ECLIPSE AIR HEAT BURNERS Series AH, DAH, TAH & CAH

Similar documents
ECLIPSE AH-MA BURNERS. Air Make-Up Burners. Designed for trouble-free make-up or process air heating. Ready for the world

"NP" & "RG" AIRFLO. In-duct firing line burner

Eclipse AirHeat Burner

Specifications of V-Line burners

Series LV AIRFLO. In-duct firing line burner

Eclipse AirHeat Burners

ECLIPSE INFORMATION GUIDE

APX. Nozzle-mix line burner

Eclipse AirHeat Burners AH Series version 2.00 (Patent Pending)

NMC Nozzle Mix Gas/Oil Combination Burners

DELTA-TE III. Nozzle-mix line burner

"HC" AIRFLO. In-duct firing line burner

Lanemark Midco HMA2A Series Air Heating Burner and DB Duct Burner System Application Manual

Design Guide 111 9/25/2008. Eclipse Winnox Burners WX Series Version 1

INDITHERM. Low temperature gas burners

Design Guide /12/2008. Eclipse RatioAir Burners RA Series Version 1

INDITHERM. Low temperature gas burners

V-Line. Nozzle-mix line burner

ECLIPSE INFORMATION GUIDE

Eclipse ER Indirect Air Heater

Energy saving and better heat control.

Design Guide No /01. RatioMatic Burners. RM Series Version 3.10

INDUSTRIAL MICRODIFFUSION OIL BURNERS

Ecomax. Direct-Fired Self-Recuperative Metallic Gas Burner. Features

PYRO-LINE BURNERS 126LX 6LE 12LS DESCRIPTION MODEL: 3201

DESCRIPTION, CAPACITIES, SPECIFICATIONS, APPLICATIONS

DESIGNING A COMBUSTION AIR/GAS PRE MIX SYSTEM FOR RED RAY INFRARED PROCESS BURNERS

SECTION DIRECT GAS-FIRED INDUSTRIAL HEATING AND VENTILATING UNITS

OPERATING AND MAINTENANCE MANUAL

Line Pressure ( w.c.) Gas Supply Min. Max. Pressure ( w.c.) Natural Gas Propane Gas

Eclipse RatioMatic Burners

SUBMITTAL SCHEDULE & DATA

1500 SERIES SMALL CAPACITY ULTRA 2 LOW NO X TM BURNER

UV Scanner. Model Specification. Introduction. 854 Instruction Manual

PACKAGED METALLIC BURNERS

EXCESS AIR BURNERS XNM SERIES FEATURES APPLICATIONS DESCRIPTION. Bulletin E3502 rev05 31/01/00

Bert Uneken, Field Engineering Manager Ruben Kranenburg, Technical Support

STS-JZ (premierschwank) POSITIVE PRESSURE SERIES GAS FIRED INFRA-RED TUBE HEATERS

Bosch Greentherm T9800 SE 199 Gas Tankless Water Heater

Installation Instructions

Eclipse 90 UV Scanner Model A Version 1

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS SL/SLV SIRIUS LINEAR RANGE HIGH EFFICIENCY CONTINUOUS INFRARED SYSTEMS

Engineering Bulletin. Gas Heat. for M-Series and T-Series Climate Changer Air Handlers CLCH-PRB010-EN. March 2004

VF/VG700 Jumbo. Construction Heater. Installation and Maintenance Manual

BURNERS/ FLARES. VAREC BIOGAS 244W Series WASTE GAS BURNER & IGNITION SYSTEM

PBG PACKAGED GAS BURNER

INSTALLATION, OPERATION & MAINTENANCE MANUAL INDIRECT GAS-FIRED DUCT FURNACE

Heating Systems. Brooders, Space Heaters and QuadRadiant Heaters

Specifications of MULTIFIRE burners

NMG NOZZLE MIX GAS BURNERS

Direct Fired Heater Model AD Specification

C1050ES Tankless Water Heater

FLAT FLAME AND EXCESS AIR BURNERS

Cumberland Heating Systems

U n i t H e at e r s

Design and Application Details

Gas-Fired Indoor and Outdoor Duct Furnaces

SECTION GAS-FIRED RADIANT HEATERS

INFRARED RADIANT HEATERS

Burners Flares Incinerators Vapor Combustion

Heating Systems. Brooders, Space Heaters and QuadRadiant Heaters

A. American National Standards Institute (ANSI): Establishes requirements applicable to certifying direct gas-fired heaters.

CONVERSION TO PROPANE MANUAL M-Series Condensing Boiler. Wall-Mounted, Gas-Fired Boiler

940ES Tankless Water Heater

Model UDAP. Power Vented, Low Static Axial Fan Commercial/Industrial Unit Heaters DESCRIPTION STANDARD FEATURES OPTIONAL FEATURES - FACTORY INSTALLED

iq251, Gen II Submittal Data

UV Flame Supervision System

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS DU/DUH DUAL OUTPUT RANGE INFRARED TUBE HEATERS

SERVICE AND INSTALLATION MANUAL MODELS HDO(H) OIL FOR YOUR SAFETY

Installation Instructions

Take Charge of Your Commercial Water Heating with the New Commander Series from Bradford White Bradford White s Commander Series The Commander Series

CYLINDER NOT INCLUDED

LFL Series Burner Flame Safeguard Control

Gas Safety. Syllabus. For 120kW. Class B gas fitter. Certificate of qualification examination

Installation Instructions

940ES Tankless Water Heater

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FOR GAS FIRED OVEN

NFPA 86 Commitee Inputs Page 1 of 45

Eclipse ER Indirect Air Heater

SERIES. 10 year limited warranty on Burner Core 5 year limited warranty on All combustion and. 2 year limited warranty on All Burner Controls

Design Guide No. 330, 10/02 Immersion Burners

Section (CSI ) I-Series Drum & Tube (04/23/10) Indirect-Fired Heating & Ventilating

STR-Series Indirect-Fired Air Turnover Units

PRE-PLANNING GUIDE for the Linear Burner System

Product Data. 58EFA Horizontal Gas Furnace. 50, ,000 Btuh Input

Clean Heat. Clean Air. PRODUCTGUIDE

HVAC HEATING PRODUCTS

KIC Air Curtains. Technical Guide

SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER

Ronald Sigmond 26 Oct 2016 FLAME MONITORING, GAS HANDLING SYSTEMS AND BURNERS

DIVISION FINNED WATER-TUBE BOILERS

ELECTRONIC FLAME SUPERVISION MULTI-BURNER

KEES, INC. Installation & Maintenance Manual DFG Series Direct Gas Fired Make-up Air Heaters. Table of Contents FOR YOUR SAFETY.

90 HIGH EFFICIENCY UPFLOW GAS FURNACES

Revitalize Building Mechanical Systems (4619)

DIVISION FINNED WATER-TUBE WATER HEATERS

Process Heat Equipment & Combustion Field Services Guide

GAS-FIRED UNIT HEATERS RESIDENTIAL, COMMERCIAL & INDUSTRIAL

Module 5: Combustion Technology. Lecture 38: Combustion Burners

Transcription:

ECLIPSE AIR HEAT BURNERS Series AH, DAH, TAH & CAH U.S. Reissue Pat. No. 26,244 Canadian Pat. No. 743,782 Spec 140 11/4/03 AH, Front View Data 140-1 AH, Back View Data 140-1 TAH Data 140-3 DAH, Blower Down Data 140-2 CAH Data 140-4 Eclipse Air Heat Burners are line type burners ideal for generating large volumes of clean, hot air. Applications include ovens, dryers, fume incinerators, and similar industrial equipment. The AH models feature an integral combustion air blower mounted on the back of the burner s steel case. By supplying the correct air volume and pressure to the burner, the blower allows stable operation over a wide range of duct velocities without installing a profile plate around the burner. Low NO x, CO and aldehydes. Exceptional flame stability with duct velocities from 500 to 6000 fpm (2.54 to 30.48 m/s.) No profiling required. Up to 40:1 gas turndown. Inputs up to 1,000,000 Btu/hr. per lineal foot of burner (962 kw/m) As little as 10% excess air at high fire; when mounted on the duct wall, no oxygen is required from the process airstream. Wide range of configurations, packages, and accessories.

Specifications Input: Fuels: 1,000,000 Btu/hr. per lineal foot (962 kw/m). Natural gas or 100% propane vapor. Call Eclipse for information on using other fuels. Gas Turndown: 40:1 Pilot Input: Approximately 25,000 Btu/hr. (7.3 kw) Pressure: 800,000 Btu/hr/ft. (769 kw/m): Nat. Gas: 2.2" w.c. 5.5 mbar Propane: 0.9" w.c. 2.2 mbar 1,000,000 Btu/hr/ft. (962 kw/m): Nat. Gas: 3.5" w.c. 8.7 mbar Propane: 1.3" w.c. 3.2 mbar Gas pressure shown is a differential measured between the gas inlet and a tap on the duct wall 10" to 20" (254 to 508 mm) downstream of the burner. Ambient Temp. Limits*: 40 to +104 F 40 to +40 C Downstream Temp. Limits: 1500 F 815 C Flame Length**: 800,000 Btu/hr. (769 kw/m): 28" 0.71 m 1,000,000 Btu/hr. (962 kw/m): 46" 1.17 m Piloting: Flame Monitoring: Motor: Materials: Emissions Integral spark-ignited pilot; ignition plug included. Flame rod supplied. UV scanner adaptors are available. For UV scanners, Eclipse recommends a flame monitoring system that terminates the ignition spark and proves the pilot flame without spark prior to opening the main gas valves. Burners over 5 lineal feet include flame supervision at the far end. If pilot ignition is being used, two flame supervision units are required; one for the pilot and one for the far end. If using direct spark on the main flame, only flame supervision at the far end is required providing that ignition can be accomplished within 15 seconds. (Reference NFPA 5-9.2.2) CGA requires two flame rods on burners over 36" long (914 mm). Use a flame monitoring endplate (see Data 140-6) to mount a second flame rod on the end opposite the gas inlet. Standard: 230/460/3/60 TEFC. Other motors can be supplied. All portions of the burner exposed to flame are cast iron or #321 stainless steel. Emissions performance depends not only on the burner, but also other factors such as chamber temperature, chamber design, and heat loading. For estimates of emissions performance in your application, call Eclipse. Packaging Options: Available with complete valve trains and control systems. AH burners and systems can be supplied mounted on duct sections as specified by the customer. Call Eclipse for information on custom packaged systems. Models: Model Description Data Sheet AH Line-shape, blower mounted on rear Data 140-1 DAH Line-shape, blower mounted on bottom Data 140-2 TAH I -shape, blower mounted on rear Data 140-3 CAH Cross-shape, blower mounted on rear Data 140-4 Related Information: Blower and motor specifications Data 140-5 * Based on blower motor limitations. ** Based on parallel air flow. If mounted in a cross flow, then flame will be shorter. CAUTION: It is dangerous to use any fuel burning equipment unless it is equipped with suitable flame sensing devices and automatic fuel shut-off valves. Eclipse can supply such equipment or information on alternate sources. 2

In-Duct Mounting Arrangements Sealed Duct Press: +0.2" to 0.5" w.c. +0.5 to 1.2 mbar Slot-Fired Duct Press: 0" to 0.5" w.c. 0 to 1.2 mbar Min./Max. Velocity: 500 to 6000 fpm 2.54 to 30.48 m/s Optimum Velocity: 1000 to 4000 fpm 5.08 to 20.32 m/s Provide at least 3" (76 mm) clearance between burner and top, bottom and sides of the duct. Profile plates are not required for good burner operation, but uniform velocity must be maintained for full length of burner. If velocity is not uniform, profile plates can be used to correct this condition. Guidelines for All Mounting Arrangements Center the burner in the duct. Allow a minimum of 46" (1168 mm) from burner to nearest point of possible flame impingement at an input of 1,000,000 Btu/hr. (962 kw/m). On burners longer than 36" (914 mm), use a hanger or a pedestal to support the blower and motor. Min./Max. Velocity: 500 to 6000 fpm 2.54 to 30.48 m/s Optimum Velocity: 1000 to 4000 fpm 5.08 to 20.32 m/s 3

Burner Firing Arrangements The AH Burner can fire in any direction. Flow through the burner s check valve, however, must be horizontal. A guide for identifying some standard arrangements is shown below. Be sure to indicate the appropriate number arrangement when ordering. If no arrangement is indicated, No. 1 will be furnished as standard. No. 2 Horizontal Firing No. 1 (Standard) Vertical Firing Up Vertical Firing Down No. 5 No. 6 No. 4 No. 3 On End Firing Blower Motor Up No. 7 On End Firing Blower Motor Down No. 8 No. 10 No. 9

Offered By: Power Equipment Company 2011 Williamsburg Road Richmond, Virginia 23231 Phone (804) 236-3800 Fax (804) 236-3882 www.peconet.com