TECHNICAL DOCUMENTATION DTR AIR WATER HEATERS IN STEEL CASING S SERIES

Similar documents
TECHNICAL DOCUMENTATION DTR AIR WATER HEATERS IN STEEL CASING S SERIES

Technical documentation DTR AIR WATER HEATERS IN EPP CASING HC-3S SERIES

Technical documentation DTR

Technical documentation

Technical documentation: S1 S2 S3 S4

Technical documentation DTR. Farmer HCF in EPP casing

Technical documentaton DTR. Farmer

Technical documentaton DTR. Farmer

Technical documentation WATER HEATED AIR CURTAIN MODELS: REVENTON GROUP AERIS 100WN-1P REVENTON GROUP AERIS 150WN-1P REVENTON GROUP AERIS 200WN-1P

PRICE LIST VALID FROM 1st October 2017

Reventon Group [Ltd.] 3B Montażowa Street, Bielsko-Biała, Poland VAT ID tel.

HEATING AND COOLING DEVICE AGC

INSTALLATION OPERATION & MAINTENANCE INSTRUCTION HEAT RECOVERY UNITS VHR MODELS

HyBo - Hydraulic Interface Unit AMBIENT HEATING AND DOMESTIC HOT WATER PRODUCTION FOR CENTRAL HEATING SYSTEM UNIT CODE EHIU1

TECHNICAL MANUAL YEFB HIGH PRESSURE DUCTED UNIT

ErP OPERATIONS MANUAL FOR AIR HEATER PROTON ECO. PROTON ECO Three-speed AC-motor

Weekly thermostat for boilers Galan - regulator for management of heating elements and circuit SolarSentinel-DBTW Users guide.

1.1 VTS: number 1 in the world pillars of success

Operating manual. Pellet boiler. Orlan Pellet ISO 9001

Installation & Operating Manual ZM kW Universal Oil Heater. ZMH Ltd t/a Z M Heaters T (0)

Fan Coil Unit 1. BOSCH Climate Fan Coil Unit

TermEfekt USER S MANUAL AIR HEATER. Model PGA 14

VMA-VMB NOVA AIR HEATERS. NoVa air heaters

No. 1 in Europe New on offer air curtain GUARD

Roof top SPACE RPC 450Z R407C M011

ErP OPERATIONS MANUAL FOR AIR HEATER PROTON AST. PROTON AST Air Heater with the anemostat

INSTALLATION OPERATION & MAINTENANCE INSTRUCTION HEAT RECOVERY UNITS VHR MODELS

ErP OPERATIONS MANUAL FOR AIR HEATER PROTON EL. PROTON EL Electric heating.

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

How to install and use your storage heater

ErP OPERATIONS MANUAL FOR AIR HEATER PROTON JET. PROTON JET Air Heater with with AirJet nozzle.

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

Fan Heaters Type TXI, WBK, WBG, Delta & VLE

Installation Operation Maintenance. Ductable water unit FWD FWD-SVX01D-E4

USERS MANUAL FOR GAS BOILERS

CNBOP-PIB Standard Fire Protection

CAW Ceiling-mounted fan heaters for hot water

WHE 2.24 / WHE 2.24 FF

Electronically controlled instantaneous water heater. MCX: 27300, and models. Installation instructions

CROWN. Boiler Co. Santa-Fe Series. Hydronic Air Handlers INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

INSTALLATION OPERATION & MAINTENANCE INSTRUCTION

Technical Guide. Installation, Operation and Care. EP E series 7 step electric boilers 26 and 42 kw

ENGINEERING SPECIFICATIONS

technical data Fan coil unit FWB small duct unit

TTK 75 ECO OPERATING MANUAL DEHUMIDIFIER TRT-BA-TTK75ECO-TC-002-EN

EBAC MODEL CD425 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

ENGINEERING SPECIFICATIONS

Roof top SPACE RPC 315Z R407C MA00

Heating, Air Conditioning, Ventilation. Отопление-Кондиционеры-Вентиляция. MTM 8-30 kw UNIVERSAL OIL HEATER OPERATING MANUAL

Air-Water heat pump Small GT

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

HIGH TEMPERATURE AIR SOURCE HEAT PUMP WATER HEATER

Air curtain.

Comfort Air Curtains with in-built dynamic advertising

Duct Heaters volts/1 phase volts/3 phase volts/3 phases volts/3 phases. Flange Type Duct Heater.

EBAC MODEL CD425 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

Gas heaters and convectors ROBUR

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

USER S MANUAL. VCU/VCUN Series CENTRIFUGAL FAN IN SCROLL CASING

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

AQUATHERM LTD INSTALLATION AND OPERATION OF ELECTRIC BOILERS

No. 1 in Europe New on offer air curtain GUARD

INSTALLATION AND MAINTENANCE MANUAL. Alcor FA

TSL hand dryer. installation + maintenance

TopVent Design Handbook

Bi2 4tubes * SLR 4T Fan coil radiator for heating and cooling at the same time. FEATURES. Cools, Dehumidifies, Heats and Filters

Electronically controlled instantaneous water heater. CEX 9-U: C models. Installation instructions

Drying Ovens Models F3 - F6 - F9

LINEAR HEAT DETECTION CABLE DURÁN-SAFE

39HX. High-efficiency dual-flow air handling unit PRODUCT SELECTION DATA. Plug & play unit (built-in control) Class A+ across entire range

The guarantee on this appliance is valid for 12 months from the first day of installation.

SG-WS type EXCHANGERS FOR TAP WATER HEATING ELECTRIC STORAGE TAP WATER HEATERS GUARANTEE CERTIFICATE. volume: 80, 100, 120, 140, 200, 300 and 380 dm 3

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

HOT TAP WATER EXCHANGER with solar pump-group ENSOL IT INSTALLATION AND OPERATION MANUAL WARRANTY CARD

80HMA. Comfort Module Range for Monobloc Heat Pumps. Nominal heating capacity 4-20 kw Nominal cooling capacity 4-20 kw. Features

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

NIBE SPLIT ACVM 270 Air/water heat pump

Drying Ovens for Fluxes Models F100 F200 - F400

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

TERM-E ELECTRIC HEATING AND VENTILATION UNITS

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

FLAME AMPLIFIER MODULE 3001

Application guide FLATAIR - FLCK/FLHK. Providing indoor climate comfort

Utopian Split A/C. Thank you for purchasing this quality Split A/C system!

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

РУКОВОДСТВО USER ПО MANUAL ЭКСПЛУАТАЦИИ CENTRIFUGAL INLINE FANS VKM / VKMZ / VC SERIES

Guide Specifications PART 1 GENERAL 1.01 SUMMARY

BSK-RPR Fire Damper. Additional operating instructions according to

FagronLab NP-1 UV. Negative pressure workbench. User Manual

DUCTIMAX 2-8 kw. Medium available static pressure ducted hydronic units. Duct unit DUCTIMAX

Product is subject to and complies with Regulation (UE) N.327/2011. cert. n Fan Coil Unit Cassette SkyStar Jumbo ECM. technical catalogue

JH Series Installation

Fan heater SWT Ceiling mounted fan heater with water heat

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

New Industrial Dual Flow Unit Coolers

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

Transcription:

TECHNICAL DOCUMENTATION DTR AIR WATER HEATERS IN STEEL CASING S SERIES

ENG Technical documentation Table of contents. INTRODUCTION. PRECAUTIONS. TRANSPORT.3 PACKAGE CONTENT.4 USE AND PRINCIPLE OF OPERATION. DEVICE CONSTRUCTION, DIMENSIONS, TECHNICAL DATA. CONSTRUCTION. DIMENSIONS.3 TECHNICAL DATA 3. ASSEMBLY 4. INSTALLATION INSTRUCTIONS. PRECAUTIONS & WARNINGS 6. CONTROLS 7. CONNECTION SCHEMES 8. TERMS OF WARRANTY 8. WARRANTY CARD 8. WARRANTY FORM 8.3 SERVICE FORM Axial blowing fan: protective grd made of steel wire galvanizes, metal blades. The moto has gor the safety degree IP 4. Rate current,4-,8a. -phase, 3-stage device. Depending on the model we offer fans with a diameter 3-4mm in S3S series. Rotating mounting bracket: Holders are additional elements to assemble the device. The are solid and durable, it is possible to assemble the device on the wall or ceiling. It is also possible to regulate the angle of slope in three (3) versions. Fixed holders: made of steel, element for mounting the device on the wall or ceiling. Solid and durable construction, possible to assemble device in parallel on the angle 6 and 4.. DIMENSIONS. INTRODUCTION Thank you very much for purchasing Reventon Group device. We would like to congratulate you on excellent choice.. PRECAUTIONS The buyer and the user of the device should read carefully the following instructions and proceed to the content recommendations. Proceeding due to S -3S the following instruction guarantees the correct usage and safety. In case of any doubts please contact the producer. The producer reserves the rights to make changes to the technical documentation without previous notice. The producer is not responsible for the damages which occur due to improper installation, not keeping the device in repair or using the device out of line. The installation should be carried out by the professional installers, who possess the qualifications to install these types of devices. The installers are responsible for making the installation as instructed in the technical data. Regulations and safety rules must be followed. During the installation, use, service and periodical inspections all regulations and safety rules must be followed. In case of unserviceable please.3 TECHNICAL DATA plug out the device and contact with the authorized person or the producer.. TRANSPORT During the acceptance of goods, it is needed to check the device to exclude any damages. During the transport, it is needed to use the proper equipment, it is necessary to carry the device by two people. In case of any damages please fill in the damage report in presence of the supplier. - Air water heater - Operation and maintenance manual and warranty card Nominal heating capacity water 9/7 C and inlet air temperature C kw Heating power range kw Maximum airow Horizontal range Number of rows in heater.4 USE AND PRINCIPLE OF OPERATION Devices Reventon Group S-3S series are used to heat spaces such as: production halls, warehouses, commercial room, service spaces, garages, workshops, greenhouses, tents, shops, malls, shopping malls and churches. Air water heaters must be connected to central heating system. Application of modern technologies in Reventon Group devices guarantees high effectiveness and comfort of the consumption. Original colors of the devices match to every interior. The device is made very precisely and will work smoothly for many years. Unit of measure TECHNICAL DATA.3 PACKAGE CONTENT S -3S m³/h 3 bieg bieg bieg m number S-3S S3-3S S4-3S 6,7 9,4, 9,3 7-7 -9 3-6-9 6 4 4 7 4 3 6 39 34 7 3,,3,9 Air temperature rise. * C 6,7 7, 48,7 9,6 C MPa 3 bieg bieg bieg A Power supply voltage V~Hz * The product has got the two years of warranty. Motor speed Rev. /min 3 bieg bieg bieg. DEVICE CONSTRUCTION, DIMENSIONS, TECHNICAL DATA Motor power W 3 bieg bieg bieg Motor IP Ferrules diameter Weight Noise,6,6,6,6,4,3,,8,3,,8,3,,84,6,4 3/ 3/ 3/ 3/ 9 8 6 4 68 7 4 4 68 7 4 4 7 9-4 4 4 4 3/4 3/4 3/4 3/4 49 4 4 48 4 3 48 4 7 7 44 kg db 3 bieg bieg bieg * Temperature rise according to parameters: water 9/7 C and inlet air temperature C. Air stators: are made of gavanized steel, powder painted in RAL 748. It is possible to adjust manually the air stators to achieve the needed direction of the airflow. Waga Heating coil: Heating coil- made of aluminim and copper. The maximum temperature of the heating factor is C; maximum pressure,6 MPa; headers diameres 3/4". Depending on the model we offer, or 3-row heating coils. S-3S dm³ Rated current Casing: made of galvanized steel casing, powder painted in RAL 9 color. S4-3S Capacity of water Maximum temperature of heating agent Maximum operating pressure. CONSTRUCTION - Casing - Air stators - Heating coil - Axial blowing fan - Rotating mounting bracket S3-3S

S-3S S-3S S-3S 9/7 8/6 7/ -, - 9,4 6,7 4,,7-9,6-6,9 4,3,8 - - 9,4 7, 4,4,9 9,44 7,9,3, 9,6 3,,7,63,,4,3 3 7 6,8 9,8 6,7 33,4 4 9, 6,8 9, 36,,98,8,74,6,,86,74,63,,4 the heat exchanger [kpa] 33 6 6 7 3 7 9 S-3S S-3S S-3S /3 9/7 8/6 - - 9,4 7,3 4,69 - - - -,44 38,8 34 9,4 4,9,7 34, 9,8,3,9 6,8 9,9 6,8 3,6 3,3 36,8,,3,,9,74 8,7,6 7, 34, 4,8,,7,,9,,9 7 -,3 4,, 7,8 4,,,4,3, 6 4 9 4 S-3S S-3S S3-3S 7/ /3 9/7 - - - - - - 3,,6, 6,9,8,4 7,8 8,7 4,7 68,9 6,3, 44,3 36,8 6, 9,7 6,4 3,8 -,4,3,4 4,7 39,8 44,3 48,7,9,3,,9,74,6,93,74,,38, 3,4,66,9,9,6 3 4 3 3 6 6 8 9 6 3 S3-3S S3-3S S3-3S 8/6 7/ /3 - - - - 6, 3 4 37,4 3, 4 4,8 37,9 3, 3,3 33,3 37,8 4, 46,3, 6,8 3,3 39, 43,4,7,33,98,64,3,36,66,33 43 33 4 7 3 6 3, - 38,9 3, 3,6 6,3 9,3,8,9 9,3,,69,3,,7,4 7 8 4 - S4-3S S4-3S S4-3S 9/7 8/6 7/ - 78,6 6 3,46 38-68,7 3,9 3,3 9 9,3 37,,6 S4-3S /3,3 43, 6,9 - - - - 4,7 69,9 6, 4, 33,8 6,,7 4,7 34,,8 48,3 6,7 3,3 37,7 4,9,8, 7 3,3 37,,84 3,7,64,4,8,48,67,6,87,49, 3 3 7 8 4 8 6 - - 43,4 3,,8 7,6 9,,4 6,3, 6,4,88,3,,76,4 9 3

3. ASSEMBLY - Before plugging the electric supply check the leak tightness. Air water heaters Reventon Group S-3S series can be assembled on the wall or ceiling via rotating mounting brackets. The drawings below show the ways of assembly. In the bigger accommodation, it is recommended to assemble more than one device. Follow the parameters which are provided on the drawings. - The device does not consist of the anti-frost protection. The temperature in the room should not go below C. In such case please empty the device out of water. - It is recommended to check the electric installation before the first start. - It is recommended to use the external current deferential protection. - After the turn off, the elements of device may be warm. - After operating time of the device, please utilize it concerning the local norms and regulations. It is recommended to clean the device periodically: źheating coil blow through by compressed air, źfan casing and blades clean form the dirt. - If the device is not used for a longer time disconnect the voltage supply. - The device is transported with the closed air stators. It is essential to open them in 3 % before first start. Not keeping to the following recommendation may cause the damages of the fan. Reventon Group devices can be assembled on the wall or ceiling via rotating mounting bracket. It is possible to assemble the device in parallel on the angle 6. Please follow the parameters as shown below. - Opening the air stators must be made by two hands in parallel. Not keeping to the following recommendation may cause the damages of the air stators. REGULACJA STOPNIA NACHYLENIA PRZY UŻYCIU UCHWYTÓW MONTAŻOWYCH 4. INSTALLATION INSTRUCTIONS The installation should be made by the qualified staff, who possess the needed rights to install electrical devices, as instructed in the following documentation. The duct size for air water heaters Reventon Group S-3S series should be chosen by the designer. While plugging the device to the water installation do remember to hold its stub pipes by pipes spanner, not keeping to the recommendation may cause the damages of the heating coil.. PRECAUTIONS & WARNINGS All works concerning electrical installation should be made by the qualified staff, who possess the qualifications due to the domestic and local norms. These recommendations include service and disassembly as well. Not following to the recommendations may cause electrocution, device damages or its incorrect work. Outlet - Before service or exchange of the device it is obligatory to cut off the current supply. - Do not cover the inlet and outlet of the device. - Do not use the device in room with high moisture or close to the water basin. - Do not install, service the device with wet hands or barefoot. - Do not use the device in room with flammable fumes, gas and high concentration of dust. - The device should be kept out of reach of children and animals. - During the assembly use the filter on the hydraulic supply. - The device should be secured against pressure increase in the water installation. Inlet

Fan speed controller HC A 6. CONTROLS designed to change the single-phase fan's speed voltage controlled in industrial supply and heating systems To make easier the usage of the Reventon Group devices we also offer the additional controls: Power supply voltage: 3V /6Hz Allowable current output: A Maximum ambient temperature 4 C Maximum temperature controller 7 C, limited motor protection. Dimensions: 4 mm x 9 mm x mm Weight: 8, kg Degree of protection: IP 4 3-stage speed controllers with thermostat Controller is used to regulate devices equipped with 3-stage fans. It has 3-stage speed control and thermostat built in. In addition, the unit controls the operation of the actuators installed on the control valve. Works in both heating and cooling modes. Voltage: 3V /6Hz Rated current: 3A Temperature range: C~3 C operating modes: continuous and thermostatic Control accuracy: < C Working environment parameters: -... + C Dimensions: x8x4 mm Weight:,kg Degree of casing's protection: IP3 Fan speed controller HC 4A designed to change the single-phase fan's speed voltage controlled in industrial supply and heating systems Power supply voltage: 3V /6Hz Allowable current output: 4 A Maximum ambient temperature 4 C Maximum temperature controller 7 C, limited motor protection. Dimensions: 4mm x 9 mm x mm Weight:,kg Degree of protection: IP 4 Fan speed controller HC,A designed to change the single-phase fan's speed voltage controlled in industrial supply and heating systems Power supply voltage: 3V /6Hz Allowable current output:, A Dimensions: 6mm x 76mm x 6mm Degree of protection: IP 4 Two-way valve with actuator ¾ Power: 3V /6 Hz Total current: <,A Input: <, (3,3VA) Auxiliary microswitch: A Maximum operating temperature: 6ºC Degree of protection: IP4 Closing time: -6 min Adjustment stroke: 3,6 mm Fan speed controller HC 3A designed to change the single-phase fan's speed voltage controlled in industrial supply and heating systems Module relay RM-6A Relay module RM-6A opens and closes the circuit to affect the work Power supply voltage: 3V /6Hz Allowable current output: 3 A Dimensions: 6mm x 76mm x 6mm Obudowa w stopniu ochrony : IP 4 of other devices. It can be used to connect a receiver with higher power than the relay in the controller allows. Maximum rated current is 6A. Power supply: 3 V AC Maximum rated current: 6 A Input: NO/COM Input SL Connection of a regulator with the voltage relay 3 V Output signal: relay NO/COM/NC Dimension: 47 x 47 x mm Fan speed controller HC A designed to change the single-phase fan's speed voltage controlled in industrial supply and heating systems Power supply voltage: 3V /6Hz Allowable current output: A Maximum ambient temperature 4 C Maximum temperature controller 7 C, limited motor protection. Dimensions: mm x 7 mm x mm Weight: 3,8 kg Degree of protection: IP 4 Programmable room thermostat HC Number of temperature levels: Hysteresis:, /ºC Power: baterie AA Switching: 3 VAC/Hz (3) A Operating temperature range: -4ºC Temperature control range: -3ºC Accuracy of temperature:,ºc Number of programs: 9 Fan speed controller HC 7A designed to change the single-phase fan's speed voltage controlled in industrial supply and heating systems Manual thermostat HC Power supply voltage: 3V /6Hz Allowable current output: 7 A Maximum ambient temperature 4 C Maximum temperature controller 7 C, limited motor protection. Dimensions: 4 mm x 9 mm x mm Weight: 6,4 kg Degree of protection: IP 4 Operating temperature: -4ºC Temperature control range: -3ºC Accuracy of temperature: ºC Number of programs: Rated current: 3A COOPERATION WITH EQUIPMENT HC A HC 7 A HC A HC 4 A RM-6A FSHC-67 FS7HC-68 FSHC-69 FS4HC-6 RM6A-786 7 7 3 4 7 4 7 7 4 7 3 6 8 6 9 Model HC3S HC, A Code RTHC3S-779 FSHC- REVENTON S-3S 7 7 REVENTON S-3S REVENTON S3-3S REVENTON S4-3S 3 HC 3 A FS3HX-

7. CONNECTION SCHEMES LEGEND:. Power. Main switch, overcurrent circuit breaker * 3. Air water heater Reventon S series 4. 3-stage speed controllers with thermostat A-work in continuous mode B-operation in thermostatic mode. Two-way valve with actuator HC ¾ " 6. Fan speed controller HC 7. Manual thermostat HC 8. Digital programmable thermostat HC 9. Relay module RM-6A * main switch and safety fuses are not included in the set

8. TERMS OF WARRANTY I.Reventon Group Sp. z o.o. [Ltd.] 3B Montazowa Street, 43-3 Bielsko-Biała, Poland, is the producer of the Reventon Group brand. The warranty concerns the following devices and it is valid for (two) years: - air water heater Reventon S-3S - air water heater Reventon S-3S - air water heater Reventon S3-3S - air water heater Reventon S3-3S 7kW 3V 9kW 3V kw 3V 9kW 3V II. Warranty is valid in the European Union. III.The terms of warranty are valid from purchasing the device (the date issuing a document confirming the purchase of the device) but not further than 3 (thirty) months from leaving the producer s warehouse. IV.The defects revealed during the warranty period will be removed free of charge in 4 working days. The service will be done by the installation company due to the terms included in warranty card. The elements will be supplied by the Reventon Group Sp. z o.o. during the warranty period. V.Warranty does not cover the parts of the device subject to normal maintenance and the cases as below: a) Mechanical defects, damages from the impact of the improper transportation or damages through improper storage. b) Defects through: - improper usage and service; - using the device in the improper conditions (too high humidity, too high or too low temperature, impact of the surrounding, sun etc.); -modified equipment that has been modified or repaired without written agreement of the producer; - connecting additional equipment, which is not recommended by the producer or inconsistent with the technical documentation; - improper power supply. c) Elements which wear and tear such as discolor or using. VI.All changes in record in the warranty terms or any constructive modifications, independent service outside the Reventon Group Sp. z o.o. service or use, uncaring, makes the warranty not valid. VII.To obtain the service it is needed to send to the producer warranty card with the signature, document confirming the purchase, (copy of the invoice) and correctly filled the warranty form. VIII. Not following to any of warranty regulations makes the warranty not valid. IX.All correspondence, returns, complains should be send to the following address: Reventon Group Sp. z o.o. 3B Montazowa Street, 43-3 Bielsko-Biała, Poland or e-mail: serwis@reventongroup.eu The producer reserves the rights to make changes to the technical documentation without previous notice.

Warranty card : : : : : Reventon Group [Ltd.] 3B Montazowa Street, 43-3 Bielsko-Biała, Poland

Reventon Group Sp. z o.o., ul.montażowa 3B, 43-3 Bielsko-Biała, Polska, www.reventongroup.eu