Optimize your HVAC/R application with the right Danfoss components

Similar documents
food-retail.danfoss.com Overview Brochure ADAP-KOOL Evaporator Controllers Achieve best-in-class energy efficiency and food safety

The full range of Evaporator Controls from ADAP-KOOL

Capacity controller AK-PC 651

Controller for evaporator control AK-CC 750

Controller for appliance control AK-CC 550A

Instructions AK-PC 520

Controller for appliance control AK-CC 550B. Manual

Controller for appliance control AK-CC 450. Manual

Controller for appliance control AK-CC 550. Manual

AK SM 800 Commissioning Guide

Capacity controller for water chiller AK-CH 650

Temperature controller for limitation for the discharge gas temperature EKC 319A REFRIGERATION AND AIR CONDITIONING. Manual

Capacity controller EKC 331T REFRIGERATION AND AIR CONDITIONING. Manual

Capacity Controller AK-PC 351

Menu operation via AKM ADAP-KOOL. Compressor Pack Controller AKC 25H5. Software version 1.3x

Controller for Condensing unit Optyma Plus Evo 3 REFRIGERATION AND AIR CONDITIONING. Manual

Controller for operation of evaporator on water chiller EKD 316

Emerson Superheat Control. The smart solution for your application

User Guide. Controller for appliance control AK-CC 450

Liquid level controller EKC 347 REFRIGERATION AND AIR CONDITIONING. Manual

Controller for controlling one evaporator EKC 414A1 REFRIGERATION AND AIR CONDITIONING. Manual

SLV CONTROLLER 105N46XX SERIES

EKC 347 Liquid Level Controller REFRIGERATION AND AIR CONDITIONING. Manual

Capacity controller EKC 531D1 REFRIGERATION AND AIR CONDITIONING. Manual

Application and Installation Bulletin for Master-Bilt Refrigeration Superheat Controller Kit Assembly(A ), 120/208/240/1/60, R404A, LT/MT APPS

Controller for temperature control - EKC 202A,B,C and EKC 302A,B

Menu operation via AKA 21 ADAP-KOOL. Compressor Pack Controller AKC 25H5. Software version 1.3x

Controller for temperature control AK-CC 210

Refrigeration and Air Conditioning Technical leaflet. Electronic controller EKC 201 and EKC 301

80% leak risk reduction through fully hermetic coupling. Reduce lifecycle costs Increase savings and design freedom.

Controllers for controlling evaporators AKC 114, AKC 115, AKC 116 AKC 114D, AKC 115D, AKC 116D AKC 114A, AKC 115A, AKC 116A. Function description

Refrigeration and Air Conditioning Controls. Applications. PM Modulating pressure and temperature regulators REFRIGERATION AND AIR CONDITIONING

for for Industrial Refrigeration

80% leak risk reduction through fully hermetic coupling. Reduce lifecycle costs Increase savings and design freedom.

Monitoring unit with alarm function and data collection AK-SM 350 REFRIGERATION AND AIR CONDITIONING. Manual

Zero Superheat Control

Digital regulator for refrigeration and defrosting, 3 relays.

INSTRUCTIONS AK-CC 250A

Go Beyond Cool. coldroom.danfoss.co.uk. Danfoss Solutions for Cold Rooms Installers/Contractors, Europe. Over

Natural Refrigeration with Hydrocarbons Emerson s R290 Solutions

Capacity controller for dry cooler AK-PC 420

Go Beyond Cool. coldroom.danfoss.com. Danfoss Solutions for Cold Rooms - Installers/Contractors, Europe. Over

Refrigeration and Air Conditioning Controls. User s manual. Degree Master Controller in AKC 55 Systems ADAP-KOOL REFRIGERATION AND AIR CONDITIONING

Emerson R290 Solutions for Commercial Refrigeration Applications

MAKING MODERN LIVING POSSIBLE. Performer VSD. For Residential Applications - R410A. Quick reference

30 radiators from one central point. Simply smarter heating. living.danfoss.com. living by Danfoss heating control

Instructions AK-CC 550A 115 V

Recalibrate the way you look at gas detection

NEW INNOVATION CENTER

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

Outdoor Refrigeration Unit - ZX Range High Efficiency In Compact Design

Controller for temperature control EKC 202D1

Outdoor Condensing Unit - ZX Range. High Efficiency In Compact Design

EC3-X33 Stand-alone Superheat Controller Technical Data

Copeland Scroll Outdoor Refrigeration Unit

Capacity regulators, type CPCE and LG REFRIGERATION AND AIR CONDITIONING. Technical leaflet

DANFOSS OPTYMA PLUS INVERTER UNITS

Menu operation via AKA 21 ADAP-KOOL. Controller for controlling evaporators AKC 114D, 115D and 116D. Software version 1.5x

2,500 tons CO2 emission reductions 20% Application guide to CO2 secondary coolant systems

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA

Introduction to the FRIGOLINK system (Status as of )

AIR HANDLING UNITS RIS P EKO 3.0. New range - 5 sizes, 20 models! Efficient EC. E f f i c i e n c y up to 94%! E x t r e m e l y low height! fans!

Corrigo E. Second generation which contains all applications and languages

Elevating Your Offering

FSW SECTION. Product guide. Expansion Valves, Solenoid Valves Water Valves & Oil Pressure Switches F SECTION. 71

50% Refrigeration solutions to lower energy costs and reduce environmental impact. Foodservice Solutions. Up to

CT EN rel. 10/09 Copyright Eliwell Controls s.r.l All rights reserved

Monitoring and Controls

ER65 - Mini Rack Controller Electronic Refrigeration Line

Technical Information

Improving Cold Chain Competitiveness with Danfoss Energy Efficiency Solutions.

Bottle cooler controllers Solutions for static, ventilated and open coolers

Save energy and protect the environment

The DC-3 is a revolutionary system which will redefine our industry with a plug and play solution for walk in/reach in cool rooms.

Revolutionary ETS Colibri valves Engineered to give you maximum flexibility and dependability

CATALOGUE 2017 ELECTRICAL BOARDS FOR REFRIGERATION

Rotary Screw Compressors. SM Series With the world-renowned SIGMA PROFILE Flow rate 0.39 to 1.64 m³/min, Pressure 5.5 to 15 bar COMPRESSORS

Technical Information

EC3-X33 Stand-alone Superheat Controller

AIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw

Hi-Pres Cooling Products Catalogue. Product Catalogue

Danfoss gas detection units

ENTOUCH ONE USER GUIDE

MLC Air Cooled Chillers MLC-FC Free Cooling Chillers MLC-AD Adiabatic Chillers

AIR COOLED CONDENSING UNIT

AIR COOLED CHILLER FOR OUTDOOR INSTALLATION FROM 4,3 TO 35,1 kw

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

SAUTER EY-modulo 5. The complete building management solution.

Chapter-8 Capacity Control of Refrigeration Systems

INVERTER SCROLL. LG Electronics Distributed by. Copyright 2017 LG Electronics. All rights reserved.

HYDROCIAT LW R407C. Water cooled chillers USE RANGE

Technical Information

POCKET GUIDE 2011 ELECTRICAL BOARDS FOR REFRIGERATING INSTALLATIONS

One. Save time and money Streamline your heat pump business! makes a difference.

MCX ELECTRONIC CONTROLLER

AIR COOLED CONDENSING UNITS

Function description ADAP-KOOL. Controller for capacity regulation of brine installation AKC 25H7

AK-CS On Board Guide

WLM3 the 3 rd generation of the OJ Waterline TM Control Systems. Industry leading intelligence, control SLIDE OJ Electronics

EC 160 CO 2. Incubator

Transcription:

ADAP-KOOL Selection Guide Optimize your HVAC/R application with the right Danfoss components One- Stop-Shop for flexible control solutions

Engineering Tomorrow s Food Retail Solutions Enterprise Manager Danfoss Electronically Delivered Services X ML Open XML interface for 3rd party integration Remote Management Tool Web Browser Store View Desktop System Manager Pack Control Evaporator Control Site Service App HVAC, Light, Aux. Control High-End Basic TXV Controller Tray EEV Heat Exchangers Sensors Aux. Components High End HFC / CO2 Mid-Range HFC Drives CO2 Valves Balancing Valves 3rd Party HVAC, Basic Control Customized Solutions Light, Controllers I/O Modules Condensing Units Compressors Humidity Sensors Light Sensors Gas Sensors Energy Meter Contents Larger commercial and industrial applications EKC 35 (AKV)..................................................... 4 EKC 36 (ETS)....................................................... 5 Remote display cases/cold room control AK-CC 20 (TXV)................................................... 6 AK-RC 0/03 Optyma Controller (TXV)................. 7 AK-CC 550A (AKV)................................................. 8 Pack control Mini Rack (AK-PC 35)........................................... 9 Mid-eange rack (AK-PC 55) suction group..................................................0 2 suction groups................................................. System management Small store system management (AK-SM 820)......... 2 Stand alone evaporator control Commercial refrigeration/ freezer ERC 2X relay................................................................ 3 3 relay................................................................ 3 4 relay............................................................... 3

Temperature Control in stand-alone cabinets with ERC 2X Temperature Controller Multipurpose refrigeration control. Temperature and defrost management for commercial refrigeration applications Ease of use with four pushbuttons and pre-installed application set-ups Simple installation with direct connection of heavy loads Energy efficient control Safe and reliable operation, 3 or 4 Relay versions 20 or 240 V versions Sensor inputs: NTC5000 Ohm at 25 C NTC 0000 Ohm at 25 C PTC 000 Ohm at 25 C PT 000 Ohm at 25 C Protection: Front IP65 Defrost on demand Day/Night mode Smart evaporator fan management. Thermostatic expansion valve type TU 2. Temperature controller ERC 2X 3. Temperature sensor NTC 4. Secop compressor type SC M +2 C M Temperature Controller ERC 2, 20 V, relay 080G3290 (080G3262*) ERC 2, 240 V, relay 080G3293 (080G3263*) ERC 23, 20 V, 3 relay 080G329 (080G3264**) ERC 23, 240 V, 3 relay 080G3294 (080G3265**) ERC 24, 20 V, 4 relay 080G3292 ERC 24, 240 V, 4 relay 080G3295 or 2 EKS 2 NTC Sensor 5k Ohm.5 mt 084N220 or 2 EKS 22 NTC Sensor 0K Ohm 3.5 mt 084N320 Thermostatic Expansion Valve, TU Quick Selection Catalogue Chapter SECOP Compressor type SC Quick Selection Catalogue Chapter 8 *) Kit versions including NTC Sensor **) Kit versions including 2 NTC Sensors 3

Superheat Control in Refrigeration Plants with EKC 35A with AKV Superheat control in cold stores, processing plants or A/C plants with PWM Valve The evaporator is charged optimally even when there are great variations of load and suction pressure Exact temperature control the combination of adaptive evaporator and temperature control ensures great temperature accuracy for the media The superheating is regulated to the lowest possible value at the same time as the average temperature is controlled by the thermostat function Regulation of superheat Temperature control MOP function ON/OFF input for start/stop of regulation Input signal that can displace the superheat reference or the temperature reference Alarm if the set alarm limits are exceeded Relay output for solenoid valve PID regulation Output signal following the temperature showing in the display The adaptive regulation of the refrigerant injection ensures optimum utilization of the evaporator and hence a high suction pressure. Superheat controller EKC 35A 2. Electric expansion valve AKV 3. Temperature sensor AKS 4. Pressure transmitter AKS 33 M M Superheat controller, EKC 35A 084B7086 Data communication module RS485, EKA 74 084B724 Pressure transmitter, AKS 33 (/4 flare - to 2 bar) 060G2049 2 Temperature sensor, AKS (5.5 m cable, -50 to 00 C) 084N0005 Electric Expansion Valve, AKV Quick Selection Catalogue Chapter 2 4

Superheat Control in Refrigeration Plants with EKC 36A and ETS Superheat control in Cold stores, processing plants or A/C plants with Stepper Valve The evaporator is charged optimally even when there are great variations of load and suction pressure. Energy savings The superheating is regulated to the lowest possible value at the same time as the media temperature is controlled by the thermostat function. Regulation of superheat Temperature control MOP function ON/OFF input for start/stop of regulation Input signal that can displace the superheat reference or the temperature reference Alarm if the set alarm limits are exceeded Relay output for solenoid valve PID regulation The adaptive regulation of the refrigerant injection ensures optimum utilization of the evaporator and hence a high suction pressure. Evaporator controller EKC 36A 2. Solenoid valve EVR 3. Temperature sensor AKS 4. Pressure transmitter AKS 33 5. Stepper valve ETS M M Superheat Controller, EKC 36A 084B7088 EKA 74 data communication module RS485 084B724 Pressure transmitter, AKS 33 (/4 flare - to 2 bar) 060G2049 2 Temperature sensor, AKS (5.5 m cable, -50 to 00 C) 084N0005 Solenoid Valve, EVR Quick Selection Catalogue Chapter 3 Stepper Valve, ETS Quick Selection Catalogue Chapter 2 5

Basic Evaporator Control with TXV with Case Controller AK-CC 20 Basic evaporator control for display cases with thermostatic expansion valve (TXV) 6 Easy set-up with application macros HACCP compliant temperature measurement accuracy Optional LON or Modbus data communication for integration to ADAP-KOOL system Control of 2 compressors Robust and proven design Case controller AK-CC 20 System manager AK-SM 800 Solenoid valve EVR Thermostatic expansion valve type TU Temperature sensor AKS Scroll compressor Multi purpose Digital inputs Light control Case cleaning function Door contact function Electrical, natural or hot gas defrost Anti-cycle timer for optimum protection of compressor Direct connection of compressors Pcs 2 Day and Night functions Defrost on demand Door function ADAP-KOOL connection Description Case Controller, AK-CC 20 Data communication module MODBUS Temperature sensor, AKS (5.5 m cable, -50 to 00 C) Thermostatic Expansion Valve, TU Solenoid Valve, EVR Scroll Compressor Code Number 084B8520 084B8564 084N0005 Quick Selection Catalogue Chapter Quick Selection Catalogue Chapter 3 Quick Selection Catalogue Chapter 8. 2. 3. 4. 5. 6.

Basic Room Control with Optyma Controller AK-RC 0/03 Basic evaporator control for cold rooms with thermostatic expansion valve (TXV) and condensing unit Complete cold room control solution with built in protection and circuit breaker Single and Three phase Simple wiring ADAP-KOOL integration via Modbus Protected housing IP65 LED icons to signal plant status Electronic control with wide LED display and easy to use buttons Display and adjustment of cold room temperature accurate to 0. deg. C Display of evaporator temperature from parameter Alarm signalling: sensor errors, min. and max. temperature alarm, compressor protection. Evaporator fan control Automatic and manual defrost control Room light activation. Optyma control - AK-RC 0/03 2. System manager AK-SM 800 3. Solenoid valve EVR 4. Thermostatic expansion valve TU 5. Temperature sensor NTC 6. Condensing unit - Optyma plus Optyma controller (incl. 2 pcs. EKS 22 temperature sensors) AK-RC 0, single phase 080Z3200 AK-RC 03, Three phase (3 kw) 4.5-6.3A 080Z320 AK-RC 03, Three phase (3 kw) 7-0A 080Z3202 AK-RC 03, Three phase (5 kw) -6A 080Z3206 AK-RC 03, Three phase (5 kw) 4-20A 080Z3207 2 EKS 22 NTC Sensor 0K Ohm 3.5 mt 084N320 Optyma Plus New Generation Quick Selection Catalogue Chapter 9 Thermostatic Expansion Valve, TU Quick Selection Catalogue Chapter Solenoid Valve, EVR Quick Selection Catalogue Chapter 3 7

High-end EEV case control with case controller AK-CC 550A and AKV Energy optimized evaporator control with electronic expansion valve (AKV) Proven and robust control solution Easy set-up with application macros and no further adjustment of vales or superheat Adaptive superheat control for premium energy efficiency AKV valve with normally closed functionality avoids refrigerants floating back to compressor at power outage Operates with HFC and CO2 ON/OFF or modulating control Product sensor S6 with separate alarm limits Build-in Modbus, Opt. LON Sensor Inputs 6xPT000 and xpressure transmitter (AKS32R) Supply voltage 230 V ADAP-KOOL Integration Adaptive superheat Optimum utilization at all load conditions. Adaptive Defrost Rail heat optimization Day and night functions (case temperature, blinds and lights) Hot gas defrost Typical 8-2% energy savings compared to TXV or other EEV solutions with fixed superheat. 8 Temperature display EKA 63B Case controller AK-CC 550A System manager AK-SM 800 Electric expansion valve AKV Temperature sensor AKS Pressure transmitter AKS 32R Scroll compressor Pcs 5 Description Case controller with MODBUS Data Communication, AK-CC 550A Temperature sensor, AKS (5.5 m cable, -50 to 00 C) Pressure transmitter, AKS 32R (/4 flare - to 2 bar) Electric Expansion Valve, AKV Data Communicatio Modules and display Code Number 084B8030 084N0005 060G036 Quick Selection Catalogue Chapter 2 Quick Selection Catalogue Chapter 6. 2. 3. 4. 5. 6. 7.

Small HFC pack control with Pack Controller AK-PC 35 Capacity regulation of compressors and condensers in small size refrigeration applications Covers most commonly used HFC pack applications for commercial refrigeration Fast and Easy wizard setup Robust control with optimised control algorithms and factory default Energy saving features to reduce operating costs Graphical, easy to use interface suction group Up to 4 compressors and 4 condenser fans (Maximum 6 in total) Variable speed on lead compressor Variable speed on condenser fans Built in display Modbus connection to AK-SM 800 or AK-SC 355 ADAP-KOOL Integration Suction Pressure Optimization Night Setback Floating condenser control. AK-PC 35 Pack controller 2. System manager AK-SM 800 3. VLT Frequency converter FC 03 4. Pressure transmitter AKS 32R 5. Scroll compressor 6. Temperature Sensor Pack Controller AK-PC 35 (24 V) 080G0289 Pressure transmitter AKS 32R for suction (/4 flare - to 2 bar) 060G036 Pressure transmitter AKS 32R for discharge (/4 flare - to 34 bar) 060G0090 2 Plug with 5 m cable 060G034 Temperature sensor AKS for suction (5.5 m cable, -50 to 00 C) 084N0005 Temperature sensor AKS 2A for discharge (5 m cable, -70 to 80 C) 084N0008 Speed drive FC-03 for lead compressor and condenser consult FC-03 configuration tool (drives.danfoss.com) Scroll Compressor Quick Selection Catalogue Chapter 8 9

Mid-range HFC pack control with Pack Controller AK-PC 55 one suction Capacity regulation of compressors and condensers in medium size refrigeration applications Covers most commonly used HFC pack applications for commercial refrigeration Fast and Easy wizard setup Robust control with optimised control algorithms and factory default Energy saving features to reduce operating costs Graphical, easy to use interface suction and condenser group Up to 8 compressors and 8 condensers (Maximum 8 in total) PI control with Neutral Zone settings 8 DO, 8 DI, 8 AI and 2 AO Variable speed on lead compressor Variable speed on condenser fans Built in display and remote display Can control Copeland Digital Scroll, Copeland Stream with 4 cylinders and Bitzer CRII with 4 cylinders ADAP-KOOL Integration Suction Pressure Optimization Night Setback Load shedding Floating condenser control Heat recovery set point via DI Night silence function. Pack controller AK-PC 55 2. Remote graphical display MMIGRS2 3. System Manager AK-SM 800 4. VLT Frequency converter FC 03 5. Pressure transmitter AKS 32R 6. Temperature sensor AKS 7. Scroll compressor Pack Controller AK-PC 55 with built-in display 080G028 (230 V) or 080G0283 (24 V) Remote Display MMIGRS2 080G0294 Wire for Display 080G0075 (.5 m) or 080G0076 (3 m) Pressure transmitter AKS 32R for suction (/4 flare - to 2 bar) 060G036 Pressure transmitter AKS 32R for discharge (/4 flare - to 34 bar) 060G0090 2 Plug with 5 m cable 060G034 Temperature sensor AKS for suction (5.5 m cable, -50 to 00 C) 084N0005 Temperature sensor AKS 2A for discharge (5 m cable, -70 to 80 C) 084N0008 Variable Speed drive FC-03 for lead compressor and condenser Consult FC-03 configuration tool (drives.danfoss.com) Scroll Compressor Quick Selection Catalogue Chapter 8 0

Mid-range HFC pack control with Pack Controller AK-PC 55 two suctions Capacity regulation of compressors and condensers in medium size refrigeration applications Covers most commonly used HFC pack applications for commercial refrigeration Fast and Easy wizard setup Robust control with optimised control algorithms and factory default Energy saving features to reduce operating costs Graphical, easy to use interface suction and condenser group Up to 8 compressors and 8 condensers (Maximum 8 in total) PI control with Neutral Zone settings 8 DO, 8 DI, 8 AI and 2 AO Variable speed on lead compressor Variable speed on condenser fans Built in display and remote display Can control Copeland Digital Scroll, Copeland Stream with 4 cylinders and Bitzer CRII with 4 cylinders ADAP-KOOL Integration Suction Pressure Optimization Night Setback Load shedding Floating condenser control Heat recovery set point via DI Night silence function. Pack controller AK-PC 55 2. Remote graphical display MMIGRS2 3. System Manager AK-SM 800 4. VLT Frequency converter FC 03 5. Pressure transmitter AKS 32R 6. Temperature sensor AKS 7. Scroll compressor Pack Controller AK-PC 55 with built-in display 080G028 (230 V) or 080G0283 (24 V) Remote Display MMIGRS2 080G0294 Wire for Display 080G0075 (.5 m) or 080G0076 (3 m) 2 Pressure transmitter AKS 32R for suction (/4 flare - to 2 bar) 060G036 Pressure transmitter AKS 32R for discharge (/4 flare - to 34 bar) 060G0090 3 Plug with 5 m cable 060G034 Temperature sensor AKS for suction (5.5 m cable, -50 to 00 C) 084N0005 Temperature sensor AKS 2A for discharge (5 m cable, -70 to 80 C) 084N0008 Variable Speed drive FC-03 for lead compressor and condenser Consult FC-03 configuration tool (drives.danfoss.com) Scroll Compressor Quick Selection Catalogue Chapter 8

System Managment for small stores with System Manager AK-SM 820 Controlling and monitoring of refrigeration, HVAC, light and misc. Applications Control and monitor all key applications Access the system via local screen/keypad, via web browser or tablet/smartphone Customized screens for fast diagnostics Set-up wizards Up to 32 generic device support Wall or panel mounting RS485 LON Ethernet Modbus USB Connects to all Danfoss ADAP-KOOL controllers Suction pressure optimization Master control functions Control of refrigeration, Light, HVAC and misc. points via decentral controllers or directly from frontend (schedules, override, simple logic) Description Code Number System Manager AK-SM 820 080Z4004 Evaporator Controllers Quick Selection Catalogue Chapter 6 Compressor Controllers Quick Selection Catalogtue Chapter 6 HVAC, Light, Misc. Control and Sensors: I/O modules (Contact Danfoss) Moisture and Temperature Sensor 080Z27 Indoor Light Sensor 080Z277 Outdoor Light and Temperature Sensor 080Z272 Gas Detection Quick Selection Catalogue Chapter 7 Energy Meters, WattNode Modbus 080Z246 2