INSTALLATION INSTRUCTIONS

Similar documents
INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Installation Instructions PANOS 5.25

INSTALLATION INSTRUCTIONS

PANOS. Installation Instructions Square, 5.25 Round Flangeless, Downlight. The following installation instructions relate to the options below

INSTALLATION INSTRUCTIONS

5Make electrical connections.

PH:

INSTALLATION INSTRUCTION In-Ground

Lumination TM Volumetric Retrofit Kit

INSTALLATION INSTRUCTION In-Ground Color Changing

LED Seamless VaporProof Fixture

ProStar Ceiling Fan PS52. Installation Instructions Instrucciones de instalación Instructions d installation

WARNING Risk of fire and electrical shock. DISCONNECT POWER AT ELECTRICAL PANEL before installing or servicing this product.

SCENE 2x2 INSTALLATION INSTRUCTIONS. Recessed T-Bar GENERAL SAFETY INSTRUCTIONS: NOTE:

CXB Series SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. LED Luminaire TO INSTALL: INSTALLATION INSTRUCTIONS INSTRUCTIONS D INSTALLATION

Juna Ceiling Fan JU54. Installation Instructions Instrucciones de instalación Instructions d installation

Standard Downrod for ceilings 8-10 feet high. Longer Downrod for ceilings 10 feet or higher

IMPORTANT: Read carefully before installation and retain for future reference. NOTE: Installation must be conducted by licensed electrician.

Hanson LED C e i l i n g F a n

Installation Instructions

Table of Contents What to Expect with Your Installation. Tools Needed. Wall Control

Lumination TM Controls Accessory LPL Series Controller Box

Table of Contents What to Expect with Your Installation. Ceiling Plate. Tools Needed.

Table of Contents. What to Expect with. Mounting Options. Tools Needed. Wall Control

PH:

INSTALLATION. Glass Panel Doors (select models) CAUTION

Table of Contents What to Expect with Your Installation. Tools Needed. Wall Control

SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE

Installation Instructions

GE Monogram. Automatic. Icemaker. Installation Instructions. Models ZDI15 ZDIS15. monogram.com

INSTALLATION INSTRUCTIONS

Table of Contents. What to Expect with. Mounting Options. Tools Needed. Preparation. Wiring. Downrod.

Safety Information BEFORE YOU BEGIN CAUTION: CAUTION: CAUTION: IMPORTANT Observe all governing codes. IMPORTANT Use this oven only

Owner s Guide and Installation Manual

3MAVR60XX Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 3MAVR60XX

Table of Contents What to Expect with. Mounting Options. Tools Needed. Downrod. Blades

Fillmore Small Pendant Assembly and Installation Instructions

INSTALLATION INSTRUCTIONS

Installation guide. Philips EvoKit LED 2x4 and 2x2

1 x4 Dimmable LED RetroFits

Owner s Guide and Installation Manual

Install Guide MXS-BRO SERIES SMALL BRO LED MULTIPLE RECESSED

Table of Contents What to Expect with Your Installation. Top Housing. Ceiling Plate. Tools Needed.

CEILING FAN OWNER S MANUAL

Installation Instructions

FES - Series Portable Electric Heaters

MaxLite 4, 6, 8 & 9 LED Architectural & Commercial Downlights

3MAVR60XXD Series Fan. Owner s Guide and Installation Manual. CUL Model NO. : 3MAVR60XXD

Table of Contents What to Expect with Your Installation. Tools Needed. Motor Housing.

DP25 & DR25 RECESSED T-BAR INSTALLATION INSTRUCTIONS

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

60" Lyndon Patio. Instruction Manual Customer Service :30 AM to 5:00 PM EST, Monday - Friday A Kichler Decor ceiling fan

Installation Instructions

Owner s Guide and Installation Manual

Table of Contents. 1 M /10/14 Casablanca Fan Company. What to Expect with Tools Needed.

ST. KITTS CEILING FAN

Table of Contents. What to Expect with. Mounting Options. Tools Needed

Installation Instructions

Installation. Leveling

Installation Instructions

Tetra MAX. LED Lighting System. BEFORE YOU BEGIN Read these instructions completely and carefully. Installation Guide

DHL-LP-LED Low Profile LED Linear High/Low Bay

Installation Instructions

CELEBRITY DELUXE 52" indoor fans

HPNLS-LO. Installation Manual

INSTALLATION MANUAL. Decoration panel BYFQ60C3W1W BYFQ60C3W1S MODELS

e Bath Fan with Light User s Guide

5LCM52XX Series Fan. Owner s Guide and Installation Manual. UL Model NO. : AC-552AL

54" Skye. Instruction Manual Customer Service :30 AM to 5:00 PM EST, Monday - Friday A Kichler Decor ceiling fan

Owner s Guide and Installation Manual

Installation Instructions If you have questions, call or visit our website at:

1. SAFETY RULES. 8. Avoid placing objects in the path of the blades.

INSTALLATION INSTRUCTIONS

TOUCHDOWN 48 CEILING FAN

CircoloTM A Kichler Décor ceiling fan Designed to coordinate with a popular Kichler Lighting collection.

Installation Instructions. Instructions de montage. Instrucciones de instalación HC

Installation Instructions

USER MANUAL INSTALLATION GUIDE FOR: 2X2: MLFP22DS4035 MLFP22DS4041 MLFP22DS4050

LED Flat Panel Retrofit

AGA TOTAL CONTROL. Model No. - TC3

3MNLR72XXD Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 3MNLR72

Table of Contents. What to Expect with. Mounting Options. Tools Needed. Downrod. Blades. Maintenance & Cleaning.

C-IV 60 CEILING FAN READ AND SAVE THESE INSTRUCTIONS. FAN RATING AC 120V. 60Hz

FOR SERVICE TECHNICIAN ONLY DO NOT REMOVE OR DESTROY L WASHER. Risque de choc électrique. Riesgo de Descarga Eléctrica

Ceiling Fan Installation Instructions

Torrena 42 Ceiling Fan

INSTALLATION INSTRUCTIONS

Camarillo 52 Ceiling Fan

ELSTON 52 CEILING FAN

52 Lacey LED. Instruction Manual. 6 Speed DC Wall Control System

Orrin. Instruction Manual. Includes our new CoolTouch TM Control System Looks permanent, but goes wherever you go! U.S.

CEILING FAN OWNER'S MANUAL

LIMITED LIFETIME WARRANTY

GE Monogram. Installation Instructions. Built-In Dishwashers. with Optional Trim Kit. Models ZBD5600 ZBD5700 ZBD5900

Table of Contents. What to Expect with. Tools Needed. Mounting Options. Blades

Gunnar Ceiling Fan. model no OWNER S MANUAL

HYDRA FR-W L; FR-W L; FR-W L

Please read and save these instructions. Should you have any questions or difficulty installing your fan, call us first!

Inde-Pendants Family. 32L Cylinder Plaster Trim, Grid and Drywall Ceiling Types. Document No

Transcription:

WHEN REPLACING PCB ASSEMBLIES, PLEASE WEAR AN ESD WRIST STRAP AND CONNECT IT TO ELECTRICAL GROUND RISK OF FIRE AND ELECTRICAL SHOCK Contact, improper installation, or improper servicing MAY RESULT IN DEATH OR SERIOUS INJURY! Fixture must be installed by a qualified electrician only. Fixture is intended for installation in accordance with the National Electrical Code, local and federal code specifications. Disconnect power at electrical panel before servicing. Retain these instructions for maintenance reference. ADVERTENCIA: RIESGO DE INCENDIO O IMPACTO ELÉCTRICO Conexión, instalación inapropiada o servicio incorrecto PUEDE CAUSAR MUERTE O HERIDAS GRAVES.La luminaria debe ser instalada únicamente por un eléctrico califi cado. La luminaria debe instalarse de acuerdo al Norma eléctrica nacional, al igual que especificaciones locales y normas federales. Se debe desconectar la corriente eléctrica antes de realizar la mantención. Conservar estas instrucciones como referencia para futuras mantenciones. ATTENTION: RISQUE D INCENDIE ET D ELECTROCUTION Une installation, un entretien ou un contact physique non conforme pourraient mener à un DANGER DE MORT OU DE BLESSURE GRAVE! L appareil doit être installé uniquement par un électricien professionnel qualifi é. L installation doit respecter le code électrique national de même que les lois locales et fédérales en vigueur. Veuillez fermer l alimentation électrique au panneau principal avant tout entretien. Conserver ces instructions pour référence et tout entretien futur. NOTE National or municipal codes must be followed regarding fixture installation and set back of thermal insulating material from luminaire. As a guideline, any insulation material must be held away from the luminaire by a minimum of 3". Fixtures are not designed for direct contact with thermal insulation. The following installation instructions relate to the options below 3.5" PANOS Accent, Flanged, Square 3.5" PANOS Accent, Flanged, Round Fixture and driver module are each ordered separately. Fixture ships with installation ring. Driver module ships with installation plate.

Installation Instructions STANDARD INSTALLATION INSTALLATION INSTRUCTIONS PANOS 2.25 PANOS 2.25 Square & Round, Flanged Square & Downlight Round, Flanged Downlight Standard Installation ceiling tile ceiling le ceiling tile installation plate (square) installa on plate (square) ceiling le installation plate (round) 1 Cut opening in ceiling. Ensure a minimum clearance of 2" around installa on plate proposed fixture 1 Cut location opening within in the ceiling Ensure before a beginning. minimum clearance of 2 around (round) 2 Place 2 Place installation plate* over over ceiling opening, opening, working working through SQUARE ROUND adjacent through ceiling tile. adjacent ceiling tile. 3-15/16 x 3-15/16" 3-15/16" Square diameter Round 2 Place installation plate* over ceiling opening, working through *For standard *For adjacent standard installation, installation, ceiling this step tile. this only step required is only for required accessible for accessible ceilings. ceilings. 2-11/16 x2-11/16 2-11/16 diameter *For standard installation, this step is only required for accessible ceili 1. 1. 2. 3 Install installation ring into ceiling Fastening springs will 4 Make electrical connections as shown. Ground rough-in using BLACK = LINE WHITE = NEUTRAL GREEN = GROUND BLACK LINE WHITE NEUTRAL GREEN GROUND DIM+ = E1 PURPLE DIM+/E1 DIM- = E2 GRAY DIM-/E2 the green 4 Make ground 4 Make electrical wire. electrical For non-dimming connections connectionsas installations, shown. cap Ground shown. off the rough-in two Ground control wires will the and the green connect green ground the ground hot, wire. neutral, For wire. non-dimming and For ground non-dimming as installations, normal. installations, For 0-10V cap off the cap off the tw using rough-in using fold down, 3 pull Install down on installation springs to secure ring into ceiling ceilingfastening structure. Adjust springs 3 mounting Install installation brackets fold down, so bottom ring pull into down of fl ceiling ange on is Fastening springs fl ush with to ceiling springs secure line. will ring (1-5/16 to ceiling dimming structure. two applications, trol control Adjust wires wires connect and and connect the DIM+ the to the hot, positive, neutral, and the and DIM- ground to the as as normal. For 0 flip ceiling over, thickness, pull down max.) on springs to secure ring to ceiling structure. negative. normal. Note: dimming Driver For 0-10V module applications, dimming may vary connect applications, based ceiling the connect DIM+ type. to the the DIM+ positive, to the and the DIM Adjust mounting ceiling brackets thickness, so bottom max.) of flange is flush with ceiling positive, negative. and Note: the DIM- Driver to module the negative. may vary based on ceiling type. line. (1-9/16" ceiling thickness, max.) Note: Driver module may vary based on ceiling type. Zumtobel Lighting, Inc. 2017 3300 Route 9W Highland, NY 12528-2630 February 10, 2017 10:02 AM 845-691-6262 800-448-4131 zli.us@zumtobelgroup.com www.zumtobel.us In a continuing effort to offer the best product possible, we zumtobel.us are the most recent version and supersede all other versions that exist in any other printed or electronic form. Page 2

Issue no. Issue date Issue by Issue chked. by Issue text Gen. tolerance: Sheetm. part tol.: Plastic part tol.: Info.: - Name: S.Remer Description Document I Chked. date: - Copyright according to ISO 16016 3RD Projection INSTALLATION INSTRUCTIONS STANDARD INSTALLATION (continued) 7 6 5 4 3 2 1 FEED WIRE LED feed wire D driver module feed FEED BY OTHERS C safety cord DRIVER MODULE driver module driver module B safety cord 1:1.333 5 For accessible ceilings place driver module through opening in adjacent tile. Secure fixture to permanent structure as per local code. Use bend up tabs as required. Surface treatment/aftertreatment: - Scale: 1:1 Project: - Basic material: - Size: D Date: 6/25/2018 - TRIPAR_T D- Chked. by: - - A 5 For inaccessible ceilings place driver module through ceiling cutout. 7 6 5 4 3 2 1 fixture power cable (female) fixture power cable (male) safety clip safety cord 6 Connect driver module to fixture as shown. Red = LED + Black = LED 7 Connect* safety cord to fixture with safety clip as shown. *This step is only required for inaccessible ceilings. 8 Insert fixture into housing For square fixtures, press upward firmly until fixture clicks into place, then install flange over edge of fixture. For round fixtures, twist until fixture clicks into place.

D C B A 8 7 6 5 4 3 2 1 Issue no. Issue date Issue by Issue chked. by Issue text Gen. tolerance: EN 22768 mk Sheetm. part tol.: DIN 6930-2 m Plastic part tol.: DIN 16742 Surface treatment/aftertreatment: - Project: - Basic material: - Description Name: S.Remer Chked. date: - Copyright according to ISO 16016 8 7 6 5 4 3 2 1 INSTALLATION INSTRUCTIONS EMERGENCY INSTALLATION ceiling cutout ACCESSIBLE CEILINGS X ceiling cutout EM pack EM PACK REMOVE WITH COVER TO ACCESS WIRING feed FEED BY OTHERS X pipe hole cutout pipe hole cutout LED feed LED FEED W/WHITE CONNECTOR DRIVER MODLUE driver module 1 Cut opening in ceiling and drill hole for EM button. Refer to page 2 for fixture cutout sizes. Dimensions for pipe hole size and position are below. In above diagrams, X refers to the distance between the centers of the two holes. Pipe Hole Diameter: ACCESSIBLE CEILING 3/8" INACCESSIBLE CEILING 7/16" SQUARE AND ROUND (INACCESSIBLE) 2-7/8" SQUARE (ACCESSIBLE) 3-3/8" ROUND (ACCESSIBLE) 2-11/16" EM TEST SWITCH CONNECTION test switch W/YELLOW CONNECTOR connection 2 Place installation plate over ceiling opening working through Date: 6/25/2018 - opening in adjacent ceiling tile. Ensure that holes in the plate Chked. by: - - align properly with ceiling cutout. 3 Install driver module in ceiling. 4 Install installation ring into ceiling as per standard instructions. 1:1.333 INACCESSIBLE CEILINGS RED BLACK UNSWITCHED = UNSWITCHED HOT HOT BLACK WHITE LINE = NEUTRAL WHITE GREEN NEUTRAL = GROUND GREEN DIM += GROUND E1 PURPLE DIM - DIM+/E1 = E2 GRAY ORANGE DIM-/E2 = SWITCHED HOT 5 Place installation plate over ceiling opening by folding plate and inserting it through ceiling cutout. Ensure that holes in the plate align properly with ceiling cutout. 6 Install installation ring into ceiling as per standard instructions. 7 Make electrical connections as shown. Ground rough-in using the green ground wire. For non-dimming installations, cap off the two control wires and connect the hot, neutral, and ground as normal. For 0-10V dimming applications, connect the DIM+ to the positive, and the DIM- to the negative. For EM installation, attach the switched hot to the orange line in the whip. Note: Driver module may vary based on ceiling type.

EMERGENCY INSTALLATION (Continued) accessible ceilings inaccessible ceilings 8 For inaccessible ceilings, insert driver module into ceiling and connect driver module to fixture as per standard instructions. 9 Connect driver module to test switch as shown above. Purple = + Brown = 10 Install fixture into ceiling as per standard instructions. 11 Install pipe hole cover into installation frame through ceiling cutout. The pipe hole cover will be held in place by a bracket that slides into place.

HANGER BAR INSTALLATION (Optional) ACCESSIBLE CEILINGS 1 Unpack hanger bar assembly. 2 Cut opening in ceiling using dimensions on page 2. 3 Attach installation plate to brackets Using a 8-32 self tapping screw (provided by Zumtobel). 4 Remove ceiling tile adjacent to the ceiling cutout. 5 Install hanger bar onto ceiling grid, working through the opening in the adjacent tile. Hanger bar length can be adjusted based on ceiling type. Secure fixture to permanent structure per local code. Construction wire may be looped through holes provided. 6 Replace adjacent ceiling tile and proceed with standard installation instructions. INACCESSIBLE CEILINGS Note: Hanger bar may only be installed prior to sheet rock installation. 7 Bend tabs on hanger bar ends until they are able to lay flush against stud. 8 Secure hanger bar onto stud per local code. Hammer in tabs on hanger bars to secure to wood or screw through holes in hanger bar with 3/16" lag screw. 9 Installation of fixture as per standard instructions may continue after sheet rock has been installed. Bracket height may need to be adjusted to ensure plate is flush with sheet rock.

MAINTENANCE Turn off power first! RELAMPING Contact Zumtobel at 1-800-448-4131 for replacement LED module. Please provide the original fixture description per the label inside the fixture. Once replacement LED module has been received, follow these steps. CLEANING Wipe with soft lint-free cloth. Do not use glass cleaner or other solvents. ACCESS TO DRIVER For Accessible Ceilings: Remove adjacent ceiling tile to access junction box and driver. The driver is mounted on junction box cover with internal wiring. For Inaccessible Ceilings: After trim removal continue pulling trim to access driver box housing and guide through ceiling opening. Remove cover on enclosure to access driver and wiring. 1 Please wear clean cotton gloves and electrostatic discharge protection. At the minimum, an ESD wrist strap should be worn and properly grounded. 2 Turn power off. 3 For square fixtures. Remove flange by gently prying off. Push upward gently on trim to release then pull out. 4 Disconnect LED wire at connector by gently pushing down on connector side clips then pulling apart. 5 Remove LED Board: Round Versions: Gently twist reflector CCW and remove from trim assembly. Using a thin blade screwdriver (or similar) gently pry back tabs on lens housing and remove from heatsink. Unscrew the 2 Torx screws and remove the LED board/board holder. Square Versions: Reflector snaps onto heatsink assembly. To remove, gently grab reflector and pry apart from heatsink assembly. Using a thin blade screwdriver (or similar) gently pry back tab on lens housing and remove from heatsink. Unscrew the '2' Torx screws and remove the LED board/board holder. 6 Using a scraper (putty knife) remove the old thermal film from casting and wipe clean with a clean cloth. 7 Remove transparent film protection from both sides of the new thermal film with your fingers. 8 Place the new thermal film on bottom of new LED board and align LED board in holder. 9 Align the mounting holes in LED board holder to the holes in the aluminum casted heatsink. 10 Using the 3mm Torx screws, and the screwdriver which has a blade length of 6 long, install the screws into holes on the LED board holder. 11 Reverse Procedure to reinstall fixture. 12 Turn on the power. 13 For disposal, please send the old LED module back to Zumtobel using the ESD bag provided.