Leverage Building Energy Diversity in High Efficiency HVAC Design

Similar documents
Applying VRF? Don t Overlook Standard 15

Applying VRF? Don t Overlook Standard 15

NET ENERGY WATER LOOPS A clear path to net zero energy buildings

Variable refrigerant flow (VRF) systems

Variable Refrigerant Flow (VRF) Systems

GEOTHERMAL DESIGN GUIDE

ENGINEERING. Edition No. 13 October 2002

By Thomas H. Durkin, P.E., Member ASHRAE, and James B. (Burt) Rishel, P.E., Fellow/Life Member ASHRAE

COMMERCIAL HVAC EQUIPMENT Indoor Self-Contained Units

COMMERCIAL HVAC SYSTEMS Water Source Heat Pump Systems

Performance Comparison of Hydronic Secondary Loop Heat Pump and Conventional Air-Source Heat Pump ABSTRACT 1. INTRODUCTION

FACT SHEET 9 Large Air-Conditioning (air-to-air)

FACT SHEET 9 Large Air-Conditioning (air-to-air)

Applications of Thermodynamics: Heat Pumps and Refrigerators

PRESSURE-ENTHALPY CHARTS AND THEIR USE By: Dr. Ralph C. Downing E.I. du Pont de Nemours & Co., Inc. Freon Products Division

Session: HVAC 101 HVAC 101. Steve Sain Sain Engineering Associates, Inc. August 9, Rhode Island Convention Center Providence, Rhode Island

Daikin Blueprint: Delivering Hot Water with a Chiller

General HVAC Recommendations

Chapter 9. Refrigeration and Liquefaction

Application of Air Source Variable Refrigerant Flow in Cold Climates

Air Conditioning Inspections for Buildings Efficiency of Air Conditioning Systems

Thermal Energy Transfer

2019 Smart Energy Existing Homes Program Manual

Geothermal Heat Pump Systems

Small Commercial Business Energy Audits. Recognizing and addressing the special requirements of the small business market segment.

Appendix 13. Categories of Cooling and Heating systems

Energy Efficiency Through Waste Heat Recovery. Heat Recovery Centrifugal Chillers and Templifier Water Heaters

HVAC 101. The Basics of Heating, Ventilation and Air Conditioning

Topic 2. ME 414/514 HVAC Systems Overview Topic 2. Equipment. Outline

Variable Refrigeration Flow Systems Overview 10/11/2016

Efficiency Vermont The American Institute of Architects Continuing Education Systems (AIA/CES) AIA/CES AIA/CES

Daikin VRV Systems Plugin VE2012 User Guide

COMMERCIAL HVAC SYSTEMS Water Source Heat Pump Systems

HVAC 101. H V A C S y s t e m s

2018 Smart Energy Existing Homes Program Manual

TEST REPORT #4. Travis Crawford Dutch Uselton. Lennox Industries Inc Metrocrest Drive Carrollton, TX 75006

UNIVERSITY OF MISSOURI Heating Ventilating and Air-Conditioning (HVAC) 2016 Q1

Chiller Plant Design. Julian R. de Bullet President debullet Consulting

Air Conditioning Inspections for Buildings Efficiency of Air Conditioning Systems

Temperature. In the HVAC area, we talk about two kinds of temperatures.

ELECTRICAL Seminar. B A L A Consulting Engineers, Inc. Edward J. Lynch, PE Vice President, Electrical Department Manager.

Chillers and Refrigerants. Purpose of Today s Presentation. Agenda. GLHN Architects & Engineers, Inc. APPA Institute Session 322 EU

Heat Pump Water Heaters

The Ed Roberts Campus Berkeley, CA

GARCIA GALUSKA DESOUSA Consulting Engineers

ASHRAE WILL GIVE YOU THE WORLD. This ASHRAE Distinguished Lecturer is brought to you by the Society Chapter Technology Transfer Committee

High Efficiency Heating and Cooling Systems for Community Colleges Kirk Mescher, PE, LEED AP Principal ICCCFO

AIR-CONDITIONING SYSTEMS AND APPLICATIONS. Abdullah Nuhait Ph D. King Saud University

INTRODUCTION HVAC BASICS AND HVAC SYSTEM EFFICIENCY IMPROVEMENT SECTION O 4/19/2012

DEMONSTRATION OF A MICROCHANNEL HEAT EXCHANGER FOR OPERATION IN A REVERSIBLE HEAT PUMP SYSTEM

Packaged Ammonia Chillers with Variable Frequency Drives powerpac

Lennox Mini-Split Systems Year-Round Comfort and Performance

High Performance Building Guide 1

Today s Webcast starts at 1:00 p.m. Eastern. You will not hear audio until the Webcast begins

Institute of Aeronautical Engineering (Autonomous) Dundigal, Hyderabad B.Tech (III II SEM) MECHANICAL ENGINEERING

DEMONSTRATION OF ADVANCED INTEGRATED HVAC&R SYSTEMS IN A LOBLAWS SUPERMARKET IN CANADA

b.) Technical Information:

Innovative Design, Performance, & Serviceability

Geothermal Heating and Cooling Using Ground Source Heat Pumps. Prepared by: Steven Forrester, P.E. Principal

Brazed Plate Heat Exchanger for CO Applications

Energy Use in Refrigeration Systems

Performance Rating of Variable Refrigerant Flow (VRF) Multi-split Air-conditioning and Heat Pump Equipment

HONORABLE MENTION: COMMERCIAL BUILDINGS, EXISTING

B. A. T. Basic Appliance Training

FAST AND ROBUST BUILDING SIMULATION SOFTWARE. Chilled Beam Performance: 1 Shelly Street, Sydney

Adsorption Chillers Energysmart Green Cooling

QUANTUM 340 LITRE TITAN HEAT PUMP WATER HEATERS AND THE APPLICATIONS

Update Dedicated Heat Recovery Chiller Technology. Don Frye. Gulf South

CALIFORNIA MECHANICAL CODE OVERVIEW OF 2016 UPDATES CHANGES AND RAMIFICATIONS

Daikin VRV Sizing & Simulation Plug-in User Guide

NON-REVERSING, 100% OUTSIDE AIR HEAT PUMP FOR HEATING AND COOLING

Water Source Heat Pumps

Performance Rating of Commercial and Industrial Unitary Air-Conditioning Condensing Units

Campbell Soup Company Extends Use of CO2 Systems Into Their Operations

State of the art building simulation software... Frenger Radiant chilled beam performance at 1 Shelly St - Sydney

New and Emerging HVAC Technologies. Rod Rhoads, GDS Associates Dave McCullaugh, Mitsubishi Electric Trane HVAC US Dave Binz, Cambridge Engineering

Water Source Heat Pumps. Energy efficient heating and cooling commercial applications

ENGINEERING BULLETIN. Overview of Chilled Beam Technology. Purpose. Summary. Theory

Closing the Loop What s best for your system?

MT. AIRY MIDDLE SCHOOL CARROLL COUNTY PUBLIC SCHOOLS

Inspection Phase Three. Mechanical, Electrical & Plumbing Section 503

AIR CONDITIONING. Carrier Corporation 2002 Cat. No

MECHANICAL SCIENCE Module 2 Heat Exchangers

Life-Cycle Energy Costs and Greenhouse Gas Emissions for Gas Turbine Power

SHConDEMAND. True Redundancy. Heating. Cooling. Simultaneous. Efficient. Reliable

Tighe&Bond. Groton Heights School Mechanical Evaluation. 1 Existing Conditions. 1.1 Water Service Entrance

A/C Cooling Load calculation and measurement

Sustainable Techniques in Refrigerated Space

Energy Savings Potential of Passive Chilled Beam System as a Retrofit Option for Commercial Buildings in Different Climates

Technical guides for owner/manager of an air conditioning system : volume 3. System recognition guideline for field visit

Mechanical Redesign, Proposal Elizabeth C. Krauss Mechanical Option September 18, 2013

Math. The latent heat of fusion for water is 144 BTU s Per Lb. The latent heat of vaporization for water is 970 Btu s per Lb.

Webinar: HVAC Claims Repair versus Replace Presenter: Curtis VanNess, General Manager HVAC Forensics Webinar Questions & Answers

If you have any questions, please feel free to contact me at (405) or via at

LENNOX MINI-VRF SYSTEMS. CONNECTING TECHNOLOGY WITH EXPERTISE.

LG VRF Systems. Air Conditioning Technologies

Large AC units using a variety of low-gwp options

EWAT-B. Multi scroll chiller with R-32 refrigerant. First air cooled chiller with environmental friendly R-32 refrigerant

INTRODUCTION TO: ASHRAE STANDARD 90.1, HVAC System Requirements for Reducing Energy Consumption in Commercial Buildings

Hybrid VRF Next Generation 2-Pipe Heat Recovery Systems

Transcription:

Leverage Building Energy Diversity in High Efficiency HVAC Design Water-source heat pumps prove to be more energy-efficient than alternative systems for commercial buildings. A version of this article was published on Consulting Specifying Engineer and can be accessed at http://www.csemag. com/single-article/the-benefits-of-using-water-source-heat-pumps/efa27bf58c27efcf687f2b84f1a7e8bb.html By Naveen Halbhavi, P.E ClimateMaster Inc. The first commercial energy code was promulgated in 1975 with the ASHRAE Standard 90-75 : Energy Conservation in New Building Design. Since then, subsequent efforts have led to more stringent energy efficiency standards, as shown in Figure 1. Figure 2: Total energy consumption in commercial buildings (in KBTU/sq. ft) has decreased 30% between 1979 and 2012. 2 Figure 1: Commercial Energy Code Stringency (measured on a code-to-code basis) 1. A study conducted by the Pacific Northwest National Labs shows a further 8.5% potential reduction in energy consumption by adoption of the 2013 standard. A complete and uniform adoption of these energy codes would have resulted in approximately a 50% reduction in normalized energy use between 1975 and 2012. In reality, total energy consumption per square foot in commercial buildings has decreased from 114 kbtu/sq. ft. in 1979 to 79.9 kbtu/sq. ft. in 2012 (Figure 2) a 30% decrease. While this is a significant achievement, adoption and enforcement of standards by different states Figure 3: Commercial Building Energy Consumption by Fuel Type. Commercial Buildings consumed almost 7000 trillion BTUs in 2012. has not been uniform and buildings continue to account for a large percentage of energy consumption in the US. According to the US Energy Information Administration, commercial buildings consumed 7 quadrillion BTUs of energy as shown in Figure 3. (A quadrillion is one thousand trillions let s just simply say that these

buildings consume a lot of energy). Further, HVAC accounts for 44% of the commercial building energy demand (see Figure 4) (includes space heating, ventilation and cooling; excludes refrigeration). heat from outside air during the winter. A WSHP is a type of heat pump that operates by rejecting heat to a water-pipe system (or water loop) during the summer or by absorbing heat from the same water loop during the winter. If multiple units of WSHPs are installed, they can all be serviced by a common water loop system (or header). Advantages of Water Heat Pumps (WSHP) Figure 4: Share of energy use in Commercial Buildings in 2012. HVAC (space heating, ventilation, cooling) accounts for 44% of total energy consumption. 3 Driving efficiency gains with HVAC systems, which account for 44% of a commercial building s energy consumption, will result in a large positive impact. In this article, we explore how Water Heat Pumps (WSHPs) are uniquely positioned to extract energy that is normally wasted and transport it to a place where it is being demanded thus offsetting new energy demand. We also explore other advantages that WSHPs offer such as high efficiency, reduced real estate footprint, improved safety, and better aesthetics in building design compared to alternative systems available in the market today. Commercial Heat Pumps A heat pump is a refrigeration circuit that can cool spaces during warm weather and heat spaces during cool weather. With a heat pump, you can cool or heat a space by only using electricity. By not burning fuel for heating, as in a traditional central furnace, a flammability risk is eliminated. Commercially available heat pumps can be categorized into two broad types: An air-source or air-cooled heat pump A water-source heat pump (WSHP) An air-source or air-cooled heat pump is a type of heat pump that operates by rejecting heat to outside air during the summer or by absorbing In WSHPs, since heat is transferred via a heat exchanger into a pipe carrying water, the system footprint is smaller since water is more efficient at carrying away heat than is air. In an air source system, the limiting heat transfer coefficient is on the air side and typical forced convection air side heat transfer coefficients are in the range of 25-250 W/m 2 K. By contrast, the forced convection heat transfer coefficients on the water side are in the range of 50 20,000 W/m 2 K. 4 This results in WSHP equipment being more efficient and smaller in size than air source heat pumps. Traditional air source units can require each air handling unit to have a separate outdoor condensing unit. For a large multi-unit system, as would be required in a commercial building, multiple outdoor condensing units would be needed that are not only noisy but also present a challenge to install since they require a lot of free space. With a multi-unit WSHP installation, heat exchange can be accomplished with a single central evaporative cooling tower or dry cooler located on the ground or the rooftop. (In one particular version of WSHP, the water loop runs underground and exchanges heat with the earth. Since the loop runs underground, the real estate footprint is minimized. This special version constitutes a geothermal heat pump and is not the focus of this article). The individual WSHP units themselves can be placed in dropped ceilings or hidden away in mechanical rooms or utility closets away from occupied spaces. Placing the units in ceilings, nearer the point of use, also results in less ductwork and less fan energy consumption. Fan energy consumption can be among the largest energy components of a HVAC system 5 and a good overall system design will acknowledge it and attempt to minimize this.

WSHPs also offer some of the highest cooling efficiencies in the HVAC industry. In fact, ASHRAE, the standards setting body for the industry, sets the minimum efficiency requirements for WSHPs to be higher than for traditional air cooled heat pumps and VRF systems. The following values (Table 1) for the Table 1: Mode Cooling Cooling Cooling Cooling Equipment Type Air Cooled Unitary Heat pump Air Cooled VRF Heat Pump Water VRF Heat Pump Water Heat Pump Size Category and and and and Subcategory or Rating Condition Split System and Single Package, 95 db, 75 wb VRF Multisplit System, 95 db, 75 wb VRF Multisplit System, 86F entering water 86 deg F entering water Minimum Efficiency most directly comparable units are taken from ASHRAE 90.1 2013. This comparison shows Reference 10.8 EER Table 6.8.1-2, Pg. 66 11.0 EER Table 6.8.1-10, Pg. 75 12.0 EER Table 6.8.1-10, Pg. 75 13.0 EER Table 6.8.1-2, Pg. 67 WSHP meets the highest EER requirement This table derived from ASHRAE 90.1 2013 shows that, under like conditions, the Water Heat Pump meets the highest EER requirement in Cooling mode Table 2: Mode Heating Heating Heating Heating Equipment Type Air Cooled Unitary Heat pump Air Cooled VRF Heat Pump Water VRF Heat Pump Water Heat Pump Size Category and and Subcategory or Rating Condition 47 db/43 wb outdoor air VRF Multisplit system, 47 db/43 wb outdoor air VRF Multisplit system, 50 F entering water 50 F entering water Minimum Efficiency Reference 3.3 COP Table 6.8.1-2, Pg. 67 3.3 COP Table 6.8.1-10, Pg. 76 3.6 COP Table 6.8.1-10, Pg. 76 3.7 COP Table 6.8.1-2, Pg. 68 WSHP meets the highest COP requirement This table derived from ASHRAE 90.1 2013 shows that, under like conditions, the Water Heat Pump meets the highest COP requirement in Heating mode. that WSHPs meet the highest minimum cooling EER (Energy Efficiency Ratio) requirement. The ClimateMaster TE026 offers an EER of 17.4 at full load and EER of 19.8 at part load at ASHRAE rated conditions which are well above the minimum thresholds. WSHPs are some of the most efficient performers even in heating mode when compared with alternative systems. In a furnace unit, the maximum efficiency for heating by burning natural gas is about 98.5% for a COP of 0.985 and by electrical heat is 100% (COP = 1.0). With a water source heat pump in heating mode, not only is the thermal energy from the water loop being extracted and utilized but also the heat of compression in the refrigerant circuit is captured and used as a source of heating. Due to this capability of extracting heat from a heat source (i.e. the water loop) and using the heat of compression, the Water Heat Pump can easily provide 4 to 6 units of heating for every unit of energy consumed. Clearly, this is a much more efficient system. Again, WSHPs satisfy the highest minimum ASHRAE COP requirement even in heating mode (Table 2) compared with traditional air cooled heat pumps or with VRF. The ClimateMaster TE-026 model, for example, has a Heating COP of 6.0 at full load and COP of 7.0 at part load at ASHRAE rated conditions which are well above the minimum threshold. In other words, the unit puts out 6 watts of heat for every watt of electricity consumed at full load conditions. Simultaneous Heating and Cooling with WSHPs Depending on the orientation of the buildings and the demands of different kinds of tenants in a multi-use location, it is normal for some of the occupants to be demanding cooling while some others are demanding heating at the same time. Or, there is demand for hot water in a restaurant

while the ice cream store next door is demanding cooling. Even within a single office building, for example in winter, there is usually need for heating at the perimeter that is exposed to the elements and cooling needed at the core of the building due to heat given off by occupants and Figure 5: A typical commercial building can have cooling loads at the building perimeter and heating loads in the building core. The WSHP loads at the perimeter (heating demand, shown in red) and in the core (cooling demand, shown in blue) can offset each other. equipment (Figure 5). This diversity of energy demand exists everywhere. Wouldn t it be the most efficient use of our resources if we could take the heat out of an area that is rejecting it and use it in another area that is demanding it? This is what Water Heat Pumps do and energy recovery and transport is an area where they truly excel. Water is non-flammable, non-toxic and has a high specific heat value of 4.2 KJ/kg C. It is an ideal medium to transport energy without any of the negative consequences of using a synthetic or flammable refrigerant to move energy, especially in the vicinity of occupied spaces. What gives the Water Heat Pump this unique ability to achieve this safely and efficiently? The BTUs of cooling load and the heat of compression in the refrigeration circuit of a traditional air source unit is rejected to the atmosphere through the condensing coil or the outdoor unit. The quality of heat is low and it is not economical in an air source heat pump to recover this energy. This energy is blown into the atmosphere and is thus wasted. In a water source heat pump, these BTUs are rejected into a common water loop and the water loop acts as a reserve of this energy that can be easily transported to the place that is demanding heating. As water is physically moved by means of a water pump to different areas of the same building, or a group of buildings, thermal energy is also being simultaneously transported. Even though the quality of heat is low, it is efficiently captured and transported to where it is needed due to the high heat transfer coefficients achievable with water and due to its high specific heat. The energy that is normally wasted in an air source heat pump is now recovered and used somewhere else, thus offsetting new energy demand. The overall building energy consumption is decreased and no BTU is left behind! Indeed, this is one of the biggest advantages of a Water Heat Pump - thermal energy can be recovered and economically, efficiently and safely transported to wherever water can be pumped. Since moving water is easy and safe, the WSHP can be applied to any situation from a single condo unit to a large office campus. The advantages of a WSHP deployment become even more apparent when compared with another system, the Variable Refrigerant Flow system or VRF. The VRF system has limited ability to transport energy over long distances since it uses refrigerant close to the saturation temperature, or with limited subcooling, in copper pipes as the transport medium and also because of compressor power and pressure drop concerns with pumping so much refrigerant. Most VRF vendors place limits on refrigerant tubing lengths such as how far the indoor units can be from the outdoor units; the total length of system piping allowable; the length from the first separation tube or branch controller to the farthest indoor unit; or the total vertical pipe length. In addition, there are also a large number of copper pipe connections that have to be made in the field in a VRF system. If there is a refrigerant leak anywhere along the path, it is extremely difficult to detect, isolate, re-braze, re-vacuum and re-commission the system. In a WSHP, all refrigerant lines are contained within the unit, and installed and leak-tested in a controlled factory setting. The energy in a WSHP system is moved by water in normal plumbing systems that every HVAC contractor is familiar with. This is much safer and easier to maintain and there are no piping distance limits. A further advantage of Water Heat Pumps is its ability to achieve highly efficient

operation and perform heat recovery while operating with a limited amount of refrigerant charge. High system refrigerant charges are a potential safety hazard since refrigerant can displace oxygen in closed rooms and cause asphyxiation without warning. ASHRAE Standards 15 and 34 (Safety Standard for Refrigeration Systems; and Designation and Classification of Refrigerants) defines the refrigerant concentration limit (RCL) and oxygen deprivation limit (ODL) for different refrigerants, and these can be used to calculate the smallest-sized room where a refrigeration system can be safely installed. For the most commonly used refrigerant, R-410A, the RCL is 26 lbs. per 1000 cubic feet and the ODL is 140,000 ppm. For institutional buildings such as hospitals, the threshold is only half of the nominal value (Institutional buildings defined as where occupants cannot readily evacuate without the assistance of others). The small quantity of refrigerant charge needed in a WSHP is contained completely within the factory tested unit. Again contrast this with a VRF system that requires much higher quantities of refrigerant charge. In a VRF system, refrigerant is not only used within the central units and their internal mini-split units but also is present in the extensive pipework and branch controllers between these internal and external units. Some VRF systems require two or three pipe network designs to work and all these pipes carry refrigerant. This complex maze of copper piping presents increased safety and maintenance risks due to the higher refrigerant charge in the system, higher number of connection points that are potential points of failure, and the hazard it poses if there is a leak. As the industry considers moving to refrigerants with flammable characteristics to meet the low Global Warming Potential (GWP) refrigerant requirements driven by climate change concerns, the safety considerations of using VRF become even more acute. In a VRF system, the RCL/ ODL thresholds can be easily exceeded in small offices, hotel rooms, bathrooms and utility rooms. 6 WSHP System Implementation A typical WSHP implementation in a large commercial building consists of several WSHPs that are installed close to the areas of demand and fed by a common water loop. The cooling tower, Figure 6: Multiple WSHPs are connected to a common loop or pipe header. This common loop is connected to a boiler and to a cooling tower. Water is then pumped around the loop using pumps. This picture shows a 2-pipe system which is the most common. pumps and boiler are located away from occupied spaces (Figure 6). In a WSHP implementation, the control schemes generally limit the water loop temperature to be in the range of 60F to 95F depending on the season. Keeping the water loop temperature in this range is a matter of economics and engineering judgement. The heat pumps can operate with water temperatures outside this range but their efficiency will be lower. For example, the heat pump has to work harder in heating mode with the water loop temperature at 55F than at 60 F. Is it more economical to let the heat pumps work harder at 55 F (consuming more electricity) or using the gas fired boiler to raise the temperature of the loop to 60 F? The answer depends on the relative costs of gas and electricity as well as the relative efficiencies of the boiler and heat pumps at these operating points. When both heating and cooling loads are present, the WSHPs extract the heat from areas rejecting it and provides it to the WSHPs that are demanding this heat through the common water loop. When the loads are able to offset each other, small temporary imbalances between

heating and cooling loads are taken care of by allowing the water loop temperature to float within the 60F to 95F range. In this scenario, there is no need for any net inputs to the system of either heating BTUs or cooling BTUs and both the cooling tower and boiler can be turned off to improve system efficiency (Figure 7). Due using a water-to-water WSHP. The reverse is true in winter when the heating demands exceed the cooling demands: a central boiler is provided to add BTUs to the water loop to make sure that the water loop temperature does not go below 60F (Figure 9). Since the cooling tower and boiler are sized to handle only the maximum net cooling and heating demand, as opposed to sizing for maximum total cooling and heating demand, their sizes can be reduced resulting in cost savings. Figure 7: The heating and cooling loads are able to offset each other in this scenario. The heat rejected by units in cooling mode is carried away to the heat pumps that are in heating mode. Both the boiler and cooling tower are turned off. to the large specific heat of water in the loops, a 35 degree F range in water loop temperature implies there is a large amount of thermal energy available to take care of demand imbalance. Just one thousand feet of 6 pipe can hold 875 KBTU of thermal energy over a 35 F span of temperature. Over a one hour period, this equates to over 70 tons of refrigeration that can be moved around. In cases where there are predominantly cooling loads, in summer for example, a central cooling tower is provided to provide only the net cooling to keep the water loop temperature from exceeding 95F (Figure 8). Alternately, the excess BTUs can simply be used to generate hot water Figure 8: Most of the units are in cooling mode. The cooling tower is on and the boiler is turned off. Figure 9: Most of the units are in heating mode. The cooling tower is off and the boiler is turned on. The WSHP industry continues to make strides in improving efficiency, even at part load conditions. Technologies like microchannel heat exchangers, variable speed compressors, BMS integration, wireless thermostats, and occupancy sensors are being tested or have already been implemented to further reduce energy usage and stay at the higher end of the efficiency spectrum. Conclusion WSHPs are a time tested efficient solution that have been successfully deployed in commercial buildings. They are especially effective in reducing energy consumption where there is diversity in energy demand and result in smaller sizes of cooling towers and boilers. By using water as a heat transport medium in a common water loop, WSHPs can move thermal energy across large distances safely and more efficiently compared to alternative solutions on the market. They are smaller and offer design flexibility by allowing the placement of towers, boilers and pumps in locations remote from occupied spaces. WSHPs eliminate flammability risk associated

with furnace heating and they accomplish highly efficient operation using much smaller quantities of refrigerant charge compared to VRF systems. Naveen Halbhavi, P.E is Director of Marketing for ClimateMaster, a leader in Water Heat Pumps. References 1. Energy Efficiency Trends in Residential and Commercial Buildings, US DOE, August 2010, Figure 38 2. http://www.eia.gov/consumption/commercial/reports/2012/energyusage/ 3. http://www.eia.gov/consumption/commercial/reports/2012/energyusage/, Figure 5 4. Fundamentals of Heat and Mass Transfer, Fourth Edition, by Incropera and Dewitt, 1996 5. Fan Demand and Energy, Steve Kavanaugh Ph.D., ASHRAE Journal, June 2000 6. Applying Refrigerant Codes, Greg Cuniff P.E, Taco Inc., HPAC Engineering December 2013 No BTU Left Behind It s common in mixed use developments for one space to be in cooling mode while another is demanding heat. ClimateMaster Water- Heat Pumps are designed to efficiently move energy rejected from one area to another where it can be used thus reducing new energy demand. By extracting energy that is normally wasted in traditional HVAC systems, we ensure that no BTU is left behind. To find out how we can assist you in your next project, contact us at 1-855-800-4436 and mention code ASHRAE to get a free consultation. To learn more about ClimateMaster mixed-use development applications go to climatemaster.com/ashrae. Midtown Exchange - Minneapolis, MN

ClimateMaster Water- Heat Pumps Provide comfort solutions that are easily scalable... Alta Condos at Thomas Circle - Washington D.C. from a one condo unit to a large office campus ASHRAE Headquarters - Atlanta GA Extensive range of vertical, horizontal, rooftop, stacked and split systems Improve aesthetics by minimizing footprint, ductwork and sound levels 855-800-4436 climatemaster.com/cse