A SINGLE GLOBAL LEGISLATION

Similar documents
ISO AIR FILTERS FOR GENERAL VENTILATION: DETERMINING FRACTIONAL EFFICIENCY

New standard in compressed air treatment, providing Energy Savings up to 99%

Effect of the Electro Breeze Air Filter on Airborne Particles in a Recirculating Air Duct

AIR PURIFIERS. Small problems quickly become BIG. Clean air solutions

USE OF DUST FILTERS DURING THE CONSTRUCTION OF TUNNEL SYSTEMS

New ISO classification systems and standards How do they work and what do they mean?

KVF - Capture Jet canopy with Supply Air and Side-Jet Technology KVF. Capture Jet Canopy with Supply Air and Side-Jet Technology

CamCleaner air purifier

Clarification Proposal Annex 1, PDA: A Global. Cleanroom and. Association. Clean Air Devices. Hasim Solmaz Lighthouse Worldwide Solutions

Rust, corrosion and leakages threaten even the best network. Only Quality Air Solutions. in optimal shape. air distribution

The ultimate microbiological safety cabinet

2010 Topas GmbH. Company Profile

Division III Process Gas Treatment Equipment

CPP condensate separator series. High-performance products. Designed for you!

Electrostatic Precipitator

CamCleaner air purifier.

INDUSTRIALS GROUP. Refrigerant Dryers. Innovative Compressed Air Treatment Solutions GDD Series

REFRIGERATED AIR DRYERS SCFM. CRPC Energy Saving Series

Spray Painting and Coating

UralActiv. manufacturer of products from polypropylene GAS WASHERS. UralActiv Ltd +7 (343)

Safety standards relevant to Refrigeration, Air-Conditioning and Heat Pump equipment

Article Energy Saving Benefits of Adiabatic Humidification in the Air Conditioning Systems of Semiconductor Cleanrooms

ACORE Filtration Co.,Ltd provides engineering,

ISO INTERNATIONAL STANDARD. Non-destructive testing Magnetic particle testing Part 2: Detection media

L a b o r a t o r y E q u i p m e n t C a t a l o g

Air Purification Systems. Clearing the Air. Air Purification Systems. Air Purification Systems

Chapter 9: The basics of air preparation

CLEAN AIR SYSTEMS DIVISION. An ISO 9001 Certified Company. Nan Technical Trading W.L.L P.O.Box Manama Kingdom of Bahrain

ISO/TS TECHNICAL SPECIFICATION. Road vehicles Air filters for passenger compartments Part 1: Test for particulate filtration

RHP & FHP Series. High Pressure Air Treatment Global Air Treatment

FUTURE AIR SOLUTIONS OIL FREE SCROLL COMPRESSORS

INTELLIGENT SOLUTIONS FOR ADIABATIC COOLING IN DATA CENTERS

Compressed Air Quality Audit ISO 8573

ecodry Figure 1 - Process Diagram ecodry B General Process Description

ISO INTERNATIONAL STANDARD

Medical electrical equipment

THE INDUSTRIAL APPROACH TO DUST MONITORING

Glenside Environmental Services Ltd

ADVANCE TECHNOLOGIES FOR ADIABATIC COOLING AND HUMIDIFICATION Nortec Humidity, Inc. Fred Valentini Direct Room Systems Regional Manager Randall

Independent Lab Comparison of Electronic Air Cleaners

Energy Saving Refrigerated Compressed Air Dryers DES Series 90 to 675 scfm (153 to 1148 nm 3 /h)

Are Your Kitchen Hood Filters Compliant?

ISO INTERNATIONAL STANDARD. Non-destructive testing Penetrant testing Part 2: Testing of penetrant materials

Residential Heat Recovery Ventilation. REHVA European Guidebook No 25

DP 300 mobile dew point instrument

International comparison of validation methods for dust concentration measurement

Compact Filter Unit Type CFU

V A C U U M A N D P R E S S U R E T E C H N O L O G Y

This document is a preview generated by EVS

AEROSOL SPECTROMETERS

OIL-INJECTED ROTARY SCREW COMPRESSORS. GA 5-11 (5,5-11 kw/7,5-15 hp)

BUSINESS PLAN CEN-CLC/TC 3 QUALITY MANAGEMENT AND CORRESPONDING GENERAL ASPECTS FOR MEDICAL DEVICES EXECUTIVE SUMMARY

OIL-INJECTED ROTARY SCREW COMPRESSORS. GA 5-11 (5,5-11 kw/7,5-15 hp)

ACTIVITIES OF THE MEASURING GROUP

CLIMACIAT AIRTOP. Air handling units. Very short delivery time Double wall with 50 mm insulation. Complete range meeting all the tertiary requirements

Tel: Fax: Website:

Membrane Dryers KMM Series

FIDAS FINE DUST MONITORING SYSTEMS

POL. INDUSTRIAL EURÓPOLIS C/Copenhague No.12 Of Las Rozas (Madrid)

Washer & Disinfector Systems

ENVIRO UNIT ENGINEERING MANUAL KES SERIES

Membrane Dryers KMM Series

PREDICTING GASEOUS AIR CLEANER PERFORMANCE IN THE FIELD

Membrane Dryer. Air inflow rate KMM Series to m 3 /min

INTRODUCTION TO DUSTS AND THEIR EXPLOSIVE PROPERTIES

First Revision No. 1-NFPA [ Chapter 2 ]

BUSINESS PLAN. CEN/TC 137 Assessment of workplace exposure to chemical and biological agents EXECUTIVE SUMMARY

The overview of standard of equipments used in asbestos removal Naroo Lee, Ph.D./Department of work environment

Oil Mist Separator Unit LGA 600 FUW

ESPAIR E AIRTM ESPA ESPAIRTM. Kitchen Exhaust Air Treatment System KET Series.

Definitions of terms and abbreviations commonly used in REHVA publications and in HVAC practice

RS-70 is suitable as a direct replacement for R-22 in low, medium and high temperatures in a great number of applications:

PRODUCT NUMBER: Rd40 Aluminium Canister AXP3

[1] Lecture 2 Particulate emission control by mechanical separation & wet gas scrubbing

Air Handling Units. T F E.

Clean Room Solutions 2013

MANUAL. Dryspell INSTALLATION OPERATION MAINTENANCE. Regenerative Type Heatless Desiccant Dryer

Combustible Dust Booklet

WFH Series. High Efficiency Filters

Desiccant Dryers DC Series (Heatless regenerated) Air flow rates 0.15 to m³/min.

This document is a preview generated by EVS

CLEARPOINT THE WINNING COMBINATION FOR CLEAN COMPRESSED AIR

Load type and process/autoclave selection

Hurricane Cyclones To Reduce Emissions of Dryer Cyclones in Glowood Pellet Plant April 2016

The Enviro-Clean Air Scrubber keeps the Atmosphere Clear and Creates Clean Air

GHS Dust Explosion Guidance. ANNEX 11 Guidance on other hazards not resulting in classification. September 2017

Healthy Climate Indoor Air Quality Solutions. Solutions that fit your unique needs

ISO INTERNATIONAL STANDARD. Fire detection and alarm systems Part 20: Aspirating smoke detectors

NEW GREEN TECHNOLOGY

VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power

ECCO - NEW ELECTROSTATIC PRECIPITATOR PILOT PLANT AT PLABUTSCH TUNNEL IN GRAZ

Refrigeration Dryers TG TI Series

Suction Accumulators. Introduction. Suction Accumulators

A Project of Cleaning Smog and Particulates by Using Smog Cleaner with Negative-Ion Generator

Sýnishorn Ventilation in hospitals - Coherent hierarchic structure and common terms and definitions for a standard related to ventilation in hospitals

RDS SERIES REFRIGERATED COMPRESSED AIR DRYERS ENERGY SAVING REFRIGERATED COMPRESSED AIR DRYERS SCFM

Frequently Asked Questions

Oil Mist Separator Unit LGA 600 FUW

August 3, Marshal Sterio Surgically Clean Air, Inc 3451 Lake Shore Blvd. W. Toronto, ON M8W 1N2. Dear Mr. Sterio:

Refrigerated Compressed Air Dryers

Transcription:

JUNE 2018 ENTRY INTO FORCE OF THE NEW UNI EN ISO 16890:2017 STANDARDS A SINGLE GLOBAL LEGISLATION

In June 2018 the new UNI EN ISO 16890:2017 standard will come into force, which will bring substantial changes in test methods and classification of filters from class G to class F, the old UNI EN 779:2012 standard, used in common ventilation systems. UNI EN 779:2012 will be permanently replaced in August 2018 The standard approved with 100% of the votes from the countries participating in the CEN and ISO technical committees will replace the American ASHRAE 52.2 standards and the European UNI EN 779:2012 standards. In ISO 16890:2017, filters will no longer be divided into Coarse (G), Medium (M) or Fine (F) efficiency classes, but will be divided into 4 classes: ISO Coarse, ISO epm 10, ISO epm 2.5 and, lastly, ISO epm 1. As can be seen, EN ISO 16890:2017 classifies filters based on atmospheric particulate, following joint studies of scientific and medical communities and the WHO (World Health Organization), which have found and confirmed the ever increasing danger for human health caused by particles less than 1 micron in the environment. The PM values can be measured locally or, in the absence of the same, data obtained from the monitoring of regional ARPAs can be used, through the control units located in the municipality in which they belong. This will allow you to install the various filtering stages according to the quality of the outdoor air (Outdoor Air Quality - OAQ). The figure below shows the human respiratory system and where it is attacked by particles of fine dust. Particulate 10 µm Upper respiratory tract Particulate 2.5 µm Lower respiratory tract Particulate 1 µm Alveoli Particulate 0.1 µm Circulatory system It can therefore be said that the studies on air pollution led to the creation of UNI EN ISO 16890:2017 with stricter tests for filter classification, thus improving indoor air quality (Indoor Air Quality - IAQ) and therefore the health of human beings.

Classification table according to UNI EN ISO 16890:2017 Group Reference particulate Class Classification Requirements Final Pressure Drop (Pa) <50% 10 µm Iso Coarse gravimetric arrestance N / d 200 10 µm Iso (50%) (55%) (60%) (65%) (70%) (75%) (80%) (85%) (90%) (95%) efficiency minimo 2,5 µm Iso (50%) (55%) (60%) (65%) (70%) (75%) (80%) (85%) (90%) (95%) efficiency Efficiency discharged filter 300 minimo 1 µm Iso (50%) (55%) (60%) (65%) (70%) (75%) (80%) (85%) (90%) (95%) efficiency Efficiency discharged filter The filters will be tested with a particular test tunnel with flow rates ranging from 900 m3/h (with 0.25 m3/s speed) to 5400 m3/h (with a speed of 1.5 m3/s). The frontal dimension of the filter that will be tested is 592x592 mm (As required by the UNI EN 15805:2010 standard). The same filter could fall into several classes, but according to the standard you can classify and then label the filter to a single class

Example of a new label for rigid pocket filters Below we provide an example of a label that will be applied (until August 2018) to a rigid pocket filter our model DFT / DIE 95 C3. Batch No: 17/18 Order No: 2018-00049 DE TR9C3 DE TR9C3 www.defil.it Dimensions (mm): 592*592*592 EFFICIENCY EN779-2012 ISO 16890 F9 epm1 80% Flow (m3/h): 4250 Dif. Pressure (Pa): 155 As can be seen, according to the UNI EN 779:2012 standards the filter is classified F9, while it is classified epm 1 80% according to UNI EN ISO 16890:2017.

Classification comparison table according to UNI EN 779:2012 and UNI EN ISO 16890:2017 Differences UNI EN 779 :2012 UNI EN ISO 16890:2017 Air flow used in the test tunnel Classes 850 m 3 /h (V= 0,24 m 3 /s) 5400 m 3 /h (V= 1,5 m 3 /s) G 1 - G 2 - G 3 - G 4 - M 5 - M 6 - F7-F8-F9 Test particle diameter 0,4 µm Efficiency Discharged efficiency (Ed) Aerosol used for the test Minimum (ME) for classes F7-F8-F9 Tested on filter media samples in class F7-F8-F9 with liquid isopropanol DEHS (Octyl sebacate) 900 m 3 /h (V= 0,25 m 3 /s) 5400 m 3 /h (V= 1,5 m 3 /s) ISO Coarse epm 10 - epm 1 10 µm (depending on class) Average (EA) between initial efficiency (Ei) and discharged efficiency (Ed) Tested on complete filter with isopropanol vapours DEHS for dust from 0.3 μm to 1 μm KCL (potassium chloride) for dust from 2.5 μm to 10 μm Dust accumulation Dust used for coarse filter tests and energy efficiency Quantity of dust emitted for testing Classes from G1 to G4 up to final Pressure Drop of 250 Pa Classes from M5 to F9 up to final Pressure Drop of 450 Pa vpm10 < 50% - Final Pressure Drop of 200 Pa PM10 50% - Final Pressure Drop of 300 Pa ASHRAE ISO fine A2/C 70 mg/m 3 140 mg/m 3 Group UNI EN 779:2012 Iso Coarse CLASSIFICATION UNI EN ISO 16890:2017 epm 10 epm 1 Coarse Medium Fine G1 G2 G3 G4 M5 M6 F7 F8 F9 40% 70% 80% 90% 50% 55% 65% 70% 80% 85% 90% 95% 95% 100% 10% 35% 50% 55% 70% 75% 80% 85% 90% 95% 5% 20% 20% 40% 60% 65% 75% 80% 85% 90%

Tunnel and test procedure The test tunnel to test the filters with the new UNI EN ISO 16890:2017 standard is similar to the tunnel used to test the filters with the old UNI EN 779:2012 standard. The tunnel consists of: A chamber where the test aerosol/dust is introduced A section where the filter to be tested is installed Final section of the tunnel The aerosol/dust introduction chamber is filtered at the inlet with an absolute polydihedral filter in class H13 according to the UN EN 1822:2010 standards. The chamber has a mixing inlet, where the aerosol/dust is introduced, and is composed of a perforated plate and a plate with a mixing deflector. An aerosol generator introduces the DEHS aerosol (from 0.1 μm to 1 μm) and the KCL aerosol (from 1 μm to 10 μm). In the chamber there is also a neutraliser and a dust dispenser, which inject the right amount of aerosol into the circuit. The section where the filter to be tested is installed consists of a transparent part, in order to observe the filter and its behaviour continuously, and of isokinetic probes, in order to suck the aerosol upstream and downstream of the filter; there are also pressure taps in order to measure the load loss, upstream and downstream of the section. The final section of the tunnel is composed of a further mixing input, in case a spectral efficiency test is also to be performed (for epm 10 >20% and <epm 1 99% classes), or a final efficiency filter epm1 65%, if an accumulation test is to be carried out. In the section there is also a hot-wire anemometer for measuring the flow rate, and in the end another absolute filter in class H13 according to EN 1822:2010 is installed in order to return clean air to the environment. Once the test is performed, the results will be collected. At this point the tested filter will be placed in a particular conditioning chamber, where it will be discharged from its electrostatic charge, by introducing into it isopropanol (IPA) vapours for 24 hours. Once the filter has been discharged, it will be left to rest for 30 minutes (to allow the isopropanol vapours to evaporate) then the test will be repeated from the beginning and the results will be collected once again at the end of the test. The results of the two tests will be compared and an average will be calculated to obtain the final filter class

Below is an example of a test result. epm 1, min. 44%, min. 59% Iso rating epm 1 48% 64% epm 10 80% Iso 55% Note: Always remember that filter classification is the test average with an electrostatic charged and discharged filter The 3 classes must always be reported in the test (even if the values do not reach the optimal data for the respective class) Minimum efficiency (ME) must always be reported for epm1 and epm2.5 classes The final value must always be rounded down to multiples of 5%