Report Number Test Laboratory Name / Address Applicant Name / Address Manufacturing Name / Address Product Brand Name Description Model(s) (if applicable) Model Similarity Ratings Refrigerating Appliance DOE Test Report Date of receipt of sample(s) 18/Jul /2016 20160725A2 No. 2, Block 11, Shunde Hi-Tech Industrial Park, Wusha, Shunde, Guangdong, China Husky Refrigerators Mfg Company limited No. 2, Block 11, Shunde Hi-Tech Industrial Park, Wusha, Shunde, Guangdong, China Same as the applicant. Self-Contained Commercial Refrigerators and Commercial Freezers With Doorst Husky(for model SC-70); Nostalgia(for model BC24COKE) The product covered by this report is a Self-Contained Commercial Freezers With Doorst. SC-70,BC24COKE The models above are identical except for the brand name and model designation. 110V, 60Hz, 1.3A, R600a/0.71oz Date of test 19/Jul /2016-24/Jul /2016 Test standard(s) or criteria(s) Conclusion ANSI/ASHRAE Stand 72-2014; These results are in compliance with DOE Program Requirements for Residential Refrigerators. Date of issue 25/Jul /2016 Prepared by: Approved by: Fan Yang Engineer Fire Xu Assistant Manager This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. The test report only allows to be revised only within the report defined retention period unless standard or regulation was withdrawn or invalid. When determining the test result, measurement uncertainty has been considered. Page 1 of 8 TRF NO.: FRI DOE TRF_V3.0
Nameplate: Page 2 of 8
Product Information: Model of Unit Under Tested Product Condition Serial No. SC-70 Prototype NA Product Type Self-Contained Commercial Refrigerators and Commercial Freezers With Doors Refrigerant Charge of refrigerant (oz) Refrigerating type Condenser type Condenser location Power Supply Built-in appliances R600a 0.71 Compression-type Smooth wall Sides Single Phase No Overall dimensions (mm) Width: 430 Depth: 475 Height: 690 Defrosting type Automatic defrost Critical Components: Name Manufacturer/trademark Compressor Donper Type/model DG40BY1 Technical data 110-120V~, 60Hz, 1PH, R600a Measurement conditions: a) General Test voltage (V): Test Frequency (Hz): 115 60 Air velocity Range (m/s): 0.04 0.16 b) Ambient Temperatures of Energy Consumption Test: Dry Bulb ( C): 24 0.6 Page 3 of 8
Volume Measurement: Compartment Description type Fresh-food compartment Width Depth Heigh Volume Number Volume (L) (mm) (mm) (mm) (Cu.ft) Fresh-food part 1 336 320 502 1 53.98 1.91 Fresh-food part 2 336 231.5 190 1 14.78 0.52 Fresh-food part 3 5 217 248-2 -0.53-0.02 Fresh-food part 4 Total: 68.23 2.41 Compartment type Fresh-food compartment Total volume Total adjusted volume Volume (L) Volume (Cu.ft) 68.23 2.41 68 2.4 68.23 2.41 Page 4 of 8
Energy Consumption Test: Sample No. Location of thermostat setting of the test The average temperature in fresh food compartment, F Energy expended during the test period, kwh Test cycle energy expended during the test cycle, kwh/d Sample 1 4.2 37.5 37.7 1.018 Length of time of the test period, min 1479 0.992 Sample 2 3.9 1.012 1483 0.981 Sample 3 4.3 38.2 1.025 1451 1.018 Total per-cycle energy consumption, kwh/year 362.08 358.07 371.57 Test Result Summary: Sampling size 3 Mean of sample 363.91 Sample standard deviation 6.933 UCL/1.1 341.45 The decided value, kwh/year The decided value, kwh/d 363.91 1.03 The rated energy consumption, kwh/year 376 DOE Maximum energy consumption limit, kwh/year 402 Verdict Pass Page 5 of 8
Temperature measurement in fresh food compartment: Page 6 of 8
Photos: Photo 1 - Front view Photo 2 - Back view Page 7 of 8
Photo 3 - Front view with open door Photo 4 - Label of compressor Page 8 of 8