Refrigerating Appliance DOE Test Report

Similar documents
Refrigerating Appliance ErP Test Report

REPORT NUMBER: MID-003r1 ORIGINAL ISSUE DATE: March 11, 2015 Revised Date: March 20, 2015

RENDERED TO Vipco Industries Inc th Avenue SE Calgary, AB T2C 0B3

TEST REPORT EVALUATION CENTER Intertek Testing Services NA Ltd Brigantine Drive Coquitlam, B.C. V3K 7C1

RENDERED TO. Laminam S.P.A. Via Ghiarola Nuova Fiorano Modenese Italy

TEST REPORT. NFPA 253 / ASTM E648-14c Standard Test Method for Critical Radiant Flux of Floor-Covering Systems Using a Radiant Heat Energy Source

ENGINEERING EVALUATION

RENDERED TO. Radial Engineering Limited 1588 Kebet Way Port Coquitlam, B.C. V3C 5M5

FABRITRAK SYSTEMS, INC. FIRE TEST REPORT

SIGMADEK, LTD. FIRE TEST REPORT

FUNDERMAX GMBH FIRE TEST REPORT

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT NUMBER: SAT-001B ORIGINAL ISSUE DATE: February 29, 2016 REVISED DATE:

Intertek. REPORT NUMBER: SAT-005 ORIGINAL ISSUE DATE: October 29,2008 REVISED DATE: November 19, 2008

Fire Performance of Translucent Systems

Declaration of Conformity

REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045

REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005

REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK 13045

January 26, Mr. Larry Sunshine Bentax USA 418 Meadow Street Fairfield CT Dear Mr. Sunshine:

REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005

K-SQ13, KA-SQ13, K-SQ14, KA-SQ14, KO-SQ13, KOA-SQ13, KO-SQ14, KOA-SQ14, K-SQ13C, KA-SQ13C, K-SQ14C, KA- SQ14C, KO-SQ13C, KOA-SQ13C, KO-SQ14C,

REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005

FORM ACCL-PC1 ACCL WITNESS TEST PROCEDURE AND CHECKLIST

Test Report No.: Page 2 of 14

Upright freezer V 60Hz ccl 4. Block condenser Aspera compressor grp. 38. Upright freezer compr. grp 38. Version: Date: Initials: Description:

CLASSIFICATION Constructional Data Report (CDR)

FLASHLIGHT ANSI STANDARDS

Refrigerator and Air conditioner Testing in the Republic of Korea

Report No.: SQE Page 2 of 11 Issued: Test Report No. : EMC -- T E S T R E P O R T SQE Equipment under Test : 24Bit Barometer

SMALL MOTOR CONTROLLERS

REPORT Dialight, 1501 Route 34 South, Farmingdale, NJ 07727

PRODUCT PERFORMANCE TEST REPORT. Report No.: D Test Date: May 29, Rendered to: Natural Light Energy Systems Phoenix, Arizona

1.0 INTRODUCTION 2.0 CLASSIFICATION CRITERIA

PQS Independent type-testing protocol

STANDARDS UPDATE NOTICE (SUN) ISSUED: August 23, 2017

Instruction Manual Refrigerated Counter Top Displays

Evaporative Cooling in a Hot-Dry Climate

TEST REPORT IEC Safety of household and similar electrical appliances Part 2: Particular requirements for massage appliance

4.5 CU.FT. REFRIGERATOR INSTRUCTION MANUAL

ARS2304A PARS2304AB0 ARS2604A PARS2604AB0 ARS2304A PARS2304AC0 ARS2604A PARS2604AC0 ARS2304A PARS2304AW0 ARS2604A PARS2604AW0 !

Transcritical CO2 Bottle Cooler Development

TEST REPORT IEC Safety of laser products - Part 1: Equipment classification and requirements

TITLE: Ice-lined Refrigerator or Combined Refrigerator-Icepack Freezer, Compression Specification reference:

Glass Door Merchandisers GDC10, GDC12F, GDC15, GDC23, GDC24F, GDC40, GDC40F, GDS47, GDC69

1.7 CU.FT. REFRIGERATOR INSTRUCTION MANUAL MCBR170BMD

Food Service Technology Center

Repair Parts List REFRIGERATOR MODEL NUMBER LTF2112ARB. When requesting service or ordering parts, always provide the following information:

Listing Constructional Data Report (CDR)

2.4 Cu. Ft. Compact Refrigerator

EHPA Testing Regulation

AUDITORY SYSTEMS LABORATORY HEARING PROTECTION DEVICE ATTENUATION TEST REPORT

APPROVAL SHEET SPECIFICATIONS OF HERMETIC SCROLL COMPRESSOR C-SBR180H16A

WHITE PAPER. ANSI/AHRI Standard for Fan and Coil Evaporators - Benefits and Costs

InstructIon Manual KrEs EQuIPMEnt stands

MODEL RD-8 Self Contained MODEL RD-2

Drink Showcase Equipped with Inverter Freezer

FROST FREE REFRIGERATOR INSTRUCTION MANUAL

HERO SERIES-DC INVERTER HEAT PUMPS

MEASUREMENT AND TEST REPORT

Procedure for the Approval of New Fire Detection and Alarm Technologies

Channel Safety Systems Limited Unit 9, Petersfield Business Park Bedford Road Petersfield GU32 3QA UK. Authority & date SMO /04/2014

ENERGY EFFICIENCY STANDARD AND LABELING FOR REFRIGERATOR IN INDONESIA

PERFORMANCE TEST REPORT. Rendered to: EVERBLOCK SYSTEMS, LLC. PRODUCT: Modular Block Product

Ingersoll Rand. Refrigerated Air Dryers

CAUTION. All safety information must be followed as provided in Service Manual RS ! WARNING

REPAIR PARTS LIST REFRIGERATOR. Model No.(s) (White) (Stainless Steel) (Silver on Black) 106.

FRENCH DOOR & BOTTOM MOUNT Date and Place

Vibration tests on a TNAML Luminaire

Food Service Technology Center

Outdated Publication, for historical use. CAUTION: Recommendations in this publication may be obsolete. Family Community Education.

Test Report. Appliance EMF Testing

MANUAL. Instructions for installation use & general maintenance of your HORIZONTAL FREEZER HFF, FLORENCIA and MILAN Product Lines MAN-017-R

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Ice Cream Freezers

to give you service for many years. CHEST FREEZER CFA1300W PERFORMANCE

General Features. 01. CoolSmart Controller Professional Refrigeration Upright Cabinet Series

User Manual. Commercial Refrigerator And Freezer User s Manual

PR / MP I Laboratory / Medicine

The test items passed the test specification(s).

NVLAP LAB CODE ISTMT Test Report. For IROCO AOTOM (HUBEI) PHOTOELECTRICITY CO., LTD

PREMIUM STAINLESS STEEL UNDER SINK WATER CHILLER

Standards Update Notice (SUN) Issued: January 9, 2017

RPI Industries, Inc.

RPI Industries, Inc.

Engineering Report Vibration Test for Intertek Testing Services Prepared by Approved by 9725 Girard Avenue South Minneapolis, MN 55431

Standards Update Notice (SUN) Issued: February 2, 2017

EN50438 TEST REPORT SUMMARY. Requirements for the connection of micro-generators in parallel with public low-voltage distribution networks

Model No. GB-PAC-08E4. 8,000 BTU Portable Air Conditioner Operating Instructions

Instruction Manual. 4.6 Cu. Ft. Refrigerator/Freezer. Wards.com Wards.com The solution for your cold-storage needs!

Product Information and Technical Guide

TEST REPORT. Report No.: E Test Date: May 6, Rendered to: FUNDERMAX GMBH A-9300 St. Veit an der Glan, Austria

GLIDER_. air cooled liquid chilled chillers / heat pumps

Impact of Manual Defrost vs. Auto Defrost Freezers on Sample Temperature

QATAR STANDARD QS SASO 2692/201 QS SASO 2692 ENERGY LABELLING REQUIREMENTS OF HOUSEHOLD ELECTRICAL CLOTHES WASHING MACHINES


Transcription:

Report Number Test Laboratory Name / Address Applicant Name / Address Manufacturing Name / Address Product Brand Name Description Model(s) (if applicable) Model Similarity Ratings Refrigerating Appliance DOE Test Report Date of receipt of sample(s) 18/Jul /2016 20160725A2 No. 2, Block 11, Shunde Hi-Tech Industrial Park, Wusha, Shunde, Guangdong, China Husky Refrigerators Mfg Company limited No. 2, Block 11, Shunde Hi-Tech Industrial Park, Wusha, Shunde, Guangdong, China Same as the applicant. Self-Contained Commercial Refrigerators and Commercial Freezers With Doorst Husky(for model SC-70); Nostalgia(for model BC24COKE) The product covered by this report is a Self-Contained Commercial Freezers With Doorst. SC-70,BC24COKE The models above are identical except for the brand name and model designation. 110V, 60Hz, 1.3A, R600a/0.71oz Date of test 19/Jul /2016-24/Jul /2016 Test standard(s) or criteria(s) Conclusion ANSI/ASHRAE Stand 72-2014; These results are in compliance with DOE Program Requirements for Residential Refrigerators. Date of issue 25/Jul /2016 Prepared by: Approved by: Fan Yang Engineer Fire Xu Assistant Manager This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. The test report only allows to be revised only within the report defined retention period unless standard or regulation was withdrawn or invalid. When determining the test result, measurement uncertainty has been considered. Page 1 of 8 TRF NO.: FRI DOE TRF_V3.0

Nameplate: Page 2 of 8

Product Information: Model of Unit Under Tested Product Condition Serial No. SC-70 Prototype NA Product Type Self-Contained Commercial Refrigerators and Commercial Freezers With Doors Refrigerant Charge of refrigerant (oz) Refrigerating type Condenser type Condenser location Power Supply Built-in appliances R600a 0.71 Compression-type Smooth wall Sides Single Phase No Overall dimensions (mm) Width: 430 Depth: 475 Height: 690 Defrosting type Automatic defrost Critical Components: Name Manufacturer/trademark Compressor Donper Type/model DG40BY1 Technical data 110-120V~, 60Hz, 1PH, R600a Measurement conditions: a) General Test voltage (V): Test Frequency (Hz): 115 60 Air velocity Range (m/s): 0.04 0.16 b) Ambient Temperatures of Energy Consumption Test: Dry Bulb ( C): 24 0.6 Page 3 of 8

Volume Measurement: Compartment Description type Fresh-food compartment Width Depth Heigh Volume Number Volume (L) (mm) (mm) (mm) (Cu.ft) Fresh-food part 1 336 320 502 1 53.98 1.91 Fresh-food part 2 336 231.5 190 1 14.78 0.52 Fresh-food part 3 5 217 248-2 -0.53-0.02 Fresh-food part 4 Total: 68.23 2.41 Compartment type Fresh-food compartment Total volume Total adjusted volume Volume (L) Volume (Cu.ft) 68.23 2.41 68 2.4 68.23 2.41 Page 4 of 8

Energy Consumption Test: Sample No. Location of thermostat setting of the test The average temperature in fresh food compartment, F Energy expended during the test period, kwh Test cycle energy expended during the test cycle, kwh/d Sample 1 4.2 37.5 37.7 1.018 Length of time of the test period, min 1479 0.992 Sample 2 3.9 1.012 1483 0.981 Sample 3 4.3 38.2 1.025 1451 1.018 Total per-cycle energy consumption, kwh/year 362.08 358.07 371.57 Test Result Summary: Sampling size 3 Mean of sample 363.91 Sample standard deviation 6.933 UCL/1.1 341.45 The decided value, kwh/year The decided value, kwh/d 363.91 1.03 The rated energy consumption, kwh/year 376 DOE Maximum energy consumption limit, kwh/year 402 Verdict Pass Page 5 of 8

Temperature measurement in fresh food compartment: Page 6 of 8

Photos: Photo 1 - Front view Photo 2 - Back view Page 7 of 8

Photo 3 - Front view with open door Photo 4 - Label of compressor Page 8 of 8