Study of Behavior of Refrigerant Mixtures in Domestic Refrigerator- Practical Research

Similar documents
Pure Butane as Refrigerant in Domestic Refrigerator Freezer

BUTANE, ISOBUTANE AND THEIR MIXTURES AS AN ALTERANTIVES TO R-134a IN DOMESTIC REFRIGERATOR

Performance Investigation of Domestic Refrigerator Using Pure Hydrocarbons and Blends of Hydrocarbons as Refrigerants

International Journal of Multidisciplinary Research and Modern Education (IJMRME) ISSN (Online): (

PERFORMANCE OF DEEP FREEZER BY USING HYDROCARBON BLENDS AS REFRIGERANTS

Experimental Evaluation of Refrigerant Mixtures as Substitutes for HFC134a

Experimental study of Hydrocarbon Refrigerant Mixture R290/R600a as an alternative to Refrigerant R134a used in a Domestic Refrigerator

Assessment of LPG as a possible alternative to R-12 in domestic refrigerators

Design of LPG Refrigeration System

Effects of evaporator load on vapour compression refrigeration system using ecofriendly hydrocarbon refrigerants with sub cooling

Part load performance analysis of vapour compression refrigeration system with hydrocarbon refrigerants

DEEPAK PALIWAL, S.P.S.RAJPUT

Main Anthropogenic Sources of Greenhouse Gases Refrigerants

EVALUATION OF REFRIGERANT R290 AS A REPLACEMENT TO R22

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

ASSESSMENT OF R430A REFRIGERANT AS A POSSIBLE SUBSTITUTE TO R134A REFRIGERANT IN LARGE CAPACITY FREEZER

Improving and Comparing the Coefficient of Performance of Domestic Refgirator by using Refrigerants R134a and R600a

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

Design and Fabrication of Liquefied Petroleum Gas Refrigeration System and Comparison with Domestic Refrigerator

CHAPTER 1 INTRODUCTION

Department of MCE, Islamic University of Technology 2. Abstract

Experimental Study on Performance Parameters for Refrigerants R22, R410a and R404a at Various Air Outlet Temperatures

Australian Journal of Basic and Applied Sciences. Investigation of New Eco Friendly Refrigerant Mixture Alternative to R134a in Domestic Refrigerator

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid

Comparative Performance Analysis of Domestic Refrigerator using R12, R134a and R600a Refrigerants

IJISET - International Journal of Innovative Science, Engineering & Technology, Vol. 2 Issue 12, December

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview

CH2351 Chemical Engineering Thermodynamics II Unit V Refrigeration. Dr. M. Subramanian

CHAPTER 1 INTRODUCTION

A Review of Hydroflorocarbons (HFC S) Refrigerants as an Alternative to R134a Refrigerant

ISSN Electronic International Interdisciplinary Research Journal (EIIRJ) Bi-monthly Reviewed Journal Mar- April 2015

FABRICATION OF REFRIGERANT FLOW RATE WITH SPIRALLY COILED CAPILLARY TUBE

LPG Refrigerator. October 2017 IJIRT Volume 4 Issue 5 ISSN:

Refrigeration Cycles MOHAMMAD FAISAL HAIDER. Bangladesh University of Engineering and Technology

Oyelami S., Bolaji B. O.

Evaluation of Vapour Compression Refrigeration System Using Different Refrigerants

EXPERIMENTAL INVESTIGATION OF WATER COOLER SYSTEM BY USING ECO-FRIENDLY REFRIGERANT (R-134a)

THEORETICAL INVESTIGATION OF THE PERFORMANCE OF SOME ENVIRONMENT-FRIENDLY REFRIGERANTS IN A SUB-COOLING HEAT EXCHANGER REFRIGERATION SYSTEM

Study of R-161 refrigerant as an Alternate Refrigerant to various other refrigerants

Effect of capillary diameter on the power consumption of VCRS using different refrigerants

International Journal of Advance Engineering and Research Development

A Theoretical investigation on HC Mixtures as Possible Alternatives to R134a in Vapor Compression Refrigeration

Performance Analysis of Electronic Expansion Valve in 1 TR Window Air Conditioner using Various Refrigerants

Experimental study of R600a and R436a to replace R134a in a domestic refrigerator and freezer

A Review Paper on Comparative Study of Household- Refrigerator with Alternative Low Global Warming Potential Refrigerants

Enhancement of COP using Nanoadditives in Domestic Refrigerator

STUDY AND PERFORMANCE ANALYSIS OF ECO-FRIENDLY REFRIGERANT FOR RETROFITTING R22 IN RESPECT TO BANGLADESH

Performance Analysis of Li-Br Water Refrigeration System with Double Coil Anti-Swirl Shell and Coil Heat Exchangers

FABRICATION SOLAR REFRIGERATION SYSTEM BY PELTIER EFFECT

REPLACING HARMFUL CFC 12 BY ECO-FRIENDLY REFRIGERANT IN MILK CHILLER

HFC/HC BLEND FOR CAR CLIMATE CONTROL WITH MINERAL OIL AS LUBRICANT

WORK STUDY ON LOW TEMPERATURE (CASCADE) REFRIGERATION SYSTEM

Volume 3, Issue 4 (2015) ISSN International Journal of Advance Research and Innovation

International Journal of Research in Engineering and Innovation Vol-1, Issue-5 (2017), 68-72

Thermodynamics I. Refrigeration and Heat Pump Cycles

Refrigerants Type Expensive Coefficient of Performance Toxic

Thermodynamic study of R134a in Vapour Compression Refrigeration System in Summer Climate

A Comparison Between Refrigerants Used In Air Conditioning

Enhancing the performance of the domestic refrigerator with hot gas injection to suction line

EXPERIMENTAL INVESTIGATIONS ON AUTOMOBILE AIR CONDITIONERS WORKING WITH R134a AND R290/R600a AS AN ALTERNATIVE

Use of fourth generation ecofriendly refrigerants in two and three cascade refrigeration systems for reducing global warming and ozone depletion

Paper No. : 04 Paper Title : Unit Operations in Food processing Module 11 : Principles of Refrigeration

PERFORMANCE OF REFRIGERATOR USING R-600A AS REFRIGERANT

International Engineering Research Journal (IERJ) Special Issue Page , June 2016, ISSN

Comparative assessment for drop in replacement of R134a in domestic refrigerator.

Thermodynamics II Chapter 5 Refrigeration

Refrigerants Retrofit as Alternative for R12 and R134a in Household Refrigerators

中国科技论文在线 Energy Conversion and Management 52 (2011)

Performance of an Improved Household Refrigerator/Freezer

PERFORMANCE OF A VERY LOW TEMPERATURE REFRIGERATION SYSTEM OPERATING WITH NATURAL FLUIDS

Pressure drop analysis of evaporator using refrigerants R-22, R-404A and R-407C

A Review on selecting an Eco-friendly Refrigerant alternate to R134a in Domestic Refrigerators

EXPERIMENTAL INVESTIGATION OF A REFRIGERATOR BY USING ALTERNATIVE ECO FRIENDLY REFRIGERANTS (R600A & HC MIXTURE)

An Investigation Into The Influence Of Improved Refrigeration Cycle And Refrigerants On An Energy Efficient Domestic Refrigerator

IR-REVERSIBILITY ANALYSIS OF A SPLIT TYPE AIRCONDITIONER USING R600a AS REFRIGERANT

An Experimental Study of a Simple Vapour Compression Refrigeration System with Varying Parameters

Study of Performance of Binary Mixture of R134a and R161 as a Substitution of R134a in a Domestic Refrigerator

Analysis of Vapour Compression Refrigeration System with Refrigerants R134a, R143a, R152a, R290 and R32

Chapter 10. Refrigeration and Heat Pump Systems

14. The center port of the manifold is used for evacuation, charging and refrigerant recovery.

Performance Study of Geotropic Blends of Isobutane R600a and Propane R290 in Domestic Refrigerator as Alternative Refrigerants to R134a

Technology Application of Environmental Friendly Refrigeration (Green Refrigeration) on Cold Storage for Fishery Industry

Experimentation and Fabrication of Iceplant Using Ecofriendly Refrigerant

Experimental performance evaluation of vapour compression refrigeration system without nano particles

Volume 6, Issue 3(2018) ISSN International Journal of Advance Research and Innovation

Available online at ScienceDirect. Energy Procedia 109 (2017 ) 56 63

EFFECT OF DIVERSE STREAM PATTERNS ON THE PERFORMANCE OF SOLAR AIR HEATER

RS-70 is suitable as a direct replacement for R-22 in low, medium and high temperatures in a great number of applications:

Sarthak Thakar, 2 R.P.Prajapati 1

AN EXPERIMENTAL STUDY OF A REFRIGERATING PLANT WHEN REPLACING R22 WITH HFCs REFRIGERANTS

Experimental Investigation on R 290 and R 600a In a Vapor Compression Refrigeration

Fabrication of Hot and Cold Water Dispenser

Heat Transfer Analysis of Vapor Compression System Using Nano Cuo-R134a

Volume 4, Issue 1 (2016) ISSN International Journal of Advance Research and Innovation

U.G. Student, Department of Mechanical Engineering, J D Engineering College, Nagpur, Maharashtra, India

Assessment of Alternatives to Refrigerant R134a in Automotive Air Conditioning System

Design and Fabrication of Water Refrigeration System by Creating Vacuum

Performance and Analytical Study of Cooler Cum Air Conditioner based on Vapour Compression Refrigeration System

Performance Evaluation of Eco- Friendly Alternate Refrigerants for VCRS

HFCs or the Old Refrigerants - what is the best Choice?

Transcription:

International Journal of Engineering Trends and Applications (IJETA) Volume 5 Issue, Nov-Dec 201 RESEARCH ARTICLE Study of Behavior of Refrigerant Mixtures in Domestic Refrigerator- Practical Research K. Arumuganainar [1], P. Ramesh [2], R. Ramaswamy [3] [1], [2] & [3] Assistant Professor Department of Automobile Engineering Ponjesly college of Engineering, Nagercoil Tamil Nadu OPEN ACCESS ABSTRACT In this investigation, a domestic refrigerator was designed to work with R-134a and the possibility of using mixed refrigerants. The effect of condenser temperature and evaporator temperature on, refrigerating effect was investigated. The energy consumption of the refrigerator during experiment with mixed refrigerant and R-134a was measured. The results shows the continuous running and cycling results showed that with a charge of 0 g or mixed refrigerant with charge of 0 mg or more satisfy the required freezer air temperature of 12 C. The lowest electric energy consumption was achieved using mixed refrigerant with temperature level is less than -15 o C. This combination achieved higher volumetric cooling capacity and lower freezer air temperature compared to R-134a. Experimental results of the refrigerator using mixed refrigerant were compared with those using. Pull-down time, pressure ratio and power consumption of mixed refrigerant refrigerator were lower than those of refrigerator by about.%, 5.5% and 4.3%, respectively. Also, actual of mixed refrigerant refrigerator was higher than that of R-134a by about.%. Lower on-time ratio and energy consumption of mixed refrigerant refrigerator is nearly 14.3% and.%, respectively, compared to those of R-134a refrigerator were achieved. The and other result obtained in this experiment show a positive indication of using mixed refrigerant as refrigerants in domestic refrigerator. Keywords : Chlorofluorocarbons (CFCs), Butane, Hydrocarbons Iso-butane and Energy consumption, R-134a I. INTRODUCTION Natural ice was harvested, distributed and used in both commercial and home applications in the mid-0s to refrigerate food. The idea that cold could be produced by the forced evaporation of a volatile liquid under reduced pressure had been previously pursued by William Cullen in the eighteenth century. A refrigerator (often called a "fridge" for short) is a cooling appliance comprising a thermally insulated compartment and a heat pump - chemical or mechanical means - to transfer heat from it to the external environment, the contents to a temperature below ambient. Refrigerators are extensively used to store foods which deteriorate at ambient temperatures; spoilage from bacterial growth and other processes is much slower at low temperatures. A device described as a "refrigerator" maintains a temperature a few degrees above the freezing point of water; a similar device which maintains a temperature below the freezing point of water is called a "freezer." The refrigerator is a relatively modern invention among kitchen appliances. It replaced the icebox, which had been a common household appliance for almost a century and a half prior. For this reason, a refrigerator is sometimes referred to as an "ice box". Freezers keep their contents frozen. They are used in households and in industry and commerce. Most freezers operate around -1 C (0 F). Domestic freezers can be included as a separate compartment in a refrigerator, or can be a separate appliance. Domestic freezers are generally upright units resembling refrigerators, or chests resembling upright units lay on their backs. Many upright modern freezers come with an ice dispenser built into their door. Chlorofluorocarbons (CFCs) and hydro chlorofluorocarbons (HCFCs) have many suitable properties, for example, non flammability, low toxicity and material compatibility that have led to their common widespread use by both consumers and industries around the world, especially as refrigerants in air conditioning and refrigerating systems. Results from many researches show that this ozone layer is being depleted. The general consensus for the cause of this event is that free chlorine radicals remove ozone from the atmosphere, and later, chlorine atoms continue to convert more ozone to oxygen. The presence of chlorine in the stratosphere is the result of the migration of chlorine containing chemicals. The chlorofluorocarbons (CFCs) and hydro chlorofluorocarbons (HCFCs) are a large class of chemicals that behave in this manner. Since the discovery of the depletion of the earth s ozone layer caused mainly by CFC and HCFC and as a result ISSN: 233-51 www.ijetajournal.org Page 30

International Journal of Engineering Trends and Applications (IJETA) Volume 5 Issue, Nov-Dec 201 of the 12 United Nations Environment Program meeting, the phase out of CFC-11 and CFC-12, used mainly in conventional refrigeration and air conditioning equipment, was expected by 1 (Lee and Su, 2002). The thermo physical properties of HFC-134a are very similar to those of CFC-12 and are also non-toxic environmentally safe refrigerant; the American Household Appliances Manufacturers have recommended HFC-134a as a potential replacement for CFC-12 in domestic refrigerators. However, while the ozone depletion potentials of HFC-134a relative to CFC-11 are very low, the global warming potentials are extremely high and also expensive. For this reason, the production and use of HFC- 134a will be terminated in the near future (Tashtoush et al., 2002, Sekhar et al., 2005, Somchai and Nares, 2005). Hydrocarbon especially propane, butane and isobutene are proposed as an environment benign refrigerant. Hydrocarbons are free from ozone depletion potential and have negligible global warming potential. Lee and Su (2002) conducted an experiment study on the use of isobutene as refrigerant in domestic refrigerator. The performance was comparable with those of CFC-12 and HCFC-22 was used as refrigerant. Commercial fridge and freezer units, which go by many other names, were in use for almost 40 years prior to the common home models. They used toxic gas systems, which occasionally leaked, making them unsafe for home use. Practical household refrigerators were introduced in 115 and gained wider acceptance in the United States in the 130s as prices fell and non-toxic, non-flammable synthetic refrigerants such as Freon or R-12 were introduced. It is notable that while 0% of households in the US owned a refrigerator by the 130s, it was not until 40 years later, in the 10s, that the refrigerator achieved a similar level of penetration in the UK. Refrigerant selection involves balancing conflicting requirements such as: ability to transfer heat, chemical stability, and compatibility with compressor lubricants, flammability, and toxicity. Akash and Said (2003) studied the performance of mixed refrigerant from local market (30%propane, 55% n-butane and 15% isobutene by mass) as an alternative refrigerant for CFC-12 in domestic refrigerator with masses of 50g, 0g and 0g. The result showed that a mass charge of 0g gave the best performance. Scientist and researcher are searching the environment benign refrigerant for the domestic refrigerator and freezer. Finally we decide to choose the mixed refrigerant as an alternate source of HFC- 134. II. EXPERIMENTAL SETUP AND TEST PROCEDURE This section provides a description of the facilities developed for conducting experimental work on a domestic refrigerator. The technique of charging and evacuation of the system is also discussed here. Experimental data collection was carried out in the research laboratory of our institution. The schematic diagram of the test unit and apparatus is shown in the Fig. 1.Experimental Methodology The schematic diagram of the domestic refrigerator used in the experiment is shown in Fig 1. The domestic refrigerator consists of an evaporator, wire mesh air-cooled condenser and hermetically sealed reciprocating compressor. The 15 liters domestic refrigerator of tropical class originally designed to work with HFC134a was taken for this study. The refrigerator was instrumented with one pressure gauge at the inlet of the compressor for measuring the suction pressure, one temperature sensor mounted at inside the refrigerator (freezer) compartment. As per the refrigerator manufactures recommendation quantity of charge requirement for HFC134a was 0 g. In the experiment, refrigerant charge is % higher due to the presence of instruments and connecting lines etc. To optimize the mixed refrigerant charge, the refrigerator is charged with 0g. The refrigerator was charged with 1 g of HFC134a and the base line performance was studied. After completing the base line test with HFC134a, the refrigerant was recovered from the system and charged with 0g of mixed refrigerant and the performance was studied. The refrigerant charge requirement with hydrocarbons is very small due to their higher latent heat of vaporization. During the experimentation the atmospheric temperature is maintained at 2 ± 2 o C. The experimental procedures were repeated and readings from the various modes were taken. Service port is installed at the inlet of expansion valve and compressor for charging and recovering the refrigerant is shown in the Figure 1. Digital Temperature Indicator was used to measure the inside freezer temperature. ISSN: 233-51 www.ijetajournal.org Page 31

International Journal of Engineering Trends and Applications (IJETA) Volume 5 Issue, Nov-Dec 201 entire refrigerants have evaporated and only vapor refrigerant remains in the evaporator coil. The liquid refrigerant still colder than the medium being cooled, therefore the vapor refrigerants continue to absorb heat. The experiment was performed on the domestic refrigerator purchased from the market, the components of the refrigerator was not changed or modified. This indicates the possibility of using mixed refrigerant as an alternative of HFC-134a in the existing refrigerator system. The of the domestic refrigerator using R-134a as a refrigerant was considered as benchmark and the of mixed refrigerant compared. The time versus is plotted at the refrigerant R-134a and mixed refrigerant (without load & different mode) in the same graph. The results displayed in Figs. 2, 3, 4 and 5 shows a progressive increase in as the temperature varies. Mode 1 Time Vs (Without Load) Fig. 1 Investigation Unit And Apparatus A. Test Procedure The system was evacuated with the help of vacuum pump to remove the moisture and charged with the help of charging system. The temperature inside the chamber was maintained at 25 C and 2 C. When the temperature and humidity inside the chamber was at steady state, the experiments were started. The experiment has been conducted on the domestic refrigerator at no load and closed door conditions. III.RESULTS AND DISCUSSIONS Fig 2 Mode 1 Time Vs (Without Load) Mode 2 Time Vs (Without Load) From this section the comparison of the performance parameter of the refrigerants and energy consumption by the refrigerator was discussed. This investigation deals with mixed refrigerant (hydrocarbon mixtures of propane, butane and isobutane) in order to assess their feasibility for replacing HFC-134a in refrigeration systems by comparing their relevant parameters. The refrigerating effect is the main purposes of the refrigeration system. The liquid refrigerant at low pressure side enters the evaporator. As the liquid refrigerant passes through the evaporator coil, it continually absorbs heat through the coil walls, from the medium being cooled. During this, the refrigerant continues to boil and evaporate. Finally the Fig 3 Mode 2 Time Vs (Without Load) ISSN: 233-51 www.ijetajournal.org Page 32

International Journal of Engineering Trends and Applications (IJETA) Volume 5 Issue, Nov-Dec 201 Mode 2 Time Vs (With Load) Mode 3 Time Vs (Without Load).5.5.5.5.25.5.5.25 Mixed refrigerant Fig 4 Mode 3 Time Vs (Without Load) Fig Mode 2 Time Vs (With Load).5.5 5.5 5 Mode 4 Time Vs (Without Load).5.5 Mode 3 Time Vs (With Load) Fig 5 Mode 4 Time Vs (Without Load) Fig Mode 1 Time Vs (With Load) The time versus is plotted at the refrigerant and mixed refrigerant (without & different mode) in the same graph. The results displayed in Figs.,, and shows a progressive increase in as the temperature varies. Mode 1 Time Vs (With Load).5.5 5.5 5 Mode 4 Time Vs (With Load) Fig Mode 4 Time Vs (With Load) Fig Mode 1 Time Vs (With Load) ISSN: 233-51 www.ijetajournal.org Page 33

International Journal of Engineering Trends and Applications (IJETA) Volume 5 Issue, Nov-Dec 201 IV. CONCLUSION This Project work was investigated in an ozone friendly, energy efficient, user friendly, safe and cost-effective alternative refrigerant for HFC134a in domestic refrigeration systems. After the successful investigation on the performance of mixed refrigerants the following conclusions can be drawn based on the results obtained. This experimental investigation carried out to determine the performance of a domestic refrigerator when a propane/butane mixture is used as a possible replacement to the traditional refrigerant. The used mixed refrigerant is locally available and comprises 24.4% propane, 5.4% butane and 1.2% iso-butane. The performance parameters investigated are the refrigeration capacity, the evaporator temperature and the coefficient of performance (). The refrigerator worked efficiently when mixed refrigerant was used as refrigerant instead of. The evaporator temperature reached -20 C with value of.4 and an ambient temperature of 30 C. The results of the present work indicate the successful use of this LPG (propane/butane mixture) as an alternative refrigerant to in domestic refrigerators. The co-efficient of performance for the LPG is comparable with the co-efficient of performance of HFC- 134a. The domestic refrigerator was charged with 140g of HFC-134a and 0g of mixed refrigerant. This is an indication of better performance of mixed refrigerant as refrigerants. The following conclusions can be elicited from our investigation 1. Every mode of mixed refrigerant yields higher than HFC-134a. 2. From using the mixed refrigerant in domestic refrigerator, we have observed the freezer temperature lower than that of the. 3. When the evaporator temperature increases, will increases and when the condenser temperature decreases, will also increase. REFERENCES [1] R. Radermacher, K. Kim, Domestic refrigerator: recent development, International journal of refrigeration 1(1) 1-. [2] B. A.Akash, S.A. Said, Assessment of LPG as a possible alternative to R-12 in domestic refrigerators. Energy conversion and Management 44 (2003) 31-3. [3] B. Tashtoush, M. Tahat, M. A. Shudeifat. Experiment study of new refrigerant mixtures to replace R12 in domestic refrigerator. Applied Thermal Engineering 22 (2002) 45-50. [4] S. Devotta, A. V. Wagmare, N. N. Sawant, B.M. Domkundwar, Alternatives to HFC-22 for air conditioners, Applied Thermal Engineering 21(2001) 03-15. [5] Joseph Sekhar, D.Mohan Lal, S. Renga narayanan, Improved energy efficiency for CFC domestic refrigerators with ozone-friendly HFC134a/HC refrigerant mixture, International Journal of thermal Science 43(2004) 30-314. [] United Nations Environment Programme. (11) Study on the Potential for Hydrocarbon Replacements in Existing Domestic and Small Commercial Refrigeration Appliances. United Nations Publication ISBN 2-0- 15-0. [] Jung D, Kim CB, Song K, Park B. Testing of propane/isobutane mixture in domestic refrigerators. Int. J Refrig. 2000;23():51-52. [] Inan C, Gonul T, Tanes MY. X-ray investigation of a domestic refrigerator. Observations at 25 C ambient temperature. Int. J Refrig. 2003;2(2):205-213. [] Khurmi, R.S. (2012). Refrigeration & Air-Conditioning th ed. New Delhi: S. Chand. [] Y. Fan, L. Luo, B. Souyri. (200). Review of solar sorption refrigeration technologies: Development and applications. ELSEVIER, 15-15. [11] Uppal AH, Norton B, Probert SD. A low-cost solarenergy stimulated absorption refrigerator for vaccine storage. Applied Energy 1;25:1 4. [12] Sierra FZ, Best R, Holland FA. Experiments on an absorption refrigeration system powered by a solar pond Heat Recovery System CHP 13;13:401. [13] Anyanwu EE, Ezekwe CI. Design, construction and test run ofasolidabsorption solar refrigerator using activated carbon/methanol, as working fluid pair. Energy Conversion Manage 2003;44:2 2. [14] Critoph RE. Rapid cycling solar/biomass powered adsorption refrigeration system. Renewable Energy 1;1:3. ISSN: 233-51 www.ijetajournal.org Page 34