Installation and Maintenance Requirements

Similar documents
Watermist Systems. Versatile, Affordable Water Mist Fire Suppression. your TRUSTED partner in fire safety

Safer.Smarter.Tyco. Watermist fire protection Technology you can trust

Fire protection for buildings

Additional Requirements for Watermist Systems Protecting High-rise Buildings

Inspection of Fire Sprinkler Systems. NFPA 25, Inspection, Testing & Maintenance of Water Based Fire Protection Systems

Approved products and systems for water mist systems and VdS 3188 for planning and installation

The requirements of BS Watermist Fire System standard and how to demonstrate compliance

Tudor House, Kingsway Business Park Oldfield Road, Hampton, Middlesex, TW12 2HD Phone: +44 (0) Website:

MSC Guidelines for Watermist Fire Suppression Systems Procedure Number: E1-03 Revision Date: 02/16/2017

HI-FOG for buildings. Technical introduction. Protecting people, property and business continuity. Jussi Tiainen

I wish I could protect my business with the most suitable Water Mist solution to fit my needs.

Maintenance of Fire Systems

Becoming an Expert on Dry-pipe, Preaction, and Deluge Sprinkler Systems

Application of BS 8489 to the Protection of Generator Enclosures. IWMA, BRE 22 nd March 2017 Dr Tim Nichols CPhys FIFireE


MORE THAN JUST FIRE PROTECTION

SECTION WET PIPE FIRE PROTECTION SPRINKLER SYSTEM

Case study: EconAqua water mist sprinkler system

MAINTENANCE AND TESTING OF FIRE SPRINKLER SYSTEMS

Performance Based Fire Protection With Water Mist

MORE THAN JUST FIRE PROTECTION

HOW COMMERCIAL FIRE PROTECTION SPRINKLER SYSTEMS REALLY OPERATE

Revision May All designs must be submitted to FM Global for review and approval prior to issuing such for bids.

VELMIST. System Mgły Wodnej Niskociśnieniowej

STANDARDS FOR ACTIVE FIRE PROTECTION. Stewart Kidd Loss Prevention Consultancy Ltd

FIRE SAFETY POLICY LEEDS METHODIST MISSION. Oxford Place Centre

PREVENT SYSTEMS WHEN SAFETY IS TAKEN SERIOUSLY

Owner/Operator Guide for Successful Sprinkler and Fire Pump Systems

Legal Requirements. There is no general legal requirement to install sprinklers. in places of work

MAINTENANCE AND INPSECTION OF FIRE PROTECTION SYSTEMS AND APPLIANCES

Corrosion in Fire Sprinkler Systems Increasing Your Liability, Increasing Your Costs, and Shortening System Life

Refer to the specific sprinkler or spray nozzle technical data pages for sprinkler listings and approvals.

Element C3.4 Fire Fighting Equipment

COBB COUNTY SCHOOLS /S&A % BID DOCUMENTS 2/18/11 SECTION SPRINKLER SYSTEM

EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD

EXHIBIT D ATTACHMENT G - UNIT PRICING DMS-14/15-039B - SIMPLEXGRINNELL, LP FIRE SPRINKLER SYSTEM INSPECTIONS YEARS 1-5

SECTION : FIRE PROTECTION SYSTEMS

Fire Protection of Hotels. With SEM-SAFE High-Pressure Water Mist System

Box-in-Box Cold Storage Fire Protection Options

UNIVERSITY OF MISSOURI Fire Protection System Design 2016 Q1

The Next Generation of Foam Fire Suppression. Automatic CAF Fire hose reel system FEATURES

Water Mist System. Principle of Water mist evolves from combination of 3 main effects:

Draft FPA Australia Technical Specification for Public Comment FPAA101H DRAFT

Case Study: Water Mist in a historic Place. Het Loo Palace, Apeldoorn, NL

Gulf Industrial Systems Co. Fire, Safety & Security Systems

Water mist fire suppression systems. Minifog ProCon Low-pressure water mist system

w-fog RG-SYSTEMS W-FOG WATER MIST CO-OPERATI

Statutory Compliance Checklist

A. This section includes design and performance information for fire protection and suppression systems.

Enclosure 4- RISK ASSESSMENT

FIRE PROTECTION. 1. Vertical fire pumps shall not be used at the University.

Watermist Systems Compliance with Current Fire Safety Guidance

Public Comment No. 2-NFPA [ Section No ]

Fire Sprinkler Courses

Deluge & Preac tion Systems

WATER MIST CONVENTION AND EXHIBITION

F I R E S A F E T Y R E G I S T E R

How to know if a residential or domestic water mist system is performance compliant to BS 8458:2015?

Model F1FR Series Quick Response Standard Spray

Water Mist Fire Suppression

AUTOMATIC FIREFIGHTING SYSTEMS IN HOSPITALS

MINOOKA FIRE PROTECTION DISTRICT Fire Prevention Bureau Fire Inspector Rodney Bradberry Plan Review

Fire Suppression Systems

LA AUDIT ASSISTANCE SURVEY: Pre-survey checklist

Health, Safety and Wellbeing Management Arrangements. Core I Consider I Complex. Fire Safety. Health, Safety and Wellbeing Service

ISLE OF WIGHT FIRE & RESCUE SERVICE

False Sense of Security???

1.1 Refer to Section for General Mechanical Requirements. 1.3 Refer to Section for Pipe and Equipment Identification Requirements.

White Paper. The Victaulic Vortex Fire Suppression System Fire Suppression for Electrical and Electronic Applications

and Sprinkler System in Resalat Tunnel of Tehran

TOTALPAC2 Integrated Fire Protection System

FIRE PROTECTION SYSTEMS IN BURJ KHALIFA. By NAFFCO Fire Protection

DIVISION 21 FIRE SUPPRESSION FIRE SUPRESSION

Global Property. QUARTERLY FIRE PROTECTION EQUIPMENT INSPECTION REPORT Date of Inspection Location:

Fire Safety Register

Approval of water mist systems in buildings

FIGHTING FIRE as easy as blowing out a match

SECTION DRY PIPE SPRINKLER SYSTEMS MODEL F SERIES DRY VALVE

Standards and third party certification

American Society of Safety Engineers Professional Development Conference June 9-12, Fire Protection. Stephen J.

REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT

DIVISION 21 FIRE SUPPRESSION

COMPANY BROCHURE. Fire Protection for Industrial Facilities and Buildings

that sense s of ecurity

WATER MIST SYSTEMS. Table of Contents

The metering orifice is sized according to the type and percentage of concentrate used and is also secured with a stainless steel retaining ring)

Attachment 1. to ClassNK Technical Information No. TEC-1077 Isle of Man Ship Registry Manx Shipping Notice SOLAS II-2 The Maintenance and inspection o

Sprinkler systems. A presentation for fire brigade staff

Branch Solution Wood based panel plants. Fire protection solutions for wood based panel plants

Fire Risk Assessment

INSTITUTIONAL QUICK RESPONSE FLUSH HORIZONTAL SIDEWALL SPRINKLER VK412 (K5.6) TECHNICAL DATA

Loss Prevention Standards

PLAN REVIEW CHECKLIST

STATE FIRE MARSHAL S REQUIRED FIRE PROTECTION SYSTEMS NARRATIVE REPORT

This document is a preview generated by EVS

Sprinkler System Installer Level 2

CHAPTER 61G15-32 RESPONSIBILITY RULES OF PROFESSIONAL ENGINEERS CONCERNING THE DESIGN OF FIRE PROTECTION SYSTEMS

Attachment 1. to ClassNK Technical Information No.TEC-0764 Malta Maritime Authority Date Revised 28 August 2008 Page 1 of 10 This Administration Requi

CO 2 Fire Extinguishing Systems

security WHAT MAKES US DIFFERENT? We Place A Huge Importance On Integrity.

Transcription:

Installation and Maintenance Requirements Water Mist Systems in Buildings John Sinclair Compco Fire Systems

This Presentation Will Cover: 1. Water mist systems for buildings and local applications 2. Products available for Fire Suppression systems today 3. The design and installation of water mist projects 4. Hazard Analysis 5. Products used in Low and High pressure water mist systems 6. Testing and Commissioning 7. Living with a system 8. Future modification and refurbishment 9. Maintenance and after care 10. As a Specifier- Summary

1. Water Mist Systems for Buildings & Local Application Offices Laboratories Hotels Hospitals Care Homes Car parks Car stackers Plant areas Heritage Sites Industrial Automotive

Applications Schools Museums Archives Hospitals Tunnels Turbines Generators Computer Rooms Local Applications

2. Products Available for Fire Suppression Systems Today Low Pressure Water Mist High Pressure Water Mist Traditional Fire Sprinklers Gas Suppression Wet and Dry Risers Combination of the above

3. Design & Installation of Water Mist Projects Standards: BS8489 (commercial), BS8458 (residential), CEN/TS 14972, VDS, FM5566, NFPA750 Hazard classification Engineered solutions Object protection Volumetric considerations for nozzle selection Survey CAD design Full hydraulic calculations (Hazen-Williams formula for LPWM and Darcy-Weisbach for HPWM) Operating pressure up to 12.1 Bar for LPWM and over 34.5 Bar for HPWM Health and safety considerations

Design & Installation of Water Mist Projects Size of plant space for water supplies can be less Allow for smaller pipes ease of Coordination Less water damage risk If Retro fitting a system would be the clear choice Longevity of System - High pressure water mist expectancy of stainless steel is 50+ years Quick and simple installation Advanced technology of firefighting system since design of sprinklers in 1883 Highly technical product without being complicated

A project COMPCO has been involved: Example Assisting the client to re design and reduce plant space on site and less issue with planning Adding more high value car parking space by going for High Pressure Water Mist

4. Hazard Analysis Before designing a Watermist system the following to be identified: Volume Occupancy Object to be protected A Hazard Analysis is carried out to establish exact nature of the potential fire hazard The main fire performance objective of Watermist system under test is: Fire Extinguishment Fire Suppression Fire Control As appropriate for the volume or object being protected

5. Products used in Low and High Pressure Systems & Water Supplies Full holding capacity water tank: Galvanised steel sheet, concrete, GRP, etc. Reduced capacity break tank reliant on town s main infill Towns main with booster Water cylinders with nitrogen propellant Generally a smaller room and plant footprint needed, the higher the pressure is

Water Supplies Single duty pump Duty and stand-by pump Multiple pump arrangement (more common for HPWM) Electric and diesel motors UPS power packs

Control Valves Wet Dry Pre action Deluge Zone valves Foam enhanced

Pipes & Fittings Low Pressure Water Mist Galvanised medium grade steel pipe Grooved, flanged & screwed fittings CPVC Glued fittings Stainless steel Press fittings Copper

Pipes & Fittings High Pressure Water Mist Stainless steel AISI 316 or higher Compression fittings (ferrule or flare) Mechanically pressed connections Flanged fittings

Pipe Fixings / Anchors Suitable for each application depending on weight and structure to fix into

Nozzles The array of heads are similar to traditional sprinklers Automatic Open Upright Pendent Ceiling c/w rosettes Sidewall Undercover Dry Pre action Floor Etc. Multi choice colour

6. Testing & Commissioning Each system shall be subjected to an air & hydraulic test in accordance with manufacturers guidelines Once all the systems are completed the systems shall be commissioned, performance tested and left live as per BS 8489

7. Living with a Water Mist System Typically High Pressure water mist pipes are charged with a standing pressure of 20 to 35 BAR. Only upon activation of the system, the pumps will increase to operating pressures. The potential energy in pipes at such small water volumes and pressure is very low. Low Pressure systems would be static at 8 to 14 BAR typically as an approximate indication

8. Future Modification & Refurbishment Simple and cost effective changes can be carried out on any water mist system Zone valves allow partial isolation of a building Easy drain downs (Due to less water in systems) Simple fittings and pipes to ease modifications in situ Generally faster installation due to pipe sizes and fixings

Life Expectancy Exceeds 50 years Subject to appropriate maintenance and equipment selection Robust design for the pumps Stainless steel pipe: 50+ years CPVC pipe: 25+ years Galvanised steel pipe: 40+ years

9. Maintenance & Aftercare The maintenance of the water mist is set out specifically by each manufacturer s design guides but similar to traditional sprinklers: Valves need servicing Pumps need flow and pressure checks Strainers need cleaning Bells and flow switches need checking System status and condition need recording Building hazards and products need auditing

System Operation & Maintenance Manuals To be provided on completion as per BS 8489 Description of the system Operation of the system Testing requirements & procedures Dealing with emergency & fault findings Record drawings and hydraulic calculations Commissioning sheets

Inspections & Regular Checks Same as traditional sprinklers, all fire fighting water mist systems must be regularly inspected by competent and trained engineers Including: Weekly Monthly Quarterly Half yearly Yearly Three yearly Ten yearly routine

Replacement Parts High and Low pressure water mist manufacturer operate with approved and certified contractors. Must be trained and approved by them Spare water mist nozzles should be available within the premises protected it is important again to use a reputable manufacturers product

Make Sure: 10. As A Specifier - Summary Products used have recognised third party approvals (UL/VDS/LPC/NFPA/FM) Products are from reputable suppliers with long track record of manufacturing fire engineering products The Contracting Company has proven track record of projects The products offered have been tested to meet the fire risk of your application

COMPCO Fire Systems Cleeve House Malvern Road Worcester WR2 4YX Telephone: 01905 741600 Thank You @CompcoFire COMPCO Fire Systems