CA 134. Piezoelectric accelerometer. IECEx NEPSI TIIS KGS. » From the Vibro-Meter product line» Vibration monitoring over a wide temperature

Similar documents
CE110I. Piezoelectric accelerometer with integrated electronics. IECEx

for CE 134 CCSAUS certificate Meggitt SA Route de Moncor 4 PO Box 1616 CH Fribourg Switzerland Title page EN

ccsaus certificate: for GSI 127 Meggitt SA Route de Moncor 4 PO Box 1616 CH Fribourg Switzerland Title Page

New Sensing products of Meggitt Group. Moscow - October the 23 rd

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor

INSTRUCTION & SERVICE MANUAL

UL HAZARDOUS LOCATIONS SERVICES

Inductive slot sensor

ORIGA-SENSOFLEX Displacement Measuring System for Cylinder Series OSP-P

Guide to Hazardous Location Approvals: MICRO SWITCH Hazardous Area Limit Switches

MODEL 4000A & 4001A ACCELEROMETER

Guide to Hazardous Location Approvals:

Erik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories

Drive Technology \ Drive Automation \ System Integration \ Services * _0817* Inquiry Forms for Explosion-Proof Gearmotors

Gas cylinder scale Model GCS-1

DP86 Constant Voltage with Fitting

Meggitt Sensing Systems Monitoring the future

M7100 Pressure Transducer

RPS/DPS High Accuracy Resonant Pressure Sensor. GE Measurement & Control. Features:

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

GTF 103-Ex. GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26. Temperature Probe for potentially explosive atmospheres

standards: standards:

D5100 Industrial Differential Pressure Transducer

Technical Data. General specifications. Rated operating distance s n 5 mm

Switches & Sensors FOR VALVES & ACTUATORS

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Temperature Measurement Transmitters for field mounting

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

... RD0-TI-Ex8.FF.* Temperature Multi-Input Device for Cabinet Installation. Features. Assembly. Function. Connection. Zone 1

The information contained in this document is the property of Meggitt Sensing Systems and is proprietary and/or copyright material.

MODEL 834M1 ACCELEROMETER

SmartPower Solutions. Quick Start Guide , Rev CA March 2015

MSP340 Pressure Transducer

condition monitoring WP4086 Condition Monitoring System The WP4086 CMS System surveys vibrations with up to 8 external accelerometers

Certification Supplement Manual

Rosemount 3490 Series

Immersion heaters for ATEX/IECEx hazardous areas or in non-atex version

Druck DPI 705/DPI 705 IS Series

WP4086 Condition Monitoring System

OPERATION MANUAL Model 8011 & mA

INSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Rosemount 3490 Series 4 20 ma + HART Compatible Controller

Technical Data. Dimensions

U86B. Urea Dosing SPECIFICATIONS FEATURES APPLICATIONS

GETTING STARTED GUIDE NI RTD, 0 Ω to 400 Ω, 24 Bit, 400 S/s Aggregate, PT100

D5100 Industrial Differential Pressure Transducer

Intrinsically Safe, NEMA 4, Type 4X, IP67 Loop-Powered Meter

Ex Long & Short stroke LPI POSITION TRANSMITTER MKII For linear position measurement in compressors

Intrinsic Safety. Intrinsically Safe Solutions. Accurate Weighing in Hazardous Areas

SmartPower Solutions [ SmartPower Solutions. Quick Installation Guide , Rev AC January 2012

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC

Certification Supplement Manual

GETTING STARTED GUIDE NI TC, ±78 mv, 24 Bit, 75 S/s Aggregate

FDOOT241-A9-Ex Multisensor fire detector

Installation guide for hazardous areas

INSTRUCTION MANUAL. D2xB1XH1 & D2xB1XH2 Xenon Beacons For use in Hazardous Locations

Model 144H. Product Data Sheet , Rev DB February Content

Meggitt Sensing Systems vibration monitoring solutions. Wilcoxon Research short-form catalog

Circulation heaters for ATEX/IECEx hazardous areas or in non-atex version

OPERATION MANUAL MODEL & ACCELEROMETER

RADAR LEVEL GAUGE SPECIAL SAFETY INSTRUCTION

Duct heaters for ATEX/IECEx hazardous areas or in non-atex version

Product ID. General. TE CONNECTIVITY SENSORS /// EXxxHyy Ex-Atex & NA 09/2017 Page 1

IECEx TEST REPORT IEC Explosive atmospheres Part 0: Equipment General requirements

DB5 Intrinsically Safe Sounder Type DB-5

HAUBER-Elektronik. Product overview. Condition monitoring Mechanical protection in compliance with DIN ISO 10816

Instruction VIBROCONTROL 850. Single channel vibration monitor. Keep it accessible for future reference.

Intrinsically Safe Transmitters, Option Code 2n

Technical Data. Dimensions

INTRINSICALLY SAFE Pressure Transducer / Transmitter AST4400

MODEL ACCELEROMETER

GETTING STARTED GUIDE NI AI, ±29.4 mv/v, 24 Bit, 10 ks/s/ch Simultaneous, 350 Ω Quarter-Bridge Completion

Model 144H. Product Data Sheet , Rev DB February Content

Michael J. Caron, Test Engineer. Lee R. Senne, Test Technician. Kent L. Erickson, Dynamics Division Manager

OOH740-A9-Ex Multi-sensor fire detector

SmartPower Solutions. SmartPower Solutions. Product Data Sheet , Rev AC January Contents

OOH740-A9-Ex Multisensor fire detector

Compliance with EN : 2006 Electrical apparatus for explosive atmospheres Type of Protection «n» for Zone 2

OPERATION MANUAL MODEL 8102 ACCELEROMETER

INTRINSICALLY SAFE Pressure Transducer / Transmitter AST4401

RoHS. Ready. KILOVAC LEV100 Series 900 Vdc Contactor DESCRIPTION KEY FEATURES

Intrinsically Safe or Explosionproof? Understanding the technology

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

Rod probe 11961Z. Technical Information. Conductive level limit detection Partially insulated rod probe for use in conductive liquids

INSTRUCTION MANUAL. SIL 2 Load Cell/Strain Gauge Bridge Isolating Converter DIN-Rail Power Bus and Termination Board Model D5264S D5264S

15203B 25203B 35203B Uniaxial Biaxia Triaxial

Smart Series TAS-05-11, TAS-05-12

Rosemount 752 Fieldbus Remote Indicator

Rosemount 2090P Pulp and Paper Pressure Transmitter

Indoor/outdoor resistance thermometer Model TR60

Quick Start Guide For the

Technical Data. Dimensions

INSTRUCTIONS FOR SAFE OPERATIONS LM3000 EXPLOSION PROOF LASER DISTANCE METER

IECEx Certificate of Conformity

RPS/DPS High Accuracy Resonant Pressure Sensor. GE Oil & Gas. Features:

North American Cable Glands

Transcription:

FEATURES» From the Vibro-Meter product line» Vibration monitoring over a wide temperature range, including cryogenic temperatures» Differential output» Hermetically welded» Certified for use in potentially explosive atmospheres» Frequency response: 0.5 to 6 000 Hz» Sensitivity: 10 pc /g» Temperature range: 253 (20 K) to 500 C IECEx NEPSI TIIS KGS DESCRIPTION The piezoelectric material used in the compression-mode accelerometer produces an extremely stable and reliable device. The transducer is designed for long-term monitoring and measurement of vibration over wide temperature ranges in severe environments, such as cryogenic applications and gas turbines. The is available as a transducer only which allows different twin-conductor cables mineral insulated (MI) or softline to be used depending on the temperature requirements of the application. Information contained in this document may be subject to Export Control Regulations of the European Union, USA or other countries. Each recipient of this document is responsible for ensuring that transfer or use of any information contained in this document complies with all relevant Export Control Regulations. ECN N/A. Meggitt SA / 262-002 / Version 4 / 16.10.2014 / E 1 / 5

SPECIFICATIONS General Input power requirements Signal transmission Signal processing : None : 2-pole system insulated from casing, charge output : Charge amplifier Operating At +23 C ±5 C (+73.4 F ±9 F) Sensitivity (at 120 Hz) : 10 pc /g ± 5 % Dynamic measuring range Overload capacity (spikes) Linearity Transverse sensitivity : < 5 % Resonant frequency (mounted) Frequency response 0.5 to 3 500 Hz 3 500 to 6 000 Hz : < 10 % Insulation resistance Capacitance (nominal) : 0.001 to 500 g peak : Up to 1 000 g peak : ± 1 % over dynamic measuring range : > 14 khz nominal : ± 5 % (lower cutoff frequency is determined by the electronics used) : Min. 10 8 Ω at 23 C (73 F). Min. 10 5 Ω at 500 C (932 F). : 450 pf pole to pole. 20 pf pole to ground. Environmental Temperature range Continuous operation : 253 (20 K) to +500 C ( 423 to +932 F) Short term survival : 253 (20 K) to +520 C ( 423 to +968 F) Maximum temperature error (with respect to +23 C) 253 C (20 K) : 5 % +500 C : +10 % Shock acceleration : < 2000 g peak (half sine, 1 ms duration) along sensitive axis Corrosion, humidity : INCONEL 600, stainless steel, hermetically welded Base strain sensitivity : < 7 10-4 g/µε Environmental explosive atmospheres Available in Ex approved versions for use in hazardous locations Type of protection Ex i: intrinsic safety Europe EC type examination certificate LCIE 02 ATEX 6110 X II 1 G (Zones 0, 1, 2) Ex ia IIC T6 510 C Ga North America CCSAUS certificate of compliance 1636188 Class I, Division 1, Groups A, B, C, D Ex ia T6 / AEx ia T6 International IECEx certificate of conformity* IECEx LCI 06.0008X Ex ia IIC T6 510 C Ga 2 / 5 Meggitt SA / 262-002 / Version 4 / 16.10.2014 / E

SPECIFICATIONS (continued) China NEPSI certificate of conformity* GYJ12.1448X Ex ia IIC T6 to T510 C Ga Japan TIIS certificate of conformity* TC 20544 ib IIC T1 Korea KGS certificate of conformity* 14-GA4BO-0130X Ex ia IIC T6 to T510 C Type of protection Ex na: non-sparking apparatus Europe Voluntary type examination certificate LCIE 09 ATEX 1043 X II 3G (Zone 2) Ex na IIC T6 510 C Gc International IECEx certificate of conformity* IECEx LCI 10.0017X Ex na IIC T6 510 C Gc For specific parameters of the mode of protection concerned and special conditions for safe use, please refer to the certificates that are available from Meggitt SA on demand. Physical Dimensions : See Mechanical drawings on page 4 Weight Mounting : 120 g (0.265 lb) approx. : Three M4 x 16 Allen screws and three M4 spring lock washers with a fastening torque of 4.5 N m. Electrical insulation of the mounting surface is not required. Connectors : Terminated with a rugged circular, threaded ring, 2-pole connector. Mates with a CG-505 connector (MIL-C-83723 military standard, series III K). Calibration Dynamic calibration at factory at 5 g peak and 120 Hz (+23 C). No subsequent calibration necessary. Meggitt SA / 262-002 / Version 4 / 16.10.2014 / E 3 / 5

MECHANICAL DRAWINGS Ø 20 +2 0.5 View A Direction of acceleration to provide a positive signal Ø 20 40 ± 1 6.5 ± 0.5 MARKING 9.5 ± 0.5 A + View A + 40 ± 1 6.5 ± 0.5 0.01 Mounting Ra 0.8 surface surface 9.5 ± 0.5 A Key to be within ± 5 of true position Ø 38 ± 0.5 Ø 30.175 ± 0.2 Ø 4.6 ± 0.2 Ø 38 ± 0.5 Ø 30.175 ± 0.2 Ø 4.6 ± 0.2 MARKING 15.5 ± 0.7 Note: All dimensions are in mm unless 30.5 otherwise ± 1 stated. 15.5 ± 0.7 Ø 15.7 max. 7/16-27UNS-2A 7/16-27UNS-2A Ø 15.7 max. Lock-wire hole (Ø 1) Note: All dimensions are in mm unless otherwise stated. ORDERING INFORMATION To order please specify Type Designation Ordering number Piezoelectric accelerometer 144-134-000-203 MOUNTING ACCESSORIES TA 104 Mounting adaptor See drawing 144-136-301-101 TA 105 Mounting adaptor See drawing 144-136-302-101 4 / 5 Meggitt SA / 262-002 / Version 4 / 16.10.2014 / E

Headquartered in the UK, Meggitt PLC is a global engineering group specializing in extreme environment components and smart sub-systems for aerospace, defence and energy markets. Meggitt Sensing Systems is the operating division of Meggitt specializing in sensing and monitoring systems, which has operated through its antecedents since 1927 under the names of ECET, Endevco, Ferroperm Piezoceramics, Lodge Ignition, Sensorex, Vibro-Meter and Wilcoxon Research. Today, these operations are integrated under one strategic business unit called Meggitt Sensing Systems, headquartered in Switzerland and providing complete systems, using these renowned brands, from a single supply base. The Meggitt Sensing Systems facility in Fribourg, Switzerland was formerly known as Vibro-Meter SA, but is now Meggitt SA. This site produces a wide range of vibration and dynamic pressure sensors capable of operation in extreme environments, leading-edge microwave sensors, electronics monitoring systems and innovative software for aerospace and land-based turbo-machinery. All statements, technical information, drawings, performance rates and descriptions in this document, whilst stated in good faith, are issued for the sole purpose of giving an approximate indication of the products described in them, and are not binding on Meggitt SA unless expressly agreed in writing. Before acquiring this product, you must evaluate it and determine if it is suitable for your intended application. Unless otherwise expressly agreed in writing with Meggitt SA, you assume all risks and liability associated with its use. Any recommendations and advice given without charge, whilst given in good faith, are not binding on Meggitt SA. Meggitt Sensing Systems takes no responsibility for any statements related to the product which are not contained in a current Meggitt Sensing Systems publication, nor for any statements contained in extracts, summaries, translations or any other documents not authored by Meggitt Sensing Systems. We reserve the right to alter any part of this publication without prior notice. In this publication, a dot (.) is used as the decimal separator and thousands are separated by thin spaces. Example: 12 345.678 90. Sales offices Your local agent Head office Meggitt Sensing Systems has offices in more than 30 countries. For a complete list, please visit our website. ISO 9001 FS 584089 ABCD Meggitt SA Route de Moncor 4 PO Box 1616 CH - 1701 Fribourg Switzerland Tel: +41 26 407 11 11 Fax: +41 26 407 13 01 www.meggittsensingsystems.com www.vibro-meter.com Meggitt SA / 262-002 / Version 4 / 16.10.2014 / E 5 / 5