM MONITORING COMPANY TO MODIFY EXISTING ALARM TO ACCEPT NEW INPUTS. 2. CONTACT "CIA" COMMERCIAL INSTRUMENTS & ALARMS, INC. 845-896-9500. M 200A/3P DUPLEX TRANSFER PUMP CONTROL PORTABLE GENERATOR CONNECTION ENCLOSURE WELL AND BOOSTER PUMP CONTROL 14 #14 COMMON ALARM PUMP 1 FAILURE PUMP 2 FAILURE HIGH LEVEL ALARM LOW LEVEL ALARM 4 SPARE #14 PORTABLE GENERATOR NOTE: TOWN OWNED PORTABLE EMERGENCY GENERATOR IS 110KW STANDBY RATED MULTIQUIP MODEL DCA125SSJU4I WHISPERWATT MQ POWER SERIES. 110KW GENERATOR CAPACITY MATCHES 400A, 208V SERVICE SIZE TO CARRY 200A ALL BUILDING LOADS. 120/208V 3Ø, 4W BOARD EXHAUST FAN SCHEMATIC DIAGRAM T THERMOSTAT 2 #14 MD MOTORIZED DAMPER 2 #12 1 #12 GND BOARD NOTES: 1. PROVIDE SIZE 00, 120V ENCLOSED MOTOR STARTER WITH H-O-A SWITCH. 2. PROVIDE OVERLOAD HEATERS, SIZE AS REQUIRED. 3. THERMOSTAT SHALL BE WIRED TO AUTO MODE. 4. PROVIDE HONEYWELL, MODEL T4051B, 120V LINE VOLTAGE THERMOSTAT FOR COOLING APPLICATION. 2 #12 1 #12 GND CAULK ALL AROUND WITH SILICONE SEALANT PRIOR TO INSTALLING BUSHING FLANGED TYPE SEALING BUSHING AS SPECIFIED GROUT OPENING WITH NON-SHRINK GROUT CONDUIT CONCRETE WALL OR FOUNDATION LINK SEAL IS ACCEPTABLE CORE DRILLED HOLE INSTALL O-Z GEDNEY CABLE WATER TIGHT SEALS IN EACH CONDUIT THAT PENETRATES BUILDING WALL TYPICAL SLEEVE DETAIL FOR EXISTING WALL PENETRATION ELECTRICAL DIAGRAMS AND DETAILS E-3

EXISTING UNIT HEATER TO BE REMOVED. TYPICAL FOR 2. MECHANICAL DEMOLITION PLAN SCALE: 1" = 1' - 0" N LEGEND SYMBOL DESCRIPTION WORK TO BE REMOVED EXISTING NEW WORK T THERMOSTAT MD MOTORIZED DAMPER ESP EXTERNAL STATIC PRESSURE DENOTES EXHAUST FAN #1 UH-1 DENOTES UNIT HEATER #1 NOTE: ALL WORK IS NEW UNLESS NOTED OTHERWISE. MECHANICAL DEMOLITION PLAN M-1

16"x16" LOUVER BDD UH-1 SEE DETAIL DRAWING M-3 SEE DETAIL DRAWING M-3 FAN AND LOUVER ASSEMBLY TO BE MOUNTED 90" AFF MECHANICAL INSTALLATION PLAN SCALE: 1" = 1' - 0" N T UH-3 M-2 MECHANICAL INSTALLATION PLAN UH-2 12"x10" LOUVER SEE DETAIL DRAWING M-3 MD

PLYWOOD WALL AND VINYL PLYWOOD WALL AND VINYL 2" X 4" WOOD STUD SUPPORT CONNECTED TO 2" X 6" VERTICAL WOOD BEAMS CAULK ALL AROUND (TYP.) CLIP ANGLE FIXED LOUVER WITH DRAINABLE BLADES ALUMINUM BIRD SCREEN FURNISH WITH LOUVER BIRD SCREEN CAULK ALL AROUND (TYP.) CLIP ANGLE SCREW FASTENER (TYP.) 2" X 4" WOOD STUD SUPPORT CONNECTED TO 2" X 6" VERTICAL WOOD BEAMS PLYWOOD WALL AND VINYL 2" X 4" WOOD STUD SUPPORT CONNECTED TO 2" X 6" VERTICAL WOOD BEAMS LOUVER DETAIL FIXED LOUVER DETAIL UNIT NO. CFM ESP (WG) WEIGHT (LBS) FAN RPM POWER (W) MOTOR HP V/P/Hz EXHAUST FAN SCHEDULE ARRANGEMENT TYPE MFR & MODEL NO. REMARKS 712 0.1 42 1550 0.094 0.05 120/1/60 DIRECT DRIVE PROPELLER COOK 10S15D UNIT HEATER SCHEDULE UNIT NO. kw AMPS ELECTRICAL WEIGHT MFR & MODEL NO. REMARKS UH-1 3 15 208/1/60 27 QMARK MUH0381 UH-2, UH-3 1.5 208/1/60 18.5 QMARK 2548W ELECTRIC UNIT HEATER SUPPORT DETAIL (TYP.) FLOOR SLAB ±7'-0" UNIT HEATER WALL BRACKET ANCHOR TO WALL ±20 1/2" EXTERIOR WALL ROOF FAN COLLAR SUPPORT FROM PLENUM 16 GAUGE S.S. SHEET PLENUM TO EXTEND THROUGH WALL 2"x2"x 4" 1 S.S. ANGLE ALL SIDES PATCH WALL LINTEL 12"x12" ACCESS DOOR (HINGED) FIXED LOUVER MOTOR MOUNTED ON VIBRATION ISOLATOR. WIRE MESH INLET GUARD BACKDRAFT DAMPER 14" MIN. PATCH EXISTING WALL TO MATCH LOUVER AND SLEEVE OPENING SIZE (TYP.) WALL 2"x2"x1/4" S.S. WELDED ANGLE FRAME FOR SUPPORT NOTE: ALL ANGLES AND FASTENERS TO BE 316 S.S. PROPELLER FAN MOUNTING DETAIL DETAILS AND SCHEDULES M-3