Type FK-EU FOR DIVERSE APPLICATIONS. Homepage > Prodotti > Protezione dal fuoco e dal fumo > Serranda tagliafuoco > Type FK-EU

Similar documents
Type FK-EU FOR DIVERSE APPLICATIONS. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FK-EU

Fire dampers. For diverse applications

Type FKS-EU COMPACT DIMENSIONS, IDEAL FOR RESTRICTED SPACES. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FKS-EU

Type FKRS-EU COMPACT DIMENSIONS, IDEAL FOR RESTRICTED SPACES. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FKRS-EU

Homepage > Prodotti > Sistemi di ventilazione decentralizzata > Dispositivi verticali > Type FSL-V-ZUS. Type FSL-V-ZUS

Kezdőlap > Termékek > Tűz és füst elleni védelem > Füstmentesítő csappantyúk > Típus EK-EU. Típus EK-EU

Type EK-EU FOR MECHANICAL SMOKE EXTRACT SYSTEMS AND AS AN ADDITIONAL SUPPLY AIR INLET, ALSO FOR NATURAL SMOKE AND HEAT EXHAUST SYSTEMS

K*, R* Ventilation grilles

Type RM-O-3-D. Duct smoke detector used to prevent smoke from spreading through the ducts of ventilation and air conditioning systems

Type VDW WITH LOW SOUND POWER LEVEL FOR COMFORT ZONES, WITH INDIVIDUALLY MANUALLY ADJUSTABLE AIR CONTROL BLADES

Type TDF-SilentAIR WITH VERY LOW SOUND POWER LEVEL FOR COMFORT ZONES, WITH FIXED AIR CONTROL BLADES

Dual certification! Air handling units for potentially explosive atmospheres

Homepage > Products > Grilles and Diffusers > Ceiling diffusers > Design ceiling swirl diffusers > Type ADD. Type ADD

Fire damper ETPR Instructions for Installation, Operation and Maintenance 10/2016

Ceiling diffusers. Type DLQL

Homepage > Products > Control systems > Demand-based room control with X-AIRCONTROL > Sensors > X-SENS X-SENS

Type PWX HORIZONTAL CHASSIS TYPE WATERSIDE FANCOILS FOR CONCEALED OR EXPOSED INSTALLATIONS

SECTION AIR DUCT ACCESSORIES

Homepage > Products > Decentralised ventilation Systems > Vertical devices > Type FSL-V-ZUS. Type FSL-V-ZUS

Ceiling swirl diffusers

Ceiling swirl diffusers

Life Safety Dampers Selection and Application Manual

Homepage > Products > Decentralised ventilation systems > Vertical units > Type FSL-V-ZAB/SEK FSL-V-ZAB/SEK

AIR DISTRIBUTION. C. Section Building Automation and Control System Guidelines. D. Section Fire Alarm System & Detection Systems

ECOSMART TWINFANS. (EST-X/R/B) 1 phase, Direct Drive, Run & Standby For External, Roof Mounted and Internal use Installation and Maintenance

Compact. Efficient. TROX.

Square Ceiling Diffusers : All extruded aluminum constructions. Opposed blade damper is adjustable from face of diffuser. Available in square and

ECOSMART XTRACTOR. (ESX-X/R/B) 1 phase, Direct Drive For External, Roof Mounted and Internal use Installation and Maintenance.

Passive chilled beams

- SAFETY MANUAL - DAMPERS

Premium Efficiency Heat Recovery Unit. D-AHU Modular L. Air Handling Units

ECOSMART TWINFANS. (EST) 1 phase, Direct Drive, Run & Standby Fans for indoor use. Installation and Maintenance

Decentralised ventilation units

FIRE & SMOKE DAMPERS. Meeting tomorrow's requirements for fire and smoke protection today.

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

Advanced Air. Hard Wired Damper Control Panels. Systems 10, 11, & 12. Hard-Wired Systems. Bespoke Systems Available. Value Engineered Solutions

Units for suspended ceilings

Smoke Control Ducts and Dampers For Single Compartment Applications. Fulfilling new requirements for EN product standards for CE Marking

AIR HANDLING UNITS MANDÍK

Air distribution for clean rooms. Clever and flexible.

BSK-RPR Fire Damper. Additional operating instructions according to

TEKNISK DOKUMENTATION VENTILATION BG BURCHARTH A/S

ESAR SMOKE CONTROL DAMPER» TECHNICAL CATALOGUE

FEATURES AND BENEFITS

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise VAV Terminal Units Full Spec. Prepared by: Phone Number: Prepared for:

SINGLE PHASE RANGE BD BD 19/19 M4 1/5 BD 19/19 M6 1

A. General: Refer to paragraph entitled "SUBMITTAL" in Section Include the following data:

Intumescent Fire Dampers

Chilled Ceiling Elements

BKA-EN Fire Damper. Additional operating instructions according to

Decentralised ventilation

Fire protection unit

FUME EXTRACT STRATEGY STATEMENT

Compact. Efficient. TROX.

INSTALLATION AM ; AMC

Gas-Fired Indoor and Outdoor Duct Furnaces

SERIES FAN VAV TERMINAL BOXES TYPE CVFB & SFTB

Able to respond to smoke alarms for the protection of escape routes and areas with sleeping risk (ADB)

Units for suspended cei lings

DUCT SYSTEMS CHAPTER 6

VL120. Multi blade smoke evacuation damper 120' C-NT-V24-A 01/2016

Smoke extraction duct of sheet steel

Natural Ventilation. e-stack A-Series Ventilation System for Buildings with Atria. Installation and Maintenance. Palletised

Air distribution systems. Rectangular displacement outlet VA-RN... with adjustment device VA-RV...

DACC Health Sciences Building Air Handler Assessment/Study

DUCT SMOKE DETECTORS IQ8

INDOOR USE ONLY. Installation and Maintenance XTRACTOR. (ESX) 1 and 3 phase, Direct Drive, Fans for indoor use

NTD-125-*, NTD-204-* & NTD-220-* Nuaire Round & Rectangular Thermal Ducting Installation Guide

DUCT SYSTEMS CHAPTER 6

Part # Page Dampers Supported Directly From Structure 5. Dampers Supported From Ductwork Above 4

290 on. 286 on. Comfortable climate with pre-heated, filtered supply air. Fresh air boxes ALB WW MODEL WITH WARM WATER HEATING

TEVHR. Heat Recovery Ventilator

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

TUNNEL FANS STANDARD AND HOT SMOKE

Fire, Smoke, and Combination Fire Smoke Dampers

FIRE RATED PRODUCTS GENERAL PRODUCT OVERVIEW. Fire Rated Products

WHHR Midi & Midi Lite

Manual Power relay SR853

RAS Kp AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 LIQUID CHILLERS - AIR COOLED AIR

Easy installation in both new construction and retrofit. READ AND SAVE THESE INSTRUCTIONS Installer: leave this guide with homeowner.

SUNWARM AIR SOLAR PRE-HEAT VENTILATION SYSTEM

The power of ventilation

INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL

HIGH EFFICIENCY POOL DEHUMIDIFIER AND CONDITIONER WITH HIGH HEAT RECOVERY RATES. Air treatment unit. Swimming pool waste air 28 C-65%

Installation and Maintenance

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

Cabinet Unit Heaters Steam / Hot Water

NON ELECTRICAL EQUIPMENT IN HAZARDOUS AREAS

Installation and Maintenance

FSD-TD Series. Fire and Smoke Dampers B RITAI N. LPCB certificated fire dampers (LPS 1162)

Installation and Maintenance

Circular Fire Damper Cartridge

IFE Level 3 Certificate in Passive Fire Protection

Advance Release September 2009

PDH & Professional Training

IFE Level 3 Certificate in Passive Fire Protection

Airflex Radial & ISO Thermal pipe

Easy installation. EZ80N EZ Fit Ventilation Fan INSTALLATION GUIDE READ AND SAVE THESE INSTRUCTIONS. Table of Contents

FIRE PROTECTION FIRE DAMPERS ISONE+

XB-EFA-8L-BK & XB-EFA-8R-BK

Transcription:

Type FK-EU FOR DIVERSE APPLICATIONS Rectangular fire damper for the isolation of duct penetrations between fire compartments, for a variety of installation situations, available in many different sizes and constructions Nominal sizes 200 200 1500 800 mm, in increments of 1 mm Low differential pressure and sound power level Explosion-proof construction (ATEX) as an option Can also be used as an air transfer damper Optional stainless steel casing or powder-coated casing for increased corrosion protection Integration into the central BMS with TROXNETCOM Universal installation options Optional equipment and accessories Electric actuator 24 V/230 V Release temperature 72/95 C Duct smoke detector RM-O-3-D

Application TROX fire dampers of Type FK-EU, with CE marking and declaration of performance, for the isolation of duct penetrations between fire compartments in the event of a fire To prevent the propagation of fire and smoke through ductwork to adjacent designated fire compartments Special characteristics Declaration of performance according to Construction Products Regulation Classification to EN 13501-3, up to EI 180 (v e, h o, i o) S Building inspectorate licence Z-56.4212-991 for fire resistance properties Complies with the requirements of EN 15650 Tested to EN 1366-2 for fire resistance properties Hygiene complies with VDI 6022 part 1 (07/2011), VDI 3803 (10/2002), DIN 1946 part 4 (12/2008), and EN 13779 (09/2007) Corrosion protection according to EN 15650 in connection with EN 60068-2-52 Closed blade air leakage to EN 1751, class 2 Casing air leakage to EN 1751, class C; (B + H) 700, class B Low differential pressure and sound power level Any airflow direction Integration into the central BMS with TROXNETCOM Classification Class of performance to EN 13501-3, up to EI 180 (v, h, i o) S e o Nominal sizes B H: 200 200 1500 800 mm (in increments of 1 mm)) L: 375 mm or 500 mm Variants With fusible link With fusible link for use in potentially explosive atmospheres With spring return actuator With spring return actuator for use in potentially explosive atmospheres With spring return actuator and duct smoke detector With spring return actuator, duct smoke detector and cover grilles on both ends for use as an air transfer opening, with general building inspectorate licence Z-6.50-2031 Parts and characteristics Fire dampers with casing length L = 500 mm only for installation: with installation subframe and installation kit; with installation kit for lightweight partition walls; adjacent to solid walls and remote from solid walls Release temperature 72 C or 95 C (for use in warm air ventilation systems) Single-handed operation

Attachments Limit switch for damper blade position indication Limit switch for damper blade position indication for use in potentially explosive atmospheres Spring return actuator for 24 V AC/DC or 230 V AC supply voltage Spring return actuator for 24 230 V supply voltage, for use in potentially explosive atmospheres Network module for the integration with AS-i or LON networks Spring return actuator and pre-wired duct smoke detector, 24 V or 230 V supply voltage Accessories Installation subframe and installation kit for dry mortarless installation in solid walls Installation kit for installation into solid non-load-bearing walls with flexible ceiling joint Installation kit for dry mortarless installation on the face of solid walls Installation kit for dry mortarless installation adjacent to solid walls Installation kit for dry mortarless installation remote from solid walls and ceiling slabs Installation kit for dry mortarless installation in lightweight partition walls/fire walls with metal support structure and cladding on both sides Installation kit for dry mortarless installation into shaft walls with or without metal support structure but with cladding on one side Installation kit for installation into lightweight partition walls with flexible ceiling joint Flexible connectors Cover grille Circular spigots Useful additions Duct smoke detector RM-O-3-D Duct smoke detector with airflow monitor RM-O-VS-D Construction features Rectangular or square construction, rigid casing, both flanges with fixing holes Suitable for the connection of ducts, spigots, flexible connectors or a cover grille The release mechanism is accessible and can be tested from the outside Two inspection access panels Remote control with spring return actuator Materials and surfaces Casing: Galvanised sheet steel Galvanised sheet steel, powder-coated RAL 7001 Stainless steel 1.4301

Damper blade: Special insulation material Special insulation material with coating Other components: Damper blade shafts and driving linkage made of stainless steel Brass or stainless steel bearings Seals of polyurethane or elastomer The construction variants with stainless steel or powder-coated casing meet even more critical requirements for corrosion protection. Detailed listing on request. Standards and guidelines Construction Products Regulation EN 15650:2010 Ventilation for buildings Fire dampers EN 1366-2:1999 Fire resistance tests for service installations Fire dampers EN 13501-3:2010 Fire classification of construction products and building elements EN 1751:1999 Ventilation for buildings Air terminal devices Maintenance The functional reliability of the fire damper must be tested at least every six months; this has to be arranged by the owner of the ventilation system; functional tests must be carried out in compliance with the basic maintenance principles stated in EN 13306 and DIN 31051. If two consecutive tests, one 6 months after the other, are successful, the next test can be conducted one year later. A functional test involves closing the damper blade and opening it again; with a spring return actuator this can be done via remote control Fire dampers must be included in the regular cleaning schedule of the ventilation system. For details on maintenance and inspection refer to the installation and operating manual

TROX Italia Online-Services Service-Hotlines TROX Academy Your contact partner Telefono +39 02-98 29 74.1 Telefax +39 02-98 29 74 60 Online fault report Società unipersonale soggetta a direzione e coordinamento di TROX GmbH Sede legale: Via Mecenate 90-20138 Milano Cap. Soc. EUR 2.000.000 R.E.A. n. 659693 Reg. Impr. MI, C.F. e P.IVA IT 00897380150 Casella di posta certificata: trox@pec.it