Technical Information

Similar documents
REVIEW OF TECHNICAL STANDARDS AND CALCULATION METHODS FOR DIMENSIONING OF SMOKE AND HEAT CONTROL SYSTEMS IN CASE OF FIRE IN UNDERGROUND CAR PARKS

incorporating Contractors guide to car park ventilation A no-nonsense guide to the safe ventilation of underground and covered car parks

SMOKE CONTROL - NEW DIRECTIONS

Interaction of Water Extinguishing Systems and Smoke and Heat Exhaust Ventilation Systems (SHEVS)

NOVENCO CAR PARK THRUST VENTILATION SYSTEM DESCRIPTION. Pure competence in air.

GreenJet Transfer Fans

Design of Fire safety in Multi Occupancy Residential Accommodation

(h) Pesticide Application.

PERFORMANCE COMPLIANCE METHODS

technical specification smoke venting systems

El Reno Fire Department Fire Alarm Plan Review Worksheet

SEMICONDUCTOR FABRICATION FACILITIES

CHAPTER 7 ALTERATIONS LEVEL

NFPA-APSEI Fire & Security 2010

Module 7. Control of Smoke & Highlights of Code Requirements

COMPLIANCE ALTERNATIVES

COMPLIANCE ALTERNATIVES

Enclosure 4- RISK ASSESSMENT

CHAPTER 7 MECHANICAL VENTILATION AND SMOKE CONTROL SYSTEMS 7.1 AIR CONDITIONING & MECHANICAL VENTILATION SYSTEMS

Prescriptive Requirement for Smoke Control

PERFORMANCE COMPLIANCE METHODS

GUIDELINES FOR HIGHRISE BUILDING CONSTRUCTION PROJECTS (MECHANICAL VENTILATION)

PERFORMANCE COMPLIANCE METHODS

Firefighting operations on multi-tiered vehicle stacking buildings F5-13 GD

Single Zone System. One duct system Used mostly in small buildings Forced air system All spaces controlled by a single thermostat Single air return

SEMICONDUCTOR FABRICATION FACILITIES

Case Study 1 Underground Car Park

Osceola County Department of Fire Rescue and Emergency Medical Services

CARBON MONOXIDE DETECTOR, i4h-co-m330

Safety Manual Section 7 Fire/Life Safety

2012 International Mechanical Code Significant Changes. About the Significant Changes

State of the Road Tunnel Safety Technology in Japan. Hideto Mashimo 1

SEMICONDUCTOR FABRICATION FACILITIES

IMC Significant Changes Summary Tier I

TUNNEL FANS STANDARD AND HOT SMOKE

Smoke Control Design and Activation. CFAA NCA Technical Seminar 2015

The Swedish National Board of Housing, Building and Planning s general recommendations on the analytical design of a building s fire protection, BBRAD

Why is this important?

Smoke Master SMIA Compact pressurisation and smoke exhaust system

Third Runway Project APM Depot Fire Engineering Design. Presented by Ir Wilson Sau-kit TSANG

ASHRAE Safety Standards. Mechanical Rooms and Gas Detection in Commercial Applications

The Physical Environment Portal: Module 5, LS Leadership

ANALYSIS OF SMOKE MOVEMENT IN A BUILDING VIA ELEVATOR SHAFTS

IAQ Building Education and Assessment Model (I-BEAM)

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST

FIRE SAFETY INSPECTION REPORT

General Principles of Smoke Control

Fire protection documentation. CFPA-E Guideline No 13:2015 F

FIRE DEPARTMENT - RULES FOR FIRE PROTECTION IN AUSTRIA

EADQUARTERS. Technical Report One. Stephanie Kunkel Mechanical Option

HVAC OUTDOOR AIR VENTILATION STANDARD. ASHRAE Standard ASHRAE Standard

2018 IFC Update. Based on the 2018 International Fire Code, (IFC ) Goal. Objectives. Content

incorporating Guidance to Shafts for Smoke Control A useful guide to practical smoke shaft principals and specifications

IT AFEM. Table of Contents. Error! Table not allowed in footnote, endnote, header, footer, comment, or text box.

Fire Safety Concept Hotel Jumeirah

Carbon Monoxide (CO) Gas Detector March 15 GCO 300

Protecting Children from Carbon Monoxide Poisoning

Top tip No. 21 Fireman s override

How design fires can be used in fire hazard analysis

- CONSTRUCTION FIRE SAFETY STANDARDS

Following are the systems proposed as per NBC & Local Fire Authority:

SEMICONDUCTOR FABRICATION FACILITIES

30 top tips to tackle HVAC challenges No.21 - Fireman s override

Early Warning Fire Detection Engineering

WORKSHEET 2-1 THE MANITOBA RESIDENTIAL OCCUPANCY FIRE RISK INDEX FIRE SAFETY PARAMETER VALUES

5 Key Stages to Risk Assessment

Fire Prevention & Protection at SCARC

Passive House Northwest AIA CEU Provider. Aubrey Gewehr March 27, 2015

Sprinklers Modeling for Tunnel Road Fire Fighting

Fire Safety Evaluation of Existing Manufactured Educational Building Covered by Section 423 of the Florida Building Code

BOABC Level III Exams 7, 8, 9 and 10 Beginning April 1, 2015

Agency for Health Care Administration

LP GAS LEKAGE ALARM. M. G.. D. D. Wickramasinghe 1*, N. Abhayasinghe 2

Smoke Management in High-Rise Structures

Report on First Revisions with Statement June 2014 NFPA 101

How to Use Fire Risk Assessment Tools to Evaluate Performance Based Designs

System-Connected Carbon Monoxide Detectors

B. Use UT Austin specifications and equipment schedule format for HVAC equipment where available.

Fire Safety Guidelines

Laboratory Fume Cupboards

Displacement Ventilation

Fire Protection Coffee Break Training May 2016

APPLICATION FOR FIRE CERTIFICATE / FIRE CLEARANCE UNDER THE MAURITIUS FIRE AND RESCUE SERVICE ACT 2013 OFFICE USE ONLY

Application of the New Italian Fire Safety Code (D.M. 3 agosto 2015) to Case Study 3 Mall. Enrico Danzi Luca Fiorentini Luca Marmo Vincenzo Puccia

GASBLASTER LSX4 OPERATION MANUAL

F.R.A.M.E. EVENT NETWORKS used in "FRAME".

Indoor Environmental Quality

Guidelines for the Design Engineer

Some Important Aspects of Fire Safety Regulations about High Rise Buildings

Edward K. Budnick Hughes Associates, Inc. Wheaton, Maryland, U.S.A SUMMARY. that is entrained or otherwise mixed into the mass.

Fire and Extinguishing Tests on Computer Equipment

2. The Group F occupancy has have an a combined occupant load of 500 or more above or below the lowest level of exit discharge.

SPECIAL DETAILED REQUIREMENTS BASED ON USE AND OCCUPANCY

Academic and Administrative Buildings

The safe choice. Now real safety is possible and easy. The evolution of safety. Fire resistant LSOH cables. Ecology Line. Traditional standard cables

Manhattan Fire Protection District

Tighe&Bond. Groton Heights School Mechanical Evaluation. 1 Existing Conditions. 1.1 Water Service Entrance

HKIE CPD Training Course (II) 23, 25 June and 7, 9 July 2009

INTRODUCTION. JAU /JCC/JVC Series Jet Fans - for car park ventilation

NFPA 101, 2012 EDITION IMPACT ON NEW AND EXISTING HEALTH CARE FACILITIES

Transcription:

How to design easily a smoke management system? Mechanical smoke extraction for enclosed car park Car park: specificity of the smoke extraction system Car parks are nowadays integrated directly inside buildings to gain space outside. These enclosed car parks are usually underground at basement level, and thus pose a particular fire hazard due to the amount of motor vehicles and the resulting potential for fire spread. Smoke caused by such an underground car park fire represents the major killer (smoke inhalation), and consequently smoke has to be exhausted outside to let the people escape safely. Smoke Management System - Underground car park smoke extraction A car park smoke extraction system is following the same principles and goals as a corridor smoke extraction system, ie to manage the extraction of smoke, fumes and hot gases inside a compartment under fire to let the people escape safely the car park during the early stage of the fire. The role of the car park smoke extraction system is also to create a smoke free layer above the floor by removing smoke, and thus improve the conditions of safe escape and/or rescue of people with a better visibility and reduced temperature. Furthermore, the car park smoke extraction system shall give assistance to the fire brigade to restrict the expansion of smoke to other areas, locate the fire in all its stages and fight it (part of the smoke control), and to clear the car park for smoke after the fire is extinguished (smoke clearance). Whereas ventilation systems and smoke management systems are usually totally different systems with notably different ductwork, a car park smoke extraction system is also used as a car park ventilation system (same ductwork, same fans...) which is designed to remove exhaust gases produced by motor vehicles and ensure a healthy environment with acceptable indoor air quality based on the CO level. Although the users are present during a short-time in the car park (mostly 1-10 minutes), the risk of breathing polluted air can be really hazardous due to potential high concentrations of toxic gases (CO, NO2, C6H6, BaP, SO2, Ozone...). Consequently, the design of a car park extraction system has to integrate both constraints for effective pollutants removal (CO, NOx...) and safe smoke removal at high temperature. 1/7

Car N 26 park June categories 2011 & general requirements How to design easily a smoke management system? Two main types of car parks with different requirements are generally considered internationally: open car parks & enclosed car parks. Open car parks or well-ventilated car parks - Open car parks or well-ventilated car parks are usually above ground level with permanent wall openings on each level to provide cross natural ventilation. These openings are considered to provide sufficient natural ventilation for clearance of both smoke and vehicles exhaust fumes, and there is no need for automatic sprinkler system. An open car park has to comply with the following UAE Fire Code requirements which are relatively common amongst international standards: 50% of the car park perimeter shall be having permanent natural ventilation opening At least ¾ of the car park shall be within 30m of a permanent natural ventilation opening Any part of the car park shall be within 30m of a permanent natural ventilation opening The car park area shall not be more than 2230m² Such car parks cannot be more than 3 levels of parking Enclosed car parks - Enclosed car parks are usually underground, but comprise basically all the car parks which don t meet the requirements for open car parks. The different levels of an enclosed car park can be divided into compartments of 3000m² maximum (3600m² maximum for an entire level) or 6000m² if the compartment is equipped with an automatic sprinkler system. These car parks should have a mechanical ventilation to ensure an acceptable indoor air quality based on a maximum threshold limit of carbon monoxide CO, and this mechanical ventilation should perform also the smoke extraction for each compartment/zone. The smoke extraction system shall be activated automatically by the fire alarm control panel with a remote manual start-stop switch located at fire command centre or at main fire alarm control panel on 1st storey in case here is no emergency command centre in the building. Air intake shall not be less than 5m from any exhaust discharge openings. Enclosed car park Smoke exhaust axial fan & smoke exhaust duct Note: In case the car park has permanent openings on each level, equal to 2.5% of the floor area, natural air supply will be considered sufficient for the smoke extraction system. The openings shall be evenly distributed over the car park areas. For mechanical air supply, the supply airflow should be equal to 75% of the extract airflow with 10% tolerance. 2/7

Enclosed N 26 June car 2011 park & mechanical ventilation requirements How to design Key criterion easily for IAQ: a CO smoke air pollutant management level (toxic gas) system? As already mentioned, car parks have to be designed to ensure an acceptable indoor air quality based mainly on a maximum threshold limit of CO air pollutant. CO is a toxic gas easily absorbed by hemoglobin in human blood which inhibits oxygen delivery to the y causing adverse health effects varying from headache to death. The recommendations for the CO exposure limit are not consistent between various regulations in different countries, but a limit of 25 ppm for long-term CO exposure (1h) would meet almost every code and standards in USA (IMC) and Europe. (cf ASHRAE 2007 HVAC Applications Enclosed Vehicular Facilities ). In the UAE, ESTIDAMA has a specific credit requirement for Car Park Air Quality Management following the WHO Guidelines 2000 Air Quality Guidelines for Europe, 2nd Edition: The guideline values for CO are 100 mg/m3 (90ppm) for 15 minutes, 60 mg/m3 (50ppm) for 30 minutes, 30 mg/m3 (25ppm) for 1 hour, and 10 mg/m3 (10ppm) for 8 hours. The credit requirement from ESTIDAMA does not consider only CO level, but also NO2 level and PM10 level. Minimum extract ventilation rates for CO removal & smoke removal The recommendations for the minimum extract ventilation rates are not consistent as well between various regulations in different countries (prescriptive methods): o France: 900m3/h per vehicle & per compartment or 600m3/h per vehicle & per compartment if the compartment is equipped with an automatic sprinkler system o UK: 6 air changes per hour (ACH) for comfort extraction (CO removal) & 10 ACH in case of fire (Smoke removal) o USA: ASHRAE & IMC requires 1.5cfm/ft² whereas NFPA 88A recommends a minimum of 1.0 cfm/ft² According to the UAE Fire Code, the requirement is fixed at 9 ACH in the UAE for enclosed car park with total floor exceeding 2000m². Demand-control ventilation rates for day to day CO removal The simplest (but rarely used) option is to run the system at a constant speed, providing the minimum extract ventilation rates throughout the car park. To reduce energy costs, a permanent CO detection system shall be used to allow the system to run at a reduced ventilation rate in periods when vehicle movements are low. By using a single output detector, a two-stage control (ex: On/Off) can be provided typically switching before the maximum threshold limit of CO. By using variable output detectors, the system can even modulate to match the ventilation rate to the car park usage. A variable air volume (VAV) control using two-speed fans (half speed & full speed) based on input from CO sensors can be used as an efficient way to increase energy saving. 3/7

CO detection system CO sensors are placed usually at 1.5m above floor level and may guard a maximum area of 200-400m². The height of How 1.5m is regarded to design as the breathing easily zone and a smoke therefore the height management to measure the concentration system? especially considering that density of CO is similar to Air. Note: In case of LPG detection, the LPG sensors should be placed at 150mm above floor level as LPG is much heavier than air and therefore measured just above the floor. Enclosed car park & smoke extraction requirements The minimum extract ventilation rates for smoke extraction in the UAE has been fixed at 9 ACH in the UAE for enclosed car park with total floor exceeding 2000m². Smoke detection system An early detection of smoke is fundamental to warn occupants and let them escape safely the car park. The detection will also give a signal to the ventilation / smoke extraction system to work on the highest exhaust airflow. As well, the fire brigade can automatically be informed and start faster the fire fighting. Smoke detectors should be located at ceiling height as hot buoyant smoke will rise naturally. In case of use of a sprinkler system and if activated by the fire alarm control panel, the sprinkler system activation should be delayed after the correct activation of the smoke extraction system to allow the people to escape safely the car park. Indeed, the cooling effect of the sprinkler system on the smoke will make it fall down and then cause a loss of visibility to the occupants. Moreover, the shock caused by the sudden onset of cold water might increase the anxiety of the occupants (panic). The sprinkler system could be activated by heat sensing which would provide an automatic delay. This delay has also to be reasonably short to make the sprinkler system efficient enough to fight the growing fire. 4/7

Smoke exhaust fans The purpose of the smoke exhaust fan is to overcome the pressure loss of the ductwork and ensure the correct minimum How extract airflow to design rate at high temperature easily in a case smoke of fire. Smoke management exhaust axial fans, duct system? or wall mounted, are mostly used as they are well adapted for low pressure and high airflows - Each compartment/zone should have its own exhaust fan system. The system should have at least 2 exhaust fans, each providing 50% of the extract, with a secondary power supply to operate in the event of a main power failure. - Exhaust fans shall be capable of operating effectively at 400 C for 2 hours (F400 120 as per EN 13501-3 classification). -Exhaust fans should be spaced at least 3 meters away from any parked vehicle to avoid any failure due to the direct effect of fire. Where this distance cannot be respected, the installation of a protection enclosure should be made of incombustible material with fire resistance equal to the fire resistance of the upper slab (max. 1 hour). Smoke Exhaust Axial Fan for Car Park Type Model Standards Fire Resistance Speeds Key Features Direct/Belt driven Max Airflow Axial Fan HELIONE EN 12101-3 (CE) 200 C or 400 C - 2h 1 or 2 (2 speeds recommended) direct driven 72000 m3/h Smoke exhaust ducts Smoke exhaust ducts shall be manufactured from heavy gauge steel (1.2mm thick). Supply & extract grilles location Concerning the location of supply air inlet and extraction air outlet, the key principle is to have a satisfactory sweeping with expected air flow rate from supply air inlet to extraction air outlet to ensure an efficient smoke extraction. This is the same principle as for corridor smoke extraction where the cold fresh air has to help and push the hot buoyant smoke through the extract duct: Sweeping method & smoke free layer Supply & extract grilles (GFA 007 & AC 121) Consequently, for a good performance of the smoke extraction system, supply air inlet shall be located at the bottom of the compartment (openings in facade or duct) when the extract air outlet shall be installed on the upper part of the compartment. They shall not be installed in vehicle entrance / exit ramps. These requirements are really important to ensure a correct smoke extraction, and thus a safe evacuation of the occupants. The system will ensure correct comfort ventilation as well as the fresh air will be supplied from down and will replace the polluted air which will be extracted from the top (natural movement). 5/7

Note: As per the French prescriptive method for natural air supply, the air supply duct section should be at least equal to the free area of the air inlets and there should be a maximum ratio Height/Length or Length/Height of 2. The air inlets should be 9dm² for extraction airflow of 900m3/h per vehicle and per compartment or 6dm² for extraction airflow of 600m3/h per vehicle and per compartment. How to design easily a smoke management system? Note: A common requirement from UK is to have extract grilles 50% at high level and 50% at low level with supply / replacement air from natural ventilation or mechanical air supply ductwork at high level if necessary. This system using a distribution by air mixing can be correct for comfort ventilation (CO removal), but this system will have bad performances for smoke extraction as only 50% of the grilles (high level ones) will basically extract the smoke which will be then diluted in the ductwork with replacement air coming from the 50% grilles on the bottom part. This system should be avoided and replaced by a system with extract grilles on the top and supply grilles on the bottom to ensure the safe escape of the people inside the car park. This is the 1st priority of a smoke extraction system. As already described, here are the 2 main priorities of a smoke extraction system: 1. Safe escape of the occupants with smoke free layer, better visibility, reduced temperature & expansion restriction 2. Help fire fighters to locate the fire and fight it, and then clear the smoke Maintenance & regular checking Although the ventilation system will function on a daily basis, the maintenance and servicing of the car park smoke extraction system is essential and should be made mandatory. A regular checking should be performed every month to check any potential defective equipment. A preventive maintenance should be scheduled every 6 month or every year to check all moving parts with potential mechanical and corrosion damage, overheated parts... A full functional test should be performed every year to check the full system operation in case of fire. 6/7

These conventional methods and requirements described here above are prescriptive. They present an easy way to achieve a correct and forecasted level of safety for occupants to escape an enclosed car park, and they should work basically for any common type of enclosed car parks. How to design easily a smoke management system? For any information or enquiry, please contact us! www.aldes.ae And let s come to visit our factory and showroom! 7/7