CONDANSATE TRANSFER PUMP

Similar documents
STEAM EQUIPMENT 4

LIQUID ELIMINATORS/ FLOAT TYPE LIQUID DRAINERS

MIG-FLEX EXTENSIBLE, FLEXIBLE METAL HOSES

SOLAR SYSTEM. We follow the sun.

PRESSURE MOTIVE PUMP (PMP) APPLICATIONS

Pamphlet U2404. Mechanical Pump & Pump/ Trap. GP Series GT Series

MFP14 Automatic pumps for condensate and other industrial fluids

MFP14 Automatic pumps. for condensate and other industrial fluids

STEAM TRAPS

Pamphlet A2404. Mechanical Pump & Pump/ Trap. GP Series GT Series

Pamphlet M2404. Mechanical Pump & Pump/ Trap. GP Series GT Series

E.C.A Air conditioners create a perfect silence environment with its outstanding performance

EVAC Commercial Marine Equipment TOILET TECHNICAL DATA EVAC 90, SQUATTING TOILET. To main vacuum line, connection Ø50.

Series 1140 and 1141 Temperature Regulators

System Solutions. Efficient energy use, effective flash steam utilisation, and tailor-made customer solutions CHEMICAL THE STEAM SPECIALIST.

PRODUCTS. Expansion Joints Fire Fighting. Flexible Metal Hoses. Equipments. Insulation Solutions. Steam. Valves. Level Control.

STEAM VALVE SUPPLY & SYSTEM DESIGN

SHOWER PUMPS. Installation Manual. 1.5 bar and 2.0 bar

Spray Flow II cc/liter Atmospheric Deaerator. industrialsteam.com

Spray Flow II cc/liter Atmospheric Deaerator. industrialsteam.com

Models AP-10, AP-20 and AP-30

205 Control Installation and Maintenance Instructions

Installation manual W365H, W375H, W3105H, W3130H, W3180H, W3240H, W3300H Exacta & Clarus Control

Mini Pump Trap. Features: n Low maintenance - No leaking seals, impeller or motor problems reducing maintenance and downtime.

Ball Float Controlled. Thermo Dynamic(TD) Trap Safety Valve Condensate Pump Flash Vessel Moisture Separators Deaerator Head Steam Injector Sight Glass

Air Cleaning Equipment, Inc. 303 N. Main St. Broadway, NC iers.com

C. B. Trading Corporation

VENTS. Main Steam Vents. How to Select Steam Vents. For Steam Vent selection information, please refer to Selection Guidelines on page 133.

IGH FX / IGH FX EC. Heat Recovery Ventilation Unit

PRODUCT CATALOG.

Steam Ancillary Equipment. Primary Steam System, Water Treatment and Auxiliary Steam System Equipment

YARWAY NON-REPAIRABLE DRIP AND TRACER STEAM TRAPS SERIES PB, 29, 129Y AND 29S

STEAM TRAPS FOREST PRODUCTS LIBRARY FOREST RESEARCH LABORATORY OREGON STATE UNIVERSITY. Information Reviewed and Reaffirmed. August No.

Installation, Operation and Maintenance Guide. Steam Coil Installation, Operation and Maintenance. steam coils

Economical and simplified solutions that offer quality and optimum steam trap service.

TYPE TESTING PROCEDURE FOR CRANKCASE EXPLOSION RELIEF VALVES JULY 2016

LABORATORY GLASSWARE WASHER MACHINE

FOUR-HOME-CEILING Ceiling Type Residential Heat Recovery Unit. is a registered trademark of Doğu İklimlendirme A.Ş.

Boiler Condensate Return Basics. Presented by Steve Connor February 24, 2016

Fire Pump Systems In Accordance With TS EN A2 Standard

APT and APT14 Automatic Pump Traps. for effective condensate drainage and removal

FOUR-FHR Counter Flow Heat Recovery Unit. is a registered trademark of Doğu İklimlendirme A.Ş.

Installation, Operation and Maintenance Instructions for Thermax Semi-Storage Calorifier

Main Steam Vents. Hoffman Specialty Regulators. How to Select Steam Vents

CRU-S Series Stainless Steel Condensate Recovery Unit

WHHR Midi & Midi Lite

Greenleaf 400 Macerator Toilet Waste Pump Instruction Manual

TEVHR. Heat Recovery Ventilators

Condensate Pumps Jones Boulevard Limerick Airport Business Center Pottstown PA Tel:

Blowdown Separator & Aftercoolers Installation, Operation, & Maintenance

BOILER HOUSE PRODUCTS GMS

Metropolitan. Steam Boiler. Suitable for Pressure Jet or Rotary Cup burners Oil, gas or dual fuel firing. Outputs kg/h

A complete, compact steam heat exchange solution for process and domestic water heating requirements.

Residential & Commercial Water Booster Systems Frequency Controlled Water Booster Systems

Safety. Connect the product properly to the ground. (Malfunctioning or power leaks can cause electrical shock.)

WOOD CHIP/PELLETS HEATING SYSTEMS

HIGH POWER. VICTRIX PRO 2 ErP. High power, wall-hung condensation boiler

Installation, Operation and Maintenance Instructions for Electric Storage Calorifier

INTRODUCTION THIS MANUAL INCLUDES IMPORTANT SAFETY INFORMATION

TEVHR. Heat Recovery Ventilators

Heat Recovery Units. Heat Recovery Units

Greenleaf 600 Macerator Toilet Waste Pump

Strategies in Optimizing Condensate Return

Model AV Alarm Valve With and Without Model RC-1 Retard Chamber European Conformity Valve Trim General Description

Turboboost SHOWER PUMPS. Installation Manual. 1.5 bar and 2.0 bar

Moss MOSS TRAY DEAERATOR ECONOMICAL INDUSTRIAL DEAERATOR SYSTEMS

Savile Plus. Steam Boiler. Suitable for Pressure Jet burners Oil, gas or dual fuel firing. Outputs kg/h

INSTALLATION AND OPERATION MANUAL

Efficient Steam System Design

Silhouette. Feedwater Heater. Boiler Feedwater

Steam Site Guide. Steam Site Guide. Heat Exchange Applications - SI Units

UNFIRED STEAM GENERATORS STANDARD EQUIPMENT

Installation Manual. Instrucciones de instalación y manual de usuario 1

Euron. Compact Wall Mounted Gas Fired Condensing Boilers and Combis with Outputs 24kW - 30kW BOILERS


Air Vents for Hot and Chilled Water Systems

13-1. Temperature Regulator

Product Data Sheet Refrigeration Dryer DFLO 66 (-W) bis DFLO 2400 (-W)

Boiler Steam Supply Piping Basics November 18, ) Q: What kind of condensate traps should be used on vacuum condensate return systems?

1 Exam Prep Solar Water and Pool Heating Manual (UCF) Questions and Answers (Plumbing Contractor)

Grades Prentice Hall. Fundamentals of HVAC/R HVACR High School ISBN's SE / IG Grades 9-12

VERTICAL HIGH OUTPUT VHC-IOM INSTALLATION AND MAINTENANCE INSTRUCTIONS VHC INSTALLER MUST BE A TRAINED, EXPERIENCED SERVICE TECHNICIAN

SECTION 50 - CAB CLIMATE CONTROL

INSTALLATION AND OPERATION MANUAL

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

SECTION HEATING BOILER FEEDWATER EQUIPMENT

VERTICAL TUBE HEATING COILS MV & VIFB MODELS

ANNEX 6. Refinery No. 1 New Area. Problems Existing in the Current Condensate Return System of the New Area of Refinery No.1

Steam: Yesterday, Today and Tomorrow The Use of Steam as an Efficient Heat Source

HYDRONIC SPECIALTIES TACO AC(F)-CA 05/08/2008

DMX fog machine User manual

Mitchell Metal Products, Inc.

ESCONDIDO FIRE DEPT TRAINING MANUAL Section Engine Module Page 1 of 8 Annual Sprinkler System Inspection Revised

Zip Hydroboil. Installation and Operating Instructions. Filtered instant boiling water

PCB-10 Condensate Recovery Systems

Industrial Evaporative Cooling Units

Installation, Operation and Maintenance Instructions for PlantPac Steam Plate Heat Exchanger Package

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-214(C) Series 61 Low Water Cut-Off OPERATION

Steam trap checking WHY WE NEED TO CHECK STEAM TRAPS METHODS OF CHECKING TRAPS ADVANTAGES AND DISADVANTAGES PRACTICAL DEMONSTRATION

Blowdown Separator & Aftercoolers

Transcription:

CONDANSATE TRANSFER PUMP info@ayvaz.com www.ayvaz.com

CONDANSATE TRANSFER PUMP Package Type Condansate Transfer Pump Ayvaz condensate pump is a system which is collecting how condensate and usually pump it for the using as a boiler feding water. Condensate pump can be work with gas, compressed air and steam. In high condesate situations, It can be usable double triple way. In systems if the boiler feed water is on optimum temperatures, system recover maximum energy because of this condensate pump has important role in systems. In system condensate pump use the electrical pumps using for the send high temperature condensate, but on that side flash steam make some cavitations. To avoid this situtation system use mechanic condensate pumps. Condensate Condensate Input Output A22 A1 A2 A4 A3 A5 A22 Buhar Girişi A9 A6 A8 A7 A11 A10 A17 Controller A16 A19 A15 A20 A18 Condensate Output A12 A13 A14 A21 A1/A2 Condansate Input A3 Condensate which is in between Steam Input and condensate pump A4 Flash steam and air release A5 Air Release A6 Manuel Valve A7 Pipe A8 Strainer A9 Steam Input A10 3 way Valve (Pneumatic) A11 Thermodynamic Steam trap A12/A14 Dısco Checkvalve A13 Drenaige A15 Air Filter and Pressure Reducer A16 Controller A17 Level Gauge (ELK-2) A18 Collector A19 Side supports A20 Condensate collection tank A21 Bottom table A22 Carriage parts Work Principles. Condensate comes from the input collector and goes on internal pipe and access check valve than enter in condesate pump body so tank is getting full. In tank when the condensate comes on the upper limit, ELK-2 leve gauge check the conductivity and change it to electrical signal and send it to 3 way pneumatic valve for the giving contact which is on the steam line than allows it to be opened. In normally steam has more high pressure than the condensate pressure. When 3 way valve is close, system discharge condensate from the system with thermodynamic steam trap. When the condensate pressure is smaller than the opposite pressure in condensate pump, discharge operation do not ocur. Steam is occurs the condensate discharging with entering the body, which have more pressure than the opposite pressure. When the condensate limit is gettin bottom limit of the tank, ELK-2 level gauge send electrical signal to 3-way pneumatic valve for close the system for entering steam. After that condens enter again and getting full tank. This operation frequency is connect between the condensate quantity.if the users want they can be follow the condensate quantity, from contoller.

Where does the condensate transfer pump using? 1- Temperature control processes which has temperature control valves (Pneumatic, electric actuators, thermodynamic etc. ) 2- Steam strap outputs 3- Between steam trap and condensate tanks which has long distance between themselves. 4- Low condensate pressure systems In heat exchangers after the steam traps That s why this situation getting more critical, ıf the condensate getting higher on steam traps outputs. On heat exchangers, when the temperature is going to be normal temperautes, control valve will be closed than steam volume drops and make some vacuums on serpantiles. There is no pressure for the condensate discharging. In that time condensate goes into the stable state and can t be discharging. This situation call STALL. This condensate goes on the heat systems and heat exchangers, makes some corrosion problems. That s why users condensate take into the some cap than discharge the condensate with the condensate transfer pump. There are many problems occurs if the systems don t use condensate transfer pump. Problems That Will Occur When The Condensate Pump Is Not Used 1- Corrosion 2- Product damages 3- Ram jam 4- Noises 5- Production loss because of the heat loss Advantages of using Condensate Transfer Pump 1- Recover condensate, water conservation 2- Decreases chemicals 3- Decreases fuel using 4- When using for the electrical pump, energy saves. 5- If using in electrical pumps, the problems does not occurs. 6- Pipe diameters don t increases 7- Unnesseary to using another condensate tank. Although in heat exchanger systems many control valves are using, if the steam is not equal or less than the steam after steam trap, discharging does not avaible. For this situation call condensate locks. With the condensate pump users can be prevent it. For choosing Condensate Pump 1- Steam ınput pressure which is using in condensate tank. (bar) 2- Opposite pressure (bar) (Line height, distance to condensate tank, elbow, valve, other condensate connection, condensate types etc. ) 3- Maximum pressure of heating process (bar ) 4- Steam capacitive (kg/h) 5- Lower limit of the heating fluids (Water sample etc.) ( C) 6- Maximum limit of the heating fluids (Water sample etc.) ( C)

Technical Properties ACOP ( Ayvaz Condensate Pump ) Input working Total Opposite 200i 300i 400i 500i 600i PRESSURE PRESSURE ACOP BAR KG/H 2 0.5 1190 2860 3790 5400 12285 1 1150 2550 3460 4520 11070 0.5 1260 3000 4080 5980 13770 3 1 1200 2770 3830 5100 12555 1.5 1170 2560 3600 4840 11745 2 1050 2320 3410 4350 10260 0.5 1300 3100 4290 6390 14850 1 1240 2920 4090 5510 13500 4 1.5 1200 2670 3790 5200 12285 2 1090 2460 3520 4570 11205 3 940 2090 2880 2810 10125 1 1270 3030 4290 5830 14175 5 1.5 1230 2760 3950 5480 12015 2 1130 2560 3600 4743 10935 3 980 2230 3040 3260 10800 1 1300 3130 4460 6090 14850 1.5 1250 2830 4070 5700 14040 6 2 1150 2650 3670 4880 12555 3 1020 2340 3170 3620 11475 4 990 1980 2630 3530 11340 1 1320 3210 4210 6310 15255 1.5 1270 2890 4170 5900 14445 7 2 1180 2720 3720 5000 13095 3 1050 2440 3280 3930 12015 4 1020 2030 2680 3630 11880 1 1340 3280 4320 6400 15795 1.5 1280 2940 4260 6070 14985 8 2 1200 2780 3770 5100 13500 3 1070 2520 3380 4200 12420 4 1040 2080 2720 3710 12285 1 1350 3340 4420 6510 16200 1.5 1290 2980 4340 6210 15390 9 2 1220 2840 3820 5190 13905 3 1100 2600 3460 4440 12825 4 1060 2120 2760 3780 12690 1 1370 3400 4510 6620 16470 1.5 1310 3020 4410 6340 15795 10 2 1230 2890 3850 5270 14310 3 1120 2660 3540 4647 13230 4 1080 2150 2800 3850 13095

Drawings Controller Desing Properties Collector design pressure bar (g) 3.5 Pump design pressure bar (g) 11 Design temperature C 187 Normal working conditions Condensate feed driving Max. Steam/Air Pressure bar (g) 10 Max. Steam temp. C 187 Pump discharge pressure bar (g) 5 Max. Supply voltage 230 V AC 1 phase 50 Hz Steam consumption 3 Kg Steam 1000 kg condensate Models and Connection Types Collector Pump MODEL Steam Collector Pump Draniage Steam Trap PUMP VENT Condensate Condensate ACOP Input (A9) VENT (A5) (A13) Line (A3) (A4) Input (A1, A2) Output (A14) ACOP200i DN50 X 2 DN25 DN15 DN50 DN25, SCR BSP DN15 DN15 ACOP300i DN50 X 2 DN40 DN15 DN50 DN25, SCR BSP DN15 DN15 ACOP400i DN50 X 2 DN50 DN15 DN80 DN25, SCR BSP DN15 DN15 ACOP500i DN50 X 2 DN80 DN15 DN80 DN25, SCR BSP DN15 DN15 ACOP600i DN80 X 2 DN100 DN15 DN100 DN25, SCR BSP DN15 DN25

Security Orders 1. Discharge If any carrying or lifting it must be supported. Please don t use the collector for carrying or hanging Please follow the instructions 2. Storage Please cover pump from sun and rain drops Please don t storage it in corositive placeses. Please don t smash crates Don t established it on the soil Crates life is almost 2-3 months. 3. Supply Pump must be establihes with RCC supply Supply table, is minimum 100 mm over the floor. For cleaning please drop 1 mm each units 4. Levels For water discharge, good drainage is must. 5. ACOP Position ACOP must be closer to system. Liquids direction must be the same direction with gravity. If the system is a flash steam application, output of the flash steam must have a distance minimum 500 mm from the collector. Without bending any of the collector discharge valve for evacuation to a safe place should be provided. For the prefering air, steam trap must be positioned on / off line. Pump discharging must be continious. Pump discharge pipe must be 3 times more than the condensate quantity. Steam, compressed air, single phase electrical connetion (230V AC, 50 Hz) etc.must be provided. For ACOP must be grounding. For control unit 1 KVA UPS is advising. The Installation Procedure 1. Connect the pump discharge line to directly boiler feed tank. 2. Please connect condensate line to collector and condensate pump. 3. Please pump drainage directly connect with the drainage chamber 4. Collector drainage line has correct angle. 5. 1 BSP Nipple hose always be ready in tow for the drainage. 6. When the pipe is open which is after the condensate pump, please apply low pressure air for examinate the discharge. 7. Please follow the drawings 8. 3 yollu vananın çalışması için, basınçlı havayı hava filtresi regülatörüne izolasyon vanası vasıtasıyla bağlayınız. 9. 230 V AC connection is must be same as instructions. 10. Please cover the supply cable from the moisture.

Commissioning 1. Open the power supply 2. Open the air valve and please sure about the pressure on the AFR. 3. Open the steam input valve. 4. For the first time, discharging the condensate from the stable line please use by-pass valves when steam is comming, please close by-pass valve 5. Open the butterfly valve 6. ACOP open valves on condensate line. 7. Open the condensate input valve full. 8. System on process now. Control & Safety 1. With the automatic leash assembly collector protected.otomatik bir l ile toplayıcı basınca karşı korunmuş olur. Selenoide valve must be protect with the emergcy safe button. 2. Main insurance protection is provided for the main feed. 3. The electrical supply is disconnected when air or condensate pump stops running. Stopping The Condensate Pump 1. Close the condensate valve 2. Open the by-pass line valve

Fixing Problems Problem CAUSE /CHECKING POINTS SOLVE Strainer clogging Clean Strainer Overflow Collector Input DCV closed or damaged If it is necessary please change it. Level gauge error Check Cables Power Unit Control Open, clean, If it is necessary please change it. Condensate overflow over the 3 way valve Selenoide valve error Change the coils. Release the connection points and change the 3 way valve. 3 way control valve error Knocking evacuation taking long i Leaking Clean try, if the problem will continue change the DVC 3 way valve opening valve Change the 3 way valve Steam coming from entry side of 3 way valve 3 way valve leaking Change the 3 way valve Less air pressure Not correct isolation Check the air pressure after regulator Check the isolation lines. Ram Jam No isolation on lines Diffrent assembly from instructions Kondens giriş&çıkış hattına eğim verilmemiştir. A lot of bendings in entry and output Flash tank steam trap is not working Apply Isolation Correct assemblies Apply correct angle for the system Please take minimum quantity for the bendings Check the steam trap and steam trap valve PROBLEMS WITH LEVEL GAUGES AND CONDUCTIVITIES Overflow levels Swithc doesn t working Main voltage not working. Heat Error Minimum conductivites There isn t any groundings Electronic card error Check the probs Ana akımı sağlayınız. Cihaz kablolamasını diyagrama uygun olarak tamamlayınız. Change the fuse DIPswitch (L) conductivity level must be > 0.5 PS/cm. Do Isolation Change it Change the assembly.

FACTORY Atatürk Sanayi Bölgesi Hadımköy Mahallesi Mustafa İnan Caddesi No: 44 Arnavutköy - İSTANBUL Tel: +90 212 771 01 45 (pbx) Faks: +90 212 771 47 27 info@ayvaz.com AREA OFFICES İSTANBUL Atatürk Sanayi Bölgesi Hadımköy Mahallesi Mustafa İnan Caddesi No: 44 Arnavutköy - İSTANBUL Tel: +90 212 771 01 45 (pbx) Fax: +90 212 771 25 60 Mobile: +90 530 404 71 67 satis@ayvaz.com ANKARA Şemsettin Günaltay Cad. No: 278/7 Kırkkonaklar Çankaya / ANKARA Tel: +90 312 446 72 96-97 Fax: +90 312 436 52 52 ankarabolge@ayvaz.com ANTALYA GSM: +90 530 404 71 66 antalyabolge@ayvaz.com BURSA Beşevler Mah. Aktaş Sok. Güleçler İş Mrk. No: 3 K: 2/8 Nilüfer/BURSA Tel: +90 224 256 97 45 Faks: +90 224 256 97 46 bursabolge@ayvaz.com GAZİANTEP Mücahitler Mah. 52054 No lu Sok. Güneydoğu İş Mrk. No: 10/49 GAZİANTEP Tel: +90 342 323 14 42 Fax: +90 342 323 14 43 GSM: +90 533 925 97 33 gaziantep@ayvaz.com ADANA Office: GSM: +90 533 925 98 28 adanabolge@ayvaz.com DİYARBAKIR Office : GSM: 0533 925 97 36 oaslan@ayvaz.com İZMİR 1348 Sokak Teknik Malzeme İş Mrk. Büro 305/319 Yenişehir Konak / İZMİR Tel: +90 232 459 12 48 Fax: +90 232 459 42 36 izmirbolge@ayvaz.com BLACKSEA : GSM: +90 530 404 71 68 karadenizbolge@ayvaz.com KOCAELİ GSM: +90 530 512 18 38 kocaeli@ayvaz.com TRAKYA GSM: +90 530 568 25 85 trakya@ayvaz.com Caserta/Italy Tel: +39 0823 187 3988 rmolaro@ayvaz.com Kiev/Ukraine Tel: +380 44 390 57 57 info@ayvaz.com.ua Moscow/Russia Tel: +74959951728 ayvazrus@ayvaz.com Sao Paulo/Brazil Tel: +551 194 500 4123 brazil@ayvaz.com Viernheim/Germany Tel: +49 62046014399 germany@ayvaz.com Dubai /U.A.E Tel: +971 48808671 +971 501306871 mideast@ayvaz.com