A Specifications. Ver.1.1. Page: EKMC Product Name. Model Number. 3.Dimensions. Approved by. Checked by.

Similar documents
C Specifications. Ver.1.1. Page: EKMB Product Name. Model Number. 3.Dimensions. Approved by. Checked by. ,2017 Jul.

E Specifications. Ver.1.2. Page: EKMC Product Name. Model Number. 3.Dimensions. Approved by. Checked by.

G Specifications. Ver.1.1. Page: EKMC K. 1.Product Name. Model Number. 3.Dimensions. Approved by. Checked by.

G Specifications. Ver.1.1. Page: EKMC K. 1.Product Name. Model Number. 3.Dimensions. Approved by. Checked by. ,2018 Mar.

C 46 K a d. Specifications EKMC K. Ver.1.1. Page: EKMC K. 1.Product Name. 2.Model Number. 3.Dimensions. Approved by.

G Specifications. Ver.1.1. Page: EKMC K. 1.Product Name. Model Number. 3.Dimensions. Approved by. Checked by. ,2018 Mar.

PIR MOTION SENSOR. PIR Motion Sensor (EKMB, EKMC, AMN2, 3)

Simplified circuitry with fully integrated sensor design. Low curvature lens for product designs. Robust design prevents false detection

SP/WL/VZ SERIES. PaPIRs MOTION SENSOR

PIR MOTION SENSORS

Data Sheet Sensor: IRA-S210ST01 Lens: IML-0685 / IML Sensor : IRA-S210ST01 Lens : IML-0685/0688. Pyro Electric Infrared Sensor Fresnel Lens

Selectable 2sec., 7sec., 15sec. (selectable by holding time setting switch)

Ionizer (Static Remover) STABLO-EX Instruction Manual

Handling or using the product improperly and in disregard of the instructions with this mark might result in serious bodily injury or death.

Buzzer Unit. TAN-5000 Series. Operating Manual

Applications PL- N Series Lens Type Sensor Type Serial Number

APPROVED BY CHECKED BY DRAWN BY

Read this Safety Guide first.

Sensor : IRA-S210ST01 Lens : IML-0685/0688 Pyro Electric Infrared Sensor Fresnel Lens Features Applications Excellent S/N Intrusion Detectors

ZMOTION Pyroelectric Sensors

Pyroelectric Infrared Sensors

FT10Aseries. Self-check feature provided. Fiber type / CMD. Within detecting distance 40 m

ML520G55 FEATURES. Package: φ5.6mm TO-CAN PKG APPLICATION. Reverse voltage

ML501P73 TYPE NAME. FEATURES High Output Power: 1.0W (Pulse) 0.5W (CW) High Efficiency: 1.0mW/mA (typ.) Visible Light: 638nm (typ.) 5.

Metal, ceramic, plastic package products

Pyroelectric Infrared Sensors

ML60171C FEATURES. φ5.6mm TO-CAN PKG (with monitor PD) APPLICATION Motion sensor Printing. Reverse voltage (PD)

HEA-900 EDENPURE INDOOR/OUTDOOR ALL SEASON INFRARED HEATER

ML562G84 APPLICATION. Display system. Symbol Parameter Conditions Ratings Unit. Pulse (Duty 40%)

AUR300C, AUR350C. Advanced Ultraviolet Burner Controller

CORONA BURNER CONTROLLER INSTRUCTION MANUAL RCF15 EXCLUSIVE FOR FLAME ROD. Corona Corporation

Description. Optex Incorporated

DAIKIN ROOM AIR CONDITIONER. Operation Manual

Pyroelectric Infrared Radial Sensor

Pressure Switches Precautions 1 Be sure to read this before handling.

SMART Dust Sensor. Amphenol Advanced Sensors SM-PWM-01C. Application Note. Features

CA870 INFRARED THERMOMETER E N G L I S H. User Manual. Auto OFF

SPECIFICATION of PYROELECTRIC PASSIVE INFRARED SENSOR

E3M-V. Mark Sensor. Applications

MANUAL. OEM (Unit) OZONE GENERATOR (100VA, 200VA and 300VA) INDEX

Owner s Manual. Middle Static Pressure Duct Type MEU-18MPH2 MEU-24MPH2 MEU-36MPL2 MEU-48MPL2 MIDDLE STATIC PRESSURE DUCT TYPE AIR CONDITIONER

PHOTOELECTRIC BEAM SENSOR PR-11BE : OUTDOOR 3.3 to 36ft. (1 to 11m) : INDOOR 3.3 to 49ft. (1 to 15m)

PIR Motion Sensor. Special Designs from Panasonic that Provide High Sensitivity and Reliability

DUCTED AIR CONDITIONER. Owner s Manual. KD Series KD24. Kaden Owner s Manual 1

Color Mark Sensor. Sensing gdsa distance Spot diameter e. Possible to switch between vertical or horizontal connection using the M12 rotary connector.

250mm dia straight pipe length SP4 SP3. Air volume

Application note. LCD Module. Precautions for LCM handling. LCM handling V 1.1

DUAL ZONE OUTDOOR PIR MS-12TE & MS-12FE

Smart Transmitter/ Gas Detector Head

Advanced Ultraviolet Burner Controller

Warning Caution. Safety Precautions (Be sure to read these precautions before using our products.)

NON-DUCTED TYPE SMOKELESS BBQ ROASTER MODEL NJG-C

D-TECT 3 IP. GJD260 IP Motion Detector

16 mm. Ionizer Nozzle type. Ion balance ±10 v. Slim design: Thickness dimension 16 mm RoHS compliant. Series IZN10

D-TECT 2 IP. GJD230 IP Motion Detector

Chapter 7. Troubleshooting

Technical data sheet TDS0060

PRODUCT SPECIFICATION. 0.5mm Fine Stacking. Hermaphroditic Type BTB Connector

GENERAL INSTRUCTIONS FOR THE TM BI0MATMX

HOA1888 Series. Infrared Assemblies Wide Gap Transmissive Sensor. MICRO SWITCH Sensing and Control

ELIMINOSTAT DC-ESR-CL-S2

ULTRA LOW TEMPERATURE FREEZER. User Manual

AUR300C. Advanced Ultraviolet Burner Controller

Technical data sheet TDS0034

2015 Amphenol Advanced Sensors. Jinton Industrial Park, Wujin, Changzhou, Jiangsu, China. Web:

CAUTIONS ON INSTALLATION

DAIKIN ROOM AIR CONDITIONER. Operation Manual. English. Deutsch. Français. Nederlands. Español. Italiano. Ελληνικά. Portugues. Русский.

2. Contact form 6: 1c (SPDT) Load voltage (peak value) quantity Fully Sealed 1c (SPDT) 5 VDC 5 VDC 60 V 400 ma 130 ma G3VM-66M 50 pcs/tube

ISHIDA CO., LTD. Do not carry out installation, operation, service or maintenance until thoroughly understanding the contents of this manual.

CABINET INFRARED HEATER

Owner s Manual Super-Slim Four-Way Cassette

Victoreen Primalert 35 Area Radiation Monitor

PDU Power Distribution Unit for IP-NINJAR. User s Guide Ver

Utopian Split A/C. Thank you for purchasing this quality Split A/C system!

WHYNTER Eco Pure Air Purifier

IEC UC3 compliant (short current 3,000 A) 1 Form A 120A power latching relays

HYGROMER - MP 400 A Meteorology probe

RK/ RK Oxygen Detector Operator s Manual

USER MANUAL. FairWind FWPC6L Pressure Cooker. Contact Us:

INSTALLATION MANUAL. Decoration Panel Provided with Filter Auto Cleaning Function Self Cleaning decoration panel BYCQ140D7GW1 BYCQ140D7GFW1

Furnace Gas Monitor SD Operating Manual (PT2-163)

30-pint Dehumidifier User Guide

User s Manual. Electronic Personal Dosimeter (For Gamma(X)-ray) NRF30. Fuji Electric Co., Ltd. TN514629i 1/31

No.THD51E To prevent accidents arising from the use of this product, please ensure the operator using it receives this manual.

Portable Refrigerator

MANUAL. Instructions for installation use & general maintenance of your HORIZONTAL FREEZER HFF, FLORENCIA and MILAN Product Lines MAN-017-R

MODEL: SP12C7. (Portable 4 gas detector) Operating Manual

FAR INFRARED RAYS HEATER

Small diffuse reflective and convergent reflective type BYD50-DDT BYD50-DDT-U 1 BYD100-DDT BYD3M-TDT BYD3M-TDT-P

5800-OD Wireless Outdoor Motion Sensor Installation Instructions

EVAPORATIVE AIR COOLER SERVICE MANUAL

10 to 30 VDC Diffuse 40 mm ±10 mm NPN and PNP, switch-selectable

NIDS Dust sensor ED-N-DS-1408

TILT SENSOR SWITCH. Item No. RBS Description Ball-Contact Version 13 Page 1 of 7 Publish Date May 29, 2018

Flame Simulator User Manual. Publication Rev. A

Installation Guide. Home Network System Motion Sensor KX-HNS102HM. Model No.

Monsoon RS400. Operating Instructions Mode d emploi Bedienungsanleitung Manual de Instrucciones Istruzioni per il funzionamento Gebruiksaanwijzing

TILT SENSOR SWITCH. Item No. RBS Description Ball-Contact Version 15 Page 1 of 7 Publish Date May 13, 2018

Detailed operating instructions

CR-1730R User s Manual

Transcription:

A745 Specifications 1 1. VZ series Horizontally wide detection type (170μA / Digital output ) 2.Model Number Lens Color White Black Pearl White Model Number 1 2 3 Marking 3.Dimensions Top VIEW Side VIEW Bottom VIEW A 7 45 a) b) c) a) The Marking which was shown by a list shown below Marking A B C D E Model Number EKMB130511 K EKMB110511 EKMB120511 EKMB260511 b) Last-digit of the year (Ex:2017=7,2018=8, ) c) Lot No. 1 st week of Jan. will be 01, and further No. of 02,03, will continue up to 53. General Tolerance ±0.5mm (±0.020inch) Issued on Jul. Issued 12 th on,2017 Jul. 12 th,2017 Approved by Checked by Designed by

2 4.Characteristics 4-1 Performance ( Area A) Conditions for measuring: Ambient temperature=25 (77 F) Operating voltage=5vdc (Note1) Range Temperature difference 4 (7.2 F) Max 5m Conditions concerning the target 1.Movement speed: 1.0m/s 2.Target concept is human body (Object size:around 700 250mm) Note1:Depending on the temperature difference between the target and the surroundings, detection range will change. Area Horizontal 122 (±61 ) Vertical 35 zones 88 +10-25 Notes Refer to the section 4-6. 4-2 Performance ( Area B) Conditions for measuring: Ambient temperature=25 (77 F) Operating voltage=5vdc (Note1) Range Temperature difference 8 (14.4 F) Max 5m Conditions concerning the target 1.Movement speed: 1.0m/s 2.Target concept is human body (Object size:around 700 250mm) Note1:Depending on the temperature difference between the target and the surroundings, detection range will change. Area Horizontal 150 (±75 ) Vertical 20 (±10 ) zones 16 Notes Refer to the section 4-6. (Ditection Area A is not included.)

3 4-3 Maximum Rated s Unit Power Supply Voltage -0.3~7 VDC Usable Ambient Temperature Storage Temperature -20~+60 (-4~+140 F) Do not use in a freezing or condensation environment -20~+70 (-4~+158 F) 4-4 Electrical Characteristics Conditions for Measuring: Ambient temperature=25 (77 F) Symbol Min Avg. Max Unit Special mention Operating Voltage Vdd 3.0-6.0 VDC - Electrical Current Consumption Iw - 0.17 0.3 ma Iout=0 Output Current Iout - - 100 μa Vout Vdd-0.5 Output Voltage Vout Vdd-0.5 - - VDC - Circuit Stability Time (when voltage is applied) Twu - - 30 s - 4-5 Timing Chart Power Supply ON OFF Detecting Target Present Absent Output Voltage ON OFF Twu Durations Twu:Circuit Stability Time=About 30s. (max.) During this stage, the output s status is undefined (ON/OFF) and detection is therefore not guaranteed.

4 4-6 Area Side View Area A Top View Area B Area B 4-7 Wiring Diagram Sensor Vdd + GND OUT Load + Iout:Max.100μA

5 5. Safety Precautions Head the following precautions to prevent injury or accidents. 1) Do not use these sensors under any circumstance in which the range of their ratings, environment conditions or other specifications are exceeded. Using the sensors in any way which causes their specifications to be exceeded may generate abnormally high levels of heat, emit smoke, etc., resulting in damage to the circuitry and possibly causing an accident. 2) Our company is committed to making products of the highest quality and reliability. Nevertheless, all electrical components are subject to natural deterioration, and durability of a product will depend on the operating environment and conditions of use. Continued use after such deterioration could lead to overheating, smoke or fire. Always use the product in conjunction with proper fire-prevention, safety and maintenance measures to avoid accidents, reduction in product life expectancy or break-down. 3) Before connecting, check the pin layout by referring to the connector wiring diagram, specifications diagram, etc., to verify that the connector is connected properly. Mistakes made in connection may cause unforeseen problems in operation, generate abnormally high levels of heat, emit smoke, etc., resulting in damage to the circuitry. 4) Do not use any motion sensor which has been disassembled or remodeled. 5) Failure modes of sensors include short-circuiting, open-circuiting and temperature rises. If this sensor is to be used in equipment where safety is a prime consideration, examine the possible effects of these failures on the equipment concerned, and ensure safety by providing protection circuits or protection devices. Example : Safety equipments and devices Traffic signals Burglar and disaster prevention

6 6.Operating Precautions 6-1 Basic Principles PaPIRs is a pyroelectric infrared sensor that detects variations in infrared rays. However, it may not detect in the following cases: lack of movement, no temperature change in the heat source. Besides, it could also detect the presence of heat sources other than a human body. Efficiency and reliability of the system may vary depending on actual operating conditions: 1) Detecting heat sources other than the human body, such as: a) small animals entering the detection area b) When a heat source for example sun light, incandescent lamp, car headlights etc, or strong light beam hit the sensor regardless inside or outside the detection area. c) Sudden temperature change inside or around the detection area caused by hot or cold wind from HVAC, or vapor from the humidifier, etc. 2) Difficulty in sensing the heat source a) Glass, acrylic or similar materials standing between the target and the sensor may not allow a correct transmission of infrared rays, b) Non-movement or quick movements of the heat source inside the detection area. (Please refer to 4-1 for details about movement speed.) 3) Expansion of the detection area In case of considerable difference in the ambient temperature and the human body temperature, detection area may be wider apart from the configured detection area. 4) Malfunction / error Unnecessary detection signal might be outputted, on rare occasions, come from sudden outbreak output due to the nature of pyro-electric element. When the application does not accept such condition strictly, please implement the countermeasure by introducing pulse count circuit etc. 6-2 Optimal Operating Environment Conditions 1) Temperature : Please refer to the maximum rated values of 4-2. 2) Humidity Degree :15~85% Rh (Avoid condensation or freezing of this product) 3) Pressure : 86~106kPa 4) Overheating, oscillations, shocks can cause the sensor to malfunction. 5) This sensor is not waterproof or dustproof. Avoid use in environments subject to excessive moisture, condensation, frost, containing salt air or dust. 6) Avoid use in environments with corrosive gases.

7 6-3 Handling Cautions 1) Do not solder with a soldering iron above 350 (662 F), or for more than 3 seconds. This sensor should be hand soldered. 2) To maintain stability of the product, always mount on a printed circuit board. 3) Do not use liquids to wash the sensor. If washing fluid gets through the lens, it can reduce performance. 4) Do not use a sensor after it fell on the ground. 5) The sensor may be damaged by ±200 volts of static electricity. Avoid direct hand contact with the pins and be very careful when operating the product. 6) When wiring the product, always use shielded cables and minimize the wiring length to prevent noise disturbances. 7) The inner circuit board could be destroyed by a voltage surge. Use of surge absorption elements is highly recommended. Surge resistance : below the power supply voltage value indicated in the maximum rated values section. 8) Please use a stabilized power supply. Power supply noise can cause operating errors. Noise resistance : ±20V or less (Square waves with a width of 50ns or 1μs) To reduce the effect of power supply noise, install a capacitor on the sensor s power supply pin. 9) Operating errors can be caused by noise from static electricity, lightning, cell phone, amateur radio, broadcasting offices etc 10) performance can be reduced by dirt on the lens, please be careful. 11) The lens is made of soft materials (Polyethylene). Please avoid adding weight or impacts that might change its shape, causing operating errors or reduced performance. 12) Operating temperatures and humidity level are suggested to prolong usage. However, they do not guarantee durability or environmental resistance. Generally, high temperatures or high humidity levels will accelerate the deterioration of electrical components. Please consider both the planned usage and environment to determine the expected reliability and length of life of the product. 13) Do not attempt to clean this product with any detergent or solvent, such as benzene or alcohol, as these can cause shape or color alterations. 14) Avoid storage in high, low temperature or liquid environments. As well, avoid storage in environments containing corrosive gas, dust, salty air etc. It could cause performance deterioration and the sensor s main part or the metallic connectors could be damaged. 15) Storage conditions Temperature: +5 ~ +40 (+41 ~ +104 F) Humidity: 30 ~ 75% Please use within 1 year after products delivery.

8 7.When Designing Your Product 7-1 Using Area A and B range Note3 Recommended panel mounting hole dimensions 7-2 Using Area A only range Note2 Note3 Recommended panel mounting hole dimensions Note1 : In order to ensure proper detection,install it with the lens exposed at least 6.2mm.(0.244inch) Note2 : In order to ensure proper detection,install it with the lens exposed at least 0.7mm.(0.028inch) Note3 : As for panel mounting hole,tapering or making a large size hole should be done.

9 7-3 Recommended PCB Pattern Diagram 8.Special Notice As improvements are continually being made, the specifications or design of this product are subject to change without notice. Please strictly follow the Safety Precautions and Operating Precautions on the specifications sheet. Normal functioning cannot be expected if used in environments or conditions other than those specified above. We are deeply committed to providing the highest quality control for this product. Nevertheless: 1) For issues not addressed above, we invite you to share your suggestions, or details about your company s usage conditions, installation, specifications, needs of end users, and applications for this sensor. 2) To reduce the risk of harm caused by product failure to human life or assets, this product should always be used in conjunction with other safety measures, such as protective circuitry, double layered circuit boards, etc., and used within the guaranteed performance, efficiency or special characteristics values stated in the specification sheet. 3) This product is warranted for a period of one year, from date of delivery, applicable only if the product is used in accordance with the precautions mentioned above and the specifications sheet. We will replace or repair at the delivery location any malfunctioning or defective part or entire product if such defect or malfunction is caused by us. However, the above warranty shall be void in the following circumstances: a) Damage caused to something else than the product itself. b) Damage or loss resulting during transportation, storage or handling after the date of supply. c) Phenomenon unforeseeable in the state of the technology as of the supply date. d) Damage caused by natural or unnatural events such as fire, earthquake, flood, or conflicts beyond our control.