FV-11VQL6. Thank you for purchasing this Panasonic product Back cover FV-15VQL6

Similar documents
CONTENTS DESCRIPTION UNPACKING DIMENSIONS

CONTENTS WIRING DIAGRAM

Ventilating Fan FV-05VFL2 FV-08VFL2 FV-11VFL

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

VENTILATION FAN WITH BLUETOOTH SPEAKER

VENTILATION FAN. MFG Model : VFB80HLED2/VFB080C4L2 /VFB080C4LED2/ VFB100HLED2/VFB100C4LED1 READ AND SAVE THESE INSTRUCTIONS

Ventilation Fan Model VFB24ACTH VFB24ADTH VFB24AXTH

Blueair C User Manual

GARAGE HEATER WITH REMOTE INSTRUCTION MANUAL MODEL: HA24-100E HA24-150E. Figure 1

HUMIDITY SENSING BATH FAN

VENTILATION FAN / LED LIGHT

Universal Fan and Light Remote Control

The Digital Door Viewer! User Manual. Motion Activated Sensor MAS 100

VENTILATION FAN READ AND SAVE THESE INSTRUCTIONS. MODEL Pro200/Pro300 TABLE OF CONTENTS. Package Contents. General Safety Information

Clean Base Automatic Dirt Disposal. For Roomba i Series Robot Vacuums. Owner s Guide

Personal Ultrasonic Humidifier. FALLH-01 series

VENTILATION FAN READ AND SAVE THESE INSTRUCTIONS MODEL 50F / 70F / 70HS TABLE OF CONTENTS. Package Contents 2. General Safety Information 3

180 Degree Ceiling Mounted Occupancy Sensors

BATH FAN / LED LIGHT READ AND SAVE THESE INSTRUCTIONS MODEL GBR100LED-DECOR TABLE OF CONTENTS. Package Contents 2. General Safety Information 3

Installation Instructions Exhaust Fan With Light

VENTILATION FAN / LED LIGHT / LED NIGHT LIGHT

User s Manual WS-3230SS WS-3236SS WS-3242SS WS-3248SS

LED CEILING LIGHT WITH MOTION SENSOR AND REMOTE. ITM. / ART Model: LM56123 CARE & USE INSTRUCTIONS

Wireless Home Appliance Timer Remote Control Kit

Blueair Classic. User Manual - 500/600 series

READ AND SAVE THESE INSTRUCTIONS GENERAL SAFETY INFORMATION

Blueair Classic. User Manual series

Ionic Breeze QUADRA Silent Air Purifier. SI637 SI697 Instructions

IMPORTANT INSTRUCTIONS - OPERATING MANUAL

Ultrasonic Wall Switch Occupancy Sensor Single Circuit

IMPORTANT SAFETY INFORMATION! WARNING ALWAYS keep electric cords, home furnishings, drapes, clothing, papers, or other combustibles at least 3 feet (0

Installation and Operation Guide

Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation.

Homeowner s Installation Instructions & Operating Manual

Table of Contents. What s in the Box... 3 Power Requirements... 4 Quick Setup... 5 Lighting Guide With Ring, you re Always home.

Welcome. Sensor. 1 (844) LIGHTCLOUD Custom manufactured in China RAB Lighting, Inc 170 Ludlow Avenue Northvale, NJ 07647

Passive Infrared (PIR) Wall Switch Occupancy Sensor Dual Circuit

breeze easytm model # F100-1W

READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AN

SAVE THESE INSTRUCTIONS

Little Anne. Important Product Information

Homeowner s Installation Instructions & Operating Manual

TABLE OF CONTENTS. Box Contents...3. Quick Start Instructions Important Information Intended Use Meat Probe Use...

Installer Guide smart connect

Dahua HD Mini IR Waterproof Bullet Network Camera. Quick Start Guide

DEHUMIDIFIER. User Manual 50BT, 70BT

EW 40 Wireless Fan Control

FE1 Series Ventilation Fans 2007 Soleus Air International. Soleus Air Ultra Quiet Ventilation Fan

OPERATING MANUAL CUSTOMER SERVICE NO

Homeowner s Installation Instructions & Operating Manual

NXSMP-LMI LOW MOUNT INDOOR SENSOR MODULE

Installer Guide smart connect

Bathroom Exhaust Fan/Fluorescent Light Combination

MILLA ELECTRIC FIREPLACE

Towel Warmer MAKE EVERYDAY A SPA DAY

User s Manual WS-69TB30 / WS-69TB36 (22 ) WS-69TB42 / WS-69TB48 (22 ) WS-69TS30 / WS-69TS36 (18 ) WS-69TS42 / WS-69TS48 (18 )

VENTILATION FAN WITH LED LIGHT AND HEATER MODEL RAD110LED

Homeowner s Installation Instructions & Operating Manual

e Bath Fan with Light User s Guide

With Remote Control. English

Operation and Maintenance Manual

TABLE OF CONTENTS. Box Contents...3. Quick Start Instructions Important Information Intended Use Meat Probe Use...

Easy installation in both new construction and retrofit RN80L RN110L READ AND SAVE THESE INSTRUCTIONS INSTALLATION GUIDE

programmable control model installation and setup guide M /11/ Hunter Fan Company

Packaged Heat Pumps. Owner s Guide to Operating and Maintaining Your Heat Pump

e Bath Fan with Light User s Guide

ShockLink. Important Product Information.

Electric Wall/Ceiling Projection Screen

Integrated Ventilation System

AGES. instruction manual DAISY BLOOM PROJECTION ALARM CLOCK

COMBINATION ELECTRIC FIREPLACE/HEATER Model #FP23-1A-AKM

Portable Air Conditioner User Manual

Operating Instructions & Parts Manual. Silent Low-Profile Ceiling Fans. Models 3DPE2A, 3DPE3A, 1UBH6B, 1UBH7B, 1UBH8A, 5AE68B, 5AE69A

MAJIK ENGLISH 11/20/02 11:30 AM Page 1 M A J I K O W N E R S M A N U A L

VENTILATION FAN WITH LIGHT AND HEATER

CONNEX Smart Thermostat CST R00

User s Manual WS-4830SS WS-4836SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

BBQ THERMOMETER DESCRIPTION OF PARTS. MODEL NO.: AW129/AWR129 Instruction Manual

Towel Warmer. Luxurious warmth for towels, robes and blankets

TABLE OF CONTENTS. Box Contents...3. Quick Start Instructions Important Information Enhance Your Assembly Experience. Intended Use...

Safety Instructions. Be sure to observe the following instructions when using the device.

Please Read and Save These Instructions Safety Information

Table of Contents. Important Safety Instructions. WARNING: If the instructions contained in this manual are not followed

e Heater/Exhaust Fan/Light User s Guide

SOOTHING COOL MIST AROMA DIFFUSER

INSTRUCTION MANUAL Z-WAVE DIMMER 12387

Operator s Manual. Mirage. Buffet Induction Warmers

User s Manual WS-63TB36SS WS-63TB42SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

Micro-Computer Induction Cooktop SR-1885SS

Operation Manual RANGE HOOD

ULTRA SILENT VENTILATION FAN READ AND SAVE THESE INSTRUCTIONS WARNING CLEANING & MAINTENANCE OPERATION CAUTION!

Fig. 1 - Unit PHD4 and WPH4

Getting Started with

e Bath Fan with Light User s Guide

Ultrasonic Aromatherapy Diffuser with Color Changing LED Lights Instruction Manual and Warranty Information - Read and Save These Instructions.

Table of Contents What to Expect with Your Installation. Top Housing. Ceiling Plate. Tools Needed.

Wireless Driveway and Intruder Alert

Dimmable LED Retrofit Kit

User s Manual WS-62N30SS WS-62N36SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

Transcription:

FV-08VQL6 FV-15VQL6 FV-11VQL6 2-3 5 5 6-8 FV-08VQL6 FV-11VQL6 11 Back cover Back cover Back cover FV-15VQL6 Thank you for purchasing this Panasonic product.

For Your Safety To reduce the risk of injury, loss of life, electric shock, fire, malfunction, and damage to equipment or pro always observe the following safety precautions. Explanation of symbol word panels The following symbol word panels are used to classify and describe the level of hazard, injury, and property damage caused when the denotation is disregarded and improper use is performed. WARNING Denotes a potential hazard that could result in serious injury or death. Denotes a hazard that could result in minor injury. The following symbols are used to classify and describe the type of instructions to be observed. This symbol is used to alert users to a specific operating procedure that must be followed in order to operate the unit safely. This symbol is used to alert users to a specific operating procedure that must not be performed. The symbol is used to alert users not to disassemble the equipment for reconstruction in order to reduce the risk of fire and electric shock. This symbol is used to alert users to make sure of grounding when using the equipment with the grounding terminal. WARNING To reduce the risk of fire, electric shock or injury to persons, observe the following : Use this unit only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer. Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel. Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. Ducted fans must always be vented to the outdoors. If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application and be connected to a GFCI(Ground Fault Circuit Interrupter) - protected branch circuit. These models are UL listed for tub and shower enclosures. 2

WARNING USA only: This product has two fluorescent lamps that contain mercury. Disposal may be regulated in your community due to environmental considerations. For disposal or recycling information, please contact your local authorities or visit Panasonic website: http://www.panasonic.com/environmental or call 1-888-769-0149. Canada only: Not to be installed in a ceiling thermally insulated to a value greater than R40. Do not disassemble the unit for reconstruction. It may cause fire or electric shock. Ceiling joist must be subjected to static load more than five times the weight of the product. Do not install with a method which is not approved in the instrucions. This product must be properly grounded. Do not install this ventilating fan where interior room temperature may exceed 104 F(40 C). Make sure that the electric service supply voltage is AC 120V, 60Hz. Follow all local electrical and safety codes, as well as the National Electrical Code (NEC) and the Occupation Safety and Health Act (OSHA). Always disconnect the power source before working on or near the fan, motor, light fixture or junction box. Protect the supply wiring from sharp edges, oil, grease, hot surfaces, chemicals or other objects. Do not kink the supply wiring. Adaptor Provide make up air for proper ventilation. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors. Do not install the unit where ducts are configured as shown in Fig.A. Not for use in cooking area. (Fig.B) The special-purpose or dedicated parts, such as mounting fixtures, must be used if such parts are provided. 3

The lighting unit is an energy-saving, lighting device that uses two 13W fluorescent lamps and produces almost the same illumination as a standard 100W incandescent lamp. FCC Note: This equipment contains two self-ballast fluorescent lamp and is in compliance with Part 18 of the FCC Rules as consumer RF lighting device. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning this product on and off, the user is encouraged to try to correct the interference by one of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect equipment into outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/tv technician for help. Warning: This equipment must be installed in accordance with installation instructions. Also, any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. This device complies with Part 18 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Responsible Party: Panasonic Corporation of North America One Panasonic Way, Secaucus, New Jersey 07094 Customer Support: 1-866-292-7292 13W Fluorescent lamp 2 4

FV-08VQL6 FV-11VQL6 4 3/5 (116) 10 1/4 (260) 4 3/5 (116) FV-15VQL6 10 1/4 (260) Wiring diagram Fan body Junction box Fluorescent lamp (Self-ballasted) Black White Live Neutral (LIGHT) Night lamp Black Live (N.LIGHT) Capacitor (Power supply) AC120V 60Hz Motor (Fuse in motor) Fuse type: FV-08VQL6: ( 114 c) Impedance - protected FV-11VQL6: ( 114 c) Impedance - protected FV-15VQL6: ( 134 c ) Thermally protected White Black Green Earth ground Neutral Live (Earth ground) (VENT.) 5

Fig.1 Fig.2 6

6. Refer to wiring diagram. (Wiring detail please refer to the wiring diagram on page 5.) Fig.3 (Night lamp) Fig.4 Fig.5 8. Remove screw (M4X8). Remove light cover. (Fig.6) Fig.6 7

9. Install the night lamp and fluorescent lamps. (Fig.7) 3 Fig.7 10. Install light cover. (Fig.8) Secure screw (M4X8) Fig.8 (Fig.9) 11. (Fig.9) 12. (Fig.9, Fig.10) Fig.9 Fig.10 8

Fig.11 (Fig.11, Fig.12) (Fig.13) Fig.12 12 (page 7, page 8) Fig.13 9

(Fig.14) 12 (page 7, page 8) Fig.14 WARNING Fig.15 1.Clean grille. (Don t put into hot water. Use non-abrasive kitchen detergent, wipe dry with clean cloth) (Fig.15) Fig.16 (Fig.16) (Fig.17) Fig.17 10

WARNING Fig.18 Remove dust and dirt from light cover and lens, before replace the lamps. (Fig.18) Fig.19. Fig.19. Fig.19 Lens 3. Replace the fluorescent lamps (Maxlite MLS13GU35 13W) as shown in step 1 and step 2 of Fig.20. 4. Replace the 4W night lamp. (Fig. 20) Install the fluorescent lamps (Maxlite MLS13GU35 13W) as shown in step 2 and step 3 of Fig.7 (page 8). 3 5. Install light cover. (Fig.8 of page 8) Fig.20 11

(Fig.21) Fig.21 FV-08VQL6 26 FV-11VQL6 26 FV-15VQL6 26 10.6 (4.8) 10.6 (4.8) 11.9 (5.4) Panasonic corporation 2013 T0313-0 08VQL6200