TECHNICAL SPECIFICATIONS

Similar documents
TECHNICAL SPECIFICATIONS

P8SE Series. 14 SEER, Single Phase Packaged Air Conditioner TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 3, 4, 5 Ton Units

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS

DT5BD Series High Efficiency Heat Pumps 13+ SEER Residential System Ton Capacity

TECHNICAL SPECIFICATIONS

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

PROVIDING HIGH EFFICIENCY AND WORRY-FREE PERFORMANCE

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

RGE 13 A T - 1 A

TECHNICAL SPECIFICATIONS B6VMMX

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

48GS(N) STANDARD EFFICIENCY 48GX(N) HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING ELECTRIC COOLING UNITS

13 GEP A L P - 1 A

SPLIT SYSTEM AIR CONDITIONERS, HEAT PUMPS AND PACKAGED SYSTEM PRODUCTS Built Exclusively for Manufactured Housing

JS5BD-K(A,B) Series High Efficiency Air Conditioner 13+ SEER Residential System Ton Capacity

48GS HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS

50TM TFF COMBINATION HEATING/COOLING UNITS

ACNF Series. Ceiling-Mount Air Handlers 1½ to 2½ Tons

50TM COMBINATION HEATING/COOLING UNITS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Condensing Units & Air Handlers

HEATING & COOLING SPLIT SYSTEM HEAT PUMP & AIR CONDITIONER 14 SEER INTERTHERM SERIES

PGF SERIES 7-1/2 Ton. Belt Drive CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT

SPLIT SYSTEM AIR CONDITIONERS, HEAT PUMPS AND PACKAGED SYSTEMS

Product Data. Fig. 1 - Unit 50VR -A

13 SEER CONDENSING UNITS & AIR HANDLERS

PROVIDING EXTRA-HIGH EFFICIENCY AND WORRY-FREE PERFORMANCE

Weathermaster Series 48HJ004, 005, 006, 007, 008, 009, 012 & 014 COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS

AND WORRY-FREE PERFORMANCE

36,000-62,000 BTUH Nominal Capacity

RSG16**S1M. Split System Air Conditioner 16 SEER

Product Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons

TECHNICAL SPECIFICATIONS

High Heat COP. High/Low Stage

PC SERIES 50 Hertz PRODUCT SPECIFICATIONS. Self-Contained Packaged Air Conditioners. 4 and 5 Ton [14.1 kw to 17.6 kw]

50HJQ004, 005, 006, 007, 008 & 012 SINGLE-PACKAGE HIGH-EFFICIENCY HEAT PUMP UNITS WITH FIELD-INSTALLED ELECTRIC HEAT

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION

Ruud Achiever Series Dedicated Horizontal Package Heat Pump

Ruud Achiever Series Dedicated Horizontal Package Heat Pump

50HS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP UNITS W/OPTIONAL ELECTRIC HEAT

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

TECHNICAL GUIDE MODELS: MV MODULAR VARIABLE SPEED AIR HANDLERS FOR USE WITH SPLIT SYSTEM COOLING & HEAT PUMP DESCRIPTION FEATURES

48TM GAS HEATING/ELECTRIC COOLING UNITS

LIGHT COMMERCIAL. Packaged Units and Split Systems APPLICATIONS: OFFICES RETAIL STORES RESTAURANTS CLINICS

T-SERIES SPLIT SYSTEM UNITS R-410A - 60 HZ. EER up to to 20 Tons Cooling Capacity - 71,000 to 236,000 Btuh AIR CONDITIONERS TS

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

15 SEER SINGLE- PACKAGED HEAT PUMP SYSTEM WITH PURON

Whirlpool Split System 13 SEER Air Conditioner W2C3. Features

PAR5. Product Specifications

4HP15L PRODUCT SPECIFICATIONS HIGH EFFICIENCY SPLIT HEAT PUMP SYSTEM UP TO 15 SEER & 9.0 HSPF COILS COMPONENTS COMPRESSOR WARRANTY CABINET DESIGN

Corp L2 Revised

Product Data. Features/Benefits. 50HS Single-Package Heat Pump Units 50 Hz

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

seer 4HP16LT Split System Enhanced Heat Pump Features and Benefits WARRANTY

Unit Features & Benefits RQPM/RQRM Series

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

AEPF. 1½ to 5 Tons. Contents Nomenclature... 2 Product Specifications... 3 Dimensions... 4 Wiring Diagram... 6 Accessories... 7

AC, HP and Air Handler Units Up to 20 Tons. Commercial Split Systems. Reliable, cost-effective and servicefriendly split systems inside and out

HEAT EXCHANGER Aluminized serpentine clamshell heat exchanger provides corrosion resistance for longer life and efficient heat transfer.

T P A 120 S 4 S N 1 Y

TECHNICAL GUIDE VARIABLE SPEED AIR HANDLERS DESCRIPTION FEATURES Rev. A (0105)


072, 090, 120, 180 & 240 MODELS C SERIES CONDENSING UNITS P SERIES HEAT PUMPS

UNIT INFORMATION. Corp L7. Gauge Manifold Attachment... Page 30 Parts Arrangement... Page 8

BCE4 PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER WITH VARIABLE SPEED APPLICATION INSTALLATION CABINET COMPONENTS CONTROLS WARRANTY

50Hz AC, HP and Air Handler Units Up to 70 kw. Commercial Split Systems. Reliable, cost-effective and servicefriendly split systems inside and out

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

Bosch BVA Series Air Handler

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

Ruud Standard Efficiency Air Handler

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.

607C- -A PREFERREDt SINGLE-PACKAGED HEAT PUMP SYSTEM WITH PURONR (R-410A) REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS (SIZES 24-60)

PGB SERIES 3thru5Ton 10 SEER CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT

TECHNICAL SPECIFICATIONS

48SS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS

Performance and rugged durability. Commercial Split Systems Up to 20-Ton TSA/TPA Models

LRP14HP. Residential - R-410A L RP 14 HP 36 P A MODEL NUMBER IDENTIFICATION. Bulletin No November 2016 Supersedes October 2016

48TF GAS HEATING/ ELECTRIC COOLING UNITS

50VT--C Comfort 14 SEER Single--Packaged Heat Pump System with Puron

15A 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

NH4H4. Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT

Model 655A Sizes

T-CLASS Commercial Split Systems Up to 20-Ton TSA/TPA Models

PAJ3. Product Specifications

HIGH EFFICIENCY AIR HANDLER

WAHL A Product Specifications

WCH5**4. Product Specifications

Product Data. Fig. 1 - Unit 50VG -A

Commercial High-Efficiency Condensing Units

HIGH EFFICIENCY AIR HANDLER

Product Data. Fig. 1 - Unit 50EZ -A

SPLIT-SYSTEM HEAT PUMPS 50 AND 60 HZ DESCRIPTION

DCC Commercial. Submittal Data Form. 7½ - 12½ Ton Packaged Air Conditioners Up to 11.3 EER Cooling Capacity: 88, ,000 BTU/h

Rheem Air Handlers. RHML- Series X-13 (ECM) Motor

Ruud Standard Efficiency Air Handler

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

Transcription:

TM TECHNICAL SPECIFICATIONS Model Q4SD Series M120 Product Line Single Packaged Heat Pump 13 SEER 3-5 Ton Units

12 YEAR ALL PARTS WARRANTY This product offers a 1 Year Dependability Promise to replace the unit if the compressor fails in the first year of operation, to the original owner. All split system products must be installed with a matched indoor air handler or indoor coil to qualify. Product registration required for 12-year All Parts Warranty and Dependability Promise within a limited period of time after the installation. See current warranty document for details. This can be viewed at www.maytaghvac.com or ask your sales representative. The Q4 Series single packaged heat pumps are high efficiency self contained cooling and heating units that can be installed on a roof or on a slab. The convertible unit design makes installations simple in all applications. Units are ETL and ETLc listed. Features and Benefits Compact Footprint/Low Profile Easy to handle and transport. Five Minute Restart Time Delay When the unit shuts down, a five minute delay keeps the unit from restarting, eliminating the highest cause for compressor failure. Heavy-, Full Perimeter Base Rails Facilitates forklift handling and curb mounting. Convertible Air Delivery Horizontal or downflow to accommodate rooftop or horizontal application. Galvanized Steel Cabinet Polyurethane finish provides 950 hours salt spray protection. Plastic Coated Coil Guard and Mesh Hail Guard Will never rust and protects the coil from being damaged by balls, lawnmowers, hail etc. Externally Accessible Service Ports Quick access to refrigerant system without disrupting operation. Access to Controls and Major Components Easy in and out service. Corrosion-Resistant Drain Pan Quickly drains away evaporator condensate. Service Access Panels Allows easy access to all major components and the compressor. Designed to make servicing easier for the Contractor. Easy to Install Electric heat strip provides up to 20 KW of heat output. Proven, Industry Standard Components Easier service and availability. Quiet Operation and Low Vibration 20" fan blade combined with custom venturi condenser fan. Accessories Roof curbs, and more. Time / Temperature Defrost A reliable, industry standard control offers various time settings to meet any type climate.

IDENTIFICATION CODE Q 4 S D 024 K Packaged Heat Pump Series Square Duct Connections D = 13 SEER Nominal Capacity x 1000 Btu Electrical Code K = 208/230-60-1 SPECIFICATIONS Model Number BLOWER PERFORMANCE Q4SD 036 048 060 Performance Capacity - Heating BTUH 33,500 45,000 51,000 Efficiency - HSPF 7.7 7.7 7.7 Capacity - Cooling BTUH 34,800 46,000 55,500 Efficiency - SEER 13.00 13.00 13.00 EER (Btuh/watt) 11.0 11.0 11.0 Electric Rating - 60Hz (a) Phase 1 1 1 Operating Voltage Range 187-253 187-253 187-253 Min. Circuit Ampacity (a) 27.7 36.7 42.5 Field Wire Size - AWG (a) 10 8 6 Total Unit - Amps 23.2 30.8 35.5 Compressor Data Volts 208-230 208-230 208-230 Rated Load Amps 17.9 23.6 28.0 Lock Rotor Amps 88 137 169 Indoor Blower Type Fixed Torque Fixed Torque Fixed Torque Motor HP-RPM Range 1/2-1100 3/4-1400 3/4-1600 Motor - Amps 4.1 6.0 6.0 Outdoor Fan Motor - HP / RPM 1/4-1100 1/4-1100 1/3-1000 Motor - Amps 1.2 1.2 1.5 Fan Diameter / CFM 20 / 3800 20 / 3800 20 / 4000 Refrigerant Charge - Oz. 127 293 224 Net Weight lbs. 460 570 580 Shipping weight lbs. 470 580 590 Model Number Q4SD 036 048 060 * * * * * * External Static Pressure Drop-inches water column Speed 0.1 0.2 0.3 0.4 0.5 0.6 Tap T1 1150 1050 1000 950 850 780 Tap T2 1230 1190 1120 1080 1000 950 Tap T3 1400 1350 1200 1150 1080 1030 Tap T4 1600 1500 1400 1300 1200 1050 Tap T5 1700 1650 1600 1565 1530 1480 Tap T1 1515 1450 1380 1350 1300 1250 Tap T2 1580 1520 1460 1400 1360 1300 Tap T3 1740 1690 1650 1600 1540 1500 Tap T4 1960 1910 1840 1820 1780 1740 Tap T5 2090 2050 2010 1975 1940 1900 Tap T1 1515 1450 1380 1350 1300 1250 Tap T2 1580 1520 1460 1400 1360 1300 Tap T3 1740 1690 1650 1600 1540 1500 Tap T4 1960 1910 1840 1820 1780 1740 Tap T5 2090 2050 2010 1975 1940 1900 * Denotes factory set cooling and heat pump speed ** Denotes factory set electric heating speed 3

DIMENSIONS 24.9 3/4" NPT Female Drain Connector DOWNFLOW SUPPLY DUCT OPENING CG 47.5 13.5 16.0 13.5 16.0 B 13.3 12.0 12.0 A 23.5 DOWNFLOW RETURN DUCT OPENING Top View Model Number Q4SD Unit Weight Center of Gravity A B Height (in inches) with base rails C without base rails 036 460 28.0 25.5 35.0 35.3 048 570 29.5 26.0 43.0 39.3 060 580 29.5 26.0 43.0 39.3 4

DIMENSIONS continued 1.8 1.75 Ø Power Entry (Capped) 1.25 Ø Power Entry 30.0 0.88 Ø Control Wiring Entry 27.2 23.6 4.00 Side View 5.0 4.0 C SUPPLY 13.5 RETURN CONDENSING COIL 16.0 8 16.0 13.5 14.7 13.45 11.75 22.75 55.8 Back (Duct) View 5

ELECTRICAL DATA Model Number Heater Installed Nom. KW Minimum Circuit Amp. Single Supply Circuit Option (60 C Cu) (75 C Cu) (90 C Cu) Maximum Overcurrent Rating* Minimum Circuit Amp. Multiple Supply Circuit Option Circuit A (Compressor & Fan) Circuit B (Blower & Heater) Circuit C (Heater Only) (60 C Cu) (75 C Cu) (90 C Cu) Q4SD-X36K 0 27.9 10 10 10 45 - - - - - - - - - - - - - - - Maximum Overcurrent Rating* 5 52.9 6 6 8 60 23.6 10 10 10 40 29.3 10 10 10 30 - - - - - 8 67.5 4 4 6 70 23.6 10 10 10 40 43.7 6 8 8 45 - - - - - 10 77.9 3 4 4 80 23.6 10 10 10 40 54.3 6 6 8 60 - - - - - 15 102.9 1 2 3 110 23.6 10 10 10 40 54.3 6 6 8 60 25 10 10 10 30 20 127.9 00 1 2 150 23.6 10 10 10 40 54.3 6 6 8 60 50 6 8 8 60 Q4SD-X48K 0 36.7 8 8 8 60 - - - - - - - - - - - - - - - 5 61.7 4 6 6 80 30.7 8 8 8 50 31.2 8 8 8 35 - - - - - 8 76.3 3 4 4 90 30.7 8 8 8 50 45.6 6 8 8 50 - - - - - 10 86.7 2 3 4 100 30.7 8 8 8 50 56.8 4 6 6 60 - - - - - 15 111.7 0 2 2 125 30.7 8 8 8 50 56.8 4 6 6 60 25 10 10 10 30 20 136.7 00 0 1 150 30.7 8 8 8 50 56.8 4 6 6 60 50 6 8 8 60 Q4SD-X60K 0 42.5 6 8 8 70 - - - - - - - - - - - - - - - 5 67.5 4 4 6 90 36.5 8 8 8 60 31.8 8 8 8 35 - - - - - 8 82.1 3 4 4 100 36.5 8 8 8 60 46.4 6 8 8 50 - - - - - 10 92.5 2 3 4 110 36.5 8 8 8 60 56.8 4 6 8 60 - - - - - 15 117.5 0 1 2 125 36.5 8 8 8 60 56.8 4 6 6 60 25 10 10 10 30 20 142.5 00 0 1 150 36.5 8 8 8 60 56.8 4 6 6 60 50 6 8 8 60 Minimum Circuit Amp. (60 C Cu) (75 C Cu) (90 C Cu) Maximum Overcurrent Rating* Minimum Circuit Amp. (60 C Cu) (75 C Cu) (90 C Cu) Maximum Overcurrent Rating* *When overcurrent rating exceeds 60, internal circuit breakers must be installed in addition to branch circuit protection at distribution panel. HEATER APPLICATION MATRIX Model Number H3HK-005H-01 H3HK-008H-01 H3HK-010H-01 H3HK-015H-01 H3HK-020H-01 H3HK-015H-21 H3HK-020H-21 917166 917167 917168 917169 917170 917172 917173 Q4S( )-036K X X X(2) X(2) NA X NA Q4S( )-048K X(2) X(2) X(2) X(3) X(3) X(1) X(1) Q4S( )-060K X(2) X(2) X(2) X(3) X(3) X(1) X(1) NA = Not Applicable. ( ) = Number of internal circuit breaker kits required. IDENTIFICATION CODE Heater 3 - Q4 Pkgd. Units H 3 HK 008 - H 0 1 Heater Kit Electric Heater KW Electric Code H=240-1-60 No. of Breakers Stages

ACCESSORIES Description Part Number Roof Curb (8 ) 547830 Roof Curb (14 ) 547831 Roof Curb (18 ) 547850 Roof Curb (24 ) 547851 Filter Rack, All Downflow Applications (not required with economizer) 547885 Filter Kit (not required with economizer) for Horizontal Applications Q4SA 030, 036, 042 547887 Filter Kit (not required with economizer) for Horizontal Applications Q4SA 048-060 547888 Universal Hard Start Kit 912933 Low Pressure Switch Kit 913551 High Pressure Switch Kit 913550 Low Ambient Kit 913549A P-Trap Kit 913810 Outdoor Thermostat Kit 913852

CERTIFICATION APPLIES ONLY WHEN THE COMPLETE SYSTEM IS LISTED WITH ARI Before purchasing this appliance, read important energy cost and efficiency information available from your retailer. Specifications and illustrations subject to change without notice and without incurring obligations. Maytag is a registered trademark of the Maytag Corporation and is used under license. 994B-0207 (Replaces 994B-0306) Printed in U.S.A. (02/07)