THE COMPLETE SPECTRUM OF SIGNALING TECHNOLOGY

Similar documents
Are you ready for EN 54-23? New requirements for fire alarm systems from 1 January 2014

Heaters, Thermostats and Hygrostats

Signaling Solutions for Alarm, Warning, and Indication

Opal TM AV Devices. Data Sheet. Benefits

Notifier by Honeywell: Non-Addressable Audible & Visual Alarm Devices. Approved to EN54-3/EN54-23

UV Flame Supervision System

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

COMPACT FLAME CONTROLLER CFC 2000

Class 1 laser beam sensor safe for your eyes

Evacuate everyone Sonos Pulse & Nexus Pulse

Signaling Devices. Acoustic Signaling Devices 298. Optical Signaling Devices 309. Bosch Security Systems B.V.

Class 1 laser beam sensor safe for your eyes

LFE50. UV Flame Safeguard. Siemens Building Technologies HVAC Products DETACTOGYR. Series 02

CONVENTIONAL AUDIBLE VISUAL

Contents. Best Trusted and Rated Quality Products. PX-1 Stand-Alone Smoke Alarm. PX-1C Radiolink Smoke Alarm. PX-AR Alarm Relay

Class 1 laser beam sensor safe for your eyes

COMPACT FLAME CONTROLLER CFC 1000

PATROL SOUNDERS 100/105 db(a) PA 1 / PA 5

LED Product Catalogue

PATROL SOUNDERS 110/120 db(a) PA 10 / PA 20

VISAGE ENVIRONMENTAL LIGHTING SOLUTION. INDOOR Lighting SERIES

Celebrating YEARS Manufacturers of Visual & Audible Signalling Devices. NEW Exd

LFE50. UV Flame Safeguard. Building Technologies Division DETACTOGYR

25W Explosion Proof Surface Mount LED Light - C1D1-2 - C2D1-2 - Aluminum Frame V AC

ELECTRONIC SOUNDER STROBE Model : AVD-C407

ATEX. IECEx. culs GOST-R. VdS

Rotary Screw Compressors SX Series With the world-renowned SIGMA PROFILE Free air delivery from 0.26 to 0.81 m³/min, Pressure 5.

Features. Omni2 Door Warning Sign Alarm Annunciator DATASHEET. Model C1190B Door Warning Sign

Data sheet. Function description. Benefits

Thermal management of electrical enclosures. Stronger than the elements. Pfannenberg units for outdoor thermal management.

SAFETY AT SCHOOLS. We supply sound, not equipment. the integration of intercom and voice alarm systems makes schools safe.

Bulb Overview DESCRIPTION PART NO. TOTAL VOLTAGE FOR USE WITH: LENGTH(mm) Free-standing Beacons Accessories. Optical Signal Devices

150W Explosion Proof High Bay LED Light Fixture - C1D1&2 - C2D1&2-17,500 Lumens - 60 Beam

Movement-based energy control

Consultant Specification AGILE Wireless Fire Detection System

Refrigeration Dryers TG TI Series

Dräger Flame 2100 Flame Detection

On the job around the clock 24/7: Fire detection systems

Opal TM AV Devices. Data Sheet. Benefits

Hazardous Area Signalling

C1D1 Explosion Proof 50W LED Flood Light Fixture - Paint Spray Booth Approved - Adj Surface Mount

11:00 to 12:00 Secrets to achieving code-compliant strobe installations. Ralph Coco, Potter Canada Paul Jewett, Mircom Group of Companies

Matrix2000. User Guide - CPD Advanced Analog Fire Alarm Control Panel 4 24 Zones. Version: 2.0 Revision: 1

Laser Distance Sensor Type M Analog-Output

C2D1/C1D2 Explosion Proof 50 Watt LED Light Fixture - Paint Spray Booth Approved - 6,250 Lumens

Industrial Horn & LED Strobe Warning System - 12V DC - Weatherproof - NEMA 4X - Class 1 Beacon

Snifter ATEX22 VERSION. User Manual. Distributor

Pyroelectric Infrared Sensor PIR

GRP Flameproof Combination Signal db(a) / 5 Joule Series YL6S

Dräger Flame 2500 Flame Detection

Fire Signalling. Signalling Solutions

FR-A180 FR-A360. Occupancy detector. Use

AWL AIRCRAFT WARNING LIGHT LIOL-B TYPE OPERATION AND MAINTENANCE MANUAL

Procedure for the Approval of New Fire Detection and Alarm Technologies

High-Performance Heaters for Patios, Industry and Catering

Laser Collimated Beam Sensor

INTRON-D plus. Alarm and Warning Function. Automatic and/or manual triggering of alarms and warnings to protect human lives and to evacuate people.

ICARO. Aircraft Warning Lights GENERAL CATALOGUE

The importance of signs and colors in industry and in areas with risk of explosion

CASE STUDY. Safety and system uptime in the St. Gotthard Base Tunnel

Model 3300 Technical Support and Installation Manual

COMPACT FLAME CONTROLLER CFC 200 (Formerly 8.XX)

Flame Detection Jon Sarfas

Instruktions manual. At skræmme fugle med laser!

TAH / TBH / TCH Series

EVL-B - Zone 1, 2, 21, 22 - Replaces traditional discharge lamps more than 400W - Saves in energy, maintenance and installation

Half-Dome. the Design-Tower. Compact

Obstruction Lighting

100W Explosion Proof Ultraviolet Portable LED Fixture - 365NM - EXP Cord Caps - 150ft Cord

Rotary Screw Compressors. SM Series With the world-renowned SIGMA PROFILE Flow rate 0.39 to 1.64 m³/min, Pressure 5.5 to 15 bar COMPRESSORS

Functional Safety of Machinery Presented by Greg Richards Manufacturing in America 02/22-23/2017

LaserFOCUS VLF-250 Engineering Specification

AD.3.XG... DIRECTIONAL CONTROLE CETOP 3

SICK AG WHITEPAPER. safehddm TM THE NEW SCANNING TECHNOLOGY FOR SAFETY LASER SCANNERS

3200 NON-ADDRESSABLE FIRE ALARM CONTROL PANEL

VIBRA-series: VIBRA, VIBRA +

RS Pro Infrared Temperature Sensor

TAH / TBH / TCH Series

ARRAN LED LED FLOODLIGHT. Standard Specification. Features

GL-CO-RFG Channel Gas Leak Alarm System

Model LTN-3R Outdoor Rated Uninterruptible Power System Single Phase

Spark Extinguishing Systems. Extinguish BEFORE Ignition. Fire Protection. Measuring Technology. Service. Fagus-GreCon Greten GmbH & Co.

6100 SINGLE LOOP DIGITAL ADDRESSABLE FIRE ALARM CONTROL PANEL

signaling solutions from auer signal

Technical reference Reference & design

Thermal Management and Signaling Technology

300W Low Profile Clean Room LED Light - LED Signal Light - C1D1 - C2D2 - ISO 14644/FS-209E Rated

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Phone: Fax:

SECTION INTERIOR LIGHTING

For Complete Fire and Gas Solutions

EN54 Part 23 Made Easy CPD PRESENTED BY SIMON ADAMS GENT BY HONEYWELL

Operating Instructions!

ICARO. Aircraft Warning Lights GENERAL CATALOGUE.

High bay LED lighting fixture

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

7XG3130 ReyArc30 Optical Arc Fault Sensor Energy Management

AUTOMAX devices for the automation industry

Sintrol Snifter A2 EX. Manual. Version 1.2.3

Multiple Status Indicators Series MEXE, MS25, MS35, MS45, MS55

IR FLAME DETECTOR RIV-601/F

Transcription:

THE COMPLETE SPECTRUM OF SIGNALING TECHNOLOGY ALARM INDICATION WARNING SIGNALING TECHNOLOGY MAIN CATALOGUE EDITION 14

INTRODUCTION 10 YEARS WARRANTY 2 www.pfannenberg.com

SAFETY FOR MAN, MACHINE AND THE ENVIRONMENT 60 YEARS OF PFANNENBERG YOUR COMPETENT PARTNER FOR VISUAL AND AUDIBLE INDICATION, WARNING AND ALARM SIGNALS We have continually been extending our portfolio by adding new product innovations since the fi rst fl ashing lights were invented about 50 years ago. Hardly any other company worldwide can supply from one source and advise so comprehensively in this area as Pfannenberg. Customer service and service friendliness are top priority for us: That s why, with immediate effect, we provide a 10 year warranty on sounders and fl ashing sounders from the PATROL, PYRA, DS and Quadro series. And by introducing the Easy Replacement Process, we have made it possible for our customers to exchange defective devices even more easily and quickly. Communication with our partners and customers is important to us. We are only able to tailor our products and services to your fi t your needs and provide solutions from one source by communicating with our customers. The Pfannenberg Sizing Software (PSS) which was developed by Pfannenberg helps you to choose the correct signaling solution. The software also contains modules for the calculation of thermal management solutions; you can fi nd a small selection in this catalogue. With our new series of flashing lights, PYRA M, Pfannenberg is responding to the increased demand for more process reliability in the fi eld of mechanical engineering and construction. The pyramid-shaped flashing light, which is also available as a combination device with an integrated sounder, guarantees the largest possible signaling range thanks to effi cient Xenon technology. Certifi ed according to EN 54-23, the new EU standard in the fi re alarm sector, the fl ashing lights are consistent with the Pfannenberg company motto: Safety for man, machine and the environment. Best regards Andreas Pfannenberg CEO Further technical information can be found on our website at www.pfannenberg.com 3

INTRODUCTION Pfannenberg supplies the entire range of signaling technology from one source, regardless for which application and area of use you want to implement the device. Furthermore, we offer appropriate solutions that are customized to the relevant requirements of the various areas of signaling technology: Indication Warning Alarm E. g. operation display of a machine informs the operator by means of a signaling device. These types of devices inform personnel who are nearby. These devices are not used for the indication of dangerous situations. The signaling can, e.g. contain the following information: - status of a machine, process, test procedure - lack of ingoing material / material supply is in danger - quality defect, good / defective information - process has ended, standby position - notifi cation and display of errors - display of room occupancy E. g. as a start-up signal for a machine. These types of devices warn about situations that could occur. The warning can, e.g. be executed for the following events: - caution: Critical status, proceed with caution - ready for handling - attention is necessary - dangerous situations can occur when no measures are in place - corrective action is necessary within a suitable amount of time - warning of economic and health damages - process is outside the normal operating limit but within an acceptable error limit - a status change is being executed Reaction of the user: Monitor and / or take corrective action E. g. the evacuation alarm in case of a fire. Devices of this nature generate an alarm for emergency situations and have the highest priority. The alarm can, e.g. be executed for the following events: - a dangerous situation has already occurred - danger of life and limb - acute health risk - risk for the environment - abnormal process status - exceeds maximum tolerance limits Reaction of the user: Immediate reaction is necessary 4 www.pfannenberg.com

5 GOOD REASONS TO CHOOSE PFANNENBERG ABSOLUTE SAFETY The Pfannenberg Group s signaling technology is innovative, modern and durable. It offers absolutely secure alarm ability. ALL-ROUND CARE Pfannenberg has organised sales in 42 countries on all 5 continents, thus ensuring optimal support. Whether it s about on-site service, comprehensive application advice or the creation of individual solutions, Pfannenberg offers its customers top support around the clock and around the world in the respective national language. INDIVIDUAL ADVICE The Pfannenberg Group offers its customers the necessary competence for individual solutions in the most diverse branches of industry (examples): Machine safety Renewable energies Building equipment Fire prevention Art illumination Function-monitored fl ashing lights Voice alarms in bio-gas combined heating and power plants Obstruction lights Acoustic alarms in gas-fi red power stations Illumination of the Eiffel Tower with 20,000 fl ashing lights SOFTWARE The Pfannenberg Sizing Software (PSS) helps you plan tailor made signaling technology solutions (dimensioning and select the correct signaling devices like fl ashing lights, sounders and signal towers). You can download the software free of charge on www.pfannenberg.com or order it on CD. PRODUCTION AROUND THE WORLD The Pfannenberg Group is constantly optimising its production in order to directly serve customers all over the world on a local basis and to establish a strong network. Pfannenberg links its production in Germany, Italy, USA and China optimally to plastics processing, state-of-the-art sheet metal working and VdS-approved manufacturing. Our own environmental simulation laboratory enables the manufacturing of tested products for the most extreme application conditions, naturally also with VdS and UL approval. Plastic injection moulding plant, Pfannenberg, Hamburg Further technical information can be found on our website at www.pfannenberg.com 5

INTRODUCTION TABLE OF CONTENTS INTRODUCTION... 2 The Pfannenberg Company... 3 Reliable signaling... 4 Quick Guides... 8 Extended warranty... 18 Technology... 20 VISUAL SIGNALING DEVICES... 40 Quick Guide... 42 Flashing lights... 46 LED lights... 70 Continuous lights... 86 Rotating mirror lights... 90 Function-monitored lights... 92 Safety-related lights (SIL/PL)... 100 Accessories and light sources... 104 Connection diagrams... 109 OBSTRUCTION LIGHTS...112 Low Intensity Lights...116 Medium Intensity Lights... 120 Accessories... 125 AUDIBLE SIGNALING DEVICES... 128 Quick Guide... 130 Sounders... 132 Safety-related sounders (SIL/PL)... 144 Electronic buzzers... 146 Connection diagrams... 148 6 www.pfannenberg.com

COMBINED VISUAL-AUDIBLE SIGNALING DEVICES... 150 Quick Guide... 152 Blinking LED Panel Mount Indicator with Buzzer... 153 Flashing Sounders... 154 LED Blinking Sounder... 154 Connection diagrams... 166 SIGNAL TOWERS... 168 Signal towers BR 50... 170 Function-monitored modules... 174 Signal towers BR 35... 177 Accessories and light sources... 180 EX SIGNALING DEVICES... 182 Technology... 184 Quick Guide... 190 Visual signaling devices... 192 Audible signaling devices... 206 Loudspeakers... 216 Combined visual-audible signaling devices... 218 Zener barriers... 224 Connection diagrams... 226 NEW THERMAL MANAGEMENT A CHOICE OF THE EXTENSIVE PORTFOLIO... 230 Cooling units... 233 Air/Water Heat Exchangers, Air/Air Heat Exchangers... 234 Chillers... 235 Filterfans... 235 Heaters... 236 Thermostats, Hygrostats... 237 Enclosure lighting systems... 237 PFANNENBERG WORLDWIDE... 238 Art Illumination... 238 Contact addresses... 244 Sales partners... 245 Further technical information can be found on our website at www.pfannenberg.com 7

INTRODUCTION ALL VISUAL SIGNALING DEVICES AT A GLANCE Type FLASHING LIGHTS Maximum covering distance as per EN 54-23 in metres (m) 1 Flash energy Protection system Dimensions (HxWxD) mm Approvals / Standards EN 54-23 RS GL GOST UL 2.5 5 10 25 50 MED VdS Page PMF 2030 30 joules 46 PMF 2020 7 joules IP 55 direct mounting 185 x Ø 177 bracket mounting 170.5 x Ø 130 48 PMF 2015 7 joules ABL / ABS 15 joules IP 54 without bracket 242 x Ø 80 50 P 400 STR 15 joules IP 65 220 x Ø 140 52 Quadro F12 Quadro S 13 joules 13 joules IP 66 IP 67 IK 08 130 x 130 x 130 54 2 PY X-M-10 10 joules IP 66 IK 08 124 x 166 x 114 2 56 NEW 2 PY X-M-05 5 joules IP 66 IK 08 124 x 166 x 114 2 58 WBL / WBS 5 joules IP 54 200 x Ø 54 60 WBL-PX 5 joules IP 54 200 x Ø 54 WBLR WBSR 5 joules IP 65 144 x 120 x 85 62 P 300 STR 5 joules IP 65 150 x Ø 100 64 1 with a clear lens available in preparation 2 option 8 www.pfannenberg.com

Overviews Type FLASHING LIGHTS Maximum covering distance as per EN 54-23 in metres (m) 1 Flash energy / light intensity Protection system Dimensions (HxWxD) mm Approvals / Standards EN 54-23 RS GL GOST UL 2.5 5 10 25 50 MED VdS Page 2 PY X-S-05 5 joules IP 66 IK 08 85 x 109.5 x 80.6 2 66 DWBL / DWBS 2.5 joules IP 54 200 x Ø 54 68 LED LIGHTS PMF-LED Flex 30 cd IP 55 direct mounting 185 x Ø 177 bracket mounting 170.5 x Ø 130 70 P 400 LDA 30 cd IP 65 220 x Ø 140 72 P 300 LDA 20 cd IP 65 150 x Ø 100 72 Quadro-LED Flex 9 cd IP 66 IP 67 IK 08 130 x 130 x 130 74 PD 2100-LED 5 cd IP 55 128 x 166.2 x 111.2 76 P 200 LDA 5 cd IP 65 80 x Ø 60 78 P 100 LDA 5 cd IP 65 65.5 x Ø 60 78 Quadro-LED-TL 80 cd IP 66 IK 08 130 x 130 x 396 80 1 with a clear lens available in preparation 2 option Further technical information can be found on our website at www.pfannenberg.com 9

INTRODUCTION ALL VISUAL SIGNALING DEVICES AT A GLANCE Type LED LIGHTS Maximum covering distance as per EN 54-23 in metres (m) 1 Light intensity / light power Protection system Dimensions (HxWxD) mm Approvals / Standards EN 54-23 RS GL GOST UL 2.5 5 10 25 50 MED VdS Page P 450 TLA 60 cd IP 65 177 x Ø 140 82 P 350 TLA 45 cd IP 65 140 x Ø 100 82 P 22 D IP 65 52 x Ø 29 84 P 22 DFS IP 65 52 x Ø 29 84 CONTINUOUS LIGHTS PD 2100 15 W IP 55 128 x 166.2 x 111.2 86 P 450 TSB 25 W IP 65 177 x Ø 140 88 P 450 TDB 2 x 15 W P 350 TSB 15 W IP 65 140 x Ø 100 88 ROTATING MIRROR LIGHTS P 400 RTH 35 / 40 W IP 65 220 x Ø 140 90 P 300 RTH 20 / 25 W IP 65 150 x Ø 100 90 1 with a clear lens available in preparation 10 www.pfannenberg.com

Overviews Type Maximum covering distance as per EN 54-23 in metres (m) 1 Flash energy / light intensity Protection system Dimensions (HxWxD) mm Approvals / Standards GL GOST UL 2.5 5 10 25 50 MED VdS FUNCTION-MONITORED LIGHTS EN 54-23 RS Page Quadro S-M-Flex 13 joules IP 66 IP 67 IK 08 130 x 130 x 130 92 WBL-M / WBS-M 5 joules IP 54 242 x Ø 80 94 PMF 2015-M 7 joules IP 55 direct mounting 185 x Ø 177 bracket mounting 170.5 x Ø 130 96 PD 2100-M-AS-i (LED) 5 cd IP 55 PD 2100-LED-M 5 cd IP 55 128 x 166.2 x 111.2 98 SAFETY-RELATED LIGHTS Quadro F12-SIL 10 joules IP 66 IP 67 IK 08 130 x 130 x 130 100 PMF 2015-SIL 10 joules IP 55 direct mounting 185 x Ø 177 bracket mounting 170.5 x Ø 130 102 ART ILLUMINATION Quadro R 10 joules Quadro R-ST 10 joules IP 66 IP 67 IK 08 130 x 130 x 130 242 Quadro A-DMX 10 joules 244 1 with a clear lens available in preparation Further information can be found on the Internet: www.pfannenberg.com www.pfannenberg-spareparts.com Keep up to date. Subscribe to our newsletter now: newsletter.pfannenberg.com Further technical information can be found on our website at www.pfannenberg.com 11

INTRODUCTION ALL OBSTACLE LIGHTS AT A GLANCE Type Approval Flash Sync. Twilight Switch Visibility Control Data Logger Onshore/ Offshore Wireless Network Page AVV ICAO type FAA type LOW INTENSITY POL 10-H A 116 POL 32-H B L-810 POL 10-M A POL 10-M-R A 118 POL 10-M-RA A POL 32-M B L-810 POL 170W-RED-ES 1 120 MEDIUM INTENSITY POL 2.000R-B B L-864 120 POL 2.000R-C C POL 20.000/2.000R-C A, C POL 20.000/ 170W-RED-ES POL 20.000/ 2.000R-B A A, B L-864 / L-865 122 POL 20.000/2.000W A L-865 standard option 1 ES = Extended Specifi cation acccording to AVV 12 www.pfannenberg.com

ALL AUDIBLE SIGNALING DEVICES AT A GLANCE Overviews Type Maximum covering distance for a 65 db ambient noise level in in metres (m) 1 Sound pressure level Protection system Dimensions (HxWxD) mm Approvals / Standards GL EN GOST UL 54-3 10 100 250 500 1500 MED VdS RS Page SOUNDERS DS 5 DS 10 105 db (A) 110 db (A) IP 66 IP 67 133.5 x 133.5 x 143 132 DS 5-DN 105 db (A) IP 66 IP 67 133.5 x 133.5 x 143 134 PA 1 100 db (A) IP 66 IK 08 86 x 109.5 x 80.6 2 2 136 PA 5 105 db (A) IP 66 IK 08 135 x 163.4 x 132 2 2 136 PA 10 110 db (A) IP 66 IK 08 170 x 214 x 156 2 2 138 PA 20 120 db (A) IP 66 IK 08 170 x 214 x 181 2 2 138 PA 130 130 db (A) IP 54 285 x 490 x 595 142 SAFETY-RELATED SOUNDERS DS 5-SIL DS 10-SIL 105 db (A) 110 db (A) IP 66 IP 67 133.5 x 133.5 x 143 144 ELECTRONIC BUZZERS P 22 DBZ 80 db (A) @ 10 cm IP 40 Ø 29 x 62 146 P 28 DMC948 P 28 DMC201 P 28 DMC948 P 28 DMC201 91 db (A) 91 db (A) 91 db (A) 91 db (A) IP 65 Ø 35.8 x 38.2 146 1 The specifi cation for the alarm signal reception range assumes an existing ambient noise level of 65 db (A). In accordance with applicable regulations, the calculated alarm range for the sound level 65 db (A) was given + 10 db (A) = 75 db (A). available in preparation 2 option Note: Using sounders with a sound pressure level of 120 db (A) can lead to hearing damage. People must not be permitted to stay in the near vicinity of the sounder. All specifi ed sound pressure levels are based on a measurement distance of 1 m, provided that nothing different is specifi ed. Further technical information can be found on our website at www.pfannenberg.com 13

INTRODUCTION ALL VISUAL-AUDIBLE SIGNALING DEVICES AT A GLANCE Type Maximum covering distance for a 65 db ambient noise level in in metres (m) 1 Sound pressure level (tone) / Light power Protection Dimensions system (HxWxD) mm 2.5 5 25 75 150 MED GL Approvals / Standards GOST UL EN 54-3 VdS EN 54-23 Page P 22 DBF 80 db (A) @ 10 cm IP 40 Ø 29 x 52 153 SON 4 SON 4L 100 db (A) 0.25 J 100 db (A) IP 56 86 x 86 x AC: 120 DC: 102 154 NEW PY X-MA-05 PY X-MA-10 100 db (A) 5 J 100 db (A) 10 J IP 66 IK 08 134.2 x 166 x 114 156 DSF 5 DSF 10 105 db (A) 13 J 110 db (A) 13 J IP 66 IP 67 263.5 x 133.5 x 143 158 2 PA X 1-05 100 db (A) 5 J IP 66 IK 08 172.4 x 109.5 x 80.6 2 160 PA X 5-05 PA X 5-10 105 db (A) 5 J 105 db (A) 10 J IP 66 IK 08 215 x 163.4 x 132 2 2 160 PA X 10-10 PA X 10-15 110 db (A) 10 J 110 db (A) 15 J IP 66 IK 08 270 x 214 x 156 2 2 162 PA X 20-10 PA X 20-15 120 db (A) 10 J 120 db (A) 15 J IP 66 IK 08 270 x 214 x 181 2 2 162 1 The specifi cation for the alarm signal reception range assumes an existing ambient noise level of 65 db (A). In accordance with applicable regulations, the calculated alarm range for the sound level 65 db (A) was given + 10 db (A) = 75 db (A). available in preparation 2 option Note: Using sounders with a sound pressure level of 120 db (A) can lead to hearing damage. People must not be permitted to stay in the near vicinity of the sounder. All specifi ed sound pressure levels are based on a measurement distance of 1 m, provided that nothing different is specifi ed. 14 www.pfannenberg.com

ALL SIGNAL TOWERS AT A GLANCE Overviews Type Mounting variations Operation modes Light intensity / Sound pressure level Protection system Approvals / Standards GL GOST UL EN 54-3 VdS Page SIGNAL TOWERS Ø 54 MM continuous light 7 W BR 50 stand mounting tube mounting direct mounting blinking light fl ashing light 1.5 Hz 0.6 J / 1 J IP 54 (IP 65) 2 170 sounder 85 db (A) SIGNAL TOWERS Ø 35 MM BR 35 stand mounting plinth mounting tube mounting panel mounting continuous light sounder AC: 3 W DC: 4 W 75 db (A) IP 54 177 available in preparation 2 option www.pss-pfannenberg.com Use our PSS Software Tool for easy configuration of the signal tower according to your individual requirements Further information can be found on the Internet: www.pfannenberg.com www.pfannenberg-spareparts.com Keep up to date. Subscribe to our newsletter now: newsletter.pfannenberg.com Further technical information can be found on our website at www.pfannenberg.com 15

INTRODUCTION ALL EX SIGNALING DEVICES AT A GLANCE Type Suitable for use in zones Maximum covering distance as per EN 54-23 in metres (m) 1 Light intensity/ Sound pressure level Protection system Approvals / Standards GL GOST UL 0 1 2 20 21 22 5 25 50 100 125 VdS VISUAL SIGNALING DEVICES EN 54-3 IEC Page Quadro F12-3G/3D 7.5 J IP 66 IK 08 192 Quadro-LED Flex-3G/3D 9 cd IP 66 IK 08 194 BR 50-LED 3G/3D IP 65 196 CWB-ATEX 5 J IP 66 198 BExBG 15 15 J BExBG 10 BExBG 05 10 J 5 J IP 66 IP 67 200 BExBG L1 9 cd 202 IS-mB1 6 cd IP 65 204 AUDIBLE SIGNALING DEVICES SOUNDERS DS 10 3G/3D DS 5 3G/3D 110 db (A) 105 db (A) IP 66 IP 67 206 2 BExS 120 d/e 117 db (A) 2 BExDS 120 d/e IP 66 IP 67 2 BExS 110 d/e 110 db (A) 2 BExDS 110 d/e 2 208 2 210 IS-A105N 105 db (A) IP 66 212 IS-mA1 100 db (A) IP 65 214 available in preparation 2 only d version 16 www.pfannenberg.com

Overviews Type Suitable for use in zones Maximum covering distance for a 65 db ambient noise level in metres (m) 1 Sound pressure level / Light intensity Protection system Approvals / Standards GL GOST UL 0 1 2 20 21 22 5 25 50 100 125 VdS AUDIBLE SIGNALING DEVICES LOUDSPEAKERS EN 54-3 IEC Page BExL 25 d/e BExL 15 d/e 117 db (A) 113 db (A) IP 66 IP 67 216 COMBINED VISUAL-AUDIBLE SIGNALING DEVICES BExCS 110-05D 110 db (A) 5 J 218 BExDCS 110-05D IP 67 BExCL 15-05D 113 db (A) 5 J 220 IS-mC1 100 db (A) / 6 cd IP 65 222 ACCESSORIES Zener barriers 224 1 The specifi cation for the alarm signal reception range assumes an existing ambient noise level of 65 db (A). In accordance with applicable regulations, the calculated alarm range for the sound level 65 db (A) was given + 10 db (A) = 75 db (A). available in preparation Note: Using sounders with a sound pressure level of 120 db (A) can lead to hearing damage. People must not be permitted to stay in the near vicinity of the sounder. All specifi ed sound pressure levels are based on a measurement distance of 1 m, provided that nothing different is specifi ed. Further information can be found on the Internet: www.pfannenberg.com www.pfannenberg-spareparts.com Keep up to date. Subscribe to our newsletter now: newsletter.pfannenberg.com Further technical information can be found on our website at www.pfannenberg.com 17

INTRODUCTION 10 AN EXTENDED WARRANTY FOR SIGNALING DEVICES YEARS WORLDWIDE WARRANTY Over 50 years ago Pfannenberg invented the first industrial flashing light. Today Pfannenberg is still your single source supplier for signaling technology regardless of the application. THE FOLLOWING SIGNALING TECHNOLOGY PRODUCT SERIES ARE NOW BACKED BY A 10 YEAR WARRANTY. Flashing Sounders and Sounders Flashing Lights PATROL series PYRA series High Intensity Flashing & LED Lights Die-cast Aluminium Sounders Quadro series DS series EN 54-3 18 www.pfannenberg.com EN 54-23 VdS SIL C US LISTED PL

PSS PFANNENBERG SIZING SOFTWARE THE SOFTWARE The Pfannenberg Sizing Software is the free and easy tool we developed to help you determine your cooling requirements. You can easily get a recommendation for the correct device components needed in your project. SIGNALING PROJECTS PSS helps you choose the best sounder or visual signaling devices according to your project specifi cations. Just defi ne the kind of device you need (visual, audible or combined) and some technical data, the PSS tool will do the rest. THERMAL MANAGEMENT PROJECTS You just need to fi ll in the technical data available for your project (panel dimensions, temperature, heat dissipation, etc) and the software will propose you the best cooling solution such as cooling units, heat exchangers, fi lterfans or chillers. Visit our website and try it now! Download it Online version Free app for tablet Order a cd version www.pss-pfannenberg.com info@pfannenberg.com Further technical information can be found on our website at www.pfannenberg.com 19

INTRODUCTION THE NEW PRODUCT STANDARD EN 54-23 EN 54-23 CERTIFIED FLASHING LIGHTS FROM PFANNENBERG In most European countries EN 54-23 will take effect in 2013 for visual signaling devices. Because of that all visual signaling devices will lose their certifi cations and may no longer be used for new installations. In particular, all visual signaling devices which have not conformed to EN 54-23 by 1. March 2013 lose VdS approval. Pfannenberg is the fi rst manufacturer to offer beacons that are certifi ed according to both the new standard and VdS: The fl ashing light PY X-S-05 and the combined visual-audible device PA X 1-05 are available in the standardized lens colors red and clear. He mounting position of the fl ashing light is freely selectable. This allows a fl exible installation and reduces signifi cantly the number of required signaling devices. YOUR BENEFITS BY USING FLASHING LIGHTS CERTIFIED WITH EN 54-23: Planning dependability in project management Guaranteed compliant fi re alarm systems Minimisation of liability risk For system integrators and manufacturer of fi re alarm systems: Security regarding system requirements and compatibility For building operators: Possible reduction in insurance premium THE REQUIREMENTS OF EN 54-23 IN PRACTICE Illumination intensity An illumination intensity of min. 0.4 lux (lm/m²) is required over the entire coverage volume, i.e. the space in which the alarm signal is to be effective (e.g. production facilities). Light color The visual signaling device must emit white or red fl ashing light. Flash rate The fl ash rate must be between 0.5 Hz and 2 Hz. Coverage volume Visual alarm devices must meet the requirements for the coveragevolume in at least one of the following three categories: ceiling mounted signaling device C; wall mounted signaling device W; or O for signaling devices for which the mounting position is freely selectable. In order to achieve this, the light intensity of the signaling device must be signifi cantly higher than those used in the past. This also entails an increased power consumption. 20 www.pfannenberg.com

MOUNTING CATEGORIES Technology Ceiling mounted Devices from category C are described with the specifi cation C-x-y. x stands for the measured maximum installation height in meters (m) at which the signaling device may be placed. Whereas y specifi es the diameter of the cylindrical coverage volume. Besides the specifi cation of the cylindrical signaling space the devices are only classifi ed for heights up to 3 to 6 or up to 9 m. Example: C-3-7.5. stands for a ceiling mounted signaling device with a cylindrical coverage volume of 7.5 m diameter and a maximum mounting height of 3 m. y x Wall mounted Category W devices are described with W-x-y. x stands for the maximum height of the signaling device on the wall specifi ed in meters (m) with a minimum installation height of 2.4 m. y describes the square base area of the cuboid coverage volume. Example: W-2,4-8 stands for a wall mounted signaling device with a cuboid coverage volume of 2.4 m x 8 m x 8 m, if mounted at a height of 2.4. y y x Open mounting position For category O devices the shape of the coverage volume and the mounting position of the signaling device is open. This means there are no restrictions on the formation of the coverage volume. From the user s perspective this is the most fl exible and economical solution, because there is no need to differentiate between ceiling and wall installation (minimisation of inventory) and the greatest possible coverage volume of the signaling device is achieved. Pfannenberg provides only EN 54-23 flashing lights that are certified for category O. CALCULATION As an example, a room of 20 m length, 8 m width and 3 m height is to be signalled. Planning with the following three devices is compared: The Pfannenberg PYRA fl ashing light (category O) with the following coverage volume 11.1 m x 8.4 m x 6.3 m The same device, however if it were only approved for ceiling-mounting, (see advantages of cat. O), coverage volume C-6-10.6. A comparable device of category C-3-7.5. On account of the specifi ed coverage volumes, the following quantities for visual signaling devices arise: 8.4 m max. 6.3 m 10.6 7.5 6 3 11.1 m 11.1 m PYRA (Cat. O) 11.1 x 8.4 m PYRA (Cat. C) C-6-10.6 VADs for ceiling mounted position (Cat. C) C-3-7.5 Further technical information can be found on our website at www.pfannenberg.com 21

INTRODUCTION CONCLUSION AND RECOMMENDATION Category O devices are the most flexible solution The signaling device can be optionally mounted on the ceiling, wall or another position, whereas category C and W devices are only allowed to be mounted according to their classifi cation. Category O devices are the most economical solution Only one signaling device is required for all mounting positions. This avoids having to keep double stock. No restriction with the mounting height - devices with the identifi er C-3-y are not approved for ceiling heights of 3.2 m for example and a device of category C-6-y has to be taken, which would be far too oversized for this application. The shape of a cylinder is generally not compatible with the shape of rooms. The actual coverage volume of the device is firstly reduced to a cylinder shape. In order to then be in a position to use the shape of the cylinder and to make planning possible, it is necessary to further reduce the coverage volume to the largest possible quadratic area. This automatically requires the use of a larger number of signaling devices in order to ensure alarming of the room. The shape requirement with quadratic base area for category W devices means that the actual coverage volume that the device could cover is reduces in certain places. As a result of the artifi cially reduced coverage volume, an increased number of devices is necessary. Category O devices are subject to no restrictions, so the formation of the largest possible coverage volume in the form of a freely selectable cuboid is possible. y F F= y2 2 THE CONSEQUENCES FROM PLANNING TO PUTTING INTO OPERATION for planners and specifiers modifi cation of the contractual basis modifi cation of the tendering text / items consideration in all current and future projects information for the ordering customer testing and acceptance of the visual signaling device for fire detection technology experts defi ne the basis for testing/demand for certifi cates testing the function of the visual signaling device and matching with data sheet for system integrators creation of a system approval according to EN 54-13 implementation of EN 54-23 approved visual signaling devices in the system for installors and specialist companies consideration in all current and future projects, inform on erroneous items in the tender, possibly revision information for the ordering customer modifi cation of the offers for building operators review of the contractual documents information to the planning company 22 www.pfannenberg.com

PROTECTION SYSTEM Technology IP IP PROTECTION SYSTEM The protection system for devices in accordance with DIN EN 60529 (DIN VDE 0470 IEC 60529) indicates suitability for various environmental conditions. 1 st digit Protection against foreign particles 2 nd digit Protection against water 0 no protection 0 no protection 1 large foreign matter (Ø from 50 mm) 1 vertically dripping water 2 medium-sized foreign matter (Ø from 12.5 mm, length up to 80 mm) 2 water dripping at an angle (up to 15 ) 3 small foreign matter (Ø from 2.5 mm) 3 falling spray water up to 60 from the vertical 4 foreign matter in the form of grains (Ø from 1 mm) 4 spray water from all sides 5 dust deposits in non-damaging quantities 4k spray water from all sides under increased pressure; applies only to road vehicles 6 no entry of dust 5 Water stream (jets) from any angle 6 strong water stream (jets) (fl ooding) strong water stream (jets) under increased pressure 6k (fl ooding); applies only to road vehicles 7 temporary immersion 8 permanent immersion high pressure water/steam cleaning; applies only to road 9k vehicles COMPARISON OF NEMA AND IEC PROTECTION SYSTEMS CLASSIFICATION The National Electrical Manufacturers Association (NEMA) sets standards and norms in the USA. NEMA protection system Protection IEC protection system 1 falling dirt IP 10 2 dripping water and falling dirt IP 11 3 wind-blown dust, rain and hail; no damage due to external ice formation IP 54 3 R rain and hail; no damage due to external ice formation IP 14 3 S wind-blown dust, rain and hail; also usable in the case of external ice formation IP 54 4 wind-blown dust, rain, spray water and water streams; no damage due to external ice formation IP 56 4 X wind-blown dust, rain, spray water and water streams; no damage due to external ice formation, rotection against corrosion 5 dust, falling dirt, dripping non-corrosive fl uids IP 52 6 water streams, temporary immersion; no damage due to external ice formation IP 67 6 P water streams, longer periods of immersion IP 67 12 and 12 K swirling dust, falling dirt, dripping non-corrosive fl uids IP 52 13 dust, spray water, oil, non-corrosive fl uids IP 54 Please note: IP and NEMA codes are not directly, but rather only approximately, comparable Further technical information can be found on our website at www.pfannenberg.com 23

INTRODUCTION SIL/PL-COMPLIANT SIGNALING TECHNOLOGY With the new Machinery Directive, which will apply Europe-wide from 2010 onwards, there will be a change in the requirements for machine safety. More than ever before, certification and market opportunities depend on safety-related products. The new SIL/PL-conform alarm devices from Pfannenberg give machine and plant manufacturers more planning safety; the acceptance process is simplified and accelerated. The goal of the new standards is risk minimization in the operation of machines to avoid harm to persons. Naturally, the availability of the machine and plant is also increased as a result, which on the other hand has a positive effect on the TCO-evaluation, with immediate effect, probability considerations will henceforth also play a role in the determination of component safety. SIL (Safety Integrity Level) and PL (Performance Level) have become central terms in the categorisation of risks and safety. In many cases, purely constructional measures on the machines don t go far enough to minimize risk. In order to keep the existing residual risk of a machine or a plant low, reliable alarms are required, which draw attention to hazards through visual or acoustic warning signals. For example, as a start-up warning or in muting operation, while protective functions have been disabled. Alerting of personnel in case of gas or chemical leaks requires 100% operational reliability of the signaling devices. SAFETY INSTRUMENTED SYSTEM SIS (SAFETY LOOP) Sensor Logic Actor Detecting Evaluating Alerting CAUSES OF WORK ACCIDENTS AT MACHINES The statistics on the cause of work accidents show a clear picture: Human error is responsible for half of all accidents. These have to be reduced further by means of secure alarm raising. 12 % 11 % 1% Human behavior Organisational reasons Technical reasons Workplace Psychological causes 26 % 50 % Diagram from safety-network.de 24 www.pfannenberg.com

Further information can be found in the download area under Academy at www.pfannenberg.com! Technology THE NEW MACHINERY DIRECTIVE 2006/42/EC The transition period for the new Machinery Directive 2006/42/EC ends on 1 January 2010. It has already been signed on 17 May 2006 and published on 9 June 2006 in the offi cial gazette of the European Union (Abl. L 157). Two new safety standards are coming into effect with the Machinery Directive. Firstly, DIN EN ISO 13849-1, which replaces the standard DIN EN 954-1 of the old Machinery Directive 98/37/EG. The other is DIN EN 62061. The goal of these new safety standards is risk minimization in the operation of machines. Therefore, the requirements with regard to certifi cation of products for manufacturers of plants and machines were made more stringent. Now, probability considerations are also taken as inputs in determining the safety of components. Planning security and market opportunities of manufacturers of machines and plants are thus supported by a safety-related visual and acoustic alarm system from Pfannenberg. SIL/PL GRADATION Allocation of the level after a risk analysis. What is calculated here is the probability of failure of the system. Average probability of a dangerous failure per hour. PFH D Performance Level Safety Integrity Level DIN EN ISO 13849-1 DIN EN 62061 10-4 10-5 3 10-5 10-6 10-7 10-8 10-9 PL a --- PL b PL c SIL 1 PL d SIL 2 PL e SIL 3 --- SIL 4 SAFETY FROM THE BEGINNING: SIL/PL-CONFORM SIGNALING BY PFANNENBERG As with all chains, the safety chain is only as strong as its weakest link! This integral view of safety functions is the foundation of the respective norms from process and systems engineering, as well as mechanical engineering. Visual and audible warning devices are, as the defi nition clearly states, devices, which warn people about acute dangers. Therefore, these need to be implemented into safety chains of many applications. This is the link of the change that reaches people! The integration of visual and audible warning devices in the safety chain is required by norm in many applications. For example, machines that are hard to view as a whole must be equipped with start-up alarms according to SIL 1 and respectively, PLc. Machines are defi ned as hard to view when they have a length of 7 m or more. Further applications for SIL-capable signaling devices are, amongst others - muting indication (i.e. during safety function bypassed by the safety-related controller) - excess rotation speed warning - machine stop delay warning Applications in process and plant safety (Control Technology/PCS), e.g. in case of - leaks / gas warning - high-pressure / overfilling Functional safety in process automation normally based on the statutory order of hazardous incidents. The statutory order refers to the design of safety-relevant devices in EN 61508 and EN 61511 respectively. They defi ne the safety steps which describe the measures to control risks of equipment. Among others, the VDMA (German Association of Machinery Manufacturers) and the ZVEI (German Electrical and Electronics Industry Association) inform intensively about the implementation of safety standards. SIL compliant signaling devices by Pfannenberg can be found on pages 100, 102 and 144. Further technical information can be found on our website at www.pfannenberg.com 25

INTRODUCTION VISUAL SIGNALING DEVICES BY PFANNENBERG Our comprehensive range includes: xenon fl ashing lights halogen blinking and continuous lights continuous lights with fi lament lamps LED multifunction lights rotating mirror lights panel mount blinking and continuous indicators combination lights traffi c light lights signal towers visual signaling devices for the Ex area SIL conform visual signaling devices obstacle lights A large proportion of our signaling devices are provided with the following features, which make their use in special applications possible, such as in safety-relevant applications: synchronisation of several lights redundant structure integrated function monitoring limitation of initial current BASIC PRINCIPLES OF OPTICS Light moves as electromagnetic wave, which are distinguished from one another by their wavelength. The wavelengths of that part of the electromagnetic spectrum, which are visible to the human eye lie between 380 nm and 780 nm and are called the visible spectrum. The visible spectrum itself is in turn made up of different electromagnetic waves that generate the perception of different colours in our eyes. The limits of the visible spectrum are represented by infrared and ultra-violet light. The spectrum visible to the human eye (light) Ultra-violet Infrared 400 nm 450 nm 500 nm 550 nm 600 nm 650 nm 700 nm Cosmic Gamma- hard, medium, soft UV- Infrared Terrahertz Radar UHF UKW Medium wave high, medium, low radiation radiation X-ray radiation C/B/A radiation radiation Microwave oven VHF Short wave Long wave frequency ultra-violet Microwaves Radio AC currents i fm 1 pm 1 Å 1 nm 1 µm 1 mm 1 cm 1 m 1 km 1 Mm 10-15 10-14 10-13 10-12 10-11 10-10 10-9 10-8 10-7 10-6 10-5 10-4 10-3 10-2 10-1 10 0 10 1 10 2 10 3 10 4 10 5 10 6 10 7 10 23 10 22 10 21 10 20 10 19 10 18 10 17 10 16 10 15 10 14 10 13 10 12 10 11 10 10 10 9 10 8 10 7 10 6 10 5 10 4 10 3 10 2 1 Zetta-Hz 1 Exa-Hz 1 Peta-Hz 1 Terra-Hz 1 Giga-Hz 1 Mega-Hz 1 Kilo-Hz 26 www.pfannenberg.com

TYPES OF LIGHT GENERATION There are several ways of generating light in signaling technology. Technology Filament lamp In the fi lament lamp, an electric conductor (fi lament) is heated up by an electric current to the point where it glows and is perceived as a source of light. In order to protect the tungsten fi lament against the oxygen in the air and to prolong its service life, it is shielded by a vacuum in a glass bulb. The power of a fi lament lamp is expressed in Watts and is calculated as follows: Power (P) = Voltage (U) Current (I) Although this type of light generation is still being used, it is being displaced more and more in the market due to its very limited service life and poor light production. Halogen lamp The glass bulb of a halogen lamp is fi lled with halogen bromine, which virtually doubles the service life of this lamp compared to the normal fi lament lamp, as well as increases the light production and allows the bulb to be operated at higher temperatures. The light output of a halogen lamp remains virtually constant throughout its service life. LED Lamp A light-emitting diode is an electronic semiconductor. If current flows through the diode in the conducting direction, it emits light. The light energy is released in the form of photons. Light diodes are not temperature radiators. They are insensitive to impacts and vibration and consume little current. The service life of an LED is described as the time period over which the light yield decreases to half of its initial value and is usually more than 50,000 hours. Since LEDs are available in all normal colours, the use of colour fi lters is not necessary. LED lamps are available in exchangeable versions with a fi tting or as permanently installed LED arrays. Flash capacitor Xenon fl ash tube Electronic clock Power supply and charging circuit Gas discharge lamps The energy stored in the capacitor discharges in the gas-filled glass tube and forms a light arc. Xenon gas is predominantly used in signal technology. The flash energy per individual flash is calculated according to the following equation: E = 1/2 C U 2 E = Flash energy (Joules) C = Capacity of fl ash capacitor (Farads) U = Charging voltage (Volts) The electrode material is subjected to a very large load during the discharge. Although very hard metals such as tungsten are used for the electrode, a certain amount of the metal is removed depending on the load and is deposited as a dark fi lm on the inside of the fl ash tube. The advantage of this technology is the high signaling effect due to the concentrated light pulse. Further technical information can be found on our website at www.pfannenberg.com 27

INTRODUCTION XENON TECHNOLOGY VERSUS LED TECHNOLOGY Currently, the LED technology is the buzz in the area of generating light. In signaling technology, LED is being used increasingly. Thereby, LED is connected with positive characteristics such as energy effi ciency, life span and insensitivity to mechanical infl uences, which cancel out the negative side, the price. Visual signaling technology must cover various application in three areas: ALARM WARNING INDICATION in which there are different requirements, e.g. special visual appearance, for the products. While the positive characteristics of LED technology come to use almost to 100% in the area of Informing, in the areas Warning and Alarm, the advantages of the LED technology are scarcely considered. When taking the area Alarm into consideration, the perceptibility is in the foreground in order to convey the signal and therewith, the urgency of the alarm to the observer. Here, devices based on Xenon technology exhibit distinct advantages, e.g. the differential luminance, which can be ascribed to the formation of the light impulse. A Xenon fl ashing light creates a very short (approx. 250 ms), yet very intense impulse with a peak value of well over 100 000 cd, which cannot be produced by means of LED technology. Typical curve progressions are depicted in fi gures 1 and 2. It is clearly visible that the light intensity of the LEDs only has a fl at progression, in contrast to the Xenon fl ash tubes. Both lights have almost the same effective luminous intensity. When comparing the bottom line of the expense of energy for both technologies, the LED is also, in this aspect, not advantageous. The effective power consumption of a Xenon fl ashing light is lower when compared to a LED fl ashing light that has almost the same effective luminous intensity as the Xenon light. Furthermore, LED lights with the same effective luminous intensity as compared to Xenon lights are signifi cantly more expensive. I.e. not only are the operating costs, but also the acquisition costs in favor of the Xenon technology. Luminous intensity / course of time of a Xenon fl ashing light [cd] Light intensity [cd] 100 000 80 000 60 000 40 000 20 000 0 0 250 500 750 1 000 1 250 Figure 1 Time Zeit [µs] Luminous intensity / course of time of a LED fl ashing light [cd] Light intensity [cd] 400 300 200 100 0 0 20 000 40 000 60 000 80 000 100 000 120 000 Figure 2 Time [µs] Another advantage of Xenon lights are the emission characteristics. Whilst in LED technology, these only produce an approximate omni-directional characteristic through the arrangement of the LEDs in the casing, the Xenon technology has a radiating point of light that provides for this from the get go. The emission characteristics are identical in all directions and thus, no optical gaps are created in all directions of light. The duty cycle is a positive LED characteristic that offers an advantage over Xenon technology. Yet when you take into consideration that special alarm devices are only needed and activated in dangerous situations, the life span of the lights is not crucial criteria. Pfannenberg Xenon fl ashing lights have a life span of a minimum 8 million fl ashes; this is adequate to warn of dangerous situations, in most cases, for a period of at least 20 years. All Xenon fl ashing light tubes are secured by means of an additional steel rod in Pfannenberg products so that the mechanical infl uences (shock/vibration) are reduced to a minimum. In applications where the signaling devices are not just used frequently but also function as a permanent beacon, the advantage of LED-based devices is obvious: The duty cycle and low power consumption cannot be surpassed. 28 www.pfannenberg.com

THE MOST IMPORTANT LIGHT VARIABLES IN SIGNALING TECHNOLOGY ARE: Technology light intensity luminous fl ux illumination intensity Light intensity is measured in Candela [cd]. The light intensity is the radiation power of a light source per dihedral angle, weighted with the spectral sensitivity of the eye. The directional dependence of the luminous fl ux is represented. This is particularly important in signal technology, since it is not about illuminating a room, but rather about the directed transmission of light to the observer. light intensity [cd] = luminous flux [lm] / dihedral angle [sr] For example, the light intensity of a household candle is around 1 cd. Luminous fluxφ is expressed in Lumen [lm]. The luminous fl ux is a measure of the entire visible radiation that is radiated in all directions from a source of light and, as opposed to light intensity, is not directionally dependent. Illumination intensity is expressed in Lux [lx]. The illumination intensity describes the amount of the luminous fl ux that strikes a given area. It is the quotient of luminous fl ux and area. illumination intensity [lx] = luminous flux [lm] / area A (m 2 ) The illumination intensity is inversely proportional to the square of the distance. A doubling of the distance therefore results in the illumination intensity being reduced to one quarter. Light intensity Luminous fl ux Light density Illumination intensity Further technical information can be found on our website at www.pfannenberg.com 29

INTRODUCTION TYPES OF BEACON Visual signaling takes place by means of colour, light intensity and lighting duration. Four types of beacons with different signaling effects are essentially offered in signal technology; Continuous lights lowest signaling effect The light intensity of the continuous light changes with the power of the lamp and the use of different colours and types of lenses. This type of beacon is normally used to display a status and serves to a lesser extent as a means of an alarm. Blinking lights increased signaling effect The observer s attention is increased by means of switching the lamp on and off with a blinking frequency of normally 1 to 2 Hz. This type of beacon is used, for example, as a warning signal. Rotating mirror lights high signaling effect A rotating light cone is generated by means of diverting the light using the internal rotating mirror. Higher attention is gained at faster rotary speeds. Smooth lenses are used for these beacons in order to exploit the light effect to its fullest and to avoid scattering effects. As opposed to fl ashing beacons, the dazzling effect is reduced with rotating mirror beacons. Flashing lights highest signaling effect The charged capacitor discharges its energy into the gas-fi lled glass tube and forms a light arc. This very short and very intensive light effect generates the highest signal attention. Among other things, this type of beacon is used as a top priority alarm. MEANING OF THE COLOURS IN VISUAL SIGNALING The signal colours red, amber, yellow, green, blue and clear are mainly used in signal technology. Different lamp colours convey different messages to the observer in accordance with EN 60078, EN 981 and DIN VDE 0199. Colour Process status (as per IEC 73) Process data (as per IEC 73) Meaning / message category Purpose User reaction (as per DIN VDE 0199) Example application red emergency limit value exceeded danger abnormal status act immediately urgent rescue or protection measure emergency alarm stop prohibited failure immediate reaction stop sign prohibiting sign emergency stop devices yellow / amber abnormal warning limit reached caution be prepared act if necessary attention required change of status intervention monitor and/or intervene indication of dangers, such as: fi re, explosion, radiation, chemical infl u- ences, obstructions etc. green normal within normal range everything ok normal status safe no danger danger is pastr fi rst aid return to normal process continue no action required identifi cation of escape routes and emergency exits fi rst aid and rescue stations blue specifi ed meaning specifi ed meaning display of necessity for specifi ed action command sign notice machine-specifi c action protection extraordinary attention safety-relevant regulation or precaution with priority specifi ed action obligation to wear personal protective equipment location of a telephone etc. white / clear other neutral neutral not assigned any particular meaning 30 www.pfannenberg.com

LIGHT PERMEABILITY OF COLOURED LENSES Depending on the respective light source and the various lens colours, the following percentage of light typically penetrates through: Technology Colour Filament lamp Halogen lamp Xenon lamp clear 100% 100% 100% yellow 95% 94% 93% amber 70% 70% 70% red 17% 27% 23% green 12% 15 % 25% blue 15% 20% 24% This reduction in the light intensity must be taken into consideration when selecting the right signaling device! Due to the narrow spectrum of LED light sources, only a small reduction in the light is to be expected if the colour of the lens corresponds to the colour of the LED. PLANNING VISUAL SIGNALING EN 54-23 for Europe and NFPA 72 for the USA offer a tangible basis for the design of visual signaling: The table below is based on the following calculation equation and can also be used for other room sizes or distances: d = I Eff / E d is the distance between the observer and the alarm device in metres [m] I eff is the effective light intensity in Candela [cd] E is the illumination intensity in Lux [lx] The illumination intensity E must not fall below 0.4 lx at any place within the defi ned signal reception area. Examples of the signaling devices to be used, depending on the room size maximum room size (m x m) minimum light intensity (effective intensity [cd]) 1 light/room 2 lights/room 3 lights/room (synchronised) 6 x 6 15 not permitted not permitted 12 x 12 60 30 15 18 x 18 135 95 30 24 x 24 240 135 60 Due to the complexity when considering visual signaling, we recommend checking the effi ciency of the alarm on-site by using a representative group of people. In doing so, a worst case scenario must always be performed based on the environmental conditions. Further technical information can be found on our website at www.pfannenberg.com 31

INTRODUCTION PERCEPTION OF THE BRIGHTNESS OF LIGHT FOR WARNINGS AND ALARMS A few tips to assist you in selecting the right visual signaling devices: Doubling the distance reduces the light power by 75% to 1/4 of its strength. If the distance is quadrupled, the light power is reduced to 1/16. Visual alarms are ideal when there is a direct (unobstructed) line of sight between the beacon and the observer. Refl ected light can be perceived inadequately. In an alarm area (dangerous condition, immediate action), the beacon will also be perceived without direct visual contact provided that the light intensity of the alarm device is 10 times brighter than the ambient light. In a warning area (critical condition, intervene), the signal will be perceived adequately via direct visual contact or refl ection provided that the light intensity of the warning device is 5 times brighter than the ambient light. OPTICAL AND ELECTRONIC MONITORING Monitoring of visual alarm devices plays a very important role, especially in the case of safety-relevant applications. Monitoring is offered in two different technical versions. One method is to monitor the correct function of a fl ashing light by opto-electronic means. The light fl ash from the fl ashing light is fed via an optical fi bre to a phototransistor, which converts the optical impulse to an electrical impulse. The optical fi bre is located in the housing of the fl ashing light and directed downwards, which excludes false triggering due to the effect of daylight. Additionally, any fl ashing light with a 1 Hz fl ash rate can be retrofi tted with an external fl ash monitor. The downstream circuitry evaluates the pulse and its regular repetition. As soon as the operating voltage is applied, the evaluation relay closes the error contact. If the operating voltage fails, the relay opens immediately. This method of operation represents the fail-safe normally-closed circuit function and guarantees an alarm even if the operating voltage fails. On the other hand, the error message contact serves the continuative alarming, e.g. in an error message line, or the direct blocking of further machine processes. It is possible to relay the error alarm as a normally-closed function. The second method of electronic monitoring is to integrate a fl ash monitor in the processor of the fl ashing beacon. In this case the regular charging and discharging of the fl ashing beacon capacitor is monitored. If one status is not present, an error message is relayed via a fl oating, normally-closed contact. INRUSH CURRENT LIMITATION Visual alarm devices can draw a greatly increased initial current for a very short period of time. This is due to the circuit-related input capacity. This can lead an overload of the relay contacts at the moment when power is turned on and to the premature triggering of overcurrent circuit breakers. Example of the current curve with and without a soft-start module î up to 12 A without SSM For special requirements, Pfannenberg can supply you with visual alarm devices that are factory fi tted with an initial current limiter. Pfannenberg also offers external current limiting modules, so-called soft-start modules (SSM), for retrofi tting or supplementing visual signaling devices. Amps with SSM 0 1 2 3 4 5 6 7 8 9 10 11 12 ms 0 1 2 3 4 5 6 7 8 9 10 11 12 Current limitation 0.7 1.5 A 32 www.pfannenberg.com

AUDIBLE SIGNALING DEVICES BY PFANNENBERG Technology Our comprehensive range includes: electronic multi-tone sounders electronic multi-tone sirens and horns programmable voice sounders (also in synchronised versions) combined signaling devices buzzers and panel mounted buzzers audible signaling devices for the Ex area SIL conform audible signaling devices BASIC PRINCIPLES OF ACOUSTICS A source of sound causes the air to oscillate, resulting in alternating compression and relaxation of the air. This pressure wave propagates itself in the form of a wave and causes the eardrum to oscillate, triggering the process of hearing. The sound pressure of oscillation is measured in microbars (µbar). The number of oscillations per second is called the frequency. Its unit of measurement is Hertz (Hz). DIFFERENT TYPES OF SOUND a harmonic oscillation produces a tone a sound represents a mixture of tones noise is the name given to a mixture of numerous tones, rapidly changing frequencies and rapidly changing sound volumes a bang is produced by a sudden beginning of a mechanical oscillation of very short duration and great loudness Sound pressure p high tone: many p low tone: few oscillations per second Sound pressure p Impulse (hammer) Sound pressure p Machine noise Time p p Time p Time Sound pressure p quiet tone p loud tone Sound pressure p Tone Sound pressure Sound p Time p Time Time Properties of sound waves: the number of vibrations per unit of time = frequency range of the oscillation = amplitude Further technical information can be found on our website at www.pfannenberg.com 33

INTRODUCTION FREQUENCY RANGE AND SOUND PRESSURE LEVEL The range of human hearing is from 20 to 20,000 Hz. Deeper sounds (infrasound) and higher sounds (ultrasound) cannot be heard. The human ear is most sensitive to sound between 500 Hz and 3 khz. With regard to volume, a sound pressure of 2/10,000 = 0.0002 µbar is just barely audible. This limit value is called hearing threshold pressure. A sound pressure of 200 µbar and above causes pain. This is known as the pain threshold. In order to make the hearing range more manageable in terms of numbers, the ratio of the actual measured sound pressure to the hearing threshold pressure is converted to a logarithm. This logarithmic relationship is known as the sound pressure level and is expressed in decibels (db). The equation is: Lp= 20 x log measured sound pressure in µbar db hearing threshold pressure in µbar 100 000 000 µpa 10 000 000 µpa 1 000 000 µpa 100 000 µpa 10 000 µpa 1 000 µpa 100 µpa 140 db (A) 130 db (A) 120 db (A) 110 db (A) 100 db (A) 90 db (A) 80 db (A) 70 db (A) 60 db (A) 50 db (A) 40 db (A) 30 db (A) 20 db (A) 10 db (A) 20 µpa 0 db (A) BASIC PRINCIPLES OF ACOUSTIC AUDIBILITY The loudness of a sounder is expressed in db (A) and measured at a distance of 1 metre (USA 10 feet). The smallest increase in the sound level that the human ear can detect is 3 db. An increase of 6 db is equivalent to a doubling of the sound pressure. An increase of around 10 db is perceived as being twice as loud. Reduction in the sound pressure level in relation to the distance between the sounder and the listener s ear 0 Lower frequencies (at the same sound level) are perceived to be quieter. This is all the more pronounced at lower sound levels. Alarm signals can be better heard when the difference between the frequency of the ambient noise and that of the sounder is greater. Interfering factors are, for example, damping, fog, obstructions, wind speed and direction, rain and air humidity. A doubling of the distance to the source of the sound is equivalent to a reduction in the sound level of around 6 db, e.g. there is a sound pressure level reduction of 35 db at a distance of 58 m. Sound pressure reduction (db) -10-20 -30 Example -35-40 -50 1 2 4 8 16 32 64 128 256 58 Distance (m) A large number of audio samples of different tones are available at www.pfannenberg.com/support. 34 www.pfannenberg.com

TYPES OF SOUND GENERATION Technology Sound capsule electromagnetic sound generation In the sound capsule, anchors connected to the membrane are premagnetised by a permanent magnet. When a voltage is applied, the membrane is stimulated to oscillate, generating sound waves that are perceived as an audible tone. Despite its relatively simple and compact structure, the sound capsule has a relatively high effi ciency level. For that reason this technology is often used in appliances with small dimensions. Loudspeaker electro-dynamic sound generation The electro-dynamic loudspeaker consists of a membrane connected to a central oscillating coil. This coil is located within the magnetic fi eld of a permanent magnet. If the voltage of the signal to be transmitted is applied to this coil, an alternating electromagnetic fi eld is generated that causes the membrane to move and, hence, to generate sound pressure. Various membranes (smaller or larger, softer or harder) and different coils and permanent magnets are used, depending on the frequency range. Electrodynamic loudspeakers are ideally suited for generating high sound pressure. Horn loudspeaker electro-dynamic sound generation The membrane in a horn loudspeaker acts on a very small space the pressure chamber. The velocity of the air particles is increased in this pressure chamber due to its small cross-sectional size. This principle increases effi ciency considerably in comparison to other designs. Due to the high sound pressure, which can be attained and the high frequency range that can be transmitted, horn loudspeakers are ideal for the transmission of sound in large areas. Horn loudspeakers are usually insensitive to weather and are very robust. Piezo-electric effect At the heart of a piezo loudspeaker is a crystal. When a voltage is applied to this crystal, it deforms as a result and is thus set in motion. Piezo loudspeakers essentially transmit only higher frequency ranges and are not suitable for penetrating through obstructions such as walls. The advantage of these systems lies in their high impedance and, therefore, low power consumption. Further technical information can be found on our website at www.pfannenberg.com 35

INTRODUCTION PLANNING AUDIBLE SIGNALING In order to determine the acoustic alarm, it is important to know the starting value (existing ambient noise level) and the target value to be calculated. According to the EN ISO 7731 standard (replacement for EN 457), a sounder should have a minimum sound level of 65 db (A). Standard Minimum difference to the ambient noise level Application EN ISO 7731 at least 15 db (A) Public areas and workplaces DIN VDE 0833 EN 60849 at least 10 db (A) Fire alarm (in fi re alarm systems) Evacuation signal (in alarm systems) From a required sound level of 110 db (A) upwards, it is recommended to use visual signaling devices in addition to acoustic alarms. Example calculation There are various possibilities of achieving 82 db (A) for an area of 50 x 30 m: 1 x 120 db (A) or 10 x 100 db (A) sounders are required. Sound transmission area of a 100 db (A) sounder in order to achieve 82 db (A) = 200 m 2 Sound transmission area of a 120 db (A) sounder in order to achieve 82 db (A) = 20,000 m 2 100 db (A) 120 db (A) 82 db (A) The type of signaling (number of sounders) used is essentially determined by the geometric properties of the room, the shape of any obstructions and the maximum permissible sound pressure level of the sounder. When using a sounder with, for example, 120 db (A), it must be ensured that people cannot be in the near vicinity of the sounder. If this is not possible, a divided installation should to be chosen. 36 www.pfannenberg.com

THE MEANING OF DIFFERENT TONES Technology Pfannenberg sounders can generate up to 65 different tones. All tones can selected individually and must be adapted to suit the respective environmental conditions. Therefore, some of the pre-installed tones have a predefi ned meaning. Standard 1200 Hz DIN 33404 Acoustic alarm signal for workplaces in cases of fi re, gas, explosion or radiation danger 500 Hz 1s ISO 8201 Emergency evacuation signal 950 Hz 1s 1,5s 1200 Hz NFS 32-001 Fire alarm in France 500 Hz 1s SS 031711 Emergency signal in Sweden 700 Hz 0,25 s duration Dauer 60 60 s s A large number of audio samples of different tones are available at www.pfannenberg.com/support. MONITORING: STANDBY CURRENT There are two ways of monitoring the standby current electronically using a terminal resistor in order to monitor acoustic signaling devices: measurement of the current below the lower nominal voltage limit of the device, or measurement of the standby current by reversing the supply voltage poles INRUSH CURRENT LIMITATION Acoustic alarm devices can draw a strongly increased initial current for a very short period of time. This is caused by the circuit-related input capacity. For special requirements, acoustic alarm devices are available with an initial current limiter. Further technical information can be found on our website at www.pfannenberg.com 37

INTRODUCTION PICTOGRAMS +... C... C Operating temperature range. Highest and lowest temperature values ensured by the technical data. IP 67 Protection system specification according to DIN EN 60529. General information on the protection of electrical equipment against contact, foreign particles and water. Devices with IP 54 can be used outdoors. IK 08 Impact-proof housing. Protection system specifi cation according to DIN EN 50102. SPS I lim t 30 Activation input with opto-coupler 24 V DC / 2 ma. Equipment with inrush current limitation. Optional fl ash rate (standard: 60 fl ashes/min.). Protective cage made of rustproof metal. Active protection against contact and sabotage, plus operation under tough conditions. External fl ash monitoring for visual alarms. The fl ash is detected and monitored via a fi bre-optic cable. In the case of a malfunction, an alarm is given in the form of a normally closed function (fl oating contact). Volume control. For the optimal adaptation of the signal to the surroundings and the avoidance of startled reactions. 3 J r = 20 m Optional brightness, e.g. 3 Joules. External tone selection. For controlling various types of tones in a device. Reception range of the signaling device, within which the signal is adequately perceived. SYNC Synchronous operation of several signaling devices. Light pulses or tones are rendered in absolute synchronisation. Noise level reduction by means of external switch. Light sensor. Automatic adjustment to the ambient light. Acoustic penetration. Excellent acoustic penetration of acoustic obstacles such as walls and doors. EN 54-3 The European standard for the approval of acoustic alarms in fi re protection facilities. EN 54-23 The European standard for the approval of visual alarms in fi re protection facilities. 38 www.pfannenberg.com

APPROVALS AND TEST SYMBOLS Germanischer Lloyd sets standards in technology, quality and safety for shipping and industry. Germanischer Lloyd is additionally a leading certifying body in the fi elds of wind power, environmental protection, the oil and gas industry and building technology. VdS-Zulassung VdS Schadenverhütung GmbH The Verband der Sachversicherer (VdS) [= Association of Material Insurers] tests and certifi es components for facilities dealing with damage prevention. The VdS guidelines contain requirements for components used for protection against fi re and burglary. C US UL LISTED Underwriters Laboratories The Underwriters Laboratories test and register products in accordance with the requirements of the North American market. The approvals are valid for the USA and Canada. GOST GOST certifi cation applies to products tested in accordance with the requirements and standards of the Russian Federation. The GOST standards cover over 20 industries. The Physikalish-Technische Bundesanstalt (PTB) [= Federal Physical/Technical Institute] is a material testing and calibrating body. It is subdivided into several laboratories and, among other things, tests and approves technical equipment for potentially explosive areas. The existing CENELEC standards form the basis. The PTB is the authorised EU testing body for the Federal Republic of Germany. Bundesamt für Wehrtechnik und Beschaffung The Bundesamt für Wehrtechnik und Beschaffung (BWB) [= Federal Offi ce of Military Equipment and Procurement] administers and catalogues the technical equipment of the armed forces. Affi liated to it are technical defence authorities and arsenals, in which type testing is carried out in accordance with VG standards. These materials are listed in the SAK catalogue. The AS-i (Actuator Sensor Interface) is an inexpensive, fast bus system for the transmission of data and energy that reduces cabling and saves on I/O cards and terminal strips. AS-Interface products conform to the EN 50295 and IEC 62026-2 specifi cations. Products marked with the Ex test symbol and test number are approved for use in potentially explosive areas (further details from page 182 onward). ICAO The International Civil Aviation Organization sets standards for technology, quality and safety in international air traffi c. The Allgemeine Verwaltungsvorschrift zur Kennzeichnung von Luftfahrthindernissen (AVV) [= General Administrative Rules for the Identifi cation of Aviation Obstacles] sets the standards for technology, quality and safety in air traffi c in Germany. Russian Maritime Register of Shipping (RS) The Russian Maritime Register of Shipping sets the standards for technology, quality and safety for shipping and industry in the Russian Federation. It additionally functions as a certifying body, for example in the fi elds of defence, the oil and gas industry and building technology. MED MarED is the co-ordination group for the Notifi ed Bodies assigned by the Member States to carry out the conformity assessment procedures referred to in the Marine Equipment Directive (COUNCIL DIRECTIVE 96/98/EC of 20 December 1996 on Marine Equipment). Schweizerische Eidgenossenschaft The Bundesamt für Verkehr (Federal Ministry of Transport) governs public transportation in Switzerland. It covers transport by rail and cable car, freight trains, buses and ships. CNBOP Centrum Naukowo Badawcze Ochrony Przeciwpozarowej The certifi cation department CNBOP-PIB conducts voluntary product certifi cations within the scope of fi re protection for the European and local Polish market. Further technical information can be found on our website at www.pfannenberg.com 39

VISUAL SIGNALING DEVICES 40 www.pfannenberg.com

A FLASH SAYS MORE THAN A THOUSAND WORDS! Visual signaling devices VISUAL SIGNALING DEVICES ENSURE SAFETY AT FIRST SIGHT Regardless of whether you use flashing lights or continuous lights Pfannenberg s visual signaling devices are eye-catchers that can save lives in every respect. They ensure any process status can be displayed in a timely manner. Thanks to their unmistakable demand for action, they offer the best prerequisites for running trouble-free production processes. Benefi t from top quality standards and a unique complete range. Further technical information can be found on our website at www.pfannenberg.com 41

VISUAL SIGNALING DEVICES ALL VISUAL SIGNALING DEVICES AT A GLANCE Type FLASHING LIGHTS Maximum covering distance as per EN 54-23 in metres (m) 1 Flash energy Protection system Dimensions (HxWxD) mm Approvals / Standards EN 54-23 RS GL GOST UL 2,5 5 10 25 50 MED VdS Page PMF 2030 30 joules 46 PMF 2020 7 joules IP 55 direct mounting 185 x Ø 177 bracket mounting 170.5 x Ø 130 48 PMF 2015 7 joules ABL / ABS 15 joules IP 54 without bracket 242 x Ø 80 50 P 400 STR 15 joules IP 65 220 x Ø 140 52 Quadro F12 Quadro S 13 joules 13 joules IP 66 IP 67 IK 08 130 x 130 x 130 54 2 PY X-M-10 10 joules IP 66 IK 08 124 x 166 x 114 2 56 NEW 2 PY X-M-05 5 joules IP 66 IK 08 124 x 166 x 114 2 58 WBL / WBS 5 joules IP 54 200 x Ø 54 60 WBL-PX 5 joules IP 54 200 x Ø 54 WBLR WBSR 5 joules IP 65 144 x 120 x 85 62 P 300 STR 5 joules IP 65 150 x Ø 100 64 1 with a clear lens available in preparation 2 option 42 www.pfannenberg.com

Type FLASHING LIGHTS Maximum covering distance as per EN 54-23 in metres (m) 1 Flash energy / light intensity Protection system Dimensions (HxWxD) mm Approvals / Standards EN 54-23 RS GL GOST UL 2,5 5 10 25 50 MED VdS Page Visual signaling devices 2 PY X-S-05 5 joules IP 66 IK 08 85 x 109.5 x 80.6 2 66 DWBL / DWBS 2.5 joules IP 54 200 x Ø 54 68 LED LIGHTS PMF-LED Flex 30 cd IP 55 direct mounting 185 x Ø 177 bracket mounting 170.5 x Ø 130 70 P 400 LDA 30 cd IP 65 220 x Ø 140 72 P 300 LDA 20 cd IP 65 150 x Ø 100 72 Quadro-LED Flex 9 cd IP 66 IP 67 IK 08 130 x 130 x 130 74 PD 2100-LED 5 cd IP 55 128 x 166.2 x 111.2 76 P 200 LDA 5 cd IP 65 80 x Ø 60 78 P 100 LDA 5 cd IP 65 65.5 x Ø 60 78 Quadro-LED-TL 80 cd IP 66 IK 08 130 x 130 x 396 80 1 with a clear lens available in preparation 2 option Further technical information can be found on our website at www.pfannenberg.com 43

VISUAL SIGNALING DEVICES ALL VISUAL SIGNALING DEVICES AT A GLANCE Type LED LIGHTS Maximum covering distance as per EN 54-23 in metres (m) 1 Light intensity / light power Protection system Dimensions (HxWxD) mm Approvals / Standards EN 54-23 RS GL GOST UL 2,5 5 10 25 50 MED VdS Page P 450 TLA 60 cd IP 65 177 x Ø 140 82 P 350 TLA 45 cd IP 65 140 x Ø 100 82 P 22 D IP 65 52 x Ø 29 84 P 22 DFS IP 65 52 x Ø 29 84 CONTINUOUS LIGHTS PD 2100 15 W IP 55 128 x 166.2 x 111.2 86 P 450 TSB 25 W IP 65 177 x Ø 140 88 P 450 TDB 2 x 15 W P 350 TSB 15 W IP 65 140 x Ø 100 88 ROTATING MIRROR LIGHTS P 400 RTH 35 / 40 W IP 65 220 x Ø 140 90 P 300 RTH 20 / 25 W IP 65 150 x Ø 100 90 1 with a clear lens available in preparation 44 www.pfannenberg.com

Type Maximum covering distance as per EN 54-23 in metres (m) 1 Flash energy / light intensity Protection system Dimensions (HxWxD) mm Approvals / Standards GL GOST UL 2,5 5 10 25 50 MED VdS FUNCTION-MONITORED LIGHTS EN 54-23 RS Page Visual signaling devices Quadro S-M-Flex 13 joules IP 66 IP 67 IK 08 130 x 130 x 130 92 WBL-M / WBS-M 5 joules IP 54 242 x Ø 80 94 PMF 2015-M 7 joules IP 55 direct mounting 185 x Ø 177 bracket mounting 170.5 x Ø 130 96 PD 2100-M-AS-i (LED) 5 cd IP 55 PD 2100-LED-M 5 cd IP 55 128 x 166.2 x 111.2 98 SAFETY-RELATED LIGHTS Quadro F12-SIL 10 joules IP 66 IP 67 IK 08 130 x 130 x 130 100 PMF 2015-SIL 10 joules IP 55 direct mounting 185 x Ø 177 bracket mounting 170.5 x Ø 130 102 1 with a clear lens available in preparation Further information can be found on the Internet: www.pfannenberg.com www.pfannenberg-spareparts.com Keep up to date. Subscribe to our newsletter now: newsletter.pfannenberg.com Further technical information can be found on our website at www.pfannenberg.com 45

VISUAL SIGNALING DEVICES ALL-ROUND FLASHING LIGHT 30 J PMF 2030 Secure 360 alarm for large distances (indoors or outdoors) extremely reliable and durable due to the use of state-of-the-art electronic components no replacement of mechanical or electrical wearing parts necessary reliable performance even under the toughest working and production conditions, e.g. possible voltage fl uctuations, high ambient temperatures up to + 55 C, high relative humidity up to 90% mounting-friendly; large variety of mounting methods bracket-mounting using solid stainless steel bracket or direct mounting with enclosed fl at seal maximum fl ash energy 30 joules good light bundling is achieved in the horizontal plane thanks to the lens in the form of a fresnel lens and the special xenon flash tube very good perceptibility over great distances; low power consumption r = 61 m Covering distance as per EN 54 IP 55 Protection system + 55 C - 40 C Operating temperature Electrical data PMF 2030 Rated voltage 230 V AC Rated frequency 50 / 60 Hz Operating range 195 253 V Nominal current consumption @ 30 J 1 Hz: 450 ma 0.75 Hz: 380 ma 0.5 Hz: 310 ma 0.1 Hz: 150 ma @ 20 J 1 Hz: 400 ma 0.75 Hz: 340 ma 0.5 Hz: 290 ma 0.1 Hz: 140 ma Mechanical data PMF 2030 Light source xenon fl ash tube Flash rate 1 Hz = 60 fl ashes/min., see fl ash frequency table Flash energy max. 30 J, switchable to 20 J Light intensity (DIN 5037) 1 1,500 cd Lens colours clear, amber, red, green, blue Lens type lens with fresnel characteristic Beam angle vertical approx. 16 horizontal 360 Operating temperature - 40 C... + 55 C Storage temperature - 40 C... + 70 C Relative humidity 90% Protection system according to EN 60529 IP 55 (vertical mounting) Duty cycle 100% Service life of the flash tube light emission still 70% after 8,000,000 fl ashes Material lens polycarbonate (PC) housing bracket mounting: polycarbonate (PC) / direct mounting: acrylonitrile butadiene styrene (ABS) Cable entry bracket mounting M20 x 1.5 Connecting terminals single wire 0.5 2.5 mm 2, fi ne wire 0.5 1.5 mm 2, with cable end sleeves DIN 46228/1 bracket mounting 1.25 kg Weight direct mounting 0.75 kg 1 with a clear lens Flash frequencies S1 Flash energy Flash rate 1 2 3 4 OFF OFF OFF OFF 1 Hz ON OFF OFF OFF 0.75 Hz 30 J OFF ON OFF OFF 0.5 Hz ON ON OFF OFF 0.1 Hz S1 Flash energy Flash rate 1 2 3 4 OFF OFF ON OFF 1 Hz ON OFF ON OFF 0.75 Hz 20 J OFF ON ON OFF 0.5 Hz ON ON ON OFF 0.1 Hz 46 www.pfannenberg.com

Dimensions Bracket mounting Direct mounting 170.5 185 Drilling template 1 (for M5 threaded bushing) Ø 5.5 120 Ø 130 Flashing Lights 45 120 M20 x 1.5 75 Ø 130 Ø 177 8.5 M5 threaded bushing Drilling template 2 diameter variable depending on cable entry 6.5 4 45 Ø 5.5 10 Ø 5.5 90 50 50 163 Two different drilling templates are available for fi xing the light (direct mounting). M5 x 8 threaded bushes are set into the base of the light for fi xing according to drilling template 1. Drilling template 2 allows the light to be fi xed using 4 through bolts or similar from above. Ordering details Article numbers PMF 2030 direct mounting PMF 2030 bracket mounting Lens colour Rated voltage 230 V AC 230 V AC amber 210 10 10 4 000 210 10 10 4 010 red 210 10 10 5 000 210 10 10 5 010 Article numbers for other colours and voltages on request Options / Accessories See page 104 for further information GOST Conformity to standards The visual characteristics of fl ashing lights conform to the European standard DIN EN 842: Machine safety - visual alarm signals. Requirements contained in the DIN EN 981 standard: Machine safety - system of acoustic and visual alarm and information signals, can be fulfi lled. The colours red for the emergency signal and yellow for the warning signal conform to the requirements of IEC 73 / DIN EN 60073 / VDE 0199: Coding of display devices and control elements using colours and supplementary means. References to visual alarm devices can be found in the following standards: EN 60825-1 Radiation safety of laser devices, identical to IEC 825 and DIN-VDE 0837 DIN EN 54 Fire alarm systems DIN 54113-2 Radiation protection regulations for the technical operation of X-ray equipment up to 500 kv Further technical information can be found on our website at www.pfannenberg.com 47

VISUAL SIGNALING DEVICES ALL-ROUND FLASHING LIGHTS 14 J PMF 2020 / PMF 2015 r = 22 m IP 55 + 55 C - 40 C Extremely bright due to 14 joules total fl ash energy of the impulse group and light bundling with fesnel lens, low power consumption (energy-saving) choice of three different fl ash combinations with fast fl ash rate (PMF 2015: two fl ash combinations) extremely reliable and durable due to the use of state-of-the-art electronic components no replacement of mechanical or electrical wearing parts necessary large variety of mounting methods direct or using a bracket exchangeable due to broadly used drilling template extremely reliable and durable: fi t it and forget it! especially suitable for cranes and fl oor conveyors highest mechanical stability, shock tested as per DIN EN 60069-2-29 (PMF 2020, GL approval is standard) fl ash tube additionally secured by a steel clamp Covering distance as per EN 54 Protection system Operating temperature Electrical data PMF 2020 PMF 2015 Rated voltage 230 V AC 110 V AC 24 V DC 12 V DC 230 V AC 110 V AC 24 V DC 12 V DC Rated frequency 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz Operating range 195 253 V 90 135 V 18 30 V 11 15 V 195 253 V 90 135 V 18 30 V 11 15 V Nominal current 4 fl ashes0.08 A 0.14 A 0.75 A 1.1 A 0.07 A 0.14 A 0.6 A 1.1 A consumption 2 fl ashes0.09 A 0.15 A 0.8 A 1.15 A 0.08 A 0.16 A 0.65 A 1.2 A single fl ash0.14 A 0.23 A 1 A 1.35 A Mechanical data PMF 2020 PMF 2015 Operating mode quad, double, single fl ash quad, double fl ash Flash energy of the main flash 7 J (12 V: 5 J)7 J Light intensity (DIN 5037) 1 200 cd Lens colours clear, amber, red, green, blue Lens type lens with fresnel characteristic Beam angle vertical approx. 16 horizontal 360 Operating temperature - 40 C... + 55 C Storage temperature - 40 C... + 70 C Relative humidity 90% Protection system according to EN 60529 IP 55 (vertical mounting) Duty cycle 100% Service life of the flash tube light emission still 70% after 8,000,000 fl ashes Material lens polycarbonate (PC) housing bracket mounting: polycarbonate (PC) / direct mounting: acrylonitrile butadiene styrene (ABS) Cable entry bracket mounting M20 x 1.5 M20 x 1.5 for cables 6.5-13.5 mm Connecting terminals single wire 0.5 2.5 mm 2, fi ne wire 0.5 1.5 mm 2, with cable end sleeves DIN 46228/1 Weight bracket mounting AC: 1.1 kg / DC: 1.2 kg direct mounting AC: 0.6 kg / DC: 0.7 kg 1 with a clear lens 48 www.pfannenberg.com

Dimensions Bracket mounting Direct mounting Drilling template 1 (for M5 threaded bushing) 170.5 185 Ø 5.5 120 Ø 130 Flashing Lights M20 x 1.5 75 Ø 130 Ø 177 8.5 45 M5 threaded bushing 120 Drilling template 2 diameter variable depending on cable entry 6.5 4 Ø 5.5 10 Ø 5.5 45 90 50 50 163 Two different drilling templates are available for fi xing the light (direct mounting). M5 x 8 threaded bushes are set into the base of the light for fi xing according to drilling template 1. Drilling template 2 allows the light to be fi xed using 4 through bolts or similar from above. Flash rate Energy single fl ash [J] 7 PMF 2020 PMF 2020 / PMF 2015 single fl ash 240 fl ashes/min. pulse duration 0.25 s Energy single fl ash [J] 7 4 fl ashes 120 fl ashes/min. pulse duration 0.75 s Energy single fl ash [J] 7 2 fl ashes 120 fl ashes/min. pulse duration 0.25 s 3,5 3,5 3,5 1 2 3 4 t [s] 1 2 3 4 t [s] 1 2 3 4 t [s] Ordering details Article numbers PMF 2020 direct mounting GL PMF 2020 bracket mounting GL PMF 2015 direct mounting PMF 2015 bracket mounting Lens colour Rated voltage 230 V AC 24 V DC 230 V AC 24 V DC 230 V AC 24 V DC 230 V AC 24 V DC amber 21009104001 21009804001 21009104011 21009804011 21007104000 21007804000 21007104010 21007804010 red 21009105001 21009805001 21009105011 21009805011 21007105000 21007805000 21007105010 21007805010 Article numbers for other colours and voltages on request Options / Accessories See page 104 for further information GL GOST Conformity to standards The visual characteristics of fl ashing lights conform to the European standard DIN EN 842: Machine safety - visual alarm signals. Requirements contained in the DIN EN 981 standard: Machine safety - system of acoustic and visual alarm and information signals, can be fulfi lled. The colours red for the emergency signal and yellow for the warning signal conform to the requirements of IEC 73 / DIN EN 60073 / VDE 0199: Coding of display devices and control elements using colours and supplementary means. References to visual alarm devices can be found in the following standards: EN 60825-1 Radiation safety of laser devices, identical to IEC 825 and DIN-VDE 0837 DIN EN 54 Fire alarm systems DIN 54113-2 Radiation protection regulations for the technical operation of X-ray equipment up to 500 kv Further technical information can be found on our website at www.pfannenberg.com 49

VISUAL SIGNALING DEVICES FLASHING ALARM LIGHTS 15 J ABL/ABS The powerful fl ashing light in a metal housing designed for alarm functions outdoors and in large halls and plants also available with GL approval housing and fi xing bracket made of sturdy anodised aluminium aggressive environmental conditions or driving rain cannot damage the light impact-proof lens ideally suited for tough industrial environments fl ash tube additionally secured by a steel clamp r = 23 m Covering distance as per EN 54 IP 54 Protection system + 55 C - 40 C Operating temperature Electrical data AC ABL Rated voltage 230 V AC 127 V AC 110 V AC 48 V AC 42 V AC 24 V AC Rated frequency 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz Operating range 185 255 V 108 140 V 95 127 V 40 54 V 35 50 V 20 30 V Nominal current consumption 0.18 A 0.25 A 0.33 A 0.69 A 0.78 A 1.29 A Electrical data DC ABS Rated voltage 60 V DC 48 V DC 36 V DC 24 V DC 12 V DC Operating range 50 72 V 40 60 V 29 43 V 18 30 V 10 15 V Nominal current consumption 0.26 A 0.35 A 0.55 A 0.7 A 1.5 A Mechanical data ABL ABS Flash rate 1 Hz = 60 fl ashes/min. Flash energy 15 J Light intensity (DIN 5037) 1 214 cd Lens colours clear, white, yellow, amber, red, green, blue Operating temperature - 40 C... + 55 C Storage temperature - 40 C... + 70 C Relative humidity 90% Protection system according to EN 60529 IP 54 (vertical mounting) Duty cycle 100% Service life of the flash tube light emission still 70% after 8,000,000 fl ashes lens polycarbonate (PC) Material housing aluminium (Al Mg Si 1), yellow anodised base polycarbonate (PC) with fi bre glass Cable entry M20 x 1.5 Connecting terminals single wire 0.5 2.5 mm 2, fi ne wire 0.5 1.5 mm 2, with cable end sleeves DIN 46228/1 Weight AC 650 g DC 800 g 1 with a clear lens 50 www.pfannenberg.com

Dimensions 242 Flashing Lights Ø 80 Ø 6.5 40 84 50 65 M20 x 1.5 Ordering details Article numbers ABL ABS Lens colour Rated voltage 230 V AC 110 V AC 24 V DC yellow 210 01 10 3 000 210 01 16 3 000 210 01 80 3 000 amber 210 01 10 4 000 210 01 16 4 000 210 01 80 4 000 red 210 01 10 5 000 210 01 16 5 000 210 01 80 5 000 Article numbers for other colours and voltages on request Options / Accessories 30 45 See pages 104/105 for further information GL GOST Article number: 287 10 50 0 042 Conformity to standards The visual characteristics of fl ashing lights conform to the European standard DIN EN 842: Machine safety - visual alarm signals. Requirements contained in the DIN EN 981 standard: Machine safety - system of acoustic and visual alarm and information signals, can be fulfi lled. The colours red for the emergency signal and yellow for the warning signal conform to the requirements of IEC 73 / DIN EN 60073 / VDE 0199: Coding of display devices and control elements using colours and supplementary means. References to visual alarm devices can be found in the following standards: EN 60825-1 Radiation safety of laser devices, identical to IEC 825 and DIN-VDE 0837 DIN EN 54 Fire alarm systems DIN 54113-2 Radiation protection regulations for the technical operation of X-ray equipment up to 500 kv Further technical information can be found on our website at www.pfannenberg.com 51

VISUAL SIGNALING DEVICES SPECTRA FLASHING LIGHT 15 J P 400 STR (Ø 140 MM) Powerful fl ashing alarm light for universal use large variety of mounting methods due to modular design principle: surface-mounted devices for mounting directly or on a wall bracket or a tubular stand also for exposed installation locations through combination of wall bracket and tubular stand cable entry at the side (2 x) or through the base of the housing durable, sturdy and functionally reliable due to the use of high-quality plastic optimum illumination due to prismatic coloured lens electronic components mechanically protected for highest mounting security attracts maximum attention due to adjustable fl ash rates synchronous fl ash sequence operation of several lights r = 20 m Covering distance as per EN 54 IP 65 Protection system + 50 C - 25 C Operating temperature Electrical data P 400 STR Rated voltage 230 V AC 115 V AC 24 V AC/DC Rated frequency 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz / DC Operating range 207 253 V 100 130 V 20 28 V Nominal current consumption 225 ma 400 ma 870 ma Mechanical data P 400 STR Light source xenon fl ash tube Flash rate 230 V / 115 V 1 Hz 24 V 1 Hz / 1.5 Hz / double fl ash Flash energy 15 J @ 1 Hz Light intensity (DIN 5037) 1 165 cd Lens colours clear, yellow, amber, red, green, blue Lens type prismatic Operating temperature - 25 C... + 50 C Relative humidity 90% @ + 20 C Protection system according to EN 60529 IP 65 Service life of the flash tube light emission still 70% after 5,000,000 fl ashes Material polycarbonate (PC) Design bayonet with anti-tamper locking screw Mounting surface mounting (wall bracket and tubular stand available as accessories) Cable entry 1 x 5-7 mm push through grommet (bottom side); 2 x M20 cable entries sideways Connecting terminals screw terminals 1.5 mm 2 Weight AC 632 g DC 696 g 1 with a clear lens 52 www.pfannenberg.com

Dimensions 220 cable entry 2 x M20 cable entry Ø 5-7 mm 25 120 mounting holes 3 x Ø 5.4 mm Ø 110 Flashing Lights 47 20 58 85 Ø 140 120 Ordering details Article numbers P 400 STR Lens colour Rated voltage 230 V AC 115 V AC 24 V AC/DC yellow 213 44 10 3 000 213 44 15 3 000 213 44 40 3 000 amber 213 44 10 4 000 213 44 15 4 000 213 44 40 4 000 red 213 44 10 5 000 213 44 15 5 000 213 44 40 5 000 Article numbers for other colours and voltages on request Options / Accessories Wall bracket Tubular stand 145 mm Wall holder only in combination with tubular stand See pages 106/107 for further information GOST Article number: 213 94 00 0 000 Article number: 213 95 00 0 000 Article number: 282 50 20 0 000 Conformity to standards The visual characteristics of fl ashing lights conform to the European standard DIN EN 842: Machine safety - visual alarm signals. Requirements contained in the DIN EN 981 standard: Machine safety - system of acoustic and visual alarm and information signals, can be fulfi lled. The colours red for the emergency signal and yellow for the warning signal conform to the requirements of IEC 73 / DIN EN 60073 / VDE 0199: Coding of display devices and control elements using colours and supplementary means. References to visual alarm devices can be found in the following standards: EN 60825-1 Radiation safety of laser devices, identical to IEC 825 and DIN-VDE 0837 DIN EN 54 Fire alarm systems DIN 54113-2 Radiation protection regulations for the technical operation of X-ray equipment up to 500 kv Further technical information can be found on our website at www.pfannenberg.com 53

VISUAL SIGNALING DEVICES FLASHING LIGHTS 13 J Quadro F12 / Quadro S Quadro F12 industrial successor to the legendary Eiffel Tower light design adapted to suit industrial requirements; mounted via concealed interior holes or external lugs; fast, fl exible and secure outstanding mechanical strength with IP 66, IP 67 and IK 08; whether in the open air, in a hailstorm or when high pressure cleaning systems are used, the Quadro stays sealed and signals reliably Quadro S automatic synchronised fl ashing light a maximum of 10 fl ashing lights can be operated parallel and synchronously an unlimited time period; i.e. the fl ashes of all lights are generated simultaneously r = 19 m IP 66 IP 67 IK 08 + 55 C - 40 C Sync I lim t 10 Years Covering distance as per EN 54 Protection system Protection system Impact-proof housing Operating temperature Warranty Electrical data Quadro F12 Quadro S Rated voltage 230 V AC 115 V AC 24 V DC 230 V AC Rated frequency 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz Operating range 195 253 V 95 127 V 18 30 V 195 253 V Nominal current consumption 250 ma 340 ma 700 ma 250 ma Initial current limited to < 7 A / 150 µs < 7 A / 150 µs < 5 A / 2 ms < 1 A / 50 ms Mechanical data Quadro F12 Quadro S Flash rate 1 Hz = 60 fl ashes/min. Flash energy 13 J Light intensity (DIN 5037) 1 140 cd Lens colours clear, white, yellow, amber, red, green, blue Operating temperature - 40 C... + 55 C Storage temperature - 40 C... + 70 C Relative humidity 100% Protection system according to EN 60529 IP 66, IP 67, mounting arbitrary Impact resistance as per EN 50102 IK 08 Protection class II Duty cycle 100% Service life of the flash tube light emission still 70% after 12,000,000 fl ashes Material lens polycarbonate (PC) housing polycarbonate (PC), RAL 7035 Cable entry 2 x M20 bottom side / 2 x M20/M32 sideways 2 x M20 sideways Connecting terminals cage clamp terminal 0.08-2.5 mm 2 Mounting Weight external lugs 113 x 153 mm M5 or 127.1 x 127.1 mm M5 internal holes 113 x 113 mm 600 g 1 with a clear lens 54 www.pfannenberg.com

Dimensions Quadro F12 Quadro S 25 130 80 Flashing Lights 47 2 x M20 (M32 prepared) mounting screw e.g. 4 x M4 x 20 39 130 113 113 25 130 80 130 130 113 mounting holes Ø 4.5 2 x M20 prepared 37 113 mounting holes blanking plug M20 x 1.5 cable connection M20 x 1.5 Additional mounting possible via external lugs (included). Ordering details Article numbers Quadro F12 Quadro S Lens colour Rated voltage 230 V AC 115 V AC 24 V DC 230 V AC clear 210 41 10 1 000 210 41 16 1 000 210 41 80 1 000 210 42 10 1 000 yellow 210 41 10 3 000 210 41 16 3 000 210 41 80 3 000 210 42 10 3 000 amber 210 41 10 4 000 210 41 16 4 000 210 41 80 4 000 210 42 10 4 000 red 210 41 10 5 000 210 41 16 5 000 210 41 80 5 000 210 42 10 5 000 Article numbers for other colours and voltages on request Options / Accessories GOST Conformity to standards The visual characteristics of fl ashing lights conform to the European standard DIN EN 842: Machine safety - visual alarm signals. Requirements contained in the DIN EN 981 standard: Machine safety - system of acoustic and visual alarm and information signals, can be fulfi lled. The colours red for the emergency signal and yellow for the warning signal conform to the requirements of IEC 73 / DIN EN 60073 / VDE 0199: Coding of display devices and control elements using colours and supplementary means. References to visual alarm devices can be found in the following standards: EN 60825-1 Radiation safety of laser devices, identical to IEC 825 and DIN-VDE 0837 DIN EN 54 Fire alarm systems DIN 54113-2 Radiation protection regulations for the technical operation of X-ray equipment up to 500 kv Further technical information can be found on our website at www.pfannenberg.com 55

VISUAL SIGNALING DEVICES PYRA FLASHING LIGHT 10 J PY X-M-10 NEW safe an incorrect installation is virtually impossible easy signifi cantly shorter assembly and installation times economical largest possible signaling range due to effective XENON technology installation options with external lugs or internal holes choice of four different fl ash rates via DIP switch suitable for panel mounting electronic constant current regulation at 24 V AC/DC devices to avoid load fl uctuations integrated inrush current limitation and undervoltage detection providing full synchronization on multi-flashing light systems r = 17 m IP 66 IK 08 + 55 C - 40 C EN 54-23 VdS UL Sync I lim t 10 Years Covering distance as per EN 54 Protection system Impact-proof housing Operating temperature pending pending pending Warranty Electrical data PY X-M-10 Rated voltage 230 V AC 115 V AC 24 V AC/DC Rated frequency 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz / DC Operating range 187 255 V 90 135 V Nominal current consumption @ 1 Hz 150 ma 240 ma AC: 18 30 V DC: 10 60 V AC: 1000 ma DC: 540 ma @ 24 V Mechanical data Flash rate Flash energy Light intensity (DIN 5037) 1 Lens colours PY X-M-10 0.1 / 0.5 / 0.75 / 1 Hz (DIP switch) 10 J 118 cd clear, white, yellow, amber, red, green, blue Operating temperature - 40 C... + 55 C Storage temperature - 40 C... + 70 C Relative humidity max. 90% Protection system according to EN 60529 IP 66 Protection class II Duty cycle 100% Service life of the flash tube light emission still 70% after 8,000,000 fl ashes Material Housing colours Cable entry Integrated seal with cable entry lens housing polycarbonate (PC) PC / ABS RAL 3000 (fl ame red) / RAL 7035 (light grey) / RAL 9003 (signal white) 2 x M20 on side, 2 x M20 on bottom 6 13 mm Connecting terminals 2.5 mm 2 fi ne wire, AWG 16 Weight 440 g 1 with a clear lens 56 www.pfannenberg.com

Dimensions 47 124 Flashing Lights 166 114 M20 knock-outs prepared M20 knock-outs prepared 7 Ø 7 Ø 7 154 86 154 Ordering details Article numbers PY X-M-10 housing red Lens colour Rated voltage 230 V AC 115 V AC 24 V AC/DC clear 215 51 10 1 000 215 51 15 1 000 215 51 81 1 000 ¹ yellow 215 51 10 3 000 215 51 15 3 000 215 51 81 3 000 red 215 51 10 5 000 215 51 15 5 000 215 51 81 5 000 ¹ PY X-M-10 housing grey Article numbers Lens colour Rated voltage 230 V AC 115 V AC 24 V AC/DC clear 215 51 10 1 055 215 51 15 1 055 215 51 81 1 055 ¹ yellow 215 51 10 3 055 215 51 15 3 055 215 51 81 3 055 red 215 51 10 5 055 215 51 15 5 055 215 51 81 5 055 ¹ Article numbers for other colours and voltages on request 1 version with EN 54-23 approval Options / Accessories Surface gasket Tamperproof sealing Panel mounting kit See page 105 for further information Conformity to standards The visual characteristics of fl ashing lights conform to the European standard DIN EN 842: Machine safety - visual alarm signals. Requirements contained in the DIN EN 981 standard: Machine safety - system of acoustic and visual alarm and information signals, can be fulfi lled. The colours red for the emergency signal and yellow for the warning signal conform to the requirements of IEC 73 / DIN EN 60073 / VDE 0199: Coding of display devices and control elements using colours and supplementary means. References to visual alarm devices can be found in the following standards: EN 60825-1 Radiation safety of laser devices, identical to IEC 825 and DIN-VDE 0837 DIN EN 54 Fire alarm systems DIN 54113-2 Radiation protection regulations for the technical operation of X-ray equipment up to 500 kv Further technical information can be found on our website at www.pfannenberg.com 57

VISUAL SIGNALING DEVICES PYRA FLASHING LIGHT 5 J PY X-M-05 NEW safe an incorrect installation is virtually impossible easy signifi cantly shorter assembly and installation times economical largest possible signaling range due to effective XENON technology installation options with external lugs or internal holes choice of four different fl ash rates via DIP switch suitable for panel mounting electronic constant current regulation at 24 V AC/DC devices to avoid load fl uctuations integrated inrush current limitation and undervoltage detection providing full synchronization on multi-flashing light systems r = 11 m IP 66 IK 08 + 55 C - 40 C EN 54-23 VdS UL Sync I lim t 10 Years Covering distance as per EN 54 Protection system Impact-proof housing Operating temperature pending pending pending Warranty Electrical data PY X-M-05 Rated voltage 230 V AC 115 V AC 24 V AC/DC Rated frequency 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz / DC Operating range 187 255 V 90 135 V Nominal current consumption @ 1 Hz 60 ma 110 ma AC: 18 30 V DC: 10 60 V AC: 600 ma DC: 280 ma @ 24 V Mechanical data Flash rate Flash energy Light intensity (DIN 5037) 1 Lens colours PY X-M-05 0.1 / 0.5 / 0.75 / 1 Hz (DIP switch) 5 J 44 cd clear, white, yellow, amber, red, green, blue Operating temperature - 40 C... + 55 C Storage temperature - 40 C... + 70 C Relative humidity max. 90% Protection system according to EN 60529 IP 66 Protection class II Duty cycle 100% Service life of the flash tube light emission still 70% after 8,000,000 fl ashes Material Housing colours Cable entry Integrated seal with cable entry lens housing polycarbonate (PC) PC / ABS RAL 3000 (fl ame red) / RAL 7035 (light grey) / RAL 9003 (signal white) 2 x M20 on side, 2 x M20 on bottom 6 13 mm Connecting terminals 2.5 mm 2 fi ne wire, AWG 16 Weight 1 with a clear lens AC AC/DC 400 g 420 g 58 www.pfannenberg.com

Dimensions 47 124 Flashing Lights 166 114 M20 knock-outs prepared M20 knock-outs prepared 7 Ø 7 Ø 7 154 86 154 Ordering details Article numbers PY X-M-05 housing red Lens colour Rated voltage 230 V AC 115 V AC 24 V AC/DC clear 215 50 10 1 000 215 50 15 1 000 215 50 81 1 000 ¹ yellow 215 50 10 3 000 215 50 15 3 000 215 50 81 3 000 red 215 50 10 5 000 215 50 15 5 000 215 50 81 5 000 ¹ Article numbers PY X-M-05 housing grey Lens colour Rated voltage 230 V AC 115 V AC 24 V AC/DC clear 215 50 10 1 055 215 50 15 1 055 215 50 81 1 055 ¹ yellow 215 50 10 3 055 215 50 15 3 055 215 50 81 3 055 red 215 50 10 5 055 215 50 15 5 055 215 50 81 5 055 ¹ Article numbers for other colours and voltages on request 1 version with EN 54-23 approval Options / Accessories Surface gasket Tamperproof sealing Panel mounting kit See page 105 for further information Conformity to standards The visual characteristics of fl ashing lights conform to the European standard DIN EN 842: Machine safety - visual alarm signals. Requirements contained in the DIN EN 981 standard: Machine safety - system of acoustic and visual alarm and information signals, can be fulfi lled. The colours red for the emergency signal and yellow for the warning signal conform to the requirements of IEC 73 / DIN EN 60073 / VDE 0199: Coding of display devices and control elements using colours and supplementary means. References to visual alarm devices can be found in the following standards: EN 60825-1 Radiation safety of laser devices, identical to IEC 825 and DIN-VDE 0837 DIN EN 54 Fire alarm systems DIN 54113-2 Radiation protection regulations for the technical operation of X-ray equipment up to 500 kv Further technical information can be found on our website at www.pfannenberg.com 59

VISUAL SIGNALING DEVICES FLASHING WARNING LIGHTS 5 J WBL/WBS / WBL-PX The classics of fl ashing lights sturdy metal housing universally usable also available with GL approval housing and fi xing bracket made of sturdy anodised aluminium aggressive environmental conditions or driving rain cannot damage the light impact-proof lens ideally suited for tough industrial environments fl ash tube additionally secured by a steel clamp r = 11 m IP 54 + 55 C - 40 C I lim t Covering distance as per EN 54 Protection system Operating temperature WBL-PX Electrical data AC WBL Rated voltage 230 V AC 110 V AC 48 V AC 42 V AC 24 V AC Rated frequency 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz Operating range 185 255 V 90 135 V 40 54 V 35 50 V 20 30 V Nominal current consumption 0.07 A 0.1 A 0.47 A 0.5 A 0.77 A Electrical data DC WBS Rated voltage 110 V DC 80 V DC 60 V DC 48 V DC 24 V DC 12 V DC Operating range 88 132 V 64 96 V 50 72 V 40 60 V 18 35 V 10 15 V Nominal current consumption 0.09 A 0.11 A 0.13 A 0.18 A 0.25 A 0.6 A Electrical data WBL-PX Rated voltage 230 V AC Rated frequency 50 / 60 Hz Operating range 185 255 V Nominal current consumption 0.055 A Initial current limited to 6 A / 110 µs Mechanical data WBL WBS WBL-PX Flash rate 1 Hz = 60 fl ashes/min. Flash energy 5 J Light intensity (DIN 5037) 1 44 cd Lens colours clear, white, yellow, amber, red, green, blue Operating temperature - 40 C... + 55 C Storage temperature - 40 C... + 70 C Relative humidity 90% Protection system according to EN 60529 IP 54 (vertical mounting) Duty cycle 100% Service life of the flash tube light emission still 70% after 8,000,000 fl ashes lens polycarbonate (PC) Material housing aluminium (Al Mg Si 1), yellow anodised base polycarbonate (PC) with fi bre glass Cable entry M20 x 1.5 Connecting terminals single wire 0.5 2.5 mm 2, fi ne wire 0.5 1.5 mm 2, with cable end sleeves DIN 46228/1 Weight AC 260 g 260 g DC 300 g 1 with a clear lens 60 www.pfannenberg.com

Dimensions Flashing Lights Ø 54 Ø 6.5 30 64 200 36 50 M20 Ordering details Article numbers WBL WBS Lens colour Rated voltage 230 V AC 110 V AC 60 V DC 24 V DC yellow 210 03 10 3 000 210 03 16 3 000 210 03 65 3 000 210 03 80 3 000 amber 210 03 10 4 000 210 03 16 4 000 210 03 65 4 000 210 03 80 4 000 red 210 03 10 5 000 210 03 16 5 000 210 03 65 5 000 210 03 80 5 000 Article numbers WBL-PX Lens colour Rated voltage 230 V AC yellow 210 03 10 3 175 Article numbers for other colours and voltages on request Options / Accessories 30 90 120 I lim t See pages 104/105 for further information GL GOST Article number: 287 10 50 0 041 Conformity to standards The visual characteristics of fl ashing lights conform to the European standard DIN EN 842: Machine safety - visual alarm signals. Requirements contained in the DIN EN 981 standard: Machine safety - system of acoustic and visual alarm and information signals, can be fulfi lled. The colours red for the emergency signal and yellow for the warning signal conform to the requirements of IEC 73 / DIN EN 60073 / VDE 0199: Coding of display devices and control elements using colours and supplementary means. References to visual alarm devices can be found in the following standards: EN 60825-1 Radiation safety of laser devices, identical to IEC 825 and DIN-VDE 0837 DIN EN 54 Fire alarm systems DIN 54113-2 Radiation protection regulations for the technical operation of X-ray equipment up to 500 kv Further technical information can be found on our website at www.pfannenberg.com 61

VISUAL SIGNALING DEVICES FLASHING WARNING LIGHTS 5 J WBLR/WBSR Visual alarm in compact plastic housing especially suitable for outdoor applications due to high protection system mounting via concealed interior holes safe mounting without breaching IP protection fl ash tube additionally secured by a steel clamp r = 11 m IP 65 + 55 C - 40 C VdS Covering distance as per EN 54 Protection system Operating temperature 24 V DC, 48 V DC Electrical data AC WBLR Rated voltage 230 V AC 110 V AC 48 V AC 42 V AC 24 V AC Rated frequency 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz Operating range 185 255 V 90 135 V 40 54 V 35 50 V 20 30 V Nominal current consumption 0.07 A 0.1 A 0.47 A 0.5 A 0.77 A Electrical data DC WBSR Rated voltage 110 V DC 80 V DC 60 V DC 48 V DC 24 V DC 12 V DC Operating range 88 132 V 64 96 V 50 72 V 40 60 V 18 35 V 10 15 V Nominal current consumption 0.09 A 0.11 A 0.13 A 0.18 A 0.25 A 0.6 A Mechanical data WBLR WBSR Flash rate 1 Hz = 60 fl ashes/min. Flash energy 5 J Light intensity (DIN 5037) 1 44 cd Lens colours clear, white, yellow, amber, red, green, blue Operating temperature - 40 C... + 55 C Storage temperature - 40 C... + 70 C Relative humidity 90% Protection system according to EN 60529 IP 65 Duty cycle 100% Service life of the flash tube light emission still 70% after 8,000,000 fl ashes Material lens polycarbonate (PC) housing ABS, light grey, similar to RAL 7035 Cable entry M20 x 1.5 Connecting terminals single wire 0.5 2.5 mm 2, fi ne wire 0.5 1.5 mm 2, with cable end sleeves DIN 46228/1 Weight AC 290 g DC 300 g 1 with a clear lens 62 www.pfannenberg.com

Dimensions Ø 54 80 144 Flashing Lights M20 x 1.5 120 37 50 85 M20 x 1.5 Mounting holes 50 Ø 4.1 108 Ordering details Article numbers WBLR WBSR Lens colour Rated voltage 230 V AC 110 V AC 24 V DC yellow 210 04 10 3 000 210 04 16 3 000 210 04 80 3 000 amber 210 04 10 4 000 210 04 16 4 000 210 04 80 4 000 red 210 04 10 5 000 210 04 16 5 000 210 04 80 5 000 Article numbers for other colours and voltages on request Options / Accessories 30 90 120 See pages 104/105 for further information GLArticle GOST number: 287 10 50 0 043 Conformity to standards The visual characteristics of fl ashing lights conform to the European standard DIN EN 842: Machine safety - visual alarm signals. Requirements contained in the DIN EN 981 standard: Machine safety - system of acoustic and visual alarm and information signals, can be fulfi lled. The colours red for the emergency signal and yellow for the warning signal conform to the requirements of IEC 73 / DIN EN 60073 / VDE 0199: Coding of display devices and control elements using colours and supplementary means. References to visual alarm devices can be found in the following standards: EN 60825-1 Radiation safety of laser devices, identical to IEC 825 and DIN-VDE 0837 DIN EN 54 Fire alarm systems DIN 54113-2 Radiation protection regulations for the technical operation of X-ray equipment up to 500 kv Further technical information can be found on our website at www.pfannenberg.com 63

VISUAL SIGNALING DEVICES SPECTRA FLASHING LIGHT 5 J P 300 STR (Ø 100 MM) Flashing warning light for universal use large variety of mounting methods due to modular design principle: surface-mounted devices for mounting directly or on a wall bracket or a tubular stand also for exposed installation locations through combination of wall bracket and tubular stand cable entry at the side or through the base of the housing durable, sturdy and functionally reliable due to the use of high-quality plastic optimum illumination due to prismatic coloured lens electronic components mechanically protected for highest mounting security synchronous fl ash sequence operation of several lights r = 10 m Covering distance as per EN 54 IP 65 Protection system + 50 C - 25 C Operating temperature Electrical data P 300 STR Rated voltage 230 V AC 115 V AC24 V AC/DC Rated frequency 50 / 60 Hz 50 / 60 Hz 20 28 V Operating range 207 253 V 100 130 V 250 ma / 300 ma Nominal current consumption 35 ma 70 ma Mechanical data P 300 STR Light source xenon fl ash tube Flash rate 230 V / 115 V 1 Hz 24 V 1 Hz / 1.5 Hz / double fl ash Flash energy 5 J @ 1 Hz Light intensity (DIN 5037) 1 40 cd Lens colours clear, yellow, amber, red, green, blue Lens type prismatic Operating temperature - 25 C... + 50 C Relative humidity 90% @ + 20 C Protection system according to EN 60529 IP 65 Service life of the flash tube light emission still 70% after 5,000,000 fl ashes Material polycarbonate (PC), UL 94 VO f1 Design bayonet with anti-tamper locking screw Mounting surface mounting (wall bracket and tubular stand available as accessories) Cable entry 1 x 5-7 mm push through grommet (bottom side); 1 x M20 cable entry sideways Connecting terminals screw terminals 1.5 mm 2 Weight AC 300 g DC 325 g 1 with a clear lens 64 www.pfannenberg.com

Dimensions 150 cable entry M20 27 mounting holes 2 x Ø 5.4 mm Flashing Lights cable entry Ø 5-7 mm 20 37 55 27.5 45 60 Ø 100 Ordering details Article numbers P 300 STR Lens colour Rated voltage 230 V AC 115 V AC24 V AC/DC yellow 213 34 10 3 000 213 34 15 3 000 213 34 40 3 000 amber 213 34 10 4 000 213 34 15 4 000 213 34 40 4 000 red 213 34 10 5 000 213 34 15 5 000 213 34 40 5 000 Article numbers for other colours and voltages on request Options / Accessories Wall bracket Tubular stand 140 mm Wall holder only in combination with tubular stand See pages 106/107 for further information GOST Article number: 213 92 00 0 000 Article number: 213 93 00 0 000 Article number: 282 50 20 0 000 Conformity to standards The visual characteristics of fl ashing lights conform to the European standard DIN EN 842: Machine safety - visual alarm signals. Requirements contained in the DIN EN 981 standard: Machine safety - system of acoustic and visual alarm and information signals, can be fulfi lled. The colours red for the emergency signal and yellow for the warning signal conform to the requirements of IEC 73 / DIN EN 60073 / VDE 0199: Coding of display devices and control elements using colours and supplementary means. References to visual alarm devices can be found in the following standards: EN 60825-1 Radiation safety of laser devices, identical to IEC 825 and DIN-VDE 0837 DIN EN 54 Fire alarm systems DIN 54113-2 Radiation protection regulations for the technical operation of X-ray equipment up to 500 kv Further technical information can be found on our website at www.pfannenberg.com 65

VISUAL SIGNALING DEVICES PYRA COMPACT FLASHING LIGHT 5 J PY X-S-05 The compact fl ashing light is not only adaptable to many applications, but it is also impressive due to its safe and simple mounting installation options with external lugs or internal holes simple electrical connection on the bottom of the casing impact-proof lens suitable for panel mounting housing colours: red, grey or white optional with Soft-Start-Module for reduction of starting current modular design: housing can be easily stacked side-by side EN 54-23-relevant data you can find on pages 20-22, or just call us! r = 11 m IP 66 IK 08 + 55 C - 40 C EN 54-23 VdS UL 10 Years Covering distance as per EN 54 Protection system Impact-proof housing Operating temperature 24 V DC, 48 V DC 24 V DC, 48 V DC Warranty Electrical data PY X-S-05 Rated voltage 230 V AC 115 V AC 24 V AC 48 V DC 24 V DC 12 V DC Rated frequency 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz Operating range 187 255 V 90 135 V 18 30 V 40 60 V 18 30 V 12 15 V Nominal current consumption 55 ma 100 ma 800 ma 170 ma 300 ma 600 ma Mechanical data PY X-S-05 Flash rate 1 Hz = 60 fl ashes/min. Flash energy 5 J Light intensity (DIN 5037) 1 44 cd (max. 55 cd) Lens colours clear, white, yellow, amber, red, green, blue Operating temperature - 40 C... + 55 C Storage temperature - 40 C... + 70 C Relative humidity max. 90% Protection system according to EN 60529 IP 66 Protection class II Duty cycle 100% Service life of the flash tube light emission still 70% after 8,000,000 fl ashes Material lens polycarbonate (PC) housing PC / ABS blend Colour housing similar to RAL 3000 (fl ame red) / RAL 7035 (light grey) / RAL 9003 (signal white) Cable entry 3 x M20 knock-outs on side, 1 knock-out on back Integrated seal with cable entry 6 13 mm (feed-through grommet) Connecting terminals 2.5 mm 2 fi ne wire with cable end sleeve, AWG 16 Weight AC 165 g DC 200 g 1 with a clear lens 66 www.pfannenberg.com

Dimensions 109.5 98 80.6 Ø 6.3 Flashing Lights 85.8 M20 37 knock-outs prepared 22 Ordering details Article numbers PY X-S-05 housing red Lens colour Rated voltage 230 V AC 115 V AC 24 V DC clear 215 10 80 1 000 ¹ yellow 215 10 10 3 000 215 10 15 3 000 215 10 80 3 000 amber 215 10 10 4 000 215 10 15 4 000 215 10 80 4 000 red 215 10 10 5 000 215 10 15 5 000 215 10 80 5 000 ¹ Article numbers PY X-S-05 housing grey Lens colour Rated voltage 230 V AC 115 V AC 24 V DC clear 215 10 15 1 055 215 10 80 1 055 ¹ yellow 215 10 10 3 055 215 10 15 3 055 215 10 80 3 055 amber 215 10 10 4 055 215 10 15 4 055 215 10 80 4 055 red 215 10 10 5 055 215 10 15 5 055 215 10 80 5 055 ¹ Article numbers for other colours and voltages on request 1 version with EN 54-23 approval Options / Accessories Enclosure fitting Surface gasket Tamperproof sealing Panel mounting kit I lim t See pages 105/108 for further information GL MED CNBOP SSM (only for 24 V DC) Conformity to standards The visual characteristics of fl ashing lights conform to the European standard DIN EN 842: Machine safety - visual alarm signals. Requirements contained in the DIN EN 981 standard: Machine safety - system of acoustic and visual alarm and information signals, can be fulfi lled. The colours red for the emergency signal and yellow for the warning signal conform to the requirements of IEC 73 / DIN EN 60073 / VDE 0199: Coding of display devices and control elements using colours and supplementary means. References to visual alarm devices can be found in the following standards: EN 60825-1 Radiation safety of laser devices, identical to IEC 825 and DIN-VDE 0837 DIN EN 54 Fire alarm systems DIN 54113-2 Radiation protection regulations for the technical operation of X-ray equipment up to 500 kv Further technical information can be found on our website at www.pfannenberg.com 67

VISUAL SIGNALING DEVICES FLASHING WARNING LIGHTS 2.5 J DWBL/DWBS Flashing light for direct installation at the workstation no dazzle but secure alarm function also available with GL approval housing and fi xing bracket made of sturdy anodised aluminium impact-proof lens fl ash tube additionally secured by a steel clamp r = 5 m Covering distance as per EN 54 IP 54 Protection system + 55 C - 40 C Operating temperature Electrical data AC DWBL Rated voltage 230 V AC 110 V AC 48 V AC 42 V AC 24 V AC Rated frequency 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz Operating range 185 255 V 90 135 V 40 54 V 35 50 V 20 30 V Nominal current consumption 0.04 A 0.05 A 0.26 A 0.29 A 0.5 A Electrical data DC DWBS Rated voltage 12 V DC 24 V DC 48 V DC 60 V DC 80 V DC Operating range 10 15 V 18 30 V 40 60 V 50 72 V 64 96 V Nominal current consumption 0.27 A 0.15 A 0.1 A 0.07 A 0.067 A Mechanical data DWBL DWBS Flash rate 1 Hz = 60 fl ashes/min. Flash energy 2.5 J Light intensity (DIN 5037) 1 8 cd Lens colours clear, white, yellow, amber, red, green, blue Operating temperature - 40 C... + 55 C Storage temperature - 40 C... + 70 C Relative humidity 90% Protection system according to EN 60529 IP 54 (vertical mounting) Duty cycle 100% Service life of the flash tube light emission still 70% after 8,000,000 fl ashes lens polycarbonate (PC) Material housing aluminium (Al Mg Si 1), yellow anodised base polycarbonate (PC) with fi bre glass Cable entry M20 x 1.5 Connecting terminals single wire 0.5 2.5 mm 2, fi ne wire 0.5 1.5 mm 2, with cable end sleeves DIN 46228/1 Weight AC 270 g DC 300 g 1 with a clear lens 68 www.pfannenberg.com

Dimensions Flashing Lights Ø 54 Ø 6.5 30 64 200 36 50 M20 Ordering details Article numbers DWBL DWBS Lens colour Rated voltage 230 V AC 110 V AC 24 V DC yellow 210 05 10 3 000 210 05 16 3 000 210 05 80 3 000 amber 210 05 10 4 000 210 05 16 4 000 210 05 80 4 000 red 210 05 10 5 000 210 05 16 5 000 210 05 80 5 000 Article numbers for other colours and voltages on request Options / Accessories 30 90 120 See pages 104/105 for further information GLArticle GOST number: 287 10 50 0 041 Conformity to standards The visual characteristics of fl ashing lights conform to the European standard DIN EN 842: Machine safety - visual alarm signals. Requirements contained in the DIN EN 981 standard: Machine safety - system of acoustic and visual alarm and information signals, can be fulfi lled. The colours red for the emergency signal and yellow for the warning signal conform to the requirements of IEC 73 / DIN EN 60073 / VDE 0199: Coding of display devices and control elements using colours and supplementary means. References to visual alarm devices can be found in the following standards: EN 60825-1 Radiation safety of laser devices, identical to IEC 825 and DIN-VDE 0837 DIN EN 54 Fire alarm systems DIN 54113-2 Radiation protection regulations for the technical operation of X-ray equipment up to 500 kv Further technical information can be found on our website at www.pfannenberg.com 69

VISUAL SIGNALING DEVICES LED MULTI-FUNCTION LIGHT PMF-LED Flex r = 9 m Covering distance as per EN 54 IP 55 Protection system + 55 C - 30 C Operating temperature Multi-function light with the brightest LED technology rotating mirror effect, extremely low power consumption highly insensitive to vibration maintenance-free service life exceeding 50,000 hrs externally selectable operating mode, one device for 4 different alarms: continuous light blinking light fl ashing light rotating beacon effect without susceptible mechanics inexpensive and fl exible; wide range power supplies as standard 24 V AC/DC devices as standard with soft-start module can be operated directly via 24 V transistor PLC output, no additional relay control necessary long-life replacement for conventional rotating mirror lights Electrical datapmf-led Flex Rated voltage 115 V AC 230 V AC 230 V DC 24 V AC/DC Operating range 95 253 V AC 100 350 V DC 10 60 V DC 15 40 V AC Current consumption in continuous light mode Mechanical data 90 ma 60 ma 55 ma DC: 250 ma PMF-LED Flex Operating mode continuous light blinking light fl ashing light rotating all-round light Flash rate of the main flash 1.5 Hz 1 Hz 2.5 Hz Light source 8 x 2 LEDs (3 chip version) Light intensity (DIN 5037) 1 30 cd Lens colours amber, red, green, blue Lens type lens with fresnel characteristic Beam angle vertical approx. 16 horizontal 360 Operating temperature - 30 C... + 55 C Storage temperature - 40 C... + 70 C Relative humidity 90% Protection system according to EN 60529 IP 55 (vertical mounting) Duty cycle 100% Service life of light source > 50,000 hrs Material lens polycarbonate (PC) housing bracket mounting: polycarbonate (PC) / direct mounting: acrylonitrile butadiene styrene (ABS) Cable entry bracket mounting M20 x 1.5 Connecting terminals cage clamp terminal 0.08-2.5 mm 2 Weight direct mounting: 620 g / bracket mounting: 900 g 1 with a clear lens Operating modes S1 Selection via 1 2 3 internal DIP switch OFF OFF OFF OFF OFF OFF ON all-round light 2.5 Hz OFF ON OFF continuous light OFF ON ON blinking light 1.5 Hz ON OFF OFF fl ashing light 1 Hz ON OFF ON all-round light 2.5 Hz ON ON OFF continuous light ON ON ON blinking light 1.5 Hz S1 - X1 - Selection via 1 1 2 3 4 external control (S1-2 = OFF, S1-3 = OFF) OFF -/N +/L OFF (standby) OFF -/N +/L +/L all-round light 2.5 Hz OFF -/N +/L +/L continuous light OFF -/N +/L +/L +/L blinking light 1.5 Hz ON -/N +/L fl ashing light 1 Hz ON -/N +/L +/L all-round light 2.5 Hz ON -/N +/L +/L continuous light ON -/N +/L +/L +/L blinking light 1.5 Hz S1 - X1 - Selection via 1 1 2 3 4 BAV option (S1-2 = OFF, S1-3 = OFF) (24 V AC/DC only) OFF -/N +/L all-round light 2.5 Hz OFF -/N +/L continuous light OFF -/N +/L +/L blinking light 1.5 Hz ON -/N +/L fl ashing light 1 Hz ON -/N +/L all-round light 2.5 Hz ON -/N +/L continuous light ON -/N +/L +/L blinking light 1.5 Hz 70 www.pfannenberg.com

Dimensions Bracket mounting Direct mounting 45 185 LED Lights M20 x 1.5 75 Ø 130 Ø 177 8.5 M5 threaded bushing 6.5 4 Ø 5.5 10 90 50 45 170.5 50 Drilling template 1 for M5 threaded bushing Drilling template 2 120 diameter variable depending on cable entry Ø 5.5 Ø 130 Ø 5.5 120 diameter variable depending on cable entry 163 Ordering details Article numbers PMF-LED Flex direct mounting PMF-LED Flex bracket mounting Lens colour Rated voltage 230 V 24 V AC/DC 230 V 24 V AC/DC amber 211 51 64 4 006 211 51 63 4 006 211 51 64 4 007 211 51 63 4 007 red 211 51 64 5 006 211 51 63 5 006 211 51 64 5 007 211 51 63 5 007 Article numbers for other colours on request Conformity to standards The visual characteristics of LED lights conform to the European standard DIN EN 842: Machine safety - visual alarm signals. Requirements contained in the DIN EN 981 standard: Machine safety - system of acoustic and visual alarm and information signals, can be fulfi lled. The colours red for the emergency signal and yellow for the warning signal conform to the requirements of IEC 73 / DIN EN 60073 / VDE 0199: Coding of display devices and control elements using colours and supplementary means. References to visual alarm devices can be found in the following standards: EN 60825-1 Radiation safety of laser devices, identical to IEC 825 and DIN-VDE 0837 DIN EN 54 Fire alarm systems DIN 54113-2 Radiation protection regulations for the technical operation of X-ray equipment up to 500 kv Further technical information can be found on our website at www.pfannenberg.com 71

VISUAL SIGNALING DEVICES SPECTRA LED MULTI-FUNCTION LIGHTS P 400 LDA (Ø 140 MM) / P 300 LDA (Ø 100 MM) P 400 LDA P 300 LDA LED multi-function lights for extreme requirements energy-saving and durable thanks to the use of maintenance-free LED technology as standard with on-site selectable signaling mode (9 different modes) externally switchable signaling mode (for DC versions only) large variety of mounting methods due to modular design principle: surface-mounted devices for mounting directly or on a wall bracket or a tubular stand also for exposed installation locations through combination of wall bracket and tubular stand cable entry at the side or through the base of the housing durable, sturdy and functionally reliable due to the use of high-quality plastic optimum illumination due to prismatic coloured lens r = 9 m r = 7 m IP 65 + 50 C - 25 C Covering distance as per EN 54 Covering distance as per EN 54 Protection system Operating temperature Electrical data P 400 LDA P 300 LDA Rated voltage 115 V AC 230 V AC 12 / 24 V DC 115 / 230 V AC 12 / 24 V DC Operating range 100 130 V 207 253 V 10 50 V 90 253 V 10 50 V Nominal current consumption 140 ma 70 ma 400 ma @ 24 V DC 90 ma @ 115 V AC 50 ma @ 230 V AC Mechanical data P 400 LDA P 300 LDA Operating mode LED multi-function light with 9 internally selectable operating modes Light source high output LED array Light intensity (DIN 5037) 1 30 cd 20 cd Lens colours Lens type yellow, amber, red, green, blue prismatic Operating temperature - 25 C... + 50 C Relative humidity 90% @ + 20 C Protection system according to EN 60529 IP 65 Service life of light source > 50,000 hrs Material Design Mounting Cable entry polycarbonate (PC), UL 94 VO f1 bayonet with anti-tamper locking screw surface mounting (wall bracket and tubular stand available as accessories) 1 x 5-7 mm push through grommet (bottom side); 2 x M20 cable entries sideways Connecting terminals screw terminals 1.5 mm 2 130 ma @ 24 V DC Weight 1 with a clear lens AC 595 g 285 g DC 845 g 285 g Operating modes Stage 1: internally selectable, stages 2 & 3 externally controllable (DC lights only) P 400 LDA P 300 LDA Mode Stage 1 Stage 2 (only DC) Stage 3 (only DC) Stage 1 Stage 2 (only DC) 1 all LEDs on alternating fl ash 2 Hz double fl ash 2 Hz all LEDs on alternating fl ash 2 Hz 2 rotation: slow on alternating fl ash 2 Hz all LEDs on rotation: slow on alternating fl ash 2 Hz 3 single fl ash 2 Hz rotation: fast off all LEDs on single fl ash 2 Hz rotation: fast off 4 rotation: fast on single fl ash 2 Hz all LEDs on rotation: fast on single fl ash 2 Hz 5 rotation: slow off double fl ash 1 Hz all LEDs on rotation: slow off double fl ash 1 Hz 6 double fl ash 1 Hz rotation: fast off all LEDs on double fl ash 1 Hz rotation: fast off 7 rotation: fast off double fl ash 2 Hz all LEDs on rotation: fast off double fl ash 2 Hz 8 double fl ash 2 Hz alternating fl ash 2 Hz double fl ash 2 Hz alternating fl ash 2 Hz all LEDs on 9 alternating fl ash 2 Hz rotation: fast off alternating fl ash 2 Hz rotation: fast off all LEDs on 72 www.pfannenberg.com

Dimensions P 400 LDA P 300 LDA 220 cable entry 2 x M20 150 cable entry M20 LED Lights 20 58 20 37 Ø 140 Ø 100 cable entry Ø 5-7 mm 120 mounting holes 3 x Ø 5.4 mm 27 mounting holes 2 x Ø 5.4 mm 25 Ø 110 cable entry Ø 5-7 mm 27.5 55 47 85 120 45 60 Ordering details Article numbers P 400 LDA P 300 LDA Lens colour Rated voltage 230 V AC 115 V AC 12 / 24 V DC 115 / 230 V AC 12 / 24 V DC yellow 213 48 10 3 000 213 48 15 3 000 213 48 90 3 000 213 38 17 3 000 213 38 90 3 000 amber 213 48 10 4 000 213 48 15 4 000 213 48 90 4 000 213 38 17 4 000 213 38 90 4 000 red 213 48 10 5 000 213 48 15 5 000 213 48 90 5 000 213 38 17 5 000 213 38 90 5 000 Article numbers for other colours on request Options / Accessories Wall bracket for P 400 Wall bracket for P 300 Tubular stand 145 mm for P 400 Tubular stand 140 mm for P 300 Wall holder only in combination with tubular stand See pages 106/107 for further information GOST Article number: 213 94 00 0 000 Article number: 213 92 00 0 000 Article number: 213 95 00 0 000 Article number: 213 93 00 0 000 Article number: 282 50 20 0 000 Conformity to standards The visual characteristics of LED lights conform to the European standard DIN EN 842: Machine safety - visual alarm signals. Requirements contained in the DIN EN 981 standard: Machine safety - system of acoustic and visual alarm and information signals, can be fulfi lled. The colours red for the emergency signal and yellow for the warning signal conform to the requirements of IEC 73 / DIN EN 60073 / VDE 0199: Coding of display devices and control elements using colours and supplementary means. References to visual alarm devices can be found in the following standards: EN 60825-1 Radiation safety of laser devices, identical to IEC 825 and DIN-VDE 0837 DIN EN 54 Fire alarm systems DIN 54113-2 Radiation protection regulations for the technical operation of X-ray equipment up to 500 kv Further technical information can be found on our website at www.pfannenberg.com 73

VISUAL SIGNALING DEVICES LED MULTI-FUNCTION LIGHT Quadro-LED Flex designed for tough requirements under industrial conditions suitable for indoor and outdoor use extremely insensitive to shock and vibration internally and externally selectable operating mode as standard - one device for 4 different alarms: continuous light blinking light fl ashing light rotating light (non-wearing) 24 V AC/DC devices as standard with soft-start module can be operated directly via 24 V transistor PLC output, no additional relay control necessary inexpensive and fl exible; wide range power supplies as standard r = 5 m IP 66 IP 67 IK 08 + 55 C - 30 C 10 Years Covering distance as per EN 54 Protection system Protection system Impact-proof housing Operating temperature Warranty Electrical data Quadro-LED Flex Rated voltage 115 / 230 V AC/DC 24 V AC/DC Rated frequency 50 / 60 Hz / DC 50 / 60 Hz / DC Operating range Current consumption in continuous light mode Mechanical data AC 95 V 253 V 15 V 40 V DC 100 V 350 V 10 V 60 V AC 115 V: < 90 ma 230 V: 60 ma 24 V: 420 ma DC 120 V: < 55 ma 220 V: 35 ma 24 V: 250 ma Quadro-LED Flex Operating mode (internally and externally selectable) continuous light blinking light fl ashing light rotating all-round light Light alternation frequency 1.5 Hz 1 Hz 2.5 Hz Light source Light intensity (DIN 5037) 1 Lens colours LED; 8 x 2 LEDs (3 chip version) 9 cd clear, white, yellow, amber, red, green, blue Operating temperature - 30 C... + 55 C Storage temperature - 40 C... + 70 C Relative humidity 100% Protection system according to EN 60529 IP 66, IP 67, mounting arbitrary Impact resistance as per EN 50102 IK 08 Protection class Service life of light source Material Cable entry lens II 50,000 hrs polycarbonate (PC) housing polycarbonate (PC), grey RAL 7035 2 x M20/M32 sideways, 2 x M20 bottom side Connecting terminals spring-type terminal 0.08 2.5 mm 2 Weight 1 with a clear lens 500 g 74 www.pfannenberg.com

Dimensions 130 LED Lights 25 80 disruption prepared M20 39 37 113 47 mounting screw e.g. M4 x 20 Additional mounting possible via external lugs (included). disruption prepared M20/M32 113 130 mounting holes Operating modes S1 1 2 3 Selection via internal DIP switch OFF OFF OFF OFF OFF OFF ON all-round light 2.5 Hz OFF ON OFF continuous light OFF ON ON blinking light 1.5 Hz ON OFF OFF fl ashing light 1 Hz ON OFF ON all-round light 2.5 Hz ON ON OFF continuous light ON ON ON blinking light 1.5 Hz S1 - X1 - Selection via 1 1 2 3 4 external control (S1-2 = OFF, S1-3 = OFF) OFF -/N +/L OFF (standby) OFF -/N +/L +/L all-round light 2.5 Hz OFF -/N +/L +/L continuous light OFF -/N +/L +/L +/L blinking light 1.5 Hz ON -/N +/L fl ashing light 1 Hz ON -/N +/L +/L all-round light 2.5 Hz ON -/N +/L +/L continuous light ON -/N +/L +/L +/L blinking light 1.5 Hz S1 - X1 - Selection via BAV option 1 1 2 3 4 (24 V AC/DC only) (S1-2 = OFF, S1-3 = OFF) OFF -/N +/L all-round light 2.5 Hz OFF -/N +/L continuous light OFF -/N +/L +/L blinking light 1.5 Hz ON -/N +/L fl ashing light 1 Hz ON -/N +/L all-round light 2.5 Hz ON -/N +/L continuous light ON -/N +/L +/L blinking light 1.5 Hz Ordering details Article numbers Quadro-LED Flex Lens colour Rated voltage 230 V AC/DC 24 V AC/DC yellow 211 04 64 3 000 211 04 63 3 000 amber 211 04 64 4 000 211 04 63 4 000 red 211 04 64 5 000 211 04 63 5 000 Article numbers for other colours on request Options / Accessories GOST Conformity to standards The visual characteristics of LED lights conform to the European standard DIN EN 842: Machine safety - visual alarm signals. Requirements contained in the DIN EN 981 standard: Machine safety - system of acoustic and visual alarm and information signals, can be fulfi lled. The colours red for the emergency signal and yellow for the warning signal conform to the requirements of IEC 73 / DIN EN 60073 / VDE 0199: Coding of display devices and control elements using colours and supplementary means. References to visual alarm devices can be found in the following standards: EN 60825-1 Radiation safety of laser devices, identical to IEC 825 and DIN-VDE 0837 DIN EN 54 Fire alarm systems DIN 54113-2 Radiation protection regulations for the technical operation of X-ray equipment up to 500 kv Further technical information can be found on our website at www.pfannenberg.com 75

VISUAL SIGNALING DEVICES LED CONTINUOUS LIGHT PD 2100-LED Machine lights in an elegant pyramid design, equipped with LED light source for extremely long service life (> 50,000 hrs) vibration/shock-resistant low power consumption minimised maintenance costs non-compromising safety outstanding illumination of the coloured lens due to scattering lens r = 4 m Covering distance as per EN 54 IP 55 Protection system + 55 C - 25 C Operating temperature Electrical data PD 2100-LED Rated voltage 230 V AC 115 V AC 24 V AC/DC Rated frequency 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz / DC Operating range ± 10% ± 10% Nominal current consumption 12 ma 24 ma AC: 18 27 V DC: 19 30 V AC: 115 ma DC: 65 ma Mechanical data PD 2100-LED Light source LED Light intensity (DIN 5037) 1 5 cd Lens colours clear, white, yellow, amber, red, green, blue Operating temperature - 25 C... + 55 C Storage temperature - 40 C... + 80 C Relative humidity 90% Protection system according to EN 60529 IP 55 (if mounted vertically/horizontally) Protection class II Duty cycle 100% Service life of light source > 50,000 hrs lens polycarbonate (PC) Material housing ABS, light grey similar to RAL 7035 baseplate ABS, light grey similar to RAL 7035 Cable entry M20 x 1.5, either at the side or underneath Connecting terminals fi ne wire 0.14 2.5 mm 2 Weight 1 with a clear lens AC AC/DC 380 g 270 g 76 www.pfannenberg.com

Dimensions 2.5 7 49 128 LED Lights 166.2 111.2 Mounting holes 125 ±0.1 Ø max. 6.2 28-0.5 M20 Ø max. 6.2 85 ±0.1 Ø max. 6.2 Ordering details Article numbers PD 2100-LED Lens colour Rated voltage 230 V AC 24 V AC/DC clear 211 20 61 1 000 211 20 60 1 000 yellow 211 20 61 3 000 211 20 60 3 000 amber 211 20 61 4 000 211 20 60 4 000 red 211 20 61 5 000 211 20 60 5 000 green 211 20 61 6 000 211 20 60 6 000 blue 211 20 61 7 000 211 20 60 7 000 Options / Accessories See page 108 for further information GOST Article number: 287 10 50 0 040 Conformity to standards The visual characteristics of LED lights conform to the European standard DIN EN 842: Machine safety - visual alarm signals. Requirements contained in the DIN EN 981 standard: Machine safety - system of acoustic and visual alarm and information signals, can be fulfi lled. The colours red for the emergency signal and yellow for the warning signal conform to the requirements of IEC 73 / DIN EN 60073 / VDE 0199: Coding of display devices and control elements using colours and supplementary means. References to visual alarm devices can be found in the following standards: EN 60825-1 Radiation safety of laser devices, identical to IEC 825 and DIN-VDE 0837 DIN EN 54 Fire alarm systems DIN 54113-2 Radiation protection regulations for the technical operation of X-ray equipment up to 500 kv Further technical information can be found on our website at www.pfannenberg.com 77

VISUAL SIGNALING DEVICES SPECTRA COMPACT LED CONTINUOUS LIGHTS P 200 LDA / P 100 LDA (Ø 60 MM) Compact LED light series, also for installation where space is limited energy-saving and durable thanks to the use of maintenance-free LED technology large variety of mounting methods due to modular design principle: panel-mounted devices with convenient plug contact (P 100) surface-mounted devices for mounting directly or on a wall bracket or a tubular stand (P 200) durable, sturdy and functionally reliable due to the use of high-quality plastic optimum illumination due to prismatic coloured lens also for exposed installation locations by combining wall bracket and tubular stand high IP protection in any installation position r = 4 m Covering distance as per EN 54 IP 65 Protection system + 50 C - 25 C Operating temperature Electrical data P 200 LDA P 100 LDA Rated voltage 115 / 230 V AC 12 / 24 V DC 115 / 230 V AC 12 / 24 V DC Rated frequency 50 / 60 Hz 50 / 60 Hz Operating range 90 253 V 10 30 V 90 253 V 10 30 V Nominal current consumption 32 ma 80 ma 12 ma 80 ma Mechanical data P 200 LDA P 100 LDA Operating mode Light source Lens colours Lens type LED continuous light 9 high output LEDs yellow, amber, red, green, blue prismatic Operating temperature - 25 C... + 50 C Relative humidity 90% @ + 20 C Protection system according to EN 60529 IP 65 Service life of light source Material > 50,000 hrs polycarbonate (PC), UL 94 VO f1 Design bayonet with anti-tamper locking screw Mounting surface mounting (wall bracket and tubular stand available as accessories) panel-mounting: Ø 37.5 mm (PG29) Connecting terminals screw terminals 1.5 mm 2 screw terminals 1.5 mm 2 pluggable Weight 78 g 93 g 78 www.pfannenberg.com

Dimensions P 200 LDA P 100 LDA 25 35.5 65.5 LED Lights Ø 60 plug terminal connector Panel cut-out 21.23 37.5 16 thread PG29 25 80 Ø 60 17.5 36 mounting holes 2 x Ø 4.5 mm 15 cable entry Ø 8 mm Ordering details Article numbers P 200 LDA P 100 LDA Lens colour Rated voltage 115 / 230 V AC 12 / 24 V DC 115 / 230 V AC 12 / 24 V DC yellow 213 28 64 3 000 213 28 63 3 000 213 18 64 3 000 213 18 63 3 000 amber 213 28 64 4 000 213 28 63 4 000 213 18 64 4 000 213 18 63 4 000 red 213 28 64 5 000 213 28 63 5 000 213 18 64 5 000 213 18 63 5 000 Article numbers for other colours on request Options / Accessories Wall bracket only for P 200 LDA Tubular stand 137 mm only for P 200 LDA Wall holder only in combination with tubular stand See pages 106/107 for further information GOST Article number: 213 90 00 0 000 Article number: 213 91 00 0 000 Article number: 282 50 20 0 000 Conformity to standards The visual characteristics of LED lights conform to the European standard DIN EN 842: Machine safety - visual alarm signals. Requirements contained in the DIN EN 981 standard: Machine safety - system of acoustic and visual alarm and information signals, can be fulfi lled. The colours red for the emergency signal and yellow for the warning signal conform to the requirements of IEC 73 / DIN EN 60073 / VDE 0199: Coding of display devices and control elements using colours and supplementary means. References to visual alarm devices can be found in the following standards: EN 60825-1 Radiation safety of laser devices, identical to IEC 825 and DIN-VDE 0837 DIN EN 54 Fire alarm systems DIN 54113-2 Radiation protection regulations for the technical operation of X-ray equipment up to 500 kv Further technical information can be found on our website at www.pfannenberg.com 79

VISUAL SIGNALING DEVICES TRAFFIC LIGHT Quadro LED-TL IP 66 IK 08 + 55 C - 30 C Bright LED signal lights for traffi c light applications, e.g. for - traffic routing in non-public areas - conveyer and storage systems - crane safety (see also Regulations and standards for crane applications, page 81) - container handling systems extraordinary housing protection (IP 66, IK 08 and UV-protected PC housing) and innovative LED technology provide for very bright signals, long service lives and reliable operation mounted using external lugs or internal holes that do not impair the IP protection; mounting can be performed in any direction preassembled as traffi c light and ready to connect also available as non-preassembled version optionally with integrated light sensor for optimal adaptation to the ambient light (glare avoidance) Protection system Impact-proof housing Operating temperature Light sensor (optional) Electrical data Quadro LED-TL Rated voltage 115 / 230 V AC 24 V DC Rated frequency 50 / 60 Hz Operating range 85 265 V 10 30 V Max. current consumption 60 ma / 30 ma 1.06 A Mechanical data Quadro LED-TL Operating mode LED continuous light Light source high output LED array Light intensity (DIN 5037) > 80 cd Lens colours red / yellow / green Operating temperature - 30 C... + 55 C Storage temperature - 40 C... + 70 C Relative humidity 95% Protection system according to EN 60529 IP 66; IK 08 (EN 50102), mounting arbitrary Duty cycle 100% Service life of light source > 50,000 hrs Material lens polycarbonate (PC), UV-resistant housing polycarbonate (PC), UV-resistant, RAL 7035 Cable entry M20/M32 sideways, other imprints prepared Connecting terminals cage clamp terminal 0.08 2.5 mm 2 (in the red light) Mounting external lugs or internal holes Weight 1.32 kg 80 www.pfannenberg.com

Dimensions 3 green 2 yellow 1 red 130 LED Lights 19.5 113.5 4 x ø 4.5 M20 x 1.5 130 396 DIN-EN 13000:2004-09 Cranes truck-mounted cranes DIN-EN 14439:2006 Safety rotating tower cranes Regulations and standards for crane applications Visual warning to the driver (EN 842) in the case of Visual warning by the crane driver (EN 457) to persons in the vicinity in the case of Visual warning to the driver (EN 842) in the case of - approaching the load capacity (at 90-98.5% of the permissible load capacity) - triggering of the overload safety system - overriding of the overload safety system - remote control green, continuous light - anti-collision white, blinking light - rotating (in some cases when required by local authorities) green, blinking light - approaching the load capacity (at 90-95% of the permissible load capacity) yellow, continuous light - wind warning and alarm yellow, blinking light and red, blinking light Ordering details Article numbers Quadro LED-TL Quadro LED-TLi (with light sensor) Lens colour Rated voltage 115/230 V AC 24 V DC 115/230 V AC 24 V DC red / yellow / green 211 06 64 0 008 211 06 63 0 008 211 07 64 0 008 211 07 63 0 008 yellow 211 06 64 3 000 211 06 63 3 000 211 07 64 3 000 211 07 63 3 000 red 211 06 64 5 000 211 06 63 5 000 211 07 64 5 000 211 07 63 5 000 green 211 06 64 6 000 211 06 63 6 000 211 07 64 6 000 211 07 63 6 000 Article numbers for other combinations on request Options / Accessories Enclosure fitting Article number: 281 12 00 0 003 Conformity to standards The visual characteristics of LED lights conform to the European standard DIN EN 842: Machine safety - visual alarm signals. Requirements contained in the DIN EN 981 standard: Machine safety - system of acoustic and visual alarm and information signals, can be fulfi lled. The colours red for the emergency signal and yellow for the warning signal conform to the requirements of IEC 73 / DIN EN 60073 / VDE 0199: Coding of display devices and control elements using colours and supplementary means. References to visual alarm devices can be found in the following standards: EN 60825-1 Radiation safety of laser devices, identical to IEC 825 and DIN-VDE 0837 DIN EN 54 Fire alarm systems DIN 54113-2 Radiation protection regulations for the technical operation of X-ray equipment up to 500 kv Further technical information can be found on our website at www.pfannenberg.com 81

VISUAL SIGNALING DEVICES SPECTRA TRAFFIC LIGHTS P 450 TLA (Ø 140 MM) / P 350 TLA (Ø 100 MM) P 450 TLA P 350 TLA Signal lights for traffi c light applications simple to combine for horizontal or vertical confi guration convenient electrical connection of combined traffi c lights safe and maintenance-free even under the infl uence of extreme vibration thanks to LED technology clear signalling even in extremely bright surroundings thanks to the use of clear lenses stable fi xing bracket for fl exible alignment and mounting (optional) durable, sturdy and functionally reliable due to the use of high-quality plastic high signaling effect due to prismatic coloured lens glare protection adjustable to suit local conditions high IP protection in any installation position connecting piece for traffi c light combinations included r = 23 m r = 10.5m IP 65 + 50 C - 25 C Covering distance as per EN 54 Covering distance as per EN 54 Protection system Operating temperature Electrical data P 450 TLA P 350 TLA Rated voltage 115 / 230 V AC 12 / 24 V DC 115 / 230 V AC 12 / 24 V DC Operating range 90 253 V 10 30 V 90 253 V 10 30 V Nominal current consumption 15 40 ma 175 ma 10 40 ma 140 ma Mechanical data P 450 TLA P 350 TLA Operating mode LED continuous light LED continuous light Light source high output LED array Light intensity (DIN 5037) 60 cd 45 cd Lens colour Operating temperature - 25 C... + 50 C Relative humidity 90% @ + 20 C Protection system according to EN 60529 IP 65 Duty cycle 100% Service life of light source > 50,000 hrs Material Design Mounting clear polycarbonate (PC), UL 94 VO f1 bayonet with anti-tamper locking screw surface mounting (wall bracket available as accessories) Connecting terminals screw terminals 2 x 1.5 mm 2 screw terminals 2 x 1.5 mm 2 Cable entry 1 x 5-7 mm push through grommet (bottom side); 2 x M20 cable entries sideways (incl. connecting piece) 1 x 5-7 mm push through grommet; 2 x M20 cable entries (incl. connecting piece) Weight 410 g 230 g 82 www.pfannenberg.com

Dimensions P 450 TLA P 350 TLA 20 37 177 140 LED Lights Ø 140 57 20 cable entry M20 Ø 100 cable entry M20 55 27 mounting holes 3 x Ø 5.4 mm 120 27.5 46,5 mounting holes 2 x Ø 5.4 mm cable entry Ø 5-7 mm 120 Ø 140 cable entry Ø 5-7 mm 60 75 25 70 Ordering details Article numbers P 450 TLA P 350 TLA Lens colour Rated voltage 115 / 230 V AC 12 / 24 V DC 115 / 230 V AC 12 / 24 V DC amber 213 55 64 4 000 213 55 63 4 000 213 52 64 4 000 213 52 63 4 000 red 213 55 64 5 000 213 55 63 5 000 213 52 64 5 000 213 52 63 5 000 green 213 55 64 6 000 213 55 63 6 000 213 52 64 6 000 213 52 63 6 000 Options / Accessories Wall bracket for single mounting P 450 Wall bracket for single mounting P 350 Wall bracketset for combinations of 2 or 3 P 450 Wall bracketset for combinations of 2 or 3 P 350 See page 107 for further information GOST Article number: 213 99 00 0 000 Article number: 213 98 00 0 000 Article number: 213 97 00 0 000 Article number: 213 96 00 0 000 Further technical information can be found on our website at www.pfannenberg.com 83

VISUAL SIGNALING DEVICES CONTINUOUS LED PANEL MOUNT INDICATOR P 22 D BLINKING LED PANEL MOUNT INDICATOR P 22 DFS Indicator lamps for 22.5 mm mounting hole guaranteed high protection class (IP 65) to the housing superior shape, hence high signaling effect on all sides optimum illumination through the use of multi-chip LED array easy to mount labels holders available as accessories simple electrical connection by means of screw terminals IP 65 Protection system + 50 C - 25 C Operating temperature Electrical data P 22 D red / amber Rated voltage 230 V AC 115 V AC 48 V AC/DC 24 V AC/DC12 V AC/DC Nominal current consumption 25 ma 25 ma 20 ma 80 ma80 ma Electrical data P 22 D white / green / blue Rated voltage 230 V AC 115 V AC 48 V AC/DC 24 V AC/DC12 V AC/DC Nominal current consumption 25 ma 25 ma 20 ma 20 ma20 ma Electrical data P 22 DFS Rated voltage 230 V AC 115 V AC 48 V AC/DC 24 V AC/DC Nominal current consumption 15 30 ma Mechanical data P 22 D P 22 DFS Operating mode continuous light 1 Hz blinking light Light sourceled array Lens colours white, amber, red, green, blue red Operating temperature - 25 C... + 50 C Storage temperature 90% @ + 20 C Protection system according to EN 60529 IP 65 (to housing) Service life of light source > 50,000 hrs Mounting panel-mounting: Ø 22.5 mm Connecting terminals screw terminals 1.5 mm 2 Weight 90 g 84 www.pfannenberg.com

Dimensions Panel cut-out P 22 D Ø 29 13 39 max. 7 39 LED Lights 52 22.5 22 P 22 DFS Ø 29 49 13 max. 7 49 62 22.5 22 Ordering details Article numbers P 22 D Lens colour Rated voltage 230 V AC 115 V AC 48 V AC/DC 24 V AC/DC12 V AC/DC white 232 73 10 2 000 232 73 15 2 000 232 73 70 2 000 232 73 80 2 000 232 73 85 2 000 amber 232 73 10 4 000 232 73 15 4 000 232 73 70 4 000 232 73 80 4 000 232 73 85 4 000 red 232 73 10 5 000 232 73 15 5 000 232 73 70 5 000 232 73 80 5 000 232 73 85 5 000 green 232 73 10 6 000 232 73 15 6 000 232 73 70 6 000 232 73 80 6 000 232 73 85 6 000 blue 232 73 10 7 000 232 73 15 7 000 232 73 70 7 000 232 73 80 7 000 232 73 85 7 000 Article numbers P 22 DFS Lens colour Rated voltage 230 V AC 115 V AC 48 V AC/DC 24 V AC/DC red 232 71 10 5 000 232 71 15 5 000 232 71 70 5 000 232 71 80 5 000 Options / Accessories GOST Label holder Article number: 232 92 00 0 000 25 x 10 mm Label holder Article number: 232 91 00 0 000 25 x 18 mm Further technical information can be found on our website at www.pfannenberg.com 85

VISUAL SIGNALING DEVICES CONTINUOUS LIGHT PD 2100 Status lights for universal use machine light in an elegant pyramid design r = 6 m Covering distance as per EN 54 IP 55 Protection system + 32 C - 40 C Operating temperature Electrical data PD 2100 Rated voltage max. 250 V Power consumption max. 15 W * * light source not included Mechanical data PD 2100 Operating mode continuous light Light source BA15d, E14 Light power max. 15 W Lens colours clear, yellow, amber, red, green, blue Operating temperature - 40 C... + 32 C Storage temperature - 40 C... + 80 C Relative humidity 90% Protection system according to EN 60529 IP 55 (if mounted vertically/horizontally) Duty cycle 100% Material lens polycarbonate (PC) housing ABS, light grey similar to RAL 7035, (optionally graphite grey RAL 7024) Cable entry M20 x 1.5 either at the side or underneath Weight 250 g 86 www.pfannenberg.com

Dimensions 2.5 7 49 128 Continuous Lights 166.2 111.2 Mounting holes 125 ±0.1 Ø max. 6.2 28-0.5 M20 Ø max. 6.2 85 ±0.1 Ø max. 6.2 Ordering details Article numbers PD 2100 Lens colour Socket BA15d E14 clear 211 20 30 1 000 211 20 10 1 000 yellow 211 20 30 3 000 211 20 10 3 000 amber 211 20 30 4 000 211 20 10 4 000 red 211 20 30 5 000 211 20 10 5 000 green 211 20 30 6 000 211 20 10 6 000 blue 211 20 30 7 000 211 20 10 7 000 * please order light bulb separately Options / Accessories See pages 105/108 for further information GOST Light source Article number: 287 10 50 0 042 Conformity to standards The visual characteristics of continuous lights conform to the European standard DIN EN 842: Machine safety - visual alarm signals. Requirements contained in the DIN EN 981 standard: Machine safety - system of acoustic and visual alarm and information signals, can be fulfi lled. The colours red for the emergency signal and yellow for the warning signal conform to the requirements of IEC 73 / DIN EN 60073 / VDE 0199: Coding of display devices and control elements using colours and supplementary means. References to visual alarm devices can be found in the following standards: EN 60825-1 Radiation safety of laser devices, identical to IEC 825 and DIN-VDE 0837 DIN EN 54 Fire alarm systems DIN 54113-2 Radiation protection regulations for the technical operation of X-ray equipment up to 500 kv Further technical information can be found on our website at www.pfannenberg.com 87

VISUAL SIGNALING DEVICES SPECTRA TRAFFIC LIGHTS P 450 TSB / P 450 TDB (Ø 140 MM) / P 350 TSB (Ø 100 MM) Signal lights for traffi c light applications simple to combine for horizontal or vertical confi guration also for safety-relevant applications through use of two light sources (TDB) stable fi xing bracket for fl exible alignment and mounting (optional) durable, sturdy and functionally reliable due to the use of high-quality plastic high signaling effect due to prismatic coloured lens glare protection adjustable to suit local conditions high IP protection in any installation position connecting piece for traffi c light combinations included P 450 TSB P 450 TDB P 350 TSB r = 10 m r = 6 m r = 6 m IP 65 + 50 C - 25 C Covering distance as per EN 54 Covering distance as per EN 54 Covering distance as per EN 54 Protection system Operating temperature Electrical data P 450 TSB P 450 TDB P 350 TSB Rated voltage 12 250 V * 12 250 V * 12 250 V * Power consumption 25 W 2 x 15 W 15 W * light source not included Mechanical data P 450 TSB P 450 TDB P 350 TSB Operating mode continuous light continuous light (redundant) continuous light Light source fi lament lamp E27 2 x fi lament lamp E14 fi lament lamp E14 Lens colours amber, red, green Operating temperature - 25 C... + 50 C Relative humidity 90% @ + 20 C Protection system according to EN 60529 IP 65 Material Design Mounting Cable entry 1 x 5-7 mm push through grommet; 1 x M20 cable entry (incl. connecting piece) polycarbonate (PC), UL 94 VO f1 bayonet with anti-tamper locking screw surface mounting (wall bracket available as accessories) 1 x 5-7 mm push through grommet (bottom side); 2 x M20 cable entries sideways (incl. connecting piece) Connecting terminals screw terminals 1.5 mm 2 1 x 5-7 mm push through grommet; 1 x M20 cable entry (incl. connecting piece) Weight 395 g 380 g 210 g 88 www.pfannenberg.com

Dimensions P 450 TSB / P 450 TDB P 350 TSB 20 20 57 37 177 140 Continuous Lights Ø 140 cable entry 2 x M20 Ø 100 cable entry M20 mounting holes 3 x Ø 5.4 mm 120 27.5 55 27 46,5 mounting holes 2 x Ø 5.4 mm cable entry Ø 5-7 mm 120 Ø 140 cable entry Ø 5-7 mm 60 75 25 70 Ordering details Article numbers P 450 TSB P 450 TDB P 350 TSB Lens colour Rated voltage 12 250 V * 12 250 V * 12 250 V * amber 213 54 65 4 000 213 53 62 4 000 213 51 62 4 000 red 213 54 65 5 000 213 53 62 5 000 213 51 62 5 000 green 213 54 65 6 000 213 53 62 6 000 213 51 62 6 000 * please order light bulb separately Options / Accessories Wall bracket for single mounting P 450 Wall bracket for single mounting P 350 Wall bracketset for combinations of 2 or 3 P 450 Wall bracketset for combinations of 2 or 3 P 350 See pages 107/108 for further information GOST Article number: 213 99 00 0 000 Article number: 213 98 00 0 000 Article number: 213 97 00 0 000 Article number: 213 96 00 0 000 Light source Conformity to standards The visual characteristics of continuous lights conform to the European standard DIN EN 842: Machine safety - visual alarm signals. Requirements contained in the DIN EN 981 standard: Machine safety - system of acoustic and visual alarm and information signals, can be fulfi lled. The colours red for the emergency signal and yellow for the warning signal conform to the requirements of IEC 73 / DIN EN 60073 / VDE 0199: Coding of display devices and control elements using colours and supplementary means. References to visual alarm devices can be found in the following standards: EN 60825-1 Radiation safety of laser devices, identical to IEC 825 and DIN-VDE 0837 DIN EN 54 Fire alarm systems DIN 54113-2 Radiation protection regulations for the technical operation of X-ray equipment up to 500 kv Further technical information can be found on our website at www.pfannenberg.com 89

VISUAL SIGNALING DEVICES SPECTRA ROTATING MIRROR LIGHTS P 400 RTH (Ø 140 MM) / P 300 RTH (Ø 100 MM) Sturdy rotating mirror lights, also for installation where space is limited very high signaling effect due to the use of halogen lamps large variety of mounting methods due to modular design principle: surface-mounted devices for mounting directly or on a wall bracket or a tubular stand also for exposed installation locations through combination of wall bracket and tubular stand cable entry at the side or through the base of the housing durable, sturdy and functionally reliable due to the use of high-quality plastic P 400 RTH P 300 RTH r = 20 m r = 12.5m IP 65 + 50 C - 25 C Covering distance as per EN 54 Protection system Operating temperature Electrical data P 400 RTH P 300 RTH Rated voltage 230 V AC 115 V AC 24 V DC 12 V DC 230 V AC 115 V AC 24 V DC 12 V DC Rated frequency 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz Nominal current consumption 186 ma 338 ma 1.54 A 3 A 117 ma 216 ma 0.91 A 1.72 A Capacity of light source 40 W 40 W 35 W 35 W 25 W 25 W 20 W 20 W Mechanical data P 400 RTH P 300 RTH Operating mode halogen rotating mirror light Light source halogen lamp G6.35 / GY6.35 Rotation Lens colours Lens type approx. 180 rpm clear, yellow, amber, red, green, blue plain, transparent Operating temperature - 25 C... + 50 C Relative humidity 90% @ + 20 C Protection system according to EN 60529 IP 65 Duty cycle 100% Lebensdauer Material Design Mounting Installation position > 5,000 hrs polycarbonate (PC), UL 94 VO f1 bayonet with anti-tamper locking screw surface mounting (wall bracket and tubular stand available as accessories) arbitrary Connecting terminals screw terminals 1.5 mm 2 Cable entry 1 x 5-7 mm push through grommet (bottom side); 1 x M20 cable entry sideways Weight 578 g 370 g 90 www.pfannenberg.com

Dimensions P 400 RTH P 300 RTH 220 cable entry 2 x M20 150 cable entry M20 20 58 20 Rotating Mirror Lights 37 Ø 140 Ø 100 cable entry Ø 5-7 mm 120 mounting holes 3 x Ø 5.4 mm 27 mounting holes 2 x Ø 5.4 mm 25 Ø 110 cable entry Ø 5-7 mm 27.5 55 47 85 45 60 Ordering details Article numbers P 400 RTH P 300 RTH Lens colour Rated voltage 230 V AC 115 V AC 24 V DC 12 V DC 230 V AC 115 V AC 24 V DC 12 V DC yellow21347103000 2134715300021347803000 2134785300021337103000 2133715300021337803000 21337853000 amber21347104000 2134715400021347804000 2134785400021337104000 2133715400021337804000 21337854000 red21347105000 2134715500021347805000 2134785500021337105000 2133715500021337805000 21337855000 Article numbers for other colours on request Options / Accessories Wall bracket for P 400 Wall bracket for P 300 Tubular stand 145 mm for P 400 Tubular stand 140 mm for P 300 Wall holder only in combination with tubular stand See pages 106/107 for further information GOST Article number: 213 94 00 0 000 Article number: 213 92 00 0 000 Article number: 213 95 00 0 000 Article number: 213 93 00 0 000 Article number: 282 50 20 0 000 Conformity to standards The visual characteristics of rotating mirror lights conform to the European standard DIN EN 842: Machine safety - visual alarm signals. Requirements contained in the DIN EN 981 standard: Machine safety - system of acoustic and visual alarm and information signals, can be fulfi lled. The colours red for the emergency signal and yellow for the warning signal conform to the requirements of IEC 73 / DIN EN 60073 / VDE 0199: Coding of display devices and control elements using colours and supplementary means. References to visual alarm devices can be found in the following standards: EN 60825-1 Radiation safety of laser devices, identical to IEC 825 and DIN-VDE 0837 DIN EN 54 Fire alarm systems DIN 54113-2 Radiation protection regulations for the technical operation of X-ray equipment up to 500 kv Further technical information can be found on our website at www.pfannenberg.com 91

VISUAL SIGNALING DEVICES FLASHING LIGHT 13 J Quadro S-M-Flex Proven tunnel safety light; conforms to the guideline of the Swiss Federal Highways Authority: Signaling systems of safety devices in tunnels synchronised fl ashing of up to 10 beacons in series with no additional controller initial current limited to below 1 A integrated function monitoring with fault message contact variable brightness and fl ash frequency settings on-site on the device use of double-pole terminals for the simple connection of parallel operated lights r = 19 m IP 66 IP 67 IK 08 I lim t Sync + 55 C - 25 C 10 Years Covering distance as per EN 54 Protection system Protection system Impact-proof housing Inrush current limited to < 1A Operating temperature Warranty Electrical data Quadro S-M-Flex Rated voltage 230 V AC 115 V AC Rated frequency 50 / 60 Hz 50 / 60 Hz Operating range 195 253 V 95 127 V Nominal current consumption 250 ma (1 Hz / 13 J) 350 ma (1 Hz / 13 J) Initial current limited to < 1 A / 10 ms Alarm output 230 V / 80 ma Mechanical data Quadro S-M-Flex Flash rate adjustable (1 Hz = 60 fl ashes/min. factory setting) Flash energy max. 13 J Light intensity (DIN 5037) 1 140 cd Lens colours clear, white, yellow, amber, red, green, blue Operating temperature - 25 C... + 55 C Storage temperature - 40 C... + 70 C Relative humidity 100% Protection system according to EN 60529 IP 66, IP 67; mounting arbitrary Impact resistance as per EN 50102 IK 08 Protection class II Duty cycle 100% Service life of the flash tube light emission still 70% after 12,000,000 fl ashes Material lens polycarbonate (PC) housing polycarbonate (PC), RAL 7035 Connecting terminals cage clamp terminal 0.08-2.5 mm 2 Cable entry (prepared) Mounting Weight 2 x M20 x 1.5 sideways external lugs 113 x 153 mm M5 or 127.1 x 127.1 mm M5 internal holes 113 x 113 mm 600 g 1 with a clear lens 92 www.pfannenberg.com

Dimensions Fault message contact 130 80 blanking plug M20 x 1.5 113 Functionmonitored Lights 25 115 X1 S1 X2 alarm output 130 mounting screw e.g. 4 x M4 x 20 M20 x 1.5 cable connection Additional mounting possible via external lugs (included). DIP switch setting Setting 4 3 2 1 Frequency (Hz) Flash energy (J) 1 13 ON 1.33 13 ON 0.5 13 ON ON 0.1 13 ON 1 7.5 ON ON 2 7.5 ON ON 0.5 7.5 ON ON ON 0.1 7.5 ON 1.5 11 ON ON 1.75 10 ON ON 2.5 7.5 ON ON ON 7.5 ON ON 7.5 ON ON ON 7.5 ON ON ON repeating 7.5 ON ON ON ON only one fl ash 13 without synchronisation 0.66 7.5 Ordering details Article numbers Quadro S-M-Flex Lens colour Rated voltage 230 V AC clear 210 42 10 1 179 yellow 210 42 10 3 179 amber 210 42 10 4 179 red 210 42 10 5 179 Article numbers for other colours and voltages on request Options / Accessories GOST Conformity to standards The visual characteristics of fl ashing lights conform to the European standard DIN EN 842: Machine safety - visual alarm signals. Requirements contained in the DIN EN 981 standard: Machine safety - system of acoustic and visual alarm and information signals, can be fulfi lled. The colours red for the emergency signal and yellow for the warning signal conform to the requirements of IEC 73 / DIN EN 60073 / VDE 0199: Coding of display devices and control elements using colours and supplementary means. References to visual alarm devices can be found in the following standards: EN 60825-1 Radiation safety of laser devices, identical to IEC 825 and DIN-VDE 0837 DIN EN 54 Fire alarm systems DIN 54113-2 Radiation protection regulations for the technical operation of X-ray equipment up to 500 kv Further technical information can be found on our website at www.pfannenberg.com 93

VISUAL SIGNALING DEVICES FLASHING WARNING LIGHTS 5 J WBL-M / WBS-M Flashing light with integrated fl ash monitoring and fault message contact for systems with safety-relevant applications, such as X-ray and laser equipment housing and fi xing bracket made of sturdy anodised aluminium also available with GL approval ideally suited for tough industrial environments fl ash tube secured by additional steel clamp impact-proof lens r = 11 m Covering distance as per EN 54 IP 54 Protection system + 55 C - 20 C Operating temperature Electrical data WBL-M WBS-M Rated voltage 230 V AC 42 V AC 48 V DC 24 V DC 12 V DC Rated frequency 50 / 60 Hz 50 / 60 Hz Operating range 185 242 V 37 47 V 40 57 V 18 35 V 10 15 V Nominal current consumption 0.07 A 0.5 A 0.18 W 0.25 A 0.6 A Switching capacity of the faiure indication Switching voltage Switching current max. 250 V AC max. 3 A Mechanical data WBL-M WBS-M Flash rate 1 Hz = 60 fl ashes/min. Flash energy 5 J Light intensity (DIN 5037) 1 44 cd Lens colours clear, white, yellow, amber, red, green, blue Operating temperature - 20 C... + 55 C Storage temperature - 40 C... + 70 C Relative humidity 90% Protection system according to EN 60529 IP 54 (vertical mounting) Duty cycle 100% Service life of the flash tube light emission still 70% after 8,000,000 fl ashes lens polycarbonate (PC) Material housing aluminium (Al Mg Si 1), yellow anodised base polycarbonate (PC) with fi bre glass Cable entry M20 x 1.5 Connecting terminals single wire 0.5 2.5 mm 2, fi ne wire 0.5 1.5 mm 2, with cable end sleeves DIN 46228/1 Weight 700 g 1 with a clear lens 94 www.pfannenberg.com

Dimensions 242 Functionmonitored Lights Ø 80 Ø 6.5 40 84 50 65 M20 Ordering details Article numbers WBL-M WBS-M Lens colour Rated voltage 230 V AC 115 V AC 24 V DC yellow 210 03 10 3 156 210 03 16 3 156 210 03 80 3 156 amber 210 03 10 4 156 210 03 16 4 156 210 03 80 4 156 red 210 03 10 5 156 210 03 16 5 156 210 03 80 5 156 Article numbers for other colours and voltages on request Options / Accessories I lim t See page 105 for further information GL GOST Article number: 287 10 50 0 042 Conformity to standards The visual characteristics of fl ashing lights conform to the European standard DIN EN 842: Machine safety - visual alarm signals. Requirements contained in the DIN EN 981 standard: Machine safety - system of acoustic and visual alarm and information signals, can be fulfi lled. The colours red for the emergency signal and yellow for the warning signal conform to the requirements of IEC 73 / DIN EN 60073 / VDE 0199: Coding of display devices and control elements using colours and supplementary means. References to visual alarm devices can be found in the following standards: EN 60825-1 Radiation safety of laser devices, identical to IEC 825 and DIN-VDE 0837 DIN EN 54 Fire alarm systems DIN 54113-2 Radiation protection regulations for the technical operation of X-ray equipment up to 500 kv Further technical information can be found on our website at www.pfannenberg.com 95

VISUAL SIGNALING DEVICES ALL-ROUND FLASHING LIGHT PMF 2015-M Extremely bright due to 14 joules total fl ash energy of the impulse group and light bundling with fesnel lens, low power consumption (energy-saving) the function of the flashing light is monitored internally via an optical sensor and evaluation circuitry both sub-systems (flashing light and monitoring unit) have separate operating voltage connections the light is extremely failure-tolerant and carries type approval from the Swiss Ministry of Transport independent technical safety report within the definitions of EN 50129 exists r = 22 m Covering distance as per EN 54 IP 55 Protection system + 55 C - 30 C Operating temperature Electrical data PMF 2015-M Rated voltage Operating range Current fl ashing light consumption monitoring unit Alarm contact version contact switching current switching voltage max. switching power (AC) recommended minimum load 24 V DC 18 30 V 0.65 A 0.05 A positively driven contact (1 x NC, 1 x NO) max. 6 A max. 250 V AC 1,500 VA > 50 mw Mechanical data PMF 2015-M Operating mode double fl ash Light source xenon fl ash tube Flash rate of the main flash 1 Hz = 60 fl ashes/min. Flash energy of the main flash 7 J Light intensity (DIN 5037) 1 200 cd Lens colours clear, amber, red, green, blue Lens type lens with fresnel characteristic Beam angle vertical approx. 16 horizontal 360 Operating temperature - 30 C... + 55 C Storage temperature - 40 C... + 70 C Relative humidity 90% Protection system according to EN 60529 IP 55 (vertical mounting) Duty cycle 100% Service life of the flash tube light emission still 70% after 8,000,000 fl ashes Material lens polycarbonate (PC) housing bracket mounting: polycarbonate (PC) / direct mounting: acrylonitrile butadiene styrene (ABS) Cable entry bracket mounting M20 x 1.5 for cables 6.5 13.5 mm Connecting terminals 0.08 2.5 mm 2 1 with a clear lens 96 www.pfannenberg.com

Dimensions Bracket mounting Direct mounting Drilling template 1 (for M5 threaded bushing) 170.5 185 Ø 5.5 120 Ø 130 45 Functionmonitored Lights 120 M20 x 1.5 75 Ø 130 Ø 177 8.5 M5 threaded bushing Drilling template 2 diameter variable depending on cable entry 6.5 4 45 Ø 5.5 10 Ø 5.5 90 50 50 163 Two different drilling templates are available for fi xing the light (direct mounting). M5 x 8 threaded bushes are set into the base of the light for fi xing according to drilling template 1. Drilling template 2 allows the light to be fi xed using 4 through bolts or similar from above. Flash rate Energy single fl ash [J] 7 2 fl ashes, 120 fl ashes/min. pulse duration 0.25 s 3,5 1 2 3 4 t [s] Ordering details Article numbers PMF 2015-M bracket mounting Lens colour Rated voltage 24 V DC amber 210 07 80 4 012 red 210 07 80 5 012 Article numbers for other colours on request Options / Accessories GOST Conformity to standards The visual characteristics of fl ashing lights conform to the European standard DIN EN 842: Machine safety - visual alarm signals. Requirements contained in the DIN EN 981 standard: Machine safety - system of acoustic and visual alarm and information signals, can be fulfi lled. The colours red for the emergency signal and yellow for the warning signal conform to the requirements of IEC 73 / DIN EN 60073 / VDE 0199: Coding of display devices and control elements using colours and supplementary means. References to visual alarm devices can be found in the following standards: EN 60825-1 Radiation safety of laser devices, identical to IEC 825 and DIN-VDE 0837 DIN EN 54 Fire alarm systems DIN 54113-2 Radiation protection regulations for the technical operation of X-ray equipment up to 500 kv EN 50129:2003 Railway applications telecommunication technology, signalling technology and data processing systems safety-relevant electronic systems for signal technology EN 12352:2000 Traffi c routing systems, warning and safety lights class: L1 C red F3 O3 M0 T1 S3 Further technical information can be found on our website at www.pfannenberg.com 97

VISUAL SIGNALING DEVICES LED CONTINUOUS LIGHTS PD 2100-M-AS-i / PD 2100-LED-M Machine lights in an elegant pyramid design, equipped with LED light source for extremely long service life (> 50 000 hrs) vibration/shock-resistant low power consumption minimised maintenance costs non-compromising safety outstanding illumination of the coloured lens due to scattering lens integrated function monitoring with potential-free fault contact for safety-relevant applications, such as X-ray and laser equipment Additional for AS-i-Bus light: supplying of the light directly by bus system control and function monitoring directly via AS interface M-AS-i LED-M r = 4 m IP 55 + 45 C - 25 C + 55 C - 25 C Covering distance as per EN 54 Protection system Operating temperature Operating temperature Electrical data PD 2100-M-AS-i PD 2100-LED-M Rated voltage 28 V 230 V AC 24 V DC Nominal current consumption approx. 250 ma 12 ma 65 ma Rated frequency 50 / 60 Hz Operating range 26.5 32.6 V ± 10% 21 29 V Alarm output via AS-i Bus 230 V / 80 ma (MOS relay, R ON max. = 35 Ω) (NC) Mechanical data PD 2100-M-AS-i PD 2100-LED-M Operating mode continuous light Light source LED Light intensity (DIN 5037) 1 5 cd Lens colours clear, white, yellow, amber, red, green, blue Operating temperature - 25 C... + 45 C - 25 C... + 55 C Storage temperature - 40 C... + 70 C Relative humidity 90% Protection system according to EN 60529 IP 55 (if mounted vertically/horizontally) Protection class II Duty cycle 100% Service life of light source > 50,000 hrs lenspolycarbonate (PC) Material housing ABS, light grey similar to RAL 7035 baseplate ABS, light grey similar to RAL 7035 Cable entry M20 x 1.5, either at the side or underneath Connecting terminals fi ne wire 0.14 2.5 mm 2 M12 plug connector, 4-pole Pin 1 AS-i + Type of connection Pin 2 NC Pin 3 AS-i Pin 4 NC AS-i + Addressing socket DC jack, Ø 1.3 mm AS-i AS-i spezification AS-i 2.1, A/B capable EN 50295 Weight 300 g AC: 380 g / DC: 270 g 1 with a clear lens 98 www.pfannenberg.com

Dimensions PD 2100-M-AS-i PD 2100-LED-M 2.5 7 49 79 128 128 Functionmonitored Lights M12 111.2 166.2 11 166.2 Mounting holes PD 2100-M-AS-i PD 2100-LED-M Ø max. 6,4 Ø max. 6.2 28-0.5 125 ±0.1 Ø max. 6,4 Ø 24 85 M20 Ø max. 6.2 28 85 ±0.1 24 125 Ø max. 6,4 Ø max. 6.2 Ordering details Article numbers PD 2100-M-AS-i PD 2100-LED-M Lens colour Rated voltage 26.5 V 32.6 V 24 V DC white 211 20 50 2 004 yellow 211 20 60 3 005 red 211 20 50 5 004 211 20 60 5 005 Article numbers for other colours on request Options / Accessories See page 105 for further information GOST Article number: 287 10 50 0 040 Conformity to standards The visual characteristics of continuous lights conform to the European standard DIN EN 842: Machine safety - visual alarm signals. Requirements contained in the DIN EN 981 standard: Machine safety - system of acoustic and visual alarm and information signals, can be fulfi lled. The colours red for the emergency signal and yellow for the warning signal conform to the requirements of IEC 73 / DIN EN 60073 / VDE 0199: Coding of display devices and control elements using colours and supplementary means. References to visual alarm devices can be found in the following standards: EN 60825-1 Radiation safety of laser devices, identical to IEC 825 and DIN-VDE 0837 DIN EN 54 Fire alarm systems DIN 54113-2 Radiation protection regulations for the technical operation of X-ray equipment up to 500 kv Further technical information can be found on our website at www.pfannenberg.com 99

VISUAL SIGNALING DEVICES FLASHING LIGHT 10 J Quadro F12-SIL Integrated safety in sturdy Quadro-Design to signal dangerous situations in safety-relevant application such as process and plant safety, e.g. - leaks / gas warning - high-pressure / overfi lling and machine safety, e.g. as - start-up warning - muting indication - machine stop delay warning by means of integrated self-monitoring of the devices the normative required, regular inspection of warning devices is ensured the warning devices can be implemented in Safety Instrumented Systems (SIS) up to SIL 2/PLd We would be more than happy to provide all safety-technical key data. r = 17 m IP 66 IP 67 IK 08 + 55 C - 30 C 10 Years Covering distance as per EN 54 Protection system Protection system Impact-proof housing Operating temperature Warranty Electrical data Quadro F12-SIL Rated voltage 230 V AC 115 V AC 24 V DC Rated frequency 50 / 60 Hz 50 / 60 Hz Operating range 195 253 V 95 127 V 18 30 V Nominal current fl ashing light 250 ma 350 ma 700 ma consumption diagnostics channel 100 ma 100 ma 65 ma Alarm contact version positively driven contact (1 x NC, 1 x NO) contact switching current max. 6 A switching voltage max. 250 V AC max. switching power (AC) 1,500 VA recommended minimum load > 50 mw Mechanical data Quadro F12-SIL Flash rate 1 Hz = 60 fl ashes/min. Flash energy 10 J Light intensity (DIN 5037) 1 118 cd Lens colours clear, white, yellow, amber, red, green, blue Operating temperature - 30 C... + 55 C Storage temperature - 40 C... + 70 C Relative humidity 100% Protection system according to EN 60529 IP 66, IP 67, mounting arbitrary Impact resistance as per EN 50102 IK 08 Protection class II Duty cycle 100% Service life of the flash tube light emission still 70% after 8,000,000 fl ashes Material lens polycarbonate (PC) housing polycarbonate (PC), RAL 7035 Cable entry 2 x M20 bottom side / 2 x M20/M32 sideways Connecting terminals cage clamp terminal 0.08-2.5 mm 2 Mounting external lugs 113 x 153 mm M5 or 127.1 x 127.1 mm M5 internal holes 113 x 113 mm Weight 600 g 1 with a clear lens 100 www.pfannenberg.com

Dimensions 130 25 39 130 80 130 113 Safety-related Lights 47 2 x M20 (M32 prepared) 2 x M20 prepared 37 113 mounting holes Additional mounting possible via external lugs (included). Connection diagram 1 2 3 4 5 6 7 8 L/+ Operating voltage fl ashing light N/- Operating voltage fl ashing light L/+ Operating voltage monitoring channel N/- Operating voltage monitoring channel Alarm relay NO Alarm relay NO Alarm relay NC Alarm relay NC (mechanical safety relay, positively driven contacts, voltage rating 250V/6A minimum contact load 10mA/5V) Ordering details Article numbers Quadro F12-SIL Lens colour Rated voltage 230 V AC 24 V DC yellow 210 41 10 3 601 210 41 80 3 601 amber 210 41 10 4 601 210 41 80 4 601 red 210 41 10 5 601 210 41 80 5 601 Article numbers for other colours and voltages on request Options / Accessories GOST Conformity to standards The visual characteristics of fl ashing lights conform to the European standard DIN EN 842: Machine safety - visual alarm signals. Requirements contained in the DIN EN 981 standard: Machine safety - system of acoustic and visual alarm and information signals, can be fulfi lled. The colours red for the emergency signal and yellow for the warning signal conform to the requirements of IEC 73 / DIN EN 60073 / VDE 01990: Coding of display devices and control elements using colours and supplementary means. The visual alarms fulfill the requirements to the functional safety according to: EN 61508 Functional safety of electrical/electronic/programmable electronic safety-related systems EN 61511 Functional safety - Safety instrumented systems for the process industry sector The devices can be used in safety related control systems in accordance with the following standards: EN ISO 13849-1 Safety of machinery - Safety related parts of control systems part 1 EN 62061 Safety of machinery - Functional safety of electrical/electronic/programmable electronic safety-related systems Further technical information can be found on our website at www.pfannenberg.com 101

VISUAL SIGNALING DEVICES ALL-ROUND FLASHING LIGHT 10 J PMF 2015-SIL Extremely bright fl ashing light by light bundling with fesnel lens, low power consumption to signal dangerous situations in safety-relevant application such as process and plant safety, e.g. - leaks / gas warning - high-pressure / overfi lling and machine safety, e.g. as - start-up warning - muting indication - machine stop delay warning by means of integrated self-monitoring of the devices the normative required, regular inspection of warning devices is ensured the warning devices can be implemented in Safety Instrumented Systems (SIS) up to SIL 2/PLd We would be more than happy to provide all safety-technical key data. r = 22 m Covering distance as per EN 54 IP 55 Protection system + 55 C - 30 C Operating temperature Electrical data PMF 2015-SIL Rated voltage 230 V AC 24 V DC Rated frequency 50 / 60 Hz Operating range 195 253 V 18 30 V Nominal current fl ashing light 250 ma 700 ma consumption diagnostics channel 100 ma 65 ma Alarm contact version positively driven contact (1 x NC, 1 x NO) contact switching current max. 6 A switching voltage max. 250 V AC max. switching power (AC) 1,500 VA recommended minimum load > 50 mw Mechanical data PMF 2015-SIL Flash rate of the main flash 1 Hz = 60 fl ashes/min. Flash energy of the main flash10 J Light intensity (DIN 5037) 1 200 cd Lens colours clear, amber, red, green, blue Lens type lens with fresnel characteristic Beam angle vertical approx. 16 horizontal 360 Operating temperature - 30 C... + 55 C Storage temperature - 40 C... + 70 C Relative humidity 90% Protection system according to EN 60529 IP 55 (vertical mounting) Duty cycle 100% Service life of the flash tube light emission still 70% after 8,000,000 fl ashes Material lens polycarbonate (PC) housing bracket mounting: polycarbonate (PC) / direct mounting: acrylonitrile butadiene styrene (ABS) Cable entry bracket mounting M20 x 1.5 for cables 6.5-13,5 mm Connecting terminals single wire 0.5 2.5 mm 2, fi ne wire 0.5 1.5 mm 2, with cable end sleeves DIN 46228/1 Weight bracket mounting AC: 1.1 kg / DC: 1.2 kg direct mounting AC: 0.6 kg / DC: 0.7 kg 1 with a clear lens 102 www.pfannenberg.com

Dimensions Bracket mounting Direct mounting Drilling template 1 (for M5 threaded bushing) 170.5 185 Ø 5.5 120 Ø 130 Safety-related Lights M20 x 1.5 75 Ø 130 Ø 177 8.5 45 M5 threaded bushing 120 Drilling template 2 diameter variable depending on cable entry 6.5 4 Ø 5.5 10 Ø 5.5 90 50 45 163 50 Two different drilling templates are available for fi xing the light (direct mounting). M5 x 8 threaded bushes are set into the base of the light for fi xing according to drilling template 1. Drilling template 2 allows the light to be fi xed using 4 through bolts or similar from above. Connection diagram 1 2 3 4 5 6 7 8 L/+ Operating voltage fl ashing light N/- Operating voltage fl ashing light L/+ Operating voltage monitoring channel N/- Operating voltage monitoring channel Alarm relay NO Alarm relay NO Alarm relay NC Alarm relay NC (mechanical safety relay, positively driven contacts, voltage rating 250V/6A minimum contact load 10mA/5V) Ordering details Article numbers PMF 2015-SIL direct mounting PMF 2015-SIL bracket mounting Lens colour Rated voltage 230 V AC 24 V DC 230 V AC 24 V DC amber 210 07 10 4 601 210 07 80 4 601 210 07 10 4 611 210 07 80 4 611 red 210 07 10 5 601 210 07 80 5 601 210 07 10 5 611 210 07 80 5 611 Article numbers for other colours and voltages on request Options / Accessories GOST Conformity to standards The visual characteristics of fl ashing lights conform to the European standard DIN EN 842: Machine safety - visual alarm signals. Requirements contained in the DIN EN 981 standard: Machine safety - system of acoustic and visual alarm and information signals, can be fulfi lled. The colours red for the emergency signal and yellow for the warning signal conform to the requirements of IEC 73 / DIN EN 60073 / VDE 0199: Coding of display devices and control elements using colours and supplementary means. The visual alarms fulfill the requirements to the functional safety according to: EN 61508 Functional safety of electrical/electronic/programmable electronic safety-related systems EN 61511 Functional safety - Safety instrumented systems for the process industry sector The devices can be used in safety related control systems in accordance with the following standards: EN ISO 13849-1 Safety of machinery - Safety related parts of control systems part 1 EN 62061 Safety of machinery - Functional safety of electrical/electronic/programmable electronic safety-related systems Further technical information can be found on our website at www.pfannenberg.com 103

VISUAL SIGNALING DEVICES ACCESSORIES EXTERNAL FLASH MONITORING SYSTEM This device monitors the correct functioning of a fl ashing light by opto-electronic means. The fl ash from the light is fed via an optical fi bre to a phototransistor, which converts the optical impulse to an electrical impulse. The electronic circuit evaluates the pulse and its regular repetition. As soon as the operating voltage is applied, the evaluation relay closes the changeover contact. If the operating voltage fails, the relay opens immediately. This method of operation represents the fail-safe normally-closed circuit function and guarantees an alarm even if the operating voltage fails. On the other hand, the changeover contact serves to continue an alarm, e.g. in an failure message line, or the direct blocking of further machine processes. Electrical data External flash monitoring Rated voltage 230 V AC 12 V DC 24 V DC 48 V DC Rated frequency 50 / 60 Hz Operating range 198 242 V 11 15 V 16 34 V 38 52 V Nominal current consumption 0.001 A 0.05 A 0.05 A 0.05 A Mechanical data External flash monitoring Fibre optic cable 1 m Duty cycle 100% Switching capacity of the evaluation circuit max. 230 V AC: 2 A Operating temperature - 20 C... + 50 C Storage temperature - 40 C... + 50 C Relative humidity 90% Protection system according to EN 60529 IP 55 Material acrylonitrile butadiene styrene (ABS) Colour similar to RAL 7035 Cable entry 2 x M20 Weight AC 330 g DC 230 g Dimensions Mounting holes 120 80 55 55 Ø 4.1 operating voltage evaluation circuit connector M20 fi bre optic cable 1 m 108 Ordering details suitable for... Rated voltage Article number any flashing light with a 1 Hz flash rate 24 V DC 291 30 80 0 000 Article numbers for other voltages on request 104 www.pfannenberg.com

Mechanical data Material PROTECTIVE CAGES For protection against large mechanical demands. A very useful accessory for visual signaling devices fi tted to vehicles, such as fork lift trucks or driverless transport vehicles. Protective cages steel, powder-coated Colour white, similar to RAL 9016 Accessories + Light sources Dimensions for PD for WBL/WBS, DWBL/DWBS 136 100 144 85 89 70 for ABL/ABL, WB-M for WBLR/WBSR 85 Ø 6.2 198 3 155 3 Ø 4.3 96 3 70 80 Ordering details suitable for... Weight Article number PD 165 g 287 10 50 0 040 WBL/WBS, DWBL/DWBS 55 g 287 10 50 0 041 ABL/ABS, WBL-M/WBS-M 65 g 287 10 50 0 042 WBLR/WBSR 52 g 287 10 50 0 043 ACCESSORIES PYRA FLASHING LIGHTS Ordering details Article numbers PY X-S PY X-M Enclosure fitting Surface gasket Tamper-proof sealing (pack of 4) Panel mount installation kit PYRA For connection (daisy-chaining) of several fl ashing lights of the PY X-S series. Sealing of the fl ashing light installation surface when, e.g. cable entry is executed from the back. Anti-tamper sealing for fasteners of the PYRA devices after installation in order to prevent manipulation of the devices. The PYRA devices are also suitable for panel mounting. This kit consists of a plug connector for the electrical contact, as well as all installation materials. 283 00 00 0 003 283 00 00 0 004 281 11 50 0 000 283 00 00 0 002 283 00 00 0 010 Further technical information can be found on our website at www.pfannenberg.com 105

VISUAL SIGNALING DEVICES TUBULAR STAND Tubular stand for mounting SPECTRA lights. Dimensions P 200 TMA001 P 300 TMA001 P 400 TMA001 4 pieces included 4 pieces included 4 pieces included 2 pieces included 54 60 90 2 pieces included 54 60 90 54 3 pieces included 60 90 seal enclosed Ordering details Article numbers Height P 200 TMA001 P 300 TMA001 P 400 TMA001 for P 200 series 137 mm 213 91 00 0 000 for P 300 series 140 mm 213 93 00 0 000 for P 400 series 145 mm 213 95 00 0 000 further tubular stand lengths on enquiry WALL HOLDER WITH HOOD Wall holder for mounting SPECTRA lights on tubular stands. Dimensions BR 50-W 110 84.6 73 59.3 42.5 40 65 60 Ø 4.5 75 50 27 62.4 61.3 23 16 13.7 12.6 Ø 55 9.5 61.4 86.7 4 x Ø 4.6 Ordering details suitable for... Article number mounting the P 200 / P 300 / P 400 series on tubular stands 282 50 20 0 000 106 www.pfannenberg.com

WALL BRACKET Wall bracket for mounting SPECTRA lights. Accessories + Light sources Dimensions P 200 RAB001 P 300 RAB001 P 400 RAB001 2 pieces included 2 pieces included 3 pieces included seal enclosed 58 92 130 27 96 2 pieces included 3 pieces included 4 pieces included 27 Ordering details Article numbers P 200 RAB001 P 300 RAB001 P 400 RAB001 for P 200 series 213 90 00 0 000 for P 300 series 213 92 00 0 000 for P 400 series 213 94 00 0 000 WALL BRACKET FOR TRAFFIC LIGHTS Metal wall bracket for traffi c lights and combinations. Ordering details Article numbers P 350 TMB P 450 TMB Wall bracket for single mounting of the P 350 213 98 00 0 000 Wall bracket for single mounting of the P 450 213 99 00 0 000 Wall bracket set for combinations of 2 or 3 P 350 213 96 00 0 000 Wall bracket set for combinations of 2 or 3 P 450 213 97 00 0 000 Further technical information can be found on our website at www.pfannenberg.com 107

VISUAL SIGNALING DEVICES SOFT START MODULE SSM2 The module enables the soft start and limitation of the large initial current peaks of capacitive consumers. This includes all DC devices with a smoothing capacitor on the voltage input, regardless of whether the devices are sounders or fl ashing lights. The SSM soft start module prevents the overloading of the relay contacts when switching on and the premature triggering of overcurrent circuit breakers (e.g. PLC controller). The module is available as a built-in housing for DIN rail mounting or is already integrated in various devices. Data SSM2 Rated voltage 24 V DC Operating range 18 30 V Nominal current consumption 1 A Operating temperature - 40 C... + 50 C Storage temperature - 40 C... + 70 C Relative humidity 90% Ordering details suitable for... Article number DC devices 410 00 00 0 500 Amps î up to 12 A without SSM with SSM 0 1 2 3 4 5 6 7 8 9 10 11 12 ms Current limitation 0.7 1.5 A 0 1 2 3 4 5 6 7 8 9 10 11 12 LIGHT SOURCES FILAMENT LAMPS Filament lamps for Pfannenberg lights with socket Product suitable for... Rated voltage Article number Filament lamp E14 15 W PD / P 350 TSB / P 450 TDB 24 V 281 13 00 0 000 Filament lamp E14 15 W PD / P 350 TSB / P 450 TDB 12 V 281 13 00 0 001 Filament lamp E14 15 W PD / P 350 TSB / P 450 TDB 48 V 281 13 00 0 002 Filament lamp E14 15 W PD / P 350 TSB / P 450 TDB 110 V 281 13 00 0 003 Filament lamp E14 15 W PD / P 350 TSB / P 450 TDB 240 V 281 13 00 0 004 Filament lamp E27 25 W P 450 TSB 24 V 281 13 00 0 019 Filament lamp E27 25 W P 450 TSB 115 V 281 13 00 0 020 Filament lamp E27 25 W P 450 TSB 230 V 281 13 00 0 021 Halogen lamp G6.35/GY6.35 20 W P 300 RTH 12 V 281 13 00 0 027 Halogen lamp G6.35/GY6.35 20 W P 300 RTH 24 V 281 13 00 0 028 Halogen lamp G6.35/GY6.35 25 W P 300 RTH 115 V 281 13 00 0 029 Halogen lamp G6.35/GY6.35 25 W P 300 RTH 230 V 281 13 00 0 030 Halogen lamp G6.35/GY6.35 35 W P 400 RTH 12 V 281 13 00 0 031 Halogen lamp G6.35/GY6.35 35 W P 400 RTH 24 V 281 13 00 0 032 Halogen lamp G6.35/GY6.35 40 W P 400 RTH 115 V 281 13 00 0 033 Halogen lamp G6.35/GY6.35 40 W P 400 RTH 230 V 281 13 00 0 034 108 www.pfannenberg.com

CONNECTION DIAGRAMS PMF 2030 PMF 2020 PMF 2015 operating mode switch AC DC connecting terminal strain relief operating mode switch (sliding switch) quad fl ash Connection diagrams 1/L 2/N X1 S1 double fl ash connecting terminal U b 230 V AC The operating modes quad fl ash (factory setting), double fl ash and single fl ash can be set via the DIP switch, which is accessible from the side. The operating modes quad fl ash (factory setting) and double fl ash can be set via the DIP switch, which is accessible from the side. ABL ABS / WBS / DWBS WBS-M WBL / WBL-PX DWBL WBL-M 230 V AC Quadro S / Quadro S-M-Flex bridge (for master fl ashing lights only) S1 (option -M-Flex) X1 for supplying additional fl ashing lights S1 X1 X1 (option -M-Flex) X2 X2 alarm output X2 Quadro F12 PY X-M-10 / PY X-M-05 AC N L - + DC for supplying additional fl ashing lights N L + - for supplying additional fl ashing lights operating voltage connection Further technical information can be found on our website at www.pfannenberg.com 109

VISUAL SIGNALING DEVICES WBSR WBLR (< 42 V AC) WBLR (> 110 V AC) L N P 300 STR / P 400 STR P 100 LDA P 200 LDA + L~ N ~ Colour D/C A/C brown + L~ blue N ~ PY X-S-05 resistor for line monitoring on operation voltage connection. (1 kohm) X1 X1 operating voltage connection P 400 LDA P 450 TLA / P 350 TLA + red L~ brown N ~ blue N ~ green stage 2 N ~ yellow stage 3 unit 3 L3/+3 unit 2 L2/+2 unit 1 L1/+1 N/ N/ Colour D/C A/C red / brown + L~ blue N ~ green stage 2 yellow stage 3 D/C A/C unit 3 +3 L3 unit 2 +2 L2 unit 1 +1 L1 general/neutral N general/neutral N AC DC 110 www.pfannenberg.com

PMF-LED Flex supply and operating mode control PD 2100-LED AC supply voltage operating mode control DC Connection diagrams 230 V AC 24 V AC/DC Quadro LED-TL P 300 LDA PD 2100-M-AS-i PD 2100-LED-M + red L~ brown N ~ blue N ~ green stage 2 operating voltage connection Colour D/C A/C red / brown + L~ blue N ~ green stage 2 programming socket alarm output PMF 2015-M optical receiver fl ash tube alarm output S1 (NC) 24V DC operating voltage fl ashing light fl ashing light controller monitoring circuit / failure signaling alarm relay with positively driven contacts (normal mode S1 open, S2 closed -> no failure) alarm output S2 (NO) 24V DC operating voltage fl ash monitoring 24 V DC operating voltage fl ashing light 24 V DC operating voltage fl ash monitoring external failure monitoring with short-circuit monitoring and wire breakage monitoring Further technical information can be found on our website at www.pfannenberg.com 111

OBSTACLE LIGHTS 112 www.pfannenberg.com

AVIATION SECURITY OBSTRUCTION LIGHTING SYSTEMS RELIABLE SOLUTIONS FOR ALL REQUIREMENTS OF OBSTRUCTION LIGHTS Obstacle Lights Pfannenberg, the inventor of the industrial flashing light, provides innovative solutions for the Safety for man, machine and the environment. With intelligent, communicative LED obstruction lights Pfannenberg offers a new technology to mark air traffic obstacles, safely and durably. Further technical information can be found on our website at www.pfannenberg.com 113

OBSTACLE LIGHTS THE NEW GENERATION: THE PFANNENBERG OBSTRUCTION LIGHT CONCEPT Plug & Play: After the connection to a power supply source, each obstruction light is immediately ready for use without any additional accessories. Long-life technology: For the fi rst time, obstruction lights accompany your wind power plants during their entire life cycle. Intelligent function management for the highest possible availability with a constant signal quality and under all ambient conditions. Communication: Flash synchronisation with built-in GPS receiver, twilight switch and as an option a wireless network for each system. COMPACTLY INTEGRATIVE Pfannenberg LED obstruction lights of the latest generation completely integrate the control and communication modules inside the compact beacon housing. One side effect coming along with this feature: Weight reduction of more than 25% in comparison to conventional lightning systems. In case of the replacement of older beacons, Pfannenberg obstruction lights can be connected to any existing UPS systems and due to various installation kits we are able to adapt the light to almost all mechanical interfaces. STRONG IN COMMUNICATION Continuous communication with the embedded sensors and the obstruction lights of all wind turbines integrated into the respective park concept, creates easily a homogeneous structure of system behaviour. This will be realized by the optional wireless network built into the beacon housing. All participating beacons of this so called Mesh-Network of one or more connected wind farm, communicate via this interface to synchronize twilight switchover and the control of the light intensity according to the visibility measurement. 114 www.pfannenberg.com

ALL OBSTACLE LIGHTS AT A GLANCE Type Approval Flash Sync. ICAO FAA AVV type type Twilight Switch Visibility Control Data Logger Onshore/ Offshore Wireless Network Page LOW INTENSITY POL 10-H A POL 32-H B L-810 POL 10-M A POL 10-M-R A POL 10-M-RA A POL 32-M B L-810 116 118 Obstacle Lights POL 170W-RED-ES 1 120 MEDIUM INTENSITY POL 2.000R-B B L-864 POL 2.000R-C C 120 POL 20.000/2.000R-C A, C POL 20.000/ 170W-RED-ES POL 20.000/ 2.000R-B A A, B L-864 / L-865 122 POL 20.000/2.000W A L-865 standard option 1 ES = Extended Specifi cation acccording to AVV POL SERIES STANDARD AND OPTIONAL BENEFITS Standard Integrated Twilight Switch, On/Off Switch Integrated GPS module for flash synchronisation Integrated Data Logger e.g. of visibility adjustment Integrated RS485 Communication Interface cable cable Integrated Lightning Protection Integrated Function Monitoring with dry-contacts for warning and alarm 24 V DC Optional Visibility Sensor Minimisation of light emission by light intensity adjustment Synchronisation via wireless network with other lights surrounding (e. g. on windparks) concerning twilight switching and light intensity adjustment according to the visibility Further technical information can be found on our website at www.pfannenberg.com 115

OBSTACLE LIGHTS LED OBSTACLE LIGHTS POL 10-H, POL 32-H LED obstacle lights, AVV-approved, compliant to ICAO Annex 14, Volume 1, Chapter 6. Especially designed for horizontal mounting/operation therefore highly suitable for night marking of aviation obstacles such as windturbines and chimneys easiest push-through mounting solution for quick and safe fi xation on concrete or steel towers horizontal radiation angle of 180 requires only 4 units per light level seawater resistant, anodized aluminium and UV resistant lens material integrated twilight switch for day/night switchover extremely long service life of over 100,000 hrs., hence maintenance-free equipped with mounting-friendly plug contact POL 10-H AVV Approval pending ICAO Approval pending Offshore Sea water resistance IP 68 Proctection system + 50 C - 40 C Operating temperature Electrical data POL 10-H POL 32-H Rated voltage 24 V DC Operating range 15 30 V DC 15 30 V DC Power consumption 2 W 3 W Mechanical data POL 10-H POL 32-H Operating mode continuous light Light source high output LEDs Light intensity (DIN 5037) > 10 cd > 32 cd Lens colour clear Light colour aviation red Beam angle vertical - 2... + 10 horizontal > 180 Operating temperature - 40 C... + 50 C Storage temperature - 40 C... + 70 C Relative humidity 100% Protection system according to EN 60529 IP 68 Duty cycle 100% Service life of light source > 100,000 hrs Material lens polymethyl methacrylate (PMMA), UV resistant housing sea water-resistant aluminium (anodised) Mounting horizontal, push-through mounting Dimensions Ø 50 mm, length on request Type of connection plug connection Weight 1 kg 1 kg Approvals ICAO / AVV (pending) ICAO / AVV (pending) ICAO type Low Intensity, type A Low Intensity, type B 116 www.pfannenberg.com

Dimensions Tower outside 36 max. Tower inside Ø 52 151.5 mounting: simulation tower with drilling Ø 52 mm Obstacle Lights Ordering details Article numbers POL 10-H POL 32-H Standard on request on request with wireless network on request on request Options / Accessories Connecting cable Article number: see page 126 Conformity to standards The lights complies with the requirements of ICAO, Annex 14, Volume 1, Chapter 6. The lights are approved in Germany in accordance with the General Administrative Rules for the Identifi cation of Aircraft Obstructions (AVV). Further technical information can be found on our website at www.pfannenberg.com 117

OBSTACLE LIGHTS LED OBSTACLE LIGHTS POL 10, POL 32 LED obstacle lights, AVV-approved, compliant to ICAO, Annex 14, Volume 1, Chapter 6 omnidirectional light with a radiation angle of 360 for operation at night and at twilight (night identification of aviation obstacles) 2 in 1: optional completely redundant construction of LED, electronics and power supply in one housing. A 2nd light is therefore not necessary. automatic switching over to standby light in case of error or by means of external control system integrated function monitoring with potential-free fault contact extremely long service life of over 50,000 hrs., hence maintenance-free optionally equipped with mounting-friendly plug contact POL 10 AVV ICAO IP 68 + 55 C - 40 C Approval Approval Proctection system Operating temperature Electrical data POL 32 POL 10 Rated voltage 115 / 230 V AC 48 V DC 12 / 24 V DC 115 / 230 V AC 48 V DC 12 / 24 V DC Rated frequency 50 / 60 Hz 50 / 60 Hz Operating range 85 265 V 40 57 V 9.6 28.8 V 85 265 V 40 57 V 9.6 28.8 V Current consumption, 115 V 96 ma 60 ma determined arithmetically 230 V 45 ma 40 ma 48 V 270 ma 180 ma 24 V 430 ma 350 ma 12 V 800 ma 600 ma Fault contact NC max. 230 V, 80 ma Mechanical data POL 32-M POL 10-M POL 10-M-R POL 10-M-RA Operating mode continuous light Light source LED array (red) 2 x LED array monitored (standard) Version redundant Activation of standby light in case of error by means of external switching automatic switching Light intensity (DIN 5037) > 32 cd > 10 cd Lens colour Light colour Beam angle clear aviation red vertical approx. ± 35 horizontal360 Operating temperature - 40 C... + 55 C Storage temperature - 40 C... + 70 C Relative humidity 100% Protection system according to EN 60529 IP 68 Duty cycle 100% Service life of light source Material Mounting > 50,000 hrs lens polycarbonate (PC) base polybutylene terephthalate (PBT) direct mounting Connecting terminals 0.5-1.5 mm 2 fi ne wire - H05(07)V-K, 0.5-2.5 mm 2 single wire - H05(07)V-U Weight approx. 750 g Approvals ICAO ICAO / AVV ICAO / AVV ICAO / AVV 118 www.pfannenberg.com

Dimensions 19 3.5 90 168.5 153 8.5 240 134 Ø 114 PG16 (4 x) Ø 118 27 Obstacle Lights POL 32-M POL 10 operating voltage 48 V DC fault contact main light 48 V DC fault contact standby light 48 V DC Ordering details Article numbers POL 32-M POL 10-M POL 10-M-R POL 10-M-RA Rated voltage 115 / 230 V AC 211 05 68 1 005 211 05 64 1 005 211 05 64 1 011 211 05 64 1 010 48 V DC 211 05 66 1 005 211 05 65 1 005 211 05 65 1 011 211 05 65 1 010 12 / 24 V DC 211 05 67 1 005 211 05 63 1 005 211 05 63 1 011 211 05 63 1 010 Options / Accessories Plug connector Conformity to standards The lights complies with the requirements of ICAO, Annex 14, Volume 1, Chapter 6. The lights are approved in Germany in accordance with the General Administrative Rules for the Identifi cation of Aircraft Obstructions (AVV). Further technical information can be found on our website at www.pfannenberg.com 119

OBSTACLE LIGHTS LED OBSTRUCTION LIGHTS POL 170W-R, POL 2.000R LED obstruction lights for the night identification of aviation obstructions such as wind energy turbines and high buildings/structures dimmable light intensity depending upon the visual range integrated degradation and function monitoring of the LEDs integrated lightning protection passive cooling; no wearing parts requiring maintenance extremely long useful life of more than 20 years (depending upon ambient temperature) extreme vibration resistance due to LED technology sea-water resistant housing material mechanically compatible to combi lights integrated fl ash synchronisation of several lights integrated twilight switch for switching between day/night operation integrated data logger for visibility adjustment AVV Approval 2.000R 2.000R-B ICAO Approval FAA Approval (Typ L-864) Offshore Sea water resistance IP 68 Proctection system + 50 C - 40 C Operating temperature Electrical data POL 170W-RED-ES POL 2.000R-B POL 2.000R-C Rated voltage 24 V DC (15 30 V DC) Power consumption @ 100% 15 W 11 W 35 W Mechanical data POL 170W-RED-ES POL 2.000R-B POL 2.000R-C Operating mode blinking light blinking light continuous light Light source 18 high output LEDs 24 high output LEDs 24 high output LEDs Blinking frequency 1 s ON - 0.5 s OFF - 1 s ON - 1.5 s OFF 20/min. or 40/min. steady Light intensity (DIN 5037) 170 cd according to AVV 2,000 cd according to ICAO 2,000 cd according to ICAO Intensity control Lens colour Light colour 30% / 10% (only in connection with a visibility measuring device) clear aviation red Operating temperature - 40 C... + 50 C Storage temperature - 55 C... + 55 C Relative humidity 100% Protection system according to EN 60529 IP 68 Duty cycle 100% Service life of light source > 100,000 hrs @ 25 C Material Type of connection lens housing polymethyl methacrylate (PMMA), UV resistant sea water-resistant aluminium (anodised) and sea water-resistant stainless steel plug connection, Hummel M23 Weight 8 kg 15 kg 15 kg Approvals AVV ICAO / AVV / FAA ICAO / AVV / FAA ICAO type Medium Intensity, type B Medium Intensity, type C 1 ES = Extended Specifi cation acccording to AVV 120 www.pfannenberg.com

Dimensions POL 170W-RED-ES POL 2.000 R-B POL 2.000R-C Ø 258 20 60 100 Ø 258 120 Ø 352 130 33 183 brightness sensor 19.5 serial no. mounting thread Obstacle Lights sign FAA (option) electric connector breathing vent Ordering details Article numbers POL 170W-RED-ES POL 2.000R-B POL 2.000R-C Standard 214 61 63 1 010 214 64 63 1 004 214 64 63 1 006 with wireless network 214 61 63 1 013 214 64 63 1 005 214 64 63 1 007 Options / Accessories Visibility sensor Article number: see page 126 Assembly kit Article number: see page 126 Connecting cable Article number: see page 126 Conformity to standards The lights complies with the requirements of ICAO, Annex 14, Volume 1, Chapter 6. The lights are approved in Germany in accordance with the General Administrative Rules for the Identifi cation of Aircraft Obstructions (AVV). Further technical information can be found on our website at www.pfannenberg.com 121

OBSTACLE LIGHTS LED (COMBI) OBSTRUCTION LIGHTS POL 20.000/2.000R, POL 20.000/170W-R, POL 20.000/2.000W LED hazard beacons for the night identification of aviation obstructions such as wind energy turbines and high buildings/structures dimmable light intensity depending upon the visual range integrated degradation and function monitoring of the LEDs integrated lightning protection passive cooling; no wearing parts requiring maintenance extremely long useful life of more than 20 years (depending upon ambient temperature) extreme vibration resistance due to LED technology sea-water resistant housing material integrated fl ash synchronisation of several lights integrated twilight switch for switching between day/night operation integrated data logger for visibility adjustment AVV Approval ICAO Approval FAA Approval pending Offshore Sea water resistance Combi light (Day/Night) IP 68 Proctection system + 50 C - 40 C Operating temperature Electrical data POL 20.000/2.000R-C POL 20.000/170W-RED-ES POL 20.000/2.000R-B POL 20.000/2.000W Rated voltage 24 V DC (15 30 V DC) Power consumption @ 100% 77 W / 35 W 77 W / 6 W 77 W / 11 W 77 W / 11 W Mechanical data POL 20.000/2.000R-C POL 20.000/170W-RED-ES POL 20.000/2.000R-B POL 20.000/2.000W Operating mode Light source Blinking frequency blinking or continuous light 24 LEDs (white) & 24 LEDs (red) 20/min. or 40/min. / steady 24 LEDs (white) & 144 LEDs (red) 20/min. or 40/min. / 1 s ON - 0.5 s OFF - 1 s ON - 1.5 s OFF blinking light 24 LEDs (white) & 24 LEDs (red) 20/min. or 40/min. / 20/min. or 40/min. 24 LEDs (white) 20/min. or 40/min. / 20/min. or 40/min. Light intensity day identifi cation 20,000 according to ICAO (DIN 5037) night identifi cation 2,000 cd according to ICAO 170 cd according to AVV 2,000 cd according to ICAO 2,000 cd Intensity control 30% / 10% (only in connection with a visibility measuring device) Lens colour clear Light colour day identifi cation white white white white night identifi cation red red red white Operating temperature - 40 C... + 50 C Storage temperature - 55 C... + 55 C Relative humidity 100% Protection system according to EN 60529 IP 68 Duty cycle 100% Service life of light source > 100,000 hrs @ 25 C Material lens polymethyl methacrylate (PMMA), UV resistant housing sea water-resistant aluminium (anodised) and sea water-resistant stainless steel Type of connection plug connection, Hummel M23 Weight 15 kg Approvals ICAO / AVV AVV ICAO / AVV / FAA ICAO / FAA ICAO type Medium Intensity, type A&C Medium Intensity, type A Medium Intensity, type A&B Medium Intensity, type A&A 122 www.pfannenberg.com

Dimensions Ø 352 130 33 183 Obstacle Lights Ordering details Article numbers POL 20.000/2.000R-C POL 20.000/170W-RED-ES POL 20.000/2.000R-B POL 20.000/2.000W Standard 214 60 63 1 006 214 60 63 1 011 214 60 63 1 004 214 60 63 1 008 with wireless network 214 60 63 1 007 214 60 63 1 012 214 60 63 1 005 214 60 63 1 009 Options / Accessories Visibility sensor Article number: see page 126 Assembly kit Article number: see page 126 Connecting cable Article number: see page 126 Conformity to standards The lights complies with the requirements of ICAO, Annex 14, Volume 1, Chapter 6. The lights are approved in Germany in accordance with the General Administrative Rules for the Identifi cation of Aircraft Obstructions (AVV). Further technical information can be found on our website at www.pfannenberg.com 123

OBSTACLE LIGHTS Basic circuit of obstruction light system Communication Signal Relay RS485-1 RS485-2 RS485-1 24 V 24 V RS485-2 Visibility Sensor Power Supply optional 2nd obstruction light and/or visibility sensor Electrical connection - Basic configuration Obstruction Light 1 (Master) Obstruction Light 2 (Slave) Visibility Sensor Vaisala PWD20 Pin Designation Pin Designation Pin Designation Power Supply 1 GND 1 GND 2 GND 11 GND 11 GND 12 GND 12 GND 2 24 V U+ 2 24 V U+ 1 24 V U+ 3 24 V U+ 3 24 V U+ 13 24 V U+ 13 24 V U+ 17 SVInfo 17 SVInfo Communication 10 RS485-1 D- 16 RS485-1 D+ 8 RS485-2 D- 10 RS485-1 D- 9 RS485-2 D+ 16 RS485-1 D+ 8 RS485-2 D- 3 RS485 D- 9 RS485-2 D+ 4 RD485 D+ Signal Relay 4 K1 / Common 14 K1 / Warning 5 K1 / Warning 6 K2 / Common 7 K2 / Fail 15 K2 / Fail 4 K1 / Common 14 K1 / Warning 5 K1 / Warning 6 K2 / Common 7 K2 / Fail 15 K2 / Fail Electrical connection - PIN assignment and function Signal Connector pin Function 24 V U+ 2, 3, 13 supply voltage GND 1, 11, 12 ground RS485 Port 1 Data + RS485 Port 1 Data - RS485 Port 2 Data + RS485 Port 2 Data - 16 10 9 8 PC terminal interface or slave communication port Interface to the visibility sensor or master communication port SV Info 17 test mode and voltage supply identifi cation GND: inactive / +24 V: test mode frequency: identifi cation of the power supply K1 Common 4 relay 1 reference point K1 / Warning 14 relay 1 contact open when warning or night modus is active (light is blinking) K1 / Warning 5 relay 1 contact closed when warning or night modus is active (light is blinking) K2 / Common 6 relay 2 reference point K2 / Fail 7 relay 2 contact open when errors are present K2 / Fail 15 relay 2 contact closed when errors are present 124 www.pfannenberg.com

ACCESSORIES POWER SUPPLY / BATTERY BACKUP complete solution for uninterrupted power supply of obstruction lights plug&play solutions with integrated connectors available several back-up times for all applications and countries always integrated in a switch cabinet Technical data Night Night-MINI Day/Night Power Supply / Battery Backup Day/Night - Plug Day/Night- Plug-MAXI Night-Tower Plug INPUT Rated voltage 100-240 V AC 100-240 V AC 200-240 V AC 200-240 V AC 200-240 V AC 100-240 V AC Rated frequency 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz Rated current 1.4 A @ 230 V 1.4 A @ 230 V 4.6 A @ 230 V 4.6 A @ 230 V 4.6 A @ 230 V 1.4 A @ 230 V Inrush current 45 A 45 A 14 A 14 A 14 A 45 A OUTPUT Voltage 24 V DC 24 V DC 24 V DC 24 V DC 24 V DC 24 V DC Max. current 22 A 10 A 2 x 22 A 40 A 40 A 4 x 350 ma Capacity of the batteries 51 Ah 3.5 Ah 51 Ah 51 Ah 92 Ah 3.5 Ah Operating temperature - 15 C... + 50 C - 10 C... + 50 C - 15 C... + 50 C - 15 C... + 50 C - 15 C... + 50 C - 10 C... + 50 C Storage temperature - 20 C... + 65 C - 20 C... + 65 C - 20 C... + 65 C - 20 C... + 65 C - 20 C... + 65 C - 20 C... + 65 C Dimensions (HxWxD) 540 x 500 x 225 mm 340 x 380 x 210 mm 540 x 500 x 225 mm 540 x 500 x 225 mm 540 x 500 x 225 mm 340 x 380 x 210 mm Weight 50 kg 17 kg 50 kg 50 kg 90 kg 50 kg Cable connection open end cable connector open end cable connector connector connector Back-up time (number of lights x time [h]) @ + 25 C POL 170W-RED-ES 2 x 40 h 2 x 2 h 2 x 40 h 2 x 35 h - - POL 2000R-B 2 x 50 h 2 x 2.5 h 2 x 50 h 2 x 45 h - - POL 2000R-C - - 2 x 17 h 2 x 14 h 2 x 25 h - POL 20.000/2.000W-A - - 2 x 8.5 h 2 x 7 h 2 x 13 h - POL 20.000/170W-RED-ES - - 2 x 8.5 h 2 x 7 h 2 x 13 h - POL 20.000/2.000R-B - - 2 x 8.5 h 2 x 7 h 2 x 13 h - POL 20.000/2.000R-C - - 2 x 8.5 h 2 x 7 h 2 x 13 h - POL 10 - - - - - 4 x 2.5 h POL 10-H - - - - - 4 x 2.5 h POL 32 - - - - - 4 x 2 h POL 32-H - - - - - 4 x 2 h Obstacle Lights Ordering details Article numbers Day/Night - Night Night-MINI Day/Night Plug Day/Night- Plug-MAXI Night-Tower Plug 280 11 00 0 002 280 13 00 0 006 280 11 00 0 003 on request 280 11 00 0 004 280 13 00 0 007 Further technical information can be found on our website at www.pfannenberg.com 125

OBSTACLE LIGHTS ACCESSORIES VISIBILITY SENSOR The visibility sensor identifi es different precipitation types, such as rain, drizzle, leet, snow and other weather-related constraint factors such as fog, mist or haze caused by smoke and sand. It allows a reliable determination of visibility over a range from 10 to 20,000 meters and is designed for both onshore and offshore use. Technical data Visibility Sensor Rated voltage electronics 12... 50 V DC hood heating 24 V AC/DC Power consumption incl. window heater 3 W @ 12 V DC incl. hood heating 65 W Functional principle optical forward scattering Relay contacts 3 pieces, programmable visibility alarm thresholds and delays can be confi gured, error message Serial ports RS-232, RS 485 Analog exit 0... 1 ma, 4... 20 ma Operating temperature - 40 C... + 60 C Relative humidity 0... 100% Protection system IP 66 Dimensions (HxWxD) 199 x 695 x 404 mm Weight 3 kg ASSEMBLY KITS The range of accessories for Pfannenberg obstruction lights includes several assembly kits, where the extent and compilation of components vary depending on the respective installation tasks. In general, the Pfannenberg package for the provision of obstructions lights and their installation also includes the corresponding sets. Ordering details Accessories Article numbers Circular mounting base, aluminium (seawater-resistant) Waisted mounting base, aluminium (seawater-resistant) Square mounting base, aluminium (seawater-resistant) Mounting pillar, aluminium (seawater-resistant) Outrigger, aluminium, as support for lightning arrester Fixing screw set stainless steel (A4) natural Stainless steel cable ties, natural, for outdoor use, minimum retention force 670 N Cable ties, plastic for indoor installation on request Sturdy UV and weather-resistant cable, of various lengths, finished on the lamp side with a Hummel M23 stainless steel connector. The side opposite the cable can be customized freely Cable glands, filler plugs and sealing plugs Cable lugs / cable end ferrules for replacement sets Fuses for replacement sets Service terminals Lighting arrester for installation at the outrigger Visibility Sensor PWD 20W 280 13 00 0 001 Thermo-Reflector 280 13 00 0 004 126 www.pfannenberg.com

Mounting options Square mounting base Waisted mounting base Circular mounting base 150 134 80 Ø 135 Ø 10 2 x M8 90 Ø 48 30 70 64 4 x R10 117 R25 60 75 Ø 48 + 0.1 0 12 x Ø 9 R25 150 155 200 240 135 Ø 48 0-0.1 Ø 155 2 x M10 Obstacle Lights 55 35 20 40 30 10 Ø 90 R25 M 8 15 Ø 8.5 100 M8 M8 Ø 48 + 0 0.1 M10 76 Lighting arrester Ø 8.5 Mounting pillar M10 150 125 Circular mounting base Outrigger Waisted mounting base Square mounting base Further technical information can be found on our website at www.pfannenberg.com 127

AUDIBLE SIGNALING DEVICES 128 www.pfannenberg.com

SOUND WAVES ARE A LANGUAGE THAT EVERYBODY UNDERSTANDS! USE OUR RANGE OF AUDIBLE SIGNALING DEVICES FOR ALL INDUSTRIAL AREAS OF APPLICATION Audible signaling ng devices A baby s cry, cars sounding their horns, the front door bell acoustic signals are part of our life right from the very beginning. All over the world. Everybody who hears a loud acoustic signal feels called upon to act in some way, regardless of the situation. On the basis of these conditions, the use of acoustic signaling devices is also of great advantage in the industrial sector. Malfunctions are reported immediately, dangerous situations are displayed without delay. Benefi t from our wide range of acoustic signaling devices, which are guaranteed to draw the necessary attention in your company - when it really matters. Further technical information can be found on our website at www.pfannenberg.com 129

AUDIBLE SIGNALING DEVICES ALL AUDIBLE SIGNALING DEVICES AT A GLANCE Type Maximum covering distance for a 65 db ambient noise level in in metres (m) 1 Sound pressure level Protection system Dimensions (HxWxD) mm Approvals / Standards GL EN GOST UL 54-3 10 100 250 500 1500 MED VdS RS Page SOUNDERS DS 5 105 db (A) IP 66 IP 67 133.5 x 133.5 x 143 132 DS 10 110 db (A) DS 5-DN 105 db (A) IP 66 IP 67 133.5 x 133.5 x 143 134 2 PA 1 100 db (A) IP 66 IK 08 86 x 109.5 x 80.6 2 136 2 PA 5 105 db (A) IP 66 IK 08 135 x 163.4 x 132 2 136 2 PA 10 110 db (A) IP 66 IK 08 170 x 214 x 156 2 138 2 PA 20 120 db (A) IP 66 IK 08 170 x 214 x 181 2 138 PA 130 130 db (A) IP 54 285 x 490 x 595 142 SAFETY-RELATED SOUNDERS DS 5-SIL 105 db (A) IP 66 IP 67 133.5 x 133.5 x 143 144 DS 10-SIL 110 db (A) available in preparation 2 option 130 www.pfannenberg.com

Type Maximum covering distance for a 65 db ambient noise level in in metres (m) 1 ELECTRONIC BUZZERS Sound pressure level Protection system Dimensions (HxWxD) mm Approvals / Standards GL EN GOST UL 54-3 10 100 250 500 1500 MED VdS RS Page P 22 DBZ 80 db (A) @ 10 cm IP 40 Ø 29 x 62 146 P 28 DMC948 91 db (A) P 28 DMC201 P 28 DMC301 P 28 DMB530 91 db (A) 91 db (A) 91 db (A) 1 The specifi cation for the alarm signal reception range assumes an existing ambient noise level of 65 db (A). In accordance with applicable regulations, the calculated alarm range for the sound level 65 db (A) was given + 10 db (A) = 75 db (A). IP 65 Ø 35.8 x 38.2 146 available in preparation Audible signaling devices Note: Using sounders with a sound pressure level of 120 db (A) can lead to hearing damage. People must not be permitted to stay in the near vicinity of the sounder. All specifi ed sound pressure levels are based on a measurement distance of 1 m, provided that nothing different is specifi ed. Further information can be found on the Internet: www.pfannenberg.com www.pfannenberg-spareparts.com Keep up to date. Subscribe to our newsletter now: newsletter.pfannenberg.com Further technical information can be found on our website at www.pfannenberg.com 131

AUDIBLE SIGNALING DEVICES SOUNDERS 105/110 db(a) DS 5 / DS 10 The sounders from the DS 10 / DS 5 series can be used for tough demands under industrial conditions and as universal alarms. The sounders, which are suitable for use both indoors and outdoors, generate warning signals in 31 different tones can be selected with the aid of an internal switch. Optionally, a maximum of 3 additional tones can be switched to by means of an external controller. In addition to the factory settings, the tone combination can be individually selected by means of on-site programming (tone 32). Custom versions are available for special applications. The GL version is especially resistant to shock and vibration. volume control (DS 5) DS 5 DS 10 r = 32 m r = 56 m IP 66 IP 67 + 55 C - 40 C EN 54-3 VdS G28609 10 Years max. covering distance Protection system Operating temperature Acoustic penetration Warranty Electrical data DS 5 Rated voltage230 V AC 115 V AC 24 V AC 12 V DC 24 V DC 48 V DC Rated frequency 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz Operating range 195 253 V 95 127 V 19 29 V 10 15 V 19 29 V 41 53 V Nominal current consumption0.03 A 0.06 A 0.28 A0.28 A 0.28 A 0.28 A Electrical data DS 10 Rated voltage230 V AC 115 V AC 24 V AC 12 V DC 24 V DC 48 V DC Rated frequency 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz Operating range 195 253 V 95 127 V 19 29 V 10 15 V 19 29 V 41 53 V Nominal current consumption0.06 A 0.12 A 0.42 A0.3 A 0.42 A 0.42 A Mechanical data DS 5 DS 10 Sound pressure level 105 db (A) 110 db (A) Sound level reduction by - 20 db via potentiometer (optional) Alarm tones 32 / 2-stage alarm Operating temperature - 40 C... + 55 C Storage temperature - 40 C... + 70 C Relative humidity 90% Protection system according to EN 60529 IP 66, IP 67 Duty cycle 100% Material die-cast aluminium GD-AI Si12 Cu Surface coating epoxy resin paint RAL 3000, fl ame red Cable bushing 2 x M20 (1 x chrome-plated brass cable fi tting, 1 x chrome-plated brass blanking plug) Clamping range of the cable fitting 8 12 mm Connecting terminals max. 2.5 mm 2 Weight AC 2.15 kg DC 1.95 kg Options / Accessories External tone selection (2 variants) for controlling several tones over great distances: 1: for all voltages = potential-free NO function 2. for 12 V / 24 V = voltage input GOST GL 30457-83-HH C US 132 www.pfannenberg.com

Dimensions Ø 7 143 M20 x 1.5 133.5 150 blanking plug M20 71.5 71.5 Tone table Tone Description - Basic tone (preset: tone no. 1) Stage 2 3 4 0 no tone 1 5 4 1 1 Sawtooth, DIN tone 33404-3 Germany (emergency signal), PFEER PTAP 2 Interrupted tone, ISO 8201 (emergency evacuation signal) 3 2 4 1 4 3 3 Alternating tone 1 2 4 4 Continuous tone, UK BS5839-1 950 Hz 1 3 5 5 Interrupted tone 1 4 3 6 Sweeping 1 4 9 7 8 Alternating tone, France NFS 32-001 (fi re alarm) Interrupted tone, Sweden SS031711 (emergency signal) 3 10 4 2 3 4 9 Interrupted tone (fast), horn 1 3 4 10 Continuous tone 500 Hz 27 9 26 11 Continuous tone 725 Hz 1 17 9 12 Continuous tone 825 Hz EN54-3 27 9 26 13 Continuous tone 1200 Hz 1 5 3 14 Continuous tone 1500 Hz 1 4 10 15 Interrupted tone 1 24 12 16 Interrupted tone 1 24 15 17 Interrupted tone 1 11 9 1 factory setting 1200 Hz 500 Hz 950 Hz 1025 Hz 825 Hz 950 Hz 825 Hz 725 Hz 1 s EN54-3 1 s 1 s 1200 Hz 3 s 500 Hz 3 s 554 Hz 440 Hz 0.4 s 700 Hz 800 Hz 500 Hz 0.5 s 0.5 s 0.1 s 1.5 s 0.25 s 0.25 s 0.125 s 0.125 s 4 ms 4 ms 0.5 s 0.5 s 0.5 s 0.5 s 0.7 s 0.3 s EN54-3 Tone Description - Basic tone (preset: tone no. 1) Stage 2 3 4 18 Interrupted tone 19 7 4 19 20 21 22 Alternating tone, UK BS5839-1 (fi re alarm, railway crossing) Interrupted tone, IMO SOLAS III/50 + SOLAS III/6.4 (general alarm) Interrupted tone, IMO (leave ship) Slow whoop, evacuation alarm Netherlands NEN 2575 27 13 23 9 21 26 20 9 26 19 14 2 23 Siren 27 12 2 24 Alternating tone 1 16 12 25 Alternating tone 1 14 5 26 Alternating tone 4 9 27 27 Siren 13 23 19 28 Sweeping 7 10 4 29 30 Pulsating tone, industrial alarm Germany Interrupted tone, industrial alarm (Germany) 800 Hz 2.5 s 825 Hz 950 Hz 1 30 9 1 4 26 31 Sweeping, France NFC48-265 3 14 4 1200 Hz 500 Hz 32 selection of available tone combinations in stages 2, 3 and 4 2.5 s 0.25 s 1000 Hz 0.25 s 800 Hz 1 s 3.5 s 3 s 7 s 1 s 1 s 0.5 s 1 s 0.25 s EN54-3 EN54-3 2400 Hz 3 s const. 500 Hz 1075 Hz 0.5 s 825 Hz 0.5 s 900 Hz 0.25 s 500 Hz 1400 Hz 0.25 s 20 ms 1200 Hz 20 ms 1200 Hz 3 s const. 300 Hz 1500 Hz 1.5 s 700 Hz 1.5 s 1000 Hz 10 s 40 s 150 Hz 680 Hz 0.875 s 0.875 s 1600 Hz 1 s 1400 Hz 0.5 s 10 s Sounders Ordering details Article numbers DS 5 DS 10 Version Rated voltage 230 V AC 115 V AC 24 V DC 230 V AC 115 V AC 24 V DC Standard 231 06 10 0 000 231 06 15 0 000 231 06 80 0 000 231 11 10 0 000 231 11 15 0 000 231 11 80 0 000 GL 231 06 10 0 001 231 06 15 0 001 231 06 80 0 001 231 11 10 0 001 231 11 15 0 001 231 11 80 0 001 LSR (volume control) 231 06 10 0 151 231 06 15 0 151 231 06 80 0 151 TAS (external tone selection via closed function of the control voltage) 231 06 10 0 152 231 06 15 0 152 231 06 80 0 152 231 11 10 0 152 231 11 15 0 152 231 11 80 0 152 Article numbers for other voltages and versions on request Conformity to standards DIN EN 54-3: 2001 + DIN EN 54-3/A1: 2001 EN 50 130-4: 1996 EN 61 000-6-2 EN 61 000-6-3 EN 60 947-1: 2003 EN 60 529: 2000 Fire alarm systems - part 3: fire alarm devices; Audible signaling devices and annex A1 Stability of system components for fi re and burglar alarm systems EMV, stability for industrial areas EMV, emission standard for residential commercial, and light-industrial environments Low voltage switchgear standard Protection system by enclosure (IP code) DIN EN ISO 7731 Ergonomic alarms for public areas and workplaces acoustic alarms DIN 33 404/3: 1982 Alarms for workplaces, unifi ed emergency signal ISO 8201: 1987 Evacuation alarm DIN EN 981: 1997 System of acoustic and visual alarm signals and information signals ISO 11 429: 1996 System of acoustic and visual alarm signals and information signals Further technical information can be found on our website at www.pfannenberg.com 133

AUDIBLE SIGNALING DEVICES SOUNDER 105 db(a) DS 5-DN sounder with 2 externally controllable volume levels wherever sounders need to be operated virtually 24 hours a day for alarm purposes, e.g. in port areas, container terminals, conveyor belts in coal mines or for supplying power stations, it is important to disturb local residents as little as possible. This is especially the case in the evening and at night, when the ambient noise level is also lower. can also be used to avoid startled reactions by starting the alarm with a reduced sound level and increasing it in steps (soft alarm) the sound level can be reduced by an external controller or via a floating contact the reduction may be preselected during the installation in accordance with local conditions (0 to - 20 db) r = 32 m IP 66 IP 67 + 55 C - 40 C 10 Years max. covering distance Protection system Operating temperature Acoustic penetration Warranty Electrical data DS 5-DN Rated voltage230 V AC 115 V AC 24 V AC 12 V DC 24 V DC 48 V DC Rated frequency 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz Operating range 195 253 V 95 127 V 19 29 V 10 15 V 19 29 V 41 53 V Nominal current consumption0.03 A 0.06 A 0.28 A0.28 A 0.28 A 0.28 A Mechanical data DS 5-DN Sound pressure level 105 db (A) Sound level reduction externally adjustable up to - 20 db via potentiometer Alarm tones 32 / 2-stage alarm (see tone table page 133) Operating temperature - 40 C... + 55 C Storage temperature - 40 C... + 70 C Relative humidity 90% Protection system according to EN 60529 IP 66, IP 67 Duty cycle 100% Material die-cast aluminium GD-AI Si12 Cu Surface coating epoxy resin paint RAL 3000, fl ame red Cable bushing 2 x M20 (1 x chrome-plated brass cable fi tting, 1 x chrome-plated brass blanking plug) Clamping range of the cable fitting 8 12 mm Connecting terminals max. 2.5 mm 2 Weight AC DC 2.15 kg 1.95 kg Dimensions 143 Ø 7 M20 x 1.5 133.5 150 blanking plug M20 71.5 71.5 134 www.pfannenberg.com

Sounders Ordering details Article numbers DS 5-DN Version Rated voltage 230 V AC 115 V AC 24 V DC Standard 231 06 10 0 163 231 06 15 0 163 231 06 80 0 163 TAS (external tone selection via closed function of the control voltage) 231 06 10 0 162 231 06 15 0 162 231 06 80 0 162 Article numbers for other voltages and versions on request Options / Accessories External tone selection (2 variants) for controlling several tones over great distances: 1: for all voltages = potential-free NO function 2. for 12 V / 24 V = voltage input GOST Conformity to standards EN 61 000-6-2 EMV, stability for industrial areas EN 61 000-6-3 EMV, emission standard for residential commercial, and light-industrial environments EN 60 947-1: 2003 Low voltage switchgear standard EN 60 529: 2000 Protection system by enclosure (IP code) DIN EN ISO 7731 Ergonomic alarms for public areas and workplaces acoustic alarms DIN 33 404/3: 1982 ISO 8201: 1987 DIN EN 981: 1997 ISO 11 429: 1996 Alarms for workplaces, unifi ed emergency signal Evacuation alarm System of acoustic and visual alarm signals and information signals System of acoustic and visual alarm signals and information signals Further technical information can be found on our website at www.pfannenberg.com 135

AUDIBLE SIGNALING DEVICES PATROL SOUNDERS 100/105 db(a) PA 1 / PA 5 PATROL - the new generation of sounders. Three dimensional innovation; safe; an incorrect installation is virtually impossible easy; signifi cantly shorter assembly and installation times economical; extremely high efficiency and good penetration of acoustical obstacles significantly reduce the required number of sounders PA 1 PA 5 r = 18 m r = 32 m IP 66 IK 08 + 55 C - 40 C EN 54-3 VdS UL 10 Years max.covering distance Protection system Impact-proof housing Operating temperature Acoustic penetration 24 48 V DC 24 48 V DC Warranty Electrical data PA 1 Rated voltage230 V AC 115 V AC 24 V AC 10 57 V DC Rated frequency 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz Operating range 195 253 V 95 127 V 18 30 V 10 57 V Nominal current consumption 9 15 ma 8 30 ma 59 120 ma 6 80 ma Electrical data PA 5 Rated voltage230 V AC 115 V AC 24 V AC 10 57 V DC Rated frequency 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz Operating range ± 10% ± 10% ± 10% 10 57 V Nominal current consumption 1 9 15 ma 8 30 ma 59 120 ma 6 80 ma 1 power consumption dependent on operating voltage Mechanical data PA 1 PA 5 Sound pressure level 100 db (A) 105 db (A) Sound level reduction max. - 16 db via potentiometer Alarm tones 80 (see tone table page 140/141) Operating temperature - 40 C... + 55 C Storage temperature - 40 C... + 70 C Relative humidity 90% Protection system according to EN 60529 IP 66 Protection class II Duty cycle 100% Material PC / ABS blend Colour similar to RAL 3000 (fl ame red) / RAL 7035 (light grey) / RAL 9003 (signal white) Cable entry 3 x M20 knock-outs on side, 1 knock-out on back 5 x M20 knock-outs on side, 1 knock-out on back Integrated seal with cable entry 6 13 mm (feed-through grommet) Connecting terminals 2.5 mm 2 fi ne wire with cable end sleeve, AWG 16 Weight AC 405 g 778 g DC 270 g 643 g 136 www.pfannenberg.com

Dimensions PA 1 PA 5 163.4 37 135 Sounders 86 Ø 6.3 Ø 7.3 98 109.5 143 M20 knock-outs prepared 80.6 132 Ordering details Article numbers PA 1 PA 5 Version Rated voltage 230 V AC 115 V AC 10-57 V DC 230 V AC 115 V AC 10-57 V DC Standard housing red 233 10 10 0 000 233 10 15 0 000 233 10 63 0 000 233 50 10 0 000 233 50 15 0 000 233 50 63 0 000 GL housing red 233 10 10 0 001 233 10 15 0 001 233 10 63 0 001 233 50 10 0 001 233 50 15 0 001 233 50 63 0 001 Standard housing grey 233 10 10 0 055 233 10 15 0 055 233 10 63 0 055 233 50 10 0 055 233 50 15 0 055 233 50 63 0 055 GL housing grey 233 10 10 0 056 233 10 15 0 056 233 10 63 0 056 233 50 10 0 056 233 50 15 0 056 233 50 63 0 056 Article numbers for other voltages and versions on request Options / Accessories Enclosure fitting Surface gasket Tamperproof sealing Panel mounting kit I lim t See page 141 for further information GL MED CNBOP SSM (only for 24 V DC) Conformity to standards The acoustic parameters conform to the European standard DIN EN ISO 7731; Ergonomic alarm signals for public areas and workplaces acoustic alarm signals. The requirement for an acoustic alarm signal can be found in the harmonised standards: EN 60204-1 Electrical equipment of machines EN 60825-1 Radiation safety of laser devices, identical to IEC 825 and DIN-VDE 0837 Further technical information can be found on our website at www.pfannenberg.com 137

AUDIBLE SIGNALING DEVICES PATROL SOUNDERS 110/120 db(a) PA 10 / PA 20 PATROL - the new generation of sounders. Three dimensional innovation; safe; an incorrect installation is virtually impossible easy; signifi cantly shorter assembly and installation times economical; extremely high efficiency and good penetration of acoustical obstacles significantly reduce the required number of sounders PA 10 PA 20 r = 56 m r = 178 m IP 66 IK 08 + 55 C - 40 C EN 54-3 VdS UL 10 Years max. covering distance Protection system Impact-proof housing Operating temperature Acoustic penetration 24 48 V DC 115 230 V AC 24 48 V DC 115 230 V AC Warranty Electrical data PA 10 Rated voltage 95 265 V AC 24 V AC 10 60 V DC Rated frequency 50 / 60 Hz 50 / 60 Hz Operating range 95 265 V 20-30 V 10 60 V Nominal current consumption 20 115 ma 250 900 ma 60 485 ma Electrical data PA 20 Rated voltage 95 265 V AC 24 V AC 10 60 V DC Rated frequency 50 / 60 Hz 50 / 60 Hz Operating range 95 265 V 20-30 V 10 60 V Nominal current consumption 1 75 330 ma 500 1,800 ma 120 880 ma 1 power consumption dependent on operating voltage Mechanical data PA 10 PA 20 Sound pressure level 110 db (A) 120 db (A) Sound level reduction max. - 12 db via potentiometer Alarm tones 80 (see tone table page 140/141) Duty cycle 100% Operating temperature - 40 C... + 55 C Storage temperature - 40 C... + 70 C Relative humidity 90% Protection system according to EN 60529 IP 66 Protection class II Material PC / ABS blend Colour similar to RAL 3000 (fl ame red) / RAL 7035 (light grey) / RAL 9003 (signal white) Cable entry 5 x M20 knock-outs on side, 1 knock-out on back Integrated seal with cable entry 6 13 mm (feed-through grommet) Connecting terminals 2.5 mm 2 fi ne wire with cable end sleeve, AWG 16 Weight AC 1,060 g 1,200 g DC 1,050 g 1,090 g 138 www.pfannenberg.com

Dimensions PA 10 PA 20 156 214 190 181 Sounders 170 170 Ø 9 Ø 9 190 37 37 214 M20 knock-outs prepared 30 37 26 21 M20 knock-outs prepared Ordering details Article numbers PA 10 PA 20 Version Rated voltage 95-265 V AC 24 V AC 10-60 V DC 95-265 V AC 24 V AC 10-60 V DC Standard housing red 233 60 64 0 000 233 60 30 0 000 233 60 63 0 000 233 70 64 0 000 233 70 30 0 000 233 70 63 0 000 GL housing red 233 60 64 0 001 233 60 30 0 001 233 60 63 0 001 233 70 64 0 001 233 70 30 0 001 233 70 63 0 001 Standard housing grey 233 60 64 0 055 233 60 30 0 055 233 60 63 0 055 233 70 64 0 055 233 70 30 0 055 233 70 63 0 055 GL housing grey 233 60 64 0 056 233 60 30 0 056 233 60 63 0 056 233 70 64 0 056 233 70 30 0 056 233 70 63 0 056 Article numbers for other voltages and versions on request Options / Accessories Enclosure fitting Surface gasket Tamperproof sealing Panel mounting kit I lim t See page 141 for further information GL MED CNBOP SSM (only for 24 V DC) Conformity to standards The acoustic parameters conform to the European standard DIN EN ISO 7731; Ergonomic alarm signals for public areas and workplaces acoustic alarm signals. The requirement for an acoustic alarm signal can be found in the harmonised standards: EN 60204-1 Electrical equipment of machines EN 60825-1 Radiation safety of laser devices, identical to IEC 825 and DIN-VDE 0837 Further technical information can be found on our website at www.pfannenberg.com 139

AUDIBLE SIGNALING DEVICES Tone table PA 1 / PA 5 / PA 10 / PA 20 Basic tone no. Description Basic tone no. Description 1 no tone 2 9 Sawtooth, DIN tone 33404-3 Germany (emergency signal), PFEER PTAP Slow whoop, fi re alarm, UK BS5839-1 11 Interrupted tone (fast) 13 Interrupted tone 15 16 Slow whoop, evacuation alarm Netherlands NEN 2575 Slow whoop, Australian evacuation alarm AS2220 18 Slow whoop, NFPA 22 23 Siren 24 Siren 25 Siren 26 Pulsating tone, Australien alert AS1670, ISO8201 Pulsating tone, industrial alarm Germany 27Sweeping 29Sweeping (fast) 30Sweeping 31 Sweeping, France NFC48-265 33 Sweeping (medium), UK BS5839-1 34Sweeping (fast) 35 Sweeping (fast), UK BS5839-1 36Sweeping 43Sweeping 44 Sweeping, IMO 3d, Germany KTA3901 evacuation alarm 45Sweeping 46 Sweeping, general alarm Finland 52Continuous tone 53Continuous tone 54 Continuous tone, Finland (all-clear signal) 55 Continuous tone, PFEER gasalarm 56Continuous tone 57 Continuous tone, UK BS5839-1 59Continuous tone 60Continuous tone 61Continuous tone 1200 Hz 1 s EN54-3 500 Hz 970 Hz 1 s 800 Hz 970 Hz 20 ms 800 Hz 900 Hz 0.3 s 700 Hz 0.6 s 1200 Hz 3.5 s EN54-3 0.5 s 500 Hz 1200 Hz 3.75 s 0.25 s 500 Hz 775 Hz 0.85 s 422 Hz 1 s 1200 Hz 0.5 s 0.5 500 Hz s 1.5 s 2400 Hz 3 s const. 500 Hz 2400 Hz 3 s const. 300 Hz 800 Hz 3 s const. 300 Hz 1000 Hz 10 s 10 s 40 s 150 Hz 2900 Hz 0.5 s 2400 Hz 0.5 s 2900 Hz 10 ms 2400 Hz 10 ms 2900 Hz 70 ms 2400 Hz 70 ms 1600 Hz 1 s 1400 Hz 0.5 s 1000 Hz 0.5 s 800 Hz 0.5 s 1000 Hz 10 ms 800 Hz 10 ms 1000 Hz 70 ms 800 Hz 70 ms 1500 Hz 1.5 s 700 Hz 1.5 s 1200 Hz 1.5 s 500 Hz 1.5 s 1200 Hz 1 s 500 Hz 1 s 1200 Hz 3 s 500 Hz 3 s 1500 Hz 7 s 500 Hz 7 s 2400 Hz 2000 Hz 1500 Hz 1200 Hz 1000 Hz 950 Hz 880 Hz 825 Hz EN54-3 800 Hz 69Continuous tone 71Continuous tone 77 Interrupted tone 82 83 Interrupted tone, PFEER (general alarm), UK BS5839-1 (back-up alarm) Interrupted tone, PFEER (general alarm) 88 Interrupted tone 90 Interrupted tone 91 Interrupted tone 92 Interrupted tone 93 Interrupted tone (fast), electromechanical horn 97 Interrupted tone 98 100 101 102 103 104 107 109 110 111 112 113 Interrupted tone, Sweden SS031711 (emergency signal) Interrupted tone, industrial alarm (Germany) Interrupted tone, Sweden SS031711 (important message (pres-mess)) Interrupted tone, Sweden SS031711 (local warning) Interrupted tone, Sweden SS031711 (air raid warning) Interrupted tone, Sweden SS031711 (emergency signal) Interrupted tone, Germany KTA3901 (evacuation alarm) Interrupted tone, Australia AS2220, AS1610, AS1670 Interrupted tone, (fast variable), bell Interrupted tone, ISO8201 (emergency evacuation signal), USA (evacuation alarm) Interrupted tone, ISO8201 (emergency evacuation signal) Interrupted tone, ISO8201 (emergency evacuation signal), sweeping 115 Interrupted tone, IMO (telephone call) 116 Interrupted tone, IMO (leave ship) 117 Interrupted tone, IMO SOLAS III/50 + SOLAS III/6.4 (general alarm) 122 Alternating tone 123 Alternating tone 124 Alternating tone, Singapore 125 Alternating tone 128 Alternating tone 440 Hz 340 Hz 2400 Hz 0.5 s 0.5 s 1000 Hz 0.5 s 0.5 s 1000 Hz 1 s 1 s 950 Hz 1 s 1 s 825 Hz 0.5 s 0.5 s 800 Hz 0.25 s 0.25 s 800 Hz 1 s 800 Hz 4 ms 4 ms 725 Hz 0.7 s 0.3 s 700 Hz 0.125 s 0.125 s 680 Hz 0.875 s 0.875 s 660 Hz 6.5 s 13 s 660 Hz 0.5 s 0.5 s 660 Hz 1.8 s 1.8 s 660 Hz EN54-3 0.25 s 150 ms 150 ms 500 Hz 0.75 s 420 Hz 0.625 s 0.625 s 1450 Hz 0.5 s 0.5 s 0.5 s 0.5 s 0.5 s 0.5 s 0.25 s 0.69 ms 470 Hz 1.5 s 950 Hz 1.5 s 2850 Hz 1.5 s 950 Hz 2 s 1 s 950 Hz 1 s 3 s 0.5 s 0.5 s 1 s 1 s 2.5 s 825 Hz 7 s 2.5 s 2900 Hz 0.5 s 2400 Hz 0.5 s 2900 Hz 0.25 s 2400 Hz 0.25 s 2000 Hz 0.5 s 1000 Hz 0.5 s 1400 Hz 20 ms 1200 Hz 20 ms 1025 Hz 0.25 s 825 Hz 0.25 s 63Continuous tone 65 Continuous tone, Sweden SS031711 (all-clear signal) 66Continuous tone 67 Continuous tone, Germany KTA3901 (all-clear signal) 68Continuous tone 725 Hz 660 Hz 554 Hz 500 Hz 470 Hz 130 Alternating tone, UK BS5839-1 (fi re alarm) 131 135 Alternating tone, UK BS5839-1 (fi re alarm, railway crossing) Alternating tone, UK BS5839-1 (fi re alarm, increased urgency - railway crossing) 142 Alternating tone 1000 Hz 0.5 s 800 Hz 0.5 s 1000 Hz 0.25 s EN54-3 800 Hz 0.25 s 1000 Hz 0.125 s 800 Hz 0.125 s 900 Hz 0.25 s 500 Hz 0.25 s 140 www.pfannenberg.com

Tone table PA 1 / PA 5 / PA 10 / PA 20 Basic tone no. Description Basic tone no. Description 143 Alternating tone, industrial alarm (Germany) 660 Hz 440 Hz 0.125 s 0.125 s 147 Alternating tone, Sweden SS031711 554 Hz 440 Hz 1 s 1 s 144 Alternating tone 650 Hz 440 Hz 1 s 1 s 148 Alternating tone, Sweden SS031711 554 Hz 440 Hz 0.5 s 0.5 s 146 Alternating tone, France NFS 32-001 (fi re alarm) 554 Hz 440 Hz 0.1 s 0.4 s EN54-3 152 Alternating tone (two tone chime) 800 Hz 0.25 s 0.25 s 650 Hz 2 s Control of the tones Tone selection switch/dip-switch External tone selection (setting of basic tone) C1 C2 C1+C2 Basic tone 1 2 3 4 5 6 no. Tone no. 1 2 88 57 ON 2 * 128 112 57 ON 2 26 100 93 ON ON 2 61 131 112 ON 9 57 11 82 ON ON 15 131 52 112 ON ON 16 109 52 56 ON ON ON 18 111 57 68 ON 22 16 109 68 ON ON 23 131 52 112 ON ON 24 131 52 131 ON ON ON 25 131 52 92 ON ON 26 2 100 93 ON ON ON 27 123 52 92 ON ON 29 35 52 61 ON ON ON 30 27 52 77 ON 31 131 52 57 ON ON 33 30 52 35 ON ON 34 35 52 93 ON ON ON 35 27 52 110 ON ON 36 146 67 57 ON ON ON 43 131 52 91 ON ON ON 45 2 57 93 ON ON ON ON 52 15 65 82 ON ON 54 46 54 131 ON ON ON 55 131 52 128 ON ON ON 56 82 35 33 ON ON ON ON 59 143 59 101 ON ON 60 131 52 125 ON ON ON ON 65 131 52 93 ON ON ON ON 66 110 52 107 ON ON ON ON ON 69 131 52 110 * factory setting Tone selection switch/dip-switch External tone selection (setting of basic tone) C1 C2 C1+C2 Basic tone 1 2 3 4 5 6 no. Tone no. ON 71 131 52 93 ON ON 77 61 52 122 ON ON 82 131 52 83 ON ON ON 83 56 2 82 ON ON 88 2 57 128 ON ON ON 90 131 52 125 ON ON ON 91 30 52 110 ON ON ON ON 92 33 52 57 ON ON 93 2 128 57 ON ON ON 97 2 63 93 ON ON ON 100 131 52 125 ON ON ON ON 101 98 102 65 ON ON ON 103 131 65 147 ON ON ON ON 104 103 65 101 ON ON ON ON 109 16 52 22 ON ON ON ON ON 110 131 61 91 ON ON 112 2 57 128 ON ON ON 113 52 123 104 ON ON ON 115 117 116 44 ON ON ON ON 116 117 93 125 ON ON ON 117 93 116 125 ON ON ON ON 123 27 52 77 ON ON ON ON 124 53 83 2 ON ON ON ON ON 130 2 107 67 ON ON ON 131 2 112 57 ON ON ON ON 135 16 56 109 ON ON ON ON 142 2 54 88 ON ON ON ON ON 143 59 93 33 ON ON ON ON 144 110 61 2 ON ON ON ON ON 146 31 67 57 ON ON ON ON ON 148 131 52 92 ON ON ON ON ON ON 152 110 61 13 Sounders ACCESSORIES Ordering details Article numbers PA 1 PA 5 PA 10 / PA 20 Enclosure fitting Surface gasket Tamper-proof sealing (pack of 4) Panel mount installation kit PATROL For connection (daisy-chaining) of several sounders of the PATROL series Sealing of the sounder installation surface when, e.g. cable entry is executed from the back. Anti-tamper sealing for fasteners of the PATROL devices after installation in order to prevent manipulation of the devices. The PATROL devices are also suitable for panel mounting. This kit consists of a plug connector for the electrical contact, as well as all installation materials. 283 00 00 0 003 283 00 00 0 004 283 00 00 0 005 283 00 00 0 006 283 00 00 0 002 283 00 00 0 007 283 00 00 0 008 283 00 00 0 009 Further technical information can be found on our website at www.pfannenberg.com 141

AUDIBLE SIGNALING DEVICES SOUNDER 130 db(a) PA 130 secure alarming in the loudest environments and over large areas also dimensioned for use as warning devices in civil defence with just one sounder, reaction to the most diverse alarm situations is possible by means of remote control of up to 9 of currently 80 pre-installed tones integrated self-monitoring, test function and malfunction message relay maintenance-free power-saving standby mode with automatic self-test function suitable for indoor and outdoor operation switchable 4.7 kohm terminal resistor for cable monitoring optionally available: voice transmisssion possible via audio input can be mounted in a cluster by means of stable mast holder r = 562 m max. covering distance IP 54 Protection system + 50 C - 20 C Operating temperature Electrical data PA 130 Rated voltage 230 V AC 20-60 V DC Rated frequency 50 / 60 Hz Operating range - 25% / + 15% 20 V 60 V Nominal current 1 A 4 A consumption in standby mode < 15 ma < 40 ma Malfunction message relay/auxiliary relay 0.5 A, 50 V / NO or NC potential free, confi gurable Mechanical data PA 130 Sound pressure level 130 db (A) Alarm tones 80, incl. DIN tone Remote controlled tones 9 tones, externally controllable Operating temperature - 20 C... + 50 C Storage temperature - 20 C... + 70 C Relative humidity 90% Protection system according to EN 60529 IP 54 Material housing - horn MOPLEN plastic, light grey housing - circuitry aluminium, painted in light grey Cable entry 2 x PG16 for simple series connection of up to 4 sounders Type of connection 2 x 2.5 mm 2 Weight AC 7.45 kg DC 5.85 kg 142 www.pfannenberg.com

Dimensions 622 490 190 390 Sounders 295 2 x PG16 40 5 50 50 40 3 x Ø 8.5 Ordering details Article numbers PA 130 Rated voltage 230 V AC 20 60 V DC 230 26 10 0 000 230 26 91 0 000 Options / Accessories GOST Further technical information can be found on our website at www.pfannenberg.com 143

AUDIBLE SIGNALING DEVICES SOUNDERS 105/110 db(a) DS 5-SIL / DS 10-SIL integrated safety tough demands under industrial conditions to signal dangerous situations in safety-relevant application such as process and plant safety, e.g. - leaks / gas warning - high-pressure / overfi lling and machine safety, e.g. as - start-up warning - excess rotation speed warning - machine stop delay warning by means of integrated self-monitoring of the devices the normative required, regular inspection of warning devices is ensured the warning devices can be implemented in Safety Instrumented Systems (SIS) up to SIL 2/PLd We would be more than happy to provide all safety-technical key data. DS 5-SIL DS 10-SIL r = 32 m r = 56 m IP 66 IP 67 + 55 C - 25 C 10 Years max. covering distance max. covering distance Protection system Operating temperature Acoustic penetration Warranty Electrical data DS 5-SIL DS 10-SIL Rated voltage230 V AC 115 V AC 24 V DC230 V AC 115 V AC 24 V DC Rated frequency 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz Operating range 195 253 V 95 127 V 19 29 V 195 253 V 95 127 V 19 29 V Nominal current consumption0.03 A 0.06 A 0.28 A0.06 A 0.12 A 0.42 A Diagnostics current consumption 15 ma 15 ma 20 ma 15 ma 15 ma 20 ma channel switching power 230 V / 80 ma Mechanical data DS 5-SIL DS 10-SIL Sound pressure level 105 db (A) 110 db (A) Alarm tones 32 (see tone table page 133) Operating temperature - 25 C... + 55 C Storage temperature - 40 C... + 70 C Relative humidity 90% Protection system according to EN 60529 IP 66, IP 67 Duty cycle 100% Material die-cast aluminium GD-AI Si12 Cu Surface coating epoxy resin paint RAL 3000, fl ame red Cable bushing 2 x M20 (1 x chrome-plated brass cable fi tting, 1 x chrome-plated brass blanking plug) Clamping range of the cable fitting 8 12 mm Connecting terminals max. 2.5 mm 2 Weight AC 2.15 kg DC 1.95 kg 144 www.pfannenberg.com

Dimensions Ø 7 143 M20 x 1.5 blanking plug M20 71.5 71.5 Safety-related Sounders 133.5 150 Ordering details Article numbers DS 5-SIL DS 10-SIL Version Rated voltage 230 V AC 24 V DC 230 V AC 24 V DC Standard 231 06 10 0 601 231 06 80 0 601 231 11 10 0 601 231 11 80 0 601 TAS (external tone selection via closed function of the control voltage) 231 06 10 0 603 231 06 80 0 603 231 11 10 0 603 231 11 80 0 603 Article numbers for other voltages and versions on request Options / Accessories External tone selection for controlling several tones over great distances GOST Conformity to standards The sounders fulfi ll the requirements to the functional safety according to: EN 61508 Functional safety of electrical/electronic/programmable electronic safety-related systems EN 61511 Functional safety - Safety instrumented systems for the process industry sector The devices can be used in safety related control systems in accordance with the following standards: EN ISO 13849-1 Safety of machinery - Safety related parts of control systems part 1 EN 62061 Safety of machinery - Functional safety of electrical/electronic/programmable electronic safety-related systems The devices conform to the following standards: EN 61310-1 Safety of machinery - Indication, marking and actuation - part 1: Requirements for visual, acoustic and tactile signals EN ISO 7731 Ergonomic alarms for public areas and workplaces acoustic alarms EN 981 Safety of machinery - System of acoustic and visual alarm signals and information signals DIN 33404-1 Alarms for workplaces, uniform emergency signal ISO 8201 Acoustics - Audible emergency evacuation signal Further technical information can be found on our website at www.pfannenberg.com 145

AUDIBLE SIGNALING DEVICES PANEL MOUNT BUZZERS P 22 DBZ / P 28 DMC / P 28 DMB acoustic signaling device for 22.5 mm and 28.6 mm mounting holes available with 2 different types of signals in one device (continuous and pulsating tone) guaranteed high protection class to the housing also availbale wih easily adjustable volume control P22 DBZ P28 series P22 DBZ P28 series r = 2 m r = 6 m IP 40 IP 65 + 50 C - 25 C max. covering distance max. covering distance Protection system Protection system Operating temperature Electrical data P 22 DBZ Rated voltage 24 V AC/DC 48 V AC/DC 115 V AC 230 V AC Nominal current consumption 15 30 ma Electrical data P 28 DMC948 P 28 DMC201 P 28 DMC301 P 28 DMB530 Rated voltage 48 V DC 110 V AC 230 V AC 30 V DC Operating range 9 V 48 V 30 V 120 V 130 V 230 V 5 V 30 V Nominal current consumption 5 ma @ 9 V 20 ma @ 48 V 7 ma @ 30 V 40 ma @ 120 V 20 ma @ 130 V 40 ma @ 220 V 2 ma @ 5 V 20 ma @ 30 V Mechanical data P 22 DBZ P 28 DMC948 P 28 DMC201 P 28 DMC301 P 28 DMB530 Operating modepulsating tone continuous tone continuous tone continuous tone continuous tone / pulsating tone Sound pressure level 80 db (A) @ 10 cm 91 db (A) @ 48 V 91 db (A) @ 120 V 91 db (A) @ 230 V 91 db (A) @ 30 V Sound level reduction up to 20 db Duty cycle > 50,000 hrs > 50,000 hrs Operating temperature - 25 C... + 50 C - 25 C... + 65 C Storage temperature - 40 C... + 85 C Relative humidity 90% @ + 20 C 90% @ + 40 C Protection system according to EN 60529 IP 40 IP 65 Material housing polycarbonate (PC) plastic NORYL N-190, UL 49-VO, black Mounting panel-mounting: Ø 22.5 mm panel-mounting: Ø 28.6 mm Type of connection screw terminals 1.5 mm 2 quick connect blades, 6.3 mm wide, 0.8 mm thick Weight 30 g 40 g 146 www.pfannenberg.com

Dimensions Panel cutouts P 22 DBZ Ø 29 49 13 max. 7 49 62 22.5 22 P 28 DMC948 / P 28 DMC201 / P 28 DMC301 Rear view Side view Ring Front view 10.9 22.6 8 35.8 Ø 28.6 25.4 ± 2.5 26.7 32.8 for mounting panels up to 6.3 mm thick Electronic buzzers 11.7 38.2 P 28 DMB530 Rear view Side view Ring Front view common plus 10.9 22.6 8 35.8 Ø 28.6 25.4 ± 2.5 26.7 32.8 for mounting panels up to 6.3 mm thick continuous tone minus pulsating tone minus 38.2 11.7 Ordering details Article numbers P 22 DBZ Rated voltage 24 V AC/DC 48 V AC/DC 115 V AC 230 V AC 232 70 80 0 000 232 70 70 0 000 232 70 15 0 000 232 70 10 0 000 Article numbers P 28 DMC948 P 28 DMC201 P 28 DMC301 P 28 DMB530 Rated voltage 48 V DC 110 V AC 230 V AC 30 V DC 232 60 70 0 000 232 60 16 0 000 232 60 11 0 000 232 65 80 0 000 Options / Accessories Label holder Article number: 232 92 00 0 000 25 x 10 mm only for P 22 DBZ Label holder Article number: 232 91 00 0 000 25 x 18 mm only for P 22 DBZ See page 85 for illustrations Further technical information can be found on our website at www.pfannenberg.com 147

AUDIBLE SIGNALING DEVICES CONNECTION DIAGRAMS DS 5 / DS 10 AC DS 5 / DS 10 DC operating voltage connection optional: volume control for DS 5 115 V AC 230 V AC L N PE L N PE X1 code switch for setting the tone optional: programming mode for external tone selection optional: external tone selection stage 2, 3 and 4 12-48 V DC 24 V AC X1 for the supply of additional sounders; max. 10 of type DS 10 or max. 15 of type DS 5 PA 130 connecting terminal (removable) audio input 0 db 600 Ω temperature sensor code switch II 1: audio: switch 1 to ON: activation of the terminal resistor (120 Ω) for cable monitoring - audio input 0 db 600 Ω 2: not used (normally set to OFF) 3: cable monitoring switch 3 to ON: activation of the resistor (4K7) for cable monitoring (DC devices only) 4: auxiliary relay switch 4 to ON: malfunction message output switch 4 to OFF: activation of additional devices external tone selection malfunction message-/ aux. relay NO/NC operating voltage 24 V (48 V DC) tone selection code switch I normally set to ON self-test: switch 7 to OFF: activation of the self-test every 24 hrs (operating voltage, amplifi er, driver, tone test - duration 2 s) 230 V AC Example for external tone selection Relay energised during trouble-free operation Factory setting connecting terminals NO NC L3-L5 L3 L4 L5 L6 LED s - OFF during troule-free operation operating voltage failure overheating driver not operating not used connecting terminal AC version setting of code switch I according to line 59 Customer application Tone SW1 SW2 SW3 SW4-51 x 52 x 53 x 54 x audio x x 55 x x x x 56 x x x = closed 148 www.pfannenberg.com

DS 5-SIL / DS 10-SIL X1 Sounder channel X2 optional external tone selection (option -TAS or -TAV) 1 PE 2 PE 3 L/+ Operating voltage 4 L/+ Operating voltage 5 N/- Operating voltage 6 N/- Operating voltage 1 L/+ Stage S2 2 L/+ Stage S2 3 L/+ Stage S3 4 L/+ Stage S3 X1 Monitoring channel 1 L/+ Operating voltage 2 L/+ Operating voltage 3 N/- Operating voltage 4 N/- Operating voltage 5 Alarm relay (MOS-Relay 230V~, 80mA, 35Ω, 6 Alarm relay conductive, if function 7 Alarm relay channel is acoustically 8 Alarm relay active) PA 1 / PA 5 C2 C1 C1 -L -L operating voltage connection electrical connection and tone selection through external control of C1 and C2 N L + DC: C2 +N AC: X2 +N S3 S2 S1 tone selection switch -+ S1 (by-passing the reverse polarity diode) Caution: Position of changeover switch S2 only at - or + open position is not permitted and leads to malfunction. S2 (selection of the polarity of the control voltage for C1 and C2) + open closed Connection diagrams volume control Note: In order to conform to EN54-3, the volume control must be set to the maximum position factory setting PA 10 / PA 20 C2 +N electrical connection and tone selection through external control of C1 and C2 S2 (by-passing the reverse polarity protection diode) -L operating voltage connection N L + DC: C2 C1 -L AC: X2 C1 +N DC + AC with reverse polarity protection (factory setting) S2 - without reverse polarity protection + volume control Note: In order to conform to EN54-3, the volume control must be set to the maximum position S3 - S3 S1 tone selection switch S1 (selection of the polarity of the control voltage for C1 and C2) factory setting Further technical information can be found on our website at www.pfannenberg.com + 149

COMBINED VISUAL-AUDIBLE SIGNALING DEVICES 150 www.pfannenberg.com

SEEING AND HEARING DOUBLE ALARMS WARN BETTER! VISUAL-AUDIBLE SIGNALING DEVICES OFFER DOUBLE THE AMOUNT OF SAFETY IN ONE PACKAGE Visual-audible signaling devices There are many industrial areas of use for signaling devices that are associated with adverse environmental conditions and higher demands, making the mutual assistance of acoustic and visual signals necessary. For example, when signals need to be noticed at great distances. Two scenarios make this clear. Visual signals, for example, are easily recognisable in the dark. However, as soon as there is sunlight, other lights, the factory lighting or welding fl ashes, the observer is faced with a barely distinguishable light smog. Therefore, acoustic assistance of the visual signal is necessary. The same applies to acoustic signals that have to penetrate through machine noise, environmental noise, voice noise, echoes, running motors and hearing protection. They are only reliable in being noticed with visual assistance. Further technical information can be found on our website at www.pfannenberg.com 151

COMBINED VISUAL-AUDIBLE SIGNALING DEVICES ALL VISUAL-AUDIBLE SIGNALING DEVICES AT A GLANCE Type Maximum covering distance for a 65 db ambient noise level in in metres (m) 1 Sound pressure level (tone) / Light power Protection system Dimensions (HxWxD) mm 2.5 5 25 75 150 MED GL Approvals / Standards GOST UL EN 54-3 VdS EN 54-23 Page P 22 DBF 80 db (A) @ 10 cm IP 40 Ø 29 x 52 153 SON 4 SON 4L 100 db (A) 0.25 J 100 db (A) IP 56 86 x 86 x AC: 120 DC: 102 154 NEW PY X-MA-05 PY X-MA-10 100 db (A) 5 J 100 db (A) 10 J IP 66 IK 08 134.2 x 166 x 114 156 DSF 5 DSF 10 105 db (A) 13 J 110 db (A) 13 J IP 66 IP 67 263.5 x 133.5 x 143 158 2 PA X 1-05 100 db (A) 5 J IP 66 IK 08 172.4 x 109.5 x 80.6 2 160 PA X 5-05 PA X 5-10 105 db (A) 5 J 105 db (A) 10 J IP 66 IK 08 215 x 163.4 x 132 2 2 160 PA X 10-10 PA X 10-15 110 db (A) 10 J 110 db (A) 15 J IP 66 IK 08 270 x 214 x 156 2 2 162 PA X 20-10 PA X 20-15 120 db (A) 10 J 120 db (A) 15 J IP 66 IK 08 270 x 214 x 181 2 2 162 1 The specifi cation for the alarm signal reception range assumes an existing ambient noise level of 65 db (A). In accordance with applicable regulations, the calculated alarm range for the sound level 65 db (A) was given + 10 db (A) = 75 db (A). available in preparation 2 option Note: Using sounders with a sound pressure level of 120 db (A) can lead to hearing damage. People must not be permitted to stay in the near vicinity of the sounder. All specifi ed sound pressure levels are based on a measurement distance of 1 m, provided that nothing different is specifi ed. Further information can be found on the Internet: www.pfannenberg.com www.pfannenberg-spareparts.com Keep up to date. Subscribe to our newsletter now: newsletter.pfannenberg.com 152 www.pfannenberg.com

BLINKING LED PANEL MOUNT INDICATOR WITH BUZZER P 22 DBF indicator lamp/buzzer combination for 22.5 mounting hole guaranteed high protection class to the housing superior shape, hence high signaling effect on all sides space-saving combination of buzzer and blinking LED indicator for increasing the effect of the signal easy to mount label holders available as an accessory simple electrical connection by means of screw terminals r = 2 m Covering distance as per EN 54 IP 40 Protection system + 50 C - 25 C Operating temperature Electrical data P 22 DBF Rated voltage 230 V AC 115 V AC 48 V AC/DC 24 V AC/DC Nominal current consumption max. 30 ma Mechanical data P 22 DBF Operating mode 1 Hz blinking light with buzzer (pulsating tone) Sound pressure level 80 db (A) @ 10 cm Light sourceled array Service life of light source > 50,000 hrs Lens colours red Operating temperature - 25 C... + 50 C Relative humidity 90% @ + 20 C Protection system according to EN 60529 IP 65 (to housing) Mounting panel-mounting: Ø 22.5 mm Type of connection screw terminals 1.5 mm 2 Weight 90 g Dimensions Panel cut-out Visual-audible signaling devices 29 49 13 max. 7 49 62 22.5 22 Ordering details Article numbers Lens colour Rated voltage 230 V AC 115 V AC 48 V AC/DC 24 V AC/DC red 232 72 10 5 000 232 72 15 5 000 232 72 70 5 000 232 72 80 5 000 Options / Accessories Label holder 25 x 10 mm Label holder 25 x 18 mm See page 85 for illustrations Article number: 232 92 00 0 000 Article number: 232 91 00 0 000 Further technical information can be found on our website at www.pfannenberg.com 153

COMBINED VISUAL-AUDIBLE SIGNALING DEVICES FLASHING SOUNDER 100 db(a) / 0.25 J SON 4 LED BLINKING SOUNDER 100 db(a) SON 4L automatic synchronisation in system mode volume control reverse polarity protection choice of 32 different tones 2 additional externally selectable tones ideal for fi re alarm systems due to low power consumption r = 18 m IP 56 + 55 C - 25 C EN 54-3 VdS G209080 Covering distance Protection system Operating temperature Electrical data SON 4 Rated voltage230 V AC 115 V AC 24 V AC 24 V DC Rated frequency 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz Operating range ± 10% ± 10% ± 10% ± 25% Nominal current consumption 30 ma 50 ma 180 ma 150 ma Electrical data SON 4L Rated voltage230 V AC 115 V AC 24 V AC 48 V DC 24 V DC 12 V DC Rated frequency 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz Operating range ± 10% ± 10% ± 10% ± 25% ± 25% ± 25% Nominal current consumption 20 ma 25 ma 60 ma 40 ma 50 ma 50 ma Mechanical data SON 4 SON 4L Sound pressure level 100 db (A) Alarm tones 32 / 3-stage alarm Sound level reduction by - 2 / - 6 db by - 9 db Flash energy 0.25 J Flashing / Blinking rate 1 Hz 2 Hz Light source xenon fl ash tube 5 high output LEDs Lens colour yellow, amber, red, green, blue amber, red Operating temperature - 25 C... + 55 C Storage temperature - 40 C... + 70 C Relative humidity 90% Protection system according to EN 60529 IP 56 Duty cycle 100% Material lens polycarbonate (PC) housing UL 94 VO & 5VA classifi ed ABS Housing colour RAL 3000 (fl ame red), optionally grey or white Cable entry 4 knock-outs prepared on the side and bottom Connecting terminals 0.5 2.5 mm 2 Weight AC: 400 g / DC: 300 g Dimensions SON 4 / SON 4L AC SON 4 / SON 4L DC 86 86 86 120 86 102 154 www.pfannenberg.com

Tone table SON 4 Stage Tone Description - Frequency 2 3 1 Continuous tone 340 Hz 2 5 2 3 Alternating tone, UK BS5839-1 (fi re alarm, railway crossing) Slow whoop, evacuation alarm Netherlands NEN 2575 17 5 2 5 4Sweeping (fast) 6 5 5Continuous tone 2400 Hz 3 20 6Sweeping 7 5 7Sweeping (fast) 10 5 8Sweeping 2 5 9 Sawtooth, DIN tone 33404-3 Germany (emergency signal), PFEER PTAP 1000 Hz 0.25 s 800 Hz 15 2 10Alternating tone 7 5 11Interrupted tone 2 5 12Alternating tone 4 5 13Interrupted tone 15 5 14Interrupted tone 4 5 15Continuous tone 800 Hz 2 5 16Interrupted tone 18 5 1200 Hz 500 Hz 3.5 s 1000 Hz 0.25 s 0.5 s 800 Hz 10 ms 2900 Hz 10 ms 70 ms 2400 Hz 70 ms 2900 Hz 10 ms 2400 Hz 10 ms 1200 Hz 3 s EN54-3 EN54-3 500 Hz 3 s 1200 Hz 1 s EN54-3 500 Hz 2900 Hz 20 ms 2400 Hz 20 ms 1000 Hz 10 ms 10 ms 1000 Hz 0.875 s 800 Hz 0.875 s 2400 Hz 800 Hz 660 Hz 0.25 s 10 ms 10 ms 1 s 150 ms 150 ms EN54-3 Tone 17 18 Alternating tone, France NFS 32-001 (fi re alarm) Description - Frequency Interrupted tone, Sweden SS031711 (air raid warning) Stage 2 3 2 27 2 5 19 Sweeping, France NFC48-265 2 5 20 Continuous tone, Sweden SS031711 (all-clear signal) 2 5 21Alternating tone 2 5 22Interrupted tone 2 5 23Interrupted tone 6 5 24 Sweeping (medium), UK BS5839-1 29 5 25Sweeping 29 5 26Simulated bell 2 15 27Continuous tone 800 Hz 26 5 28Continuous tone 440 Hz 2 5 29 Sweeping (fast), UK BS5839-1 7 5 30 Interrupted tone, Australia AS2220, AS1610, AS1670 32 26 31Sweeping 26 5 32 Slow whoop, Australian evacuation alarm AS2220 554 Hz 0.1 s 440 Hz 660 Hz 1.8 s 1.8 s 1600 Hz 1400 Hz 1 s 0.5 s 660 Hz 554 Hz 440 Hz 544 Hz 800 Hz 20 ms 20 ms 1000 Hz 0.5 s 800 Hz 0.5 s 2900 Hz 0.5 s 2400 Hz 0.5 s 1450 Hz 1000 Hz 800 Hz 70 ms 420 Hz 0.4 s 10 ms 0.875 s 0.875 s 0.69 ms 70 ms 0.625 s 0.625 s 1200 Hz 10 ms 660 Hz 10 ms 1200 Hz 3.75 s 0.25 s 500 Hz 10 ms EN54-3 30 26 Visual-audible signaling devices Tone table SON 4L Tone Description - Frequency Stage 2 Tone Description - Frequency Stage 2 1 2 3 4 Alternating tone, UK BS5839-1 (fi re alarm, railway crossing) Slow whoop, evacuation alarm Netherlands NEN 2575 Sawtooth, DIN tone 33404-3 Germany (emergency signal), PFEER PTAP Alternating tone, France NFS 32-001 (fi re alarm) 1000 Hz 0.25 s 800 Hz 1200 Hz 500 Hz 1200 Hz 500 Hz 554 Hz 5Simulated bell 1 0.1 s 440 Hz 1450 Hz 3.5 s 0.25 s 0.5 s 0.4 s EN54-3 1 s EN54-3 0.69 ms EN54-3 EN54-3 8 1 8 9 6 Sweeping (fast), UK BS5839-1 8 7 Slow whoop, Australian evacuation alarm AS2220 1000 Hz 70 ms 800 Hz 70 ms 1200 Hz 3.75 s 0.25 s 500 Hz 8Continuous tone 1000 Hz - 9Continuous tone 554 Hz - 420 Hz Interrupted tone, 10 - Australia AS2220, AS1610, AS1670 0.625 s 0.625 s 10 Ordering details Article numbers SON 4 SON 4L Lens colour Rated voltage 230 V AC 115 V AC 24 V DC 230 V AC 115 V AC 24 V DC amber 232 40 10 4 010 232 40 15 4 010 232 40 80 4 010 232 41 10 4 010 232 41 15 4 010 232 41 80 4 010 red 232 40 10 5 010 232 40 15 5 010 232 40 80 5 010 232 41 10 5 010 232 41 15 5 010 232 41 80 5 010 Article numbers for other voltages and versions on request Further technical information can be found on our website at www.pfannenberg.com 155

COMBINED VISUAL-AUDIBLE SIGNALING DEVICES PYRA FLASHING LIGHT SOUNDERS 100 db(a) / 5/10 J PY X-MA-05 / PY X-MA-10 NEW safe - an incorrect installation is virtually impossible easy - signifi cantly shorter assembly and installation n times economical - largest possible signaling range due to effective XENON technology installation options with external lugs or internal holes choice of four different fl ash rates via DIP switch electronic constant current regulation at 24 V AC/DC devices to avoid load fl uctuations integrated inrush current limitation and undervoltage detection providing full synchronization on multi-flashing light systems light and sounder can be controlled separately PY X-MA-05 PY X-MA-10 r = 11 m r = 17 m IP 66 IK 08 + 55 C - 40 C Sync UL 10 Years Visual covering distance Protection system Impact-proof housing Operating temperature pending Warranty Electrical data Mechanical data PY X-MA-05 PY X-MA-10 Sound pressure level 100 db (A) Sound level reduction max. - 20 db via potentiometer Alarm tones 8 Flash energy 5 J 10 J Flash rate 0.1 / 0.5 / 0.75 / 1 Hz (DIP switch) Light intensity (DIN 5037) 1 44 cd 118 cd Operating temperature - 40 C... + 55 C Storage temperature - 40 C... + 70 C Relative humidity 90% Protection system according to EN 60529 IP 66 Protection class II Duty cycle 100% Service life of the flash tube light emission still 70% after 8,000,000 fl ashes Material base part PC / ABS lens fl ashing light polycarbonate (PC) Housing colour RAL 3000 (fl ame red) / RAL 7035 (light grey) Lens colour clear, white, yellow, amber, red, green, blue Cable entry 2 x M20 on side, 1 x M20 on bottom Integrated seal with cable entry 6 13 mm Connecting terminals 2.5 mm 2 fi ne wire, AWG 16 Weight AC 620 g 660 g AC/DC 560 g 580 g 1 with a clear lens PY X-MA-05 Rated voltage230 V AC 115 V AC 24 V AC/DC Rated frequency 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz / DC Operating range 187 255 V 90 135 V AC: 18 30 V / DC: 10 60 V Nominal current consumption 1 70 75 ma 120 140 ma AC: 660 720 ma DC: 280 ma @ 24 V Electrical data PY X-MA-10 Rated voltage230 V AC 115 V AC 24 V AC/DC Rated frequency 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz / DC Operating range 187 255 V 90 135 V AC: 18 30 V / DC: 10 60 V Nominal current consumption 1 160 165 ma 250 270 ma AC: 1050 1150 ma DC: 550 620 ma @ 24 V 1 power consumption dependent on operating voltage 156 www.pfannenberg.com

Dimensions SW10 105 30.5 12 10 134 47 50 32 Ø 22 85 14.5 172 166 114 M20 knock-outs prepared Ø 6 Ø 5 125 28 Ø 7 154 154 Tone table Tone no. Description Tone no. Description 1 Sawtooth, DIN tone 33404-3 Germany (emergency signal), PFEER PTAP 2 Continuous tone (horn) 3Continuous tone 4 Interrupted tone 1200 Hz 1 s 500 Hz 110 Hz 3000 Hz 3000 Hz 0.5 s 0.5 s 5 Interrupted tone 6 Slow whoop, fi re alarm, UK BS5839-1 7 Slow whoop 8 Alternating tone, UK BS5839-1 (fi re alarm, railway crossing) 3000 Hz 25 ms 25 ms 970 Hz 1 s 800 Hz 2850 Hz 143 ms 2400 Hz 1000 Hz 0.25 s 800 Hz 0.25 s Visual-audible signaling devices Ordering details Article numbers PY X-MA-05 housing red PY X-MA-05 housing grey Version Rated voltage 230 V AC 115 V AC 24 V AC/DC 230 V AC 115 V AC 24 V AC/DC clear lens 215 54 10 1 000 215 54 15 1 000 215 54 81 1 000 215 54 10 1 055 215 54 15 1 055 215 54 81 1 055 yellow lens 215 54 10 3 000 215 54 15 3 000 215 54 81 3 000 215 54 10 3 055 215 54 15 3 055 215 54 81 3 055 red lens 215 54 10 5 000 215 54 15 5 000 215 54 81 5 000 215 54 10 5 055 215 54 15 5 055 215 54 81 5 055 Article numbers PY X-MA-10 housing red PY X-MA-10 housing grey Version Rated voltage 230 V AC 115 V AC 24 V AC/DC 230 V AC 115 V AC 24 V AC/DC clear lens 215 55 10 1 000 215 55 15 1 000 215 55 81 1 000 215 55 10 1 055 215 55 15 1 055 215 55 81 1 055 yellow lens 215 55 10 3 000 215 55 15 3 000 215 55 81 3 000 215 55 10 3 055 215 55 15 3 055 215 55 81 3 055 red lens 215 55 10 5 000 215 55 15 5 000 215 55 81 5 000 215 55 10 5 055 215 55 15 5 055 215 55 81 5 055 Article numbers for other voltages and versions on request Options / Accessories Surface gasket Tamperproof sealing See page 165 for further information Conformity to standards The acoustic parameters conform to the European standard DIN EN ISO 7731; Ergonomic alarm signals for public areas and workplaces acoustic alarm signals. The requirement for an acoustic alarm signal can be found in the harmonised standards: EN 60204-1 Electrical equipment of machines EN 60825-1 Radiation safety of laser devices, identical to IEC 825 and DIN-VDE 0837 Further technical information can be found on our website at www.pfannenberg.com 157

COMBINED VISUAL-AUDIBLE SIGNALING DEVICES FLASHING SOUNDERS 105/110 db(a) / 13 J DSF 5 / DSF 10 The powerful fl ashing sounders extremely bright and loud due to 13 joules, 105 db (A) or 110 db (A) high reliability and long service life 31 different sound signals can be set up to four externally selectable tones (optional) Further detailed specifications for the Quadro flashing light on page 54. DSF 5 DSF 10 r = 32 m r = 56 m IP 66 IP 67 + 55 C - 40 C 10 Years Covering distance Protection system Protection system Operating temperature Acoustic penetration Warranty Electrical data DSF 5 DSF 10 Rated voltage230 V AC 115 V AC 24 V DC230 V AC 115 V AC 24 V DC Rated frequency 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz Operating range 195 253 V 95 127 V 19 29 V 195 253 V 95 127 V 19 29 V Nominal current consumption0.19 A 0.40 A 0.98 A0.22 A 0.46 A 1.12 A Mechanical data DSF 5 DSF 10 Sound pressure level 105 db (A) 110 db (A) Alarm tones 32 / 2-stage alarm Flash energy 13 J Lens colour clear, yellow, amber, red, green, blue Operating temperature - 40 C... + 55 C Storage temperature - 40 C... + 70 C Relative humidity 90% Protection system according to EN 60529 IP 66, IP 67 Impact resistance of the flashing light IK 08 (as per EN 50102) Duty cycle 100% Service life of light source light emission still 70% after 8,000,000 fl ashes Material sounder die-cast aluminium GD-AI Si12 Cu fl ashing light polycarbonate (PC) Surface coating sounder epoxy resin paint RAL 3000, fl ame red Cable bushing 2 x M20 x 1.5 Clamping range of the cable fitting 8 12 mm Connecting terminal cross-section max. 2.5 mm 2 Mounting do not direct the opening of the sound horn upwards Weight 2.6 kg Ordering details Article numbers DSF 5 DSF 10 Version Rated voltage 230 V AC 115 V AC 24 V DC 230 V AC 115 V AC 24 V DC Standard; red lens 231 07 10 5 000 231 07 15 5 000 231 07 80 5 000 231 12 10 5 000 231 12 15 5 000 231 12 80 5 000 TAS (external tone selection); red lens 231 07 10 5 152 231 07 15 5 152 231 07 80 5 152 231 12 10 5 152 231 12 15 5 152 231 12 80 5 152 Options / Accessories External tone selection (4 variants) GOST 158 www.pfannenberg.com

Dimensions 130 113.5 130 113.5 143 M20 x 1.5 150 Ø 7 blanking plug M20 133.5 150 71.5 71.5 Tone table Description - Basic tone Stage Tone (preset: tone no. 1) 2 3 4 0 no tone 1 5 4 1 1 Sawtooth, DIN tone 33404-3 Germany (emergency signal), PFEER PTAP 2 Interrupted tone, ISO 8201 (emergency evacuation signal) 3 2 4 1 4 3 3 Alternating tone 1 2 4 4 Continuous tone, UK BS5839-1 950 Hz 1 3 5 5 Interrupted tone 1 4 3 6 Sweeping 1 4 9 7 8 Alternating tone, France NFS 32-001 (fi re alarm) Interrupted tone, Sweden SS031711 (emergency signal) 3 10 4 2 3 4 9 Interrupted tone (fast), horn 1 3 4 10 Continuous tone 500 Hz 27 9 26 11 Continuous tone 725 Hz 1 17 9 12 Continuous tone 825 Hz EN54-3 27 9 26 13 Continuous tone 1200 Hz 1 5 3 14 Continuous tone 1500 Hz 1 4 10 15 Interrupted tone 1 24 12 16 Interrupted tone 1 24 15 17 Interrupted tone 1 11 9 1 factory setting 1200 Hz 500 Hz 950 Hz 1025 Hz 825 Hz 950 Hz 1 s EN54-3 1 s 1 s 1200 Hz 3 s 500 Hz 3 s 554 Hz 440 Hz 0.4 s 700 Hz 800 Hz 500 Hz 825 Hz 725 Hz 0.5 s 0.5 s 0.1 s 0.25 s 1.5 s 0.25 s 0.125 s 0.125 s 4 ms 4 ms 0.5 s 0.5 s 0.5 s 0.5 s 0.7 s 0.3 s EN54-3 Tone Description - Basic tone (preset: tone no. 1) Stage 2 3 4 18 Interrupted tone 19 7 4 19 20 21 22 Alternating tone, UK BS5839-1 (fi re alarm, railway crossing) Interrupted tone, IMO SOLAS III/50 + SOLAS III/6.4 (general alarm) Interrupted tone, IMO (leave ship) Slow whoop, evacuation alarm Netherlands NEN 2575 27 13 23 9 21 26 20 9 26 19 14 2 23 Siren 27 12 2 24 Alternating tone 1 16 12 25 Alternating tone 1 14 5 26 Alternating tone 4 9 27 27 Siren 13 23 19 28 Sweeping 7 10 4 29 30 Pulsating tone, industrial alarm Germany Interrupted tone, industrial alarm (Germany) 1 30 9 1 4 26 31 Sweeping, France NFC48-265 3 14 4 32 selection of available tone combinations in stages 2, 3 and 4 800 Hz 2.5 s 825 Hz 950 Hz 1200 Hz 500 Hz 2.5 s 0.25 s 1000 Hz 0.25 s 800 Hz 1 s 3.5 s 3 s 7 s 1 s 1 s 0.5 s 1 s 0.25 s EN54-3 EN54-3 2400 Hz 3 s const. 500 Hz 1075 Hz 0.5 s 825 Hz 0.5 s 900 Hz 0.25 s 500 Hz 1400 Hz 0.25 s 20 ms 1200 Hz 20 ms 1200 Hz 3 s const. 300 Hz 1500 Hz 1.5 s 700 Hz 1.5 s 1000 Hz 10 s 40 s 150 Hz 680 Hz 0.875 s 0.875 s 1600 Hz 1 s 1400 Hz 0.5 s 10 s Visual-audible signaling devices Conformity to standards DIN EN 54-3: 2001 + DIN EN 54-3/A1: 2001 EN 50 130-4: 1996 EN 61 000-6-2 EN 61 000-6-3 EN 60 947-1: 2003 EN 60 529: 2000 Fire alarm systems - part 3: fire alarm devices; Audible signaling devices and annex A1 Stability of system components for fire and burglar alarm systems EMV, stability for industrial areas EMV, emission standard for residential commercial, and light-industrial environments Low voltage switchgear standard Protection system by enclosure (IP code) DIN EN ISO 7731 DIN 33 404/3: 1982 ISO 8201: 1987 DIN EN 981: 1997 ISO 11 429: 1996 Ergonomic alarms for public areas and workplaces acoustic alarms Alarms for workplaces, unified emergency signal Evacuation alarm System of acoustic and visual alarm signals and information signals System of acoustic and visual alarm signals and information signals Further technical information can be found on our website at www.pfannenberg.com 159

COMBINED VISUAL-AUDIBLE SIGNALING DEVICES PATROL FLASHING SOUNDERS 100/105 db(a) / 5/10 J PA X 1-05 / PA X 5-05 / PA X 5-10 PATROL - the new generation of sounder/fl ashing light combinations. Three dimensional innovation; safe; an incorrect installation is virtually impossible easy; signifi cantly shorter assembly and installation times economical; extremely high efficiency and good penetration of acoustical obstacles significantly reduce the required number of sounders pre-wired sounder and light ex works corresponding light intensity available for every sound pressure level PA X 1 PA X 5 PA X 1 PA X 1 PA X 1 r = 18 m r = 32 m IP 66 IK 08 + 55 C - 40 C EN 54-3 EN 54-23 VdS UL 10 Years Covering distance Protection system Impact-proof housing Operating temperature Acoustic penetration 24 V DC, 48 V DC 24 V DC, 48 V DC 24 V DC, 48 V DC Warranty Electrical data PA X 1-05 Rated voltage230 V AC 115 V AC 24 V AC 48 V DC 24 V DC 12 V DC Rated frequency 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz Operating range 187 255 V 90 135 V 18 30 V 40 60 V 18 30 V 12 15 V Nominal current consumption 1 65 70 ma 110 130 ma 860 920 ma 190 150 ma 315 365 ma 610 625 ma Electrical data PA X 5 Rated voltage230 V AC 115 V AC 24 V AC 48 V DC 24 V DC 12 V DC Rated frequency 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz Operating range 187 255 V 90 135 V 18 30 V 40 60 V 18 30 V 12 15 V Nominal current consumption 1 5 J 65 70 ma 110 130 ma 860 920 ma 190 150 ma 315 365 ma 610 625 ma 10 J 150 155 ma 250 260 ma 1,460 1,520 ma 320 380 ma 565 620 ma 1,200 1,220 ma 1 power consumption dependent on operating voltage Mechanical data PA X 1-05 PA X 5-05 PA X 5-10 Sound pressure level 100 db (A) 105 db (A) 105 db (A) Sound level reduction max. - 16 db via potentiometer Alarm tones 80 (see tone table page 164/165) Flash energy 5 J 5 J 10 J Flash rate 1 Hz = 60 fl ashes/min. Light intensity (DIN 5037) 1 44 cd 47 cd 92 cd Operating temperature - 40 C... + 55 C Storage temperature - 40 C... + 70 C Relative humidity 90% Protection system according to EN 60529 IP 66 Protection class II Duty cycle 100% Service life of the flash tube light emission still 70% after 8,000,000 fl ashes Material sounder PC / ABS blend lens fl ashing light polycarbonate (PC) Housing colour similar to RAL 3000 (fl ame red) / RAL 7035 (light grey) / RAL 9003 (signal white) Lens colour clear, white, yellow, amber, red, green, blue Cable entry 3 x M20 knock-outs on side, 1 knock-out on back Integrated seal with cable entry 6 13 mm (feed-through grommet) Connecting terminals 2.5 mm 2 fi ne wire with cable end sleeve, AWG 16 Weight AC 725 g 983 g DC 560 g 800 g 1 with a clear lens 160 www.pfannenberg.com

Dimensions PA X 1-05 PA X 5-05 37 M20 knock-outs prepared Ø 6.3 22 135 86.4 172.4 Ø 7.3 215 143 163.4 98 109.5 80.6 132 Ordering details Article numbers PA X 1-05 housing red PA X 1-05 housing grey Version Rated voltage 230 V AC 115 V AC 24 V DC 230 V AC 115 V AC 24 V DC clear lens 233 11 10 1 000 233 11 15 1 000 233 11 80 1 000 ¹ 233 11 10 1 055 233 11 15 1 055 233 11 80 1 055 ¹ yellow lens 233 11 10 3 000 233 11 15 3 000 233 11 80 3 000 233 11 10 3 055 233 11 15 3 055 233 11 80 3 055 amber lens 233 11 10 4 000 233 11 15 4 000 233 11 80 4 000 233 11 10 4 055 233 11 15 4 055 233 11 80 4 055 red lens 233 11 10 5 000 233 11 15 5 000 233 11 80 5 000 ¹ 233 11 10 5 055 233 11 15 5 055 233 11 80 5 055 ¹ Article numbers PA X 5-05 housing red PA X 5-05 housing grey Version Rated voltage 230 V AC 115 V AC 24 V DC 230 V AC 115 V AC 24 V DC clear lens 233 51 10 1 000 233 51 15 1 000 233 51 80 1 000 233 51 10 1 055 233 51 15 1 055 233 51 80 1 055 yellow lens 233 51 10 3 000 233 51 15 3 000 233 51 80 3 000 233 51 10 3 055 233 51 15 3 055 233 51 80 3 055 amber lens 233 51 10 4 000 233 51 15 4 000 233 51 80 4 000 233 51 10 4 055 233 51 15 4 055 233 51 80 4 055 red lens 233 51 10 5 000 233 51 15 5 000 233 51 80 5 000 233 51 10 5 055 233 51 15 5 055 233 51 80 5 055 Article numbers for other voltages and versions on request ¹ version with EN 54-23 approval Visual-audible signaling devices Options / Accessories GL MED (PA X 1) CNBOP (PA X 1) Enclosure fitting Surface gasket Tamperproof sealing See page 165 for further information Conformity to standards The acoustic parameters conform to the European standard DIN EN ISO 7731; Ergonomic alarm signals for public areas and workplaces acoustic alarm signals. The requirement for an acoustic alarm signal can be found in the harmonised standards: EN 60204-1 Electrical equipment of machines EN 60825-1 Radiation safety of laser devices, identical to IEC 825 and DIN-VDE 0837 Further technical information can be found on our website at www.pfannenberg.com 161

COMBINED VISUAL-AUDIBLE SIGNALING DEVICES PATROL FLASHING SOUNDERS 110/120 db(a) / 10/15 J PA X 10-10 / PA X 10-15 / PA X 20-10 / PA X 20-15 PATROL - the new generation of sounder/fl ashing light combinations. Three dimensional innovation; safe; an incorrect installation is virtually impossible easy; signifi cantly shorter assembly and installation times economical; extremely high efficiency and good penetration of acoustical obstacles significantly reduce the required number of sounders pre-wired sounder and light ex works corresponding light intensity available for every sound pressure level PA X 10 PA X 20 r = 56m r = 178m IP 66 IK 08 + 55 C - 40 C UL 10 Years Covering distance Protection system Impact-proof housing Operating temperature Acoustic penetration Warranty Electrical data PA X 10 Rated voltage230 V AC 115 V AC 24 V AC 48 V DC 24 V DC 12 V DC Rated frequency 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz Operating range 187 255 V 90 135 V 18 30 V 40 60 V 18 30 V 12 15 V 10 J 160 215 ma 260 345 ma 1,650 2,300 ma 360 490 ma 665 935 ma 1,335 1,685 ma Nominal current consumption 1 15 J 210 265 ma 360 445 ma 1,650 2,300 ma 420 540 ma 765 1,035 ma 1,535 1,885 ma Electrical data PA X 20 Rated voltage230 V AC 115 V AC 24 V AC 48 V DC 24 V DC 12 V DC Rated frequency 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz Operating range 187 255 V 90 135 V 18 30 V 40 60 V 18 30 V 12 15 V 10 J 215 335 ma 340 560 ma 1,900 3,200 ma 495 800 ma 845 1,430 ma 1,220 1,690 ma Nominal current consumption 1 15 J 165 385 ma 440 660 ma 1,900 3,200 ma 545 850 ma 945 1,540 ma 1,520 1,890 ma 1 power consumption dependent on operating voltage Mechanical data PA X 10-10 PA X 10-15 PA X 20-10 PA X 20-15 Sound pressure level 110 db (A) 120 db (A) Sound level reduction max. - 12 db via potentiometer Alarm tones 80 (see tone table page 164/165) Flash energy 10 J 15 J 10 J 15 J Flash rate 1 Hz = 60 fl ashes/min. Light intensity (DIN 5037) 1 129 cd 190 cd 129 cd 190 cd Operating temperature - 40 C... + 55 C Storage temperature - 40 C... + 70 C Relative humidity 90% Protection system according to EN 60529 IP 66 Protection class II Duty cycle 100% Service life of the flash tube light emission still 70% after 8,000,000 fl ashes Material Housing colour Lens colour Cable entry sounder lens fl ashing light PC / ABS blend polycarbonate (PC) similar to RAL 3000 (fl ame red) / RAL 7035 (light grey) / RAL 9003 (signal white) clear, white, yellow, amber, red, green, blue 4 x M20 knock-outs on side, 1 knock-out on back Integrated seal with cable entry 6 13 mm (feed-through grommet) Connecting terminals 2.5 mm 2 fi ne wire with cable end sleeve, AWG 16 Weight AC 2,133 g 2,163 g 2,268 g 2,298 g DC 2,056 g 2,086 g 2,191 g 2,221 g 1 with a clear lens 162 www.pfannenberg.com

Dimensions PA X 10-10 / PA X 10-15 PA X 20-10 / PA X 20-15 Ø 9 270 190 214 37 170 100 214 37 Visual-audible signaling devices 37 170 100 26 156 26 37 181 Ordering details Article numbers PA X 10-10 PA X 20-15 Version Rated voltage 230 V AC 115 V AC 24 V DC 230 V AC 115 V AC 24 V DC clear lens housing red 233 61 10 1 000 233 61 15 1 000 233 61 80 1 000 233 72 10 1 000 233 72 15 1 000 233 72 80 1 000 yellow lens housing red 233 61 10 3 000 233 61 15 3 000 233 61 80 3 000 233 72 10 3 000 233 72 15 3 000 233 72 80 3 000 amber lens housing red 233 61 10 4 000 233 61 15 4 000 233 61 80 4 000 233 72 10 4 000 233 72 15 4 000 233 72 80 4 000 red lens housing red 233 61 10 5 000 233 61 15 5 000 233 61 80 5 000 233 72 10 5 000 233 72 15 5 000 233 72 80 5 000 yellow lens housing grey 233 61 10 3 055 233 61 15 3 055 233 61 80 3 055 233 72 10 3 055 233 72 15 3 055 233 72 80 3 055 amber lens housing grey 233 61 10 4 055 233 61 15 4 055 233 61 80 4 055 233 72 10 4 055 233 72 15 4 055 233 72 80 4 055 red lens housing grey 233 61 10 5 055 233 61 15 5 055 233 61 80 5 055 233 72 10 5 055 233 72 15 5 055 233 72 80 5 055 Article numbers for other voltages and versions on request Options / Accessories Enclosure fitting Surface gasket Tamperproof sealing I lim t See page 165 for further information GL SSM (only for 24 V DC) Conformity to standards The acoustic parameters conform to the European standard DIN EN ISO 7731; Ergonomic alarm signals for public areas and workplaces acoustic alarm signals. The requirement for an acoustic alarm signal can be found in the harmonised standards: EN 60204-1 Electrical equipment of machines EN 60825-1 Radiation safety of laser devices, identical to IEC 825 and DIN-VDE 0837 Further technical information can be found on our website at www.pfannenberg.com 163

COMBINED VISUAL-AUDIBLE SIGNALING DEVICES Tone table PA X 1 / PA X 5 / PA X 10 / PA X 20 Basic tone no. 1 no tone 2 9 Description Sawtooth, DIN tone 33404-3 Germany (emergency signal), PFEER PTAP Slow whoop, fi re alarm, UK BS5839-1 11 Interrupted tone (fast) 13 Interrupted tone 15 16 Slow whoop, evacuation alarm Netherlands NEN 2575 Slow whoop, Australian evacuation alarm AS2220 18 Slow whoop, NFPA 22 23 Siren 24 Siren 25 Siren 26 Pulsating tone, Australien alert AS1670, ISO8201 Pulsating tone, industrial alarm Germany 27Sweeping 29Sweeping (fast) 30Sweeping 31 Sweeping, France NFC48-265 33 Sweeping (medium), UK BS5839-1 34Sweeping (fast) 35 Sweeping (fast), UK BS5839-1 36Sweeping 43Sweeping 44 Sweeping, IMO 3d, Germany KTA3901 evacuation alarm 45Sweeping 46 Sweeping, general alarm Finland 52Continuous tone 53Continuous tone 54 Continuous tone, Finland (all-clear signal) 55 Continuous tone, PFEER gasalarm 56Continuous tone 57 Continuous tone, UK BS5839-1 59Continuous tone 60Continuous tone 61Continuous tone 63Continuous tone 65 Continuous tone, Sweden SS031711 (all-clear signal) 66Continuous tone 67 Continuous tone, Germany KTA3901 (all-clear signal) 68Continuous tone 1200 Hz 1 s EN54-3 500 Hz 970 Hz 1 s 800 Hz 970 Hz 20 ms 800 Hz 900 Hz 0.3 s 700 Hz 0.6 s 1200 Hz 3.5 s 0.5 s 500 Hz EN54-3 1200 Hz 3.75 s 0.25 s 500 Hz 775 Hz 0.85 s 422 Hz 1 s 0.5 s 1200 Hz 0.5 500 Hz s 1.5 s 2400 Hz 3 s const. 500 Hz 2400 Hz 3 s const. 300 Hz 800 Hz 3 s const. 300 Hz 1000 Hz 10 s 10 s 40 s 150 Hz 2900 Hz 0.5 s 2400 Hz 0.5 s 2900 Hz 10 ms 2400 Hz 10 ms 2900 Hz 70 ms 2400 Hz 70 ms 1600 Hz 1 s 1400 Hz 0.5 s 1000 Hz 0.5 s 800 Hz 0.5 s 1000 Hz 10 ms 800 Hz 10 ms 1000 Hz 70 ms 800 Hz 70 ms 1500 Hz 1.5 s 700 Hz 1.5 s 1200 Hz 1,5 s 500 Hz 1,5 s 1200 Hz 1 s 500 Hz 1 s 1200 Hz 3 s 500 Hz 3 s 1500 Hz 7 s 500 Hz 7 s 2400 Hz 2000 Hz 1500 Hz 1200 Hz 1000 Hz 950 Hz 880 Hz 825 Hz EN54-3 800 Hz 725 Hz 660 Hz 554 Hz 500 Hz 470 Hz Basic tone no. 69Continuous tone 71Continuous tone 77 Interrupted tone 82 83 Description Interrupted tone, PFEER (general alarm), UK BS5839-1 (back-up alarm) Interrupted tone, PFEER (general alarm) 88 Interrupted tone 90 Interrupted tone 91 Interrupted tone 92 Interrupted tone 93 Interrupted tone (fast), horn 97 Interrupted tone 98 100 101 102 103 104 107 109 110 111 112 113 Interrupted tone, Sweden SS031711 (emergency signal) Interrupted tone, industrial alarm (Germany) Interrupted tone, Sweden SS031711 (important message (pres-mess)) Interrupted tone, Sweden SS031711 (local warning) Interrupted tone, Sweden SS031711 (air raid warning) Interrupted tone, Sweden SS031711 (emergency signal) Interrupted tone, Germany KTA3901 (evacuation alarm) Interrupted tone, Australia AS2220, AS1610, AS1670 Interrupted tone, (fast variable), bell Interrupted tone, ISO8201 (emergency evacuation signal), USA (evacuation alarm) Interrupted tone, ISO8201 (emergency evacuation signal) Interrupted tone, ISO8201 (emergency evacuation signal), Sweeping 115 Interrupted tone, IMO (telephone call) 116 Interrupted tone, IMO (leave ship) 117 Interrupted tone, IMO SOLAS III/50 + SOLAS III/6.4 (general alarm) 122 Alternating tone 123 Alternating tone 124 Alternating tone, Singapore 125 Alternating tone 128 Alternating tone 130 Alternating tone, UK BS5839-1 (fi re alarm) 131 135 Alternating tone, UK BS5839-1 (fi re alarm, railway crossing) Alternating tone, UK BS5839-1 (fi re alarm, increased urgency - railway crossing) 142 Alternating tone 440 Hz 340 Hz 2400 Hz 0.5 s 0.5 s 1000 Hz 0.5 s 0.5 s 1000 Hz 1 s 1 s 950 Hz 1 s 1 s 825 Hz 0.5 s 0.5 s 800 Hz 0.25 s 0.25 s 800 Hz 0.25 s 1 s 800 Hz 4 ms 4 ms 725 Hz 0.7 s 0.3 s 700 Hz 0.125 s 0.125 s 680 Hz 0.875 s 0.875 s 660 Hz 6.5 s 13 s 660 Hz 0.5 s 0.5 s 660 Hz 1.8 s 1.8 s 660 Hz EN54-3 150 ms 150 ms 500 Hz 0.75 s 420 Hz 0.625 s 0.625 s 1450 Hz 470 Hz 950 Hz 2850 Hz 950 Hz 950 Hz 0,5 s 0.5 s 0.5 s 0,5 s 0.5 s 0.5 s 0.25 s 2 s 1 s 0.69 ms 1.5 s 1.5 s 1,5 s 0.5 s 0.5 s 3 s 1 s 1 s 2.5 s 825 Hz 7 s 2.5 s 2900 Hz 0.5 s 2400 Hz 0.5 s 2900 Hz 0.25 s 2400 Hz 0.25 s 2000 Hz 0.5 s 1000 Hz 0.5 s 1400 Hz 20 ms 1200 Hz 20 ms 1025 Hz 0.25 s 825 Hz 0.25 s 1 s 1000 Hz 0.5 s 800 Hz 0.5 s 1000 Hz 0.25 s EN54-3 800 Hz 0.25 s 1000 Hz 0.125 s 800 Hz 0.125 s 900 Hz 0.25 s 500 Hz 0.25 s 164 www.pfannenberg.com

Tone table PA X 1 / PA X 5 / PA X 10 / PA X 20 Basic tone no. 143 Alternating tone, industrial alarm (Germany) 144 Alternating tone 146 Alternating tone, France NFS 32-001 (fi re alarm) Description 660 Hz 0.125 s 440 Hz 0.125 s 650 Hz 1 s 440 Hz 1 s 554 Hz 440 Hz 0.1 s 0.4 s EN54-3 Basic tone no. Description 147 Alternating tone, Sweden SS031711 148 Alternating tone, Sweden SS031711 152 Alternating tone (two tone chime) 554 Hz 1 s 440 Hz 1 s 554 Hz 0.5 s 440 Hz 0.5 s 800 Hz 0.25 s 0.25 s 650 Hz 2 s Control of the tones Tone selection switch/dip-switch External tone selection (setting of basic tone) C1 C2 C1+C2 Basic tone 1 2 3 4 5 6 no. Tone no. 1 2 88 57 ON 2 * 128 112 57 ON 2 26 100 93 ON ON 2 61 131 112 ON 9 57 11 82 ON ON 15 131 52 112 ON ON 16 109 52 56 ON ON ON 18 111 57 68 ON 22 16 109 68 ON ON 23 131 52 112 ON ON 24 131 52 131 ON ON ON 25 131 52 92 ON ON 26 2 100 93 ON ON ON 27 123 52 92 ON ON 29 35 52 61 ON ON ON 30 27 52 77 ON 31 131 52 57 ON ON 33 30 52 35 ON ON 34 35 52 93 ON ON ON 35 27 52 110 ON ON 36 146 67 57 ON ON ON 43 131 52 91 ON ON ON 45 2 57 93 ON ON ON ON 52 15 65 82 ON ON 54 46 54 131 ON ON ON 55 131 52 128 ON ON ON 56 82 35 33 ON ON ON ON 59 143 59 101 ON ON 60 131 52 125 ON ON ON ON 65 131 52 93 ON ON ON ON 66 110 52 107 ON ON ON ON ON 69 131 52 110 * factory setting Tone selection switch/dip-switch External tone selection (setting of basic tone) C1 C2 C1+C2 Basic tone 1 2 3 4 5 6 no. Tone no. ON 71 131 52 93 ON ON 77 61 52 122 ON ON 82 131 52 83 ON ON ON 83 56 2 82 ON ON 88 2 57 128 ON ON ON 90 131 52 125 ON ON ON 91 30 52 110 ON ON ON ON 92 33 52 57 ON ON 93 2 128 57 ON ON ON 97 2 63 93 ON ON ON 100 131 52 125 ON ON ON ON 101 98 102 65 ON ON ON 103 131 65 147 ON ON ON ON 104 103 65 101 ON ON ON ON 109 16 52 22 ON ON ON ON ON 110 131 61 91 ON ON 112 2 57 128 ON ON ON 113 52 123 104 ON ON ON 115 117 116 44 ON ON ON ON 116 117 93 125 ON ON ON 117 93 116 125 ON ON ON ON 123 27 52 77 ON ON ON ON 124 53 83 2 ON ON ON ON ON 130 2 107 67 ON ON ON 131 2 112 57 ON ON ON ON 135 16 56 109 ON ON ON ON 142 2 54 88 ON ON ON ON ON 143 59 93 33 ON ON ON ON 144 110 61 2 ON ON ON ON ON 146 31 67 57 ON ON ON ON ON 148 131 52 92 ON ON ON ON ON ON 152 110 61 13 Visual-audible signaling devices ACCESSORIES PATROL AND PYRA Ordering details Article numbers PA X 1-05 PA X 5-05 PA 10 X / PA 20 X PY X-MA Enclosure fitting For connection (daisy-chaining) of several sounders of the PATROL series 283 00 00 0 003 Surface gasket Tamper-proof sealing (pack of 4) Sealing of the sounder installation surface when, e.g. cable entry is executed from the back. Anti-tamper sealing for fasteners of the PATROL or PYRA devices after installation in order to prevent manipulation of the devices. 283 00 00 0 004 283 00 00 0 005 283 00 00 0 006 281 11 50 0 000 283 00 00 0 002 Further technical information can be found on our website at www.pfannenberg.com 165

COMBINED VISUAL-AUDIBLE SIGNALING DEVICES CONNECTION DIAGRAMS SON 4 external tone control operating voltage connection tone selection switch Settings of DIP switches 6 8: switch 6: not used switch 7 to ON: medium volume switch 8 to ON: maximum volume switches 7 and 8 to ON: standard volume S2 stage 2 S3 stage 3 SON 4L AC SON 4L DC S2 stage 2 S3 stage 3 S2 stage 2 S3 stage 3 Tone S3 - stage 3 S2 - stage 2 Tone selection: to select a tone, place the jumper in the positions shown above S3 - stage 3 S2 - stage 2 PY X-MA-05 / PY X-MA-10 tone selection switch S1, S2 closed during common operation of sounder and fl ashing light volume control operating voltage connection for light operating voltage connection for sounder 166 www.pfannenberg.com

DSF 5 / DSF 10 sounder AC DSF 5 / DSF 10 light DC flashing light for supplying power to additional devices continuous light 12 / 24 / 48 V DC 24 V AC 115/230 V AC operating voltage connection for supplying power to additional sounders; max. 10 of type DS 10 or max. 15 of type DS 5 PA X 1-05 / PA X 5-05 / PA X 10-05 / PA X 10-10 / PA X 20-10 / PA X 20-15 Separated connection of flashing light and sounder connector from the flashing light circuit board X3 -L +N -L X2 L N + S3 -+ (by-passing the reverse polarity diode) DC + operating voltage connection for flashing light L N + L N + (selection of the polarity of the control voltage for C1 and C2) S2 - S3 + tone selection switch factory setting Further technical information can be found on our website at www.pfannenberg.com AC with reverse polarity protection (factory setting) tone selection switch open -L S2 (by-passing the reverse polarity protection diode) S1 closed C1 +N PA X 10-05 / PA X 10-10 / PA X 20-10 / PA X 20-15 volume control Note: In order to conform to EN54-3, the volume control must be set to the maximum position S1 C1 -L operating voltage connection for sounder PA X 1-05 / PA X 5-05 S2 C2 -L AC: sounder and flashing light operating voltage connection C2 +N +N DC: C1 -L AC: C2 +N DC: C2 C1 +N AC: X2 X3 X4 X4 Connection diagrams connector from the flashing light circuit board DC: Common connection of flashing lights and sounders (delivery condition) without reverse polarity protection + - volume control Note: In order to conform to EN54-3, the volume control must be set to the maximum position S3 S1 (selection of the polarity of the control voltage for C1 and C2) factory setting + 167

SIGNAL TOWERS 168 www.pfannenberg.com

SIGNAL TOWERS AN IMPORTANT COMPONENT OF YOUR PROCESS RELIABILITY! BENEFIT FROM THE VERSATILE USES OF OUR RANGE OF SIGNAL TOWERS Just imagine a simple traffi c light, equipped with the shining colours red, yellow and green. Everybody knows what the colours mean; a particular situation in the road traffi c process. This traffi c light could theoretically also be equipped with acoustic assistance. If the light is red, a tone is heard that means stop ; if it s yellow, attention: get ready to go is signalled acoustically etc. Signal Towers You can assemble Pfannenberg signal lights with their stable stainless steel tubular stands individually according to this example and exactly as your machine pool demands it. One look at the signal tower and the observer knows and hears instantly which process state the machine in question is in. For example, start, warm-up phase, optimum operating temperature, overheating etc. Signal technology can be as intelligent as that. Our signal lights can be supplied as continuous, LED, blinking or fl ashing lights for safety-relevant applications and carry UL and GOST approvals in addition to the obligatory CE marking. Further technical information can be found on our website at www.pfannenberg.com 169

SIGNAL TOWERS SIGNAL TOWER Ø 54 MM BR 50 IP 54 IP 65 UL + 50 C - 25 C modular design with sturdy housing for all indoor and outdoor applications in tough conditions wherever machine status needs to be displayed and warning signals given high protection system IP 54 (optionally IP 65) fl exible building kit system guarantees easy handling up to 5 modules with 6 lens colours can be combined as desired by simply plugging together, even retrospectively mechanical and electronic components are uncoupled, resulting in a more stable structure that is less sensitive to vibration many different variations are possible, can be fi xed by means of tubular stand, tube or direct mounting made of environmentally-friendly materials as per DIN ISO 14000 monitored module for greater safety; the light bulb has two separate LED strands. If one strand fails, the alarm contact is activated and the second strand continues to light Protection system Option Operating temperature Technical data BR 50 (standard modules) Modules continuous light blinking light 1.5 Hz fl ashing light sounder Colours Segment stages (total) clear, yellow, amber, red, green, blue max. 5 (order and colour can be selected individually) Dispersion 360 Light source 1 bulb BA15d LED bulb BA15d LED Rated power Flash energy Flash frequency Sound pressure level per stage 7 W depending on 7 W depending on per stage if 5 stages 5 W voltage 5 W voltage 230 V / 115 V AC 0.6 J 24 V AC/DC 24 V: 1 J approx. 1 Hz Alarm tones 7 Nominal current consumption (50/60 Hz) Nominal current consumption Operating temperature 85 db (A) 230 V AC 35 ma 15 ma 35 ma 10.5 ma 15 ma 115 V AC 64 ma 15 ma 20 ma 15 ma operating range - 15%... + 10% - 10%... + 15% - 15%... + 10% 24 V DC: 300 ma DC: 30 ma DC: 250 ma DC: 30 ma AC/DC: 100 ma 12 ma operating range - 15%... + 20% 10 V 30 V AC: 10 V 27 V DC: 10 V 35 V - 15%... + 20% with bulb - 25 C... + 50 C - 25 C... + 50 C - 10 C... + 45 C with LED - 30 C... + 60 C Relative humidity 90% Protection system according to EN 60529 IP 54 IP 43 Duty cycle 100% Service life of light source approx. 1,500 h approx. 50,000 h approx. 1,500 h approx. 50,000 h light emission still 70% after 8,000,000 fl ashes base acrylonitrile butadiene styrene (ABS) Material lens tube polycarbonate (PC) stainless steel Tube thread 30 mm, M16 x 1,5 Mounting vertical or horizontal Mounting information the sounder module or the monitored module is always the uppermost module; a maximum of 1 monitored module may be used per signal tower Weight module 80 g 90 g 90 g 230 g base mounting stand: approx. 220 g / tube mounting: approx. 200 g / direct mounting: approx. 180 g 1 please order light source separately 170 www.pfannenberg.com

Technical data monitored continuous light module BR 50 AS-i Bus slave Modules AS-i AS-i-AB Module types Colours monitored continuous light yellow, red LED module, sounder module, continuous light module, blinking light module Segment stages (total) max. 3 max. 4 max. 3 Dispersion 360 Light source 2 x 8 LED (not exchangeable) AS-i profile S-8.F.E S-8.A.E AS-i specification AS-i 3.0 / EN 50295 Programming DC-Jack, Ø 1.3 mm max. slave/master 31 62 Alarm output Rated power max. 230 V / 80 ma, R ONmax = 35 Ω (closed at error-free operation) 24 V DC Nominal current consumption approx. 35 ma < 0.25 A Operating range - 15%... + 20% 26.5 V 31.6 V Operating temperature - 30 C... + 60 C Relative humidity 90% Protection system according to EN 60529 IP 54 Duty cycle 100% Service life of light source Material 50,000 hrs @ 24 C, 40% R.H. base acrylonitrile butadiene styrene (ABS) lens polycarbonate (PC) Mounting vertical or horizontal Mounting information the AS-i / AS-i-AB module is always used as the lowest module Weight 90 g 90 g Connection and configuration options for monitored modules Use of one monitored module per signal tower: - confi guration as top module (top module is monitored) - confi guration as bottom module (bottom module is monitored) Use of 2 monitored modules per signal tower Configuration as top module (top module is monitored) Base module + 1 Base module + 1 st stage monitored st stage not monitored, 2 nd stage monitored -/N supply voltage (-), common connection for all stages 1+/L supply voltage (+), activation of monitored module 2+/L potential-free alarm output contact 1 3+/L potential-free alarm output contact 2 4+/L n.c. 5+/L n.c. -/N supply voltage (-), common connection for all stages 1+/L supply voltage (+), activation of 1 st stage 2+/L supply voltage (+), activation of 2 nd stage (monitored) 3+/L potential-free alarm output contact 1 4+/L potential-free alarm output contact 2 5+/L n.c. Base module + 1 st /2 nd stage not monitored, 3 rd stage monitored -/N supply voltage (-), common connection for all stages 1+/L supply voltage (+), activation of 1 st stage 2+/L supply voltage (+), activation of 2 nd stage 3+/L supply voltage (+), activation of 3 rd stage (monitored) 4+/L potential-free alarm output contact 1 5+/L potential-free alarm output contact 2 Signal Towers 282 50 06 80.. BR50-LED-M 282 50 06 80.. BR50-LED-M 282 50 06 80.. BR50-LED-M 5+/L 4+/L 3+/L 2+/L 1+/L -/N e. g. BR50-CL 5+/L 4+/L 3+/L 2+/L 1+/L -/N e. g. BR50-CL e. g. BR50-CL 5+/L 4+/L 3+/L 2+/L 1+/L -/N Further technical information can be found on our website at www.pfannenberg.com 171

SIGNAL TOWERS Configuration as bottom module (bottom module is monitored) Base module + 1 Base module + 1 st stage monitored st stage monitored, 2 nd stage not monitored -/N supply voltage (-), common connection for all stages 1+/L supply voltage (+), activation of monitored module 2+/L n.c. 3+/L n.c. 4+/L potential-free alarm output contact 1 5+/L potential-free alarm output contact 2 -/N supply voltage (-), common connection for all stages 1+/L supply voltage (+), activation of 1 st stage (monitored) 2+/L supply voltage (+), activation of 2 nd stage 3+/L n.c. 4+/L potential-free alarm output contact 1 5+/L potential-free alarm output contact 2 Base module + 1 st stage monitored, 2 nd /3 rd stage not monitored -/N supply voltage (-), common connection for all stages 1+/L supply voltage (+), activation of 1 st stage (monitored) 2+/L supply voltage (+), activation of 2 nd stage 3+/L supply voltage (+), activation of 3 rd stage 4+/L potential-free alarm output contact 1 5+/L potential-free alarm output contact 2 282 50 06 80.. BR50-LED-M e. g. BR50-CL e. g. BR50-SM 5+/L 4+/L 3+/L 2+/L 1+/L -/N 282 50 06 80.. BR50-LED-M 5+/L 4+/L 3+/L 2+/L 1+/L -/N e. g. BR50-CL 282 50 06 80.. BR50-LED-M 5+/L 4+/L 3+/L 2+/L 1+/L -/N Use of 2 monitored modules per signal tower Base module + 1 st /2 nd stage monitored -/N supply voltage (-), common connection for all stages 1+/L supply voltage (+), activation of 1 st stage (monitored) 2+/L supply voltage (+), activation of 2 nd stage (monitored) 3+/L alarm output module 2 4+/L common connection alarm outputs 5+/L alarm output module 1 top module 282 50 06 80.. BR50-LED-M 3+/L 5+/L bottom module 282 50 36 80.. BR50-LED-M 4+/L fault contact module 2 5+/L 4+/L 3+/L 2+/L 1+/L -/N fault contact module 1 The alarm outputs of both levels have a shared contact! Caution: Max. 2 modules can be utilized 172 www.pfannenberg.com

Dimensions L1 tube mounting L1 mounting stand Tube length 100 78 88 Tube length 250 228 238 Tube length 400 378 388 Ø 54 L2 1-stage 107 2-stage 170 3-stage 233 63 Signal Towers 20 L1 L2 3 4-stage 296 5-stage 359 Mounting bracket 20 37 Ø 54 ± 0.2 Stand mounting gasket Ø 70 ± 0.2 Ø 20 + = 2 +0.7 Ø 4.8 ± 0.1 42 15 9 Ø 4.5 M16 x 1.5 30 17 35 5 ± 0.3 50 Bayonet connection allows fast, simple and safe mounting Base and Light module Light module Light module Light module Light module Light module AS-i Sounder end module clear yellow amber red green blue module module Further technical information can be found on our website at www.pfannenberg.com 173

SIGNAL TOWERS Configuration alternatives Sounder module Stage 5 Flashing light module Stage 4 Continuous light module with LED Stage 3 Blinking light module Stage 2 Monitored module Continuous light module AS-imodule Stage 1 Mounting variants 174 www.pfannenberg.com

Ordering details Article numbers BR 50 modules Version Rated voltage 230 V AC 115 V AC 24 V DC Base and end module BR50-BC 282 50 01 0 000 clear BR50-CL-CL 282 50 04 0 010 yellow BR50-CL-YE 282 50 04 0 030 Continuous light module amber BR50-CL-AM 282 50 04 0 040 red BR50-CL-RE 282 50 04 0 050 green BR50-CL-GR 282 50 04 0 060 blue BR50-CL-BL 282 50 04 0 070 clear BR50-BL-CL 282 50 05 1 010 282 50 05 1 610 282 50 05 8 010 yellow BR50-BL-YE 282 50 05 1 030 282 50 05 1 630 282 50 05 8 030 Blinking light module amber BR50-BL-AM 282 50 05 1 040 282 50 05 1 640 282 50 05 8 040 red BR50-BL-RE 282 50 05 1 050 282 50 05 1 650 282 50 05 8 050 green BR50-BL-GR 282 50 05 1 060 282 50 05 1 660 282 50 05 8 060 blue BR50-BL-BL 282 50 05 1 070 282 50 05 1 670 282 50 05 8 070 clear BR50-FL-CL 282 50 07 1 010 282 50 07 1 610 282 50 07 8 010 yellow BR50-FL-YE 282 50 07 1 030 282 50 07 1 630 282 50 07 8 030 Flashing light module amber BR50-FL-AM 282 50 07 1 040 282 50 07 1 640 282 50 07 8 040 red BR50-FL-RE 282 50 07 1 050 282 50 07 1 650 282 50 07 8 050 green BR50-FL-GR 282 50 07 1 060 282 50 07 1 660 282 50 07 8 060 blue BR50-FL-BL 282 50 07 1 070 282 50 07 1 670 282 50 07 8 070 LED module, monitored (top module) LED module, monitored (bottom module) yellow BR50-LED-M-YE 282 50 06 8 030 red BR50-LED-M-RE 282 50 06 8 050 yellow BR50-LED-M-YE 282 50 36 8 030 red BR50-LED-M-RE 282 50 36 8 050 Sounder module BR50-SM 282 50 08 1 000 282 50 08 1 600 282 50 08 8 000 AS-i module BR50-AS-i 282 50 14 8 300 AS-i-AB module BR50-AS-i-AB 282 50 17 8 300 Information module BR50-IM 282 50 27 0 000 Tubular stand with plinth Tube with thread and bracket (excl. seal and cable) 100 mm BR50-S100 282 50 15 0 010 250 mm BR50-S250 282 50 15 0 020 400 mm BR50-S400 282 50 15 0 040 100 mm BR50-T100 282 50 16 0 010 250 mm BR50-T250 282 50 16 0 020 400 mm BR50-T400 282 50 16 0 040 Signal Towers Light bulbs for constant light and blinking light modules must be ordered separately www.pss-pfannenberg.com Use our PSS Software Tool for easy configuration of the signal tower according to your individual requirements Options / Accessories Lamp remover Article number: 282 50 25 0 000 Wall bracket for mounting stand Article number: 282 50 20 0 000 Mounting kit for direct mounting Article number: 282 50 21 0 000 Gaskets IP 65 Article number: 282 50 22 0 000 282 50 23 0 000 Light source C US LISTED GOST See pages 180/181 for further information Further technical information can be found on our website at www.pfannenberg.com 175

SIGNAL TOWERS Ordering example Signal tower Article numbers 5-stage, IP 65 Version 230 V AC 24 V DC Sounder module BR50-SM 282 50 08 1 000 282 50 08 8 000 + Flashing light module BR50-MG 282 50 22 0 000 + BR50-FL 282 50 07 1 050 282 50 07 8 050 Continuous light module with bulb or LED Blinking light module with bulb or LED Continuous light module with bulb or LED + BR50-MG + BR50-CL + bulb or LED BA 15d + BR50-MG + BR50-BL + bulb or LED BA 15d + BR50-MG + BR50-CL + bulb or LED BA 15d + BR50-MG + BR50-BC + 282 50 22 0 000 282 50 04 0 060 282 13 00 0 004 282 13 00 0 000 282 13 00 0 018 282 13 00 0 011 282 50 22 0 000 282 50 05 1 030 282 50 05 8 030 282 13 00 0 004 282 13 00 0 000 282 13 00 0 030 282 13 00 0 007 282 50 22 0 000 282 50 04 0 010 282 13 00 0 004 282 13 00 0 000 282 13 00 0 014 282 13 00 0 006 282 50 22 0 000 282 50 01 0 000 Mounting stand (100 mm) and seal BR50-TG 282 50 23 0 000 BR50-S100 282 50 15 0 010 176 www.pfannenberg.com

SIGNAL TOWER Ø 35 MM BR 35 modular design with six different colour elements and four mounting methods offers endless combination possibilities high protection system the light is amplifi ed by the internal prisms of the impact-proof, heat-resistant and dustproof polycarbonate lens and can be easily identifi ed from all sides appealing design with a diameter of just 35 mm the BR 35 signal tower is the attractive icing on the cake for machine and production lines for use in electronic production, in laboratories, in medical technology and in all other indoor applications the technically and economically optimum solution for every application registered design no. 9706583.8, utility patent no. 29716867.3 IP 54 Protection system + 55 C - 35 C LED + 45 C - 35 C Filament lamp Electrical data BR 35 Rated voltage 230 V AC 115 V AC 24 V DC 12 V DC Rated frequency 50 Hz / 60 Hz 50 Hz / 60 Hz Operating range - 15% / + 10% - 15% / + 10% - 15% / + 20% - 15% / + 20% Capacity of light source 3 W 3 W 4 W 4 W Mechanical data BR 35 Light source AC BA9s, 3 W (previously installed) DC BA9s, max. 4 W (previously installed) Number of modules max. 4 Lens colours clear, yellow, amber, red, green, blue Sound pressure level, sounder module 75 db (A) Operating temperature LED - 35 C... + 55 C fi lament lamp - 35 C... + 45 C Storage temperature - 45 C... + 70 C Relative humidity 90% Protection system according to EN 60529 IP 54 Duty cycle 100% Service life of light source approx. 1,000 hrs housing acrylonitrile butadiene styrene (ABS) Material lens polycarbonate (PC) tube stainless steel Type of connection cable length 0.5 m tube mounting; 0.65 panel mounting Terminal cross-section single wire: 1.5 mm 2, fi ne wire: 0.14 1.5 mm 2 Mounting information just one screw is suffi cient for exchanging beacon fi lters or light source Mounting methods mounting stand, plinth mounting, tube mounting, panel mounting (see drawings on page 178) Signal Towers www.pss-pfannenberg.com Use our PSS Software Tool for easy configuration of the signal tower according to your individual requirements Further technical information can be found on our website at www.pfannenberg.com 177

SIGNAL TOWERS Dimensions Stand mounting Plinth mounting Tube mounting Panel mounting L4 seal mounting surface L1 35 L2 L3 35 intermediate pieces; standard 3 pieces 48 147 20 35 M12 x 1 L = 500 60 60 60 M12 x 1 20 11 M20 x 1.5 L = 650 164 Panel cut-out 16.5 45 Ø 4.5 Ø 4.5 Ø 13 20.5 +2-0 47.5 47.5 L = 500 L1 L2 L3 L4 1-stage 228 228 210 91 2-stage 276 276 258 142 3-stage 324 324 306 190 4-stage 372 372 354 238 5-stage 420 420 402 286 Connection diagrams Stand mounting Plinth mounting Tube mounting / Panel mounting 4 3 2 0V -/N +/L 1 Wire no. Light segment 1 1 2 2 3 3 4 4 N -/N 178 www.pfannenberg.com

Ordering details Article numbers BR 35 mounting stand Version Rated voltage 230 V AC 24 V DC 1-stage BR 35-1-S 220 80 10 1 000 220 80 80 1 000 2-stage BR 35-2-S 220 80 10 2 000 220 80 80 2 000 3-stage BR 35-3-S 220 80 10 3 000 220 80 80 3 000 4-stage BR 35-4-S 220 80 10 4 000 220 80 80 4 000 3-stage with fixed colour order: top: red, middle: yellow, bottom: green Article numbers 220 80 10 0 000 220 80 80 0 000 BR 35 plinth mounting Version Rated voltage 230 V AC 24 V DC 1-stage BR 35-1-P 220 81 10 1 000 220 81 80 1 000 2-stage BR 35-2-P 220 81 10 2 000 220 81 80 2 000 3-stage BR 35-3-P 220 81 10 3 000 220 81 80 3 000 4-stage BR 35-4-P 220 81 10 4 000 220 81 80 4 000 Article numbers BR 35 tube mounting Version Rated voltage 230 V AC 24 V DC 1-stage BR 35-1-T 220 82 10 1 000 220 82 80 1 000 2-stage BR 35-2-T 220 82 10 2 000 220 82 80 2 000 3-stage BR 35-3-T 220 82 10 3 000 220 82 80 3 000 4-stage BR 35-4-T 220 82 10 4 000 220 82 80 4 000 Article numbers BR 35 panel mounting Version Rated voltage 230 V AC 24 V DC 1-stage BR 35-1-PM 220 83 10 1 000 220 83 80 1 000 2-stage BR 35-2-PM 220 83 10 2 000 220 83 80 2 000 3-stage BR 35-3-PM 220 83 10 3 000 220 83 80 3 000 4-stage BR 35-4-PM 220 83 10 4 000 220 83 80 4 000 Article numbers for other voltages on request Options / Accessories Mounting bracket Article number: 282 35 20 0 020 for standor plinth mounting (plastic) Mounting bracket See page 181 for further information Article number: 282 35 20 0 010 for tube mounting (metal) Assembly kit sounder module Article number: 282 35 80 8 000 Short foot plinth-mounted device with short foot Light source C US LISTED GOST Signal Towers Ordering examples Stand mounting Plinth mounting Tube mounting Panel mounting A A A A B B B B C C C C D D D D 3-stage BR 35 with mounting stand 24 V DC, colour order: A = red B = yellow C = green Article number: 220 80 80 3 000 3-stage BR 35 with plinth mounting 230 V AC, colour order: A = red B = yellow C = green Article number: 220 81 10 3 000 3-stage BR 35 with tube mounting 24 V DC, colour order: A = yellow B = clear C = green Article number: 220 82 80 3 000 1-stage BR 35 for panel mounting 230 V AC, colour order: A = red Article number: 220 83 10 1 000 Please indicate color sequence (A/B/C/D) in your order as depicted above. Further technical information can be found on our website at www.pfannenberg.com 179

SIGNAL TOWERS ACCESSORIES FOR BR 50 MULTI-LED BA15D FILAMENT LAMPS Energy and cost-saving high output SMD LEDs replace fi lament lamps extremely long service life (> 50,000 hrs) low power consumption (e.g. 30 ma at 24 V) shock/vibration-resistant same brightness for all voltages resistant to environmental infl uences option plus = extra bright Ordering details Article numbers LED BA15d 22 3 Ø 18 Version Rated voltage 230 V AC 1 115 V AC 1 24 V AC/DC white standard plus 282 13 00 0 013 282 13 00 0 021 white standard 282 13 00 0 014 282 13 00 0 022 282 13 00 0 006 yellow standard plus 282 13 00 0 007 yellow standard 282 13 00 0 015 282 13 00 0 023 red standard plus 282 13 00 0 009 45 + 0.3 SW10 red standard 282 13 00 0 016 282 13 00 0 024 green standard plus 282 13 00 0 017 282 13 00 0 025 green standard 282 13 00 0 018 282 13 00 0 026 282 13 00 0 011 blue standard plus 282 13 00 0 019 282 13 00 0 027 blue standard 282 13 00 0 020 282 13 00 0 028 282 13 00 0 012 Article numbers Filament lamps BA15d BR50-L 7 W 282 13 00 0 004 282 13 00 0 002 282 13 00 0 000 BR50-L 5 W 282 13 00 0 005 282 13 00 0 003 282 13 00 0 001 1 not for flashing light module BR 50-BL, article numbers upon request LAMP REMOVER Lamp remover for simple bulb replacement. Ordering details Article numbers Lamp remover BR50-LS 282 50 25 0 000 DIRECT MOUNTING SET Gasket and mounting materials for direct mounting. Ordering details Ø 36 Ø 4.5 Ø 20 + = 2 +0.7 Ø 44 Article number Direct mounting set BR50-BG 282 50 21 0 000 OPTION IP 65 Gaskets for higher protection system IP 65. Ordering details Article numbers IP 65 gaskets Module gasket BR50-MG (1 x per light module plus 1 x base module) 282 50 22 0 000 Tube gasket BR50-TG (for tubular stand or tube mounting only) 282 50 23 0 000 180 www.pfannenberg.com

WALL BRACKET WITH HOOD Plastic wall holder for mounting the BR 50 on a tubular stand. Dimensions BR 50-W 110 84.6 73 59.3 42.5 40 65 60 Ø 4.5 75 50 27 62.4 16 23 61.3 13.7 12.6 Ø 55 9.5 61.4 86.7 4 x Ø 4.6 Ordering details Article number BR50-W Plastic wall bracket with hood 282 50 20 0 000 ACCESSORIES FOR BR 35 LIGHT SOURCE Filament lamps and LEDs for signal towers from the BR 35 series. Ordering details Article numbers LED Colour Rated voltage 24 V AC/DC white 286 13 00 0 000 yellow 286 13 00 0 001 red 286 13 00 0 002 green 286 13 00 0 003 blue 286 13 00 0 004 Article numbers Filament lamps BA9s Rated voltage pack of 5 12 V DC 4 W 288 13 00 0 003 24 V DC 4 W 288 13 00 0 002 115 V AC 3 W 288 13 00 0 001 230 V AC 3 W 288 13 00 0 000 Accessories and light sources MOUNTING BRACKET Bracket for mounting the BR 35. Ordering details Article numbers Mounting bracket Plastic bracket for mounting on tubular stand or plinth BR35-W 282 35 20 0 020 Metal bracket for tube mounting BR35-A 282 35 20 0 010 Further technical information can be found on our website at www.pfannenberg.com 181

EX SIGNALING DEVICES 182 www.pfannenberg.com

Our Ex-series visual and acoustic signaling devices stand out with their particularly sturdy construction and insensitivity to environmental infl uences and chemicals. These are information, warning and emergency signals for safety, hazard and fi re alarm systems; for building, industrial and commercial automation; for disaster warnings and for hazardous areas. ALARM SAFETY EVEN IN EXPLOSIVE AREAS EX SIGNALING DEVICES ARE USED WHEREVER EXPLOSIVE GASES, VAPOURS AND DUSTS CAN BECOME DANGEROUS Ex Signaling devices Further technical information can be found on our website at www.pfannenberg.com 183

EX SIGNALING DEVICES SAFETY FOR MAN, MACHINE AND THE ENVIRONMENT If it s about safety, Pfannenberg is always the right choice, because the Pfannenberg brand stands for safety for man, machine and the environment. Global references speak a clear language. Ex-protected visual and acoustic signaling devices by Pfannenberg are subjected to the toughest demands every day and are in use wherever explosive atmospheres can be formed, e.g. in oil and gas drilling in the North Sea - by Shell DEA, Exxon Mobil...- or in refi neries and chemical plants - at BASF, Bayer, Degussa Regardless of whether it s about corrosion, vibration, shock or alternating climates, you are always on the safe side with Ex alarm products by Pfannenberg! Gas detection with visual and acoustic alarms: DS 10 ATEX sounder and CWB-ATEX fl ashing light Acoustic alarm in a gas-fi red power station: BExS 120 ATEX sounder The CWB-ATEX flashing light and the BExS 120 ATEX sounder signal danger here without becoming a danger themselves highly visible and highly audible 184 www.pfannenberg.com

ATEX GUARANTEES YOUR SAFETY DIRECTIVES In the Ex-Directive 94/9/EU, the European Union has provided a basis for binding uniform requirements for characteristics with regard to the protection of systems, appliances and components against explosion. With these standards, the manufacturer can assume when designing and assessing the explosion protection that he is developing explosion-protected systems, appliances and components that conform to the Ex- Directive 94/9/EU and which are then subjected to uniform binding test procedures by an appointed body of the European Union. A uniform classifi cation of explosion-endangered plants is the basis for the selection, assignment and installation of systems, appliances and components. In order to protect employees, the user is obliged by Directive 1999/92/EU to assess the explosion risk of the plant, to divide the plant into danger zones and to draw up an explosion protection document or a series of documents, which fulfi l the requirements contained in this directive, and to keep them up to date. Through directives 94/9/EU and 1999/92/EU, the prerequisites have been created for a complete unifi cation of the regulations for protection against explosion in the European Union and form a closed system, with which explosions can be effectively avoided in order to protect man, machine and environment. SELECTING SUITABLE EX ALARM PRODUCTS The selection of suitable alarm products is essentially governed by two factors, which can be distinguished as follows: a) Ex environmental requirements b) Functional requirements EX ENVIRONMENTAL REQUIREMENTS Groups and gases Explosion-protected products are catalogued with regard to their different purposes of use. The fi rst distinguishing criteria is whether usage is underground or above ground: Group I: operating equipment for underground mining with a fi redamp risk Group II: operating equipment for all other (non-group I) areas A further distinction is made in Group II according to the types of gases present in the operation environment and the temperature class. On the one hand, this describes the maximum surface temperature of the explosion-protected device and, on the other, the minimum ignition temperature of the gas or vapour. For secure protection against explosion, it must be ensured that the surface temperature of the device (e.g. the fl ashing light) is always lower than the ignition temperature of the gas. Classification of gases and vapours into temperature classes and gas groups I IIA T1 450 C Methane Acetone Ethane Ethyl acetate Benzene Acetic acid Ammonia Carbon monoxide Methane Toluene Propane Methanol T2 300 C Ethyl alcohol i-amyl acetate n-butane n-butyl alcohol T3 200 C Petrol Diesel Aviation fuel n-hexane Heating oil IIB Town gas Ethylene T4 135 C Acetyl aldehyde T5 100 C T6 85 C IIC Hydrogen Acetylene CS 2 The gases are classifi ed in groups ABC according to their fl ammability. This in turn generates different requirements for the enclosures of electrical equipment. For explosion-proof enclosures, these include the dimensions of the closure gap. The gas groups are upwardly compatible, i.e. devices that are suitable for use in group IIC can also be used in the groups IIB or IIA. The same compatibility applies to the temperature classes, according to which devices from temperature class T6 can also be used in all other temperature classes. However, devices from temperature class T4 are adequate for most applications. Technology Further technical information can be found on our website at www.pfannenberg.com 185

EX SIGNALING DEVICES ATEX GUARANTEES YOUR SAFETY ZONES AND CATEGORIES Potentially explosive areas are defi ned in section 2 of ElexV (Germany) as areas in which the atmosphere may be capable of explosion due to local and operational conditions. It has proven to be useful to divide potentially explosive areas into zones, taking into account different hazards caused by explosive atmospheres. Definition of the zones according to section 2 para. 4 ELX (96) Potentially explosive areas due to combustible gases Zone 0 Zone 1 Zone 2 Areas in which an explosive atmosphere of gases, vapours or mists exists constantly, over long periods or frequently. Areas in which an explosive atmosphere of gases, vapours or mists occasionally occurs. Potentially explosive areas due to combustible dusts Zone 20 Zone 21 Zone 22 Areas in which an explosive dust atmosphere exists constantly, over long periods or frequently. Areas in which an explosive dust atmosphere occasionally occurs. Areas in which explosive atmospheres of gases, vapours and mists normally never occur, but if they do, then only rarely and only for short time periods. Areas in which explosive dust atmospheres normally never occur, but if they do, then only rarely and only for short time periods. The Ex devices are sub-divided analogue to the Ex zones into the following device categories Device classification according to groups and categories: Group I Group II Category M Category 1 Category 2 Category 3 G D G D G D 1 2 (gas) Zone 0 (dust) Zone 20 (gas) Zone 1 (dust) Zone 21 (gas) Zone 2 (dust) Zone 22 186 www.pfannenberg.com

ATEX GUARANTEES YOUR SAFETY TYPES OF PROTECTION SYSTEMS The European standards describe eight different explosion protection methods that can be applied in order to make electrical equipment suitable for use in the various ex zones. The different types of protection vary widely with regard to the degree of complexity and some of them are not usable with mobile equipment, for example. The type of ignition protection is selected with the greatest of care for Pfannenberg devices in order to guarantee the best possible cost-benefi t ratio. Pfannenberg uses the following protection systems for its alarm equipment: Flame proof enclosure d In the case of pressure-resistant encapsulation, the actual operating equipment is built into a pressure-resistant housing. In the event of an explosion inside, the housing prevents an ignition breakthrough into the surrounding area. The explosion is therefore restricted to the interior of the device. On account of the necessary wall thickness, devices in this protection system are of a very sturdy construction and thus also often very well suited for adverse environmental conditions. Enhanced safety e This type of enhanced protection is usable with only a few types of equipment/components (e.g. terminals). This type of protection is conveniently often combined with pressureresistant encapsulation. In alarm products, this means that all essential components are housed in the pressure-resistant housing and only the connection terminals are accessible in the increased safety housing. For this reason Pfannenberg also offers most devices with an e connection box in order to enable simple and safe electrical connections to be made. The sensitive electronic components are therefore protected against accidental damage during mounting. Intrinsically safety i In the ignition protection type i, the current and voltage of all energy storage devices as well as the complete device are limited to the extent that no ignition sparks and no excessively hot surfaces can be generated. An explosive atmosphere can develop, but it will not be ignited. Technology Further technical information can be found on our website at www.pfannenberg.com 187

EX SIGNALING DEVICES ATEX - DESIGNATION OF ELECTRICAL EQUIPMENT FOR POTENTIALLY EXPLOSIVE ENVIRONMENTS! Conditions in potentially explosive areas Combustible substances gases, vapours Device category and Equiment protection level (EPL) according to EU directive 94/9/EG (ATEX) Temporary behaviour of the combustible substance in the Ex area continuously, for long periods or frequently Zone 0 occur occasionally Zone 1 rarely and for a short period Zone 2 according to IEC / CENELEC Device group Device category EPL adequate safety mining with a fi redamp risk I M1 Ma rare errors I M2 Mb till disconnection the unit areas due to combustible gases II 1G Ga Zone 0 rare errors II 2G Gb Zone 1 predictable failures II 3G Gc Zone 2 during normal operation areas due to combustible dusts II 1D Da Zone 20 rare errors II 2D Db Zone 21 predictable failures II 3D Dc Zone 22 during normal operation G related electrical equipment - installation in safe area Classification of the potentially explosive areas Required marking of the operating equipment to be used according to CENELEC CENELEC/IEC US NEC 505 US NEC 500 Device group Device category Class I Zone 0 Class I Zone 1 Class I Zone 2 dusts continuously, for long periods or frequently Zone 20 Class I Division 1 Class I Division 2 Class II Division 1 II 1G Ga Equiment protection level (EPL) according to EN 60079-0 II 2G or 1G Gb or Ga II 3G or 2G or 1G II 1D Da Gc or Gb or Ga occur occasionally Zone 21 II 2D or 1D Db or Da rarely and for a short period Zone 22 Class II Division 2 II 3D or 2D or 1D methane, dust operation where there is a risk of explosion I M1 Ma Dc or Db or Da disconnection where there is a risk of explosion I M2 or M1 Mb or Ma Inspection authority Notified body Country Id-Number TÜV Nord Cert Germany 0044 PTB Germany 0102 DEKRA EXAM Germany 0158 FSA Germany 0588 BAM Germany 0589 IBExU Germany 0637 INERIS France 0080 LCIE France 0081 DEKRA B.V. Netherlands 0344 SP Sweden 0402 LOM Spain 0163 BASEEFA UK 1180 SIRA UK 0518 ATEX NEC 500 Class I Division 1 NEC 505 Class I Zone 1 IEC CENELEC CE 0158 II 2G 188 www.pfannenberg.com

Temperature classes and highest permissible surface temperatures of the equipment Highest permissible surface temperature USA (NEC 500) Usability of the equipment T6 T5 T4 T3 T2 T1 Temperature classes according to CENELEC/IEC NEC 505 * typical ignitable gas Max. surface temperature of the equipment T1 450 C > 450 C Ignition temperature of the combustible substances 450 C T1 T2 300 C > 300 C < 450 C 300 C T2 T3 200 C > 200 C < 300 C 280 C T2A T4 135 C > 135 C < 200 C 260 C T2B T5 100 C > 100 C < 135 C 230 C T2C T6 85 C > 85 C < 100 C 215 C T2D 200 C 180 C T3 T3A Classification of gases and vapours into explosion groups and temperature classes Classification into temperature classes / gas groups (extract) 165 C T3B T1 T2 T3 T4 T5 T6 160 C T3C I Methane 135 C T4 IIA Acetone Ethyl alcohol Petrols Acetaldehyde Acetic acid n-butane Heating oil Ethyl ether 120 C 100 C T4A T5 Ammonia Propane * n-butyl alcohol Diesel 85 C T6 IIB Town gas Ethylene * IIC Hydrogen * Acetylene * Carbon bisulphide Protective systems Protective system Marking Standard Alternate Protection principle Zone Standard Applications general requirements IEC 60079-0 EN 60079-0 all applications fl ame proof enclosure Ex d Ex db transmission of an explosion to the outside is excluded 1 IEC 60079-1 EN 60079-1 switchgear, controllers, motors, command and alarm devices, power electronics increased safety Ex e Ex eb intrinsically safety pressurized encapsulation Group A, B, C, D Ex ia Ex ib Ex ic Ex px Ex py Ex pz Ex ma Ex mb Ex mc Ex ia Ex ib Ex ic Ex pxb Ex pyb Ex pzc Ex ma Ex mb Ex mc oil immersion Ex o Ex ob powder fi lling Ex q Ex qb type n protection Ex na 1 Ex nc 1 Ex nr 1 Ex nac Ex ncc Ex nrc 1 na = non-sparking, nc = sparking equipment (suitable protection), nr = vapour-proof enclosure avoidance of sparks and high temperatures limitation of the energy of sparks and temperatures Ex atmosphere is kept away from the source of ignition Ex atmosphere is kept away from the source of ignition Ex atmosphere is kept away from the source of ignition transmission of an explosion to the outside is excluded various protection principles for Zone 2 AEx d IIC T6 Ex de IIC T6 Gb Ex de IIC T6 Gb PTB 01 ATEX 1234 X T6 1 0 1 2 1 1 2 0 1 2 1 1 2 IEC 60079-7 EN 60079-7 IEC 60079-11 EN 60079-11 IEC 60079-2 EN 60079-2 IEC 60079-18 EN 60079-18 IEC 60079-6 EN 60079-6 IEC 60079-5 EN 60079-5 IEC 60079-15 EN 60079-15 Additional conditions Conditions Equipment usable without restriction Observe special conditions for use junction and terminal boxes, enclosures, motors, beacons, terminals measurement, control and regulating equipment, sensors, actuators, instrumentation power and control cabinets, motors, measurement and analysis devices, computers relay and motor coils, circuitry, solenoid valves, connecting systems transformers, relays, start-up controllers, switching devices transformers, relays, capacitors all applications for Zone 2 When using the alternate symbols the EPL can be omitted. Ex component with partial certifi cation, not capable of operation alone; CE conformity is only certifi ed after installation in complete equipment X Marking Technology Further technical information can be found on our website at www.pfannenberg.com 189

EX SIGNALING DEVICES ALL EX SIGNALING DEVICES AT A GLANCE Type Suitable for use in zones Maximum covering distance as per EN 54-23 in metres (m) 1 Light Protection intensity / system Sound pressure level Approvals / Standards GL GOST UL 0 1 2 20 21 22 5 25 50 100 125 VdS VISUAL SIGNALING DEVICES EN 54-3 IEC Page Quadro F12-3G/3D 7.5 J IP 66 IK 08 192 Quadro-LED Flex-3G/3D 9 cd IP 66 IK 08 194 BR 50-LED 3G/3D IP 65 196 CWB-ATEX 5 J IP 66 198 BExBG 15 15 J BExBG 10 BExBG 05 10 J 5 J IP 66 IP 67 200 BExBG L1 9 cd 202 IS-mB1 6 cd IP 65 204 AUDIBLE SIGNALING DEVICES SOUNDERS DS 10 3G/3D DS 5 3G/3D 110 db (A) 105 db (A) IP 66 IP 67 206 2 BExS 120 d/e 117 db (A) 2 BExDS 120 d/e IP 66 IP 67 2 BExS 110 d/e 110 db (A) 2 BExDS 110 d/e 2 208 2 210 IS-A105N 105 db (A) IP 66 212 IS-mA1 100 db (A) IP 65 214 available in preparation 2 only d version 190 www.pfannenberg.com

Type Suitable for use in zones Maximum covering distance for a 65 db ambient noise level in metres (m) 1 Sound pressure level / Light intensity Protection system Approvals / Standards GL GOST UL 0 1 2 20 21 22 5 25 50 100 125 MED VdS AUDIBLE SIGNALING DEVICES LOUDSPEAKERS EN 54-3 IEC Page BExL 25 d/e BExL 15 d/e 117 db (A) 113 db (A) IP 66 IP 67 216 COMBINED VISUAL-AUDIBLE SIGNALING DEVICES BExCS 110-05D BExDCS 110-05D 110 db (A) 5 J IP 67 218 BExCL 15-05D 113 db (A) 5 J 220 IS-mC1 100 db (A) / 6 cd IP 65 222 ACCESSORIES Zener barriers 224 1 The specifi cation for the alarm signal reception range assumes an existing ambient noise level of 65 db (A). In accordance with applicable regulations, the calculated alarm range for the sound level 65 db (A) was given + 10 db (A) = 75 db (A). available in preparation Note: Using sounders with a sound pressure level of 120 db (A) can lead to hearing damage. People must not be permitted to stay in the near vicinity of the sounder. All specifi ed sound pressure levels are based on a measurement distance of 1 m, provided that nothing different is specifi ed. Ex Signaling devices Further information can be found on the Internet: www.pfannenberg.com www.pfannenberg-spareparts.com Keep up to date. Subscribe to our newsletter now: newsletter.pfannenberg.com Further technical information can be found on our website at www.pfannenberg.com 191

EX SIGNALING DEVICES FLASHING LIGHT 7.5 J Quadro F12-3G/3D ATEX The Quadro F12 3G/3D fl ashing light is designed for tough demands under industrial conditions and is usable as a visual alarm. The fl ashing light, which is suitable for use both indoors and out, generates bright light impulses with a high attention-drawing effect. for use in potentially explosive areas in Zone 2 as per EN 60079-10 and Zone 22 as per EN 61241-10 the requirements of the EN 60079-0, EN 60079-15, EN 61241-0, EN 61241-0 (2007) and EN 61241-1 (2005) standards are fulfi lled usable for gases in the temperature classes T1, T2, T3 and T4, as well as for non-conductive dusts, provided that the surface temperature of the equipment does not exceed + 105 C r = 15 m IP 66 IK 08 + 45 C - 20 C 10 Years Covering distance as per EN 54 Protection system Impact-proof housing Operating temperature Warranty Electrical data Quadro F12-3G/3D ATEX Rated voltage 230 V AC 115 V AC 24 V DC Rated frequency 50 / 60 Hz 50 / 60 Hz Operating range 195 253 V 95 127 V 18 30 V Nominal current consumption 90 ma 140 ma 360 ma Initial current limited to < 7 A / 150 µs < 7 A / 150 µs < 5 A / 2 ms Mechanical data Quadro F12-3G/3D ATEX Explosion protection II 3G Ex nr IIC T4-20 C Ta + 45 C II 3D Ex td A22 IP66 T105 C - 20 C Ta + 45 C Category (area of use) 3G (Zone 2) 3D (Zone 22) Conformity to standards Guideline 94/9/EG (ATEX 100a) Testing body Special conditions Flash rate Flash energy Pfannenberg X: according to the requirements of prdin EN 60 079-0, DIN EN 61241-0 (2007) and DIN EN 61241-1 (2005), the equipment is suitable for applications with a low degree of mechanical danger. It must therefore be ensured that the light is mounted with suffi cient protection against impacts. A protective cage is not mandatory. 0.83 Hz = 50 fl ashes/min. Light intensity (DIN 5037) clear lens 84 cd Lens colours 7.5 J clear, white, yellow, amber, red, green, blue Operating temperature - 20 C... + 45 C Storage temperature - 40 C... + 70 C Relative humidity 100% Protection system according to EN 60529 IP 66; mounting arbitrary Impact resistance as per EN 50102 IK 08 Protection class Duty cycle 100% Service life of the flash tube light emission still 70% after 8,000,000 fl ashes Material lens II polycarbonate (PC) housing polycarbonate (PC), RAL 7035 (optionally RAL 3000) Connecting terminals cage clamp terminal 0.08 2.5 mm 2 Cable entry Weight 2 x M20 sideways (1 x blanking plug, 1 x cable connection) 600 g 192 www.pfannenberg.com

Dimensions mounting holes Ø 4.5 113 25 113 130 80 mounting screw e.g. 4 x M4 x 20 130 blanking plug M20 x 1.5 cable connection M20 x 1.5 Ordering details Article numbers Quadro F12-3G/3D ATEX Lens colour Rated voltage 230 V AC 24 V DC clear 210 41 10 1 008 210 41 80 1 008 yellow 210 41 10 3 008 210 41 80 3 008 amber 210 41 10 4 008 210 41 80 4 008 red 210 41 10 5 008 210 41 80 5 008 Article numbers for other colours and voltages on request Options / Accessories GOST Manufacturer s declaration We hereby declare that the explosion-protected means of alarm with the type designation Quadro F12 3G/3D has been developed and manufactured in accordance with the requirements as per EN 50014. This declaration is based on compliance with the following regulations and standards: DIN EN 60079-0 Electrical equipment for areas at risk of gas explosions Part 0: General requirements DIN EN 60079-15 Electrical equipment for areas at risk of explosions Part 15: type of protection type n DIN EN 61241-0 Electrical equipment for use in areas with combustible dust General requirements DIN EN 61241-1 Electrical equipment for use in areas with combustible dust protection by enclosure td DIN EN 60598-1 Lights Part 1: General requirements and tests DIN EN 60947-1 Low-voltage switchgear Part 1: General specifi cations DIN EN 60529 Types of protection by enclosure (IP code) DIN EN 50102 Types of protection by enclosure for electrical equipment against external mechanical stresses (IK code) DIN EN 61000-6-2 Electromagnetic compatibility (EMC) Part 6-2: Generic standards, noise immunity for industrial areas DIN EN 61000-6-3 Electromagnetic compatibility (EMC) Part 6-3: Generic standards, interference emission for residential areas, business and commercial areas as well as small companies DIN EN 981 Machine safety - System of acoustic and visual alarm signals and information signals ISO 11429 System of acoustic and visual alarm signals and information signals UVV-BGV A3(VBG4) Electrical plants and equipment GSGV German Appliance Safety Act The Quadro F12 3G/3D flashing lights are approved for use in potentially explosive areas in Zones 2 and 22 as per 94/9/EU. Visual Ex signaling devices Further technical information can be found on our website at www.pfannenberg.com 193

EX SIGNALING DEVICES LED MULTI-FUNCTION LIGHT Quadro-LED Flex-3G/3D designed for tough requirements under industrial conditions suitable for indoor and outdoor use suitable for use in potentially explosive areas in Zones 2 and 22 extremely insensitive to shock and vibration maintenance-free service life exceeding 50,000 hrs internally and externally selectable operating mode as standard; one device for 4 different alarms: continuous light blinking light fl ashing light rotating light (non-wearing) 24 V AC/DC devices as standard with soft-start module can be operated directly via 24 V transistor PLC output, no additional relay control necessary inexpensive and fl exible; wide range power supplies as standard r = 5 m IP 66 IK 08 + 55 C - 20 C 10 Years Covering distance as per EN 54 Protection system Impact-proof housing Operating temperature Warranty Electrical data Quadro-LED Flex 3G/3D ATEX Rated voltage 115 V / 230 V AC 24 V AC/DC Rated frequency 50 / 60 Hz 50 / 60 Hz Operating range Current consumption in continuous light mode AC 95 253 V 15 40 V DC 10 60 V 60 ma 250 ma Mechanical data Quadro-LED Flex 3G/3D ATEX II3G Ex nr II T5 X - 20 C Ta + 55 C Explosion protection II3G Ex nr II T6 X - 20 C Ta + 50 C II3D IP66 T 85 C X - 20 C Ta + 55 C Category (area of use) 3G (Zone 2), 3D (Zone 22) Conformity to standards Guideline 94/9/EG (ATEX 100a) Testing body Pfannenberg X: according to the requirements of prdin EN 60 079-0, DIN EN 61241-0 (2007) and DIN EN 61241-1 (2005), Special conditions the equipment is suitable for applications with a low degree of mechanical danger. It must therefore be ensured that the light is mounted with suffi cient protection against impacts. A protective cage is not mandatory. Operating mode (internally and externally selectable) continuous light blinking light fl ashing light rotating all-round light Light alternation frequency 1.5 Hz 1 Hz 2.5 Hz Light source 8 x 2 LEDs (3 chip version) Light intensity (DIN 5037) clear lens 9 cd Lens colours clear, white, yellow, amber, red, green, blue Operating temperature - 20 C... + 50 C (T6) / - 20 C... + 55 C (T5) Storage temperature - 40 C... + 70 C Relative humidity 100% Protection system according to EN 60529 IP 66; mounting arbitrary Impact resistance as per EN 50102 IK 08 Protection class II Duty cycle 100% Service life of light source > 50,000 hrs Material lens polycarbonate (PC) housing polycarbonate (PC), light grey RAL 7035 Connecting terminals cage clamp terminal 0.08 2.5 mm 2 Cable entry Weight 2 x M20 x 1.5 (1 x blanking plug, 1 x cable connection) 500 g 194 www.pfannenberg.com

Dimensions blanking plug M20 x 1.5 130 25 113,5 80 mounting holes Ø 4.5 mounting screw e.g. M4 x 20 130 113.5 cable connection M20 x 1.5 Operating modes S1 Selection via 1 2 3 internal DIP switch OFF OFF OFF OFF OFF OFF ON all-round light 2.5 Hz OFF ON OFF continuous light OFF ON ON blinking light 1.5 Hz ON OFF OFF fl ashing light 1 Hz ON OFF ON all-round light 2.5 Hz ON ON OFF continuous light ON ON ON blinking light 1.5 Hz S1 - X1 - Selection via 1 1 2 3 4 external control (S1-2 = OFF, S1-3 = OFF) OFF -/N +/L OFF (standby) OFF -/N +/L +/L all-round light 2.5 Hz OFF -/N +/L +/L continuous light OFF -/N +/L +/L +/L blinking light 1.5 Hz ON -/N +/L fl ashing light 1 Hz ON -/N +/L +/L all-round light 2.5 Hz ON -/N +/L +/L continuous light ON -/N +/L +/L +/L blinking light 1.5 Hz Ordering details Article numbers Quadro-LED Flex 3G/3D ATEX Lens colour Rated voltage 115 V / 230 V AC 24 V AC/DC yellow 211 04 64 3 009 211 04 63 3 009 amber 211 04 64 4 009 211 04 63 4 009 red 211 04 64 5 009 211 04 63 5 009 Article numbers for other colours and voltages on request Options / Accessories GOST Manufacturer s declaration We hereby declare that the explosion-protected means of alarm with the type designation Quadro-LED Flex 3G/3D has been developed and manufactured in accordance with the requirements as per EN 60079. This declaration is based on compliance with the following regulations and standards: DIN EN 60079-0 Electrical equipment for areas at risk of gas explosions Part 0: General requirements DIN EN 60079-15 Electrical equipment for areas at risk of explosions Part 15: type of protection type n DIN EN 61241-0 Electrical equipment for use in areas with combustible dust General requirements DIN EN 61241-1 Electrical equipment for use in areas with combustible dust protection by enclosure td DIN EN 60598-1 Lights Part 1: General requirements and tests DIN EN 60947-1 Low-voltage switchgear Part 1: General specifi cations DIN EN 60529 Types of protection by enclosure (IP code) DIN EN 50102 Types of protection by enclosure for electrical equipment against external mechanical stresses (IK code) DIN EN 61000-6-2 Electromagnetic compatibility (EMC) Part 6-2: Generic standards, noise immunity for industrial areas DIN EN 61000-6-3 Electromagnetic compatibility (EMC) Part 6-3: Generic standards, interference emission for residential areas, business and commercial areas as well as small companies DIN EN 981 Machine safety - System of acoustic and visual alarm signals and information signals ISO 11429 System of acoustic and visual alarm signals and information signals UVV-BGV A3(VBG4) Electrical plants and equipment GSGV German Appliance Safety Act The Quadro-LED Flex 3G/3D multifunction lights are approved for use in potentially explosive areas in Zones 2 and 22 as per 94/9/EU. Visual Ex signaling devices Further technical information can be found on our website at www.pfannenberg.com 195

EX SIGNALING DEVICES SIGNAL TOWER BR 50-LED 3G/3D BR 50 for Ex applications in the categories 3G and 3D for zones 2 and 22. extremely long service life (> 50,000 hrs) the light is amplified by the internal prisms of the impact-proof, heat-resistant and dustproof polycarbonate lens and can be easily recognized from all sides the technically and economically optimum solution for every application IP 65 Protection system + 50 C - 20 C Operating temperature Electrical data BR 50-LED 3G/3D Version 1-stage 2-stage 3-stage Colour order red red / green yellow / green red / yellow / green 230 V AC 50/60 Hz 9 ma 16 ma 16 ma 24 ma Nominal current consumption 24 V AC 50/60 Hz 60 ma 90 ma 80 ma 130 ma 24 V DC 50 ma 80 ma 70 ma 120 ma 230 V AC 50/60 Hz 195 253 V Operating range 24 V AC 50/60 Hz 18 28 V 24 V DC 18 28 V Mechanical data BR 50-LED 3G/3D Explosion protection II 3G Ex na II T5 X - 20 C Ta + 50 C II 3D tda22 IP65 T85 C X - 20 C Ta + 50 C Category (area of use) 3G (Zone 2), 3D (Zone 22) Testing body Temperature class T Special conditions Operating mode Light source Pfannenberg T5 X: according to the requirements of prdin EN 60 079-0, DIN EN 61241-0 (2007) and DIN EN 61241-1 (2005), the equipment is suitable for applications with a low degree of mechanical danger. It must therefore be ensured that the light is mounted with suffi cient protection against impacts. A protective cage is not mandatory. continuous light Operating temperature - 20 C + 50 C Storage temperature - 40 C + 70 C Relative humidity 90% Protection system according to EN 60529 IP 65 Duty cycle 100% Service life of light source Material Mounting LED > 50,000 hrs lenspolycarbonate (PC) housingacrylonitrile butadiene styrene (ABS) connector housing polycarbonate (PC), light grey RAL 7035 arbitrary Connecting terminals cage clamp terminal 0.08 2.5 mm 2 Cable entry M20 bottom side 196 www.pfannenberg.com

Dimensions Connection diagram 80 stage 1 stage 2 stage 3 L M20 82 85 1-stage 107 2-stage 170 3-stage 233 Mounting holes H 50 mm x W 70 mm Ø 4.2 L Ordering details Article numbers BR 50-LED 3G/3D Version 230 V AC 24 V AC/DC 1-stage red 220 93 10 1 000 220 93 40 1 000 2-stage red/green 220 93 10 2 300 220 93 40 2 300 2-stage yellow/green 220 93 10 2 301 220 93 40 2 301 3-stage red/yellow/green 220 93 10 3 000 220 93 40 3 000 Options / Accessories Visual Ex signaling devices GOST Manufacturer s declaration We hereby declare that the explosion-protected means of alarm with the type designation BR 50-LED 3G/3D has been developed and manufactured in accordance with the requirements as per EN 60079-0. This declaration is based on compliance with the following regulations and standards: DIN EN 60079-15 Electrical equipment for areas at risk of explosions type of protection type n DIN EN 50281-1-1 Electrical equipment for use in areas with combustible dust The BR 50-LED 3G/3D signal towers are approved for use in potentially explosive areas in Zones 2 and 22 as per 94/9/EU. Further technical information can be found on our website at www.pfannenberg.com 197

EX SIGNALING DEVICES FLASHING LIGHT 5 J CWB-ATEX The fl ashing lights from the CWB-ATEX series are explosion-protected equipment and serve as visual alarms in potentially explosive workplaces in Zones 1, 2, 21 and 22 housing made of aluminium, therefore usable in all chemical and petrochemical plants as well as offshore plants high protection system and stable mechanical construction allow use under the toughest operating conditions various mounting brackets and a protective cage are available as accessories r = 11 m IP 66 + 50 C - 40 C Covering distance as per EN 54 Protection system Operating temperature GL approval Electrical datacwb-atex Rated voltage 230 V AC 110 127 V AC 24 42 V AC 60 80 V DC 12 48 V DC 24 V DC Rated frequency 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz Operating range ± 10% ± 10% ± 10% ± 10% ± 10% ± 10% Nominal current consumption 0.08 A 0.11 A 0.5 0.3 A 0.11 0.13 A 0.5 0.3 A 0.4 A Mechanical data CWB-ATEX Type of protection d fl ame proof enclosure for light housing e enhanced safety for terminal box II 2 G Ex d e IIC T6 Gb Explosion protection II 2 G Ex d e IIC T5 Gb II 2 D Ex tb IIIC T85 C Db IP66 (T6) II 2 D Ex tb IIIC T100 C Db IP66 (T5) Category (area of use) 2G (Zone 1) / 3G (Zone 2) 2D (Zone 21) / 3D (Zone 22) Certificate of conformity LCIE 02 ATEX 6113 Testing bodylcie Flash energy 5 J Flash rate approx. 1 Hz Lens colours clear, yellow, amber, red, green, blue Temperature class T6 T amb : - 40 C... + 40 C T5 T amb : - 40 C... + 50 C Storage temperature - 20 C... + 80 C Relative humidity 90% Protection system according to EN 60529 IP 66 (when used for design purpose) Duty cycle 100% Service life of the flash tube light emission still 70% after 8,000,000 fl ashes lenspolycarbonate (PC) Material protective cage stainless steel housing aluminium alloy yellow; plinth black screw terminals Type of connection terminal area (max.) 2 x 4 mm 2 (single wire); 2 x 2.5 mm 2 (fi ne wire) Cable entry 1 x cable gland M20 x 1.5, chrome-plated, clamping range 6 13 mm 1 x blanking plug, M20 x 1.5 Weight approx. 1.24 kg 198 www.pfannenberg.com

Dimensions Ø 82 Direct mounting to wall/floor Standard bracket thread depth 8 mm (M6) 282 Ø 70 260 M6 x 10 mm deep 32 80 35 32 Ø 7 35 91 X 91 35 50 25 7 Mounting plate Pipe clamp Mounting bracket 130 110 7 50 4 11/4 (Ø 42) 11/2 (Ø 48) 2 (Ø 60) 11/4 76 11/2 77 2 90 40 70 8.5 15 8.5 110 34 23 10 135 15 R66 Ordering details Article numbers CWB-ATEX Lens colour Rated voltage 230 V AC 110 127 V AC 60 80 V DC 24 42 V AC / 12 48 V DC yellow 310 06 10 3 000 310 06 13 3 000 310 06 58 3 000 310 06 90 3 000 amber 310 06 10 4 000 310 06 13 4 000 310 06 58 4 000 310 06 90 4 000 red 310 06 10 5 000 310 06 13 5 000 310 06 58 5 000 310 06 90 5 000 Article numbers for other colours on request Options / Accessories Pipe clamps Stainless steel Article number: R1 1/4 : 38108101000 R1 1/2 : 38108101200 R2 : 38108102000 Mounting bracket Stainless steel Article number: 38108100100 Mounting plate Stainless steel Article number: 38108100000 Standard bracket set Stainless steel Article number: 38108100150 Stainless steel Article number: 38108100200 GOST Visual Ex signaling devices Manufacturer s declaration We hereby declare that the explosion-protected fl ashing light with the type designation Ex-CWB-ATEX has been developed and manufactured in accordance with EN 60079-0. This declaration is based on compliance with the following regulations and standards: EN 60079-0 Electrical equipment for areas at risk of explosions General requirements 94/9/EG EN 61241-0 Electrical equipment for use in areas with combustible dust EN 60079-1 EN 60529 Types of protection by enclosure (IP code) EN 60079-7 EN 60400 / IEC 61 Lamp sockets for tube-shaped fl uorescent lamps and starter sockets EN 60598 2004/108/EG Electromagnetic compatibility The flashing light is approved for use in potentially explosive areas in Zones 1, 2, 21 and 22 as per 94/9/EU. CE conformity Pressure-resistant encapsulation d Enhanced safety e Lights Further technical information can be found on our website at www.pfannenberg.com 199

EX SIGNALING DEVICES FLASHING LIGHTS 5/10/15 J BExBG05 / BExBG10 / BExBG15 ATEX The fl ashing light is ideal for almost all mounting requirements: side, ceiling and fl oor mounting categories 2G (Zones 1 and 2), 2D (Zones 21 and 22) extremely bright at up to 15 joules fl ash energy large connection box for simple mounting also available with connection box in increased safety version very sturdy, manufactured from seawater-resistant aluminium and stainless steel protection cage BExBG05 can be mounted in all operating positions 5 Joules 10 Joules 15 Joules r = 11 m r = 17 m r = 23 m IP 67 + 70 C - 50 C Covering distance as per EN 54 Covering distance as per EN 54 Covering distance as per EN 54 Protection system Operating temperature Electrical data AC BExBG05 BExBG10 BExBG15 Rated voltage 230 V AC 115 V AC 230 V AC 115 V AC 230 V AC 115 V AC Rated frequency 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz Operating range ± 10% ± 10% ± 10% ± 10% ± 10% ± 10% Nominal current consumption 55 ma 140 ma 110 ma 250 ma 170 ma 360 ma Electrical data DC BExBG05 BExBG10 BExBG15 Rated voltage 48 V DC 24 V DC 12 V DC 48 V DC 24 V DC 12 V DC 48 V DC 24 V DC Operating range ± 25% ± 25% ± 25% ± 25% ± 25% ± 25% ± 25% ± 25% Nominal current consumption 180 ma 300 ma 750 ma 340 ma 660 ma 1450 ma 480 ma 860 ma Mechanical data BExBG05D/BExBG05E BExBG10D/BExBG10E BExBG15D/BExBG15E Type of protection Ex d IP 67 / Ex de IP 66 Explosion protection 1 Category (area of use) II2G Ex d IIC T4, T5 or T6 II2G Ex de IIC T4, T5 or T6 II2D Ex td A21 IP67 T85, T100 or T115 II2G Ex d IIC T4 or T5 II2G Ex de IIC T4 or T5 II2D Ex td A21 IP67 T95, T110 or T125 2G (Zone 1, 2) 2D (Zone 21, 22) Certificate of conformity KEMA 01 ATEX 2030 Testing body KEMA Flash energy 5 J 10 J 15 J Flash rate 60 fl ashes/min., stabilised Lens colours clear, yellow, amber, red, green, blue Temperature class T T4 / T115 C @ Ta - 50 C... + 70 C T5 / T100 C @ Ta - 50 C... + 55 C T6 / T85 C @ Ta - 50 C... + 40 C T4 / T125 C @ Ta - 50 C... + 70 C T110 C @ Ta - 50 C... + 55 C T5 / T85 C @ Ta - 50 C... + 40 C Storage temperature - 50 C + 70 C Relative humidity 90% Duty cycle 100% Service life of the flash tube light emission still 70% after 8,000,000 fl ashes Material lensglass housing die-cast aluminium, resistant to salt water, marine grade LM6, red (RAL 3000) protective cage and bracket stainless steel Type of connection 1 x 4 mm 2 or 2 x 2.5 mm 2 Cable entry 1 2 x M20, of which one open, optionally PG13.5 or 1/2 NPT Weight Exd 2.45 kg Exde 2.75 kg 1 Ex cable gland not included 200 www.pfannenberg.com

Dimensions Ex d Ex de 165 151.5 145 164.5 226.5 239.5 63 75 63 75 30 30 mounting holes 3 x 7 mm Ø Ordering details Article numbers BExBG05-E BExBG05-D Lens colour Rated voltage 230 V AC 24 V DC 230 V AC 24 V DC yellow 311 30 10 3 000 311 30 80 3 000 311 31 10 3 000 311 31 80 3 000 amber 311 30 10 4 000 311 30 80 4 000 311 31 10 4 000 311 31 80 4 000 red 311 30 10 5 000 311 30 80 5 000 311 31 10 5 000 311 31 80 5 000 Article numbers BExBG10-E BExBG10-D Lens colour Rated voltage 230 V AC 24 V DC 230 V AC 24 V DC yellow 311 20 10 3 000 311 20 80 3 000 311 21 10 3 000 311 21 80 3 000 amber 311 20 10 4 000 311 20 80 4 000 311 21 10 4 000 311 21 80 4 000 red 311 20 10 5 000 311 20 80 5 000 311 21 10 5 000 311 21 80 5 000 Article numbers BExBG15-E BExBG15-D Lens colour Rated voltage 230 V AC 24 V DC 230 V AC 24 V DC yellow 311 10 10 3 000 311 10 80 3 000 311 11 10 3 000 311 11 80 3 000 amber 311 10 10 4 000 311 10 80 4 000 311 11 10 4 000 311 11 80 4 000 red 311 10 10 5 000 311 10 80 5 000 311 11 10 5 000 311 11 80 5 000 Article numbers for other colours and voltages on request Options / Accessories GOST Visual Ex signaling devices Manufacturer s declaration We hereby declare that the explosion-protected fl ashing light with the type designation BExBG05 15 d or e ATEX has been developed and manufactured in accordance with section 5.1.2 of EN 50014. This declaration is based on compliance with the following regulations and standards: 94/9/EG CE conformity EN 50014 Electrical equipment for areas at risk of explosions General requirements EN 50018 Pressure-resistant encapsulation d EN 50019 Enhanced safety e EN 50281-1-1 Electrical equipment for use in areas with combustible dust EN 60529 Types of protection by enclosure (IP code) 89/336/EWG Electromagnetic compatibility The Ex-BExBG05-15 d or e flashing lights are approved for use in potentially explosive areas in Zones 1, 2, 21 and 22 as per 94/9/EU. Further technical information can be found on our website at www.pfannenberg.com 201

EX SIGNALING DEVICES LED LIGHT BExBG L1D ATEX The LED light is ideal for almost all mounting requirements: side, ceiling and fl oor mounting categories 2G (Zones 1 and 2), 2D (Zones 21 and 22) large connection box for simple mounting also available with connection box in increased safety version very sturdy, manufactured from seawater-resistant aluminium and stainless steel protection cage can be mounted in all operating positions a total of 9 different operating modes can be set 2 additional operating modes can be controlled externally r = 5 m Covering distance as per EN 54 IP 67 Protection system + 55 C - 50 C Operating temperature Electrical data Rated voltage Rated frequency BExBG L1D 230 V AC 50 / 60 Hz Operating range ± 10% Nominal current consumption 70 ma Mechanical data BExBG L1D Type of protection Ex d IP 67 II 2G EEx d IIC T4 or T5 Explosion protection 1 II 2G EEx de IIC T4 or T5 II 2D T135 C or T100 C Category (area of use) 2G (Zone 1, 2) 2D (Zone 21, 22) Certificate of conformity KEMA 01 ATEX 2006 X Testing body Light source KEMA 32 LEDs Lens colours yellow, amber, red, green, blue Temperature class T T4 / T135 C @ Ta - 50 C... + 55 C T5 / T100 C @ Ta - 50 C... + 40 C Storage temperature - 50 C + 70 C Relative humidity 90% Duty cycle 100% Service life of the flash tube > 50,000 hrs lensglass Material housing die-cast aluminium, resistant to salt water, marine grade LM6, red (RAL 3000) protective cage and bracket stainless steel Type of connection 1 x 4 mm 2 or 2 x 2.5 mm 2 Cable entry 1 2 x M20, of which one open, optionally PG13.5 or 1/2 NPT Weight 2.75 kg 1 Ex cable gland not included 202 www.pfannenberg.com

Dimensions EEx d EEx de 165 151.5 145 164.5 226.5 239.5 63 75 63 75 30 30 mounting holes 3 x 7 mm Ø Operating modes Mode internal external stage 1 stage 2 stage 3 1 all on 9 8 2 rotation 3 LED fast ON 7 1 3 rotation 6 LED fast ON 8 1 4 rotation 3 LED slow ON 9 1 5 rotation 6 LED slow ON 6 1 Mode internal external stage 1 stage 2 stage 3 6 double fl ash 1 Hz 9 1 7 single fl ash 2 Hz 3 1 8 double fl ash 2 Hz 3 1 9 alternating fl ash 1:1 2 Hz 3 1 Ordering details Article numbers BExBG L1D Lens colour Rated voltage 230 V AC amber 311 51 10 4 000 Article numbers for other colours and voltages on request Options / Accessories GOST Visual Ex signaling devices Manufacturer s declaration We hereby declare that the explosion-protected LED light with the type designation BExBG L1D ATEX has been developed and manufactured in accordance with section 5.1.2 of EN 50014. This declaration is based on compliance with the following regulations and standards: 94/9/EG CE conformity EN 50014 Electrical equipment for areas at risk of explosions General requirements EN 50018 Pressure-resistant encapsulation d EN 50019 Enhanced safety e EN 50281-1-1 Electrical equipment for use in areas with combustible dust EN 60529 Types of protection by enclosure (IP code) 89/336/EWG Electromagnetic compatibility The BExBG L1D ATEX LED light is approved for use in potentially explosive areas in Zones 1, 2, 21 and 22 as per 94/9/EU. Further technical information can be found on our website at www.pfannenberg.com 203

EX SIGNALING DEVICES IS-MINI LED BLINKING LIGHT IS-mB1 Very economical visual alarm certifi ed for use in Ex-Zones 0, 1 and 2! compact design with a diameter of just 88 mm blinking light operated via certifi ed zener barriers or galvanic isolators super-bright LEDs in red, green, blue and yellow/amber very well suited for fi re alarm systems and direct control due to low power consumption See pages 224 and 225 for suitable zener barriers r = 4 m Covering distance as per EN 54 IP 65 Protection system + 60 C - 40 C Operating temperature Electrical data Rated voltage Operating range IS-mB1 24 V DC 16 28 V Nominal current consumption 25 ma 1 1 typical for connection to 24 V DC via 28 V / 300 Ω zener barrier. Power must be connected via a zener barrier (max. 28 V DC, 93 ma DC, 0.66 W) or a galvanic isolator, specifi ed by the system certifi cate (see page 225) Mechanical data IS-mB1 Type of protection ia inherently safe Explosion protection II 1G EEx ia IIC T4 1G (Zone 0) Category (area of use) 2G (Zone 1) 3G (Zone 2) Certificate SIRA 05 ATEX2084 X Testing body SIRA Flash rate can be set to 2 Hz or 1 Hz Lens colour clear, with red, yellow/amber, blue or green LEDs Temperature class T T4 @ Ta - 40 C... + 60 C Storage temperature - 40 C + 70 C Relative humidity 90% Protection system according to EN 60529 IP 65 Duty cycle 100% Material lens polycarbonate (PC) housing ABS, self-extinguishing UL94V0 & 5VA, similar to RAL 3000 (fl ame red) Connecting terminals 0.5 2.5 mm 2 Cable entry 2 x M20 (knock-outs prepared) Weight 210 g 204 www.pfannenberg.com

Dimensions Ø 88.7 85 M20 95 85.5 A/F M20 Connection diagram seal connecting terminals frequencies frequency setting Ordering details Article numbers IS-mB1 Colour Rated voltage 24 V DC yellow/amber 310 08 80 4 000 red 310 08 80 5 000 green 310 08 80 6 000 blue 310 08 80 7 000 Options / Accessories Visual Ex signaling devices GOST Zener barrier See pages 242/243 for further information Manufacturer s declaration Developed and manufactured in accordance with the following regulations and standards: EN 50014 EN 50020 EN 50284 Electrical equipment for areas at risk of explosions General requirements Electrical equipment for areas at risk of explosions intrinsically safety i Special requirements for the design, testing and marking of electrical equipment in appliance group II, category 1G Further technical information can be found on our website at www.pfannenberg.com 205

EX SIGNALING DEVICES SOUNDERS 105/110 db(a) DS 5 / DS 10 3G/3D ATEX Gas and dust protection the industrial sounder for tough applications. Proven 100,000 times over in shipping. When nothing else works, this still does! Heavy duty but still light! for use as an acoustic alarm in potentially explosive workplaces of category 3G (Zone 2) and 3D (Zone 22) category for gas and dust protection IP 67 for safe operation under extreme environmental conditions individual selection of 32 different tones optionally: 4-stage external tone selection (options: TAS, TAV) all tones can be individually combined with one another when externally controlled (programming function, tone 32) DS 5 3G/3D DS 10 3G/3D r = 32 m r = 56 m IP 66 IP 67 + 55 C - 25 C VdS G28609 EN 54-3 10 Years max. covering distance max. covering distance Protection system Operating temperature Warranty Electrical data DS 5 3G/3D Rated voltage230 V AC 115 V AC 24 V AC 1 24 V DC 12 V DC Rated frequency 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz Operating range 195 253 V 95 127 V 19 29 V 19 29 V 10 15 V Nominal current consumption 0.03 A 0.06 A 0.28 A 0.28 A 0.28 A Electrical data DS 10 3G/3D Rated voltage230 V AC 115 V AC 24 V AC 1 24 V DC 12 V DC Rated frequency 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz Operating range 195 253 V 95 127 V 19 29 V 19 29 V 10 15 V Nominal current consumption 0.06 A 0.12 A 0.42 A 0.42 A 0.3 A 1 Temperature class T3 Mechanical data DS 5 3G/3D DS 10 3G/3D II 3G Ex na II T4 (all voltages except 24 V AC) Explosion protection II 3G Ex na II T3 (only 24 V AC) II 3D Ex td A22 IP 67 T135 C Category (area of use) 3G (Zone 2), 3D (Zone 22) Testing body Pfannenberg Sound pressure level 105 db (A) ± 3 db (A) 110 db (A) ± 3 db (A) Alarm tones 32 / 2-stage alarm Temperature class T4 / T3 @ - 25 C... + 55 C Storage temperature - 40 C... + 70 C Protection system according to EN 60529 IP 66, IP 67 Duty cycle 100% Material die-cast aluminium GD-AI Si12 Cu Surface coating epoxy resin paint RAL 3000, fl ame red Cable bushing 2 x M20 x 1.5 (1 x plastic cable gland, 1 x plug) Clamping range of the cable fitting 6 13 mm Connecting terminal cross-section min. 0.08 mm 2... max. 2.5 mm 2 AWG 28-12 (AWG12 THHN, THWN) Weight AC: 2.15 kg / DC: 1.95 kg Options / Accessories External tone selection control / 4-stage external tone selection TAV: control by means of external voltage input (12 V and 24 V DC only) TAS: control by means of control voltage GOST GL 30457-83-HH 206 www.pfannenberg.com

Dimensions Ø 7 143 M20 x 1.5 133.5 150 M20 blanking plug 71.5 71.5 Tone table Tone Description - Basic tone (preset: tone no. 1) Stage 2 3 4 0 no tone 1 5 4 1 1 Sawtooth, DIN tone 33404-3 Germany (emergency signal), PFEER PTAP 2 Interrupted tone, ISO 8201 (emergency evacuation signal) 3 2 4 1 4 3 3 Alternating tone 1 2 4 4 Continuous tone, UK BS5839-1 950 Hz 1 3 5 5 Interrupted tone 1 4 3 6 Sweeping 1 4 9 7 8 Alternating tone, France NFS 32-001 (fi re alarm) Interrupted tone, Sweden SS031711 (emergency signal) 3 10 4 2 3 4 9 Interrupted tone (fast), horn 1 3 4 10 Continuous tone 500 Hz 27 9 26 11 Continuous tone 725 Hz 1 17 9 12 Continuous tone 825 Hz EN54-3 27 9 26 13 Continuous tone 1200 Hz 1 5 3 14 Continuous tone 1500 Hz 1 4 10 15 Interrupted tone 1 24 12 16 Interrupted tone 1 24 15 17 Interrupted tone 1 11 9 1 factory setting 1200 Hz 500 Hz 950 Hz 1025 Hz 825 Hz 950 Hz 500 Hz 825 Hz 725 Hz 1 s EN54-3 0.25 s 0.25 s 1 s 1 s 1200 Hz 3 s 500 Hz 3 s 554 Hz 440 Hz 0.4 s 700 Hz 800 Hz 0.5 s 0.5 s 0.1 s 1.5 s 0.125 s 0.125 s 4 ms 4 ms 0.5 s 0.5 s 0.5 s 0.5 s 0.7 s 0.3 s EN54-3 Tone Description - Basic tone (preset: tone no. 1) Stage 2 3 4 18 Interrupted tone 19 7 4 19 20 21 22 Alternating tone, UK BS5839-1 (fi re alarm, railway crossing) Interrupted tone, IMO SOLAS III/50 + SOLAS III/6.4 (general alarm) Interrupted tone, IMO (leave ship) Slow whoop, evacuation alarm Netherlands NEN 2575 27 13 23 9 21 26 20 9 26 19 14 2 23 Siren 27 12 2 24 Alternating tone 1 16 12 25 Alternating tone 1 14 5 26 Alternating tone 4 9 27 27 Siren 13 23 19 28 Sweeping 7 10 4 29 30 Pulsating tone, industrial alarm Germany Interrupted tone, industrial alarm (Germany) 800 Hz 2.5 s 825 Hz 950 Hz 1 30 9 1 4 26 31 Sweeping, France NFC48-265 3 14 4 1200 Hz 500 Hz 32 selection of available tone combinations in stages 2, 3 and 4 2.5 s 0.25 s 1000 Hz 0.25 s 800 Hz 1 s 3.5 s 3 s 7 s 1 s 1 s 0.5 s 1 s 0.25 s EN54-3 EN54-3 2400 Hz 3 s const. 500 Hz 1075 Hz 0.5 s 825 Hz 0.5 s 900 Hz 0.25 s 500 Hz 1400 Hz 0.25 s 20 ms 1200 Hz 20 ms 1200 Hz 3 s const. 300 Hz 1500 Hz 1.5 s 700 Hz 1.5 s 1000 Hz 10 s 40 s 150 Hz 680 Hz 0.875 s 0.875 s 1600 Hz 1 s 1400 Hz 0.5 s 10 s Ordering details Article numbers DS 10 3G/3D DS 5 3G/3D Version Rated voltage 230 V AC 115 V AC 24 V DC 230 V AC 115 V AC 24 V DC Standard 231 11 10 0 007 231 11 15 0 007 231 11 80 0 007 231 06 10 0 007 231 06 15 0 007 231 06 80 0 007 TAS 231 11 10 0 155 231 11 15 0 155 231 11 80 0 155 231 06 10 0 155 231 06 15 0 155 231 06 80 0 155 Article numbers for other voltages and versions on request Manufacturer s declaration We hereby declare that the explosion-protected means of alarm with the type designation DS 10 3G/3D, DS 5 3G/3D fullfi ls the requirements of the EN 60079-0, EN 60079-15, EN 61241-0 and EN 61241-1 standards in their latest editions. This declaration is based on compliance with the following regulations and standards: DIN EN 60079-0 Electrical equipment for areas at risk of gas explosions UVV-BGV A3 (VBG4) Electrical plants and equipment - General requirements DIN EN 54-3 Fire alarm systems Part 3: fi re alarm devices; Acoustic alarms DIN EN 60079-15 Electrical equipment for areas at risk of gas explosions DIN EN 981 Machine safety - System of acoustic and visual alarm signals - Type of protection n and information signals DIN EN 61241-0 Electrical equipment for use in areas with combustible dust DIN EN 50262 Metric cable glands for electrical installations - General requirements DIN IEC 60038 IEC standard voltages DIN EN 61241-1 Electrical equipment for use in areas with combustible dust DIN 33404/3 Alarm signals for workplaces; acoustic alarm signals; uniform - part 1: protection by enclosure td emergency signal; technical safety requirements, tests DIN EN 61000-6-2 Generic standard, interference immunity for industrial areas DIN EN 60947-1 Low-voltage switchgear Part 1: General specifi cations DIN EN 61000-6-3 Generic standard, interference emission for residential areas DIN EN 60950-1 Safety of information technology equipment DIN EN 50130-4 Electromagnetic compatibility; product family standard: requirements for the interference immunity of system components DIN EN 60529 Types of protection by enclosure (IP code) for fire and burglar alarms and well as social alarm systems DIN EN ISO7731 Ergonomic alarms for public areas and workplaces acoustic alarms 9. GPSG Appliance and product safety act Guideline 94/9/EG (ATEX 100a) DIN EN 60079-0 / DIN EN 60079-15 / DIN EN 61241-0 / DIN EN 61241-1 The DS 10 3G/3D, DS 5 3G/3D sounders are approved for use in potentially explosive areas in Zones 2 and 22 as per 94/9/EU. Acoustic Ex signaling devices Further technical information can be found on our website at www.pfannenberg.com 207

EX SIGNALING DEVICES SOUNDERS 117 db(a) BExS 120 d/e / BExDS 120 d/e 32 different tones can be set; UKOOA/PFEER conform 117 db (A) ± 3 db (A) sound pressure 3 externally selectable tones positive and negative control possible in the case of DC devices quartz-stabilised tone synchronisation adjustable volume (except 12 V DC) ATEX and optionally IECEx approval housing made of die-cast aluminium LM6, horn made of ABS stainless steel mounting bracket for 360 positioning categories 2G and 3G (Zones 1 and 2) also available as categories 2D & 3D (Zones 21 & 22) for dust zones amendment 2; extended approval/temperature range + 70 C r = 126m IP 66 IP 67 + 70 C - 50 C EN 54-3 VdS G209081 max. covering distance Protection system Operating temperature Exd 24 V DC Exd 24 V DC Electrical data BExS 120 d/e / BExDS 120 d/e Rated voltage 230 V AC 115 V AC 48 V DC 24 V DC 12 V DC Rated frequency 50 / 60 Hz 50 / 60 Hz Operating range ± 10% ± 10% ± 25% ± 25% ± 25% Nominal current consumption 90 ma 180 ma 420 ma 800 ma 850 ma Mechanical data BExS 120 d/e BExDS 120 d/e Protection system d = IP 67; or e = IP 66 Explosion protection Category (area of use) II 2G Ex d IIC T4 / II 2G Ex de IIC T4 II 2G Ex d IIB T4 / II 2G Ex de IIB T4 2G (Zone 1) 3G (Zone 2) II 2G/D Ex d IIC T4 100 C / II 2G/D Ex de IIC T4 100 C II 2G/D Ex d IIB T4 115 C / II 2G/D Ex de IIB T4 115 C 2G (Zone 1) / 2D (Zone 21) 3G (Zone 2) / 3D (Zone 22) Certificate of conformitykema 99 ATEX 7906 KEMA 99 ATEX 6312 Testing body KEMA KEMA Sound pressure level 117 db (A) ± 3 db (A) 117 db (A) ± 3 db (A) Temperature class T IIC: T4 @ - 50 C... + 55 C Ta IIB: T4 @ - 50 C... + 70 C Ta T4 @ - 50 C... + 55 C Ta Sound level reduction by - 9 db Storage temperature - 50 C + 70 C Relative humidity 90% Duty cycle 100% Material housing die-cast aluminium LM6, similar to RAL 3000 (fl ame red) horn ABS self-extinguishing, similar UL 94 VO & 5VA FR ABS, Ex II 2D anti-static ABS, black Connecting terminals Exd 1 x 4 mm 2 or 2 x 2.5 mm 2 Exde 2 x 2.5 mm 2 Cable entry 2 / 1 x closed, 1 x open (M20), optionally PG13.5 or 1/2 NPT Weight Exd AC: 3.88 kg / DC: 3.42 kg Exde AC: 4.14 kg / DC: 3.38 kg Options / Accessories GOST IECEx No SIM 04.0001 Exd BExDS 208 www.pfannenberg.com

Dimensions 162 145 Ø 220 7 (3x) Exd: 313 Exde: 326 30 30 Tone table Tone Description - Basic tone Stage 2 3 1 Continuous tone 1000 Hz 31 11 2 Alternating tone, UK BS5839-1 (fi re alarm, railway crossing) 17 5 3Slow whoop 2 5 4Sweeping (fast) 6 5 5Continuous tone 2400 Hz 3 27 6Sweeping 7 5 7Sweeping (fast) 10 5 8Sweeping 2 5 9 Sawtooth, DIN tone 33404-3 Germany (emergency signal), PFEER PTAP 15 2 10Alternating tone 7 5 11Interrupted tone 31 1 12Alternating tone 4 5 13Interrupted tone 15 5 14Interrupted tone 4 5 15Continuous tone 800 Hz 2 5 16Interrupted tone 18 5 17 Alternating tone, France NFS 32-001 (fi re alarm) 1000 Hz 0.25 s 800 Hz 0.25 s 1200 Hz 3.0 s 500 Hz 1000 Hz 1200 Hz 500 Hz 2900 Hz 2400 Hz 1000 Hz 1000 Hz 0.875 s 800 Hz 0.875 s 2400 Hz 800 Hz 554 Hz 440 Hz 660 Hz 800 Hz 10 ms 2900 Hz 2400 Hz 70 ms 2900 Hz 10 ms 2400 Hz 10 ms 1200 Hz 3 s 500 Hz 3 s 0.1 s 0.25 s 20 ms 10 ms 10 ms 10 ms 10 ms 0.4 s 1 s 150 ms 150 ms 0.5 s 10 ms 70 ms 1 s EN54-3 20 ms EN54-3 EN54-3 EN54-3 2 27 Tone Description - Basic tone Stage 2 3 18 660 Hz Interrupted tone, Sweden SS031711 (air raid warning) 1.8 s 1.8 s 2 5 1600 Hz 1 s 19Sweeping, France NFC48-265 2 5 1400 Hz 0.5 s 20 Continuous tone, Sweden SS031711 (all-clear signal) 660 Hz 2 5 21Alternating tone 554 Hz 10 ms 440 Hz 10 ms 2 5 544 Hz 22Interrupted tone 2 5 0.875 s 0.875 s 800 Hz 23Interrupted tone 6 5 20 ms 20 ms 1000 Hz 0.5 s 24 Sweeping (medium), UK BS5839-1 29 5 800 Hz 0.5 s 2900 Hz 0.5 s 25 Sweeping 29 5 2400 Hz 0.5 s 1450 Hz 26Simulated bell 2 1 0.69 ms 27Continuous tone 554 Hz 26 5 28Continuous tone 440 Hz 2 5 1000 Hz 70 ms 29 Sweeping (fast), UK BS5839-1 7 5 800 Hz 70 ms 30 420 Hz Interrupted tone, Australia AS2220, AS1610, AS1670 0.625 s 0.625 s 32 5 31 1200 Hz 1 s Sweeping, IMO 3d, Germany KTA3901 evacuation alarm 500 Hz 1 s 11 1 32 Slow whoop, Australian evacuation alarm AS2220 1200 Hz 3.75 s 500 Hz The sounder can be set externally to the respective tones of stage 2 & 3. Tone 2 is preset. 0.25 s 26 1 Acoustic Ex signaling devices Ordering details Article numbers BExS 120D BExS 120E BExDS 120D BExDS 120E Rated voltage 230 V AC 24 V DC 230 V AC 24 V DC 230 V AC 230 V AC 320 76 10 0 000 320 76 80 0 000 320 78 10 0 000 320 78 80 0 000 320 89 10 0 000 320 81 10 0 000 Article numbers for other voltages on request Further technical information can be found on our website at www.pfannenberg.com 209

EX SIGNALING DEVICES SOUNDERS 110 db(a) BExS 110 d/e / BExDS 110 d/e 32 different tones can be set; UKOOA/PFEER conform 110/117 db (A) ± 3 db (A) sound pressure 3 externally selectable tones positive and negative control possible in the case of DC devices quartz-stabilised tone synchronisation adjustable volume (except 12 V DC) ATEX and optionally IECEx approval housing made of die-cast aluminium LM6, horn made of ABS stainless steel mounting bracket for 360 positioning categories 2G and 3G (Zones 1 and 2) also available as categories 2D & 3D (Zones 21 & 22) for dust zones amendment 2; extended approval/temperature range + 70 C r = 56m IP 66 IP 67 + 70 C - 50 C EN 54-3 VdS G209081 max. covering distance Protection system Operating temperature Exd 24 V DC Exd 24 V DC Electrical data BExS 110 d/e / BExDS 110 d/e Rated voltage 230 V AC 115 V AC 48 V DC 24 V DC 12 V DC Rated frequency 50 / 60 Hz 50 / 60 Hz Operating range ± 10% ± 10% ± 25% ± 25% ± 25% Nominal current consumption 56 ma 110 ma 130 ma 250 ma 195 ma Mechanical data BExS 110 d/e BExDS 110 d/e Protection system d = IP 67; or e = IP 66 Explosion protection Category (area of use) II 2G Ex d IIC T4 / II 2G Ex de IIC T4 II 2G Ex d IIB T4 / II 2G Ex de IIB T4 2G (Zone 1) 3G (Zone 2) II 2G/D Ex d IIC T4 100 C / II 2G/D Ex de IIC T4 100 C II 2G/D Ex d IIB T4 115 C / II 2G/D Ex de IIB T4 115 C 2G (Zone 1) / 2D (Zone 21) 3G (Zone 2) / 3D (Zone 22) Certificate of conformitykema 99 ATEX 7906 KEMA 99 ATEX 6312 Testing body KEMA KEMA Sound pressure level 110 db (A) ± 3 db (A) 110 db (A) ± 3 db (A) Temperature class T IIC: T4 @ - 50 C... + 55 C Ta IIB: T4 @ - 50 C... + 70 C Ta T4 @ - 50 C... + 55 C Ta Storage temperature - 50 C + 70 C Relative humidity 90% Duty cycle 100% Material housing die-cast aluminium LM6, similar to RAL 3000 (fl ame red) horn ABS self-extinguishing, similar UL 94 VO & 5VA FR ABS, Ex II 2D anti-static ABS, black Connecting terminals Exd 1 x 4 mm 2 or 2 x 2.5 mm 2 Exde 2 x 2.5 mm 2 Cable entry 2 / 1 x closed, 1 x open (M20), optionally PG13.5 or 1/2 NPT Weight Exd AC: 3.42 kg / DC: 3.16 kg Exde AC: 3.68 kg / DC: 3.42 kg Options / Accessories GOST IECEx No SIM 04.0001 Exd BExDS 210 www.pfannenberg.com

Dimensions 162 145 Ø 181 Exd: 263 Exde: 275 7 (3x) 30 30 Tone table Tone Description - Basic tone Stage 2 3 1 Continuous tone 1000 Hz 31 11 2 Alternating tone, UK BS5839-1 (fi re alarm, railway crossing) 17 5 3Slow whoop 2 5 4Sweeping (fast) 6 5 5Continuous tone 2400 Hz 3 27 6Sweeping 7 5 7Sweeping (fast) 10 5 8Sweeping 2 5 9 Sawtooth, DIN tone 33404-3 Germany (emergency signal), PFEER PTAP 1000 Hz 0.25 s 800 Hz 0.25 s 1200 Hz 3.0 s 500 Hz 1200 Hz 500 Hz 2900 Hz 20 ms 2400 Hz 20 ms 15 2 10Alternating tone 7 5 1000 Hz 11Interrupted tone 31 1 1000 Hz 0.875 s 800 Hz 0.875 s 12Alternating tone 4 5 2400 Hz 13Interrupted tone 15 5 800 Hz 14Interrupted tone 4 5 15Continuous tone 800 Hz 2 5 554 Hz 16Interrupted tone 18 5 440 Hz 1000 Hz 800 Hz 10 ms 2900 Hz 2400 Hz 70 ms 2900 Hz 10 ms 2400 Hz 10 ms 1200 Hz 3 s 500 Hz 3 s 0.1 s 0.25 s 1 s EN54-3 10 ms 10 ms 10 ms 10 ms 0.4 s 0.5 s 10 ms 1 s 70 ms EN54-3 EN54-3 Tone Description - Basic tone Stage 2 3 18 660 Hz Interrupted tone, Sweden SS031711 (air raid warning) 1.8 s 1.8 s 2 5 1600 Hz 1 s 19Sweeping, France NFC48-265 2 5 1400 Hz 0.5 s 20 Continuous tone, Sweden SS031711 (all-clear signal) 660 Hz 2 5 554 Hz 21Alternating tone 10 ms 440 Hz 10 ms 2 5 544 Hz 22Interrupted tone 2 5 0.875 s 0.875 s 800 Hz 23Interrupted tone 6 5 20 ms 20 ms 1000 Hz 0.5 s 24 Sweeping (medium), UK BS5839-1 29 5 800 Hz 0.5 s 2900 Hz 0.5 s 25 Sweeping 29 5 2400 Hz 0.5 s 1450 Hz 26Simulated bell 2 1 0.69 ms 27Continuous tone 554 Hz 26 5 28Continuous tone 440 Hz 2 5 1000 Hz 70 ms 29 Sweeping (fast), UK BS5839-1 7 5 800 Hz 70 ms 30 420 Hz Interrupted tone, Australia AS2220, AS1610, AS1670 0.625 s 0.625 s 32 5 31 1200 Hz 1 s Sweeping, IMO 3d, Germany KTA3901 evacuation alarm 500 Hz 1 s 11 1 32 Slow whoop, Australian evacuation alarm AS2220 1200 Hz 3.75 s 500 Hz 0.25 s 26 1 Acoustic Ex signaling devices 17 Alternating tone, France NFS 32-001 (fi re alarm) 660 Hz 150 ms 150 ms EN54-3 2 27 The sounder can be set externally to the respective tones of stage 2 & 3. Tone 2 is preset. Ordering details Article numbers BExS 110D BExS 110E BExDS 110D BExDS 110E Rated voltage 230 V AC 24 V DC 230 V AC 24 V DC 230 V AC 230 V AC 320 80 10 0 000 320 80 80 0 000 320 82 10 0 000 320 82 80 0 000 320 75 10 0 000 320 85 10 0 000 Article numbers for other voltages on request Further technical information can be found on our website at www.pfannenberg.com 211

EX SIGNALING DEVICES SOUNDER 105 db(a) IS-A105N These sounders are used in workplaces where dangerous, explosive atmospheres are to be expected free selection of 49 different tones UKOOA/PFEER conform high sound pressure level of 105 db (A), can be reduced by up to 15 db (A) via a potentiometer up to 2 tones can be selected externally in order to signal different alarms works on DC voltages between 10 and 28 V DC, rated voltage 24 V DC can also be used outdoors thanks to housing made of self-extinguishing ABS and IP 66 protection system categories 1G, 2G and 3G (Zones 0, 1 and 2) See pages 224 and 225 for suitable zener barriers r = 32 m max. covering distance IP 66 Protection system + 60 C - 40 C Operating temperature Electrical data IS-A105N Rated voltage 24 V DC Operating range 10 28 V Nominal current consumption 25 ma (typical for connection to 24 V DC via 28 V / 300 Ω zener barrier) Power must be connected via a zener barrier (max. 28 V DC, 93 ma DC, 0.66 W) or a galvanic isolator, specifi ed by the system certifi cate (see page 225) Mechanical data IS-A105N Type of protection ia inherently safe Explosion protection II 1G Ex ia IIC T4-40 C... + 60 C Ta Category (area of use) 1G (Zone 0) / 2G (Zone 1) / 3G (Zone 2) Certificate of conformity SIRA 04 ATEX 2301 X Testing bodysira Sound pressure level up to 105 db (A) ± 3 db (A) can be reduced by up to 15 db (A) via an internal potentiometer Alarm tones 49 different tones can be set via DIP switch, of which 2 tones are externally selectable Storage temperature - 40 C + 70 C Relative humidity 90% @ + 50 C Duty cycle 100% MaterialABS self-extinguishing, similar UL 94 VO Colour similar to RAL 3000 (fl ame red), optionally grey RAL 7038 or white RAL 9010 Connecting terminals 0.5 2.5 mm 2 Cable entry 20 mm Weight 0.75 kg Dimensions 130 132 130 Ø 7.3 M20 143 212 www.pfannenberg.com

Tone table Stage Tone Description - Frequency 2 3 1 Continuous tone 340 Hz 2 5 1000 Hz Alternating tone, UK BS5839-1 0.25 s EN54-3 2 17 5 (fi re alarm, railway crossing) 0.25 s 3 Slow whoop, evacuation alarm Netherlands NEN 2575 Article number IS-A105N 24 V DC 320 33 80 0 000 2 5 4Sweeping (fast) 6 5 5Continuous tone 2400 Hz 3 20 6Sweeping 7 5 7Sweeping (fast) 10 5 8Sweeping 2 5 9 Sawtooth, DIN tone 33404-3 Germany (emergency signal), PFEER PTAP 15 2 10Alternating tone 7 5 11Interrupted tone 2 5 12Alternating tone 4 5 13Interrupted tone 15 5 14Interrupted tone 4 5 15Continuous tone 800 Hz 2 5 16Interrupted tone 18 5 17 18 Alternating tone, France NFS 32-001 (fi re alarm) Interrupted tone, Sweden SS031711 (air raid warning) 2 27 2 5 19 Sweeping, France NFC48-265 2 5 20 Continuous tone, Sweden SS031711 (all-clear signal) 2 5 21Alternating tone 2 5 22Interrupted tone 2 5 23Interrupted tone 6 5 24 Sweeping (medium), UK BS5839-1 29 5 Ordering details 800 Hz 1200 Hz 500 Hz 3.5 s 1000 Hz 0.5 s 800 Hz 10 ms 2900 Hz 10 ms 70 ms 2400 Hz 70 ms 2900 Hz 10 ms 2400 Hz 10 ms 1200 Hz 3 s EN54-3 500 Hz 3 s 1200 Hz 1 s EN54-3 500 Hz 2900 Hz 20 ms 2400 Hz 20 ms 1000 Hz 10 ms 10 ms 1000 Hz 0.875 s 800 Hz 0.875 s 2400 Hz 800 Hz 660 Hz 150 ms 150 ms 554 Hz 440 Hz 0.4 s 660 Hz 0.1 s 0.25 s 10 ms 10 ms 1 s 1.8 s 1.8 s 1600 Hz 1400 Hz 1 s 0.5 s 660 Hz 554 Hz 440 Hz 544 Hz 800 Hz 10 ms 10 ms 0.875 s 0.875 s 20 ms 20 ms 1000 Hz 0.5 s 800 Hz 0.5 s EN54-3 EN54-3 Tone Description - Frequency Stage 2 3 25Sweeping 29 5 26Simulated bell 2 15 27Continuous tone 800 Hz 26 5 28Continuous tone 440 Hz 2 5 29 Sweeping (fast), UK BS5839-1 7 5 30 Continuous tone 300 Hz 2 5 31Sweeping 26 5 32 2-tone bell sound 26 15 33 Interrupted tone 2 5 34 Alternating tone, Singapore 38 45 35 Interrupted tone, Australian alert 36 5 36 Sweeping, IMO 3d, Germany KTA3901 evacuation alarm 35 5 37 Continuous tone 1000 Hz 9 45 38 Continuous tone 2000 Hz 34 45 39 Interrupted tone 23 17 40 Alternating tone, France NFS 32-001 (fi re alarm) 31 27 41Motor siren 2 5 42Motor siren 2 5 43 Continuous tone, PFEER gasalarm 1200 Hz 2 5 44Motor siren 2 5 45 46 47 48 49 Interrupted tone, PFEER (general alarm) Sawtooth, DIN tone 33404-3 Germany (emergency signal), PFEER PTAP Interrupted tone, PFEER (general alarm) Interrupted tone, Australia AS2220, AS1610, AS1670 Sweeping, IMO 3d, Germany KTA3901 evacuation alarm 2900 Hz 2400 Hz 0.5 s 1450 Hz 1000 Hz 800 Hz 70 ms 1200 Hz 420 Hz 0.5 s 70 ms 660 Hz 10 ms 800 Hz 10 ms 650 Hz 2 s 745 Hz 10 ms 10 ms 2000 Hz 0.5 s 1000 Hz 0.5 s 800 Hz 554 Hz 0.625 s 0.625 s 1200 Hz 1 s 0.1 s 0.25 s 440 Hz 1200 Hz 800 Hz 2400 Hz 1000 Hz 1200 Hz 500 Hz 1000 Hz 420 Hz 0.25 s 0.25 s 0.69 ms 500 Hz 1 s 0.4 s 1 s EN54-3 const. const. const. 1 s 1 s 1 s EN54-3 1 s 1 s 0.625 s 0.625 s 1200 Hz 1 s 500 Hz 1 s 38 34 47 37 46 37 49 5 26 37 Acoustic Ex signaling devices Options / Accessories GOST Manufacturer s declaration Developed and manufactured in accordance with EN 50014 (general requirements), EN 50020 (intrinsically safety), EMC Directive 89/336/EEC. Further technical information can be found on our website at www.pfannenberg.com 213

EX SIGNALING DEVICES IS-MINI SOUNDER 100 db(a) IS-mA1 Very economical acoustic alarm certifi ed for use in Ex-Zones 0, 1 and 2! compact design with a diameter of just 88 m sounder operated via certifi ed zener barriers or galvanic isolators 49 loud tones at 100 db (A) very well suited for fi re alarm systems and direct control due to low power consumption self-synchronising sounder for clear tone perception 2 different externally controllable tones volume control also available as mining-certifi ed device (IM1 EEx ia) See pages 224 and 225 for suitable zener barriers r = 18 m max. covering distance IP 65 Protection system + 60 C - 40 C Operating temperature Electrical data IS-mA1 Rated voltage 24 V DC Operating range 16 28 V Nominal current consumption 25 ma (typical for connection to 24 V DC via 28 V / 300 Ω zener barrier) Power must be connected via a zener barrier (max. 28 V DC, 93 ma DC, 0.66 W) or a galvanic isolator, specifi ed by the system certifi cate (see page 225) Mechanical data IS-mA1 Type of protection ia inherently safe Explosion protection II 1G EEx ia IIC T4-40 C... + 60 C Ta Category (area of use) 1G (Zone 0) / 2G (Zone 1) / 3G (Zone 2) Certificate SIRA 05 ATEX2084 X Testing body SIRA Sound pressure level 100 db (A) Sound level reduction by - 20 db Storage temperature - 40 C + 70 C Relative humidity 90% Protection system according to EN 60529 IP 65 Duty cycle 100% Material ABS, self-extinguishing UL94VO & 5VA, similar to RAL 3000 (fl ame red) Connecting terminals 0.5 2.5 mm 2 Cable entry 2 x M20 (knock-outs prepared) Weight 230 g Dimensions Ø 88.7 99 M20 95 85.5 A/F M20 214 www.pfannenberg.com

Tone table Stage Tone Description - Frequency 2 3 1 Continuous tone 340 Hz 2 5 1000 Hz Alternating tone, UK BS5839-1 0.25 s EN54-3 2 17 5 (fi re alarm, railway crossing) 0.25 s 3 Slow whoop, evacuation alarm Netherlands NEN 2575 2 5 4Sweeping (fast) 6 5 5Continuous tone 2400 Hz 3 20 6Sweeping 7 5 7Sweeping (fast) 10 5 8Sweeping 2 5 9 Sawtooth, DIN tone 33404-3 Germany (emergency signal), PFEER PTAP 800 Hz 1200 Hz 500 Hz 15 2 10Alternating tone 7 5 11Interrupted tone 2 5 12Alternating tone 4 5 13Interrupted tone 15 5 14Interrupted tone 4 5 15Continuous tone 800 Hz 2 5 16Interrupted tone 18 5 3.5 s 1000 Hz 0.5 s 800 Hz 10 ms 2900 Hz 10 ms 2400 Hz 70 ms 2900 Hz 10 ms 2400 Hz 10 ms 1200 Hz 3 s 70 ms EN54-3 500 Hz 3 s 1200 Hz 1 s EN54-3 500 Hz 2900 Hz 20 ms 2400 Hz 20 ms 1000 Hz 10 ms 10 ms 1000 Hz 0.875 s 800 Hz 0.875 s 2400 Hz 800 Hz 660 Hz 0.25 s 10 ms 10 ms 1 s 150 ms 150 ms EN54-3 Tone Description - Frequency Stage 2 3 25Sweeping 29 5 26Simulated bell 2 15 27Continuous tone 800 Hz 26 5 28Continuous tone 440 Hz 2 5 29 Sweeping (fast), UK BS5839-1 7 5 30 Continuous tone 300 Hz 2 5 31Sweeping 26 5 32 2-tone bell sound 26 15 33 Interrupted tone 2 5 34 Alternating tone, Singapore 38 45 420 Hz 35 Interrupted tone Australian alert 36 5 36 Sweeping, IMO 3d, Germany KTA3901 evacuation alarm 35 5 37 Continuous tone 1000 Hz 9 45 38 Continuous tone 2000 Hz 34 45 39 Interrupted tone 23 17 40 Alternating tone, France NFS 32-001 (fi re alarm) 2900 Hz 2400 Hz 0.5 s 1450 Hz 1000 Hz 800 Hz 70 ms 1200 Hz 31 27 41Motor siren 2 5 0.5 s 70 ms 660 Hz 10 ms 800 Hz 10 ms 650 Hz 2 s 745 Hz 10 ms 10 ms 2000 Hz 0.5 s 1000 Hz 0.5 s 800 Hz 554 Hz 0.625 s 0.625 s 1200 Hz 1 s 500 Hz 1 s 0.1 s 440 Hz 1200 Hz 0.25 s 0.25 s 0.25 s 0.69 ms 0.4 s 1 s EN54-3 const. 17 Alternating tone, France NFS 32-001 (fi re alarm) 554 Hz 440 Hz 0.1 s 0.4 s EN54-3 2 27 800 Hz const. 42Motor siren 2 5 18 Interrupted tone, Sweden SS031711 (air raid warning) 2 5 19 Sweeping, France NFC48-265 2 5 20 Continuous tone, Sweden SS031711 (all-clear signal) 660 Hz 1.8 s 1.8 s 1600 Hz 1400 Hz 1 s 0.5 s 660 Hz 554 Hz 2 5 21Alternating tone 2 5 440 Hz 544 Hz 22Interrupted tone 2 5 800 Hz 10 ms 10 ms 0.875 s 0.875 s 23Interrupted tone 6 5 20 ms 20 ms 1000 Hz 0.5 s 24 Sweeping (medium), UK BS5839-1 29 5 800 Hz 0.5 s 43 Continuous tone, PFEER gasalarm 1200 Hz 2 5 44Motor siren 2 5 45 46 47 48 49 Interrupted tone, PFEER (general alarm) Sawtooth, DIN tone 33404-3 Germany (emergency signal), PFEER PTAP Interrupted tone, PFEER (general alarm) Interrupted tone, Australia AS2220, AS1610, AS1670 Sweeping, IMO 3d, Germany KTA3901 evacuation alarm 2400 Hz 1000 Hz 1200 Hz 500 Hz 1000 Hz 420 Hz const. 1 s 1 s 1 s EN54-3 1 s 1 s 0.625 s 0.625 s 1200 Hz 1 s 500 Hz 1 s 38 34 47 37 46 37 49 5 26 37 Acoustic Ex signaling devices Ordering details Article numbers Rated voltage IS-mA1 24 V DC 320 34 80 0 000 Options / Accessories GOST Further technical information can be found on our website at www.pfannenberg.com 215

EX SIGNALING DEVICES LOUDSPEAKERS 117/113 db(a) BExL 25 d/e / BExL 15 d/e EEx d IIC T4 / EEx de IIC T4 KEMA certifi ed ATEX approval, optionally IEC and GOST approvals housing made of die-cast aluminium LM6, horn made of ABS categories 2G and 3G (Zones 1 and 2) also available as category 2D/3D for dust zones 21 and 22 chromated polyester powder coating, resistant to moisture and salt spray, good resistance to most acids, alkalis and oils BExL 15 BExL 25 r = 79 m r = 126 m IP 66 IP 67 + 70 C - 50 C max. covering distance max. covering distance Protection system Operating temperature Mechanical data BExL 25 d/e BExL 15 d/e Protection system d = IP 67; or e = IP 66 Explosion protection II 2G Ex d IIC T4 / II 2G EEx de IIC T4 II 2G Ex d IIB T4 / II 2G EEx de IIB T4 Category (area of use) 2G (Zone 1) 3G (Zone 2) Certificate of conformitykema 99 ATEX 7906 Testing body KEMA Sound pressure level 117 db (A) ± 3 db (A) @ 25 W 113 db (A) ± 3 db (A) @ 15 W Rated power sine wave 25 W 15 W 100 V power 25 W / 12.5 W / 6 W / 2 W taps Transformer type (Z = 400 Ω / 800 Ω / 1.67 kω / 5 kω) Impedance type 8 Ω or 16 Ω 100 V power 15 W / 7.5 W / 3 W / 1 W taps (Z = 666.87 Ω / 1.34 kω / 3.34 kω / 10 kω) Dispersion 130 @ 1 khz / 32 @ 4 khz 120 @ 1 khz / 32 @ 4 khz Frequency range 300 Hz 8,000 Hz 400 Hz 8,000 Hz Temperature class T IIC T4 @ - 50 C... + 55 C Ta IIB T4 @ - 50 C... + 70 C Ta Storage temperature - 50 C + 70 C Relative humidity 90% Duty cycle 100% Material housing die-cast aluminium LM6, similar to RAL 3000 (fl ame red) horn ABS self-extinguishing, similar UL 94 VO & 5VA FR ABS, Ex II 2GD anti-static ABS, black Connecting terminals 1 x 4 mm 2 or 2 x 2.5 mm 2 Cable entry 2 / 1 x closed, 1 x open (M20), optionally PG13.5 or 1/2 NPT Weight transformer d : 3.95 kg / e : 4.21 kg d : 3.45 kg / e : 3.10 kg impedance d : 3.56 kg / e : 3.82 kg d : 3.71 kg / e : 3.36 kg 216 www.pfannenberg.com

Dimensions BExL 25 d/e BExL 15 d/e 162 Ø 220 Ø 181 Exd: 313 Exde: 326 7 (3x) 145 Exd: 263 Exde: 275 30 30 Connection diagram EEx d, 8 Ω and 16 Ω EEx e, 8 Ω and 16 Ω connection internal potential equalisation 2 x M20 cable entries internal earth terminal 100 V Connections BExL 25 d (25 W) BExL 15 d (15 W) A B 25 W 15 W A C 12.5 W 7.5 W A D 6 W 3 W A E 2 W 1 W Ordering details Article numbers BExL 25 d BExL 25 e BExL 15 d BExL 15 e 8 Ω 320 93 00 0 910 320 95 00 0 910 320 97 00 0 910 320 99 00 0 910 16 Ω 320 93 00 0 911 320 95 00 0 911 320 97 00 0 911 320 99 00 0 911 100 V transformer 320 93 00 0 912 320 95 00 0 912 320 97 00 0 912 320 99 00 0 912 Ex Loudspeakers Options / Accessories GOST Further technical information can be found on our website at www.pfannenberg.com 217

EX SIGNALING DEVICES FLASHING SOUNDERS BExCS 110-05D / BExDCS 110-05D Combination devices for visual and acoustic alarms stainless steel protective cage and stainless steel mounting bracket for 360 positioning extremely intensive light refl ection due to 5 joules xenon fl ash 32 different tones incl. DIN tone, UKOOA/PFEER conformant, 2 externally controllable tones (via plus or minus in DC version) (see page 211 for tone table) acoustic and visual signal can be controlled separately synchronised fl ash frequency (1 Hz) or alternating fl ash mode in system operation highly resistant to corrosion and suitable for the toughest environments adjustable volume (except 12 V DC version) fl ashing light is insensitive to vibration, impact and shock r = 56 m max. covering distance IP 67 Protection system + 70 C - 50 C Operating temperature Electrical data BEx(D)CS 110-05D sounder Rated voltage 230 V AC 115 V AC 48 V DC 24 V DC 12 V DC Rated frequency 50 / 60 Hz 50 / 60 Hz Operating range ± 10% ± 10% ± 25% ± 25% ± 25% Nominal current consumption 56 ma 110 ma 130 ma 250 ma 195 ma Electrical data BEx(D)CS 110-05D flashing light Rated voltage 230 V AC 115 V AC 48 V DC 24 V DC 12 V DC Rated frequency 50 / 60 Hz 50 / 60 Hz Operating range ± 10% ± 10% 42 54 V 20 28 V 10 14 V Nominal current consumption 55 ma 140 ma 180 ma 270 ma 750 ma Mechanical data BExCS 110-05D BExDCS 110-05D Explosion protection II 2G Ex d IIB T4-50 C... + 70 C Ta II 2GD Ex d IIB T4 T100 C Category (area of use) 2G (Zone 1) 3G (Zone 2) 2G (Zone 1) / 2D (Zone 21) 3G (Zone 2) / 3D (Zone 22) Certificate of conformity KEMA 03 ATEX 2545 X KEMA 01 ATEX 2223 X Testing body KEMA KEMA Sound pressure level 110 db (A) Sound level reduction - 9 db Flash energy 5 J Flash rate approx. 1 Hz = 60 fl ashes/min. Lens colours clear, yellow, amber, red, green, blue Storage temperature - 50 C + 70 C Relative humidity 90% Protection system according to EN 60529 IP 67 Duty cycle 100% Service life of the flash tube light emission still 70% after 8,000,000 fl ashes lensglass Material housing die-cast aluminium LM6, similar to RAL 3000 (fl ame red) horn ABS self-extinguishing, similar UL 94 VO & 5VA FR ABS, Ex II 2D anti-static ABS, black Connecting terminals 0.5... 4.0 mm 2 Cable entry 2 / 1 x closed, 1 x open (M20), optionally PG13.5 or 1/2 NPT Weight AC 5.0 kg DC 4.8 kg 218 www.pfannenberg.com

Dimensions 368 Ø 181 165 30 30 mounting holes 3 x Ø 7 Ordering details Article numbers BExCS 110-05D Lens colour Rated voltage 230 V AC 115 V AC 24 V DC red 320 74 10 5 000 320 74 15 5 000 320 74 80 5 000 Article numbers for other colours and voltages on request Options / Accessories GOST Visual-audible Ex signaling devices Manufacturer s declaration We hereby declare that the explosion-protected fl ashing light with the type designation BExCS 110-05 D, BExDCS 110-05D has been developed and manufactured in accordance with section 5.1.2 of EN 50014. This declaration is based on compliance with the following regulations and standards: 94/9/EG CE conformity EN 50014 Electrical equipment for areas at risk of explosions General requirements EN 50018 Pressure-resistant encapsulation d EN 50281-1-1 Electrical equipment for use in areas with combustible dust Further technical information can be found on our website at www.pfannenberg.com 219

EX SIGNALING DEVICES LOUDSPEAKER/FLASHING LIGHT COMBINATION BExCL 15-05D Combination device for visual and acoustic alarms extremely intensive light refl ection due to 5 joules xenon fl ash synchronised flash frequency or alternating flash mode in system operation acoustic and visual signal can be controlled separately highly resistant to corrosion and suitable for the toughest environments adjustable volume stainless steel protective cage and stainless steel mounting bracket for 360 positioning r = 79 m max. covering distance IP 67 Protection system + 70 C - 50 C Operating temperature Electrical data BExCL 15-05D Rated voltage 230 V AC 115 V AC 48 V DC 24 V DC 12 V DC Rated frequency 50 / 60 Hz 50 / 60 Hz Operating range ± 10% ± 10% 42 54 V 20 28 V 10 14 V Nominal current consumption 55 ma 140 ma 180 ma 270 ma 750 ma Mechanical data BExCL 15-05D Explosion protection II 2G Ex d IIB T4 Category (area of use) 2G (Zone 1) / 3G (Zone 2) Certificate of conformity KEMA 03 ATEX 2545 Testing bodykema Sound pressure level 113 db (A) ± 3 db (A) @ 15 W Rated power sine wave 15 W Transformer type 100 V power 15 W / 7.5 W / 3 W / 1 W taps (Z = 666.87 Ω / 1.34 kω / 3.34 kω / 10 kω) Impedance type 8 Ω or 16 Ω Dispersion 120 @ 1 khz / 32 @ 4 khz Frequency range 400 Hz 8,000 Hz Flash energy Flash rate Lens colours 5 J approx. 1 Hz clear, yellow, amber, red, green, blue Temperature class T IIB: T4 @ - 50 C... + 70 C Ta Storage temperature - 50 C + 70 C Protection system according to EN 60529 IP 67 Duty cycle 100% Service life of the flash tube light emission still 70% after 8,000,000 fl ashes Material lensglass housing die-cast aluminium LM6, RAL 3000 (fl ame red) horn ABS self-extinguishing, similar UL 94 VO & 5VA FR ABS, Ex II 2D anti-static ABS Connecting terminals 0.5... 4.0 mm 2 Cable entry 2 / 1 x closed, 1 x open (M20), optionally PG13.5 or 1/2 NPT Weight 5 kg 220 www.pfannenberg.com

Dimensions 368 Ø 181 165 30 30 mounting holes 3 x Ø 7 Ordering details Article numbers BExCL 15-05D Lens colour Version 230 V AC 24 V DC red 8 Ω 320 91 10 5 910 320 91 80 5 910 red 16 Ω 320 91 10 5 911 320 91 80 5 911 red 100 V transformer 320 91 10 5 912 320 91 80 5 912 Article numbers for other colours and voltages on request Options / Accessories GOST Visual-audible Ex signaling devices Manufacturer s declaration We hereby declare that the explosion-protected means of alarm with the type designation BExCL 150-05 D has been developed and manufactured in accordance with section 5.1.2 of EN 50014. This declaration is based on compliance with the following regulations and standards: 94/9/EG CE conformity EN 50014 Electrical equipment for areas at risk of explosions General requirements EN 50018 Pressure-resistant encapsulation d EN 50281-1-1 Electrical equipment for use in areas with combustible dust Further technical information can be found on our website at www.pfannenberg.com 221

EX SIGNALING DEVICES IS-MINI LED BLINKING SOUNDER IS-mC1 Very economical visual and acoustic alarm certifi ed for use in Ex-Zones 0, 1 and 2! compact design with a diameter of just 88 mm alarm operated via certifi ed zener barriers or galvanic isolators 49 loud tones at 100 db (A); super-bright LEDs in red, green, blue and yellow/amber for all applications volume control can be operated as combination unit or separately very well suited for fi re alarm systems and direct control due to low power consumption self-synchronising sounder for clear tone perception 2 different externally controllable tones See pages 224 and 225 for suitable zener barriers r = 18 m max. covering distance IP 65 Protection system + 60 C - 40 C Operating temperature Electrical data IS-mC1 Rated voltage 24 V DC Operating range 16 28 V Nominal current consumption 48 ma (typical for connection to 24 V DC via 28 V / 300 Ω zener barrier) Power must be connected via a zener barrier (max. 28 V DC, 93 ma DC, 0.66 W) or a galvanic isolator, specifi ed by the system certifi cate (see page 225) Mechanical data IS-mC1 Type of protection ia inherently safe Explosion protection II 1G Ex ia IIC T4-40 C... + 60 C Ta Category (area of use) 1G (Zone 0) / 2G (Zone 1) / 3G (Zone 2) Certificate / Testing body SIRA 05 ATEX2084 X / SIRA Sound pressure level 100 db (A) Sound level reduction by - 20 db Flash rate can be set to 2 Hz or 1 Hz Lens colour clear, with red, yellow/amber, blue or green LEDs Storage temperature - 40 C + 70 C Relative humidity 90% Protection system according to EN 60529 IP 65 Duty cycle 100% Material housing ABS, self-extinguishing UL94VO & 5VA, similar to RAL 3000 (fl ame red) lenspolycarbonate (PC) Connecting terminals 0.5 2.5 mm 2 Cable entry 2 x M20 (knock-outs prepared) Weight 280 g Dimensions Ø 88.7 116 M20 95 85.5 A/F M20 222 www.pfannenberg.com

Tone table Stage Tone Description - Frequency 2 3 1 Continuous tone 340 Hz 2 5 1000 Hz Alternating tone, UK BS5839-1 0.25 s EN54-3 2 17 5 (fi re alarm, railway crossing) 0.25 s 3 Slow whoop, evacuation alarm Netherlands NEN 2575 2 5 4Sweeping (fast) 6 5 5Continuous tone 2400 Hz 3 20 6Sweeping 7 5 7Sweeping (fast) 10 5 8Sweeping 2 5 9 Sawtooth, DIN tone 33404-3 Germany (emergency signal), PFEER PTAP 800 Hz 1200 Hz 500 Hz 15 2 10Alternating tone 7 5 11Interrupted tone 2 5 12Alternating tone 4 5 13Interrupted tone 15 5 14Interrupted tone 4 5 15Continuous tone 800 Hz 2 5 16Interrupted tone 18 5 3.5 s 1000 Hz 0.5 s 800 Hz 10 ms 2900 Hz 10 ms 2400 Hz 70 ms 2900 Hz 10 ms 2400 Hz 10 ms 1200 Hz 3 s 70 ms EN54-3 500 Hz 3 s 1200 Hz 1 s EN54-3 500 Hz 2900 Hz 20 ms 2400 Hz 20 ms 1000 Hz 10 ms 10 ms 1000 Hz 0.875 s 800 Hz 0.875 s 2400 Hz 800 Hz 660 Hz 0.25 s 10 ms 10 ms 1 s 150 ms 150 ms EN54-3 Tone Description - Frequency Stage 2 3 25Sweeping 29 5 26Simulated bell 2 15 27Continuous tone 800 Hz 26 5 28Continuous tone 440 Hz 2 5 29 Sweeping (fast), UK BS5839-1 7 5 30 Continuous tone 300 Hz 2 5 31Sweeping 26 5 32 2-tone bell sound 26 15 33 Interrupted tone 2 5 34 Alternating tone, Singapore 38 45 420 Hz 35 Interrupted tone Australian alert 36 5 36 Sweeping, IMO 3d, Germany KTA3901 evacuation alarm 35 5 37 Continuous tone 1000 Hz 9 45 38 Continuous tone 2000 Hz 34 45 39 Interrupted tone 23 17 40 Alternating tone, France NFS 32-001 (fi re alarm) 2900 Hz 2400 Hz 0.5 s 1450 Hz 1000 Hz 800 Hz 70 ms 1200 Hz 31 27 41Motor siren 2 5 0.5 s 70 ms 660 Hz 10 ms 800 Hz 10 ms 650 Hz 2 s 745 Hz 10 ms 10 ms 2000 Hz 0.5 s 1000 Hz 0.5 s 800 Hz 554 Hz 0.625 s 0.625 s 1200 Hz 1 s 500 Hz 1 s 0.1 s 440 Hz 1200 Hz 0,25 s 0,25 s 0.25 s 0.69 ms 0.4 s 1 s EN54-3 const. 17 Alternating tone, France NFS 32-001 (fi re alarm) 554 Hz 440 Hz 0.1 s 0.4 s EN54-3 2 27 800 Hz const. 42Motor siren 2 5 18 Interrupted tone, Sweden SS031711 (air raid warning) 2 5 19 Sweeping, France NFC48-265 2 5 20 Continuous tone, Sweden SS031711 (all-clear signal) 660 Hz 1.8 s 1.8 s 1600 Hz 1400 Hz 1 s 0.5 s 660 Hz 554 Hz 2 5 21Alternating tone 2 5 440 Hz 544 Hz 22Interrupted tone 2 5 800 Hz 10 ms 10 ms 0.875 s 0.875 s 23Interrupted tone 6 5 20 ms 20 ms 1000 Hz 0.5 s 24 Sweeping (medium), UK BS5839-1 29 5 800 Hz 0.5 s 43 Continuous tone, PFEER gasalarm 1200 Hz 2 5 44Motor siren 2 5 45 46 47 48 49 Interrupted tone, PFEER (general alarm) Sawtooth, DIN tone 33404-3 Germany (emergency signal), PFEER PTAP Interrupted tone, PFEER (general alarm) Interrupted tone, Australia AS2220, AS1610, AS1670 Sweeping, IMO 3d, Germany KTA3901 evacuation alarm 2400 Hz 1000 Hz 1200 Hz 500 Hz 1000 Hz 420 Hz const. 1 s 1 s 1 s EN54-3 1 s 1 s 0.625 s 0.625 s 1200 Hz 1 s 500 Hz 1 s 38 34 47 37 46 37 49 5 26 37 Visual-audible Ex signaling devices Ordering details Article numbers IS-mC1 Colour LED Rated voltage 24 V DC yellow/amber 320 35 80 4 000 red 320 35 80 5 000 green 320 35 80 6 000 blue 320 35 80 7 000 Further technical information can be found on our website at www.pfannenberg.com 223

EX SIGNALING DEVICES ACCESSORIES ZENER BARRIERS Combination possibilities: Zener barrier, IS-A105N sounder and IS-Mini series alarm Non Ex area Ex area / Ex-Zone 0, 1 or 2 Categories 1G, 2G or 3G 1 st stage 1 st stage 24 V DC + VE Z 728 IS-A105N 24 V DC + VE Z 728 Stage 2 1 st -3 rd stage IS-A105N Stage 3 2 nd stage Z 786 3 rd stage Stage 1 24 V DC (pole reversal) + + Z 928 AC R IS-A105N R = monitoring resistor = parallel to input Z 728 24 V DC + IS-mB1 Z 728 24 V DC + IS-mA1 Z 728 24 V DC + IS-mC1 224 www.pfannenberg.com

Technical data for Zener barriers Type Version V Ω Z 728 Zener barrier + Ve BAS 01 ATEX 7005 Rated data Ex characteristic values for (Eex ia) IIC Technical data U Z (V) R min (Ω) I k (I 0 ) (ma) P max (W) C max (µf) L max (mh) L/R Ratio max. longitudinal resistance (Ω) U in at 10 µa (V) U in max. (V) rated safety current (ma) 28 300 28 301 93 0.65 0.083 3.05 56 327 26.5 28 50 Z 928 Zener barrier AC BAS 01 ATEX 7005 28 300 28 301 93 0.65 0.083 3.05 56 327 26 27.6 50 Z 786 Diode barrier BAS 01 ATEX 7005 28 Diode A1 A2 B 28 28 28 0.083 0.083 0.083 36 + 0.9 V 36 + 0.9 V 26.5 26.5 28 28 50 50 Note: A1 and A2 - separate channels, B - two channels connected in parallel with ground connection Mechanical data Design terminal housing made of makrolon, fl ammability class UL 94 V-0 Height x Width x Depth mm 110 x 12.5 x 115 Mounting snap fi tting to 35 mm DIN rail conforming to DIN EN 50022 Connection self-opening apparatus terminals; max. wire cross-section 2 x 2.5mm 2 Ambient temperature - 20 C + 60 C Ordering details Article numbers Z 728 Z 928 Z 786 381 09 80 0 000 381 09 30 0 000 381 09 80 0 001 Block circuit diagrams Non-Ex-area Connections 8 Ex-area Connections Z 728 1 7 2 + VE type Z 928 8 1 7 x 3 x 3 2 Accessories Z 786 8 1 7 x 3 2 6 5 x 3 3 4 Further technical information can be found on our website at www.pfannenberg.com 225

EX SIGNALING DEVICES CONNECTION DIAGRAMS Quadro F12-3G/3D ATEX AC DC for supplying additional fl ashing lights supply voltage Quadro-LED Flex-3G/3D operating mode control BExBG 15 / BExBG 10 / BExBG 05 EEx e internal potential equalisation internal earth terminal 24 V DC 24 V DC 2 x M20 cable entries BExBG 05 EEx d BExBG15 / BExBG 10 EEx d connecting terminals connecting terminals multi-pin connector for alternating fl ash mode multi-pin connector for alternating fl ash mode BExBG L1D AC BExBG L1D DC operation mode selection connecting terminals operation mode selection control stage S2 and S3 control stage S2 and S3 226 www.pfannenberg.com

DS 5 3G/3D / DS 10 3G/3D AC operating voltage connection AC optional for DS 5: volume control - 20 db (A) DS 5 3G/3D / DS 10 3G/3D DC soft start module and cable monitoring DC tone selection switch tone selection switch options TAS / TAV: external tone selection stage 2, 3 and 4 115 V / 230 V AC cable connection 12 / 24 / 48 V DC 24 V AC for the supply of additional sounders; max. 10 of type DS 10 or max. 15 of type DS 5 IS-A105N tone selection switch volume control operating voltage connection IS-mA1 IS-mC1 Connection diagrams tone selection switch tone selection switch blinking rate setting seal seal connecting terminals for light volume control volume control connecting terminals connecting terminals for sounder Further technical information can be found on our website at www.pfannenberg.com 227

EX SIGNALING DEVICES BExS 110d AC BExS 110d DC volume control control stage S2 and S3 volume control multi-pin connector DC connections AC connections code switch code switch BExS 120d AC BExS 120d DC volume control control stage S2 and S3 volume control DC connections AC connections code switch code switch multi-pin connector BExS 110e DC BExS 120e DC multi-pin connector (only DC devices) volume control connection for terminal resistor or terminal diode volume control connection for terminal resistor or terminal diode code switch multi-pin connector (only DC devices) code switch 228 www.pfannenberg.com

BExCS 110-05D sounder AC BExCS 110-05D sounder DC volume control control stage S2 and S3 volume control multi-pin connector DC connections AC connections code switch code switch internal connecting terminals for sounder PCB (simultaneous operation) BExCS 110-05D flashing light AC BExCS 110-05D flashing light DC internal connecting terminals for sounder PCB (simultaneous operation) AC connections multi-pin connector for alternating fl ash mode DC connections multi-pin connector for alternating fl ash mode BExCL 15-05D flashing light AC 8 Ω / 16 Ω BExCL 15-05D loudspeaker AC connections multi-pin connector for alternating fl ash mode Connection diagrams DC 100 V DC connections multi-pin connector for alternating fl ash mode Further technical information can be found on our website at www.pfannenberg.com 229

THERMAL MANAGEMENT 230 www.pfannenberg.com

Pfannenberg also offers, in addition to the area of signaling technology, a very comprehensive product portfolio for the thermal management of electrical enclosures and process cooling. Pfannenberg is one of the few manufacturers worldwide which offers complete competence developed in-house from fi lterfans, cooling units and chillers to heaters and thermostats. You can also profi t here from comprehensive know-how and several years application experience in various industrial areas. You can fi nd the entire portfolio of Pfannenberg thermal management and process cooling of electrical enclosures and chillers on www.pfannenberg.com. Or just order your complimentary copy of the whole catalogue Thermal management of electrical enclosures on +49 40 734 12 156. The following chapter shows you a selection of Pfannenberg s thermal management portfolio cut-out compatible, energy efficient and service-friendly. EFFICIENT COOLING AND HEATING COOLING UNITS, FILTERFANS, HEAT EXCHANGERS, HEATERS, THERMOSTATS, HYGROSTATS AND CHILLERS Thermal Management Further technical information can be found on our website at www.pfannenberg.com 231

THERMAL MANAGEMENT CUT-OUT COMPATIBILITY Components in the enclosure are often updated and the requirements to thermal management change. An air/air heat exchanger which was previously the optimal solution is not suitable any more. The exchange with an active εcool cooling unit or an air/water heat exchanger can be carried out easily and without problems, because the units have the same cut-out dimensions. Thus, the process stability is also ensured after extensive modifi cations. Cut-out Cooling unit Air/water heat exchanger Air/air heat exchanger Size 1 DTx 9041 PWx 6105 PWx 6052 PAx 6043 Size 2 DTx 9341C DTx 9141 PWx 6302C PWx 6152 PAx 6133 PAx 6103 PAx 6073 Size 3 DTx 6801 DTx 6501 DTx 6401 DTx 6301 DTx 6201 PWx 6502 PWx 6302 PAx 6203 PAx 6173 Cooling unit Air/water heat exchanger Air/air heat exchanger Cut-out outer mounting Size 1 Size 2 Size 3 Cut-out recessed mounting Size 1 Size 2 Size 3 A 472 mm 662 mm 700 mm B 285 mm 320 mm 315 mm K 577 mm 900 mm 1510 mm L 350 mm 380 mm 450 mm C 272 mm 220 mm THE ADVANTAGES AT A GLANCE Flexible adjustment to cooling requirements according to ambient conditions Possibility of late decision for the thermal management concept Reduced construction efforts only 3 cut-out sizes Reduced number of cabinet variations Interchangeable thermal management concepts without mechanical reworking 232 www.pfannenberg.com

OVERVIEW OF COOLING UNITS Type Cooling capacity* Rated voltage Cut-out dimensions (height x width)... FOR PARTIALLY RECESSED MOUNTING IN THE DOOR OR SIDE εcool DTI 6801 4000 W 400 V 3~ εcool DTI 6501 2500 W 400 V 3~ εcool DTI 6401 2000 W 230 V / 400 V 3~ 1510 x 450 mm εcool DTI 6301 1500 W 115 V / 230 V / 400 V 2~ εcool DTI 6201 1000 W 115 V / 230 V / 400 V 2~ DTI 9341C 1500 W 115 V / 230 V / 400 V 2~ DTI 9141 950 W 115 V / 230 V / 400 V 2~ 900 x 380 mm DTI 9041 870 W 115 V / 230 V / 400 V 2~ 577 x 350 mm DTI 9031 510 W 115 V / 230 V / 400 V 2~ 495 x 265 mm DTI 9021 320 W 115 V / 230 V 289 x 304 mm DTFI 9021 320 W 115 V / 230 V / 400 V 2~ 291 x 291 mm... FOR OUTER MOUNTING ON THE DOOR OR SIDE εcool DTS 6801 4000 W 400 V 3~ εcool DTS 6501 2500 W 400 V 3~ εcool DTS 6401 2000 W 230 V / 400 V 3~ 700 x 315 / 220 x 315 mm εcool DTS 6301 1500 W 115 V / 230 V / 400 V 2~ εcool DTS 6201 1000 W 115 V / 230 V / 400 V 2~ DTS 9341C 1500 W 115 V / 230 V / 400 V 2~ DTS 9141 950 W 115 V / 230 V / 400 V 2~ 662 x 320 mm DTS 9041 870 W 115 V / 230 V / 400 V 2~ 472 x 285/272 mm DTS 9031 510 W 115 V / 230 V / 400 V 2~ 422 x 215 mm DTS 9011H 300 W 230 V 300 x 495 x 140 mm Type Cooling capacity* Rated voltage Cut-out dimensions (depth x width)... FOR TOP MOUNTING εcool DTT 6801 4000 W 400 V 3~ εcool DTT 6601 3000 W 400 V 3~ εcool DTT 6401 2000 W 115 V / 230 V / 400 V 2~ εcool DTT 6301 1500 W 115 V / 230 V / 400 V 2~ 392 x 692 mm 390 x 490 mm εcool DTT 6201 1000 W 115 V / 230 V / 400 V 2~ 260 x 475 mm εcool DTT 6101 500 W 115 V / 230 V * (L35/L35) in accordance with EN 14511: at +35 C ambient temperature and +35 C temperature inside enclosure Thermal Management Further technical information can be found on our website at www.pfannenberg.com 233

THERMAL MANAGEMENT OVERVIEW OF AIR/WATER HEAT EXCHANGERS Type Cooling capacity Rated voltage Cut-out dimensions (height x width)... FOR PARTIALLY RECESSED MOUNTING IN THE DOOR OR SIDE εcool PWI 6502 5000 W 115 V / 230 V / 400 V εcool PWI 6302 3000 W 115 V / 230 V / 400 V εcool PWI 6302C 4000 W 115 V / 230 V / 400 V εcool PWI 6152 1500 W 115 V / 230 V / 400 V εcool PWI 6102 1000 W 115 V / 230 V εcool PWI 6052 500 W 115 V / 230 V 1510 x 450 mm 900 x 380 mm 577 x 350 mm... FOR OUTER MOUNTING ON THE DOOR OR SIDE εcool PWS 6502 5000 W 115 V / 230 V / 400 V εcool PWS 6302 3000 W 115 V / 230 V / 400 V εcool PWS 6302C 4000 W 115 V / 230 V / 400 V εcool PWS 6152 1500 W 115 V / 230 V / 400 V εcool PWS 6102 1000 W 115 V / 230 V εcool PWS 6052 500 W 115 V / 230 V 700 x 315 / 220 x 315 mm 662 x 320 mm 472 x 285/272 mm OVERVIEW OF AIR/AIR HEAT EXCHANGERS Type Specific cooling capacity Rated voltage Cut-out dimensions (height x width)... FOR PARTIALLY RECESSED MOUNTING IN THE DOOR OR SIDE εcool PAI 6203 100 W/K 115 V / 230 V εcool PAI 6173 85 W/K 115 V / 230 V 1510 x 450 mm εcool PAI 6133 65 W/K 115 V / 230 V εcool PAI 6103 50 W/K 115 V / 230 V 900 x 380 mm εcool PAI 6073 35 W/K 115 V / 230 V εcool PAI 6043 20 W/K 115 V / 230 V 577 x 350 mm... FOR OUTER MOUNTING ON THE DOOR OR SIDE εcool PAS 6203 100 W/K 115 V / 230 V εcool PAS 6173 85 W/K 115 V / 230 V 700 x 315 / 220 x 315 mm εcool PAS 6133 65 W/K 115 V / 230 V εcool PAS 6103 50 W/K 115 V / 230 V 662 x 320 mm εcool PAS 6073 35 W/K 115 V / 230 V εcool PAS 6043 20 W/K 115 V / 230 V 472 x 285/272 mm 234 www.pfannenberg.com

OVERVIEW OF CHILLERS Type Cooling capacity Rated voltage Dimensions (height x width x depth) εcool CC CHILLER CC 6601 6500 W 400 V / 460 V 3 ~ CC 6501 5000 W 400 V / 460 V 3 ~ 984 x 601 x 670 mm CC 6401 3500 W 400 V / 460 V 3 ~ CC 6301 2400 W 115 V / 230 V CC 6201 1700 W 115 V / 230 V 626 x 600 x 480 mm CC 6101 1100 W 115 V / 230 V EB CHILLER EB 400 (Wasser) 40000 W 400 V / 460 V 3 ~ EB 400 (Öl) 40000 W 400 V / 460 V 3 ~ EB 190 (Wasser) 19000 W 400 V / 460 V 3 ~ EB 190 (Öl) 19000 W 400 V / 460 V 3 ~ EB 75 (Wasser) 7500 W 400 V / 460 V 3 ~ EB 75 (Öl) 7500 W 400 V / 460 V 3 ~ 1410 x 1680 x 790 mm 1410 x 1230 x 790 mm 1337 x 705 x 750 mm OVERVIEW OF FILTERFANS 4.0 Type Airflow rate 1 IP 54 / IP 55 Rated voltage Cut-out dimensions (height x width) 2 εcool PF FILTERFANS * PF 11.000 25 / - m³/h 92 x 92 mm PF 22.000 61 / 56 m³/h 125 x 125 mm PF 32.000 110 / 100 m³/h 115 V / 230 V AC 12 V / 24 V / 48 V DC 177 x 177 mm PF 42.500 156 / 145 m³/h 223 x 223 mm PF 43.000 256 / 233 m³/h PF 65.000 480 / 505 m³/h 115 V / 230 V AC PF 66.000 640 / 770 m³/h 400/460 V 3 ~ PF 67.000 845 / 925 m³/h 115 V / 230 V AC 291 x 291 mm εcool PFA EXHAUST FILTERS * PFA 10.000 PFA 20.000 PFA 30.000 PFA 40.000 PFA 60.000 * EMC versions also available 92 x 92 mm 125 x 125 mm 177 x 177 mm 223 x 223 mm 291 x 291 mm εcool PTF FILTERFANS FOR TOP MOUNTING PTF 60.500 500 / 350 m³/h PTF 60.700 700 / 550 m³/h 115 V / 230 V AC 291 x 291 mm PTF 61.000 1000 / 750 m³/h Thermal Management εcool PTFA EXHAUST FILTERS FOR TOP MOUNTING PTFA 60.000 291 x 291 mm 1 free-blowing 2 for material thicknesses up to 2 mm Further technical information can be found on our website at www.pfannenberg.com 235

THERMAL MANAGEMENT OVERVIEW OF HEATERS Type Heating performance Rated voltage Dimensions (height x width x depth) FLH RADIANT HEATERS FLH 010 10 W 110 V - 250 V AC 100 x 70 x 50 mm FLH 015 15 W 110 V - 250 V AC 100 x 70 x 50 mm FLH 030 30 W 110 V - 250 V AC 100 x 70 x 50 mm FLH 045 45 W 110 V - 250 V AC 100 x 70 x 50 mm FLH 060 60 W 110 V - 250 V AC 175 x 70 x 50 mm FLH 075 75 W 110 V - 250 V AC 175 x 70 x 50 mm FLH 100 100 W 110 V - 250 V AC 175 x 70 x 50 mm FLH 150 150 W 110 V - 250 V AC 250 x 70 x 50 mm FLH FAN HEATERS FLH 250 250 W 115 V / 230 V AC 186,5 x 85 x 104 mm FLH 400 400 W 115 V / 230 V AC 226,5 x 85 x 104 mm FLH-T FAN HEATERS WITH INTEGRATED THERMOSTAT FLH-T 250 250 W 115 V / 230 V AC 100 x 150 x 164 mm FLH-T 400 400 W 115 V / 230 V AC 100 x 150 x 164 mm FLH-T 600 600 W 115 V / 230 V AC 100 x 150 x 164 mm FLH-T 800 800 W 115 V / 230 V AC 100 x 150 x 164 mm FLH-T 1000 1000 W 115 V / 230 V AC 100 x 150 x 164 mm PFH COMPACT FAN HEATERS PFH 200 200 W 115 V / 230 V AC 142 x 88 x 133 mm PFH 300 300 W 115 V / 230 V AC 142 x 88 x 133 mm PFH 400 400 W 115 V / 230 V AC 142 x 88 x 133 mm PFH 500 500 W 115 V / 230 V AC 142 x 88 x 133 mm PFH 650 650 W 115 V / 230 V AC 142 x 88 x 133 mm PFH 800 800 W 115 V / 230 V AC 142 x 88 x 133 mm PFH 1000 1000 W 115 V / 230 V AC 142 x 88 x 133 mm PFH 1200 1200 W 115 V / 230 V AC 142 x 88 x 133 mm 236 www.pfannenberg.com

OVERVIEW OF THERMOSTATS AND HYGROSTATS Type Operating temperature range Type of contact Switching point tolerance Dimensions (HxWxD) FLZ THERMOSTATS AND HYGROSTATS FLZ 510 Thermostat changeover ± 3 59.5 x 37 x 47.5 mm FLZ 520 Thermostat - 40 + 80 C / - 40 + 176 F N.C. ± 4 72 x 40 x 36 mm FLZ 530 Thermostat N.O. ± 4 72 x 40 x 36 mm FLZ 541 Thermostat N.C. / N.O. ± 4 80.5 x 59 x 38 mm FLZ 542 Thermostat - 40 + 80 C / - 40 + 176 F N.C. / N.C. ± 4 80.5 x 59 x 38 mm FLZ 543 Thermostat N.O. / N.O. ± 4 80.5 x 59 x 38 mm FLZ 600 Hygrostat FLZ 610 Hygrostat 0 + 60 C / + 30 + 140 F - 20 + 60 C / - 4 + 140 F changeover approx. 5% 64 x 37 x 46 mm changeover/relay approx. 2 K ± 1 K approx. 4% R.H. ± 1% 80.5 x 59 x 38 mm OVERVIEW OF ENCLOSURE LIGHTING SYSTEMS Type Light intensity Rated voltage Type of connection Additional connections Dimensions (HxWxD) STANDARD LAMP SYSTEMS PLS 008 Mini 450 Lm 230 V AC mains cable with 430 x 120 x 50 mm PLS 013 Mini 640 Lm 230 V AC plug included 320 x 95 x 50 mm cable (1.5 m) PLS 014 Mini 700 Lm 230 V AC GST 18/3 plug GST 18/3 socket door contact integrated door end switch 320 x 95 x 50 mm Thermal Management Further technical information can be found on our website at www.pfannenberg.com 237

ART ILLUMINATION 238 www.pfannenberg.com

Illumination is naturally also technology. In its purest form, however, it is much more. Namely art. Or, to put it better: a real philosophy, because with light, you can take your building into a completely new dimension. That is what makes perfect illumination an ideal image tool. Present your building or structure in the right light. You can see for yourself how that looks in Paris, for example, where we illuminated a famous tower by a certain Gustave Eiffel, or in St. Petersburg, where the TV Tower and Trinity Bridge (Troitskiy-Most) are lit up by 9,500 Pfannenberg fl ashing lights. THE FOURTH DIMENSION FOR YOUR STRUCTURE! BENEFIT FROM OUR KNOW-HOW IN THE FIELD OF LIGHT ARCHITECTURE Further technical information can be found on our website at www.pfannenberg.com 239 Art Illumination

ART ILLUMINATION ART ILLUMINATION A COMPLETELY DIFFERENT SIDE OF PFANNENBERG: ART ILLUMINATION. The beauty of the application and the durability and sturdiness of Pfannenberg fl ashing lights are the driving forces here. Let yourself be captivated by a few selected examples of Pfannenberg s artistic side. Quadro R-ST In June 2008, St. Petersburg became the scene of a fantastic art illumination installation. The TV Tower and the Trinity Bridge were illuminated as part of the International Economic Forum. The project, which was based on the unique illumination of the Eiffel Tower in Paris, was carried out by a local company under the auspices of the city authorities. 9,500 Pfannenberg Quadro R-ST fl ashing lights were used for the project, selected because of their sturdy design that guarantees a long service life under adverse conditions. St. Petersburg, Russia TV Tower and Trinity Bridge Quadro R Pfannenberg put the Eiffel Tower back in the spotlight on 21 June 2003. Millions of people all over the world have admired the fl ashing lights that illuminate one of the most famous landmarks in the world. 20,000 fl ashing lights, specially manufactured by Pfannenberg GmbH, were installed by experienced mountaineers in order to light up the Eiffel Tower. Each light has a service life of at least 10 years and can light up over 10 million times during that time. Thanks to their special design, they withstand summer and winter, storm and hail and illuminate the Eiffel Tower daily between 7 pm and midnight every hour on the hour for 10 minutes, as well as on special occasions. Paris, France Eiffel Tower DO YOU REQUIRE FURTHER INFORMATION? Just call us about any project: your ideas and our experience are sure to lead to great success! Global Product Management: +49 40 73412-226 or -223 240 www.pfannenberg.com

PSL 060 At the Expo 2000, the façade of the French Pavilion was turned into a spectacular eye-catcher. Etienne Jules Meray s photo The Walking Man, taken in 1880, was recreated as a large, moving light construction in keeping with the exhibition s slogan: Transport, Mobility and Movement. The 26 steps of the movement were illuminated in quick succession by Pfannenberg flashing lights. Like in a film, the lights ran along the 100 metre long walkway in 2 seconds and brought the man to life, day and night. Hanover, Germany Expo 2000 AB-PN Pfannenberg s extremely bright and extremely strong fl ashing lights were used to illuminate the Pont de Normandie. The frequencies of the fl ashing lights can be programmed in various stages and the light sequences adjust themselves to the level of traffi c on the bridge: a lot of traffi c fast sequences, little traffi c slow sequences. Due to the varying light sequences, the light installation has become a real attraction that draws in and captivates tourists. Le Havre - Honfl eur, France Pont de Normandie Quadro R-ST In honour of the Sino-European Economic Conference in Hamburg in 2004, the organisers wanted to create a special accent and had the Council House lit up in blue. As the icing on the cake, the tower was lit by Pfannenberg Eiffel Tower fl ashing lights, thus captivating the observers with the famous Champagne sparkle. Many citizens and visitors described the project, which could be seen from afar, as innovative and, as the light artist Michael Batz, who arranged the lights, said: on a par with large cities such as Paris or New York. Further technical information can be found on our website at www.pfannenberg.com Hamburg, Germany Council House 241 Art Illumination

ART ILLUMINATION FLASHING LIGHTS 10 J Quadro R / Quadro R-ST Quadro R art illumination inside and outside buildings, even under the toughest of conditions with instant sparkling effect Quadro R-ST (additional) equipped with industrial plug connectors for simple mounting one plug connector each for input and output, thus the devices can be connected in a row IP 66 IP 67 IK 08 + 55 C - 40 C Protection system Protection system Impact-proof housing Operating temperature Electrical data Quadro R Quadro R-ST Rated voltage 230 V AC 230 V AC Rated frequency 50 / 60 Hz 50 / 60 Hz Operating range 195 V 253 V 195 V 253 V Nominal current consumption 85 ma 85 ma Mechanical data Quadro R Quadro R-ST Flash rate 22 28 fl ashes/min. Flash energy 10 J Light intensity (DIN 5037) 1 124 cd Lens colours clear, white, yellow, amber, red, green, blue Operating temperature - 40 C... + 55 C Storage temperature - 40 C... + 70 C Relative humidity 100% Protection system according to EN 60529 IP 66, IP 67, mounting arbitrary Impact resistance as per EN 50102 IK 08 Protection class II Duty cycle 100% Service life of the flash tube light emission still 70% after 10,000,000 fl ashes Material lens polycarbonate (PC) housing polycarbonate (PC), RAL 7035 Type of connection screw clamps 2.5 mm 2 2 x plug connectors (input/output) Cable entry 2 x M20 Mounting external lugs 113 x 153 mm M5 or 127.1 x 127.1 mm M5 internal holes 113 x 113 mm Weight 600 g 1 with a clear lens 242 www.pfannenberg.com

Dimensions Quadro R 113 mounting holes Ø 4.5 174 133.5 134 80 40 25 113 130 80 mounting screws e.g. 4 x M4 x 20 130 blanking plug M20 x 1.5 cable connection M20 x 1.5 Quadro R-ST 130 Ordering details Article numbers Quadro R Quadro R-ST Lens colour Rated voltage 230 V AC 230 V AC clear 291 23 10 1 005 291 24 10 1 000 Article numbers for other colours on request Options / Accessories GOST Further technical information can be found on our website at www.pfannenberg.com 243 Art Illumination

ART ILLUMINATION FLASHING LIGHT 10 J Quadro A-DMX DMX-Controller for the individual controlling of each individual light in the system by means of a DMX-Bus system can be directly controlled by means of the standard DMX-Master rugged plug connectors for power supply and DMX-Bus (inlet and outlet) IP 66 IP 67 IK 08 + 60 C - 30 C I lim t Protection system Protection system Impact-proof housing Operating temperature Electrical data Rated voltage Rated frequency Operating range Nominal current consumption Initial current limited to Quadro A-DMX 230 V AC 50 / 60 Hz 195 V 253 V 280 ma @ 1 Hz < 1 A Mechanical data Quadro A-DMX Flash rate 2 Hz Flash energy 10 J Light intensity (DIN 5037) 1 124 cd Lens colours clear, white, yellow, amber, red, green, blue Operating temperature - 30 C... + 60 C Storage temperature - 40 C... + 70 C Relative humidity 100% Protection system according to EN 60529 IP 66, IP 67, mounting arbitrary Impact resistance as per EN 50102 IK 08 Protection class II Duty cycle 100% Service life of the flash tube light emission still 70% after 10,000,000 fl ashes Material lens polycarbonate (PC) housing polycarbonate (PC), RAL 7035 Type of connection 2 x plug connectors for operation voltage 2 x plug connectors for Bus-connection Cable entry 2 x M20 Mounting external lugs 113 x 153 mm M5 or 127.1 x 127.1 mm M5 internal holes 113 x 113 mm Weight 600 g 1 with a clear lens 244 www.pfannenberg.com

Dimensions 25 130 134 242.5 DMX-output DMX-input output power supply 242.5 input power supply 130.1 Ordering details Article numbers Quadro A-DMX Lens colour Rated voltage 230 V AC clear 291 25 10 1 000 Article numbers for other colours on request Options / Accessories GOST Further technical information can be found on our website at www.pfannenberg.com 245 Art Illumination

CONTACTS PFANNENBERG WORLDWIDE EXPERTISE IN THERMAL MANAGEMENT AND SIGNALING TECHNOLOGY Sales + Manufacturing Sales Sales Partner Pfannenberg Group Holding GmbH Werner-Witt-Straße 1 21035 Hamburg Phone: +49 40 7 34 12-0 Telefax: +49 40 7 34 12-101 info@pfannenberg.com Factories: Pfannenberg GmbH Werner-Witt-Straße 1 21035 Hamburg Germany Pfannenberg Inc. 68 Ward Road Lancaster, N.Y. 14086 USA Pfannenberg Italia s.r.l. Via la Bionda, 13 43036 Fidenza (PR) Italy Pfannenberg (Suzhou) Pte Ltd 5-1-D, No. 333 Xingpu Rd., SIP Suzhou 215021, Jiangsu P.R. China 246 www.pfannenberg.com