APPENDIX X. Contents:

Similar documents
PARISH OF ASCENSION OFFICE OF PLANNING AND DEVELOPMENT PLANNING DEPARTMENT

ORDINANCE NO

Louisville Metro Ordinance (Chapter 94: Fire Prevention) FIRE HYDRANTS, WATER MAINS AND WATER SUPPLY.

Chapter 100 FIRE PREVENTION

FIRE PREVENTION OFFICE Placer Hills Fire Protection District NEW PROJECT GUIDELINES

Chapter 8 FIRE PREVENTION, PROTECTION AND AMBULANCE FEES * ARTICLE I. IN GENERAL

Mobile Fire Rescue Department Bureau of Fire Prevention

MEMORANDUM. FIRST READING OF ORDINANCE 15-43, update of Chapter 38, (Fire Protection and Prevention) of the City of Dunedin Code of Ordinances

Site Plans. Fire Code Requirements

MCKINNEY FIRE DEPARTMENT FIRE MARSHAL S OFFICE FIRE LANES

FIRE SERVICE FEATURES

CITY OF CHESAPEAKE PUBLIC FACILITIES MANUAL CHAPTER XIII FIRE PROTECTION

TETON COUNTY FIRE PROTECTION RESOLUTION FOR NEW SUBDIVISIONS 2008 Edition. Chapter I General Provisions

FIRE PREVENTION CODE

4/13/2015. Everything a firefighter wants to tell a design professional or building code official, in one hour.

LANDSCAPE ORDINANCE PASADENA PLANNING DEPARTMENT (713) FAX (713)

FIRE PLAN CHECK CORRECTION List for Commercial Occupancies

TAMARAC FIRE RESCUE DEPARTMENT FIRE PREVENTION BUREAU 6000 North Hiatus Road Tamarac, Florida Telephone: (954) , Fax: (954)

Glenwood Springs Fire Protection District Amendments to the 2009 International Fire Code

ORDINANCE NO. 787 (AS AMENDED THROUGH 787.7) AN ORDINANCE OF THE COUNTY OF RIVERSIDE ADOPTING THE 2013 CALIFORNIA FIRE CODE AS AMENDED

DRIVEWAY REGULATIONS

PINETOP FIRE DEPARTMENT TIMBER MESA FIRE AND MEDICAL DISTRICT

* - Additional codes referenced in these publications shall be considered as adopted by the Town of Bedford and enforceable.

ICC CODE CORNER 2015 International Fire Code

A Comprehensive Community Risk Reduction Initiative A COMPREHENSIVE COMMUNITY RISK REDUCTION INITIATIVE

This guide is intended to provide assistance in the application of the fire code in all areas served by Tualatin Valley Fire & Rescue.

Council of the City of York, PA Session 2008 Bill No. Ordinance No. INTRODUCED BY: Genevieve Ray DATE: November 18, 2008

Fire & Life Safety Requirements For Fire Department Access and Water Supplies

ORDINANCE NO , Series of , AND OF THE PARKER MUNICIPAL CODE CONCERNING THE PARKER FIRE PROTECTION CODE

SOMERSWORTH CODE FIRE PREVENTION AND LIFE SAFETY CHAPTER 21

CHAPTER 92: FIRE PREVENTION; FIREWORKS

Town of Bridgton FIRE PROTECTION AND LIFE SAFETY ORDINANCE

FIRE PREVENTION CODE. conditions hazardous to life and property from fire, hazardous materials, or explosion.

FIRE PREVENTION AND PROTECTION*

Public Notice of Amendment to New Shoreham General Ordinances Chapter 5 Fire Prevention and Protection New Article IV Fire Alarm Ordinance

Chapter 2: Identification, water and access

CITY OF PALM BEACH GARDENS ORDINANCE NO. 12, 2002

ORDINANCE NO

International Fire Code 2006 Requirements for Construction Plan Reviews of Commercial and Multi-Family Structures

Mt. Crested Butte Code

VACAVILLE FIRE PROTECTION DISTRICT 420 Vine Street Vacaville, California (707)

Fire Department Access and Water Supply

BE IT ORDAINED BY THE BOARD OF DIRECTORS OF THE FENTON FIRE PROTECTION DISTRICT OF ST. LOUIS COUNTY, MISSOURI AS FOLLOWS:

ARTICLE IX SPECIAL PERMIT USES

CHAPTER FIRE CODE

To encourage commercial development which is consistent with the long range, comprehensive, general plan for Knoxville and Knox County.

Title 14 Fire Code. (Ord. 2426, Amended, 06/22/2009; Ord. 2407, Amended, 08/11/2008; Ord. 2266, Add, 02/28/2005)

OXNARD FIRE DEPARTMENT 360 West Second Street Oxnard, CA (805) Fax (805)

ORDINANCE NO WHEREAS, the City of Hammond Water Department owns and operates


EXHIBIT A STEAMBOAT SPRINGS FIRE PREVENTION SERVICES ADMINISTRATIVE POLICY & PROCEDURE MANUAL

CONTRACT FOR USE OF FIRE PROTECTION SYSTEM

DRIVEWAY LOCATION APPROVAL RULES AND REGULATIONS

CHAPTER 26-ORDINANCES FIRE PREVENTION REGULATIONS

Drexel Heights Fire District 2012 International Fire Code Amendments

District of Sicamous. Fire Department Bylaw No. 126, Effective Date February 26, 1996

New Construction Fire Inspection Process

Article 14. LIGHTING REGULATIONS

A BILL FOR AN ORDINANCE TO AMEND CHAPTER 9, KAUAI COUNTY CODE 1987, RELATING TO STREET REQUIRE:MENTS FOR SUBDIVISIONS

CHAPTER 6 FIRE SAFETY STANDARDS. Adopted: September 22, Revised: August 7, April 1, May 15, June 1, 2003

Fire & Life Safety Supplemental Rules & Regulations for New Construction & Significant Remodels

WHEREAS, the City Commission of the City of Cocoa Beach, Florida finds that this ordinance promotes the public health, safety and welfare.

ORDINANCE NUMBER

FIRE SERVICE FEATURES


EXHIBIT A STEAMBOAT SPRINGS FIRE PREVENTION SERVICES ADMINISTRATIVE POLICY & PROCEDURE MANUAL

Driveway Regulations TOWN OF FREMONT ROCKINGHAM COUNTY NEW HAMPSHIRE

City of Chilliwack. Bylaw No A bylaw to regulate fire prevention and the protection of life and property

S000 SITE REVIEW APPR NO. FIRE CODE COMPLIANCE ITEM

ARTICLE V PLANNED UNIT DEVELOPMENT DISTRICT

MOBILE FOOD VENDING Food Trucks & Trailers

ORDINANCE AN ORDINANCE TO ADD A NEW SECTION 4.N. IN THE ZONING CODE FOR THE TOWN OF MIDDLETOWN, RELATING TO MIXED-USE DEVELOPMENT

FIRE APPARATUS ACCESS AND WATER SUPPLY GUIDELINE

2009 INTERNATIONAL FIRE CODE AMENDMENTS

FIRE SAFETY CHAPTER 18A FIRE SAFETY

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU STANDARD

TABLE OF CONTENTS ADOPTED FIRE CODES... 3 AFPD SERVICE AREA... 3 SITE AND DEVELOPMENT SUBMITTAL REQUIREMENTS... 4 PLAN REVIEW FEES...

CHAPTER 23 FIRE SAFETY MEASURES

ORDINANCE NO WHEREAS, the WSBCC has recently adopted new editions of several of such International codes; and

DISTRICT OF PORT HARDY BYLAW A BYLAW TO ESTABLISH AND REGULATE THE DISTRICT OF PORT HARDY FIRE DEPARTMENT

ORDINANCE NO, 5907 AN ORDINANCE AMENDING ALBANY MUNICIPAL CODE CHAPTER , UNIFORM FIRE CODE

Module 3. Water-Based Suppression Systems (WBSS) Part II: Highlights of Code Requirements

City of Chilliwack. Bylaw No A bylaw to regulate fire prevention and the protection of life and property

Fire Prevention Bureau INFORMATION PACKAGE

The Town Board of the Town of Vienna, County of Dane, State of Wisconsin, does ordain and adopt as follows.

The purpose of the requirements in this Article is to provide for landscaping and screening of parking and other outdoor areas that will:

S 2758 S T A T E O F R H O D E I S L A N D

Fire Sprinkler System Design and Installation Requirements

CHAPTER 10. FIRE PROTECTION AND PREVENTION ARTICLE I. IN GENERAL

SPRINKLER ORDINANCE Town of Yarmouth, Maine Recodified: 1/15/98 Amended: 4/19/01 Amended: 6/18/15

ARTICLE 17 SITE PLAN REVIEW

First Published in the Wichita Eagle on DELINEATED 10/02/2010 ORDINANCE NO.

City of Los Angeles January FIRE PROTECTION

SECTION RESIDENTIAL LANDSCAPING, STREETSCAPING, AND AMENITY STANDARDS

FIRE SAFETY PLAN. BUILDING NAME: Pathobiology / AHL BUILDING NUMBER: 089. DATE: 15-August-10 FPO #2

CHESAPEAKE LANDSCAPE ORDINANCE

GUIDELINES FOR EMERGENCY PLANNING AND PREPAREDNESS. High-Hazard

SANTA CLARA COUNTY Winchester Blvd., Los Gatos, CA (408) (408) (fax)

SECRETARY S CERTIFICATE

Water Purveyor s Guide to 2006 Fire Sprinklers in Single Family Dwellings

Transcription:

PARISH OF ASCENSION OFFICE OF PLANNING AND DEVELOPMENT APPENDIX X FIRE HYDRANT CODE Contents: 17-1001. 17-1002. 17-1003. 17-1004. 17-1005. 17-1006. 17-1007. 17-1008. 17-1009. Purpose... 3 Fire Hydrants Regulations... 3 Fire Protection and Prevention: General Provisions... 3 Installation:... 3 Marking of fire hydrants:... 4 Placement of fire hydrants:... 5 Obstruction of fire hydrants:... 5 Fire hydrants out of service:... 5 Testing of fire hydrants:... 6 ORDINANCE HISTORY Ordinance# FH07-01, adopted May 17, 2007 Ordinance# DC09-09, adopted December 17, 2009 42077 Churchpoint Road Gonzales, Louisiana 70737 Phone: (225) 450-1002 / Fax: (225) 450-1352 Web: www.ascensionparish.net

(This page left blank intentionally for code expansion) Appendix X: Fire Hydrant Regulations Page 2 of 6

17-1001. Purpose To promulgate rules and regulations for the uniform installation of fire hydrants in the Parish of Ascension, and for the proper maintenance of such devices. BE IT ORDAINED that the following rules and regulations are hereby adopted for the uniform installation of fire hydrants in the Parish of Ascension and for the proper maintenance of such devices: 17-1002. Fire Hydrants Regulations A. It shall be unlawful to install, repair, or test fire hydrants, appurtenances, and water lines on either private or public property, except in strict conformity with the regulations of this article, the Fire Prevention Code of the Parish of Ascension and other local ordinances, rules, or regulations of the water authority serving that area, federal or state law, as amended. B. All fire hydrants, appurtenances and water lines shall be maintained in accordance to this article, rules and regulations of the water authority serving that area, as amended. 17-1003. Fire Protection and Prevention: General Provisions 17-1004. Installation: A. All fire hydrants, public and private shall be constructed and installed in accordance with specification provided by the local fire chief or his authorized representative. Prior to a development permit or building permit being issued, the applicant shall submit plans to the local fire chief for his approval for the placement and specifications for fire hydrants. Prior to the occupancy permit being issued the local fire chief shall examine the place and certify that the hydrants are installed in conformity with these regulations. The local building official shall be notified of the approval or disapproval by the fire chief or his designee. If adequate water service is not available, property owners are required to stub out where fire hydrants are to be placed and are to be responsible for paying to have fire hydrants installed at the time adequate water service is provided. B. The property owners of all newly construction apartment complexes, townhouses, condominiums, multifamily dwellings, shopping centers, and other commercials or industrial buildings or portions thereof exceeding two thousand (2,000) square feet in building area shall install and maintain, at the owner=s expense, an adequate number of fire hydrants, the location and number of which shall be determined by the local fire chief or his authorized representative. Appendix X: Fire Hydrant Regulations Page 3 of 6

C. When deemed necessary by the local fire chief or his authorized representative all fire hydrants shall be protected, if subject to mechanical or physical damage. The method of protection shall be approved by the local fire chief or his authorized representative. The means of protection shall be arranged in a manner which will not interfere with connection to or operation of the hydrant. D. Fire hydrants along all roadways shall have two 4% inch N.S.T. pumper connections facing the street side. Fire hydrants located in parking lots or others alike shall have two 4 % inch N.S.T. pumper connections as determined by the local fire chief or his authorized representative. E. Wherever the Fire Official determines that a hydrant is not readily visible to arriving fire companies because of curbside parking, features of terrain, construction, plantings, or other obstructions, the pavement shall be marked to indicate the location. This marking shall consist of the traffic lane nearest the hydrant. On paved streets, the blue reflector shall be affixed to the center of the travel lane nearest the hydrant. F. Access for apparatus to all fire hydrants shall be an approved material capable of providing emergency vehicle access and support at all times. The access shall be a minimum of twenty (20) feet wide. All access shall be maintained in a passable condition at all times. G. In addition, the installation of all fire hydrants shall be done in compliance with the following standards: 1. ANSI/American WaterWorks Association (AWWA) Standard 502-94 (or latest version) Standard for Dry Barrel Fire Hydrant. 2. ANSI/National Fire Prevention Association (NFPA) 14(03) Standard for the installation of Standpipe, private Hydrants, and Hose Systems, 2003 Edition. 3. ANSIINFPA 24 Standard for the installation of Private Fire Service Mains and Their Appurtenances. 4. ANSI/Standard 291-1995, Fire Flow Testing and Marking of Hydrants. 17-1005. Marking of fire hydrants: A. Top of the hydrant (bonnet) and nozzle caps of fire hydrants shall be painted and maintained by the owner with a different color application to indicate the water main size. Such colors shall be approved and supplied by the respective fire chief servicing the area. Appendix X: Fire Hydrant Regulations Page 4 of 6

17-1006. Placement of fire hydrants: A. The placement of all fire hydrants shall be approved by the local fire chief or his authorized representative. B. Fire hydrants shall be spaced for commercial, industrial, or multifamily buildings so that all proposed and existing buildings will be no more than three hundred (300) feet measured along traveled ways from a fire hydrant by fire apparatus. C. If a developer of a subdivision is required by the Ascension Parish Subdivision Regulations or the Ascension Parish Development Code or any other building or safety code to install fire hydrants, then fire hydrants shall be spaced for one-andtwo family dwellings so that all proposed and existing buildings will be no more than five hundred (500) feet attached directly to the public water system measured along traveled ways from fire hydrant by fire apparatus. D. A fire hydrant shall be provided within fifty (50) feet of a fire department connection for fire suppression systems. E. Hydrants shall be located no closer than forty (40) feet from any building or structure. 17-1007. Obstruction of fire hydrants: A. No person shall place or keep a fence, growth, trash, or other material near a fire hydrant that would prevent such hydrant from being immediately discernible or in any other matter hinder the fire department from gaining immediate access to a fire hydrant. 17-1008. Fire hydrants out of service: A. Notification shall be made to the fire department prior to the disconnection and the interruption of protection due to test, repairs, alterations, or additions and upon completion of such work for uses other than fire protection. B. All hydrants placed out of service shall be marked by a method approved by the fire department. Appendix X: Fire Hydrant Regulations Page 5 of 6

17-1009. Testing of fire hydrants: A. Upon completion of installation and/or repairs, fire hydrants shall be flushed in order to remove foreign materials and flow tested in accordance with the American Water Works Association Manual of Water Supply Practices (AWWA M17) and accepted by the local fire chief or his authorized representative. B. All private fire hydrants shall be flushed and flow tested biannually by the owners of said hydrant. Documentation of this activity shall be provided to the local fire department and the fire board. C. All flow test results shall be submitted to and kept on file by the local fire chief or his authorized representative. Appendix X: Fire Hydrant Regulations Page 6 of 6