CIATCOOLER LJA. Chilled water production units USE. Attractive design, Compact and quiet

Similar documents
HYDROCIAT LW R407C. Water cooled chillers USE RANGE

AGEO CALEO. Water-to-water high temperature heat pumps USE RANGE DESCRIPTION. Designed to replace a conventional boiler and produce domestic hot water

AQUACIAT. Water chillers. Free cooling modules for AQUACIAT2 700V to 1100V AQUACIAT POWER 1200V to 1800V USE RANGE FREE COOLING

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

ECOCIAT. Domestic hot water heat recovery unit. Use. Range

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CONDENCIAT CD. Condensing units. Quiet operation Low speed fans All year round operation USE. Cooling capacity : 25 to 165 kw.

GeoCIAT Modular. Components. Heat pump Heating only, Glycol/water mix/water. Refrigerant and hydraulic module diagram. HomeConnect control.

EXPAIR. Use. Precision air handling cabinets. Reducted footprint Dual-wall construction

MAGISTER. Compact and attractive design Energy savings with EC motor and self-regulating control. Easy to install. Use. Chilled water operation

Compact and silent Scroll compressors All-season operation

DYNACIAT POWER. High energy efficiency Compact and quiet

Split inverter air-to-water heat pump CERTIFIED BY CERTITA. option 30/35-40/45

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

AQUACIAT. Inverter Heat pump USE RANGE GRAND INVERTER

The refrigerant circuit was studied in detail. Each step is verified, ensuring that each unit is perfectly leak-tight.

VEXTRA. acoustic comfort Saves up to. 40% floor space. Use. Range. Description. Drycoolers. Slim design and. Capacity up to kw.

High temperature air-to-water heat pumps

CLIMACIAT AIR COMPACT

FLOWAY. Floway Range. The dual-flow air handling unit with heat recovery guaranteeing an Economical and Durable solution. use.

CHG AIR COOLED WATER CHILLER WITH CONDENSATION BY HELICOIDAL AIR 8 to 17 kw

AQUACIAT. Water chillers. Free cooling modules for AQUACIAT2 700V to 1100V AQUACIAT POWER 1200V to 1800V USE RANGE FREE COOLING

Chiller units and air-water heat pumps RANGE OPERATING LIMITS

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

OPERA MORE. Use. Range. Drycoolers Air-cooled condensers. for LESS. Capacity: up to 1100 kw. Water misting. Free cooling

DRYPACK. Protecting installations Energy optimisation. Operating principle. Description. Biogas dehumidification system. Improved profitability.

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

Roof top SPACE RPC 450Z R407C M011

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

AIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS

Centrifugal air heaters hot water or electrical supply

PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER 9 to 18 KW

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

AQH 40 to 130. u Air-to-Water Reverse Cycle Heat Pumps. 40 to 131 kw. 45 to 141 kw. Engineering Data Manual

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

LSK LSK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

Roof top SPACE RPC 315Z R407C MA00

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

Precision air handling cabinets Ciatronic MICRO/EXPAIR

DYNACIAT LG. Use. Range. Water chillers Heat pump. DYNACIAT LGN series. DYNACIAT LG series. Hydraulic module

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

Vertical self-contained air conditioner

Большая библиотека технической документации каталоги, инструкции, сервисные мануалы, схемы.

EKS/HE. MultiScroll Air-cooled liquid chillers High efficiency. Solution B - Base I - Integrata

HT V2 HT Split

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

LDK LDK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

AQUACIAT LD ILD. Use. Range. Water chillers Heat pump. AQUACIAT LD series. AQUACIAT ILD series. Heat recovery. Cooling only. Cooling and heating

DYNACIAT ILG. Use. Description. Heat pumps

30RB/RQ 039S-160S Refrigerant HFC-410A Nominal cooling capacity kw Nominal heating capacity kw

Water chillers water/water type SIGMA Technical information manual

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES

Precision air-handling cabinets. CIATRONIC System Ultimate precision air-conditioning NA C

LZT High efficiency air to water heat pumps with E.V.I. compressors

Aquaciat Free cooling

EASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB

condenciat cl Condensing units Outdoor condensing unit Variable speed propeller fan Use Description for direct expansion applications

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

High temperature air-to-water heat pumps

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

LZA High efficiency air to water heat pumps with HP compressor

CZT CZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSIONS ACCESSORIES

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

WSK WSK. Water to water chillers and heat pumps VERSIONS ACCESSORIES

Galletti Water chillers and heat pumps catalogue

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

RAS Kp AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 LIQUID CHILLERS - AIR COOLED AIR

HOT AIR GENERATOR WITH GAS BURNER NA11.45 A GGS. Installation Operation Commissioning Maintenance

LSA LSA A + Air cooled water chillers with axial fans VERSIONS ACCESSORIES

30RB/RQ 039S-160S. Air-Cooled Liquid Chiller Reversible Air-To-Water Heat Pump Nominal cooling capacity: kw Nominal heating capacity: kw

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz

Split-system cooling units and heat pumps SERIES. Outdoor unit. Indoor unit OPERATING LIMITS. Inlet air conditions Cooling Heating.

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS

V3000 KNX. KNX PID control system on water GENERAL DESCRIPTION

30GK. Air-Cooled Liquid Chillers. Nominal cooling capacity kw

Aquaflair TRAC-TRAF-TRAH

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

Refrigerant R407C CW-AR. 2.4 to 3.1kW. Water Source Heat Pumps - Vertical Mounting Version Models 07 to to 2.7kW

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED

AQUACIAT2 HYBRID. Natural GAS condensation boiler Self-adjusting electronic control. Use. Range. Heat pumps and gas boilers

Air Cooled Chillers & Heat Pumps WinPACK HE-A

30RH B Nominal cooling capacity kw Nominal heating capacity kw

30RBY/RQY Ductable Air-Cooled Liquid Chillers/ Ductable Air-to-Water Heat Pumps PRO-DIALOG +

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

All series is using Hitachi scroll compressor, low vibration and high efficiency. Internal thermostat embedded compressors, and it can react quickly.

CLIMACIAT. air HanDLIng UnIT: CLIMaCIaT. Air handling unit

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw

WZH Ground source heat pumps

EREBA ACCESS. Easy and fast installation Hydronic module available Compact, reliable and efficient USE RANGE CONFORMITY

Kälte Klima. Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW. Compressors Scroll SCAEY DE 88 04/11 12/10

WDH WDH. Ground source heat pumps OTHER VERSIONS ACCESSORIES


Aquair BCP. Pool air handling units. Electronic Control Optimized energy consumption DESCRIPTION PRINCIPLE SCHEMES RANGE OPERATING LIMITS

HYDRONIC RESIDENTIAL

Transcription:

Attractive design, Compact and quiet Many customisable configurations possible For indoor installation New reliable technologies Version with Plug and Cool hydraulic module Cooling capacity: 23 to 140 kw Cooling only Heat recovery ENVIRONMENTALLY HFC R407C PROTECTION DE FRIENDLY L'ENVIRONNEMENT USE LJA CIATCOOLERS The LJA CIATCOOLER packaged chilled water production units with air-cooled condenser offer a solution to all the cooling applications encountered in collective housing or service buildings, in industrial processes and on industrial premises. Several customisable configuration possibilities (fan power, supply air direction and hydraulic connections) provide workarounds to layout issues in mechanical rooms. Flexible connecting sleeves at air intake and discharge, flexible connections and antivibration mounts provided as optional make the units even easier to integrate into installations. The units can be connected to all types of aeraulic networks and sound traps (not supplied) thanks to wide pressure ranges available on air. The units are fully encased to give excellent acoustic results. LJAH CIATCOOLERS With their built-in hydraulic modules, the LJAH CIATCOOLER chilled water production units provide ideal solutions to meet the criteria of simplicity and quick installation. The module integrates the complete hydraulic unit for traditional installations (buffer tanks, expansion vessels, circulating pumps, etc.). 1

DESCRIPTION Units in compliance with standards EN 60-204/EN 378-2 and with the following directives: - Machines 98/37 CEE, - CEM 89/336 CEE modified 92/31 CEE - 93/68 CEE, - DESP 97/23 CEE -> category 2. The LJA - LJAH CIATCOOLERS make up a new generation of compact monobloc liquid coolers that benefit from the latest technological developments. Customisable product. Structure - Casing made up of painted aluminium profiles with lacquered galvanized double-wall metal sheet (RAL 7024) with thermal insulation. SCROLL hermetic compressor - Built-in motor cooled by suction gases. - Internal motor protection by winding sensor. - Fitted on antivibration mounts. Brazed plates evaporator(s) - End and internal plates made up of AISI 316 stainless steel, with high performance level optimised profile. - Incorporated thermal insulation. Air-cooled condenser - Copper tube coil/aluminium fins crimped mechanically. - Pulley and belt driven centrifugal fan(s). - Waterproof motor, IP 55, class F. - Vertical or horizontal front or horizontal rear discharge. Control and safety devices - High and low pressure safety devices. - Chilled water and anti-freeze evaporator sensors. - Mounted evaporator water flow controller. - Thermostatic expansion valve. - Additional dry-contacts board adapter, - Adapter for remote control, - Analogic and multilingual LCD display with LED indicators. Functions: - Regulation of the water temperature (on evaporator outlet or return) according to the outside temperature, - Display of operating data by:. Multilingual messages displayed in clear text. Direct reading of temperatures and pressures. - Complete management of the compressors with start-up sequence, metering and balancing of working hours, - Self-adapting and anticipating functions with adjustment of the regulation depending upon the parameters drift, - Staged capacity-reduction device operating in series on the multi-compressors, depending upon the cooling or heating requirements measured on water temperatures, - Control of the internal working parameters, - Management of a second setpoint, - Direct display of water temperatures and pressures, - Diagnosis of the operating and fault status: HP/LP, water flow, compressor motor(s), and antifreezing, - Anti short-cycle protection, - Remote control and remote monitoring. Control panel Fully wired, the electrical panel contains all of the electrical components and the electronic CPU board, providing full control and allowing the machine to be monitored, the water setpoints to be adjusted, or acts as the interface to an external control system. It is composed of: - Power and control circuits, - Wire numbering, - Master safety switch located on the front panel, with a handle. - Control circuit transformer (350 to 600), - Circuit breakers to protect the power and control circuits, - Contactors and protection for compressor and fan motors, - General earth connection, - Electronic control module with CONNECT microprocessor, - Remote of alarms or signals on voltage-free terminals. Electronic control module CIAT microprocessor electronic control module and CPU, with central control system and access to the internal components status. Composition: - On, Off, Reset or Remote Control, - Operating mode selector - COOLING or HEATING, - Outputs: RS485 output for the GTC link (ModBus-JBus), H The basic design of the LJAH CIATCOOLER series is identical to that of the series. These derivative units integrate the complete hydraulic assembly of a traditional installation: - 1 black metal sheet buffer tank with thermal insulation. - 1 single-cell centrifugal hydraulic pump with pressure gauges (single pump or double pump). - 1 expansion vessel. - 1 automatic air vent. - 1 safety valve. - 1 filling orifice with valve and check valve. - 1 drain orifice with valve. - Contactor(s) and protection(s) for hydraulic pump(s). - 1 x 600 µm water filter. - 1 adjusting valve. - This hydraulic module can be supplied separately (see MHJ product). 2

OPTIONS Antivibration equipment - Hydraulic flexible connections kits. - Flexible air intake sleeves. - Flexible air discharge sleeves. Condenser treatment - Fins with a Polyurethane coating. - BLYGOLD POLLUAL treatment. Desuperheaters - The desuperheating option allows the recovery of calories by desuperheating the pressurised gas. Year-round operation - Down to an outside temperature of -15 C. Air filters on air intake - The kit is supplied with a register providing access to the filters. Remote control kit This box, which is delivered separately, can be used for remote control of the unit: - Functions similar to those of the control module. - The link between the remote control board and the electronic module is 2 wires only (1000 metres max.). Relay board kit for free potential contacts - This board, which is supplied separately, can be used to display faults remotely as well as the capacity control operating status. - The link between the relay board and the electronic module is made by 2 wires only (1000 metres max.). Frost protection ensured by electrical heating elements. TECHNICAL CHARACTERISTICS - LJAH 100 150 200 250 300 350 400 450 500 600 Cooling capacity (1) kw 23.7 35.7 45.1 58.8 69.8 79.6 93.0 105.7 113.3 140.8 Absorbed power (2) kw 8.5 13.1 18.2 23.1 27.5 32.0 36.1 40.4 46.6 54.4 Type / Rotation speed r.p.m. Sealed SCROLL / 2900 Compressor(s) Number 1 2 3 4 R407C (GWP = 1520) refrigerant charge kg 4.3 6.5 8.4 10.2 12 6 + 8 14 + 5 13 + 6.5 14 + 9 12 + 12 Capacity control % 100-0 100-50-0 100-40-0 100-50-0 100-70- 30-0 100-63- 37-0 100-66- 33-0 100-70- 40-20-0 100-75- 50-25-0 Min water content of a LJA plant l 112 181 110 112 174 121 174 167 106 164 Type Brazed plates Number 1 2 Evaporator(s) Water content 1.9 2.85 3.39 5.65 5.65 7.5 7.95 9.2 9.7 11.4 Hydraulic connections G1 1/4 G2 G2 1/2 Maximum pressure on water side bar LJA = 10 bars / LJAH = 4 bars Minimum water flow mini m 3 /h 3.4 4 5 7 7 9 11 12 12 15 maxi m 3 /h 7.8 10 11.5 17 17 22 26 27 29 34 Discharge variant 1/2/3 1 = Vertical / 2 = Horizontal front / 3 = Horizontal rear Air condenser Fan type Centrifugal - pulley and belt drive Hydraulic module* Airflow m 3 /h 8500 12000 14500 16000 18000 22000 24000 27000 31000 35000 Buffer capacity litres 350 Expansion vessel litres 35 Pre-inflating pressure bar 1.5 (1) Cooling power for chilled water operation at 12 C/7 C and a condenser air inlet temperature of 35 C. * LJAH version only. ELECTRICAL CHARACTERISTICS (2) Power input for compressors only (add selected pump and fan power). = Power input, compressors only (add fan and pump power based on configuration) Customisable product - LJAH 100 150 200 250 300 350 400 450 500 600 Rated max current A 20.44 29.74 40.54 49.84 59.14 69.83 79.13 88.43 99.23 117.83 Starting current A 120 175 145 200 210 240 249 258 269 292 Electrical power supply V 3 ph. 400V - 50Hz - + Neutral + Earth 3 ph. 400V + Earth FAN MOTORS (1) kw 2,2 3 4 5,5 7,5 9 11 15 Max. rated current A 5,2 7,1 9,2 12 16 18,6 22 29,3 (1) Motor selection in accordance with the overall static pressure. PUMPS Nr 40 41 42 43 117 118 119 217 218 219 Power kw 0.75 1.1 1.5 1.85 2.2 4.0 7.5 2.2 4.0 7.5 Max nominal current 400 V 1.85 2.67 3.9 4.61 4.5 7.8 13.8 4.5 7.8 13.8 WARNING: Total current intensity of the machine: the sum of the maximum rated currents indicated in the above tables (max rated current + fan motor + pump if LJAH) * 230 V - 3 ph - 50 Hz: Voltage in force in France. 3

AERAULIC CHARACTERISTICS Fan motor selection LJA - LJAH 100 150 200 250 300 350 400 450 500 600 Pressure available for ducts in mm Water Column 0 5 10 15 20 25 30 35 40 Airflow m 3 /h 8500 12000 14500 16000 18000 22000 24000 27000 31000 35000 Motor capacity kw 2.2 4 4 5.5 7.5 5.5 5.5 9 5.5 9 Rotation speed rpm 398 511 515 568 638 715 798 928 603 766 Motor capacity kw 2.2 4 4 5.5 7.5 5.5 5.5 9 5.5 9 Rotation speed rpm 449 543 543 602 675 753 817 970 645 777 Motor capacity kw 2.2 4 4 5.5 7.5 5.5 7.5 9 7.5 9 Rotation speed rpm 515 604 570 641 682 801 870 1015 638 829 Motor capacity kw 2.2 4 4 5.5 7.5 5.5 7.5 9 7.5 11 Rotation speed rpm 575 673 604 675 722 844 928 1044 737 860 Motor capacity kw 2.2 4 4 5.5 7.5 5.5 7.5 11 7.5 11 Rotation speed rpm 606 712 636 715 765 894 954 1087 774 902 Motor capacity kw 2.2 4 4 5.5 7.5 7.5 7.5 11 7.5 15 Rotation speed rpm 679 751 712 750 808 928 1012 1127 812 960 Motor capacity kw 2.2 4 4 5.5 7.5 7.5 7.5 11 9 15 Rotation speed rpm 715 792 751 801 848 971 1026 1165 870 986 Motor capacity kw 2.2 4 4 5.5 7.5 7.5 9 15 9 - Rotation speed rpm 753 839 755 844 967 1036 1088 1171 880 - Motor capacity kw 2.2 4 4 5.5 7.5 7.5 9 15 11 - Rotation speed rpm 798 891 798 893 906 1062 1122 1225 932 - Filter head loss* mm WC 5 6 7 * Pressure drop if filter equipment is used. This value must be added to the calculation of the overall available static pressure when selecting the motor. 6

DIMENSIONS LJA CIATCOOLER 1 or 2 compressors, 1 refrigerating circuit Handling support to be removed during installation Condenser coil intake Vertical discharge Front discharge a: chilled water inlet b: chilled water outlet c: hot water inlet (desuperheater option) d: hot water outlet (desuperheater option) e: electricity supply hatch Rear discharge A: Maintenance area LJA A B C Male connectors Mass in kg a b c d empty in operation 100 581 591 1630 305,5 1153 G1" 1/4 G1" 1/4 G1" 1/4 G1" 1/4 150 610 620 200 771 785 250 2180 518 1703 G2" G2" G1" 1/4 G1" 1/4 832 846 300 859 873 10

DIMENSIONS LJA CIATCOOLER 3 or 4 compressors, 2 refrigerating circuits Handling support to be removed during installation Condenser coil intake Vertical discharge Front discharge a: chilled water inlet b: chilled water outlet c: hot water inlet (desuperheater option) d: hot water outlet (desuperheater option) e: electricity supply hatch Rear discharge A: Maintenance area LJA a b c d e f g h j Male connectors Mass in kg a b c d empty in operation 350 1165 1179 400 2830 1333 408 352,5 475 380 243 408 2353 G2" 1/2 G2" 1/2 G2" G2" 1220 1234 450 1261 1275 500 1462 1476 3460 1390 482 570 561 454 300 482 2983 G2" 1/2 G2" 1/2 G2" G2" 600 1517 1531 11

DIMENSIONS LJAH CIATCOOLER 1 or 2 compressors, 1 refrigeration circuit Handling support to be removed during installation Condenser coil intake Vertical discharge Front discharge a: chilled water inlet b: chilled water outlet c: hot water inlet (desuperheater option) d: hot water outlet (desuperheater option) e: electricity supply hatch Rear discharge A: Maintenance area LJAH A B C D Male connectors Mass in kg a b c d empty in operation 100 896 1254 2630 1397 300,5 1153 G1" 1/4 G1" 1/4 G1" 1/4 G1" 1/4 150 925 1283 200 1122 1482 250 3180 1397 518,5 1703 G2" G2" G1" 1/4 G1" 1/4 1153 1513 300 1180 1540 12

DIMENSIONS LJAH CIATCOOLER 3 or 4 compressors, 2 refrigerating circuits Handling support to be removed during installation Condenser coil intake Vertical discharge Front discharge a: chilled water inlet b: chilled water outlet c: hot water inlet (desuperheater option) d: hot water outlet (desuperheater option) e: electricity supply hatch Rear discharge A: Maintenance area LJAH A B C D E F G H J Male connectors Mass in kg a b c d empty in operation 350 1490 1854 400 3830 1333 408 352,5 475 380 243 408 2353 G2" 1/2 G2" 1/2 G2" G2" 1560 1924 450 1617 1981 500 1785 2159 4460 1390 482 570 561 454 300 482 2983 G2" 1/2 G2" 1/2 G2" G2" 600 1850 2214 13

NOISE LEVELS Conditions in instructions - Radiated noise - Suction and discharge ducts Models SOUND POWER spectrum (db) Overall level Lw 63 Hz 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz db (A) 100 73 75 73 66 60 57 55 69 150 80 78 74 62 63 63 62 71 200 78 79 73 64 64 62 58 71 250 82 80 71 65 65 65 63 72 300 84 83 73 67 68 67 66 75 350 84 82 74 65 66 65 64 73 400 85 83 75 66 68 67 66 75 450 88 85 77 69 70 69 69 77 500 87 86 77 71 69 69 67 77 600 91 90 81 75 73 72 71 81 Sound power levels given for a nominal air flow with 10 mmwc of available pressure Conditions in instructions - Radiated noise - Suction and discharge ducts Models SOUND PRESSURE spectrum (db) Overall level Lw 63 Hz 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz db (A) 100 51 53 51 44 38 35 33 47 150 58 56 52 40 41 41 40 49 200 56 57 51 42 42 40 36 49 250 60 58 49 43 43 43 41 50 300 62 61 51 45 46 45 44 53 350 62 60 52 43 44 43 42 51 400 63 61 53 44 46 45 44 53 450 66 63 55 47 48 47 47 55 500 65 64 55 49 47 47 45 55 600 69 68 59 53 51 50 49 59 Sound power levels given for a nominal air flow with 10 mmwc of available pressure LJA LJAH 5 metres Air duct Noise radiated in open area Sound level on SUCTION: factor in when calculating the mufflers Models SOUND POWER spectrum (db) Overall level Lw 63 Hz 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz db (A) 100 78 75 73 73 75 74 70 80 150 82 79 77 77 79 78 74 84 200 83 80 78 78 80 79 75 85 250 85 82 80 80 82 81 77 87 300 88 85 83 83 85 84 80 90 350 85 81 80 79 82 79 75 86 400 86 82 81 80 83 80 76 87 450 89 85 84 83 86 83 79 90 500 89 84 82 83 84 82 77 88 600 93 88 86 87 88 86 81 92 Sound power levels given for a nominal air flow with 10 mmwc of available pressure Sound level on DISCHARGE: factor in when calculating the mufflers Models SOUND POWER spectrum (db) Overall level Lw 63 Hz 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz db (A) 100 83 87 82 84 83 82 77 88 150 87 91 86 88 87 86 81 92 200 88 92 87 89 88 87 82 93 250 90 94 89 91 90 89 84 95 300 93 97 92 94 93 92 87 98 350 90 89 86 88 87 85 81 92 400 91 90 87 89 88 86 82 93 450 94 93 90 92 91 89 85 96 500 91 93 90 92 90 89 84 95 600 95 97 94 96 94 93 88 99 Sound power levels given for a nominal air flow with 10 mmwc of available pressure 14

Installation ASSEMBLY RECOMMENDATIONS - LJA-LJAH CIATCOOLERS are monoblock units for indoor application, designed for installation in technical premises. - It is necessary to have an access area of 1.5 m wide all round the units for servicing and maintenance operations. - The air inlet to the coil and the fan discharge outlet must not be obstructed. In the case of connections via ductwork, study the system (slopes, pressure drops, velocities, etc.). A poorly designed system (excessive high speeds, poor rigidity, etc.) can result in high sound levels. - The LJA / LJAH CIATCOOLERS outlets must be ducted. The ductwork must ensure the protection of persons close to the fan. - Study the unit layout carefully, and select a location that is compatible with the requirements concerning the environment (sound levels, position of the technical premises in relation to the other rooms, etc.). Electrical connections - All the necessary instructions for electrical connections are set out in the electrical diagram supplied with the unit (compulsory compliance at any time). - These connections must be made in accordance with good engineering practice and in compliance with the standards in force. - It is essential to fit the main electricial supply cables with an isolating switch or a motor circuit breaker (to be supplied and fitted by the installer). Hydraulic connections (LJA CIATCOOLER series ) - The hydraulic connections must be made in accordance with good engineering practice - It is especially important to include the accessories essential for all hydraulic circuits: - Filter, - Expansion vessel, - Drain cocks at low points, - shut off valves, - Air vents at high points, etc. - Make sure that the water content of the installation is sufficient, - Include a buffering tank if necessary. Commissioning - Comply with our assembly and maintenance manuals. Maintenance - Comply with the operating and maintenance guide. - Take out a maintenance contract. 15

AUTOMATIC CONTROL SYSTEM CONNECT USER-FRIENDLY INTERFACE CONSOLE - Multilanguage LCD (2 lines of 20 characters each) - Pressure and temperature readings - Pump management - Communication Available voltage-free contact inputs and outputs: Inputs: Outputs: - Automatic operation control - Selection of setpoints 1/2 - Heating/Cooling mode selection - Compressor load shedding - General fault display - Pump control. RS-485 OUTPUT AS STANDARD MODBUS-JBUS open Protocol (standard) LONWORKS Protocol (option) RELAY BOARD (OPTION) Available outputs: - Water flow fault - Frost protection fault - Pump fault - Fan fault - Low and high pressure fault - Compressor safety fault - Discharge temperature fault - Compressor operation fault REMOTE-CONTROL UNIT (OPTION) Operation and design same as display console MULTICONNECT MULTI-UNIT MANAGEMENT (OPTION) Main functions available: - Management of up to 8 units on a single water loop - Management in cooling mode (water chiller) or heating mode (heat pump) - Management of chilled-water or hot-water pumps - Centralised management of a backup unit - Unit load shedding - System time programming - Energy storage mode management - Fault management on each unit - Unit running time balancing - Integrated Modbus BMS link for obtaining information on unit operation and faults This document is non-contractual.as part of its policy of continual product improvement, CIAT reserves the right to make any technical modification it feels appropriate without prior notification. Head office Avenue Jean Falconnier - B.P. 14 01350 - Culoz - France Tel.: +33 (0)4 79 42 42 42 - Fax: +33 (0)4 79 42 42 10 info@ciat.fr - www.ciat.com CIAT Service Tel.: +33 (0)4 79 42 42 90 - Fax: +33 (0)4 79 42 42 13 Compagnie Industrielle d Applications Thermiques - S.A. with a registered capital of 26 728 480 - R.C.S. Bourg-en-Bresse B 545 620 114 16