Med Touch Master Alarm

Similar documents
Tri-Tech Medical Inc.

Tri-Tech Medical Inc.

Med Touch Combination Alarm Conversion Kits

EZT Series Integra Med Touch Area Alarm & Zone Valve Box with EZ Backfeed

Installation & Operating Instructions for Med Touch Series Area, Master & Combination Alarm Systems

Installation & Operating Instructions for ZT and EZT Integra Touch Series Area Alarm Zone Valve Box Systems

Integra Med Touch Series LCD Area Alarm & Zone Valve Box Systems

DC Series Area, Master and Combination Alarm Systems Opreator s Manual

T a b l e o f C o n t e n t s

Wilo CO-Helix Booster Systems. Product Presentation July, 2017

Alarm module for leak detection with webserver

Across-the-Line SERIES MP300 Combined Manual and Automatic

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

Installation & Operating Instructions for Area, Master & Combination Alarm Systems

Installation, Operation, and Maintenance Instructions

The EN54 Part 2 & 4 Fire System

Laboratory Enclosed Scroll Air Compressor System with Premium NFPA Controls

Variable Frequency Drive SERIES MP800 VFD

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm

Fire control panel detect 3004 plus and accessories

FTA550 JOCKEY PUMP CONTROLLERS

User Manual. Dryer Controller M720

Soft Start Series MP700 Solid State, Reduced Voltage

OJD ITB No Attachment E Duress Alarm Equipment Specifications

Integrated Security Solutions

DIESEL Engine Fire Pump Controllers Features. FD120 Diesel Engine Controllers

Tri-Tech Medical Inc.

FTA550F JOCKEY PUMP CONTROLLERS STANDARD SUBMITTAL PACKAGE

SCAN200E USER S MANUAL

Alert-3 LCD Alarm v2.0

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

Dryer Controller M720

1.1 Remote Annunciator Controller (RAC) using the one ATC-300+ connected via RS-485 network.

Halton SAFE / 7.14 user guide and installation instructions

CSP-204 CSP-208 CSP-104 CSP-108

1.1 Remote Annunciator Controller (RAC) and 1 Switch (ATC-600/800) via Modbus TCP/IP Ethernet Gateway

RPM1600 Series Room Pressure Monitors

Installation Instructions for Med-Touch Series LCD Medical Gas Area, Master & Combination Alarms Conversion Kits

D8024, D9024, D10024 Analog Fire Alarm Control Panels Programming Guide

Laptop / PC Programming Manual

Power Flame Incorporated

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description

CAREL heatersteam Electric Element Steam Humidifiers

Ion Gateway Cellular Gateway and Wireless Sensors

EasyTronic III MANUAL SERVICE

NU2 Smart Power Supply (SPS) Manual

opti-visor ultra-efficient chiller plant automation Typical specification

1.1 Ethernet Remote Annunciator Controller (RAC) using the up to 4 ATC-300+ connected via RS-485 to TCP/IP gateway

DIESEL Engine Fire Pump Controllers Features

Carbon Monoxide Transmitter

SmarTemp Control fx 2.0

LC150 VIEW-AT-A-GLANCE PUMP CONTROL-TELEMETRY UNIT

ModBus DE-1 INSTALLATION AND USER MANUAL

ACTIVE INFRARED BARRIER

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description

Watchguard WGAP864 User Manual

STEAMPAK Series BurnerPAK BMS Burner Management Systems

Centro-Matic Automated Lubrication Systems System Controls

DCA4. Digitally controlled Audio Matrix. Current Thinking. Product Specification March Document Number DDC DCA ACS

DIESEL Engine Fire Pump Controllers Features

Air Comfort. Installation instructions (English) A

APPLICATION DATA SHEET

For Complete Fire and Gas Solutions

Integrated Security Solutions

B and G Series Integrated Security Solution

THX-DL Data Logger USER & INSTALLATION MANUAL V

Dräger Polytron 7000 Fixed gas detector

Series. NX-4-EUR Control Panel. Installation manual

WITH POWER TRANSFER SWITCH STANDARD SUBMITTAL PACKAGE

Fire Alarm Control Panels FPD-7024

PROTECTION CABINETS SUPERVISION CABINETS FOR AUTOMATIC EXTERNAL DEFIBRILLATORS (AEDs)

HALT & HASS Systems.

MEGA. cal electronic gas alarm. Installation, Operation, and Maintenance Instructions. Part No Rev. D Pg.

Master devices. Type X-AIR-ZMAS. Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems

Advanced FireAlarm Panel 1-4Loop

NexSysLink. 2 CAN Display Operation Manual. CAN Instruments Product Family

IntesisBox BACnet/IP Server - Notifier ID3000 series

The EN54 Part 2, 4 and 13 Fire System

Control/Communicator Installation Manual

Stability Chambers & Rooms

The LC-100 s valved manifold controls the flow of air and allows the LC-100 to accurately monitor liquid levels with a minimal air usage.

CSI Master Format 2004 Guide Specification for: Freezer Frost Heave Prevention (Mineral Insulated)

Control Panel. 1.0 GENERAL SCOPE OF WORK Introduction... 2

Manual# User s Manual. DCU 410/408 Engine Control Unit RP 410 Remote Panel FW 2.3

SECTION NURSE CALL SYSTEM

FMR Installation Instructions. Addressable Fire System Controller

Danfoss gas detection units

ONYXWORKS AND FIRSTVISION. Version 4

Advantium 16 System Monitor

HOME AUTOMATION, INC. Lumina and Lumina Pro Lighting and Automation System. Quick-Start Installation Guide

Flopurge TS. Operation Manual

Process Alarm Solutions

Flair 500 Series Annunciators

Trident User s Manual

AUTOMATION. Operator s Manual RST Series Web Enabled Input Module. Rev. A2, 1/12

ThermoControl 0 C - 10 C - 20 C - 30 C

Y-Plant Alert. Alarm Annunciator and Sequence of Event Recording System. BU 04M01A02-01E-A

WATER HEATER ELECTRONIC CONTROLLER USER MANUAL

G SERIES: Security INTEGRATION as you want it. Greater expansion, communication, video integration, system resilience, and automation.

Protégé EliteSuite Eclipse LED Keypad Installation Manual ELT-KLES

Transcription:

Submittal Data Sheet Features The Powerex Med Touch Master Alarm Panel monitors and displays normal and alarm conditions from up to 128 remote medical gas source signals and provides alarm conditions as required by the latest edition of NFPA 99. The alarm is ETL listed to UL 1069 and CSA C22.2 # 205 Signal equipment.* Pressure switches, transducers and DISS union check valve connectors are sold separately. 2.85 LCD touch screen displays up to 8 normal and alarm conditions for pressure switch sensor inputs 2.85 LCD touch screen displays up to 8 normal and alarm conditions and provides a digital pressure display for up to 4 transducer sensor inputs 2.85 LCD touch screen displays normal and high/low alarm conditions for one 4 20 ma sensor input The LCD touch screen allows all alarm programming and set up to be done without the use of tools A green normal or red alarm condition for each gas service confirms the condition for each individual gas service Emergency preparedness instructions - Med Touch Alarm Panels allow users to set up customized instructions for each alarm signal which appear on the screen when the signal is in alarm Up to 128 remote master signals in a single panel Up to 4 master boards (32 signals) in a two slot, 8 (64 signals) in a three and 16 (128 signals) in a five slot panel Wireless (minimal low voltage wiring) models available Last event history (per gas board /signal point) Made in the U.S.A. NFPA and ISO pre-loaded gas labels English, and English/French pre-loaded languages Editable text and alarm labels Self-contained unit - Designed for ease of installation and service Self-diagnostic error message display for ease of maintenance Audio and visual alarm indicators Bright easy to read LCD displays clearly visible in both day and night lighting conditions Constant display and monitoring of each sensor input User programmable high/low set points on transducer and 4-20 ma sensor input boards Dry contacts provided on the CPU module for general fault condition covering entire panel Hinged frame for easy accessibility Color coded displays Five year parts warranty and one year labor warranty. Additional features: Individual user programmable remote signal alarm points to accept NO or NC signals, or may be disabled. Factory preset to accept Normally Closed signals LCD indicators (Green) confirms normal status, (Red) indicates abnormal condition Menu of NFPA 99 master alarm signals for quick, easy selection Gas specific transducer master signal boards. An error message will be displayed if incorrect sensor or no sensor is attached Transducer master signal boards shall be capable of displaying gas readouts in PSI, kpa, BAR, inhg or mmhg Alarm repeat feature is factory set at 10 minutes, and is adjustable or may be turned off. Specifications The alarm shall be the Powerex Med Touch Master Alarm. The panel shall be microprocessor controlled and designed to comply with NFPA 99. The panel shall incorporate 2.85 LCD touch screen display(s) for groups of up to 8 signal points which shall allow all alarm programming and set up to be done without the use of tools. The unit shall be designed to accept an electrical input range of 120-240 volts AC 50-60 hertz. The source voltage shall be stepped down with a self-contained transformer. The panel shall contain audible and visual alarm indicators. The audible alarm may be silenced by pressing the alarm silence button, but the visual alarm indicator can only be cancelled by fault correction. The alarm shall detect and filter out transient (less than 0.6 seconds) signals created by R.F.I. The alarm shall be capable of displaying alarm history for all possible alarm conditions. A security pin code shall be required and must be entered in order to access the programming software. Page 1 of 5

The following options shall be able to be added to the panel at the time of order or after installation; Optional Text / e mail notification of alarm events sent to up to 5 addresses. Optional Ethernet module. This module may be added to any alarm panel. It will provide the following features: Webserver allows a remote user access to the alarm s webpage viewing a graphic image of the alarm with all signal conditions, pressure & event / history log information. Text notification of alarm conditions (up to 5 addresses). Modbus and BACnet gateway interface. Event / history log maintains a rolling list of the 100 most recent alarm condition events and a file of the 1,000 most recent alarm events and is downloadable through embedded web pages. Optional Ethernet connectivity with embedded web page. Interface with building automation system via Ethernet. Wireless (minimal low voltage wiring) models available. Master/Remote Signal Display Dry Contact Sensors Shown in alarm condition displaying emergency instructions. Display blinks on and off when in alarm condition drawing attention and alternates displaying signal identification with user programmed emergency instructions. Dry Contact & Transducer Sensors Shown in normal condition. User selects signal labels from database of NFPA signals included in the boards memory. Individual signal points are pre-programmed NC but may be re-programmed as Disabled or NO by user. Dry Contact Sensors Shown in alarm condition. Display blinks on and off when in alarm condition drawing attention and alternates displaying signal identification with user programmed emergency instructions. Transducer Sensors Shown in alarm condition. The standard display looks and acts the same as both of the above Master/Remote displays. By touching the signal point you wish to view, the display changes to the view shown here providing the additional actual line pressure of the gas being monitored. This may be viewed at any time, in Normal or Alarm condition. Page 2 of 5

Ordering Information Easy to use modular ordering system. Fill in the blanks to specify the Med Touch Master Alarm that meets your needs. Model Numbering: Signal Number Group 001 008 009 016 017 024 025 032 033 040 041 048 PX- T N C S S S S S S S S S S S S S S S S 049 056 057 064 065 072 073 080 081 088 089 096 097 104 105 112 113 120 121 128 Non-Latching Alarm Relays M = 4-20mA P = Dry Contact (8 Signal Points) Q = Transducer (4 Gases, 8 Signal Points) Latching Alarm Relays % = 4-20mA + = Dry Contact (8 Signal Points) # = Transducer (4 Gases, 8 Signal Points) B Blank Slot 4 Vertical Future Expansion (Blank) Positions in One Slot F Future Expansion (Blank) Position List Signal Input Type Choices from Left to Right Starting at Signal Number Group 001 through 008 C = Gas Set 2 Slot Front 3 Slot Front S = Master Signal Input Type 5 Slot Front NOTE: A 35-3032 kit may be ordered separately and installed in the field to provide; Ethernet webserver, event log, alarm notifications may be sent up to 5 users via text or e-mail and Modbus Interface. The 35-3033 Ethernet programming kit is required and must be ordered when the 35-3032 kit is ordered. Only one is needed per facility. NOTE: A 35-3035 kit may be ordered separately and installed in the field to provide a BACnet interface. The 35-3032 and 35-3033 kits are also required whenever the 35-3035 kits is ordered. Only one 35-3033 kit is needed per facility. U Powerex Labeled NFPA Color Code English I Powerex Labeled ISO Color Code English/French N = Number of Slots on Front Panel 2 2 Slot Front Panel 3 3 Slot Front Panel 5 5 Slot Front Panel T = Type of Alarm T Touch Screen Digital Page 3 of 5

Part Number Examples PX-T2UPPPP = 2 Slot Master Alarm Powerex labeled, set for NFPA Color Code English. 32 Dry Contact Signal Points w/ Non-Latching Alarm Relays. No Interface Communication Option. PX-T3I+++FB = 3 Slot Master Alarm Powerex labeled, set for ISO Color Code English/ French gas set. 24 Dry Contact Signal Points w/ Latching Alarm Relays and one Future Expansion (Blank) position at bottom of 2nd slot, 3rd slot Blank. No Interface Communication Option. PX-T5UPPPPPPPPQQQQB3 = 5 Slot Master Alarm Powerex labeled, set for NFPA Color Code English gas set. 64 Dry Contact Signal Points w/ Non- Latching Alarm Relays and 32 Transducer Signal Points W/ Non-Latching Alarm Relays, 5th slot is Blank. Ethernet Web Server, Modbus, and BACnet Interface Communication Option. Page 4 of 5

Dimensions Inches (mm) Page 5 of 5