SITE REPORT FOR CARE (CANADA) (Submitted by Rodica Nitu) Summary and purpose of document

Similar documents
Semiannual Maintenance and Calibration Report Prepared by Air Resource Specialists, Inc.

NFPA 2001: Standard for Clean Agent Fire Extinguishing Systems NFPA 70: National Electrical Code (NEC) NFPA 72: National Fire Alarm Code

Control Panel. 1.0 GENERAL SCOPE OF WORK Introduction... 2

SL-3 Vibration Sensor line A&E Specifications Page 1 of 12 SL-3 AE v doc

Operating Instruction Precipitation Sensors (15189) + (15189 HL)

Quick Installation Manual LED Touch Keypad Autodial Wireless Alarm System

Temperature Monitoring, Operation and Maintenance of Research Freezers and Refrigerators SOP-TMOMRFR-01

OPERATING INSTRUCTIONS Automatic Rain Gauge 1518-H3

Semiannual Maintenance and Calibration Report Prepared by Air Resource Specialists, Inc.

C-NRPP Quality Assurance Guidance for Radon Test Devices

Plug-in Base, Long Range Sensor E3B2

X64 Wireless Training

AIRSYS-P-SC-CHILLROW-E1503V01.1 CHILLROW. Row Cooling Precision Air Conditioner. Cooling Capacity: 26.2kW~68.6kW

[ [ ADMIN PANEL USER GUIDE

OPERATING MANUAL Enertronic Control System 2

Digi-Motor. ECM for Commercial Refrigeration. Toll Free (800) Fax (631)

VARIABLE REFRIGERANT FLOW FOR LODGING

PWM. Solar Charge controller with Ethernet. Solar Smart PWM 20Amp. Hardware Description : Release : 19 June 2014

S TEM PRODUCT SPECIFICATION

SYSTEM 5000 USER MANUAL

Appendix A Equipment Used to Monitor Hotels

Temperature Data Logging

TPOne-B. Electronic Programmable Room Thermostat. Installation Guide. Danfoss Heating

Davis Soil Moisture and Temperature Station Protocol

ISO/TS TECHNICAL SPECIFICATION. Fire detection and alarm systems Part 9: Test fires for fire detectors

Standard PRC Transmission Relay Loadability

IAAI/USFA Abandoned Building Project

ALPTEC Power factor controller

ISO Acceptance tests for Nd:YAG laser beam welding machines Machines with optical fibre delivery Laser assembly

G2484. Installation. - Control panel (in the panel front, on the inner wall, or on a DIN rail)

The Leading Enterprise Internet of Things Solution. Wireless Duct Temperature Sensors. General Description. Features of Monnit ALTA Sensors

1S25. Arc Fault Monitor 4 Zones, 8 Sensors. Features. Introduction. ARC Fault Protection

Sensor Cloud User Manual

Consultant Specification AGILE Wireless Fire Detection System

SAFETY CERTIFIED MODEL FP-700 COMBUSTIBLE GAS DETECTOR

PRODUCT CONFORMITY CERTIFICATE

Copying contents of this booklet or handing over to third party is strictly forbidden without written permission from Detector Oy.

PRODUCT CONFORMITY CERTIFICATE

Overview of FRAP-K1 And Status of Major Modifications

SOLARPEAK SITE ASSESSMENT FORM. I. Solar Access Assessment

SERIES VAC Microprocessor-Based Direct Spark Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION. Export Information (USA)

HOBO U30 Remote Monitoring Systems

XP95 Sounder VAD Base

RMS/RPX Reader. User Manual

ISO INTERNATIONAL STANDARD. Fire detection and alarm systems Part 16: Sound system control and indicating equipment

Mechanical Heat Pump R515

PROPOINT PLUS ASPIRATING SMOKE DETECTION SYSTEM

Dew point set DS 400

Ice Rink (Single and Dual Configurations) Custom Control Features

Session 2: LSA-SAF evapotranspiration: files, format and applications

CONTROL PANEL INTERFACE ACTIVATE THE GENERATOR DISPLAY INTERFACE MENUS. Control Panel USING THE AUTO/OFF/MANUAL SWITCH

ARGUS APPLICATION 9V937-A01C

OIL FILM DETECTOR (Flame-proof Version) SODL-1600

Addressable NAC Output Module D327A

EXPERIMENTAL PERFORMANCE ANALYSIS OF SOLAR AIR HEATER WITH THREE DIFFERENT MODIFICATIONS IN ABSORBER PLATE

Obstructions and ESFR Sprinklers Phase 2 FINAL REPORT

Model : LPSA-40A Please read this manual carefully before using the instrument Labnics Equipment

Senior Design Project Pre-Proposal Michigan State University College of Engineering. Dispenser Cup Content Detection

LI-830 and LI-850 Gas Analyzers. For Continuous Monitoring Applications

ISO INTERNATIONAL STANDARD. Fire detection and alarm systems Part 20: Aspirating smoke detectors

Independent Zone Control (I.Z.C.)

PRODUCT CONFORMITY CERTIFICATE

ET4 heat/cool day RF programmable room thermostat. ET4 Receiver

23" PANEL MOUNT INDUSTRIAL MONITOR REVISION C PRODUCT RELIABILITY TEST REPORT

Model 6495 Freezing Rain Sensor. User's Manual. All Weather Inc National Drive Sacramento, CA USA

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

Assessment of Domestic Evacuated Tube. Direct Solar Water Heater

ELSEMA MD2010. Application Controls automatic doors or gates when a vehicle is present. Description

Dahua 2-inch HDCVI Speed Dome Installation Manual Version Dahua Technology CO., LTD

TEST REPORT #34. Compressor Calorimeter Test of Refrigerant DR-7 in a R-404A Scroll Compressor

Centro-Matic Automated Lubrication Systems System Controls

TS400. Operating Manual. Test Station for Microtector II Series (G450/G460)

Dahua 2-inch Network Speed Dome Installation Manual Version Dahua Technology CO., LTD

7638 Standish Place Derwood, MD Tel: (301) Fax: (301) Page 1 of 12. Website:

Added password for IP setup page : Password must be in IP format!

Kidde Nitrogen Inert Gas Clean Agent Fire Suppression System

No previous protocol.

BSC-50 ADU-500. Autonomous RTUs

FLAME AMPLIFIER MODULE 3001

INTREPID Perimeter Intrusion Detection System

Semiannual Maintenance and Calibration Report Prepared by Air Resource Specialists, Inc.

Chapter 1 Introduction

Model 3300 Technical Support and Installation Manual

RC4000 Radiation Detection System

Manual GPRS Data Logger PCE-GPRS 2

A Comparison of Aspirated Smoke Detectors

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS

This document is a preview generated by EVS

MP 601A Humidity Probe INSTRUCTION MANUAL

Model Number Structure

RF280THS. Installation Instructions Wireless (RF) Photoelectric Smoke Detectors

Semiannual Maintenance and Calibration Report Prepared by Air Resource Specialists, Inc.

DESIGN, FABRICATION & PERFORMANCE ANALYSIS OF SOLAR AIR HEATER

Long Range Radio Alarm Transmitter

ISO INTERNATIONAL STANDARD. Fire detection and alarm systems Part 3: Audible alarm devices

In-line Oil in Water Analyser - Model OIW-EX100P and OIW-EX1000P

17" UNIVERSAL MOUNT INDUSTRIAL MONITOR REVISION E, F & G PRODUCT RELIABILITY TEST REPORT

Thermal Performance Enhancement of Inclined Rib Roughness Solar Air Heater

LaserFOCUS VLF-250 Engineering Specification

Understanding Surface Water Runoff at Breneman Farms

Transcription:

WORLD METEOROLOGICAL ORGANIZATION COMMISSION FOR INSTRUMENTS AND METHODS OF OBSERVATION INTERNATIONAL ORGANIZING COMMITTEE (IOC) FOR THE WMO SOLID PRECIPITATION INTERCOMPARISON EXPERIMENT (SPICE) Fourth Session CIMO/SPICE-IOC-4/Doc. 3(2) (6.VI.2013) ITEM: 3 Original: ENGLISH Davos, Switzerland 17 21 June 2013 SITE REPORT FOR CARE (CANADA) (Submitted by Rodica Nitu) Summary and purpose of document This document provides site report of CARE (Canada) for the 2012/2013 winter. ACTION PROPOSED The Meeting is invited to take this information into consideration when deciding on necessary modifications and clarifications on the overall set-up of the experiment and procedures to be followed to ensure best quality observations are collected on all sites and appropriate coordination and data transfer mechanisms are implemented.

Site: CARE (Egbert) Canada Site Report: IOC-SPICE-4 meeting Date: June 17, 2013 1. Site layout 1 P age

2. Configuration of References R1 Reference: Tretyakov Gauge in a DFIR fence Gauge: Tretyakov Gauge Shield type: Tretyakov Shield Collector Specifications Number of collectors: 2 Inlet area: 200 cm 2 Installation Height: 3 m Configuration of DFIR Fence Diameter: 12 m Height of Outer fence: 3.5 m Height of Inner fence: 3 m Heating: N/A Heating Algorithm: N/A Sampling Strategy: The manual gauge is read twice per day and recorded, nominally at 0800 and 1600 local time, 7 days per week. Output Interval: Once/day Manual Observation format Site Obs Time Inputter Input UTC Date UTC Weight (Cup + Precip) g Weight (Cup) g Weight Precip (g) Precip SWE mm Weather Conditions Notes Jan 18, 2013 16: 05: 00 CAR 13:26:00 Phil 1650.9 1638.3 12.6 0.63 SCT LWR CLD Scattered Lower Clouds Some frost on the collector 2 P age

R2 Reference: Geonor T-200B3 in a DFIR fence Gauge: Geonor T-200B3 Shield type: Single Alter Shield (Attached to post of the weighing gauge) Gauge Specifications Capacity: 600 mm Inlet area: 200 cm 2 Installation Height: 3 m Configuration of DFIR Fence Diameter: 12 m Height of Outer fence: 3.5 m Height of Inner fence: 3 m Heating Hardware & location Two Minco, Model HR23937 heaters are fixed to the Geonor orifice in the outside of orifice cylinder at top and the Outside of orifice cylinder at bottom (inside housing). One YSI44212 temperature sensor is mounted near the Geonor gauge. One YSI44003 thermistor is mounted on top of the Geonor orifice to monitor rim temperature. The temperature on the bottom of the rim is also monitored but for information purposes only. Heating Algorithm The heating status of the both heaters is controlled using the ambient temperature and upper rim temperature. The heating turns on when the ambient temperature is within -5 C to +5 C and the upper rim temperature is below +2 C. Heating ON : IF {-5 C <= ambient temperature <= +5 C} AND {upper rim temperature <= +2 C} Heating activation range (ambient temperature): -5 C to +5 C Rim set temperature: +2 C Sampling Strategy: 250 pulses/ 6 seconds Output Interval: 6 sec Output message format [Logger time][stin][precipitation Cumulative 1] [Frequency Transducer 1][Precipitation Cumulative 2][Frequency Transducer 2] [Precipitation Cumulative 3][Frequency Transducer 3][RimUpperTemp][RimLowerTemp][Air Temp][UpperHeaterOn][LowerHeaterOn] [LoggerBatteryVolt][LoggerTemp] 3 P age

R3 Reference (1): Geonor T-200B3 in a single alter shield Gauge: Geonor T-200B3 Shield type: Single Alter Shield (Attached to post of the weighing gauge) Gauge Specifications Capacity: 600 mm Inlet area: 200 cm 2 Installation Height: 2 m Heating Hardware & location Two Minco, Model HR23937 heaters are fixed to the Geonor orifice in the outside of orifice cylinder at top and the Outside of orifice cylinder at bottom (inside housing). One YSI44212 temperature sensor is mounted near the Geonor gauge. One YSI44003 thermistor is mounted on top of the Geonor orifice to monitor rim temperature. The temperature on the bottom of the rim is also monitored but for information purposes only. Heating Algorithm The heating status of the both heaters is controlled using the ambient temperature and upper rim temperature. The heating turns on when the ambient temperature is within -5 C to +5 C and the upper rim temperature is below +2 C. Heating ON : IF {-5 C <= ambient temperature <= +5 C} AND {upper rim temperature <= +2 C} Heating activation range (ambient temperature): -5 C to +5 C Rim set temperature: +2 C Sampling Strategy: 250 pulses/ 6 seconds Output Interval: 6 sec Output message format [Logger time][stin][precipitation Cumulative 1] [Frequency Transducer 1][Precipitation Cumulative 2][Frequency Transducer 2] [Precipitation Cumulative 3][Frequency Transducer 3][RimUpperTemp][RimLowerTemp][Air Temp][UpperHeaterOn][LowerHeaterOn] [LoggerBatteryVolt][LoggerTemp] 4 P age

R3 Reference (2): Geonor T-200B3 (No Shield) Gauge: Geonor T-200B3 Shield type: N/A Gauge Specifications Capacity: 600 mm Inlet area: 200 cm 2 Installation Height: 2 m Heating Hardware & location Two Minco, Model HR23937 heaters are fixed to the Geonor orifice in the outside of orifice cylinder at top and the Outside of orifice cylinder at bottom (inside housing). One YSI44212 temperature sensor is mounted near the Geonor gauge. One YSI44003 thermistor is mounted on top of the Geonor orifice to monitor rim temperature. The temperature on the bottom of the rim is also monitored but for information purposes only. Heating Algorithm The heating status of the both heaters is controlled using the ambient temperature and upper rim temperature. The heating turns on when the ambient temperature is within -5 C to +5 C and the upper rim temperature is below +2 C. Heating ON : IF {-5 C <= ambient temperature <= +5 C} AND {upper rim temperature <= +2 C} Heating activation range (ambient temperature): -5 C to +5 C Rim set temperature: +2 C Sampling Strategy: 250 pulses/ 6 seconds Output Interval: 6 sec Output message format [Logger time][stin][precipitation Cumulative 1] [Frequency Transducer 1][Precipitation Cumulative 2][Frequency Transducer 2] [Precipitation Cumulative 3][Frequency Transducer 3][RimUpperTemp][RimLowerTemp][Air Temp][UpperHeaterOn][LowerHeaterOn] [LoggerBatteryVolt][LoggerTemp] 5 P age

3. Changes made during the season 12/13 No changes made to the reference configuration from Dec 01, 2012 to April 30, 2013. 4. Issues Issues noted during the operating of the site related to: Heating - No heating issues observed. Capping No capping issues observed. Vibrations of the mast The Geonor pedestal is 30 kg, made of cast iron and it s mounted on a concrete base which significantly minimizes vibration effects due to wind speed. Vibrating of the gauge None. Orientation The three Geonor transducers are oriented in a way that each transducer is facing North, South East or South West. Measured precipitation co-varies with changes in temperature due to solar heating, as the sun rises and sets, its position changes in the horizon which may affect the vibrating wires independently due to their difference in orientation. Significant variations can be observed in non-precipitating conditions on a cloudless clear day. Grounding No grounding issues observed. Length and type of cables and connections used No issues. Materials - : Coefficients of thermal expansion of the gauge components may influence precipitation values. Further study is being done on this topic. Data sampling- No issues observed. Data Output: - Data logger failing to send the expected message, resulting in no data <ND> due to data corruption, and is corrected after a few messages. - Wireless connection Interference, no connection with the computer, data stored in a buffer and dumped all at once) Data quality - No issues observed. 6 P age

5. Heating report: Summary of configurations throughout the winter of 12/13: Hardware I. How was it implemented Two Minco, Model HR23937 heaters are fixed to the Geonor orifice in the outside of orifice cylinder at top and the Outside of orifice cylinder at bottom (inside housing) see figure 2. One YSI44212 temperature sensor is mounted near the Geonor gauge. One YSI44003 thermistor is mounted on top of the Geonor orifice to monitor rim temperature. The temperature on the bottom of the rim is also monitored but for information purposes only. II. Power applied Both heaters are powered in parallel using a DC power supply. - Power supply: 12VDC - Heater resistance: ~5.1 Ω (each heater) - Heater power: ~28.2 W (each heater) Software The data logger is programmed to control the status of both heaters by monitoring the ambient temperature and upper rim temperature. The heating turns on when the ambient temperature is within -5 C to +5 C and the upper rim temperature is below +2 C. Heating ON : IF {-5 C <= ambient temperature <= +5 C} AND {upper rim temperature <= +2 C} Heating activation range (ambient temperature): -5 C to +5 C Rim set temperature: +2 C 7 P age

Heating - Topics to study 1) Comparison between heated and non-heated gauges with the same shield configuration over a specific events or extended periods to study evaporation loss. 2) The effect heaters have on gauge performance (Noise). 3) The need to extend heating to additional surfaces. 6. What has worked well? - Having Phil Raczynski and Jeff Anderson available at the CARE site reduced the instances of missing data. - The CARE site team consists of 12 members, who contribute to the running of the experiment in addition to their regular responsibilities. Their dedication and efforts have increased our efficiency. - The close proximity of the site to the office. 7. What has not worked well; Lesson Learned - The competing priorities of the team led to delays in configuration of the instruments; 8. Data Available i. 150 days of data were collected for each sensor site. ii. No data files were transmitted to NCAR as of May 27, 2013; the person assigned to prepare the files for transfer is testing the routines iii. All data was QC d using OSE applications. iv. Issues in data: - Missing records. - Missing fields. - Correct/Incorrect file sizes reported. - Missing time stamp. - Fields containing unexpected characters. (Data logger fails to send the expected message; result is No Data. The next message will have the previous and present message). - Duplicate records 8 P age

9. Instruments under test List of instruments under test: I. OTT Pluvio2 weighing gauge, Single Alter, Heated. II. OTT Pluvio2 weighing gauge, Belfort Double Alter, Heated. III. CAE S.P A PMB25R Tipping Bucket. IV. Hydrological Services America TBH/TBH-LP Tipping Bucket. V. Meteoservis MR3H-FC Tipping Bucket. VI. ZAMG MR3H-FC Tipping Bucket. Have you had any problems with instruments under test? Pluvio2 built up snow on the shoulders in BDA, even for moderate snowfall Have all instruments allocated to your site from Instrument Providers, been installed? No, the Meteorological Particle Sensor from Droplet Measurement Technologies was not installed in CARE. It is scheduled to be installed in Boulder this summer. Has the data been shared with the Instrument Providers? Yes. The following files were shared with each Instrument Provider: I. The file for the instrument proposed by the manufacturer. II. Temperature data YSI 44212 III. Humidity data Vaisala HMP155 IV. 2 meter wind data - Vaisala NWS425 V. 10 meter wind data RM YOUNG 5103 Did an Instrument Provider visit the site? No. 9 P age

10. Information on the Precipitation Detector(s) used The DRD11A is the precipitation detector used in CARE. 11. Commissioning I. Date: December 1, 2012 II. Configuration at commissioning: See CARE Commissioning Protocol report. 12. Results to date: - Comparison of shield performance; - Evaluation of the Pluvio 2 data fields - Assessment of Geonor 600 mm vs 1000 mm; - Filtering methodologies. 13. Interaction Site manager and the IOC and Project team Current methods of interaction between Site manager, IOC and project team are: - Weekly/Bi-weekly teleconference meetings. - Emails. - Blog on the Cspice website. 14. Small things, Big impacts. Positioning of transducers, wires, within housing can impact gauge performance: - In the example below, see marked change in output from 1500 mm gauge after wires were fixed to avoid contact with housing interior. - Of particular concern for higher capacity gauges (1000 mm, 1500 mm), for which available space within housing is limited. - Heated gauges present an additional challenge even more wires to fit inside housing. 10 P age

11 P age