HEATING-COOLING UNIT UGCH

Similar documents
HEATING AND COOLING UNITS BRAVA

FHTERM HEATING AND VENTILATION UNIT

Technical documentation: S1 S2 S3 S4

Technical documentation

Technical documentation DTR

Technical documentation DTR AIR WATER HEATERS IN EPP CASING HC-3S SERIES

Technical documentation WATER HEATED AIR CURTAIN MODELS: REVENTON GROUP AERIS 100WN-1P REVENTON GROUP AERIS 150WN-1P REVENTON GROUP AERIS 200WN-1P

Air-Water heat pump Small GT

USER S MANUAL. VCU/VCUN Series CENTRIFUGAL FAN IN SCROLL CASING

OPERATION AND MONTAGE MANUAL ROOF FANS

Technical documentaton DTR. Farmer

Technical documentaton DTR. Farmer

Technical documentation DTR. Farmer HCF in EPP casing

TECHNICAL DOCUMENTATION DTR AIR WATER HEATERS IN STEEL CASING S SERIES

TECHNICAL DOCUMENTATION DTR AIR WATER HEATERS IN STEEL CASING S SERIES

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

Instruction Manual. Alarm Unit For Low Gas Level # Read manual before use! Observe all safety information! Keep manual for future use!

OPERATION AND MONTAGE MANUAL ROOF FANS

SMART EVO 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS

USER GUIDE. DRENA 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS - WASTE WATER -

CENTRIFUGAL FAN IN SCROLL CASING. Helix S-Vent OPERATION MANUAL

TQ Series. Electronic Control Pump Instruction Manual. 50Hz. ISO 9001 Certified Walrus Pump Co., Ltd.

TECHNICAL AND OPERATIONAL DOCUMENTATION

TTV 4500 / TTV 4500 HP / TTV 7000

ATM Lighting sp. z o.o

SG-WS type EXCHANGERS FOR TAP WATER HEATING ELECTRIC STORAGE TAP WATER HEATERS GUARANTEE CERTIFICATE. volume: 80, 100, 120, 140, 200, 300 and 380 dm 3

TFV 900 OPERATING MANUAL RADIAL FAN TRT-BA-TFV900-TC-001-EN

USER S MANUAL. Heat (Energy) Recovery Ventilator. Vents Frigate HRV 120 S Vents Frigate ERV 120 S

CP-200 Push Button. CP Warewash Pump Instruction & Operation Manual Push Button , Rev1.0,

HEAT RECOVERY AIR HANDLING UNIT

USER S MANUAL. Heat Recovery Ventilator. Vents Brig HRV 200 Vents Brig HRV 300

CP-200 S&T. CP Warewash Pump Instruction & Operation Manual Speed & Time , Rev1.0, , Page 1 of 8

ST1. Mod. USE AND MAINTENANCE MANUAL

INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL

Room panel. for ecomax800 R or T regulators. OPERATION AND MAINTENANCE MANUAL ISSUE: 1.3 APPLICABLE TO SOFTWARE: v , v , v08.21.

TERM-E ELECTRIC HEATING AND VENTILATION UNITS

NHS VERTICAL AGITATOR

Declaration of Conformity No. 27/2008

2 INLET / HIGH HEAD DRAIN PUMP SYSTEMS MODELS , INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

OPERATION MANUAL CENTRIFUGAL INLINE FAN WITH ELECTRONICALLY COMMUTATED MOTOR VKM EC SERIES. F88EN-02.indd :07:11

AXIS-QA G TUBO-M/MZ AXIAL FANS. Axis / Tubo OPERATION MANUAL

USE AND INSTALLATION HANDBOOK

Specification / Type INTEGRA 400/100 INTEGRA 500/120 INTEGRA 800/200

РУКОВОДСТВО USER ПО MANUAL ЭКСПЛУАТАЦИИ CENTRIFUGAL INLINE FANS VKM / VKMZ / VC SERIES

EUROSTER 11Z CENTRAL HEATING / UTILITY HOT WATER PUMP CONTROLLER

INSTANT HOT WATER DISPENSER

HEATING AND COOLING DEVICE AGC

Turin LED Ceiling Fan

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

Operating manual. Pellet boiler. Orlan Pellet ISO 9001

USER MANUAL. Frigate HRV 120 SR Frigate ERV 120 SR. Heat (energy) recovery ventilation unit

Ceiling Mount Air Purification System

Operating Manual BDC 1216

USER S MANUAL BUCKET FAN SERIES BUCKET FAN WHISPER SERIES

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS

Withdrawable module with vacuum circuit-breaker 3AE and installation accessories kv, ka kv, 40 ka 24 kv, ka

WATLOW IND. WATROD Modular Duct Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2

THE BARCLAY HUGGER CEILING FAN INSTALLATION INSTRUCTIONS

Ceiling Sweep Fan Assembly Instructions

USER S MANUAL. Centrifugal inline fan. VKMz 100 Q VKMz 100 VKMz 125 Q VKMz 125. VKMz 250 Q VKMz 250 VKMz 315 Q VKMz 315

NXM2G Installation and Operating Manual

Installation, Operation and Maintenance Manual for the Potable Water System Model: PWS-01 (380 VAC Suppy x 24 VDC Controls)

Installation Guide. Termix Distribution unit. 1.0 Table of Contents. 1.0 Table of Contents

KOSPEL S.A. UL. OLCHOWA KOSZALIN

User s Manual MATRIX A MATRIX S MATRIX A. Filtro de aspiración Movil Matrix Tel.

HOT TAP WATER EXCHANGER with solar pump-group ENSOL IT INSTALLATION AND OPERATION MANUAL WARRANTY CARD

CPX MEDICAL AIR PLANT INSTALLATION, OPERATIONS & MAINTENANCE MANUAL

Operating instructions Safety-monitoring module SRB 302X3. 1. About this document. Content

IMPORTANT SAFETY INFORMATION:

The warranty card and conditions are effective only in the area of Poland.

ATM Lighting sp. z o.o

HORIZONTAL MULTISTAGE CENTRIFUGAL PUMP

WAILEA OWNER S MANUAL

(1135/2016) Translation from Finnish Legally binding only in Finnish and Swedish Ministry of Economic Affairs and Employment, Finland

SOTTOSTAZIONI PER TELERISCALDAMENTO DISTRICT HEATING SUBSTATIONS

EUROSTER 11E CENTRAL HEATING/UTILITY HOT WATER SYSTEM PUMP CONTROLLER

Technical Guide. Installation, Operation and Care. EP E series 7 step electric boilers 26 and 42 kw

user s information manual

Hawkins 44 in Ceiling Fan Owner s Manual. Hawkins Ventilador de Techo de 1,12 m Manual del Propietario

WHE 2.24 / WHE 2.24 FF

CPC PRODUCT DESCRIPTION

USER'S MANUAL PGE Single Package Rooftop

Irene-H READ AND SAVE THESE INSTRUCTIONS

ERAH MC Ka. Range kw. AIR COOLED CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS FOR OUTDOOR INSTALLATION (Standard line)

SPACESAVER INSTRUCTION MANUAL WARRANTY CERTIFICATE

HEAT RECOVERY VENTILATOR

FSW300 Series Flow Switch

INTELLIGENT AXIAL FAN user's manual

Use and Maintenance Manual. WPA-E-N/Ex. II 2 G c Ex e II T3. ATEX marking: Explosion proof stand fans WPA-E-N/Ex

INSTALLATION, OPERATION AND MAINTENANCE MANUAL FOR COMPACT POINT-OF-USE ELECTRIC WATER HEATER

Assembly instructions for Minib convectors

INLINE CENTRIFUGAL FAN. Centro-M OPERATION MANUAL

Unpacking Your Fan 2.

Grinding mill MISTRAL 50L (art. 650P)

EUROSTER 11W CENTRAL HEATING SYSTEM CONTROLLER

ADVANTAGE SERIES KXRP28 AIR-TO-AIR HEAT EXCHANGER

(3 plastic wire connectors,blade balancing kit, 2 extra mounting screws #10-32 for outlet box.)

SERIES 4000 AUTO GATE MANUAL

Instruction Manual HWR MODEL RESISTO-FLO ELECTRIC BOILER

IPVB EC inline power venter

Transcription:

Szymañski, Nowakowski Sp. j. ul. Lubelska 31, 08-500 Ryki tel. +48 81 883 56 00, fax +48 81 883 56 09 POLSKA HEATING-COOLING UNIT UGCH I. BRANCH OFFICES OF THE COMPANY II. ORIGINAL MANUALS III. SPECIMEN OF EC DECLARATION OF CONFORMITY IV. TERMS OF GUARANTEE V. DEVICE START-UP REPORT VI. OVERHAULS AND MAINTENANCE SHEET VII. SERVICE REQUEST VIII. LIST OF SUBASSEMBLIES MOUNTED IN THE DEVICE Before starting any works, read the manuals carefully. RYKI 2012 VERSION 1 PL

I. BRANCH OFFICES OF THE COMPANY Bia³ystok Poznañ GSM +48 692 478 020 GSM +48 692 473 053 e-mail: bialystok@juwent.com.pl e-mail: poznan@juwent.com.pl Gdañsk Rzeszów GSM +48 692 473 056 35-210 Rzeszów, ul. Baczyñskiego 1 e-mail: gdansk@juwent.com.pl Tel. +48 17 853 50 09, Fax +48 17 853 50 09 GSM +48 660 771 537 Kielce e-mail: rzeszow@juwent.com.pl GSM +48 606 618 860 e-mail: kielce@juwent.com.pl Szczecin 71-011 Szczecin, ul. Mieszka I 80, Kraków Tel. +48 91 489 64 46, Fax +48 91 489 64 46 30-683 Kraków ul. Nowos¹decka 46 GSM +48 608 539 432 Tel. +48 12 655 90 63, Fax +48 12 655 97 50 GSM +48 664 197 142 e-mail: krakow@juwent.com.pl e-mail: szczecin@juwent.com.pl Œl¹sk 41-200 Sosnowiec, ul. Narutowicza 50 Lublin Telefon: 032/ 293 54 47, Fax 032/ 293 54 47 GSM +48 692 476 090 GSM +48 604 978 536 e-mail: lublin@juwent.com.pl e-mail: slask@juwent.com.pl ódÿ Warszawa 93-486 ódÿ, ul. Zamojska 16 02-954 Warszawa, ul. Kubickiego 7/13 Tel. +48 42 682 70 55, Fax +48 42 682 70 56 Tel. +48 22 613 13 80, Fax +48 22 613 39 73 GSM +48 502 087 843 GSM +48 600 998 676, +48 602 195 709 e-mail: lodz@juwent.com.pl e-mail: warszawa@juwent.com.pl Olsztyn Wroclaw GSM +48 606 908 820 50-542 Wroclaw, ul. Zegiestowska 11 e-mail: olsztyn@juwent.com.pl Tel. +48 71 787 21 60, Fax +48 71 787 21 61 GSM +48 601 974 999, +48 0601 671 566 e-mail: wroclaw@juwent.com.pl 2

II. ORIGINAL MANUALS HEATING COOLING UNITS UGCH size 1 2 3

TABLE OF CONTENTS PURPOSE 5 MARKINGS 5 DESCRIPTION OF THE DEVICE 5 TECHNICAL DATA 6 TRANSPORT 6 SECURITY RECOMMENDATIONS 6 ASSEMBLY 7 ELECTRICAL INSTALLATION 8 AUTOMATICS 8 DEVICE START UP 9 REPAIR, MAINTENANCE AND WITHDRAWAL FROM EXPLOITATION 9 REMOVAL OF FAILURES 11 INFORMATION 11 4

PURPOSE Heating-cooling units UGCH size 1 and 2 are intended to heat and cool such facilities as commercial pavilions, shops, supermarkets and all others where there is a need to heat the space in the heating period and cooling during the summer. 3 Units may not be used in areas with absolute humidity higher than 95% and air dusting above 3 mg/m. MARKINGS Heating-cooling unit UGCH- Size 1; 2 Number of rows of a heater II, III DESCRIPTION OF THE DEVICE The unit consists of: - axial fans (1) mounted on the lower wall of the unit with a rotor's safety device in a form of a mesh; - plate heat exchangers (2) (2 pcs. for each unit) in the frame made of galvanized steel sheet. Plate heat exchangers are performed from copper tubes with an external diameter D=10 mm and aluminum plates with a spacing of =2,0 mm. Exchangers of the units are connected parallel with each other. Stub connections of the units have internal screw threads. o For the plate exchangers, max temperature of a heating agent amounts to 110/70 C and working pressure up to 1MPa. Note: There is a danger that a heating agent may freeze in exchangers placed in the rooms with the temperature o below 0 C. A danger may be limited by means of using anti-freeze thermostat (provided at the request), application of non-freezing heating agents or emptying water from the unit. - housing (3) made of steel sheet powder painted with one-row air grates. The blades of air grates allow for setting a direction of air ventilated. A construction of blades secures against selfredirection thereof. - condensate-collecting drain pans (4) (2 pcs. for each unit), to which the polyethylene tubes discharging the condensate to the sewage system are attached. - outflow of condensate (5). The manufacturer reserves the right to introduce changes. 3 1 2 4 5 5

TECHNICAL DATA Basic dimensions 1" 360 Size of the unit 765 1390 765 for UGCH - 1 UGCH-1 Air capacity [m3/h] 2000 Parameters of the unit surrounding and an motor of the fan UGCH-2 Type of the fan FE 031 ( 1 fan) FE 031 (2 fans) Row number of a heater II III II III Weight [kg] 54 68 102 115 Scope of air temp. [oc] 0-70 0-70 Max air humidity [%] 95 95 Max contents of dust [mg/m3] 3 3 IP Group 54 54 Insulation class F F From the distance of 1m* From the distance of 3m* Noise [db(à]) 54 51 2 *Loudness - level of acoustic pressure taking into account an absorption ability of the room À=50m and slope Q=2. 4000 56 52 TRANSPORT The units are delivered fully assembled, secured externally with polyethylene foil against contamination and atmospheric conditions. The Product Handbook is delivered with the unit. The units should be transported in on layer in the manner which prevents from mechanical damages. SECURITY RECOMMENDATIONS Heating-cooling units should be used in accordance with the operation manuals. Start-up, assembly, connection, overhauls and repairs of the unit should be performed by a skilled fitter and in case of electrical works by the person with the required qualifications to perform electrical works. All maintenance and repair works should be performed with the voltage switched off. In case of a failure of the unit, the electricity to the electrical motor of the fan should be immediately turned off and the water supply to the exchangers should be turned off. The unit may operate only with properly functioning electrical safety devices. It must be permanently connected to the electrical system equipped with a protective clamp, differential-current fuse and service switch. Be careful not to swap the protective lead with supplying ones. Only original spare parts should be used. It is forbidden to operate the unit with a fan without a protective mesh. 6

Due to the structure, the device does not emit harmful radiation. Note for the user! Installing or exploiting the heating-cooling device in the manner which is inconsistent with the operation manuals may cause a damage to the unit and the loss of guarantee. Despite the fact that the device was designed and performed in accordance with the requirements of the standard, in accordance with its condition upon being started, a likelihood of an injury or the loss of health in exploitation is unavoidable. This likelihood is related with a frequency of an access to the device during its exploitation, cleaning or repair, presence of the persons in a hazardous zone, conduct which is inconsistent with the safety principles described in the manuals. A degree of the body's seriousness or deterioration in health condition depends on many factors which may be foreseen only to a certain extent, taken into account in the structure of the device, describing and warning in the manuals. Therefore there is a residual risk in case of non-compliance with the guidelines and recommendations contained in the manuals by the user. ASSEMBLY Hanging the unit In the Upper part of the housing, there are four rivet-nuts for screwing in screwed bars M8 for suspending the unit to the ceiling or the roof structure. Screwed bars must be screwed in rivet-nuts of the housing at the depth of min.15 mm and must be secured with counter-nuts preventing the bars from screwing out from the housing. The units must be leveled in order to enable the discharge of condensate from drain pan. Minimum necessary distance of the unit from the wall in order to assure the possibility to take out heat exchangers and drain pan collecting condensate for cleaning amounts to: - 150 cm for UGCH-2-80 cm for UGCH-1 The access to exchangers and drain pan is obtained by means of unscrewing elements of the housing marked on the figure from both side walls of the unit housing. Elements of the housing 4 Minimum distance of the unit from the ceiling amounts to 10 cm. The ceiling or the roof structure must be adjusted to load with the weight of units. Water system It is planned to supply the units from two-pipe system with so called cold'' in summer or with hot water in the heating season. It is recommended to: -connect the unit to the network with a lower connection of exchangers and the return of the agent with the upper one; -use a cut-off valve in front of and behind the unit in order to enable its disassembly without the need to empty the supplying system; Electrical valves should be connected on the return of the heating agent from the device. The venting and dewatering of the exchangers of the units are forecast to be performed central in the network. Vents and discharge valves placed in the system behind the unit should be used. 7

Careless venting of exchangers may be the reason for not achieving assumed parameters by the unit. The stub connectors of exchangers must not bear the load of system cables. While connecting the exchangers to the network, stub connectors of exchangers should be protected from being twisted off in the manner presented in the figure. Note: Damages of the exchangers caused for the above reason are not covered with the guarantee. The discharge of condensate from the unit is planned to be gravitation type and with minimum drop of ~2% to the properly performed sewage system. The manufacturer does not bear any responsibility for the losses resulting from improper installation of condensate discharge. ELECTRICAL SYSTEM The performance of the electrical system and connection of supply to the unit must be performed in accordance with proper requirements of standards and construction provisions. Electrical connections to the unit may be performed only by the authorized electrician, acquainted with the operation manuals. Before starting the connection, make sure that the voltage values or supplying network frequency are consistent with the data provided on the data plates of the units. In case of inconsistency, do not connect the device. The units are equipped with tri-phase fans (3~400V/50 Hz) with internal thermal contacts (Tc). Electrical connection of fans should be performed while taking into account both the disconnecting device (in which the distance between the contacts of all poles amounts to no less than 3mm) as well as overload and circuit protection devices. The circuits supplying fans should be placed into the clamp box and mounted to the protective mesh or brackets of fans with clamp belts. Thermal contacts (Tc) of fans should be connected to the circuits steering the supply of fans. Electrical connection of the motor must be consistent with electrical diagrams in a clamp box. An exemplary diagram of connections and steering of the unit is provided on the figure 1. Note! The lack of factory connection of thermal protection (Tc) or (PT) of the motor results in the loss of guarantee. AUTOMATICS We can provide the following with the units: - rotational velocity regulators; - two-way or three-way valves with an electrical servo-motor; - room thermostats; - anti-freezing thermostats; -supply-control boxes (equipped with: main switch, overcurrent switchers, short-circuit switchers, signaling lamps) intended for cooperation and steering elements of automatics as above. It is possible to control a set of units from the control box with one thermostat. The supply of the supply-control box 3x400V/50Hz should be performed from the main switchboard equipped with the main switch and differential protection. In case of ordering the automatics with the unit, the company delivers also an electrical diagram of the unit and automatics. 8

START-UP OF THE DEVICE Before the start-up: - check the condition of the unit mounting (check also the leveling of the unit) - check tightness of water connections - check supplying voltage in accordance with electrical plate - check additional protection of a fan and housing of the unit - check correctness of the electrical motor connection - check rotating direction of the fan. In order to switch the unit on: - open valves of a cooling and heating agent - switch on the supply of current to the electrical motor - adjust direction and scope of the stream of ventilated air by means of venting grate blades In order to switch the unit off: - close the valves of a cooling or heating agent to the exchangers of the unit - switch off the supply of the currency to the electrical motor of the fan With long-term start-up of the unit or in case of break in the operation of heating network, exchangers should be dewatered and, alternatively, cut off valves should be closed. REPAIR, MAINTENANCE AND WITHDRAWAL FROM EXPLOITATION The rolling bearings of the fan do not require periodical lubricating. However, it is recommended to conduct periodical checks of the bearings' conditions (a rotor of the fan should revolve freely, without excessive clearance and slapping ). With an increase in noise of the unit's operation, check the correctness of mounting of the fan and the whole unit. Blades of the rotor should be cleaned with a wet cloth, after the protective mesh has been removed in order to prevent from balancing the rotor. High-pressure washers must not be used for cleaning the fan. With all interruptions in the units' operation, contact the fitter or the service. All repair and maintenance works should be performed with the voltage switched off. The unit should also be protected against accidentally being switched on by other persons. Check the condition of the exchangers contamination periodically. Contaminated exchangers should be blown with compressed air. Contamination of exchangers reduces the air efficiency and cooling or heating power of the unit. Before summer, clean the condensate collecting drain pans and check the patency of condensate discharging tubes to the sewage system. After withdrawal from exploitation, the device should be transferred to a specialized collection points of recyclable minerals. 9

1 MOTOR OF THE UNIT MARKING TO THE DIAGRAM: PT1,PT2 - Overcurrent circuit breaker the motor K1,K2 - Contactor PZ - Steering connecting button PW - Steering switching button B1,B2,B3 - Fuses PE- Protective clamp Tk - Thermal protection MOTOR OF THE UNIT MARKING OF MOTOR'S CABLES: U1 - brown U2 - red V1 - blue V2 - grey W1 - black W2 - orange Tk - white Fig. 1 Exemplary diagram of connection and control of the UGCH unit 10

TROUBLESHOOTING Description of the Leak of heat exchanger Possible reasons for failure mechanical damage of the exchanger (likely to occur with careless connection of the device to the system) Prevention/removal controlling key must be absolutely used in assembly with installation exceeding permitted parameters of a heating agent freezing of an exchanger the device must be connected with heating system secured against excessive increase of pressure and temperature use anti-freezing thermostat, non-freezing heating liquids or empty water from the device in the shutdown period and a risk of freezing Too loud work of the device using the device in aggressive environment failing to keep minimum distance from the wall or the ceiling improper direction of revolutions improper parameters of the supplying power system choking the air outlet with shutters of the outlet grate use distances recommended in the manuals perform proper electrical connection use the device only in case of consistency of the parameters of the supplying network and the device avoid significant closing the shutters of the outlet grate at high velocities Fan does not work vibrations of the fan, blades brushing fixed elements non-centric mounting of the fan in its bearing plate incorrect or insecure electrical connections improper parameters of the supplying electrical network (the lack of three phases in tri-phase) damage to the motor of the fan damage to elements of control the fan check the correctness of mounting the fan and proper mounting of other elements of the device check and alternatively correct: 1)consistency of electrical connections with diagrams from the manuals 2) certainty of connections at electrical clamps 3)parameters of supplying system Regulator of revolutions ARW/RTRD does not work correctness of electrical connections (careful tightening the leads in electrical clamps) connection only and exclusively of 1 adjuster to 1 unit check and alternatively correct: 1)consistency of electrical connections with diagrams from the manuals 2) certainty of connections at electrical clamps 3)parameters of supplying system Servo-motor does not open the valve correctness of the thermostat operation (characteristic click while switching) check and alternatively correct: 1)consistency of electrical connections with diagrams from the manuals 2) certainty of connections at electrical clamps 3)parameters of supplying system 4) whether a servo-motor reacted to electrical impulse. If we state the damage to the servomotor, the complaint should be lodged to the damaged element Room thermostat connection of more than one unit directly to the thermostat (a larger number means overloading the thermostat) place of mounting the thermostat in the room check and alternatively correct: 1)consistency of electrical connections with diagrams from the manuals 2) certainty of connections at electrical clamps 3)parameters of supplying system 4)if you do not hear characteristic click, thermostat is mechanically damaged and it should be complained INFORMATION In all issues concerning the UGCH units, contact Manufacturing Plant JUWENT or our Representation Offices. 11

III. TEMPLATE OF EC DECLARATION OF CONFORMITY NR: 01/12 Authorized representative Szymañski, Nowakowski Sp. j. ul. Lubelska 31, 08-500 Ryki, POLSKA tel. +48 81 883 56 00, fax +48 81 883 56 09 www.juwent.com.pl info@juwent.com.pl The person authorized to prepare technical documentation Piotr Leszko, ul. Lubelska 31, 08-500 Ryki, Polska We declare that the goods: Heating-cooling device Type: UGCH -...-... with serial number:... to which the declaration refers conforms to the directives listed below: Directive number Symbol Title of the directive 2006/42/WE MAD Safety of machines 97/23/WE PED Pressure device with subassemblies meeting the requirements of the directives: 2006/95/WE 2004/108/WE LVD EMC Low-voltage electrical devices Electromagnetic compatibility and the following standards Standard number PN-EN ISO 12100-1+Ap1+A1 PN-EN ISO 12100-2+A1 PN-EN ISO 14121-1 PN-EN ISO 13857 2005/2006/2009 2005/2009 2008 2010 Date of issue and the technology of performing the exchangers recognized with the documents listed below: The recognition protocol in accordance with PN-EN 13134:2004 Qualification protocol in accordance with: PN-EN ISO 15613:2005(U) PN-EN ISO 15614-8:2005 BPAR Nr IS/ZT/113; -114; 115/05 z dn 10.10.2005 WPQR Nr IS/ZT/105 112; -122; -123/05 z dn. 14.11.2005 issued by the Institute of Welding in Gliwice, Identification number 1405 The EC declaration of conformity loses its validity if the heating-cooling apparatuses are changed or reconstructed without our consent. Year of marking : 2012 manager of AKW department Ryki...... /Date of issue/ M.A. eng. Adam Filipek 12

IV. TERMS OF GUARANTEE 1. JUWENT Szymañski, Nowakowski Spó³ka jawna with its seat in Ryki at Lubelska street 31, hereinafter referred to as the Guarantor, hereby grants to the Purchaser, a guarantee of correct performance for the device with a reservation of the requirement that exploitation will be consistent with the terms and conditions defined in the operation manuals and under the terms and conditions provided below. 2. The guarantee shall be granted for the period of 24 months, counting from the purchase date indicated on the guarantee card with a possibility to extend it on special terms, in accordance with a separate agreement and defined in Special Guarantee Conditions. 3. The guarantee covers the removal of technical defects of the device caused as a result of its exploitation in accordance with the operation manuals, disclosed in the guarantee period. The provisions of the guarantee shall be obligatory within the territory of the Republic of Poland. 4. For the guarantee granted, the Guarantor does not bear any responsibility for the loss of expected benefits and the costs incurred by the Purchaser resulting from temporary inability to use the device. 5. It is necessary to provide the Guarantor with a device subject to complaint with a guarantee card in order to realize the rights of the Purchaser resulting from the guarantee. 6. The complainant shall deliver the device subject to complaint in an original, factory packaging, and in case of no packaging the device subject to complaint should be delivered for repair by the Purchaser in the manner which assures proper transport. The risk of accidental damage of the device during the transport encumbers always the party which sends the shipment. 7. The defects disclosed in the guarantee periods shall be removed by the Guarantor free of charge. The selection of the realization method of liabilities resulting from the guarantee granted to the Purchaser shall be the responsibility of the Guarantor, who may remove the defect through repair or replacing a damaged subassembly or replacing the device itself, alternatively. The device or /and defective subassemblies withdrawn from exploitation shall become the property of the Guarantor. 8. The guarantee shall be extended with the period in which the Purchaser was deprived of a possibility to use the device. 9. The Guarantor shall make attempts so that the repair could be conducted without unnecessary delay, within 14 working days of delivering the device. In justified cases, which would be reported by the Guarantor to the Purchaser, the date may be extended, e.g. by the supply import duration or in the event when there is a necessity to conduct expertise or laboratory tests in specialized facilities. 10. The Guarantor shall be exclusively responsible for the defects in the device sold. They do not cover the defects caused after its sale for other reasons and in particular: a) mechanical damage (including also micro-particles occurring in the working environment of the device), thermal, chemical and of occidental nature of caused by atmospheric factors, b) damages caused as a result of non-compliance with typical exploitation principles of the device or those defined in the operation manuals, or concerning assembly or using the device inconsistent with the purpose and other damages caused by action or omission of the Purchaser, c) damages resulting from defective operation of the system, in which the device was constructed or was exploited, d) damages caused as a result of failing to perform the activities, which had to be done by the Purchaser in accordance with operation manuals e.g. periodical cleaning, maintenance, adjustment, etc. e) damages resulted from using materials or parts being subject to normal, exploitation wear out other than those recommended by the Guarantor in the operation manuals. f) damages being the consequence of using electrical supply of the device (or the system in which the device functions) inconsistent with the standard and in case also of supplying the device with water, the damages being the consequence of using water (supplying water and/or boiler water) with other parameters than those foreseen in the obligatory standard (PN-93/C- 04607) g) damages caused as a result of operation and/or maintenance in the manner which is inconsistent with the operation manuals and/or by the unauthorized persons. 11. The guarantee does not cover either : a) activities performed by the Purchaser in accordance with the recommendations contained in the operation manuals of the device within normal maintenance and overhauls, b) costs of trip and service of the Guarantor or the entity delegated thereby in the event when the guarantee call turns out groundless. 12. A note is prepared by the trained employee in the Card of Overhauls and Maintenance of the device is a confirmation that the dates are kept and the scope of activities foreseen for the service of the operation is performed. 13. The Guarantor does not bear any responsibility for the damages suffered by the Purchaser or other persons caused by a motion of the device as a result of failing to comply with the terms and conditions provided above by the Purchaser. 14. In case of performing the service by the Guarantor in the place of mounting the device, the Purchaser shall grant free access to the rooms, in which the devices are placed. 15. In the event of the devices mounted on the height which allows for the access from the surface of the floor, the Purchaser shall assure scaffolding or mobile lifting and vertical transport of the device, consistent with HSE provisions. 16. Disassembly of the device from the electrical and/or plumbing system shall be conducted by the Purchaser. 17. The complaints should be lodged at the Guarantor's address in writing / by fax / e-mail on the service report form. 18. The Guarantor shall refuse to perform guarantee activities (periodical service or the repair) in case of failing to pay the price to the Guarantor for the device or for an earlier service performed. DATE OF SALE STAMP AND SIGNATURE Special Guarantee Terms and Conditions: Extension of the guarantee period to... months. Others: SIGNATURE AND STAMP 13

TYPE OF THE DEVICE: MANUCTURING NUMBER: YEAR OF MANUFACTURE: V. DEVICE START-UP REPORT Date of startup Contractor of the start-up stamp / surname and signature Current of the motor [A] Representative of the user stamp / surname and signature Notes VI. OVERHAULS AND MAINTENANCE SHEET* Date of overhaul Contractor of the overhaul stamp / surname and signature Scope of service activities Notes * Overhaul of the device in accordance with the chapter Repair and Maintenance in the Operation Manuals 14

Date: VII. SERVICE REQUEST FORM WARRANTY POST-WARRANTY PAID Device user (name) Contact person User address Phone number, fax number and e-mail Device type Factory number Year of production Startup performed by Defect description: NOTE: AFTER COPYING AND FILLING IN SEND THE FORM BY FAX OR E-MAIL WITH A COPY OF THE STARTUP REPORT ENCLOSED JUWENT accepts only complete and legible forms. Should an unjustified complaint be submitted, the person submitting shall be charged with the service costs. Warranty issue date... Order number... (stamp with the company's name) 15

VIII.LIST OF SUBASSEMBLIES INSTALLED IN THE DEVICE No Name of the subassembly *) 1 2 3 Axial fan with tri-phase motor Plate II-row heat exchanger Plate III-row heat exchanger *) mark proper field corresponding to the variant of equipment 16