HAUBER-Elektronik. Product overview. Condition monitoring Mechanical protection in compliance with DIN ISO 10816

Similar documents
COMPACT FLAME CONTROLLER CFC 2000

DICTATOR Hold-Open Systems for Hazardous Areas

COMPACT FLAME CONTROLLER CFC 200 (Formerly 8.XX)

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Dräger Polytron 8100 EC Detection of toxic gases and vapors

Dräger Polytron 8720 IR Detection of carbon dioxide

Dräger Polytron 8100 EC Detection of toxic gases and oxygen

Dräger Polytron 8700 IR Detection of flammable gases and vapors

COMPACT FLAME CONTROLLER CFC 1000

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Dräger Polytron 8310 IR Detection of flammable gases and vapour

Operating Instructions for Limit switch Model: NBK-R NBK-RM NBK-RT NBK-RA

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Trusted worldwide since 1989 INTRINSICALLY SAFE RANGE

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Dräger Polytron 5720 IR Toxic Gas Detection

PRODUCT OVERVIEW. Light fittings, boxes & custom built control panels for explosive atmospheres

Dräger Polytron 8200 CAT Detection of flammable gases and vapors

Dräger PIR 7200 Detection of toxic gases and oxygen

Dräger Polytron 5100 EC Detection of toxic gases and vapors

INTRINSICALLY SAFE LIGHTING RANGE

AO Annunciator Module

Engineering Guideline. pac- Carriers Type Universal

Manual Power relay SR853

Dräger Polytron 5720 IR Detection of carbon dioxide

Dräger Flame 2100 Flame Detection

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Dräger Flame 2500 Flame Detection

SITRANS T temperature transmitters A broad product family for every application. sitrans

Gas cooler series TC-Standard+ X2

OPTIBAR DP 7060 Supplementary Instructions

Operating Manual MS220KA and MSR220KA

vibration switch

COMPACT FLAME CONTROLLER CFC 100

Gas cylinder scale Model GCS-1

Dräger Flame 2500 (IR3) Flame Detection

SBEx-4 BISTATE SEPARATOR 1, 2, 3 or 4 channels in rail housing (TS35, 22,5mm width)

Snifter ATEX22 VERSION. User Manual. Distributor

HOW LIMIT AND BASIC SWITCHES CAN STOP MACHINES FROM GOING BOOM. A Honeywell White Paper

FOR PERFECT THERMAL MANAGEMENT WORLDWIDE

LINETRAXX VMD420. Multi-functional voltage relay for 3(N)AC systems, frequency/overvoltage/undervoltage, phase, phase failure, asymmetry

PRODUCT SELECTOR GUIDE

DTS Light fittings for explosive atmospheres

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor

CA 134. Piezoelectric accelerometer. IECEx NEPSI TIIS KGS. » From the Vibro-Meter product line» Vibration monitoring over a wide temperature

New Sensing products of Meggitt Group. Moscow - October the 23 rd

Dräger Flame 2700 (Multi-IR) Flame Detection

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

Dual certification! Air handling units for potentially explosive atmospheres

WAGO-I/O-SYSTEM 750 Explosion Protection via Intrinsic Safety

Temperature Measurement Transmitters for field mounting

Dräger PIR 7000 Flammable Gas Detection

Company Introduction. Logtech! to aim at best of vibration & noise field

FlowJam S Ex. Bulk Flow Detection. Operating Instructions. SWR engineering Messtechnik GmbH

Manual Isolating Barrier D461R1 (Revision 01)

Flame Monitor for Multiple Burner Furnaces D-LE 603 D-UG 660

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

INERIS 01ATEX0060 (standard) TR CU (marking upon request, ordering code to be required)

Certificate of Compliance

Connection. e. g. Pt100. reference limit. yellow Output I. Composition

Dräger Flame 2350 (UV&IR) Flame Detection

LINETRAXX VME420. Multi-functional relay for overvoltage, undervoltage and frequency monitoring in AC/DC systems with external supply voltage

OPTIWAVE X500 Supplementary Instructions

Dräger Flame 2100 (UV) Flame Detection

Indoor/outdoor resistance thermometer Model TR60

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

AZN ATEX INSTALLATION AND MAINTENANCE

Dräger X-zone 5500 Area Monitoring

Engineering Guideline. pac-carriers Type SIEMENS ET-200M Fail-safe signal modules

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

Model 144H. Product Data Sheet , Rev DB February Content

Intrinsically safe acoustic emission equipment opens the door to permanent monitoring applications in the oil and gas industry

Dräger Flame 2370 (UV&IR) Flame Detection

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

Dräger QuadGard Control System

Thermostats. Innovative solutions for the toughest requirements

Manual Isolating Barrier D461 (Revision 05)

Intelligent sensing for every temperature and condition

Dräger REGARD -1 Control System

S5000 Gas Monitor. GMS5000.com

Dräger REGARD -1 Control System

Certificate of Compliance

Wind power Condition Monitoring. Condition Monitoring Systems (CMS) in wind turbines CMS. Authors: Martin Kluge Michael Danitschek

Water Leak Detector - Four Zone with open/short-circuit detection. Product overview

OPTIBAR P 1010/2010 C Supplementary instructions

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

PrimaX IR Gas Transmitter Designed for Reliable Performance in Extreme Conditions

VERSAFLOW VORTEX Supplementary instructions

Detection, Protection, Innovation

3M Oldham MX 43 Controller

Instruction Manual. Alarm Unit For Low Gas Level # Read manual before use! Observe all safety information! Keep manual for future use!

Temperature Control and Monitoring. innovations in heat tracing

Annubar Flowmeter Series

Integrated Solutions Low Voltage Systems

UV Flame Supervision System

Level gauges Series LS Level indicator, switch and transmitter for liquids

Snifter. User Manual. Distributor

technical datasheet technical datasheet

L+T GASETECHNIK. Klöpper-Waldmann GmbH & Co. K G. Alarm unit LSG4

The information contained in this document is the property of Meggitt Sensing Systems and is proprietary and/or copyright material.

Transcription:

HAUBER-Elektronik Product overview Condition monitoring Mechanical protection in compliance with DIN ISO 10816

History 01/07/1966 Foundation 01/07/1966 - Foundation of the company in the HAUBER bakery at Paulinenstr. 14 in Nürtingen, Germany. 1970 Mars Elektronik MARS Incorporated, the maker of chocolate 1971 Type 031 bars, purchases the MARS-Elektronik company name. New company name: HAUBER-Elektronik GmbH. Short-circuit signalling relay for Deutsche Bundesbahn. 1972 Type 068 The first vibration threshold value switch, 1995 which we invented at the suggestion of the Daimler-Benz company. Type VCA3 Control chart for water turbines. The Three Gorges Dam on the Yangtze River in China. 2002 LED lights Illumination of production goods. 2005 Company founder appoints Mr Tobias Bronkal as his successor Type 640 - The first vibration 2006 transmitter at HAUBER-Elektronik. The first explosion-proof vibration control. 2007 Type 663 The first vibration control to feature SIL2 approval. 2011 Certification by HAUBER-Elektronik: ISO 9001:2008. 2015 The laboratory is expanded with the addition of a new shaker system. 2017 A new HE100 vibration control is introduced.

HE100 / HE101 Series vibration control This model series of extremely reliable vibration controls comes in a high-quality stainless steel design. To offer reliable protection and monitoring of rotating machinery, we offer this vibration control in various frequency and measurement ranges. In addition to this, there are various ATEX versions available. ATEX version Zone 1 / 21 / 2 / 22 Pressure-resistant casing, Ex d Protection through housing, Ex tb II 2 G Ex d IIC T4 Gb II 2 D Ex tb IIIC T120 C Db Intrinsic safety Ex ib (HE100) II 2 G Ex ib IIC T4 Gb II 2 D Ex ib IIIC T125 C Db Standard version ATEX version HE100 Series HE101 Series Vibration velocity Analogue output Vibration velocity Temperature measurement 1-1000 Hz / 10-1000 Hz Analogue output 1-1000 Hz / 10-1000 Hz The HE100 Series vibration control is used to measure and monitor absolute bearing vibrations in machines in line with DIN ISO 10816. Features: Operating principle: two-wire system. Measurement value: effective value (rms) of the vibration velocity in mm/s, in compliance with DIN ISO 2954. Analogue current output: interference-free DC signals from 4...20 ma, proportional to the measuring range of the vibration control. The HE101 Series vibration control is used to measure and monitor absolute bearing vibrations and bearing temperatures in machines in line with DIN ISO 10816. Features Measurement value: effective value (rms) of the vibration velocity in mm/s, in compliance with DIN ISO 2954. Measurement value: temperature in C. Two analogue current outputs: interference-free DC signals from 4...20 ma, proportional to the measuring range of the vibration and temperature control.

663 Series vibration control This compact vibration control meets all SIL2 and SIL3 safety and integrity requirements and is the ideal electronic monitoring system to provide high levels of mechanical safety. The HAUBER-Elektronik 663 Series came onto the market as one of the first SIL2-capable vibration controls and is now in use in thousands of applications. ATEX version Zone 1 / 21 II 2 G Ex d IIC T4 Gb II 2 D Ex tb IIIC T120 C Db Zone 2 / 22 II 3 G Ex d na IIC T4 Gc II 3 D Ex tc IIIC T120 C Dc Standard version ATEX version 663 Series 663 Window Series Vibration velocity Analogue and switching output 1-1000 Hz / 10-1000 Hz Vibration acceleration Analogue and switching output 1-1000 Hz / 10-1000 Hz The Series 663 vibration control is used to measure and monitor absolute bearing vibrations in machines in line with DIN ISO 10816. The Type 663-Window vibration control is used to measure and monitor vibration acceleration on machines. Features Measurement value: effective value (rms) of the vibration velocity in mm/s. Two limit values and associated delay times are separately adjustable. Each of the two relay outputs gives a signal if the corresponding set limit values are exceeded. This can be used to generate a preliminary and a main alarm. Analogue current output: interference-free DC signals from 4...20 ma, proportional to the measuring range of the vibration control. Features Measurement value: vibration acceleration (g, peak). Two limit values and associated delay times are separately adjustable. Both relay switching outputs give a signal if the set window range is exceeded or undershot. This can be used to generate an alarm. Analogue current output: Interference-free DC signal from 4...20 ma, proportional to the measuring range of the vibration control.

650 / 652 Series electronic evaluation device In addition to its vibration controls, HAUBER-Elektronik also supplies various electronic evaluation devices (650 /652 Series). The analogue signals of our vibration controls are laid down here and are combined to create stand-alone machine protection systems. After the limit value has been exceeded and the fully adjustable time limit has expired the respective relay drops out. In addition to this, the two input signals are monitored for cable breaks and the status is issued via an OK relay. This series with its easy-to-read display is the ideal complement to our vibration monitoring systems. 650 Series Suitable for HE101 Pre- and main alarm Measurement channels 1 Display The Series 650 electronic evaluation device is used to detect and monitor the output currents (4...20 ma) of the Type HE101 vibration control. The electronic evaluation device is contained in a 20-pole DIN rail housing. This can be mounted using either a top hat rail or directly on the wall. 652 Series Suitable for HE100 Pre- and main alarm Measurement channels 2 Display The 652 Series electronic evaluation device is used to detect and monitor the output current (4...20 ma) of one or two Type HE100 vibration control (s). The electronic evaluation device is contained in a 20-pole DIN rail housing. This can be mounted using either a top hat rail or directly on the wall.

Electronic evaluation device 656 Series Suitable for HE100 Measurement channels 1 Main alarm The 656 Series electronic evaluation device is designed for top hat rail mounting. The limit value is monitored together with a fully adjustable delay. This series also has OK monitoring. HE100 Series vibration controls can be connected. It has wide-ranging applications: all rotating machines which require economical limit value monitoring. 400 Series Suitable for HE100 Measurement channels 1 Portable measuring device A portable measuring device belongs in the portfolio of a wellrounded vibration measuring technology system. The 400 Series measuring device from HAUBER-Elektronik represents the effective value of the vibration velocity. HE100 Series vibration controls can be connected. This means that overall vibration from 1 Hz or 10 Hz up to 1000 Hz can be measured. The battery-operated device is very simple to use and gives the user a quick overview of the status of his machines which can be evaluated by using guidelines.

Product accessories When it comes to the professional and industry-compatible installation of vibration controls and electronic evaluation devices, you will find everything you need for your particular application at HAUBER-Elektronik: cables, plug connectors, installation adapters and magnets for mobile use. Sensor cable High-quality shielded sensor cable for safe use in industrial environments. Connector High-quality plug connection for safe use in industrial environments. Available in a variety of versions to suit particular applications. Metallic protective hose Perfect protection for the sensor cable for the harshest industrial environments. Metal protective hose with adaptation Perfect protection for the sensor cable including sensor adaptation for the harshest industrial environments. Seamless protection of the sensor cable. This metal protector is suitable for HE100 & HE101 sensors.

Product accessories Mounting accessories Metric threads and inch threads are available depending on requirements and customer preferences. For mobile measurements, we offer a magnet with a high pulling capacity. In addition to this, an EMC adapter for insulating the sensor housing from the machine potential is also available. Rubber nozzle The rubber nozzle protects the sensor as well as the cable connection against mechanical effects and prevents the ingress of moisture. The rubber nozzle is recommended particularly when the sensors are used outdoors. Terminal box High-quality terminal boxes are a reliable means of transmitting signals to higher-level controllers. The focus in this case is on flexibility and the desired customer requirements. ATEX isolating amplifier The feed/isolating amplifier is used to safely operate the HE100 vibration control with the Ex i type of protection. It transmits signals from the potentially explosive area to the safe area.

Fields of application Fans Fans are used successfully in almost all sectors of industry. Status monitoring helps to prevent faults such as imbalances or misalignments, identify wear processes early and make optimal use of the lifespan of components. Centrifuges These systems are an integral part of the processes of many sectors of industry. Both status monitoring and personal protection play a central part in this. It is here that vibration monitoring systems with SIL/PL-d authorisations are particularly applicable. Vibrating troughs Conveyor technology is the focus here. Vibration measurement technology helps to detect both increased and insufficient levels of vibration. Special vibration monitoring systems are available for this, such as Type 663-WINDOW.

Fields of application Turbines Turbines and generators have their application in the chemical, oil & gas or paper industries. Measurement of housing vibration is a typical process and a sound measure in status monitoring that is indispensable for the system operator. Mills Mills are an important element in the cement industry, for instance. System components that are vital to production can be permanently monitored for vibration. This increases process safety, product quality and plant availability in a cement works. Pumps Pumps are indispensable for conveying liquid or solid media, making them a permanent feature of any industry. Vibration monitoring is the means of helping the system operator to achieve functional status monitoring.

Notes

HAUBER-Elektronik Contact HAUBER-Elektronik GmbH Fabrikstraße 6 72622 Nürtingen Germany Tel.: +49 7022 21750 0 Fax: +49 7022 21750 50 info@hauber-elektronik.de www.hauber-elektronik.de